Lui C, Polster R, Bullen J, Baqui Z, Ilaslan H, Neill M, Simpfendorfer C, Altahawi F, Polster J. Smartphone application with 3D-printed needle guide for faster and more accurate CT-guided interventions in a phantom. Skeletal Radiol 2024; 53:567-573. [PMID: 37725165 DOI: 10.1007/s00256-023-04453-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 09/06/2023] [Accepted: 09/06/2023] [Indexed: 09/21/2023]
Abstract
OBJECTIVE This study is to determine whether a needle guidance device combining a 3D-printed component with a smartphone would decrease the number of passes and time required to perform a standard CT-guided needle procedure in a phantom study. MATERIALS AND METHODS A 3D-printed mechanical guide with built-in apertures for various needle sizes was designed and printed. It was mounted on a smartphone and used to direct commercially available spring-loaded biopsy devices. A smartphone software application was developed to use the phone's sensors to provide the real-time location of a lesion in space, based on parameters derived from preprocedural CT images. The physical linkage of the guide, smartphone, and needle allowed the operator to manipulate the assembly as a single unit, with real-time graphical representation of the lesion shown on the smartphone display. Two radiology trainees and 3 staff radiologists targeted 5 lesions with and without the device (50 total procedures). The number of passes and time taken to reach each lesion were determined. RESULTS Use of the smartphone needle guide decreased the mean number of passes (with guide, 1.8; without guide, 3.4; P < 0.001) and mean time taken (with guide, 1.6 min; without guide, 2.7 min; P = 0.005) to perform a standard CT-guided procedure. On average, the decreases in number of passes and procedure time were more pronounced among trainees (P < 0.001). CONCLUSION The combination of a mechanical guide and smartphone can reduce the number of needle passes and the amount of time needed to reach a lesion in a phantom for both trainees and experienced radiologists.
Collapse
Affiliation(s)
- Christopher Lui
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA.
| | - Rylan Polster
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Jennifer Bullen
- Quantitative Health Sciences, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Zeeshan Baqui
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Hakan Ilaslan
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Matthew Neill
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Claus Simpfendorfer
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Faysal Altahawi
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| | - Joshua Polster
- Imaging Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH, 44195, USA
| |
Collapse
|
2
|
Gherman B, Hajjar NA, Tucan P, Radu C, Vaida C, Mois E, Burz A, Pisla D. Risk Assessment-Oriented Design of a Needle Insertion Robotic System for Non-Resectable Liver Tumors. Healthcare (Basel) 2022; 10:389. [PMID: 35207006 PMCID: PMC8872014 DOI: 10.3390/healthcare10020389] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/19/2022] [Accepted: 02/15/2022] [Indexed: 11/16/2022] Open
Abstract
Medical robotics is a highly challenging and rewarding field of research, especially in the development of minimally invasive solutions for the treatment of the worldwide leading cause of death, cancer. The aim of the paper is to provide a design methodology for the development of a safe and efficient medical robotic system for the minimally invasive, percutaneous, targeted treatment of hepatocellular carcinoma, which can be extended with minimal modification for other types of abdominal cancers. Using as input a set of general medical requirements to comply with currently applicable standards, and a set of identified hazards and failure modes, specific methods, such as the Analytical Hierarchy Prioritization, Risk Analysis and fuzzy logic Failure Modes and Effect Analysis have been used within a stepwise approach to help in the development of a medical device targeting the insertion of multiple needles in brachytherapy procedures. The developed medical device, which is visually guided using CT scanning, has been tested for validation in a medical environment using a human-size ballistic gel liver, with promising results. These prove that the robotic system can be used for the proposed medical task, while the modular approach increases the chances of acceptance.
Collapse
Affiliation(s)
- Bogdan Gherman
- CESTER—Research Center for Industrial Robots Simulation and Testing, Technical University of Cluj-Napoca, Bulevardul Muncii Street, No. 103-105, 400641 Cluj-Napoca, Romania; (B.G.); (P.T.); (C.V.); (A.B.)
| | - Nadim Al Hajjar
- “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology Cluj-Napoca, Croitorilor Street, No. 19-21, 400162 Cluj-Napoca, Romania; (N.A.H.); (C.R.); (E.M.)
| | - Paul Tucan
- CESTER—Research Center for Industrial Robots Simulation and Testing, Technical University of Cluj-Napoca, Bulevardul Muncii Street, No. 103-105, 400641 Cluj-Napoca, Romania; (B.G.); (P.T.); (C.V.); (A.B.)
| | - Corina Radu
- “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology Cluj-Napoca, Croitorilor Street, No. 19-21, 400162 Cluj-Napoca, Romania; (N.A.H.); (C.R.); (E.M.)
| | - Calin Vaida
- CESTER—Research Center for Industrial Robots Simulation and Testing, Technical University of Cluj-Napoca, Bulevardul Muncii Street, No. 103-105, 400641 Cluj-Napoca, Romania; (B.G.); (P.T.); (C.V.); (A.B.)
| | - Emil Mois
- “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology Cluj-Napoca, Croitorilor Street, No. 19-21, 400162 Cluj-Napoca, Romania; (N.A.H.); (C.R.); (E.M.)
| | - Alin Burz
- CESTER—Research Center for Industrial Robots Simulation and Testing, Technical University of Cluj-Napoca, Bulevardul Muncii Street, No. 103-105, 400641 Cluj-Napoca, Romania; (B.G.); (P.T.); (C.V.); (A.B.)
| | - Doina Pisla
- CESTER—Research Center for Industrial Robots Simulation and Testing, Technical University of Cluj-Napoca, Bulevardul Muncii Street, No. 103-105, 400641 Cluj-Napoca, Romania; (B.G.); (P.T.); (C.V.); (A.B.)
| |