1
|
Wang H, Zhang C, Wang Y, Zeng Y, Chen S, Su X, Li W, Yu M, Chen D. Biomechanical analysis of spinal cord injury during scoliosis correction surgery. Front Bioeng Biotechnol 2024; 12:1399691. [PMID: 39015138 PMCID: PMC11249739 DOI: 10.3389/fbioe.2024.1399691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 06/11/2024] [Indexed: 07/18/2024] Open
Abstract
Introduction: Surgical correction is a common treatment for severe scoliosis. Due to the significant spinal deformation that occurs with this condition, spinal cord injuries during corrective surgery can occur, sometimes leading to paralysis. Methods: Such events are associated with biomechanical changes in the spinal cord during surgery, however, their underlying mechanisms are not well understood. Six patient-specific cases of scoliosis either with or without spinal complications were examined. Finite element analyses (FEA) were performed to assess the dynamic changes and stress distribution of spinal cords after surgical correction. The FEA method is a numerical technique that simplifies problem solving by replacing complex problem solving with simplified numerical computations. Results: In four patients with poor prognosis, there was a concentration of stress in the spinal cord. The predicted spinal cord injury areas in this study were consistent with the clinical manifestations of the patients. In two patients with good prognosis, the stress distribution in the spinal cord models was uniform, and they showed no abnormal clinical manifestations postoperatively. Discussion: This study identified a potential biomechanical mechanism of spinal cord injury caused by surgical correction of scoliosis. Numerical prediction of postoperative spinal cord stress distribution might improve surgical planning and avoid complications.
Collapse
Affiliation(s)
- Haimei Wang
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Chunyu Zhang
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Yongqiang Wang
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
| | - Yan Zeng
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
| | - Songhao Chen
- College of Engineering, Peking University, Beijing, China
| | - Xingyu Su
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| | - Weishi Li
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
| | - Miao Yu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
| | - Duanduan Chen
- School of Medical Technology, Beijing Institute of Technology, Beijing, China
| |
Collapse
|
2
|
Park JS, Goh TS, Lee JS, Lee C. Analyzing isolated degeneration of lumbar facet joints: implications for degenerative instability and lumbar biomechanics using finite element analysis. Front Bioeng Biotechnol 2024; 12:1294658. [PMID: 38600941 PMCID: PMC11005061 DOI: 10.3389/fbioe.2024.1294658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 02/26/2024] [Indexed: 04/12/2024] Open
Abstract
The facet joint contributes to lumbar spine stability as it supports the weight of body along with the intervertebral discs. However, most studies on the causes of degenerative lumbar diseases focus on the intervertebral discs and often overlook the facet joints. This study aimed to investigate the impact of facet joint degeneration on the degenerative changes and diseases of the lumbar spine. A finite element model of the lumbar spine (L1-S1) was fabricated and validated to study the biomechanical characteristics of the facet joints. To simulate degeneration of the facet joint, the model was divided into four grades based on the number of degenerative segments (L4-L5 or L4-S1) and the contact condition between the facet joint surfaces. Finite element analysis was performed on four spine motions: flexion, extension, lateral bending, and axial torsion, by applying a pure moment to the upper surface of L1. Important parameters that could be used to confirm the effect of facet joint degeneration on the lumbar spine were calculated, including the range of motion (ROM) of the lumbar segments, maximum von Mises stress on the intervertebral discs, and reaction force at the facet joint. Facet joint degeneration affected the biomechanical characteristics of the lumbar spine depending on the movements of the spine. When analyzed by dividing it into degenerative onset and onset-adjacent segments, lumbar ROM and the maximum von Mises stress of the intervertebral discs decreased as the degree of degeneration increased in the degenerative onset segments. The reaction force at the facet joint decreased with flexion and increased with lateral bending and axial torsion. In contrast, lumbar ROM of the onset-adjacent segments remained almost unchanged despite severe degeneration of the facet joint, and the maximum von Mises stress of the intervertebral discs increased with flexion and extension but decreased with lateral bending and axial torsion. Additionally, the facet joint reaction force increased with extension, lateral bending, and axial rotation. This analysis, which combined the ROM of the lumbar segment, maximum von Mises stress on the intervertebral disc, and facet joint reaction force, confirmed the biomechanical changes in the lumbar spine due to the degeneration of isolated facet joints under the load of spinal motion. In the degenerative onset segment, spinal instability decreased, whereas in the onset-adjacent segment, a greater load was applied than in the intact state. When conducting biomechanical studies on the lumbar spine, considering facet joint degeneration is important since it can lead to degenerative spinal diseases, including adjacent segment diseases.
Collapse
Affiliation(s)
- Jun Sung Park
- Department of Biomedical Engineering, Graduate School, Pusan National University, Busan, Republic of Korea
| | - Tae Sik Goh
- Department of Orthopaedic Surgery, School of Medicine, Pusan National University, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Jung Sub Lee
- Department of Orthopaedic Surgery, School of Medicine, Pusan National University, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Chiseung Lee
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
- Department of Biomedical Engineering, School of Medicine, Pusan National University, Busan, Republic of Korea
| |
Collapse
|
3
|
Vedantam A, Harinathan B, Purushothaman Y, Scripp S, Banerjee A, Warraich A, Budde MD, Yoganandan N. Determinants of spinal cord stress and strain in degenerative cervical myelopathy: a patient-specific finite element study. Biomech Model Mechanobiol 2023; 22:1789-1799. [PMID: 37306885 DOI: 10.1007/s10237-023-01732-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 05/29/2023] [Indexed: 06/13/2023]
Abstract
Degenerative cervical myelopathy (DCM) is the commonest cause of spinal cord dysfunction in older adults and is characterized by chronic cervical spinal cord compression. Spinal cord stress and strain during neck motion are also known contributors to the pathophysiology of DCM, yet these factors are not routinely assessed for surgical planning. The aim of this study was to measure spinal cord stress/strain in DCM using patient-specific 3D finite element models (FEMs) and determine whether spinal cord compression is the primary determinant of spinal cord stress/strain. Three-dimensional patient-specific FEMs were created for six DCM patients (mild [n = 2], moderate [n = 2] and severe [n = 2]). Flexion and extension of the cervical spine were simulated with a pure moment load of 2 Nm. Segmental spinal cord von Mises stress and maximum principal strain were measured. Measures of spinal cord compression and segmental range of motion (ROM) were included in a regression analysis to determine associations with spinal cord stress and strain. Segmental ROM in flexion-extension and axial rotation was independently associated with spinal cord stress (p < 0.001) and strain (p < 0.001), respectively. This relationship was not seen for lateral bending. Segmental ROM had a stronger association with spinal stress and strain as compared to spinal cord compression. Compared to the severity of spinal cord compression, segmental ROM is a stronger determinant spinal cord stress and strain. Surgical procedures that address segmental ROM in addition to cord compression may best optimize spinal cord biomechanics in DCM.
Collapse
Affiliation(s)
- Aditya Vedantam
- Department of Neurosurgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
| | - Balaji Harinathan
- Department of Neurosurgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| | - Yuvaraj Purushothaman
- Department of Neurosurgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| | - Stephen Scripp
- Biomedical Engineering, Milwaukee School of Engineering, Milwaukee, WI, USA
| | - Anjishnu Banerjee
- Department of Biostatistics, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Ali Warraich
- Department of Chemistry, University of Chicago, Chicago, IL, USA
| | - Matthew D Budde
- Department of Neurosurgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| | - Narayan Yoganandan
- Department of Neurosurgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| |
Collapse
|
4
|
Shang P, Ma B, Hou G, Zhang Y, Cui L, Song W, Liu Y. A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement. J Orthop Surg Res 2023; 18:828. [PMID: 37924130 PMCID: PMC10623881 DOI: 10.1186/s13018-023-04310-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Prosthesis subsidence and mechanical failure were considered significant threats after vertebral body replacement during the long-term follow-up. Therefore, improving and optimizing the structure of vertebral substitutes for exceptional performance has become a pivotal challenge in spinal reconstruction. METHODS The study aimed to develop a novel artificial vertebral implant (AVI) with triply periodic minimal surface Gyroid porous structures to enhance the safety and stability of prostheses. The biomechanical performance of AVIs under different loading conditions was analyzed using the finite element method. These implants were fabricated using selective laser melting technology and evaluated through static compression and subsidence experiments. RESULTS The results demonstrated that the peak stress in the Gyroid porous AVI was consistently lower than that in the traditional porous AVI under all loading conditions, with a maximum reduction of 73.4%. Additionally, it effectively reduced peak stress at the bone-implant interface of the vertebrae. Static compression experiments demonstrated that the Gyroid porous AVI was about 1.63 times to traditional porous AVI in terms of the maximum compression load, indicating that Gyroid porous AVI could meet the safety requirement. Furthermore, static subsidence experiments revealed that the subsidence tendency of Gyroid porous AVI in polyurethane foam (simulated cancellous bone) was approximately 15.7% lower than that of traditional porous AVI. CONCLUSIONS The Gyroid porous AVI exhibited higher compressive strength and lower subsidence tendency than the strut-based traditional porous AVI, indicating it may be a promising substitute for spinal reconstruction.
Collapse
Affiliation(s)
- Peng Shang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China.
| | - Benyuan Ma
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Guanghui Hou
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yihai Zhang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Lunxu Cui
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Wanzhen Song
- School of Mechanical Engineering, Hebei University of Technology, Tianjin, China
| | - Yancheng Liu
- Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
| |
Collapse
|
5
|
Muhayudin NA, Basaruddin KS, Ijaz MF, Daud R. Finite Element Modelling of a Synthetic Paediatric Spine for Biomechanical Investigation. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4514. [PMID: 37444827 DOI: 10.3390/ma16134514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/31/2023] [Accepted: 06/09/2023] [Indexed: 07/15/2023]
Abstract
Studies on paediatric spines commonly use human adult or immature porcine spines as specimens, because it is difficult to obtain actual paediatric specimens. There are quite obvious differences, such as geometry, size, bone morphology, and orientation of facet joint for these specimens, compared to paediatric spine. Hence, development of synthetic models that can behave similarly to actual paediatric spines, particularly in term of range of motion (ROM), could provide a significant contribution for paediatric spine research. This study aims to develop a synthetic paediatric spine using finite element modelling and evaluate the reliability of the model by comparing it with the experimental data under certain load conditions. The ROM of the paediatric spine was measured using a validated FE model at ±0.5 Nm moment in order to determine the moment required by the synthetic spine to achieve the same ROM. The results showed that the synthetic spine required two moments, ±2 Nm for lateral-bending and axial rotation, and ±3 Nm for flexion-extension, to obtain the paediatric ROM. The synthetic spine was shown to be stiffer in flexion-extension but more flexible in lateral bending than the paediatric FE model, possibly as a result of the intervertebral disc's simplified shape and the disc's weak bonding with the vertebrae. Nevertheless, the synthetic paediatric spine has promising potential in the future as an alternative paediatric spine model for biomechanical investigation of paediatric cases.
Collapse
Affiliation(s)
- Nor Amalina Muhayudin
- Faculty of Mechanical Engineering Technology, Universiti Malaysia Perlis, Pauh Putra Campus, Arau 02600, Malaysia
| | - Khairul Salleh Basaruddin
- Faculty of Mechanical Engineering Technology, Universiti Malaysia Perlis, Pauh Putra Campus, Arau 02600, Malaysia
- Sports Engineering Research Centre (SERC), Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Muhammad Farzik Ijaz
- Mechanical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
- King Salman Center for Disability Research, Riyadh 11614, Saudi Arabia
| | - Ruslizam Daud
- Faculty of Mechanical Engineering Technology, Universiti Malaysia Perlis, Pauh Putra Campus, Arau 02600, Malaysia
- Sports Engineering Research Centre (SERC), Universiti Malaysia Perlis, Arau 02600, Malaysia
| |
Collapse
|
6
|
Vedantam A, Purushothaman Y, Harinathan B, Scripp S, Budde MD, Yoganandan N. Spinal Cord Stress After Anterior Cervical Diskectomy and Fusion: Results from a Patient-Specific Finite Element Model. Ann Biomed Eng 2022; 51:1040-1051. [PMID: 36538274 DOI: 10.1007/s10439-022-03118-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 12/12/2022] [Indexed: 12/24/2022]
Abstract
Degenerative cervical myelopathy (DCM) is the commonest cause of cervical spinal cord dysfunction in older adults and is characterized by spinal cord compression and stress during neck motion. Although surgical decompression eliminates static spinal cord compression, cord stress resulting from flexion-extension motion of the spinal column has not been determined for single and multi-level surgical interventions. The effect of surgery on spinal cord stress is expected to change with the number of surgical levels as well as patient-specific anatomy. Using a MRI-derived patient-specific finite element model, we simulated 1-, 2- and 3-level anterior cervical diskectomy and fusion (ACDF) surgery for DCM. A substantial decrease in spinal cord stress at the level of spinal cord decompression was noted in all simulations. This was associated with a considerable increase in spinal cord stress rostral to the surgical level, and the magnitude of stress was higher in multi-level surgery. Increased spinal cord stress at the rostral adjacent segment correlated with increased segmental range of motion (r = 0.69, p = 0.002) and disk pressure (r = 0.57, p = 0.05). Together, these results indicate that ACDF for DCM is associated with adverse spinal cord stress patterns adjacent to the fusion construct, and further research is needed to determine if the altered stress is associated with clinical outcomes after surgery for DCM.
Collapse
|