1
|
Montero Peña C, Palma Maldonado FJ, Fidalgo López J, Casanova García C. [Use of clinical ultrasound in primary care: Markers in congestive heart failure]. Semergen 2024; 50:102383. [PMID: 39615270 DOI: 10.1016/j.semerg.2024.102383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 09/30/2024] [Accepted: 10/03/2024] [Indexed: 12/17/2024]
Abstract
The patient with heart failure (HF) is a frequent scenario in primary care consultations. The presence of subclinical congestion is a predictor of rehospitalization and adverse events in these patients. The assessment of congestion is complex due to the low sensitivity of classic symptoms and signs, which leads to underdiagnosis, delayed initiation of treatment and a greater likelihood of complications. The family doctor should be familiar with new techniques for congestion assessment, such as the study of venous congestion with ultrasound and pulmonary ultrasound. This makes it possible to know the existence of subclinical congestion in a more realistic way. Clinical ultrasound in the hands of the family doctor individualizes decongestive therapy in patients with HF in an accurate, fast and safe way.
Collapse
Affiliation(s)
- C Montero Peña
- MFyC, Centro de Salud Don Benito Oeste, Don Benito, Badajoz, España; Miembro del GT Ecografía SEMERGEN, España.
| | - F J Palma Maldonado
- MFyC, Centro de Salud Can Misses, Eivissa, Islas Baleares, España; Miembro del GT Ecografía SEMERGEN, España
| | - J Fidalgo López
- FEA de Urgencias, Hospital Universitario de Torrejón, Torrejón, Madrid, España; Miembro del GT Ecografía SEMERGEN, España
| | - C Casanova García
- Médico de familia, Centro de Salud Barrio del Pilar. Madrid, España; Miembro del GT Ecografía SEMERGEN, España
| |
Collapse
|
2
|
Landi I, Guerritore L, Iannaccone A, Ricotti A, Rola P, Garrone M. Assessment of venous congestion with venous excess ultrasound score in the prognosis of acute heart failure in the emergency department: a prospective study. EUROPEAN HEART JOURNAL OPEN 2024; 4:oeae050. [PMID: 39234262 PMCID: PMC11373564 DOI: 10.1093/ehjopen/oeae050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/21/2024] [Accepted: 06/14/2024] [Indexed: 09/06/2024]
Abstract
Aims In acute decompensated heart failure (HF), systemic venous congestion contributes to patients' symptoms and hospital admissions. The purpose of our study is to determine if venous congestion, examined using the venous excess ultrasound (VExUS) score, predicts HF-related hospitalization and mortality in patients admitted to the emergency department (ED) with acute decompensated HF. Methods and results Fifty patients admitted for acute HF in ED underwent ultrasound (US) assessment according to the VExUS score within the first 24 and 72 h. All patients were followed up with a telephone call at 30 and 60 days after hospital discharge. On admission, 56% had a VExUS score of 3. After 72 h, 32% had no more signs of congestion at the Doppler VExUS examination (inferior vena cava < 2 cm, VExUS score of 0); a similar percentage still exhibited a VExUS score of 3 despite therapy. Eighty per cent of patients were hospitalized after admission to the ED, while six (15%) died in-hospital; all exhibited a first-assessment VExUS score of 3. No patient with a VExUS score < 3 died during the study. During short-term follow-up, 18 patients were readmitted to the ED for acute decompensated HF. Ninety-four per cent of the readmitted patients had a VExUS score of 3 at the Doppler assessment at the first ED admission. Conclusion Severe venous congestion, defined as a VExUS score of 3 at the initial assessment of patients with acute decompensated HF, predicts inpatient mortality, HF-related death, and early readmission.
Collapse
Affiliation(s)
- Irene Landi
- Dipartimento di Medicina Traslazionale, Università del Piemonte Orientale, Novara, Italia
| | - Ludovica Guerritore
- Medicina Chirurgia d'accettazione e d'urgenza, Azienda Ospedaliera Ordine Mauriziano, Via Magellano 1, 10128 Torino, Italia
| | - Andrea Iannaccone
- Medicina Interna e Unità di Terapia Semi Intensiva internistica, Azienda Ospedaliera Ordine Mauriziano, Via Magellano 1, 10128 Torino, Italia
| | - Andrea Ricotti
- Clinical Trial Unit, Azienda Ospedaliera Ordine Mauriziano, Via Magellano 1, 10128 Torino, Italia
| | - Philippe Rola
- Division of Intensive Care, Santa Cabrini Hospital, Montreal, QC, Canada
| | - Marco Garrone
- Medicina Chirurgia d'accettazione e d'urgenza, Azienda Ospedaliera Ordine Mauriziano, Via Magellano 1, 10128 Torino, Italia
| |
Collapse
|
3
|
Dimopoulos S, Antonopoulos M. Portal vein pulsatility: An important sonographic tool assessment of systemic congestion for critical ill patients. World J Cardiol 2024; 16:221-225. [PMID: 38817642 PMCID: PMC11135329 DOI: 10.4330/wjc.v16.i5.221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 02/19/2024] [Accepted: 04/01/2024] [Indexed: 05/23/2024] Open
Abstract
In this editorial we comment on the article by Kuwahara et al, published in the recent issue of the World Journal of Cardiology. In this interesting paper, the authors showed a correlation between portal vein pulsatility ratio, examined by bedside ultrasonography, and prognosis of hospitalized patients with acute heart failure. Systemic congestion is being notoriously underdetected in the acutely ill population with conventional methods like clinical examination, biomarkers, central venous pressure estimation and X-rays. However, congestion should be a key therapeutic target due to its deleterious effects to end organ function and subsequently patient prognosis. Doppler flow assessment of the abdominal veins is gaining popularity worldwide, as a valuable tool in estimating comprehensively congestion and giving a further insight into hemodynamics and patient management.
Collapse
Affiliation(s)
- Stavros Dimopoulos
- Cardiac Surgery ICU, Onassis Cardiac Surgery Center, Kallithea 17674, Greece.
| | | |
Collapse
|
4
|
Ke DYJ, Tso M, Johri AM. The Application of Point of Care Ultrasound to Screen for Pulmonary Hypertension: A Narrative Review. POCUS JOURNAL 2024; 9:109-116. [PMID: 38681162 PMCID: PMC11044931 DOI: 10.24908/pocus.v9i1.17494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
BACKGROUND Pulmonary Hypertension (PH) is a condition with several cardiopulmonary etiologies that has the potential of progressing to right heart failure without proper intervention. After a history, physical exam, and investigations, cases of suspected PH typically undergo imaging via a transthoracic echocardiogram (TTE). This is a resource-intensive procedure that is less accessible in remote communities. However, point of care ultrasound (POCUS), a portable ultrasound administered at the bedside, has potential to aid in the diagnostic process of PH. METHODS The MEDLINE, Embase, and CENTRAL databases were searched to screen the intersection of POCUS and PH. Studies involved adult patients, and only English articles were accepted. Reviews, case reports, unfinished research, and conference abstracts were excluded. Our aim was to identify primary studies that correlated POCUS scan results and additional clinical findings related to PH. RESULTS Nine studies were included after our search. In these studies, POCUS was effective in identifying dilatation of inferior vena cava (IVC); internal jugular vein (IJV); and hepatic, portal, and intrarenal veins in patients with PH. The presence of pericardial effusion, pleural effusion, or b-lines on POCUS are also associated with PH. CONCLUSIONS This review suggests important potential for the use of POCUS in the initial screening of PH. IVC and basic cardiopulmonary POCUS exams are key for PH screening in patients with dyspnea. Right-heart dilatation can be visualized, and peripheral veins may be scanned based on clinical suspicion. POCUS offers screening as an extension of a physical exam, with direct visualization of cardiac morphology. However, more studies are required to develop a statistically validated POCUS exam for PH diagnosis. More studies should also be conducted at the primary-care level to evaluate the value of screening using POCUS for PH in less-differentiated patients.
Collapse
Affiliation(s)
| | - Melissa Tso
- Queen's University School of MedicineKingston, ONCanada
- Kingston Health Sciences CentreKingston, ONCanada
| | - Amer M Johri
- Queen's University School of MedicineKingston, ONCanada
- Kingston Health Sciences CentreKingston, ONCanada
| |
Collapse
|
5
|
Xu P, Nasr B, Li L, Huang W, Liu W, Wang X. Correlation analysis between lung ultrasound scores and pulmonary arterial systolic pressure in patients with acute heart failure admitted to the emergency intensive care unit. JOURNAL OF INTENSIVE MEDICINE 2024; 4:125-132. [PMID: 38263970 PMCID: PMC10800768 DOI: 10.1016/j.jointm.2023.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/01/2023] [Accepted: 08/18/2023] [Indexed: 01/25/2024]
Abstract
BACKGROUND No convenient, inexpensive, and non-invasive screening tools exist to identify pulmonary hypertension (PH) - left heart disease (LHD) patients during the early stages of the disease course. This study investigated whether different methods of lung ultrasound (LUS) could be used for the initial investigation of PH-LHD. METHODS This was a single-center prospective observational study which was performed in the Zigong Fourth People's Hospital. We consecutively enrolled patients with heart failure (HF) admitted to the emergency intensive care unit from January 2018 to May 2020. Transthoracic echocardiography and LUS were performed within 24 h before discharge. We used the Spearman coefficient for correlation analysis between ultrasound scores and pulmonary arterial systolic pressure (PASP). Bland-Altman plots were generated to inspect possible bias, and receiver operating characteristic (ROC) curves were calculated to assess the relationship between ultrasound scores and an intermediate and high echocardiographic probability of PH-LHD. RESULTS Seventy-one patients were enrolled in this study, with an overall median age of 79 (interquartile range: 71.5-84.0) years. Among the 71 patients, 36 (50.7%) cases were male, and 26 (36.6%) had an intermediate and high echocardiographic probability of PH. All four LUS scores in patients with an intermediate and high probability of PH were significantly higher than in patients with a low probability of PH (P <0.05). The correlation coefficient (r) between different LUS scoring methods and PASP was moderate for the 6-zone (r=0.455, P <0.001), 8-zone (r=0.385, P=0.001), 12-zone (r=0.587, P <0.001), and 28-zone (r=0.535, P <0.001) methods. In Bland-Altman plots, each of the four LUS scoring methods had a good agreement with PASP (P <0.001). The 8-zone and 12-zone methods showed moderately accurate discriminative values in differentiating patients with an intermediate and high echocardiographic probability of PH (P <0.05). CONCLUSIONS LUS is a readily available, inexpensive, and risk-free method that moderately correlates with PASP. LUS is a potential screening tool used for the initial investigation of PH-LHD, especially in emergencies or critical care settings.
Collapse
Affiliation(s)
- Ping Xu
- Emergency Department, Zigong Fourth People's Hospital, Zigong, China
- Institute of Medical Big Data, Zigong Academy of Artificial Intelligence and Big Data for Medical Science, Zigong, China
- Artificial Intelligence Key Laboratory of Sichuan Province, Zigong, China
| | - Basma Nasr
- Department of Cardiology, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Liang Li
- Emergency Department, Zigong Fourth People's Hospital, Zigong, China
| | - Wenbin Huang
- Emergency Department, Zigong Fourth People's Hospital, Zigong, China
| | - Wei Liu
- Emergency Department, Zigong Fourth People's Hospital, Zigong, China
- Institute of Medical Big Data, Zigong Academy of Artificial Intelligence and Big Data for Medical Science, Zigong, China
| | - Xuelian Wang
- Emergency Department, Zigong Fourth People's Hospital, Zigong, China
| |
Collapse
|
6
|
Gupta B, Ahluwalia P, Gupta A, Ranjan N, Kakkar K, Aneja P. Utility of VExUS score in the peri-operative care unit, intensive care unit, and emergency setting - A systematic review. Indian J Anaesth 2023; 67:S218-S226. [PMID: 38187971 PMCID: PMC10768914 DOI: 10.4103/ija.ija_475_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 09/08/2023] [Accepted: 10/31/2023] [Indexed: 01/09/2024] Open
Abstract
Background and Aims The venous excess ultrasound (VExUS) score presents a prospect of valuable clinical utility. The study aimed to systematically review the effectiveness of the VExUS score in detecting venous congestion across emergency, critical care, and peri-operative contexts; assessing its utility in improved patient outcomes; and exploring its relationship with established parameters. Methods This systematic review was registered in the International Prospective Register of Systematic Reviews (CRD42023421034). A comprehensive literature search, employing pre-defined search terms related to the VExUS score in diverse clinical contexts, was conducted on articles published between 2000 and 15 May 2023 across databases- PubMed, PubMed Central, Cochrane, Scopus, Elsevier Clinical Key, and Google Scholar. Bias risk assessment was carried out using the Risk of Bias in Non-Randomised Studies tool. Given the significant heterogeneity across studies concerning participants, interventions, outcomes, and study designs, data pooling for a meaningful meta-analysis was not feasible. Results The review included 15 articles comprising observational studies, case series, and case reports. Most patients exhibited moderate-to-severe venous congestion based on their baseline VExUS scores. Higher VExUS scores correlated with a greater risk of acute kidney injury (AKI) in post-operative patients. The VExUS score strongly correlated with central venous pressure; specific components, such as the intra-renal monophasic pattern, portal-pulsatility, and inferior vena cava diameter, exhibited robust predictive value for venous congestion. Conclusion VExUS score is valuable in assessing and predicting venous congestion, especially regarding AKI prediction risk and guiding interventions. However, its utility in predicting outcomes in acute heart failure patients appears less certain.
Collapse
Affiliation(s)
- Bhavna Gupta
- Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Pallavi Ahluwalia
- Department of Anaesthesiology, Teerthanker Mahaveer Medical College, Moradabad, Uttar Pradesh, India
| | - Anish Gupta
- Department of Cardio Thoracic and Vascular Surgery, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Nikhil Ranjan
- Department of Anaesthesiology, Safdarjung Hospital, New Delhi, India
| | - Kamna Kakkar
- Department of Anaesthesiology, Safdarjung Hospital, New Delhi, India
| | - Parag Aneja
- Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| |
Collapse
|
7
|
Torres-Arrese M, Mata-Martínez A, Luordo-Tedesco D, García-Casasola G, Alonso-González R, Montero-Hernández E, Cobo-Marcos M, Sánchez-Sauce B, Cuervas-Mons V, Tung-Chen Y. Usefulness of Systemic Venous Ultrasound Protocols in the Prognosis of Heart Failure Patients: Results from a Prospective Multicentric Study. J Clin Med 2023; 12:jcm12041281. [PMID: 36835816 PMCID: PMC9966251 DOI: 10.3390/jcm12041281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/21/2023] [Accepted: 02/02/2023] [Indexed: 02/09/2023] Open
Abstract
Mortality and re-admission rates for decompensated acute heart failure (AHF) is increasing overall and risk stratification might be challenging. We sought to evaluate the prognostic role of systemic venous ultrasonography in patients hospitalized for AHF. We prospectively recruited 74 AHF patients with a NT-proBNP level above 500 pg/mL. Then, multi-organ ultrasound assessments (lung, inferior vena cava (IVC), pulsed-wave Doppler (PW-Doppler) of hepatic, portal, intra-renal and femoral veins) were performed at admission, discharge, and follow-up (for 90 days). We also calculated the Venous Excess Ultrasound System (VExUS), a new score of systemic congestion based on IVC dilatation and pulsed-wave Doppler morphology of hepatic, portal and intra-renal veins. An intra-renal monophasic pattern (area under the curve (AUC) 0.923, sensitivity (Sn) 90%, specificity (Sp) 81%, positive predictive value (PPV) 43%, and negative predictive value (NPV) 98%), a portal pulsatility > 50% (AUC 0.749, Sn 80%, Sp 69%, PPV 30%, NPV 96%) and a VExUS score of 3 corresponding to severe congestion (AUC 0.885, Sn 80%, Sp 75%, PPV 33%, and NPV 96%) predicted death during hospitalization. An IVC above 2 cm (AUC 0.758, Sn 93.l% and Sp 58.3) and the presence of an intra-renal monophasic pattern (AUC 0. 834, sensitivity 0.917, specificity 67.4%) in the follow-up visit predicted AHF-related re-admission. Additional scans during hospitalization or the calculation of a VExUS score probably adds unnecessary complexity to the assessment of AHF patients. In conclusion, VExUS score does not contribute to the guidance of therapy or the prediction of complications, compared with the presence of an IVC greater than 2 cm, a venous monophasic intra-renal pattern or a pulsatility > 50% of the portal vein in AHF patients. Early and multidisciplinary follow-up visits remain necessary for the improvement of the prognosis of this highly prevalent disease.
Collapse
Affiliation(s)
- Marta Torres-Arrese
- Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
| | - Arantzazu Mata-Martínez
- Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
| | - Davide Luordo-Tedesco
- Department of Emergency Medicine, Hospital Universitario Infanta Cristina, Avenida 9 de Junio 2, 28981 Parla, Spain
| | - Gonzalo García-Casasola
- Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
| | - Rodrigo Alonso-González
- Department of Radiology, Hospital Universitario Severo Ochoa, M-402, s/n, 28914 Leganés, Spain
| | - Esther Montero-Hernández
- Department of Internal Medicine, Hospital Universitario Puerta de Hierro–Majadahonda, Centro de Investigación en Red en Enfermedades Cardiovasculares (CIBERCV), Joaquín Rodrigo 1, 28222 Majadahonda, Spain
| | - Marta Cobo-Marcos
- Department of Cardiology, Hospital Universitario Puerta de Hierro–Majadahonda, Centro de Investigación en Red en Enfermedades Cardiovasculares (CIBERCV), Joaquín Rodrigo 1, 28222 Majadahonda, Spain
| | - Beatriz Sánchez-Sauce
- Department of Internal Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
| | - Valentín Cuervas-Mons
- Department of Internal Medicine, Hospital Universitario Puerta de Hierro–Majadahonda, Centro de Investigación en Red en Enfermedades Cardiovasculares (CIBERCV), Joaquín Rodrigo 1, 28222 Majadahonda, Spain
| | - Yale Tung-Chen
- Department of Internal Medicine, Hospital Universitario La Paz, Paseo Castellana 241, 28046 Madrid, Spain
- Department of Medicine, Universidad Alfonso X, 28691 Madrid, Spain
- Correspondence: ; Tel.: +34-676-030-131
| |
Collapse
|
8
|
Thota RS, Ramkiran S, Ramanjulu R. Time to FOCUS - 'Palliative Medicine Point-of-Care Ultrasound'. Indian J Palliat Care 2023; 29:36-45. [PMID: 36846289 PMCID: PMC9945239 DOI: 10.25259/ijpc_274_2022] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 12/13/2022] [Indexed: 01/15/2023] Open
Abstract
Point-of-care diagnosis has become the need of the hour and along with its guided interventions, ultrasound could be utilised bedside in a palliative care patient. Point-of-care ultrasound (POCUS) in palliative care medicine is fast emerging and has varied applications ranging from performing bedside diagnostic evaluation to the performance of interventional paracentesis, thoracocentesis and chronic pain interventions. Handheld ultrasound devices have transformed the application of POCUS and should revolutionise the future of home-based palliative care. Palliative care physicians should be enabled to carry out bedside ultrasounds at home care and hospice setting for achieving rapid symptom relief. The aim of POCUS in palliative care medicine should be adequate training of palliative care physicians, transforming the applicability of this technology to OPD as well as community driven to achieve home outreach. The goal is towards empowering technology by reaching out to the community rather than the terminally ill patient transported for the hospital admission. Palliative care physicians should receive mandatory training in POCUS to enable diagnostic proficiency and early triaging. The inclusion of ultrasound machine in an outpatient palliative care clinic brings about value addition in rapid diagnosis. Limiting POCUS application to certain selected sub-specialities such as emergency medicine, internal medicine and critical care medicine should be overcome. This would need acquiring higher training as well as improvised skill sets to perform bedside interventions. Ultrasonography competency among palliative care providers proposed as palliative medicine point-of-care ultrasound (PM-POCUS) could be achieved by imparting dedicated POCUS training within the core curriculum.
Collapse
Affiliation(s)
| | - Seshadri Ramkiran
- Department of Anaesthesia and Critical Care, HCG Cancer Hospital, Bengaluru, Karnataka, India
| | - Raghavendra Ramanjulu
- Department of Pain and Palliative Care, Aster Hospitals, Bengaluru, Karnataka, India
| |
Collapse
|