1
|
Kuczak J, Wojcieszek J, Królikowski M, Królikowska M, Dominiczak J, Krzemiński J, Budny F, Wojciechowska I, Kopytowski A, Pepłowski A, Górski Ł. A novel type of planar reference electrodes based on ionic liquids. Anal Chim Acta 2025; 1344:343713. [PMID: 39984211 DOI: 10.1016/j.aca.2025.343713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 12/20/2024] [Accepted: 01/22/2025] [Indexed: 02/23/2025]
Abstract
Although electrochemical sensors gained a lot of popularity through recent years, there is very little research on sensors with IL-based reference electrodes. This type of reference electrodes might be the ultimate solution for problem of RE miniaturization. In this paper a novel type of printed reference electrodes based on ionic liquids are presented. The potential stability of electrodes with membranes containing two new ILs with promising properties, namely 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate (EMIM+FAP-) and 1-(2-methoxyethyl)-1-methylpyrrolidin-1-ium tris(pentafluoroethyl)trifluorophosphate (PYR(2o1,1)+FAP-), was investigated. Reference membranes were implemented in classic electrodes with internal electrolyte, as well as deposited on planar transducers with electrodes fabricated using screen printing or aerosol jet printing. Membranes were deposited via drop-casting or by using aerosol jet printer, to form fully printed reference electrodes. It was found that while both tested ionic liquids performed similarly, the use of (PYR(2o1,1)+FAP-) resulted in better potential stability. Planar IL-based electrode was finally used as a reference electrode in a simple pH sensor, enabling the detection of pH changes.
Collapse
Affiliation(s)
- Julia Kuczak
- Warsaw University of Technology, Faculty of Chemistry, Chair of Medical Biotechnology, Noakowskiego 3, 00-664, Warsaw, Poland.
| | - Justyna Wojcieszek
- Warsaw University of Technology, Faculty of Chemistry, Chair of Medical Biotechnology, Noakowskiego 3, 00-664, Warsaw, Poland
| | - Marek Królikowski
- Warsaw University of Technology, Faculty of Chemistry, Department of Physical Chemistry, Noakowskiego 3, 00-664, Warsaw, Poland
| | - Marta Królikowska
- Warsaw University of Technology, Faculty of Chemistry, Department of Physical Chemistry, Noakowskiego 3, 00-664, Warsaw, Poland
| | - Jan Dominiczak
- Warsaw University of Technology, Centre for Advanced Materials and Technologies CEZAMAT, Department of Printed Electronics, e-Textiles and Assembly, Poleczki 19, 02-822, Warsaw, Poland; Warsaw University of Technology, Faculty of Mechanical and Industrial Engineering, Institute of Mechanics and Printing, Narbutta 85, 02-524, Warsaw, Poland
| | - Jakub Krzemiński
- Warsaw University of Technology, Centre for Advanced Materials and Technologies CEZAMAT, Department of Printed Electronics, e-Textiles and Assembly, Poleczki 19, 02-822, Warsaw, Poland
| | - Filip Budny
- Warsaw University of Technology, Centre for Advanced Materials and Technologies CEZAMAT, Department of Printed Electronics, e-Textiles and Assembly, Poleczki 19, 02-822, Warsaw, Poland; Warsaw University of Technology, Faculty of Mechanical and Industrial Engineering, Institute of Mechanics and Printing, Narbutta 85, 02-524, Warsaw, Poland
| | - Izabela Wojciechowska
- Warsaw University of Technology, Centre for Advanced Materials and Technologies CEZAMAT, Department of Printed Electronics, e-Textiles and Assembly, Poleczki 19, 02-822, Warsaw, Poland; Warsaw University of Technology, Faculty of Mechanical and Industrial Engineering, Institute of Mechanics and Printing, Narbutta 85, 02-524, Warsaw, Poland
| | - Adrian Kopytowski
- Warsaw University of Technology, Faculty of Mechanical and Industrial Engineering, Institute of Manufacturing Technologies, Narbutta 85, 02-524, Warsaw, Poland
| | - Andrzej Pepłowski
- Warsaw University of Technology, Centre for Advanced Materials and Technologies CEZAMAT, Department of Printed Electronics, e-Textiles and Assembly, Poleczki 19, 02-822, Warsaw, Poland
| | - Łukasz Górski
- Warsaw University of Technology, Faculty of Chemistry, Chair of Medical Biotechnology, Noakowskiego 3, 00-664, Warsaw, Poland
| |
Collapse
|
2
|
Cai X, Huang Y, Zhu C. Immobilized Multi-Enzyme/Nanozyme Biomimetic Cascade Catalysis for Biosensing Applications. Adv Healthc Mater 2025; 14:e2401834. [PMID: 38889805 DOI: 10.1002/adhm.202401834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 06/17/2024] [Indexed: 06/20/2024]
Abstract
Multiple enzyme-induced cascade catalysis has an indispensable role in the process of complex life activities, and is widely used to construct robust biosensors for analyzing various targets. The immobilized multi-enzyme cascade catalysis system is a novel biomimetic catalysis strategy that immobilizes various enzymes with different functions in stable carriers to simulate the synergistic catalysis of multiple enzymes in biological systems, which enables high stability of enzymes and efficiency enzymatic cascade catalysis. Nanozymes, a type of nanomaterial with intrinsic enzyme-like characteristics and excellent stabilities, are also widely applied instead of enzymes to construct immobilized cascade systems, achieving better catalytic performance and reaction stability. Due to good stability, reusability, and remarkably high efficiency, the immobilized multi-enzyme/nanozyme biomimetic cascade catalysis systems show distinct advantages in promoting signal transduction and amplification, thereby attracting vast research interest in biosensing applications. This review focuses on the research progress of the immobilized multi-enzyme/nanozyme biomimetic cascade catalysis systems in recent years. The construction approaches, factors affecting the efficiency, and applications for sensitive biosensing are discussed in detail. Further, their challenges and outlooks for future study are also provided.
Collapse
Affiliation(s)
- Xiaoli Cai
- Academy of Nutrition and Health, Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, P.R. China
| | - Yuteng Huang
- Academy of Nutrition and Health, Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, P.R. China
| | - Chengzhou Zhu
- State Key Laboratory of Green Pesticide, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan, 430079, P.R. China
| |
Collapse
|
3
|
Qu M, Dong Y, Liu Q, Wang Y, Feng P, Zhang Y, Deng Y, Zhang R, Sun CL, He J. Piezoresistive Sensor Based on Porous Sponge with Superhydrophobic and Flame Retardant Properties for Motion Monitoring and Fire Alarm. ACS APPLIED MATERIALS & INTERFACES 2025; 17:2105-2116. [PMID: 39731544 DOI: 10.1021/acsami.4c12571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2024]
Abstract
Polyurethane sponge is frequently selected as a substrate material for constructing flexible compressible sensors due to its excellent resilience and compressibility. However, being highly hydrophilic and flammable, it not only narrows the range of use of the sensor but also poses a great potential threat to human safety. In this paper, a conductive flexible piezoresistive sensor (CHAP-PU) with superhydrophobicity and high flame retardancy was prepared by a simple dip-coating method using A-CNTs/HGM/ADP coatings deposited on the surface of a sponge skeleton and modified with polydimethylsiloxane. With great sensitivity and durability (>3000 cycles) as well as fast response/recovery time (152 ms/178 ms), the sensor is capable of monitoring human movement as a wearable device. The modified material surface has a hydrophobicity angle of 153°, which provides significant self-cleaning and weather resistance. Furthermore, the CHAP-PU sensor is able to respond stably to underwater movements. Importantly, when the sponge was directly exposed to an open flame, no flame spreading or dripping of molten material was detected, indicating excellent flame retardancy. Meanwhile, CHAP-PU was also equipped as a smart fire alarm system, and the results showed that an alarm signal was triggered within 2 s under flame erosion. Therefore, the flame-retardant superhydrophobic CHAP-PU sponge-based sensor shows great potential for human motion detection and fire alarm applications.
Collapse
Affiliation(s)
- Mengnan Qu
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Yurou Dong
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Qinghua Liu
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
- College of Energy, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Yuqing Wang
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Pu Feng
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Ying Zhang
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Yuan Deng
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Ruizhe Zhang
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Cai-Li Sun
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| | - Jinmei He
- College of Chemistry and Chemical Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| |
Collapse
|
4
|
Aroche AF, Nissan HE, Daniele MA. Hydrogel-Forming Microneedles and Applications in Interstitial Fluid Diagnostic Devices. Adv Healthc Mater 2025; 14:e2401782. [PMID: 39558769 PMCID: PMC11694095 DOI: 10.1002/adhm.202401782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 09/02/2024] [Indexed: 11/20/2024]
Abstract
Hydrogel-forming microneedles are constructed from or coated with polymeric, hydrophilic materials that swell upon insertion into the skin. Designed to dissolve or disintegrate postinsertion, these microneedles can deliver drugs, vaccines, or other therapeutics. Recent advancements have broadened their application scope to include the collection, transport, and extraction of dermal interstitial fluid (ISF) for medical diagnostics. This review presents a brief introduction to the characteristics of dermal ISF, methods for extraction and sampling, and critical assessment of the state-of-the-art in hydrogel-forming microneedles for ISF diagnostics. Key factors are evaluated including material composition, swelling behavior, biocompatibility, and mechanical strength necessary for effective microneedle performance and ISF collection. The review also discusses successful examples of dermal ISF assays and microneedle sensor integrations, highlighting notable achievements, identifying research opportunities, and addressing challenges with potential solutions. Despite the predominance of synthetic hydrogels in reported hydrogel-forming microneedle technologies due to their favorable swelling and gelation properties, there is a significant variety of biopolymers and composites reported in the literature. The field lacks consensus on the optimal material, composition, or fabrication methods, though emerging evidence suggests that processing and fabrication techniques are critical to the performance and utility of hydrogel-forming microneedles for ISF diagnostics.
Collapse
Affiliation(s)
- Angélica F. Aroche
- Joint Department of Biomedical EngineeringNorth Carolina State University and University of North CarolinaChapel Hill, 911 Oval Dr.RaleighNC27695USA
| | - Hannah E. Nissan
- Department of Electrical & Computer EngineeringNorth Carolina State University890 Oval Dr.RaleighNC27695USA
| | - Michael A. Daniele
- Joint Department of Biomedical EngineeringNorth Carolina State University and University of North CarolinaChapel Hill, 911 Oval Dr.RaleighNC27695USA
- Department of Electrical & Computer EngineeringNorth Carolina State University890 Oval Dr.RaleighNC27695USA
| |
Collapse
|
5
|
Messina L, Giardi MT. Recent Status on Lactate Monitoring in Sweat Using Biosensors: Can This Approach Be an Alternative to Blood Detection? BIOSENSORS 2024; 15:3. [PMID: 39852054 PMCID: PMC11763306 DOI: 10.3390/bios15010003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Revised: 12/11/2024] [Accepted: 12/20/2024] [Indexed: 01/26/2025]
Abstract
Recent studies have shown that lactate is a molecule that plays an indispensable role in various physiological cellular processes, such as energy metabolism and signal transductions related to immune and inflammatory processes. For these reasons, interest in its detection using biosensors for non-invasive analyses of sweat during sports activity and in clinical reasons assessments has increased. In this minireview, an in-depth study was carried out on biosensors that exploited using electrochemical methods and innovative nanomaterials for lactate detection in sweat. This detection of lactate by biosensors in the sweat method seems to be feasible and highly desirable. From this commentary analysis, we can conclude that the correlation between lactate concentrations in sweat and blood is not yet clear, and studies are needed to clarify some key issues essential for the future application of this technology.
Collapse
Affiliation(s)
| | - Maria Teresa Giardi
- Microsis srl, Via degli Olmetti, 8a, 00060 Formello, Italy;
- Institute of Cristallography, CNR Area of Research of Rome, 00010 Rome, Italy
| |
Collapse
|
6
|
Weng X, Li M, Chen L, Peng B, Jiang H. A wearable nanozyme-enzyme electrochemical biosensor for sweat lactate monitoring. Talanta 2024; 279:126675. [PMID: 39116726 DOI: 10.1016/j.talanta.2024.126675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 07/12/2024] [Accepted: 08/05/2024] [Indexed: 08/10/2024]
Abstract
In this study, we developed a wearable nanozyme-enzyme electrochemical biosensor that enablies sweat lactate monitoring. The biosensor comprises a flexible electrode system prepared on a polyimide (PI) film and the Janus textile for unidirectional sweat transport. We obtained favorable electrochemical activities for hydrogen peroxide reduction by modifying the laser-scribed graphene (LSG) electrode with cerium dioxide (CeO2)-molybdenum disulphide (MoS2) nanozyme and gold nanoparticles (AuNPs). By further immobilisation of lactate oxidase (LOx), the proposed biosensor achieves chronoamperometric lactate detection in artificial sweat within a range of 0.1-50.0 mM, a high sensitivity of 25.58 μA mM-1cm-2 and a limit of detection (LoD) down to 0.135 mM, which fully meets the requirements of clinical diagnostics. We demonstrated accurate lactate measurements in spiked artificial sweat, which is consistent with standard ELISA results. To monitor the sweat produced by volunteers while exercising, we conducted on-body tests, showcasing the wearable biosensor's ability to provide clinical sweat lactate diagnosis for medical treatment and sports management.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong, 523808, China
| | - Ming Li
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China
| | - Longyan Chen
- Department of Biomedical, Industrial & Systems Engineering, Gannon University, 109 University Square, Erie, PA, 16541, USA
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong, 523808, China.
| |
Collapse
|
7
|
Zhou Q, Wang X, Tang K, Chen Y, Wang R, Lei H, Yang Z, Zhang Z. Developing portable and controllable fluorescence capillary imprinted sensor for visual detection Crohn's disease biomarkers. Talanta 2024; 278:126402. [PMID: 38924985 DOI: 10.1016/j.talanta.2024.126402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 05/25/2024] [Accepted: 06/09/2024] [Indexed: 06/28/2024]
Abstract
Simultaneous detection of multiple biomarker levels is essential to improve the accuracy of early diagnosis. Introducing capillary will simplify procedure, less time, and reduce reagent consumption for point-of-care testing of biomarkers. Here, we developed a portable and controllable smartphone-integrated fluorescence capillary imprinted sensing platform for the accuracy visual detection of Crohn's disease biomarkers (lysozyme, Fe3+) using single-excitation/double-signal detection. A novel controllable capillary coating strategy was developed by static gas-driven coating method for synthesis uniform fluorescence capillary imprinted sensor (Si-CD/g-CdTe@MIP capillary sensor). When Fe3+ and lysozyme were added, the fluorescence intensity of Si-CD/g-CdTe@MIP capillary sensor was quenched at 426 nm and enhanced at 546 nm, respectively. This Si-CD/g-CdTe@MIP capillary sensor has high sensitivity and selectivity for quantification lysozyme and Fe3+ simultaneously with the detection limit of 0.098 nM and 0.20 nM, respectively. In addition, the smartphone-integrated Si-CD/g-CdTe@MIP capillary sensor was applied for the intelligent detection of lysozyme and Fe3+, in which the detection limit was calculated as 0.32 nM and 0.65 nM. The smartphone-integrated visual Si-CD/g-CdTe@MIP capillary sensor realized ultrasensitive microanalysis (18 μL/time) of biomarkers in health man and Crohn 's patients, providing a novel strategy for early diagnosis of Crohn 's disease.
Collapse
Affiliation(s)
- Qin Zhou
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China; Ley Laboratory of Medicinal Resources Chemistry and Pharmacology in Wuling Mountainous of Hunan Province College, Jishou University, Jishou, 416000, PR China
| | - Xiangni Wang
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China; Ley Laboratory of Medicinal Resources Chemistry and Pharmacology in Wuling Mountainous of Hunan Province College, Jishou University, Jishou, 416000, PR China
| | - Kangling Tang
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China
| | - Yu Chen
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China
| | - Ruoyan Wang
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China; Ley Laboratory of Medicinal Resources Chemistry and Pharmacology in Wuling Mountainous of Hunan Province College, Jishou University, Jishou, 416000, PR China
| | - Huibin Lei
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China
| | - Zhaoxia Yang
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China
| | - Zhaohui Zhang
- College of Chemistry and Chemical Engineering, Jishou University, Jishou, 416000, PR China; Ley Laboratory of Medicinal Resources Chemistry and Pharmacology in Wuling Mountainous of Hunan Province College, Jishou University, Jishou, 416000, PR China.
| |
Collapse
|
8
|
Tsvik L, Zhang S, O'Hare D, Haltrich D, Sützl L. More Than One Enzyme: Exploring Alternative FMN-Dependent L-Lactate Oxidases for Biosensor Development. ACS OMEGA 2024; 9:29442-29452. [PMID: 39005781 PMCID: PMC11238220 DOI: 10.1021/acsomega.4c01897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 06/05/2024] [Accepted: 06/14/2024] [Indexed: 07/16/2024]
Abstract
The α-hydroxy acid oxidoreductase (HAOx) family contains a diverse group of enzymes that can be applied in biosensors for L-lactate detection, most prominently lactate oxidase (LOx). The limited availability and a lack of diversity of L-lactate-oxidizing enzymes have currently hindered advancements in L-lactate biosensor development. Until now, the field has mostly relied on a single, commercially available enzyme, namely Aerococcus viridans L-lactate oxidase (AvLOx). In this study, we present newly discovered alternative L-lactate oxidases that exhibit a narrow substrate specificity and varied kinetic efficiencies toward L-lactate, making them suitable for integration into existing biosensor configurations. Some of these FMN-dependent L-lactate oxidases could be obtained in substantial amounts from routine E. coli expression, potentially facilitating commercial production. Using electrochemical characterization with a mediated biosensor setup, we present 7 enzymes that perform comparable or even better than commercial AvLOx. Finally, we show that their electrochemical performance is not directly correlating with their biochemical performance, making predictions of the suitability of enzymes for biosensor applications extremely difficult. Our research emphasizes the significance of expanding the enzyme toolbox of L-lactate oxidases for the development of improved L-lactate biosensors.
Collapse
Affiliation(s)
- Lidiia Tsvik
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
- Doctoral Programme 'Biomolecular Technology of Proteins (BioToP)', University of Natural Resources and Life Sciences, Muthgasse 18, Wien, Vienna A-1190, Austria
| | - Shulin Zhang
- Department of Bioengineering, Imperial College London, London SW72AZ, U.K
| | - Danny O'Hare
- Department of Bioengineering, Imperial College London, London SW72AZ, U.K
| | - Dietmar Haltrich
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
| | - Leander Sützl
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
| |
Collapse
|
9
|
Pareek N, Mendiratta S, Kalita N, Sivaramakrishnan S, Khan RS, Samanta A. Unraveling Ferroptosis Mechanisms: Tracking Cellular Viscosity with Small Molecular Fluorescent Probes. Chem Asian J 2024; 19:e202400056. [PMID: 38430218 DOI: 10.1002/asia.202400056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/28/2024] [Accepted: 03/01/2024] [Indexed: 03/03/2024]
Abstract
Ferroptosis is a recently identified form of regulated cell death characterized by iron accumulation and lipid peroxidation. Numerous functions for ferroptosis have been identified in physiological as well as pathological processes, most notably in the treatment of cancer. The intricate balance of redox homeostasis is profoundly altered during ferroptosis, leading to alteration in cellular microenvironment. One such microenvironment is viscosity among others such as pH, polarity, and temperature. Therefore, understanding the dynamics of ferroptosis associated viscosity levels within organelles is crucial. To date, there are a very few reviews that detects ferroptosis assessing reactive species. In this review, we have summarized organelle's specific fluorescent probes that detects dynamics of microviscosity during ferroptosis. Also, we offer the readers an insight of their design strategy, photophysics and associated bioimaging concluding with the future perspective and challenges in the related field.
Collapse
Affiliation(s)
- Niharika Pareek
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| | - Sana Mendiratta
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| | - Nripankar Kalita
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| | - Shreya Sivaramakrishnan
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| | - Rafique Sanu Khan
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| | - Animesh Samanta
- Department of Chemistry, School of Natural Sciences Institution, Shiv Nadar Institution of Eminence (SNIoE), Delhi NCR, Greater Noida, Uttar Pradesh, 201314, India
| |
Collapse
|
10
|
Zhang J, Fang Z, Dong H, Liu Y, Chu Z, Mou Y, Jin W. MnFe@N-CNTs Based Lactate Biomicrochips for Nonintrusive and Onsite Periodontitis Diagnosis. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 38593051 DOI: 10.1021/acsami.4c00979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
In clinical settings, saliva has been established as a straightforward, noninvasive medium for diagnosing periodontitis. However, the precise diagnosis is often hampered by the absence of a specialized analyzer capable of detecting low concentrations of biomarkers typically found in saliva. In this study, we present a noninvasive, on-site screen-printed biomicrochip specifically engineered for the precise and sensitive quantification of lactate concentrations in saliva, a critical biomarker in the diagnosis of periodontitis. The microchip is constructed using a nanostructured ink formulation that includes MnFe@N-doped carbon nanotubes (MnFe@N-CNTs). These MnFe@N-CNTs exhibit a high degree of graphitization and low electrical resistance, significantly augmenting the electrocatalytic efficiency of the enzymatic reaction of lactate. This results in doubled sensitivity and a detection limit that surpasses those of the current advanced salivary assay methods. Remarkably, within just 30 s, the biomicrochip can quantitatively and precisely measure lactate concentrations in the saliva of 10 patients, which provides valuable insights into the severity of their periodontitis. This biosensor holds excellent potential for large-scale production and could broaden the scope of biomarker recognition, paving the way for the analysis of a wider range of oral diseases.
Collapse
Affiliation(s)
- Jing Zhang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
| | - Zishuo Fang
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
| | - Heng Dong
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, No. 30 Zhongyang Road, Nanjing 210008, P. R. China
| | - Yu Liu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
| | - Zhenyu Chu
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
| | - Yongbin Mou
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, No. 30 Zhongyang Road, Nanjing 210008, P. R. China
| | - Wanqin Jin
- State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, No. 30 Puzhu Road(S), Nanjing 211816, P. R. China
| |
Collapse
|
11
|
Lafuente JL, González S, Aibar C, Rivera D, Avilés E, Beunza JJ. Continuous and Non-Invasive Lactate Monitoring Techniques in Critical Care Patients. BIOSENSORS 2024; 14:148. [PMID: 38534255 PMCID: PMC10968200 DOI: 10.3390/bios14030148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 03/05/2024] [Accepted: 03/09/2024] [Indexed: 03/28/2024]
Abstract
Lactate, once merely regarded as an indicator of tissue hypoxia and muscular fatigue, has now gained prominence as a pivotal biomarker across various medical disciplines. Recent research has unveiled its critical role as a high-value prognostic marker in critical care medicine. The current practice of lactate detection involves periodic blood sampling. This approach is invasive and confined to measurements at six-hour intervals, leading to resource expenditure, time consumption, and patient discomfort. This review addresses non-invasive sensors that enable continuous monitoring of lactate in critical care patients. After the introduction, it discusses the iontophoresis system, followed by a description of the structural materials that are universally employed to create an interface between the integumentary system and the sensor. Subsequently, each method is detailed according to its physical principle, outlining its advantages, limitations, and pertinent aspects. The study concludes with a discussion and conclusions, aiming at the design of an intelligent sensor (Internet of Medical Things or IoMT) to facilitate continuous lactate monitoring and enhance the clinical decision-making support system in critical care medicine.
Collapse
Affiliation(s)
- Jose-Luis Lafuente
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Samuel González
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Intensive Care Unit, Hospital Universitario HLA Moncloa, 28008 Madrid, Spain
| | - Clara Aibar
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Desirée Rivera
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Eva Avilés
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Engineering Department, School of Architecture, Engineering & Design, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| | - Juan-Jose Beunza
- IASalud, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain; (J.-L.L.); (S.G.); (C.A.); (D.R.); (E.A.)
- Research and Doctorate School, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
- Department of Medicine, Health and Sports, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
| |
Collapse
|
12
|
Rocha KN, da Silva JAF, de Jesus DP. Capillary electrophoresis with capacitively coupled contactless conductivity detection (C 4 D) for rapid and simple determination of lactate in sweat. Electrophoresis 2024; 45:392-399. [PMID: 38072648 DOI: 10.1002/elps.202300179] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 03/20/2024]
Abstract
An analytical method based on capillary electrophoresis (CE) using capacitively coupled contactless conductivity detection (C4 D) was developed and validated for fast, straightforward, and reliable determination of lactate in artificial and human sweat samples. The background electrolyte was composed of equimolar concentrations (10 mmol/L) of 2-(N-morpholino)ethanesulfonic acid and histidine, with 0.2 mmol/L of cetyltrimethylammonium bromide as electroosmotic flow inverter. The limit of detection and quantification were 3.1 and 10.3 µmol/L, respectively. Recoveries in the 97 to 118% range were obtained using sweat samples spiked with lactate at three concentration levels, indicating an acceptable accuracy. The intraday and interday precisions were 1.49 and 7.08%, respectively. The proposed CE-C4 D method can be a starting point for monitoring lactate concentrations in sweat samples for diagnostics, physiological studies, and sports performance assessment applications.
Collapse
Affiliation(s)
- Kionnys N Rocha
- Instituto de Química, Universidade Estadual de Campinas, UNICAMP, Campinas, São Paulo, Brazil
| | - José A Fracassi da Silva
- Instituto de Química, Universidade Estadual de Campinas, UNICAMP, Campinas, São Paulo, Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, São Paulo, Brazil
| | - Dosil P de Jesus
- Instituto de Química, Universidade Estadual de Campinas, UNICAMP, Campinas, São Paulo, Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, São Paulo, Brazil
| |
Collapse
|