1
|
Lepp KM, Carter BM, Bain LC, Antonini RE. Umbilical Line Securement Bundle to Reduce Line Loss in the Neonate. Adv Neonatal Care 2024; 24:510-516. [PMID: 39270132 DOI: 10.1097/anc.0000000000001198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2024]
Abstract
BACKGROUND Umbilical line migration not only increases the risks of complications but also results in malposition and, ultimately, loss of the umbilical line. PURPOSE To evaluate the use of an umbilical line securement bundle to reduce unintended line discontinuation after line adjustment in the neonate at a single 40-bed Level IV neonatal intensive care unit. METHODS A pre-post design of 75 neonates, preimplementation (n = 50) and postimplementation (n = 25), was analyzed using data collection from the electronic health record. RESULTS There was a 37.5% absolute reduction in removal of the umbilical line due to malposition after line adjustment utilizing the umbilical line bundle, standardizing the adjustment order, nursing process, and follow-up x-ray evaluation. This absolute reduction has clinical significance although not statistically significant. Provider compliance rates with line adjustment order bundle were 75%, decreasing with additional adjustments (50%). Nursing staff reported comfort with umbilical line management, ranging from 63% to 87% on different tasks. IMPLICATIONS FOR PRACTICE The use of umbilical line bundles reduces rates of line discontinuation due to malposition. The adoption of umbilical line bundles in neonatal intensive care unit practice may help to prevent unintended line discontinuation. IMPLICATIONS FOR RESEARCH There is a need for continued research regarding the use of secondary securement devices for decreased rate of malposition and the timing and methods for surveillance of umbilical line position.
Collapse
Affiliation(s)
- Kirsten M Lepp
- DNP Program, Duke University School of Nursing, and Neonatal Intensive Care Unit, Lucile Packard Children's Hospital Stanford, Palo Alto, California (Dr Lepp); Diversity, Equity, and Inclusion, American Association of Colleges of Nursing, Washington, District of Columbia (Dr Carter); Department of Pediatrics and Neonatology, Stanford University School of Medicine, Palo Alto, California (Dr Bain); and Neonatal Intensive Care Unit, Lucile Packard Children's Hospital Stanford, Palo Alto, California (Mrs Antonini)
| | | | | | | |
Collapse
|
2
|
Dai Z, Zhong X, Chen Q, Chen Y, Pan S, Ye H, Tang X. Identification of Neonatal Factors Predicting Pre-Discharge Mortality in Extremely Preterm or Extremely Low Birth Weight Infants: A Historical Cohort Study. CHILDREN (BASEL, SWITZERLAND) 2024; 11:1453. [PMID: 39767882 PMCID: PMC11674047 DOI: 10.3390/children11121453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2024] [Revised: 11/24/2024] [Accepted: 11/26/2024] [Indexed: 01/11/2025]
Abstract
BACKGROUND/OBJECTIVES This study identified early neonatal factors predicting pre-discharge mortality among extremely preterm infants (EPIs) or extremely low birth weight infants (ELBWIs) in China, where data are scarce. METHODS We conducted a retrospective analysis of 211 (92 deaths) neonates born <28 weeks of gestation or with a birth weight <1000 g, admitted to University Affiliated Hospitals from 2013 to 2024 in Guangzhou, China. Data on 26 neonatal factors before the first 24 h of life and pre-discharge mortality were collected. LASSO-Cox regression was employed to screen predictive factors, followed by stepwise Cox regression to develop the final mortality prediction model. The model's performance was evaluated using the area under the curve (AUC) of the receiver operating characteristic, calibration curves, and decision curve analysis. RESULTS The LASSO-Cox model identified 13 predictors that showed strong predictive accuracy (AUC: 0.806/0.864 in the training/validation sets), with sensitivity and specificity rates above 70%. Among them, six predictors remained significant in the final stepwise Cox model and generated similar predictive accuracy (AUC: 0.830; 95% CI: 0.775-0.885). Besides the well-established predictors (e.g., gestational age, 5 min Apgar scores, and multiplicity), this study highlights the predictive value of the maximum FiO2. It emphasizes the significance of the early use of additional doses of surfactant and umbilical vein catheterization (UVC) in reducing mortality. CONCLUSIONS We identified six significant predictors for pre-discharge mortality. The findings highlighted the modifiable factors (FiO2, surfactant, and UVC) as crucial neonatal factors for predicting mortality risk in EPIs or ELBWIs, and offer valuable guidance for early clinical management.
Collapse
Affiliation(s)
- Zhenyuan Dai
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| | - Xiaobing Zhong
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| | - Qian Chen
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| | - Yuming Chen
- Department of Epidemiology, School of Public Health, Sun Yat-sen University, Guangzhou 510080, China;
| | - Sinian Pan
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| | - Huiqing Ye
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| | - Xinyi Tang
- Department of Pediatrics, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou 510630, China; (Z.D.); (X.Z.); (Q.C.); (S.P.); (H.Y.)
| |
Collapse
|
3
|
Buttera M, Corso L, Casadei L, Valenza C, Sforza F, Candia F, Miselli F, Baraldi C, Lugli L, Berardi A, Iughetti L. Can a Shorter Dwell Time Reduce Infective Complications Associated with the Use of Umbilical Catheters? Antibiotics (Basel) 2024; 13:988. [PMID: 39452254 PMCID: PMC11504672 DOI: 10.3390/antibiotics13100988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Revised: 10/03/2024] [Accepted: 10/15/2024] [Indexed: 10/26/2024] Open
Abstract
BACKGROUND Umbilical venous catheters (UVCs) are the standard of care in neonatal intensive care units (NICUs) to administer fluids, parenteral nutrition and medications, although complications may occur, including central line-associated blood stream infections (CLABSIs). However, the dwell time to reduce CLABSI risk remains an open issue. METHODS We performed a single-center retrospective study of newborns hospitalized in the Modena NICU with at least one UVC inserted over a 6-year period (period 1: January 2011-December 2013; period 2: January 2019-December 2021). We selected a non-consecutive 6-year period to emphasize the differences in UVC management practices that have occurred over time in our NICU. The UVC dwell time and catheter-related complications during the first 4 weeks of life were examined. RESULTS The UVC dwell time was shorter in period 2 (median 4 days vs. 5 days, p < 0.00001). Between the two periods, the incidence of CLABSIs remained unchanged (p = 0.5425). However, in period 2, there was an increased need for peripherally inserted central catheters (PICCs) after UVC removal, with a rise in PICC infections after UVC removal (p = 0.0239). CONCLUSIONS In our NICU, shortening UVC dwell time from 5 to 4 days did not decrease the UVC-related complications. Instead, the earlier removal of UVCs led to a higher number of PICCs inserted, possibly increasing the overall infectious risk.
Collapse
Affiliation(s)
- Martina Buttera
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
| | - Lucia Corso
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
| | - Leonardo Casadei
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
| | - Cinzia Valenza
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
| | - Francesca Sforza
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
| | - Francesco Candia
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
- Pediatrics Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Francesca Miselli
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Cecilia Baraldi
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Licia Lugli
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Alberto Berardi
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Lorenzo Iughetti
- University of Modena and Reggio Emilia, Via del Pozzo 71, 41224 Modena, Italy
- Pediatrics Unit, University Hospital of Modena, 41224 Modena, Italy
| |
Collapse
|
4
|
Meyer S, Hess S, Poryo M, Papan C, Simon A, Welcker S, Ehrlich A, Ruckes C. Study draft: "UVC-You Will See" study: longer vs. shorter umbilical venous catheter (UVC) dwell time (6-10 vs. 1-5 days) in very premature infants with birth weight < 1250 g and/or gestational age < 30 weeks. Wien Med Wochenschr 2024; 174:217-224. [PMID: 38869762 PMCID: PMC11347460 DOI: 10.1007/s10354-024-01047-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 05/13/2024] [Indexed: 06/14/2024]
Abstract
BACKGROUND Umbilical venous catheters (UVCs) are often used in preterm infants. Their use is associated with complications (infections, clot formation, organ injury). Very preterm infants with acquired bloodstream infection are at a higher risk for death and important morbidities (e.g., adverse neurodevelopmental outcomes). It is standard clinical practice to remove UVCs in the first days of life. Replacement of intravenous access is often performed using percutaneously inserted central catheters (PICCs). It is unclear whether serial central line use affects the rates of catheter-related complications. METHODS A multicenter randomized controlled trial (random group assignment) was performed in 562 very premature (gestational age < 30 weeks) and/or very low birth weight infants (< 1250 g) requiring an UVC for administration of parenteral nutrition and/or drugs. Group allocation was random. HYPOTHESIS A UVC dwell time of 6-10 days (281 infants) is not associated with an increased rate of central venous catheter (UVC, PICC)-related complications compared to 1-5 days (281 infants), and a longer UVC dwell time will significantly reduce the number of painful, invasive procedures associated with the need for vascular access as well as radiation exposure, use of antibiotics, and medical costs. PRIMARY OUTCOME PARAMETER The number of catheter-related bloodstream infections and/or catheter-related thromboses and/or catheter-associated organ injuries related to the use of UVC/PICC was the primary outcome. CONCLUSION Extending the UVC dwell time may significantly reduce the number of painful invasive procedures, with the potential to positively impact not only long-term pain perception but also important social competencies (attention, learning, and behavior). Thus, the "UVC-You Will See" study has the potential to substantially change current neonatal intensive care practice.
Collapse
Affiliation(s)
- Sascha Meyer
- Department of Pediatrics and Neonatology, University Hospital Saarland, Homburg, Germany.
| | - Steffi Hess
- Kinder- und Jugendmedizin, Klinikum Saarbrücken Winterberg, Saarbrücken, Germany
| | - Martin Poryo
- Department of Pediatric Cardiology, Saarland University Medical Center, Homburg, Germany
| | - Cihan Papan
- Institute for Hygiene and Public Health, University Hospital Bonn, Bonn, Germany
| | - Arne Simon
- Department of Pediatric Hematology and Oncology, and Infectious Diseases, Saarland University Medical Center, Homburg, Germany
| | - Silvia Welcker
- Franz-Lust Klinik für Kinder und Jugendliche, Städtisches Klinikum Karlsruhe, Moltkestraße 90, 76135, Karlsruhe, Germany
| | - Anne Ehrlich
- Interdisziplinäres Zentrum für Klinische Studien (IZKS), Mainz, Germany
| | - Christian Ruckes
- Interdisziplinäres Zentrum für Klinische Studien (IZKS), Mainz, Germany
| |
Collapse
|
5
|
Sobczak A, Kowalik A, Homa M, Turalska P, Kwinta P. Changes in umbilical catheters' microstructure in vivo: A prospective study. J Vasc Access 2024; 25:158-164. [PMID: 35674147 DOI: 10.1177/11297298221100441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Umbilical vessels present after birth allow a unique central access for both venous and arterial catheterization, yet the catheterization complications can be misdiagnosed as the complications of prematurity per se. METHODS A prospective observational study of 41 used polyurethane umbilical catheters, both venous and arterial was conducted in a tertiary neonatal intensive care unit. The study consisted of bedside ultrasound imaging and post-removal microbiological and microstructural analysis to assess the in vivo catheters' changes and their clinical significance. RESULTS The study has shown that catheters' surface thrombosis and bacterial colonization happen more often within umbilical venous than within arterial catheters (31% vs 8% in both cases) and are inversely proportional to the patient's gestational age (thrombosis: Me: 28 weeks vs no thrombosis: 32 weeks; p = 0.05, bacterial colonization: 27 weeks vs no colonization: 30 weeks; p = 0.013), respectively. The clots formed near the catheter's tip are correlated with catheter's bacterial colonization. Chemical analysis with energy dispersive spectroscopy showed a higher calcium composition in used catheters (19.89% vs 0%, p = 0.016) and structure analysis in the scanning electron microscopy proved that within hours catheters become covered with an external coating of a constant thickness, not affected by the catheterization time. CONCLUSION The following observations give a better insight to the complex in vivo interactions and call for a more intense bedside-monitoring of the indwelling devices.
Collapse
Affiliation(s)
- Alina Sobczak
- Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| | - Aleksandra Kowalik
- Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| | - Marta Homa
- Center for High Temperature Studies, Foundry Research Institute, Kraków, Poland
| | - Patrycja Turalska
- Center for High Temperature Studies, Foundry Research Institute, Kraków, Poland
| | - Przemko Kwinta
- Department of Pediatrics, Jagiellonian University Medical College, Kraków, Poland
| |
Collapse
|
6
|
Salonen S, Tammela O, Koivisto AM, Korhonen P. Umbilically and Peripherally Inserted Thin Central Venous Catheters Have Similar Risks of Complications in Very Low-Birth-Weight Infants. Clin Pediatr (Phila) 2023; 62:1361-1368. [PMID: 36942607 PMCID: PMC10548765 DOI: 10.1177/00099228231161299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
Catheter complications can be life-threatening in very low-birth-weight (VLBW) infants. We retrospectively evaluated non-elective removals of the first thin (1-2F) umbilical vein catheters (tUVCs (n = 92)) and peripherally inserted central venous catheters (PICCs (n = 103)) among 195 VLBW infants. Catheters were removed non-electively in 78 infants (40%), typically due to suspected infection (n = 42) or catheter dislocation (n = 30). Infants with complications had lower birth weights and gestational ages than others. The frequencies and causes of catheter removal were similar in the tUVC and PICC groups. Thirty-one infants had true catheter infections. The number of infections/1000 catheter days was higher in the tUVC group than in the PICC group. In a multivariable analysis, gestational age was associated with catheter infection, but catheter type was not. The odds of catheter complications decreased with increasing gestational age, but no clear association with thin catheter type was found.
Collapse
Affiliation(s)
- S. Salonen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - O. Tammela
- Tampere Center for Child Adolescent and Maternal Health Research, Faculty of Medicine and Health Technology, Tampere University Hospital, Tampere University, Tampere, Finland
| | - A. M. Koivisto
- Faculties of Social Science and Health Science, Tampere University, Tampere, Finland
| | - P. Korhonen
- Tampere Center for Child Adolescent and Maternal Health Research, Faculty of Medicine and Health Technology, Tampere University Hospital, Tampere University, Tampere, Finland
| |
Collapse
|
7
|
Muhd Helmi MA, Lai NM, Van Rostenberghe H, Ayub I, Mading E. Antiseptic solutions for skin preparation during central catheter insertion in neonates. Cochrane Database Syst Rev 2023; 5:CD013841. [PMID: 37142550 PMCID: PMC10158577 DOI: 10.1002/14651858.cd013841.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
BACKGROUND Central venous catheters (CVC) are associated with potentially dangerous complications such as thromboses, pericardial effusions, extravasation, and infections in neonates. Indwelling catheters are amongst the main risk factors for nosocomial infections. The use of skin antiseptics during the preparation for central catheter insertion may prevent catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI). However, it is still not clear which antiseptic solution is the best to prevent infection with minimal side effects. OBJECTIVES To systematically evaluate the safety and efficacy of different antiseptic solutions in preventing CRBSI and other related outcomes in neonates with CVC. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, and trial registries up to 22 April 2022. We checked reference lists of included trials and systematic reviews that related to the intervention or population examined in this Cochrane Review. SELECTION CRITERIA: Randomised controlled trials (RCTs) or cluster-RCTs were eligible for inclusion in this review if they were performed in the neonatal intensive care unit (NICU), and were comparing any antiseptic solution (single or in combination) against any other type of antiseptic solution or no antiseptic solution or placebo in preparation for central catheter insertion. We excluded cross-over trials and quasi-RCTs. DATA COLLECTION AND ANALYSIS We used the standard methods from Cochrane Neonatal. We used the GRADE approach to assess the certainty of the evidence. MAIN RESULTS We included three trials that had two different comparisons: 2% chlorhexidine in 70% isopropyl alcohol (CHG-IPA) versus 10% povidone-iodine (PI) (two trials); and CHG-IPA versus 2% chlorhexidine in aqueous solution (CHG-A) (one trial). A total of 466 neonates from level III NICUs were evaluated. All included trials were at high risk of bias. The certainty of the evidence for the primary and some important secondary outcomes ranged from very low to moderate. There were no included trials that compared antiseptic skin solutions with no antiseptic solution or placebo. CHG-IPA versus 10% PI Compared to PI, CHG-IPA may result in little to no difference in CRBSI (risk ratio (RR) 1.32, 95% confidence interval (CI) 0.53 to 3.25; risk difference (RD) 0.01, 95% CI -0.03 to 0.06; 352 infants, 2 trials, low-certainty evidence) and all-cause mortality (RR 0.88, 95% CI 0.46 to 1.68; RD -0.01, 95% CI -0.08 to 0.06; 304 infants, 1 trial, low-certainty evidence). The evidence is very uncertain about the effect of CHG-IPA on CLABSI (RR 1.00, 95% CI 0.07 to 15.08; RD 0.00, 95% CI -0.11 to 0.11; 48 infants, 1 trial; very low-certainty evidence) and chemical burns (RR 1.04, 95% CI 0.24 to 4.48; RD 0.00, 95% CI -0.03 to 0.03; 352 infants, 2 trials, very low-certainty evidence), compared to PI. Based on a single trial, infants receiving CHG-IPA appeared less likely to develop thyroid dysfunction compared to PI (RR 0.05, 95% CI 0.00 to 0.85; RD -0.06, 95% CI -0.10 to -0.02; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 10 to 50; 304 infants). Neither of the two included trials assessed the outcome of premature central line removal or the proportion of infants or catheters with exit-site infection. CHG-IPA versus CHG-A The evidence suggests CHG-IPA may result in little to no difference in the rate of proven CRBSI when applied on the skin of neonates prior to central line insertion (RR 0.80, 95% CI 0.34 to 1.87; RD -0.05, 95% CI -0.22 to 0.13; 106 infants, 1 trial, low-certainty evidence) and CLABSI (RR 1.14, 95% CI 0.34 to 3.84; RD 0.02, 95% CI -0.12 to 0.15; 106 infants, 1 trial, low-certainty evidence), compared to CHG-A. Compared to CHG-A, CHG-IPA probably results in little to no difference in premature catheter removal (RR 0.91, 95% CI 0.26 to 3.19; RD -0.01, 95% CI -0.15 to 0.13; 106 infants, 1 trial, moderate-certainty evidence) and chemical burns (RR 0.98, 95% CI 0.47 to 2.03; RD -0.01, 95% CI -0.20 to 0.18; 114 infants, 1 trial, moderate-certainty evidence). No trial assessed the outcome of all-cause mortality and the proportion of infants or catheters with exit-site infection. AUTHORS' CONCLUSIONS Based on current evidence, compared to PI, CHG-IPA may result in little to no difference in CRBSI and mortality. The evidence is very uncertain about the effect of CHG-IPA on CLABSI and chemical burns. One trial showed a statistically significant increase in thyroid dysfunction with the use of PI compared to CHG-IPA. The evidence suggests CHG-IPA may result in little to no difference in the rate of proven CRBSI and CLABSI when applied on the skin of neonates prior to central line insertion. Compared to CHG-A, CHG-IPA probably results in little to no difference in chemical burns and premature catheter removal. Further trials that compare different antiseptic solutions are required, especially in low- and middle-income countries, before stronger conclusions can be made.
Collapse
Affiliation(s)
- Muhd Alwi Muhd Helmi
- Department of Paediatrics, Kulliyyah of Medicine, International Islamic University Malaysia, Kuantan, Malaysia
| | - Nai Ming Lai
- School of Medicine, Taylor's University, Subang Jaya, Malaysia
| | - Hans Van Rostenberghe
- Department of Paediatrics, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Malaysia
| | - Izzudeen Ayub
- Department of Paediatrics, Hospital Pengajar Universiti Sultan Zainal Abidin, Kuala Terengganu, Malaysia
| | - Emie Mading
- Faculty of Medicine and Health Sciences, University Malaysia Sabah (UMS), Sabah, Malaysia
| |
Collapse
|
8
|
Kim MJ, Yoo SY, Jeon TY, Kim JH, Kim YJ. Imaging of Umbilical Venous Catheter-Related Hepatic Complications in Neonates. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2023; 84:586-595. [PMID: 37324991 PMCID: PMC10265250 DOI: 10.3348/jksr.2022.0056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
An umbilical venous catheter (UVC) is commonly placed for central venous access in preterm or critically ill full-term neonates to provide total parenteral nutrition (TPN) and medication. However, UVCs can result in complications, including infection, portal vein thrombosis, and hepatic tissue injury. The inadvertent administration of hypertonic fluid through a malpositioned UVC can also cause hepatic parenchymal damage with mass-like fluid collection that simulates a tumorous condition during imaging. Ultrasonography and radiographic examinations play an essential role in detecting UVC-related complications. This pictorial essay aims to present the imaging findings of UVC-related hepatic complications in neonates.
Collapse
|
9
|
Corso L, Buttera M, Candia F, Sforza F, Rossi K, Lugli L, Miselli F, Bedetti L, Baraldi C, Lucaccioni L, Iughetti L, Berardi A. Infectious Risks Related to Umbilical Venous Catheter Dwell Time and Its Replacement in Newborns: A Narrative Review of Current Evidence. Life (Basel) 2022; 13:123. [PMID: 36676072 PMCID: PMC9863057 DOI: 10.3390/life13010123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/27/2022] [Accepted: 12/28/2022] [Indexed: 01/03/2023] Open
Abstract
The use of umbilical venous catheters (UVCs) has become the standard of care in the neonatal intensive care unit (NICU) to administer fluids, medications and parenteral nutrition. However, it is well known that UVCs can lead to some serious complications, both mechanical and infective, including CLABSI (Central Line-Associated Bloodstream Infections). Most authors recommend removing UVC within a maximum of 14 days from its placement. However, the last Infusion Therapy Standards of Practice (INS) guidelines recommends limiting the UVC dwell time to 7 to 10 days, to reduce risks of infectious and thrombotic complications. These guidelines also suggest as an infection prevention strategy to remove UVC after 4 days, followed by the insertion of a PICC if a central line is still needed. Nevertheless, the maximum UVC dwell time to reduce the risk of CLABSI is still controversial, as well as the time of its replacement with a PICC. In this study we reviewed a total of 177 articles, found by using the PubMed database with the following search strings: "UVC AND neonates", "(neonate* OR newborn*) AND (UVC OR central catheter*) AND (infection*)". We also analyze the INS guidelines to provide the reader an updated overview on this topic. The purpose of this review is to give updated information on CVCs infectious risks by examining the literature in this field. These data could help clinicians in deciding the best time to remove or to replace the UVC with a PICC, to reduce CLABSIs risk. Despite the lack of strong evidence, the risk of CLABSI seems to be minimized when UVC is removed/replaced within 7 days from insertion and this indication is emerging from more recent and larger studies.
Collapse
Affiliation(s)
- Lucia Corso
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
| | - Martina Buttera
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
| | - Francesco Candia
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
| | - Francesca Sforza
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
| | - Katia Rossi
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Licia Lugli
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Francesca Miselli
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Luca Bedetti
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Cecilia Baraldi
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Laura Lucaccioni
- Pediatrics Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Lorenzo Iughetti
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
- Pediatrics Unit, University Hospital of Modena, 41224 Modena, Italy
| | - Alberto Berardi
- School of Pediatrics Residency, University of Modena and Reggio Emilia, 41224 Modena, Italy
- Neonatal Intensive Care Unit, University Hospital of Modena, 41224 Modena, Italy
| |
Collapse
|
10
|
Rabie D, Mostafa MF, Abdel Halim RM, Ezzat OA. Central line-associated bloodstream infection (CLABSI) with three different vascular access in neonatal intensive care unit. EGYPTIAN PEDIATRIC ASSOCIATION GAZETTE 2022. [DOI: 10.1186/s43054-022-00108-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Central venous catheters (CVCs) are a mandatory aspect in the neonatal intensive care units. Unfortunately, bloodstream infection is a frequent complication of CVCs. A needleless connector is attached to the end of CVC to allow infusion of fluids. We aimed to assess the effect of needleless connectors on central line-associated blood stream infection, and to assess rate of occurrence of bloodstream infection with the use of three different types of venous access in neonates.
Methods
This study is a prospective, randomized, comparative study which was held at the Neonatal Intensive Care, Faculty of Medicine, Ain Shams University. The study recruited 120 neonates who were categorized into three groups according to the type of inserted CVC: group A with umbilical venous catheter, group B with peripherally inserted central catheter, and group C with non-tunneled central venous catheter, and each group was further subdivided into two groups according to the use of needleless connector. Criteria of central line-associated bloodstream infection (CLABSI) and central line-related bloodstream infection (CLRBSI) were applied.
Results
The study included 120 neonates, a multivariable logistic regression analysis was held for two predictors (type of CVC and use of needleless connector) of CLABSI/CLRBSI, it revealed that the use of needleless connector was associated with significant lower incidence of CLABSI/CLRBSI (P value < 0.05, adjusted odds ratio [aOR] = 0.303), the use of peripheral inserted central catheter (PICC) was also associated with the lowest incidence of CLABSI/CLRBSI (P value = 0.015, aOR = 0.284). Another multivariable logistic regression analysis was done for four predictors (type of CVC, use of needleless connector, gestational age, and catheter dwell time) which revealed that the gestational age (P value = 0.001, aOR = 0.691) and catheter dwell time (P value = 0.004, aOR = 1.313) were the only independent predictors for the occurrence of CLABSI/CLRBSI.
Conclusion
The use of needleless connector can lower the incidence of CLABSI/CLRBSI, PICC line was associated with the lowest incidence of CLABSI/CLRBSI among the three types of CVCs. Low gestational age and long catheter dwell time were found to be the main risk factors for increasing the incidence of CLABSI/CLRBSI.
Collapse
|
11
|
van Rens MFPT, Bayoumi MAA, van de Hoogen A, Francia ALV, Cabanillas IJ, van Loon FHJ, Spencer TR. The ABBA project (Assess Better Before Access): A retrospective cohort study of neonatal intravascular device outcomes. Front Pediatr 2022; 10:980725. [PMID: 36405839 PMCID: PMC9670536 DOI: 10.3389/fped.2022.980725] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/30/2022] [Indexed: 11/06/2022] Open
Abstract
Background Venous access devices (VADs) play a vital role within the neonatal intensive care unit. However, there are significant risks associated with the use of VADs, with complications such as infection, thrombosis, device occlusion, and infiltration/extravasation frequently contributing to device-related failures and increasing the risk of significant patient harm or injury. This study aimed to explore the relationships between risk factors and different venous access device complications in the neonatal setting, and then use that evidence to develop an algorithm based on observational data. Methods This is a retrospective, single-center cohort study that was conducted in a large 112-bed neonatal intensive care unit in Qatar. We examined venous access device data from January 2016 to December 2018 for all term and preterm neonates. Descriptive statistics were used to summarize the outcomes, which included a mean and its standard deviation or median and an interquartile range for continuous variables regarding normal distribution, and absolute numbers with percentages for discrete variables. Results The authors recorded a total of 23,858 VADs inserted during the study period. Of these, 21,313 (89%) were peripheral intravenous catheters, 689 (3%) were extended dwell-peripheral intravenous catheters, 1,335 (6%) were epicutaneo-caval catheters, and 521 (2%) were umbilical venous catheters. In total, 51,179 catheter days were registered, with 2.17 catheter days reported per patient. Peripheral device dwell times were significantly shorter when compared with central venous catheter devices (P < 0.001), with mean dwell times of 22 days ± 23 h and 236 days ± 183 h, respectively. After insertion, a complication occurred in 11,177 (51%) of peripheral VADs and 221 (12%) of central VADs. The type of device inserted [P < 0.001, hazard ratio (HR) = 0.52, 95% confidence interval (CI): 0.50-0.54], reason/indication for intravenous therapy (P < 0.001, HR = 0.85, 95% CI: 0.82-0.87), and the side of insertion of the device (P < 0.001, HR = 1.25, 95% CI: 1.24-1.27) had a significant relationship with outcomes. Conclusions Four subgroups of VADs were identified (peripheral intravenous catheters, extended dwell-peripheral intravenous devices, epicutaneo-caval catheters, and umbilical venous catheters) with outcome-related differences. Central venous access devices (epicutaneo-caval catheters and umbilical venous catheters) had lower complications compared with peripheral VADs. Proper venous access device selection, early insertion, and early removal approaches remain crucial to preventing venous access device complications. Peripheral intravenous devices should be used carefully and closely watched for early detection of complications.
Collapse
Affiliation(s)
- Matheus F. P. T. van Rens
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Mohammad A. A. Bayoumi
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Agnes van de Hoogen
- Department of Neonatology, Wilhelmina Children's Hospital, University Medical Centre of Utrecht, Utrecht, Netherlands
| | - Airene L. V. Francia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Irian J. Cabanillas
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Fredericus H. J. van Loon
- Department of Science and Technology in Perioperative Nursing, Fontys University of Applied Sciences, Eindhoven, Netherlands
| | - Timothy R. Spencer
- Nursing Department, Global Vascular Access, LLC, Scottsdale, AZ, United States
| |
Collapse
|
12
|
Riskin A, Iofe A, Zidan D, Shoris I, Toropine A, Zoabi-Safadi R, Bader D, Gover A. An Observational Study on the Use of Peripheral Intravenous Lines vs. Central Lines in a Neonatal Intensive Care Unit. CHILDREN 2022; 9:children9091413. [PMID: 36138722 PMCID: PMC9498162 DOI: 10.3390/children9091413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/01/2022] [Accepted: 09/03/2022] [Indexed: 11/21/2022]
Abstract
Background and Objectives: There is a debate regarding the preferred intravenous (IV) access for newborns. Our aim was to study practices regarding the choice of vascular access and outcomes. Methods: A seven-month prospective observational study on IV lines used in all newborns admitted to Bnai Zion Medical Center’s neonatal intensive care unit (NICU). Results: Of 120 infants followed, 94 required IV lines. Infants born at ≤32 weeks gestation, or with a head circumference ≤29 cm were more likely to require two or more IV lines or a central line for the administration of parenteral nutrition or medications for longer periods. However, central lines (umbilical or peripherally inserted central catheters (PICC)) were not associated with better nutritional status at discharge based on weight z-scores. Only one complication was noted—a central line-associated bloodstream infection in a PICC. Conclusions: Our data suggest preferring central IV access for preterm infants born at ≤32 weeks or with a head circumference ≤29 cm. We encourage other NICUs to study their own data and draw their practice guidelines for preferred IV access (central vs. peripheral) upon admission to the NICU.
Collapse
Affiliation(s)
- Arieh Riskin
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
- Correspondence: ; Tel.: +972-48359063
| | - Adir Iofe
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| | - Donia Zidan
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| | - Irit Shoris
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
| | - Arina Toropine
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| | - Rasha Zoabi-Safadi
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| | - David Bader
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| | - Ayala Gover
- Department of Neonatology, Bnai Zion Medical Center, 47 Golomb Street, P.O. Box 4940, Haifa 31048, Israel
- Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
13
|
Merchaoui Z, Laudouar Q, Marais C, Morin L, Ghali N, Charbel R, Seeman N, Mokhtari M, Tissières P. Ultrasound guided percutaneous catheterization of the brachiocephalic vein by small caliber catheter: An alternative to epicutaneo-caval catheter in newborn and premature infants. J Vasc Access 2021; 24:487-491. [PMID: 34369212 DOI: 10.1177/11297298211034311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Umbilical Venous Catheter (UVC) and Epicutaneo-Caval Catheters (ECC) are reference catheters in the neonatal period. However, many factors such as the corpulence of neonates, poor venous capital, and anatomical variants can complicate ECC insertion or make it impossible. In newborns with failed ECC insertion, we developed an hybrid technique that combines the insertion of a long-lasting silicone or polyurethane small caliber catheter, usually used as a ECC in newborns, with the ease and speed of ultrasound guided puncture of the brachiocephalic vein (BCV). METHODS Three years retrospective single center experience of ultrasound guided BCV insertion of silicon or polyurethane small caliber central catheter in a tertiary neonatal intensive care in case of insertion fail of ECC. RESULTS Twenty-one echo guided BCV-ECC insertions were performed in 20 newborns. Median age was 16 days (range: 0-110 days), median weight was 1700 g (range: 605-4960 g) at insertion. In most cases, insertion was on the left side (17/21). No failures were noted. Only one attempt was necessary in all cases. Insertion time, when noted, was always of <45 min. The median duration of use of these catheters was 11 days (range 3-35 days). No complication was noted during insertion or catheter use, including catheter-related infections and thrombosis. CONCLUSION Echo guided percutaneous catheterization of the brachiocephalic vein with a long lasting silicone or polyurethane small caliber catheter is a safe alternative to the ECC if insertion has failed. However, it requires a mastery of ultrasound-guided insertion technique in term and premature neonates.
Collapse
Affiliation(s)
- Zied Merchaoui
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Quitterie Laudouar
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Clémence Marais
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Luc Morin
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Narjess Ghali
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Ramy Charbel
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Nada Seeman
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Mostafa Mokhtari
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| | - Pierre Tissières
- Pediatric and Neonatal Intensive Care Unit, Bicêtre Medical Centre, Paris Saclay University, AP HP, Le Kremlin Bicêtre, France
| |
Collapse
|
14
|
Skiba-Kurek I, Nowak P, Empel J, Tomczak M, Klepacka J, Sowa-Sierant I, Żak I, Pomierny B, Karczewska E. Evaluation of Biofilm Formation and Prevalence of Multidrug-Resistant Strains of Staphylococcus epidermidis Isolated from Neonates with Sepsis in Southern Poland. Pathogens 2021; 10:pathogens10070877. [PMID: 34358027 PMCID: PMC8308537 DOI: 10.3390/pathogens10070877] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 07/06/2021] [Accepted: 07/08/2021] [Indexed: 01/11/2023] Open
Abstract
Staphylococcus epidermidis strains play an important role in nosocomial infections, especially in the ones associated with biofilm formation on medical devices. The paper was aimed at analyzing the mechanisms of antibiotic resistance and confirming the biofilm-forming ability among S. epidermidis strains isolated from the blood of hospitalized newborns. Genetic analysis of resistance mechanism determinants included multiplex PCR detection of mecA, ermA, ermB, ermC, msrA, and mef genes. Biofilm analysis comprised phenotypic and genotypic methods including Christensen and Freeman methods and PCR detection of the icaADB gene complex. Among the tested S. epidermidis strains, 89% of the isolates were resistant to methicillin, 67%—to erythromycin, 53%—to clindamycin, 63%—to gentamicin, and 23%—to teicoplanin, while all the strains were susceptible to vancomycin and linezolid. The mecA gene was detected in 89% of the isolates, the ermC gene was the most common and present among 56% of the strains, while the msrA gene was observed in 11% isolates. Eighty-five percent of the strains were described as biofilm-positive by phenotypic methods and carried the icaADB gene cluster. Multidrug resistance and the biofilm-forming ability in most of the strains tested may contribute to antimicrobial therapy failure (p < 0.05).
Collapse
Affiliation(s)
- Iwona Skiba-Kurek
- Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Jagiellonian University Medical College, Medyczna 9 Street, 30-688 Krakow, Poland; (I.S.-K.); (P.N.)
| | - Paweł Nowak
- Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Jagiellonian University Medical College, Medyczna 9 Street, 30-688 Krakow, Poland; (I.S.-K.); (P.N.)
| | - Joanna Empel
- Department of Epidemiology and Clinical Microbiology, National Medicines Institute, Chełmska 30/34 Street, 00-725 Warsaw, Poland; (J.E.); (M.T.)
| | - Magdalena Tomczak
- Department of Epidemiology and Clinical Microbiology, National Medicines Institute, Chełmska 30/34 Street, 00-725 Warsaw, Poland; (J.E.); (M.T.)
| | - Joanna Klepacka
- Department of Clinical Microbiology, University Children’s Hospital of Krakow, Wielicka 256 Street, 30-663 Krakow, Poland; (J.K.); (I.S.-S.); (I.Ż.)
| | - Iwona Sowa-Sierant
- Department of Clinical Microbiology, University Children’s Hospital of Krakow, Wielicka 256 Street, 30-663 Krakow, Poland; (J.K.); (I.S.-S.); (I.Ż.)
| | - Iwona Żak
- Department of Clinical Microbiology, University Children’s Hospital of Krakow, Wielicka 256 Street, 30-663 Krakow, Poland; (J.K.); (I.S.-S.); (I.Ż.)
| | - Bartosz Pomierny
- Department of Toxicology, Faculty of Pharmacy, Jagiellonian University Medical College, Medyczna 9 Street, 30-688 Kraków, Poland;
| | - Elżbieta Karczewska
- Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Jagiellonian University Medical College, Medyczna 9 Street, 30-688 Krakow, Poland; (I.S.-K.); (P.N.)
- Correspondence: ; Tel.: +481-2620-5750; Fax: +481-2620-5758
| |
Collapse
|
15
|
Yeung CY. Complications of umbilical venous catheters in neonates: A safety reappraisal. Pediatr Neonatol 2020; 61:1-2. [PMID: 31953034 DOI: 10.1016/j.pedneo.2020.01.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Accepted: 12/22/2019] [Indexed: 12/25/2022] Open
Affiliation(s)
- Chun-Yan Yeung
- Division of Gastroenterology and Nutrition, Department of Pediatrics, MacKay Children's Hospital, No.92, Sec.2, Chung Shan North Road, 10449, Taipei, Taiwan; School of Medicine, MacKay Medical College, No.46, Sec. 3, Zhongzheng Rd., Sanzhi Dist., New Taipei City, 252, Taiwan.
| |
Collapse
|