1
|
Chauvet R, Martin A, Rovt J, Petel O, Ouellet S, Westover L, Dennison CR. Development of a Detailed Finite Element Model of the BIPED MK2 and Verification of Fidelity in Two Cases of Blunt Impact. Ann Biomed Eng 2025; 53:1226-1246. [PMID: 40057650 DOI: 10.1007/s10439-024-03652-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 11/13/2024] [Indexed: 04/19/2025]
Abstract
Physical surrogates of the human head are commonly used to model cranial impacts, assess helmet efficacy and assess likelihood of head injuries. The Brain Injury Protection Evaluation Device (BIPED mk2) is a head form that contains a brain simulant, cerebrospinal fluid layer (CSF), connective membranes, a skull and a skin layer, and can be configured to measure kinematics, pressures and strains. In design efforts to increase the biofidelity of surrogates, finite element models play a significant role in assessing design iterations that better mimic the biological response of the head during impact. This study aims to create a digital model of the BIPED mk2 and provide a robust comparison to experimental pressure and strain data, measured from specific impact scenarios. Kinematics from two separate frontal impact experiment campaigns were used to drive the BIPED mk2 finite element model. In the first experiments, brain pressure was extracted from in situ transducers. In the second, brain strain was extracted from post hoc imagery analysis. These pressure and strain data are the basis on which we verify the pressures and strains reported from the finite element model. Pressure and displacement time series responses were compared with experimental data using a CORrelation Analysis (CORA). The average CORA rating for pressure measurements taken at the front brain sensor was 0.701 using the kinematic model inputs and 0.851 for the force model inputs. For the rear brain sensor, the signals were deemed poor fits as the average CORA scores were 0.442 for the kinematic input and 0.255 for the force input. CORA ratings for the comparison of displacement data in the x (anterior-posterior) and z (superior-inferior) directions of the 18 nodes tested resulted in a range of values from 0.012 to 0.936. The results matched best in the interior but were poor along the perimeter of the brain depending on the location of the point in relation to the brain surface. We speculate the mixed findings are due in large part to the simplified CSF model, a potential focus for future model refinement.
Collapse
Affiliation(s)
- Robert Chauvet
- Department of Mechanical Engineering, University of Alberta, 116 St and 85 Ave, Edmonton, AB, T6G 2R3, Canada.
- Biomedical Instrumentation Lab, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada.
| | - Ashton Martin
- Department of Mechanical Engineering, University of Alberta, 116 St and 85 Ave, Edmonton, AB, T6G 2R3, Canada
| | - Jennifer Rovt
- Department of Mechanical and Aerospace Engineering, Carleton University, 1125 Colonel By Dr., Ottawa, ON, K1S 5B6, Canada
| | - Oren Petel
- Department of Mechanical and Aerospace Engineering, Carleton University, 1125 Colonel By Dr., Ottawa, ON, K1S 5B6, Canada
| | - Simon Ouellet
- Defense Research and Development Canada - Valcartier Research Center, 2459 Bravoure Rd., Québec, QC, G3J 1X5, Canada
| | - Lindsey Westover
- Department of Mechanical Engineering, University of Alberta, 116 St and 85 Ave, Edmonton, AB, T6G 2R3, Canada
- Department of Biomedical Engineering, University of Alberta, 116 St and 85 Ave, Edmonton, AB, T6G 2R3, Canada
| | - Christopher R Dennison
- Biomedical Instrumentation Lab, Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
- The Biomechanics and Instrumentation Laboratory, Department of Mechanical Engineering, University of Victoria, 3800 Finnerty Road, Victoria, BC, V8P 5C2, Canada
| |
Collapse
|
2
|
Tenio T, Boakye-Yiadom S. Characterization and selection of a skull surrogate for the development of a biofidelic head model. J Mech Behav Biomed Mater 2024; 158:106680. [PMID: 39153408 DOI: 10.1016/j.jmbbm.2024.106680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 07/30/2024] [Accepted: 08/05/2024] [Indexed: 08/19/2024]
Abstract
This research paper explores the advancement of physical models simulating the human skull-brain complex, focusing on applications in simulating mild Traumatic Brain Injury (mTBI). Existing models, especially head forms, lack biofidelity in accurately representing the native structures of the skull, limiting the understanding of intracranial injury parameters beyond kinematic head accelerations. This study addresses this gap by investigating the use of additive manufacturing (AM) techniques to develop biofidelic skull surrogates. Materials such as Polylactic Acid (PLA), a bone-simulant PLA variant, and Hydroxyapatite-coated Poly(methyl methacrylate) (PMMA) were used to create models tested for their flexural modulus and strength. The trabecular bone regions were simulated by adjusting infill densities (30%, 50%, 80%) and print raster directions, optimizing manufacturing parameters for biofidelic performance. Among the tested materials, PLA and its bone-simulating variant printed at 80% infill density with a side (tangential) print orientation demonstrated the closest approximation to the mechanical properties of cranial bone, yielding a mean flexural modulus of 1337.2 MPa and a mean ultimate strength of 56.9 MPa. Statistical analyses showed that infill density significantly influenced the moduli and strength of the printed simulants. Digital Image Correlation (DIC) corroborated the comparable performance of the simulants, showing similar strain and displacement behaviors to native skull bone. Notably, the performance of the manufactured cortical and trabecular regions underscored their crucial role in achieving biofidelity, with the trabecular structure providing critical dampening effects when the native bone is loaded. This study establishes PLA, particularly its bone-simulant variant, as an optimal candidate for cranial bone simulants, offering significant potential for developing more accurate biofidelic head models in mTBI research.
Collapse
Affiliation(s)
- Tristan Tenio
- Lassonde School of Engineering Mechanical Engineering Department , York University , Bergeron Building of Engineering Excellence , 11 Arboretum Lane, North York, ON, M3J2S5, Canada.
| | - Solomon Boakye-Yiadom
- Lassonde School of Engineering Mechanical Engineering Department , York University , Bergeron Building of Engineering Excellence , 11 Arboretum Lane, North York, ON, M3J2S5, Canada
| |
Collapse
|
3
|
Thomas CJH, Dogan F, Johnson CE. Experimental investigation of a viscoelastic liner to reduce under helmet overpressures and shock wave reflections. Front Bioeng Biotechnol 2024; 12:1455324. [PMID: 39280344 PMCID: PMC11392881 DOI: 10.3389/fbioe.2024.1455324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 08/16/2024] [Indexed: 09/18/2024] Open
Abstract
Introduction Shock wave overpressure exposures can result in blast-induced traumatic brain injury (bTBI) in warfighters. Although combat helmets provide protection against blunt impacts, the protection against blast waves is limited due to the observed high overpressures occurring underneath the helmet. One route to enhance these helmets is by incorporating viscoelastic materials into the helmet designs, reducing pressures imposed on the head. This study aims to further investigate this mitigation technique against under-helmet overpressures by adding a viscoelastic liner to the inside of a combat helmet. Methods The liner's effectiveness was evaluated by exposing it to free-field blasts of Composition C-4 at overpressures ranging from 27.5 to 165 kPa (4 - 24 psi) and comparing shock waveform parameters to an unlined helmet. Blasts were conducted using an instrumented manikin equipped with and without a helmet and then with a helmet modified to incorporate a viscoelastic liner. Evaluation of blast exposure results focused on the waveform parameters of peak pressure, impulse and positive phase duration. Results The results show that peak overpressure was higher when wearing a helmet compared to not wearing a helmet. However, the helmet with the viscoelastic liner reduced the average peak overpressures compared to the helmet alone. For the lowest overpressure tested, 27.5 kPa, the helmet liner decreased the overpressure on the top of the head by 37.6%, with reduction reaching 26% at the highest overpressure exposure of 165 kPa. Additionally, the inclusion of the viscoelastic material extended the shock waveforms' duration, reducing the rate the shock wave was applied to the head. The results of this study show the role a helmet and helmet design play in the level of blast exposure imposed on a wearer. The testing and evaluation of these materials hold promise for enhancing helmet design to better protect against bTBI.
Collapse
Affiliation(s)
- Cody J H Thomas
- Mining and Explosives Engineering Department, Missouri University of Science and Technology, Rolla, MO, United States
| | - Fatih Dogan
- Materials Science and Engineering Department, Missouri University of Science and Technology, Rolla, MO, United States
| | - Catherine E Johnson
- Mining and Explosives Engineering Department, Missouri University of Science and Technology, Rolla, MO, United States
| |
Collapse
|
4
|
Numerical Modelling and Simulation Applied to Head Trauma. MATHEMATICAL AND COMPUTATIONAL APPLICATIONS 2021. [DOI: 10.3390/mca26030050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Traumatic brain injury (TBI) is one of the leading causes of death and disability [...]
Collapse
|
5
|
Wahlquist VE, Kaminski TW. Analysis of Head Impact Biomechanics in Youth Female Soccer Players Following the Get aHEAD Safely in Soccer™ Heading Intervention. SENSORS (BASEL, SWITZERLAND) 2021; 21:3859. [PMID: 34204896 PMCID: PMC8199772 DOI: 10.3390/s21113859] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 11/16/2022]
Abstract
The effects of repetitive head impacts associated with soccer heading, especially in the youth population, are unknown. The purpose of this study was to examine balance, neurocognitive function, and head impact biomechanics after an acute bout of heading before and after the Get aHEAD Safely in Soccer™ program intervention. Twelve youth female soccer players wore a Triax SIM-G head impact sensor during two bouts of heading, using a lightweight soccer ball, one before and one after completion of the Get aHEAD Safely in Soccer™ program intervention. Participants completed balance (BESS and SWAY) and neurocognitive function (ImPACT) tests at baseline and after each bout of heading. There were no significant changes in head impact biomechanics, BESS, or ImPACT scores pre- to post-season. Deficits in three of the five SWAY positions were observed from baseline to post-season. Although we expected to see beneficial changes in head impact biomechanics following the intervention, the coaches and researchers observed an improvement in heading technique/form. Lightweight soccer balls would be a beneficial addition to header drills during training as they are safe and help build confidence in youth soccer players.
Collapse
Affiliation(s)
| | - Thomas W. Kaminski
- Athletic Training Research Laboratory, University of Delaware, Newark, DE 19716, USA;
| |
Collapse
|
6
|
Computing Brain White and Grey Matter Injury Severity in a Traumatic Fall. MATHEMATICAL AND COMPUTATIONAL APPLICATIONS 2020. [DOI: 10.3390/mca25030061] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
In the real world, the severity of traumatic injuries is measured using the Abbreviated Injury Scale (AIS). However, the AIS scale cannot currently be computed by using the output from finite element human computer models, which currently rely on maximum principal strains (MPS) to capture serious and fatal injuries. In order to overcome these limitations, a unique Organ Trauma Model (OTM) able to calculate the threat to the life of a brain model at all AIS levels is introduced. The OTM uses a power method, named Peak Virtual Power (PVP), and defines brain white and grey matter trauma responses as a function of impact location and impact speed. This research has considered ageing in the injury severity computation by including soft tissue material degradation, as well as brain volume changes due to ageing. Further, to account for the limitations of the Lagrangian formulation of the brain model in representing hemorrhage, an approach to include the effects of subdural hematoma is proposed and included as part of the predictions. The OTM model was tested against two real-life falls and has proven to correctly predict the post-mortem outcomes. This paper is a proof of concept, and pending more testing, could support forensic studies.
Collapse
|