1
|
Cai P, Wang J, Ye P, Zhang Y, Wang M, Guo R, Zhao H. Performance of self-performed SARS-CoV-2 rapid antigen test: a systematic review and meta-analysis. Front Public Health 2024; 12:1402949. [PMID: 39494084 PMCID: PMC11527648 DOI: 10.3389/fpubh.2024.1402949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 10/08/2024] [Indexed: 11/05/2024] Open
Abstract
Background The aim of this study was to investigate the accuracy of self-tested SARS-CoV-2 rapid antigen tests. Methods Databases of Pubmed, Embase, and Cochrane Library were searched for original studies investigating accuracy of self-tested SARS-CoV-2 rapid antigen tests, with RT-PCR as "gold standard." Results Forty-five eligible studies were found after database searching and screening using pre-defined criteria. The accuracy results from 50,897 suspected COVID-19 patients were pooled, and the overall sensitivity, specificity and diagnostic odds ratio were 0.77, 1.00, and 625.95, respectively. Subgroup analysis showed higher sensitivity of rapid antigen tests in subgroups of Abbott Panbio, self-collected nasal swab samples, and use of nasopharyngeal or oropharyngeal swab and lower Ct cutoff value in RT-PCR. Conclusion Fully self-performed SARS-CoV-2 rapid antigen tests showed overall high accuracy compared to "gold standard," and are reliable surrogates for the standard test of COVID-19 using nasopharyngeal or oropharyngeal samples and RT-PCR.
Collapse
Affiliation(s)
- Peiling Cai
- Department of Anatomy and Histology, School of Preclinical Medicine, Chengdu University, Chengdu, Sichuan, China
| | - Junren Wang
- Department of Anatomy and Histology, School of Preclinical Medicine, Chengdu University, Chengdu, Sichuan, China
- Clinical Medical College & Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
| | - Peng Ye
- Department of Anatomy and Histology, School of Preclinical Medicine, Chengdu University, Chengdu, Sichuan, China
| | - Yarong Zhang
- The First Affiliated Hospital of Xi'an Jiaotong University, Xi’an, Shannxi, China
| | - Mengping Wang
- Department of Anatomy and Histology, School of Preclinical Medicine, Chengdu University, Chengdu, Sichuan, China
| | - Ronglian Guo
- Department of Pediatrics, Zhongshan Hospital of Xiamen University, Xiamen University, Xiamen, Fujian, China
| | - Hongying Zhao
- Department of Pediatrics, Zhongshan Hospital of Xiamen University, Xiamen University, Xiamen, Fujian, China
| |
Collapse
|
2
|
Nian Y, Zhang S, Wang J, Li X, Wang Y, Liu J, Liu Z, Ye Y, You C, Yin H, Guan G. A novel and low-cost cross-priming amplification assay for rapid detection of Babesia duncani infection. Exp Parasitol 2024; 265:108813. [PMID: 39117169 DOI: 10.1016/j.exppara.2024.108813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 08/02/2024] [Accepted: 08/05/2024] [Indexed: 08/10/2024]
Abstract
Babesia duncani, responsible for human babesiosis, is one of the most important tick-borne intraerythrocytic pathogens. Traditionally, babesiosis is definitively diagnosed by detecting parasite DNA in blood samples and examining Babesia parasites in Giemsa-stained peripheral blood smears. Although these techniques are valuable for determining Babesia duncani, they are often time-consuming and laborious. Therefore, developing rapid and reliable B. duncani identification assays is essential for subsequent epidemiological investigations and prevention and control. In this study, a cross-priming amplification (CPA) assay was developed, combined with a vertical flow visualization strip, to rapidly and accurately detect B. duncani infection. The detection limit of this method was as low as 0.98 pg/μl of genomic DNA from B. duncani merozoites per reaction at 59 °C for 60 min. There were no cross-reactions between B. duncani and other piroplasms infective to humans and mammals. A total of 592 blood samples from patients bitten by ticks and experimental infected hamsters were accurately assessed using CPA assay. The average cost of the CPA assay is as low as approximately $ 0.2 per person. These findings indicate that the CPA assay may therefore be a rapid screening tool for detection B. duncani infection, based on its accuracy, speed, and cost-effectiveness, particularly in resource-limited regions with a high prevalence of human babesiosis.
Collapse
Affiliation(s)
- Yueli Nian
- Laboratory Medicine Center, Lanzhou University Second Hospital, Cuiyingmen 82, Lanzhou, Gansu, 730030, PR China; State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Shangdi Zhang
- Laboratory Medicine Center, Lanzhou University Second Hospital, Cuiyingmen 82, Lanzhou, Gansu, 730030, PR China
| | - Jinming Wang
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Xiaoyun Li
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Yanbo Wang
- Laboratory Medicine Center, Lanzhou University Second Hospital, Cuiyingmen 82, Lanzhou, Gansu, 730030, PR China
| | - Junlong Liu
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Zeen Liu
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Yuxin Ye
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China
| | - Chongge You
- Laboratory Medicine Center, Lanzhou University Second Hospital, Cuiyingmen 82, Lanzhou, Gansu, 730030, PR China.
| | - Hong Yin
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China; Jiangsu Co-Innovation Center for the Prevention and Control of Important Animal Infectious Disease and Zoonoses, Yangzhou University, Yangzhou, 225009, PR China.
| | - Guiquan Guan
- State Key Laboratory for Animal Disease Control and Prevention, Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Science, Xujiaping 1, Lanzhou, Gansu, 730046, PR China.
| |
Collapse
|
3
|
Hirabayashi E, Mercado G, Hull B, Soin S, Koshy-Chenthittayil S, Raman S, Huang T, Keerthisinghe C, Feliciano S, Dongo A, Kal J, Azizan A, Duus K, Else T, DeArmond M, Stone AE. Comparison of diagnostic accuracy of rapid antigen tests for COVID-19 compared to the viral genetic test in adults: a systematic review and meta-analysis. JBI Evid Synth 2024; 22:1939-2002. [PMID: 39188132 PMCID: PMC11462910 DOI: 10.11124/jbies-23-00291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
OBJECTIVE The objective of this review was to determine the diagnostic accuracy of the currently available and upcoming point-of-care rapid antigen tests (RATs) used in primary care settings relative to the viral genetic real-time reverse transcriptase polymerase chain reaction (RT-PCR) test as a reference for diagnosing COVID-19/SARS-CoV-2 in adults. INTRODUCTION Accurate COVID-19 point-of-care diagnostic tests are required for real-time identification of SARS-CoV-2 infection in individuals. Real-time RT-PCR is the accepted gold standard for diagnostic testing, requiring technical expertise and expensive equipment that are unavailable in most primary care locations. RATs are immunoassays that detect the presence of a specific viral protein, which implies a current infection with SARS-CoV-2. RATs are qualitative or semi-quantitative diagnostics that lack thresholds that provide a result within a short time frame, typically within the hour following sample collection. In this systematic review, we synthesized the current evidence regarding the accuracy of RATs for detecting SARS-CoV-2 compared with RT-PCR. INCLUSION CRITERIA Studies that included nonpregnant adults (18 years or older) with suspected SARS-CoV-2 infection, regardless of symptomology or disease severity, were included. The index test was any available SARS-CoV-2 point-of-care RAT. The reference test was any commercially distributed RT-PCR-based test that detects the RNA genome of SARS-CoV-2 and has been validated by an independent third party. Custom or in-house RT-PCR tests were also considered, with appropriate validation documentation. The diagnosis of interest was COVID-19 disease and SARS-CoV-2 infection. This review considered cross-sectional and cohort studies that examined the diagnostic accuracy of COVID-19/SARS-CoV-2 infection where the participants had both index and reference tests performed. METHODS The keywords and index terms contained in relevant articles were used to develop a full search strategy for PubMed and adapted for Embase, Scopus, Qinsight, and the WHO COVID-19 databases. Studies published from November 2019 to July 12, 2022, were included, as SARS-CoV-2 emerged in late 2019 and is the cause of a continuing pandemic. Studies that met the inclusion criteria were critically appraised using QUADAS-2. Using a customized tool, data were extracted from included studies and were verified prior to analysis. The pooled sensitivity, specificity, positive predictive, and negative predictive values were calculated and presented with 95% CIs. When heterogeneity was observed, outlier analysis was conducted, and the results were generated by removing outliers. RESULTS Meta-analysis was performed on 91 studies of 581 full-text articles retrieved that provided true-positive, true-negative, false-positive, and false-negative values. RATs can identify individuals who have COVID-19 with high reliability (positive predictive value 97.7%; negative predictive value 95.2%) when considering overall performance. However, the lower level of sensitivity (67.1%) suggests that negative test results likely need to be retested through an additional method. CONCLUSIONS Most reported RAT brands had only a few studies comparing their performance with RT-PCR. Overall, a positive RAT result is an excellent predictor of a positive diagnosis of COVID-19. We recommend that Roche's SARS-CoV-2 Rapid Antigen Test and Abbott's BinaxNOW tests be used in primary care settings, with the understanding that negative results need to be confirmed through RT-PCR. We recommend adherence to the STARD guidelines when reporting on diagnostic data. REVIEW REGISTRATION PROSPERO CRD42020224250.
Collapse
Affiliation(s)
- Ellyn Hirabayashi
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Guadalupe Mercado
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Brandi Hull
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Sabrina Soin
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Sherli Koshy-Chenthittayil
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Sarina Raman
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Timothy Huang
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Chathushya Keerthisinghe
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Shelby Feliciano
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Andrew Dongo
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - James Kal
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Azliyati Azizan
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Karen Duus
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Terry Else
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| | - Megan DeArmond
- Touro University Nevada, Jay Sexter Library, Henderson, NV, USA
- Touro University Nevada: JBI Affiliated Group, Henderson, NV, USA
| | - Amy E.L. Stone
- Touro University Nevada, College of Osteopathic Medicine, Department of Basic Sciences, Henderson, NV, USA
| |
Collapse
|
4
|
Vásquez V, Orozco J. Clinical validation of SARS-CoV-2 electrochemical immunosensor based on the spike-ACE2 complex. J Virol Methods 2024; 327:114940. [PMID: 38608761 DOI: 10.1016/j.jviromet.2024.114940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 03/18/2024] [Accepted: 04/05/2024] [Indexed: 04/14/2024]
Abstract
BACKGROUND AND AIMS Advances in health, especially in prevention, diagnosis, and treatment, have significantly impacted the way of facing emerging infectious diseases. Yet, events such as the COVID-19 pandemic have shown that there is still a long way to go. Therefore, an urgent need exists for portable and easily deployable point-of-care (POC) detection tools. Biosensors at the POC remain in the laboratory in an analytical characterization step and are not yet mature enough to reach the market massively. In this context, it is necessary to progress in validating these devices to demonstrate their relevance in detecting different disease biomarkers. This work reports on the clinical validation of an electrochemical immunosensor for detecting SARS-CoV-2. METHODS A monocentric retrospective cohort study was conducted with 150 random nasopharyngeal swabs or tracheal aspiration samples tested by RT-PCR. The immunosensor based on magnetic beads and chronoamperometry detected SARS-CoV-2 through the spike-angiotensin-converting protein (ACE2) immunocomplex. RESULTS This biosensor demonstrated 96.04 % clinical sensitivity and 87.75 % clinical specificity in detecting SARS-CoV-2 in the samples, highly correlated with the RT-PCR gold standard. CONCLUSIONS It demonstrates the potential of electrochemical biosensors to be implemented as highly sensitive and easily deployable detection strategies even in remote locations.
Collapse
Affiliation(s)
- Viviana Vásquez
- Max Planck Tandem Group in Nanobioengineering. Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 Nº 52-20, Medellín 050010, Colombia
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering. Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 Nº 52-20, Medellín 050010, Colombia.
| |
Collapse
|
5
|
Liu Y, Hu B, Li J, Pei X, Hu X. Perspectives and Prospects on the Application of DNA Aptamer in SARS-CoV-2. Curr Med Chem 2024; 31:273-279. [PMID: 37031389 DOI: 10.2174/0929867330666230408193030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 02/06/2023] [Accepted: 02/22/2023] [Indexed: 04/10/2023]
Affiliation(s)
- Yunyi Liu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Biology, Molecular Science and Biomedicine Laboratory and Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan, 410082, China
| | - Bei Hu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Biology, Molecular Science and Biomedicine Laboratory and Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan, 410082, China
| | - Juan Li
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Biology, Molecular Science and Biomedicine Laboratory and Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan, 410082, China
| | - Xiaming Pei
- Department of Urology, Hunan Cancer Hospital and The Affiliated Cancer Hospital of Xiangya School of Medicine. Changsha, Hunan, 410013, China
| | - Xiaoxiao Hu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Biology, Molecular Science and Biomedicine Laboratory and Aptamer Engineering Center of Hunan Province, Hunan University, Changsha, Hunan, 410082, China
- Research Institute of Hunan University in Chongqing, Chongqing, 401120, China
- Shenzhen Research Institute, Hunan University, Shenzhen, 518000, China
| |
Collapse
|
6
|
Li JP, Kuo YC, Liao WN, Yang YT, Chen SY, Chien YT, Wu KH, Wang MY, Chou FI, Yang MH, Hueng DY, Yang CS, Chen JK. Harnessing Nuclear Energy to Gold Nanoparticles for the Concurrent Chemoradiotherapy of Glioblastoma. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2821. [PMID: 37947667 PMCID: PMC10650840 DOI: 10.3390/nano13212821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/26/2023] [Accepted: 09/27/2023] [Indexed: 11/12/2023]
Abstract
Nuclear fission reactions can release massive amounts of energy accompanied by neutrons and γ photons, which create a mixed radiation field and enable a series of reactions in nuclear reactors. This study demonstrates a one-pot/one-step approach to synthesizing radioactive gold nanoparticles (RGNP) without using radioactive precursors and reducing agents. Trivalent gold ions are reduced into gold nanoparticles (8.6-146 nm), and a particular portion of 197Au atoms is simultaneously converted to 198Au atoms, rendering the nanoparticles radioactive. We suggest that harnessing nuclear energy to gold nanoparticles is feasible in the interests of advancing nanotechnology for cancer therapy. A combination of RGNP applied through convection-enhanced delivery (CED) and temozolomide (TMZ) through oral administration demonstrates the synergistic effect in treating glioblastoma-bearing mice. The mean survival for RGNP/TMZ treatment was 68.9 ± 9.7 days compared to that for standalone RGNP (38.4 ± 2.2 days) or TMZ (42.8 ± 2.5 days) therapies. Based on the verification of bioluminescence images, positron emission tomography, and immunohistochemistry inspection, the combination treatment can inhibit the proliferation of glioblastoma, highlighting the niche of concurrent chemoradiotherapy (CCRT) attributed to RGNP and TMZ.
Collapse
Affiliation(s)
- Jui-Ping Li
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Yu-Cheng Kuo
- Department of Radiation Oncology, China Medical University Hospital, Taichung 40447, Taiwan;
- School of Medicine, China Medical University, Taichung 40402, Taiwan
| | - Wei-Neng Liao
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Ya-Ting Yang
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Sih-Yu Chen
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Yu-Ting Chien
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Kuo-Hung Wu
- Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu 30013, Taiwan; (K.-H.W.); (M.-Y.W.); (F.-I.C.)
| | - Mei-Ya Wang
- Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu 30013, Taiwan; (K.-H.W.); (M.-Y.W.); (F.-I.C.)
| | - Fong-In Chou
- Nuclear Science and Technology Development Center, National Tsing Hua University, Hsinchu 30013, Taiwan; (K.-H.W.); (M.-Y.W.); (F.-I.C.)
| | - Mo-Hsiung Yang
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan;
| | - Dueng-Yuan Hueng
- School of Medicine, National Defense Medical Center, Taipei 11490, Taiwan;
| | - Chung-Shi Yang
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
| | - Jen-Kun Chen
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan; (J.-P.L.); (W.-N.L.); (Y.-T.Y.); (S.-Y.C.); (Y.-T.C.); (C.-S.Y.)
- Biotechnology Center, National Chung Hsing University, Taichung 40227, Taiwan
- Graduate Institute of Life Sciences, National Defense Medical Center, Taipei 11490, Taiwan
| |
Collapse
|
7
|
Yang N, Liu K, Zhang W, Li Y, Shen S, Lu C, Xu K, Peng W, Deng C, Chen M, Yang L, Lai S. Predicting late-onset preeclampsia by detecting ELABELA content using an immunochromatographic colloidal gold test strip: Blood ELABELA content predicts the risk of pre-eclampsia. J Clin Hypertens (Greenwich) 2023; 25:932-942. [PMID: 37746730 PMCID: PMC10560972 DOI: 10.1111/jch.14724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 08/18/2023] [Accepted: 08/18/2023] [Indexed: 09/26/2023]
Abstract
Preeclampsia is a pregnancy disorder that seriously affects the outcome of mothers and infants and lacks effective prediction and diagnosis methods. ELABELA is the second endogenous ligand of the apelin receptor (APJ) and is associated with the pathogenesis of preeclampsia. In a previous study, the authors found that the downregulation of ELABELA expression is closely related to late-onset preeclampsia, which may be a marker for the clinical diagnosis of late-onset preeclampsia. In this study, the authors again collected 120 maternal blood samples, including 60 pregnant women with a medical diagnosis of late-onset preeclampsia. ELISA results showed that the serum ELABELA concentration in late-onset preeclampsia pregnant women (12.57 ± 7.77 ng/mL) was significantly lower than that in normal pregnant women (36.99 ± 23.58 ng/mL), which was consistent with previously reported results. Therefore, the authors used an ELABELA monoclonal antibody to label four colloidal gold nanoparticles with different diameters (15, 30, 55, and 150 nm) and developed a transverse-flow immunochromatographic band for the rapid and accurate detection of serum ELABELA levels. The strip test shows that colloidal gold with a diameter of 30 nm can be used as a good ELABELA detection marker and had more than 90% positive detection effect. Therefore, the authors hope that the colloidal gold strip with ELABELA as the diagnostic index developed by us will be popularized and applied in clinical diagnosis.
Collapse
Affiliation(s)
- Na Yang
- School of Life SciencesNanjing Normal UniversityNanjingChina
| | - Kangsheng Liu
- Department of Clinical LaboratoryWomen's Hospital of Nanjing Medical UniversityNanjing Maternity and Child Health Care HospitalNanjingChina
| | - Wenli Zhang
- School of Life SciencesNanjing Normal UniversityNanjingChina
| | - Ying Li
- Pan'an Mason Medical Technology Co., LTD.JinhuaChina
| | - Suqin Shen
- Department of Clinical LaboratoryWomen's Hospital of Nanjing Medical UniversityNanjing Maternity and Child Health Care HospitalNanjingChina
| | - Chuanchuan Lu
- Department of Obstetrics and GynecologyWomen's Hospital of Nanjing Medical UniversityNanjing Maternity and Child Health Care HospitalNanjingChina
| | - Kai Xu
- School of Life SciencesNanjing Normal UniversityNanjingChina
| | - Wei Peng
- Guangzhou Key Laboratory for Clinical Rapid Diagnosis and Early Warning of Infectious DiseasesKingMed School of Laboratory MedicineGuangzhou Medical UniversityGuangzhouChina
| | - Cheng Deng
- School of Life SciencesNanjing Normal UniversityNanjingChina
| | - Meilin Chen
- Pan'an County maternal and Child Health Hospital, Clinical LaboratoryJinhuaChina
| | - Lindong Yang
- Department of Obstetrics & GynecologyAffiliated Jinling HospitalMedical School of Nanjing UniversityNanjingChina
| | - Shanshan Lai
- School of Life SciencesNanjing Normal UniversityNanjingChina
| |
Collapse
|
8
|
Pan W, Han Z, Chang Y, Yan X, Zhou F, Shen S, Duan X. Rational design of multivalent biosensor surfaces to enhance viral particle capture. J Mater Chem B 2023; 11:4511-4522. [PMID: 37161578 DOI: 10.1039/d2tb02828j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Viral particles bind to receptors through multivalent protein interactions. Such high avidity interactions on sensor surfaces are less studied. In this work, three polyelectrolytes that can form biosensing surfaces with different interfacial characteristics in probe density and spatial arrangement were designed. Quartz crystal microbalance, interferometry and atomic force microscopy were used to study their surface density and binding behaviors with proteins and virus particles. A multivalent adsorption kinetic model was developed to estimate the number of bonds from the viral particles bound to the polyelectrolyte surfaces. Experimental results show that the heterogeneous 3D surface with jagged forest-like structure enhances the virus capture ability by maximizing the multivalent interactions. As a proof of concept, specific coronavirus detection was achieved in spiked swab samples. These results indicate the importance of both probe density and their spatial arrangement on the sensing performance, which could be used as a guideline for rational biosensing surface design.
Collapse
Affiliation(s)
- Wenwei Pan
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- Department of Chemistry, School of Science, Tianjin University, Tianjin 300072, China
| | - Ziyu Han
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Ye Chang
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xu Yan
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Feng Zhou
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Sihong Shen
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
- Department of Chemistry, School of Science, Tianjin University, Tianjin 300072, China
| |
Collapse
|
9
|
Wang P, Xu X, Guo L, Liu L, Kuang H, Xiao J, Xu C. Hapten synthesis and a colloidal gold immunochromatographic strip assay to detect nitrofen and bifenox in fruits. Analyst 2023; 148:2449-2458. [PMID: 37144547 DOI: 10.1039/d3an00358b] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
In this study, we synthesized two haptens similar in structure to nitrofen (NIT), and screened out five monoclonal antibodies with the ability to recognize NIT and bifenox (BIF) by competitive ELISA, with the lowest IC50 values of 0.87 ng mL-1 and 0.86 ng mL-1, respectively. The antibody 5G7 was selected to be combined with colloidal gold to establish a lateral flow immunochromatographic assay strip. This method was shown to qualitatively and quantitatively detect the residues of NIT and BIF in fruit samples. The visual limits of detection for qualitative detection were 5 μg kg-1 and 10 μg kg-1 for NIT and BIF, respectively. The calculated limits of detection for quantitative detection were 0.75 μg kg-1, 1.77 μg kg-1 and 2.55 μg kg-1 respectively, for nitrofen in orange, apple and grapes, and 3.54 μg kg-1, 4.96 μg kg-1 and 5.26 μg kg-1, respectively, for bifenox. Thus the strip assay could be used for rapid analysis of fruit samples.
Collapse
Affiliation(s)
- Peng Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| | - Lingling Guo
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| | - Liqiang Liu
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| | - Jing Xiao
- NHC Key Laboratory of Food Safety Risk Assessment, China National Center for Food Safety Risk Assessment, Beijing, People's Republic of China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology, Jiangnan University, China.
- Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, 214122, People's Republic of China
| |
Collapse
|
10
|
Fragkou PC, De Angelis G, Menchinelli G, Can F, Garcia F, Morfin-Sherpa F, Dimopoulou D, Dimopoulou K, Zelli S, de Salazar A, Reiter R, Janocha H, Grossi A, Omony J, Skevaki C. Update of ESCMID COVID-19 guidelines: diagnostic testing for SARS-CoV-2. Clin Microbiol Infect 2023:S1198-743X(23)00192-1. [PMID: 37088423 PMCID: PMC10122552 DOI: 10.1016/j.cmi.2023.04.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 04/13/2023] [Accepted: 04/16/2023] [Indexed: 04/25/2023]
Abstract
SCOPE Since the onset of coronavirus disease 2019 (COVID-19), several assays have been deployed for the diagnosis of SARS-CoV-2. The European Society of Clinical Microbiology and Infectious Diseases (ESCMID) published the first set of guidelines on SARS-CoV-2 in-vitro diagnosis in February 2022. Since the COVID-19 landscape is rapidly evolving, the relevant ESCMID guidelines panel releases an update of the previously published recommendations on diagnostic testing for SARS-CoV-2. This update aims to delineate the best diagnostic approach for SARS-CoV-2 in different populations based on current evidence. METHODS An ESCMID COVID-19 guidelines task force was established by the ESCMID Executive Committee. A small group was established, half appointed by the chair, and the remaining selected with an open call. The panel met virtually once a week. For all decisions, a simple majority vote was used. A list of clinical questions using the PICO (population, intervention, comparison, and outcome) format was developed at the beginning of the process. For each PICO, two panel members performed a literature search focusing on systematic reviews with a third panellist involved in case of inconsistent results. The panel reassessed the PICOs previously defined as priority in the first set of guidelines and decided to address 49 PICO questions, as 6 of them were discarded as outdated/non-clinically relevant. The "Grading of Recommendations Assessment, Development and Evaluation(GRADE)-adoption, adaptation, and de novo development of recommendations (ADOLOPMENT)" evidence-to-decision framework was utilized to produce the guidelines. QUESTIONS ADDRESSED BY THE GUIDELINE AND RECOMMENDATIONS After literature search, we updated 16 PICO questions; these PICOs address the use of antigen-based assays among symptomatic and asymptomatic patients with different ages, COVID-19 severity status or risk for severe COVID-19, time since onset of symptoms/contact with an infectious case, and finally, types of biomaterials used.
Collapse
Affiliation(s)
- Paraskevi C Fragkou
- First Department of Critical Care Medicine & Pulmonary Services, Evangelismos General Hospital, National and Kapodistrian University of Athens, Athens, Greece; European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV)
| | - Giulia De Angelis
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Dipartimento di Scienze di Laboratorio e Infettivologiche, Fondazione Policlinico Universitario A. Gemelli IRCCS - 00168, Rome, Italy
| | - Giulia Menchinelli
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Dipartimento di Scienze di Laboratorio e Infettivologiche, Fondazione Policlinico Universitario A. Gemelli IRCCS - 00168, Rome, Italy; Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Fusun Can
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Department of Medical Microbiology, Koc University School of Medicine, Istanbul, Turkey; Koc University IsBank Research Centre for Infectious Diseases (KUISCID), Istanbul, Turkey
| | - Federico Garcia
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Servicio de Microbiología Clínica. Hospital Universitario Clínico San Cecilio. Instituto de Investigación Biosanitaria, Ibs.GRANADA, Granada, Spain; Centro de Investigación Biomédicaen Red Enfermedades Infecciosas (CIBERINFEC), ISCIII, Madrid, Spain
| | - Florence Morfin-Sherpa
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Laboratory of Virology, Institut des Agents Infectieux, National Reference Centre for respiratory viruses, Hospices Civils de Lyon, Université Claude Bernard Lyon1, Lyon, France
| | - Dimitra Dimopoulou
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Second Department of Paediatrics, "P. and A. Kyriakou" Children's Hospital, National and Kapodistrian University of Athens, Athens, Greece
| | | | - Silvia Zelli
- Dipartimento di Scienze di Laboratorio e Infettivologiche, Fondazione Policlinico Universitario A. Gemelli IRCCS - 00168, Rome, Italy
| | - Adolfo de Salazar
- Servicio de Microbiología Clínica. Hospital Universitario Clínico San Cecilio. Instituto de Investigación Biosanitaria, Ibs.GRANADA, Granada, Spain; Centro de Investigación Biomédicaen Red Enfermedades Infecciosas (CIBERINFEC), ISCIII, Madrid, Spain
| | - Rieke Reiter
- Institute of Laboratory Medicine, Universities of Giessen and Marburg Lung Centre (UGMLC), Philipps University Marburg, German Centre for Lung Research (DZL), Marburg, Germany
| | - Hannah Janocha
- Institute of Laboratory Medicine, Universities of Giessen and Marburg Lung Centre (UGMLC), Philipps University Marburg, German Centre for Lung Research (DZL), Marburg, Germany
| | | | - Jimmy Omony
- Institute for Asthma and Allergy Prevention (IAP), Helmholtz Zentrum Munich, German Research Centre for Environmental Health (GmbH), Munich, Germany
| | - Chrysanthi Skevaki
- European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Respiratory Viruses (ESGREV); Institute of Laboratory Medicine, Universities of Giessen and Marburg Lung Centre (UGMLC), Philipps University Marburg, German Centre for Lung Research (DZL), Marburg, Germany.
| |
Collapse
|
11
|
Clinical Validation of GenBody COVID-19 Ag, Nasal and Nasopharyngeal Rapid Antigen Tests for Detection of SARS-CoV-2 in European Adult Population. Biomedicines 2023; 11:biomedicines11020493. [PMID: 36831028 PMCID: PMC9953360 DOI: 10.3390/biomedicines11020493] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/02/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023] Open
Abstract
Accurate and rapid identification of COVID-19 is critical for effective patient treatment and disease outcomes, as well as the prevention of SARS-CoV-2 transmission. Rapid antigen tests (RATs) for identifying SARS-CoV-2 are simpler, faster and less expensive than molecular assays. Any new product to be considered a medical device is subject to evaluation and data analysis to verify the in vitro diagnostic ability to achieve its intended purpose. Clinical validation of such a test is a prerequisite before clinical application. This study was a clinical validation on adult Europeans of GenBody COVID-19 Ag, nasal and nasopharyngeal RATs. A set of 103 positive and 301 negative from nose and nasopharynx samples confirmed by RT-qPCR were examined. The tests were safe to use and showed 100% specificity in both specimens, and high sensitivity of 94.17% (95%CI 87.75% to 97.83%) and 97.09% (95%CI 91.72% to 99.4%), respectively. The parameters were significantly better for samples with higher virus loads (the highest for CT ≤ 25). The GenBody COVID-19 Ag RATs are inexpensive (compared to RT-qPCR), reliable and rapid with high sensitivity and specificity, making them suitable for diagnosis and timely isolation and treatment of COVID-19 patients, contributing to the better control of virus spread.
Collapse
|
12
|
Ye Q, Zhang Z, Liu J, Wang X. Screen-printed electrode-based biosensors modified with functional nucleic acid probes and their applications in this pandemic age: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2961-2975. [PMID: 35913361 DOI: 10.1039/d2ay00666a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrochemical methodology has probably been the most used sensing platform in the past few years as they provide superior advantages. In particular, screen-printed electrode (SPE)-based sensing applications stand out as they provide extraordinary miniaturized but robust and user-friendly detection system. In this context, we are focusing on the modification of SPE with functional nucleic acid probes and nanostructures to improve the electrochemical detection performance in versatile sensing applications, particularly in the fight against the COVID-19 pandemic. Aptamers are immobilized on the electrode surface to detect non-nucleic acid targets and complementary probes to recognize and capture nucleic acid targets. In a step further, SPE-based biosensors with the modification of self-assembled DNA nanostructures are emphasized as they offer great potential for the interface engineering of the electrode surface and promote the excellent performance of various interface reactions. By equipping with a portable potentiostat and a smartphone monitoring device, the realization of this SPE-based miniaturized diagnostic system for the further requirement of fast and POC detection is revealed. Finally, more novel and excellent works are previewed and future perspectives in this field are mentioned.
Collapse
Affiliation(s)
- Qingqing Ye
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Zhenqi Zhang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Jian Liu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Xuyao Wang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| |
Collapse
|
13
|
Dinnes J, Sharma P, Berhane S, van Wyk SS, Nyaaba N, Domen J, Taylor M, Cunningham J, Davenport C, Dittrich S, Emperador D, Hooft L, Leeflang MM, McInnes MD, Spijker R, Verbakel JY, Takwoingi Y, Taylor-Phillips S, Van den Bruel A, Deeks JJ. Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev 2022; 7:CD013705. [PMID: 35866452 PMCID: PMC9305720 DOI: 10.1002/14651858.cd013705.pub3] [Citation(s) in RCA: 87] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Accurate rapid diagnostic tests for SARS-CoV-2 infection would be a useful tool to help manage the COVID-19 pandemic. Testing strategies that use rapid antigen tests to detect current infection have the potential to increase access to testing, speed detection of infection, and inform clinical and public health management decisions to reduce transmission. This is the second update of this review, which was first published in 2020. OBJECTIVES To assess the diagnostic accuracy of rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection. We consider accuracy separately in symptomatic and asymptomatic population groups. Sources of heterogeneity investigated included setting and indication for testing, assay format, sample site, viral load, age, timing of test, and study design. SEARCH METHODS We searched the COVID-19 Open Access Project living evidence database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) on 08 March 2021. We included independent evaluations from national reference laboratories, FIND and the Diagnostics Global Health website. We did not apply language restrictions. SELECTION CRITERIA We included studies of people with either suspected SARS-CoV-2 infection, known SARS-CoV-2 infection or known absence of infection, or those who were being screened for infection. We included test accuracy studies of any design that evaluated commercially produced, rapid antigen tests. We included evaluations of single applications of a test (one test result reported per person) and evaluations of serial testing (repeated antigen testing over time). Reference standards for presence or absence of infection were any laboratory-based molecular test (primarily reverse transcription polymerase chain reaction (RT-PCR)) or pre-pandemic respiratory sample. DATA COLLECTION AND ANALYSIS We used standard screening procedures with three people. Two people independently carried out quality assessment (using the QUADAS-2 tool) and extracted study results. Other study characteristics were extracted by one review author and checked by a second. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test, and pooled data using the bivariate model. We investigated heterogeneity by including indicator variables in the random-effects logistic regression models. We tabulated results by test manufacturer and compliance with manufacturer instructions for use and according to symptom status. MAIN RESULTS We included 155 study cohorts (described in 166 study reports, with 24 as preprints). The main results relate to 152 evaluations of single test applications including 100,462 unique samples (16,822 with confirmed SARS-CoV-2). Studies were mainly conducted in Europe (101/152, 66%), and evaluated 49 different commercial antigen assays. Only 23 studies compared two or more brands of test. Risk of bias was high because of participant selection (40, 26%); interpretation of the index test (6, 4%); weaknesses in the reference standard for absence of infection (119, 78%); and participant flow and timing 41 (27%). Characteristics of participants (45, 30%) and index test delivery (47, 31%) differed from the way in which and in whom the test was intended to be used. Nearly all studies (91%) used a single RT-PCR result to define presence or absence of infection. The 152 studies of single test applications reported 228 evaluations of antigen tests. Estimates of sensitivity varied considerably between studies, with consistently high specificities. Average sensitivity was higher in symptomatic (73.0%, 95% CI 69.3% to 76.4%; 109 evaluations; 50,574 samples, 11,662 cases) compared to asymptomatic participants (54.7%, 95% CI 47.7% to 61.6%; 50 evaluations; 40,956 samples, 2641 cases). Average sensitivity was higher in the first week after symptom onset (80.9%, 95% CI 76.9% to 84.4%; 30 evaluations, 2408 cases) than in the second week of symptoms (53.8%, 95% CI 48.0% to 59.6%; 40 evaluations, 1119 cases). For those who were asymptomatic at the time of testing, sensitivity was higher when an epidemiological exposure to SARS-CoV-2 was suspected (64.3%, 95% CI 54.6% to 73.0%; 16 evaluations; 7677 samples, 703 cases) compared to where COVID-19 testing was reported to be widely available to anyone on presentation for testing (49.6%, 95% CI 42.1% to 57.1%; 26 evaluations; 31,904 samples, 1758 cases). Average specificity was similarly high for symptomatic (99.1%) or asymptomatic (99.7%) participants. We observed a steady decline in summary sensitivities as measures of sample viral load decreased. Sensitivity varied between brands. When tests were used according to manufacturer instructions, average sensitivities by brand ranged from 34.3% to 91.3% in symptomatic participants (20 assays with eligible data) and from 28.6% to 77.8% for asymptomatic participants (12 assays). For symptomatic participants, summary sensitivities for seven assays were 80% or more (meeting acceptable criteria set by the World Health Organization (WHO)). The WHO acceptable performance criterion of 97% specificity was met by 17 of 20 assays when tests were used according to manufacturer instructions, 12 of which demonstrated specificities above 99%. For asymptomatic participants the sensitivities of only two assays approached but did not meet WHO acceptable performance standards in one study each; specificities for asymptomatic participants were in a similar range to those observed for symptomatic people. At 5% prevalence using summary data in symptomatic people during the first week after symptom onset, the positive predictive value (PPV) of 89% means that 1 in 10 positive results will be a false positive, and around 1 in 5 cases will be missed. At 0.5% prevalence using summary data for asymptomatic people, where testing was widely available and where epidemiological exposure to COVID-19 was suspected, resulting PPVs would be 38% to 52%, meaning that between 2 in 5 and 1 in 2 positive results will be false positives, and between 1 in 2 and 1 in 3 cases will be missed. AUTHORS' CONCLUSIONS Antigen tests vary in sensitivity. In people with signs and symptoms of COVID-19, sensitivities are highest in the first week of illness when viral loads are higher. Assays that meet appropriate performance standards, such as those set by WHO, could replace laboratory-based RT-PCR when immediate decisions about patient care must be made, or where RT-PCR cannot be delivered in a timely manner. However, they are more suitable for use as triage to RT-PCR testing. The variable sensitivity of antigen tests means that people who test negative may still be infected. Many commercially available rapid antigen tests have not been evaluated in independent validation studies. Evidence for testing in asymptomatic cohorts has increased, however sensitivity is lower and there is a paucity of evidence for testing in different settings. Questions remain about the use of antigen test-based repeat testing strategies. Further research is needed to evaluate the effectiveness of screening programmes at reducing transmission of infection, whether mass screening or targeted approaches including schools, healthcare setting and traveller screening.
Collapse
Affiliation(s)
- Jacqueline Dinnes
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Pawana Sharma
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Sarah Berhane
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Susanna S van Wyk
- Centre for Evidence-based Health Care, Epidemiology and Biostatistics, Department of Global Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Nicholas Nyaaba
- Infectious Disease Unit, 37 Military Hospital, Cantonments, Ghana
| | - Julie Domen
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Melissa Taylor
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Liverpool, UK
| | - Jane Cunningham
- Global Malaria Programme, World Health Organization, Geneva, Switzerland
| | - Clare Davenport
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | | | | | - Lotty Hooft
- Cochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
| | - Mariska Mg Leeflang
- Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, Netherlands
| | | | - René Spijker
- Cochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands
- Medical Library, Amsterdam UMC, University of Amsterdam, Amsterdam Public Health, Amsterdam, Netherlands
| | - Jan Y Verbakel
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Yemisi Takwoingi
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| | - Sian Taylor-Phillips
- Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, UK
| | - Ann Van den Bruel
- Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
| | - Jonathan J Deeks
- Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK
| |
Collapse
|
14
|
Dai S, Li J, Li J, Li L, Shi L, Cao L, Zhong X, Liu W, Wang Y, Ma L. Analysis of 4 cases of children with false-positive results of novel coronavirus-specific antibody. BMC Pediatr 2022; 22:372. [PMID: 35765042 PMCID: PMC9237983 DOI: 10.1186/s12887-022-03425-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 06/17/2022] [Indexed: 12/15/2022] Open
Abstract
Abstract
Background
This study attempts to explore the influencing factors and solutions of the colloidal gold method for novel coronavirus (2019-nCoV)-specific IgM/IgG antibody detection, summarize the clinical experience and perfect the examination process, improving the application value of antibody detection in COVID-19 diagnosis.
Methods
A total of 13,329 peripheral whole blood/plasma/serum samples were obtained for COVID-19 screening from children who visited the Children's Hospital of the Capital Institute of Pediatrics outpatient clinic from April 22, 2020, to November 30, 2020. The colloidal gold method was adopted for 2019-nCoV-specific IgM/IgG antibody detection. The virus nucleic acid test results, clinical records, and serum protein fingerprint results of antibody-positive patients were collected.
Results
All samples were examined using the colloidal gold method with two 2019-nCoV-specific IgM/IgG antibody detection kits. Four patients were tested single antibody-positive using both kits. The details were as follows: two cases of IgM ( +) and IgG (-) using plasma and serum separately, two cases of IgM (-) and IgG ( +) using serum and whole blood. The protein fingerprinting results and nucleic acid tests of 2019-nCoV antibodies were negative in the 4 cases. Considering the epidemiological history, clinical manifestations, and test results, these 4 children were ruled out for 2019-nCoV infection.
Conclusions
When the colloidal gold method was used to detect 2019-nCoV-specific IgM/IgG antibodies, it was important to ascertain the test results as precisely as possible. Specimen type and patient history may interfere with the diagnosis.
Collapse
|
15
|
Tapari A, Braliou GG, Papaefthimiou M, Mavriki H, Kontou PI, Nikolopoulos GK, Bagos PG. Performance of Antigen Detection Tests for SARS-CoV-2: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:1388. [PMID: 35741198 PMCID: PMC9221910 DOI: 10.3390/diagnostics12061388] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/20/2022] [Accepted: 05/24/2022] [Indexed: 11/16/2022] Open
Abstract
Coronavirus disease 2019 (COVID-19) initiated global health care challenges such as the necessity for new diagnostic tests. Diagnosis by real-time PCR remains the gold-standard method, yet economical and technical issues prohibit its use in points of care (POC) or for repetitive tests in populations. A lot of effort has been exerted in developing, using, and validating antigen-based tests (ATs). Since individual studies focus on few methodological aspects of ATs, a comparison of different tests is needed. Herein, we perform a systematic review and meta-analysis of data from articles in PubMed, medRxiv and bioRxiv. The bivariate method for meta-analysis of diagnostic tests pooling sensitivities and specificities was used. Most of the AT types for SARS-CoV-2 were lateral flow immunoassays (LFIA), fluorescence immunoassays (FIA), and chemiluminescence enzyme immunoassays (CLEIA). We identified 235 articles containing data from 220,049 individuals. All ATs using nasopharyngeal samples show better performance than those with throat saliva (72% compared to 40%). Moreover, the rapid methods LFIA and FIA show about 10% lower sensitivity compared to the laboratory-based CLEIA method (72% compared to 82%). In addition, rapid ATs show higher sensitivity in symptomatic patients compared to asymptomatic patients, suggesting that viral load is a crucial parameter for ATs performed in POCs. Finally, all methods perform with very high specificity, reaching around 99%. LFIA tests, though with moderate sensitivity, appear as the most attractive method for use in POCs and for performing seroprevalence studies.
Collapse
Affiliation(s)
- Anastasia Tapari
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Georgia G. Braliou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Maria Papaefthimiou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Helen Mavriki
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | - Panagiota I. Kontou
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| | | | - Pantelis G. Bagos
- Department of Computer Science and Biomedical Informatics, University of Thessaly, 35131 Lamia, Greece; (A.T.); (G.G.B.); (M.P.); (H.M.); (P.I.K.)
| |
Collapse
|
16
|
Li X, Xiong M, Deng Q, Guo X, Li Y. The utility of SARS-CoV-2 nucleocapsid protein in laboratory diagnosis. J Clin Lab Anal 2022; 36:e24534. [PMID: 35657146 PMCID: PMC9279953 DOI: 10.1002/jcla.24534] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 04/01/2022] [Accepted: 05/19/2022] [Indexed: 11/10/2022] Open
Abstract
Background The Coronavirus Disease 2019 (COVID‐19) is caused by the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2), which has now become a global pandemic owing to its high transmissibility. The SARS‐CoV‐2 nucleocapsid protein tests are playing an important role in screening and diagnosing patients with COVID‐19, and studies about the utility of SARS‐CoV‐2 nucleocapsid protein tests are increasing now. Methods In this review, all the relevant original studies were assessed by searching in electronic databases including Scopus, Pubmed, Embase, and Web of Science. “SARS‐CoV‐2”, “COVID‐19”, “nucleocapsid protein”, and “antigen detection” were used as keywords. Results In this review, we summarized the utility of SARS‐CoV‐2 nucleocapsid protein in laboratory diagnosis. Among the representative researches, this review analyzed, the sensitivity of SARS‐CoV‐2 nucleocapsid protein detection varies from 13% to 87.9%, while the specificity could almost reach 100% in most studies. As a matter of fact, the sensitivity is around 50% and could be higher or lower due to the influential factors. Conclusion It is well suggested that SARS‐CoV‐2 nucleocapsid protein is a convenient method with a short turnaround time of about half an hour, and the presence of N antigen is positively related to viral transmissibility, indicating that SARS‐CoV‐2 N protein immunoassays contribute to finding out those infected people rapidly and segregating them from the uninfected people.
Collapse
Affiliation(s)
- Xinwei Li
- Class 11, Grade 2018, Medical School of Zhengzhou University, Zhengzhou, China
| | - Mengyuan Xiong
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China
| | - Qiaoling Deng
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China
| | - Xiaobing Guo
- Department of Laboratory Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yirong Li
- Department of Laboratory Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China
| |
Collapse
|
17
|
Brümmer LE, Katzenschlager S, McGrath S, Schmitz S, Gaeddert M, Erdmann C, Bota M, Grilli M, Larmann J, Weigand MA, Pollock NR, Macé A, Erkosar B, Carmona S, Sacks JA, Ongarello S, Denkinger CM. Accuracy of rapid point-of-care antigen-based diagnostics for SARS-CoV-2: An updated systematic review and meta-analysis with meta-regression analyzing influencing factors. PLoS Med 2022; 19:e1004011. [PMID: 35617375 PMCID: PMC9187092 DOI: 10.1371/journal.pmed.1004011] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 06/10/2022] [Accepted: 05/04/2022] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. METHODS AND FINDINGS We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and <25, compared to 54.4% [95% CI 47.3 to 61.5] and 18.7% [95% CI 13.9 to 23.4] for Ct-values ≥25 and ≥30) and was estimated to increase by 2.9 percentage points (95% CI 1.7 to 4.0) for every unit decrease in mean Ct-value when adjusting for testing procedure and patients' symptom status. Concordantly, we found the mean Ct-value to be lower for true positive (22.2 [95% CI 21.5 to 22.8]) compared to false negative (30.4 [95% CI 29.7 to 31.1]) results. Testing in the first week from symptom onset resulted in substantially higher sensitivity (81.9% [95% CI 77.7 to 85.5]) compared to testing after 1 week (51.8%, 95% CI 41.5 to 61.9). Similarly, sensitivity was higher in symptomatic (76.2% [95% CI 73.3 to 78.9]) compared to asymptomatic (56.8% [95% CI 50.9 to 62.4]) persons. However, both effects were mainly driven by the Ct-value of the sample. With regards to sample type, highest sensitivity was found for nasopharyngeal (NP) and combined NP/oropharyngeal samples (70.8% [95% CI 68.3 to 73.2]), as well as in anterior nasal/mid-turbinate samples (77.3% [95% CI 73.0 to 81.0]). Our analysis was limited by the included studies' heterogeneity in viral load assessment and sample origination. CONCLUSIONS Ag-RDTs detect most of the individuals infected with SARS-CoV-2, and almost all (>90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.
Collapse
Affiliation(s)
- Lukas E. Brümmer
- Division of Infectious Disease and Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Sean McGrath
- Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, Massachusetts, United States of America
| | - Stephani Schmitz
- Department of Developmental Biology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Mary Gaeddert
- Division of Infectious Disease and Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Marc Bota
- Agaplesion Bethesda Hospital, Hamburg, Germany
| | - Maurizio Grilli
- Library, University Medical Center Mannheim, Mannheim, Germany
| | - Jan Larmann
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus A. Weigand
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Nira R. Pollock
- Department of Laboratory Medicine, Boston Children’s Hospital, Boston, Massachusetts, United States of America
| | | | | | | | | | | | - Claudia M. Denkinger
- Division of Infectious Disease and Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
- German Center for Infection Research (DZIF), partner site Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
18
|
Khalid MF, Selvam K, Jeffry AJN, Salmi MF, Najib MA, Norhayati MN, Aziah I. Performance of Rapid Antigen Tests for COVID-19 Diagnosis: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2022; 12:diagnostics12010110. [PMID: 35054277 PMCID: PMC8774565 DOI: 10.3390/diagnostics12010110] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 12/30/2021] [Accepted: 12/30/2021] [Indexed: 02/04/2023] Open
Abstract
The identification of viral RNA using reverse transcription quantitative polymerase chain reaction (RT-qPCR) is the gold standard for identifying an infection caused by SARS-CoV-2. The limitations of RT-qPCR such as requirement of expensive instruments, trained staff and laboratory facilities led to development of rapid antigen tests (RATs). The performance of RATs has been widely evaluated and found to be varied in different settings. The present systematic review aims to evaluate the pooled sensitivity and specificity of the commercially available RATs. This review was registered on PROSPERO (registration number: CRD42021278105). Literature search was performed through PubMed, Embase and Cochrane COVID-19 Study Register to search studies published up to 26 August 2021. The overall pooled sensitivity and specificity of RATs and subgroup analyses were calculated. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to assess the risk of bias in each study. The overall pooled sensitivity and specificity of RATs were 70% (95% CI: 69–71) and 98% (95% CI: 98–98), respectively. In subgroup analyses, nasal swabs showed the highest sensitivity of 83% (95% CI: 80–86) followed by nasopharyngeal swabs 71% (95% CI: 70–72), throat swabs 69% (95% CI: 63–75) and saliva 68% (95% CI: 59–77). Samples from symptomatic patients showed a higher sensitivity of 82% (95% CI: 82–82) as compared to asymptomatic patients at 68% (95% CI: 65–71), while a cycle threshold (Ct) value ≤25 showed a higher sensitivity of 96% (95% CI: 95–97) as compared to higher Ct value. Although the sensitivity of RATs needs to be enhanced, it may still be a viable option in places where laboratory facilities are lacking for diagnostic purposes in the early phase of disease.
Collapse
Affiliation(s)
- Muhammad Fazli Khalid
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Kasturi Selvam
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Alfeq Jazree Nashru Jeffry
- Faculty of Resource Science and Technology (FRST), Universiti Malaysia Sarawak, Kota Samarahan 94300, Sarawak, Malaysia; (A.J.N.J.); (M.F.S.)
| | - Mohamad Fazrul Salmi
- Faculty of Resource Science and Technology (FRST), Universiti Malaysia Sarawak, Kota Samarahan 94300, Sarawak, Malaysia; (A.J.N.J.); (M.F.S.)
| | - Mohamad Ahmad Najib
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
| | - Mohd Noor Norhayati
- Department of Family Medicine, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia;
| | - Ismail Aziah
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (M.F.K.); (K.S.); (M.A.N.)
- Correspondence:
| |
Collapse
|
19
|
A Smartphone-Based Detection Method of Colloidal Gold Immunochromatographic Strip. PHOTONICS 2021. [DOI: 10.3390/photonics8120576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The outbreak of the new coronavirus (SARS-CoV-2) infection has become a global public health crisis. Antigen detection strips (colloidal gold) can be widely used in novel coronavirus clinical screening and can even be extended to home self-testing, which provides a practical and effective way for people to obtain health status information away from the crowd. In this paper, a colloidal gold detection system without complex devices is proposed, which is based on smartphone usage along with a mobile-phone software embedded with normalization algorithms and a special designed background paper. The basic principle of the device relies on image processing. First, the data of the green channel of the image captured by a smartphone are selected to be processed. Second, the calibration curves are established using standard black and white card, and the calibration values under different detection environments are obtained by calibration curves. Finally, to verify the validity of the proposed method, various standard solutions with different concentrations are tested. Results show that this method can eliminate the influence of different environments on the test results, the test results in different detection environments have good stability and the variation coefficients are less than 5%. It fully proves that the detection system designed in this paper can detect the result of colloidal gold immunochromatographic strip in time, conveniently and accurately in different environments.
Collapse
|