1
|
Kong X, Cheng L, Dong Z, Huang Y, Xue X, Wang Z, Wang Y, Zang X, Qian H, Chang L, Wang Y. Rapid Cryptococcus electroporated-lysis and sensitive detection on a miniaturized platform. Biosens Bioelectron 2024; 250:116096. [PMID: 38316089 DOI: 10.1016/j.bios.2024.116096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 01/28/2024] [Accepted: 01/31/2024] [Indexed: 02/07/2024]
Abstract
Fast and accurate detection of Cryptococcus and precise differentiation of its subtypes is of great significance in protecting people from cryptococcal disease and preventing its spread in populations. However, traditional Cryptococcus identification and detection techniques still face significant challenges in achieving high analysis speed as well as high sensitivity. In this work, we report an electric microfluidic biochip. Compared to conventional methods that take several hours or even a day, this chip can detect Cryptococcus within 20 min, and achieve its maximum detection limit within 1 h, with the ability to differentiate between the Cryptococcus neoformans (NEO) and rare Cryptococcus gattii (GAT) efficiently, which accounts for nearly 100%. This device integrated two functional zones of an electroporation lysis (EL) zone for rapid cell lysis (<30 s) and an electrochemical detection (ED) zone for sensitive analysis of the released nucleic acids. The EL zone adopted a design of microelectrode arrays, which obtains a large electric field intensity at the constriction of the microchannel, addressing the safety concerns associated with high-voltage lysis. The device enables a limit of detection (LOD) of 60 pg/mL for NEO and 100 pg/mL for GAT through the modification of nanocomposites and specific probes. In terms of the detection time and sensitivity, the integrated microfluidic biochip demonstrates broad potential in Cryptococcus diagnosis and disease prevention.
Collapse
Affiliation(s)
- Xiangzhu Kong
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China
| | - Long Cheng
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China
| | - Zaizai Dong
- School of Engineering Medicine, Beihang University, Beijing, 100191, China; Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Yemei Huang
- Department of Respiratory and Critical Care, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, China
| | - Xinying Xue
- Department of Respiratory and Critical Care, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, China; Affiliated Hospital of Weifang Medical University, Weifang, 261000, China
| | - Zhiying Wang
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Yusen Wang
- Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Xuelei Zang
- Department of Respiratory and Critical Care, Beijing Shijitan Hospital, Capital Medical University, Beijing, 100038, China
| | - Haisheng Qian
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China; School of Basic Medical Sciences, Anhui Provincial Institute of Translational Medicine, Anhui Medical University, Hefei, 230032, China.
| | - Lingqian Chang
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China; Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
| | - Yang Wang
- School of Engineering Medicine, Beihang University, Beijing, 100191, China.
| |
Collapse
|