1
|
Albu PC, Pîrțac A, Motelica L, Nechifor AC, Man GT, Grosu AR, Tanczos SK, Grosu VA, Nechifor G. Reduction in Olfactory Discomfort in Inhabited Premises from Areas with Mofettas through Cellulosic Derivative-Polypropylene Hollow Fiber Composite Membranes. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4437. [PMID: 39274826 PMCID: PMC11396629 DOI: 10.3390/ma17174437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 09/03/2024] [Accepted: 09/05/2024] [Indexed: 09/16/2024]
Abstract
Hydrogen sulfide is present in active or extinct volcanic areas (mofettas). The habitable premises in these areas are affected by the presence of hydrogen sulfide, which, even in low concentrations, gives off a bad to unbearable smell. If the living spaces considered are closed enclosures, then a system can be designed to reduce the concentration of hydrogen sulfide. This paper presents a membrane-based way to reduce the hydrogen sulfide concentration to acceptable limits using a cellulosic derivative-propylene hollow fiber-based composite membrane module. The cellulosic derivatives considered were: carboxymethyl-cellulose (NaCMC), P1; cellulose acetate (CA), P2; methyl 2-hydroxyethyl-cellulose (MHEC), P3; and hydroxyethyl-cellulose (HEC), P4. In the permeation module, hydrogen sulfide is captured with a solution of cadmium that forms cadmium sulfide, usable as a luminescent substance. The composite membranes were characterized by SEM, EDAX, FTIR, FTIR 2D maps, thermal analysis (TG and DSC), and from the perspective of hydrogen sulfide air removal performance. To determine the process performances, the variables were as follows: the nature of the cellulosic derivative-polypropylene hollow fiber composite membrane, the concentration of hydrogen sulfide in the polluted air, the flow rate of polluted air, and the pH of the cadmium nitrate solution. The pertraction efficiency was highest for the sodium carboxymethyl-cellulose (NaCMC)-polypropylene hollow fiber membrane, with a hydrogen sulfide concentration in the polluted air of 20 ppm, a polluted air flow rate (QH2S) of 50 L/min, and a pH of 2 and 4. The hydrogen sulfide flux rates, for membrane P1, fall between 0.25 × 10-7 mol·m2·s-1 for the values of QH2S = 150 L/min, CH2S = 20 ppm, and pH = 2 and 0.67 × 10-7 mol·m-2·s-1 for the values of QH2S = 50 L/min, CH2S = 60 ppm, and pH = 2. The paper proposes a simple air purification system containing hydrogen sulfide, using a module with composite cellulosic derivative-polypropylene hollow fiber membranes.
Collapse
Affiliation(s)
- Paul Constantin Albu
- Radioisotopes and Radiation Metrology Department (DRMR), National Institute of Physics and Nuclear Engineering (IFIN) Horia Hulubei, 023465 Măgurele, Romania
| | - Andreia Pîrțac
- Analytical Chemistry and Environmental Engineering Department, National University of Science and Technology POLITEHNICA Bucharest, 011061 Bucharest, Romania
| | - Ludmila Motelica
- National Research Center for Micro and Nanomaterials, Department of Science and Engineering of Nanomaterials and Oxide Materials, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
| | - Aurelia Cristina Nechifor
- Analytical Chemistry and Environmental Engineering Department, National University of Science and Technology POLITEHNICA Bucharest, 011061 Bucharest, Romania
| | - Geani Teodor Man
- Analytical Chemistry and Environmental Engineering Department, National University of Science and Technology POLITEHNICA Bucharest, 011061 Bucharest, Romania
- National Research and Development Institute for Cryogenics and Isotopic Technologies-ICSI, 240050 Râmnicu-Vâlcea, Romania
| | - Alexandra Raluca Grosu
- Analytical Chemistry and Environmental Engineering Department, National University of Science and Technology POLITEHNICA Bucharest, 011061 Bucharest, Romania
| | - Szidonia-Katalin Tanczos
- Department of Bioengineering, University Sapientia of Miercurea-Ciuc, 500104 Miercurea-Ciuc, Romania
| | - Vlad-Alexandru Grosu
- Department of Electronic Technology and Reliability, Faculty of Electronics, Telecommunications and Information Technology, National University of Science and Technology POLITEHNICA Bucharest, 061071 Bucharest, Romania
| | - Gheorghe Nechifor
- National Research Center for Micro and Nanomaterials, Department of Science and Engineering of Nanomaterials and Oxide Materials, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
| |
Collapse
|
2
|
Man GT, Albu PC, Nechifor AC, Grosu AR, Popescu (Stegarus) DI, Grosu VA, Marinescu VE, Nechifor G. Simultaneously Recovery of Thorium and Tungsten through Hybrid Electrolysis-Nanofiltration Processes. TOXICS 2024; 12:103. [PMID: 38393198 PMCID: PMC10892189 DOI: 10.3390/toxics12020103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 01/13/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
The recovery and recycling of metals that generate toxic ions in the environment is of particular importance, especially when these are tungsten and, in particular, thorium. The radioactive element thorium has unexpectedly accessible domestic applications (filaments of light bulbs and electronic tubes, welding electrodes, and working alloys containing aluminum and magnesium), which lead to its appearance in electrical and electronic waste from municipal waste management platforms. The current paper proposes the simultaneous recovery of waste containing tungsten and thorium from welding electrodes. Simultaneous recovery is achieved by applying a hybrid membrane electrolysis technology coupled with nanofiltration. An electrolysis cell with sulphonated polyether-ether-ketone membranes (sPEEK) and a nanofiltration module with chitosan-polypropylene membranes (C-PHF-M) are used to carry out the hybrid process. The analysis of welding electrodes led to a composition of W (tungsten) 89.4%; Th 7.1%; O2 2.5%; and Al 1.1%. Thus, the parameters of the electrolysis process were chosen according to the speciation of the three metals suggested by the superimposed Pourbaix diagrams. At a constant potential of 20.0 V and an electrolysis current of 1.0 A, the pH is varied and the possible composition of the solution in the anodic workspace is analyzed. Favorable conditions for both electrolysis and nanofiltration were obtained at pH from 6 to 9, when the soluble tungstate ion, the aluminum hydroxide, and solid thorium dioxide were formed. Through the first nanofiltration, the tungstate ion is obtained in the permeate, and thorium dioxide and aluminum hydroxide in the concentrate. By adding a pH 13 solution over the two precipitates, the aluminum is solubilized as sodium aluminate, which will be found after the second nanofiltration in the permeate, with the thorium dioxide remaining integrally (within an error of ±0.1 ppm) on the C-PHF-M membrane.
Collapse
Affiliation(s)
- Geani Teodor Man
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania; (G.T.M.); (A.C.N.); (A.R.G.)
- National Research and Development Institute for Cryogenics and Isotopic Technologies–ICSI, 240050 Râmnicu Valcea, Romania;
| | - Paul Constantin Albu
- Radioisotopes and Radiation Metrology Department (DRMR), IFIN Horia Hulubei, 023465 Măgurele, Romania;
| | - Aurelia Cristina Nechifor
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania; (G.T.M.); (A.C.N.); (A.R.G.)
| | - Alexandra Raluca Grosu
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania; (G.T.M.); (A.C.N.); (A.R.G.)
| | | | - Vlad-Alexandru Grosu
- Department of Electronic Technology and Reliability, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 061071 Bucharest, Romania
| | - Virgil Emanuel Marinescu
- Department of Physical-Chemical Tests, National Institute for Research and Development in Electrical Engineering ICPE–CA Bucharest, 030138 Bucharest, Romania;
| | - Gheorghe Nechifor
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania; (G.T.M.); (A.C.N.); (A.R.G.)
| |
Collapse
|