1
|
Ferrari DDDM, Lima SC, Teixeira RLF, Lopes MQP, Vaconcellos SEG, Machado ES, Suffys PN, Gomes HM. Genetic Diversity of Legionella pneumophila Isolates from Artificial Water Sources in Brazil. Curr Microbiol 2024; 81:165. [PMID: 38714565 PMCID: PMC11076386 DOI: 10.1007/s00284-024-03645-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 02/19/2024] [Indexed: 05/10/2024]
Abstract
Legionella pneumophila (Lp) is a Gram-negative bacterium found in natural and artificial aquatic environments and inhalation of contaminated aerosols can cause severe pneumonia known as Legionnaires' Disease (LD). In Brazil there is hardly any information about this pathogen, so we studied the genetic variation of forty Legionella spp. isolates obtained from hotels, malls, laboratories, retail centers, and companies after culturing in BCYE medium. These isolates were collected from various sources in nine Brazilian states. Molecular identification of the samples was carried out using Sequence-Based Typing (SBT), which consists of sequencing and analysis of seven genes (flaA, pilE, asd, mip, mompS, proA, and neuA) to define a Sequence Type (ST). Eleven STs were identified among 34/40 isolates, of which eight have been previously described (ST1, ST80, ST152, ST242, ST664, ST1185, ST1464, ST1642) and three were new STs (ST2960, ST2962, and ST2963), the former identified in five different cooling towers in the city of São Paulo. The ST1 that is widely distributed in many countries was also the most prevalent in this study. In addition, other STs that we observed have also been associated with legionellosis in other countries, reinforcing the potential of these isolates to cause LD in Brazil. Unfortunately, no human isolates could be characterized until presently, but our observations strongly suggest the need of surveillance implementation system and control measures of Legionella spp. in Brazil, including the use of more sensitive genotyping procedures besides ST.
Collapse
Affiliation(s)
- Dândrea Driely de Melo Ferrari
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil.
| | | | - Raquel Lima Figueiredo Teixeira
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil
| | - Marcia Quinhones Pires Lopes
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil
| | | | - Edson Silva Machado
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil
| | - Philip Noel Suffys
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil.
| | - Harrison Magdinier Gomes
- Laboratório de Biologia Molecular Aplicada a Micobactérias, Instituto Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, 21040-360, Brazil.
| |
Collapse
|
2
|
Zayed AR, Burghal M, Butmeh S, Samba-Louaka A, Steinert M, Bitar DM. Legionella pneumophila Presence in Dental Unit Waterlines: A Cultural and Molecular Investigation in the West Bank, Palestine. Trop Med Infect Dis 2023; 8:490. [PMID: 37999609 PMCID: PMC10675536 DOI: 10.3390/tropicalmed8110490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/15/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023] Open
Abstract
A Legionella pneumophila bacterium is ubiquitous in water distribution systems, including dental unit waterlines (DUWLs). Legionellosis is atypical pneumonia, including Legionnaires' disease (LD) and the less acute form of Pontiac fever. Legionellosis occurs as a result of inhalation/aspiration of aerosolized Legionella-contaminated water by susceptible patients, health workers, and dentists. In this study, we undertook to determine the prevalence of Legionella in water and biofilm samples from Tap and DUWLs collected from five sites of dental clinics and faculties across the West Bank. Water samples were tested for physical and chemical parameters. The study samples included 185 samples, 89 (48%) water samples, and 96 (52%) biofilm swabs, which were analyzed by cultivation-dependent analysis (CDA) and by the cultivation-independent technique (CIA). Also, partial sequencing of the 16S rRNA gene for fifteen L. pneumophila isolates was performed for quality assurance and identification. L. pneumophila was isolated from 28 (15%) of 185 samples using CDA and was detected in 142 (77%) of 185 samples using CIA. The abundance of culturable L. pneumophila was low in DUWL of the sampling sites (range: 27-115 CFU/Liter). PCR was 5× more sensitive than the culture technique. L. pneumophila Sg 1 was detected in (75%) of the isolates, while (25%) isolates were L. pneumophila Sg 2-14. All fifteen sequenced Legionella isolates were identified as L. pneumophila ≥ 94.5%. The analysis of phylogenetic tree showed that L. pneumophila branch clearly identified and distinguished from other branches. These results show that DUWLs of the examined dental clinics and faculties are contaminated with L. pneumophila. This finding reveals a serious potential health risk for infection of immunocompromised patients and dentists' post-exposure.
Collapse
Affiliation(s)
- Ashraf R. Zayed
- Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, An-Najah National University, Nablus P.O. Box 7, Palestine
| | - Mutasem Burghal
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| | - Suha Butmeh
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| | - Ascel Samba-Louaka
- Laboratoire Ecologie et Biologie des Interactions, Université de Poitiers, UMR CNRS 7267, 86000 Poitiers, France;
| | - Michael Steinert
- Institut für Mikrobiologie, Technische Universität Braunschweig, 38106 Braunschweig, Germany;
| | - Dina M. Bitar
- Microbiology Research Laboratory, Faculty of Medicine, Al-Quds University, Abu-Dies, East Jerusalem P.O. Box 51000, Palestine; (M.B.); (S.B.)
| |
Collapse
|
3
|
Valciņa O, Pūle D, Ķibilds J, Lazdāne A, Trofimova J, Makarova S, Konvisers G, Ķimse L, Krūmiņa A, Bērziņš A. Prevalence and Genetic Diversity of Legionella spp. in Hotel Water-Supply Systems in Latvia. Microorganisms 2023; 11:microorganisms11030596. [PMID: 36985170 PMCID: PMC10055240 DOI: 10.3390/microorganisms11030596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 02/22/2023] [Accepted: 02/23/2023] [Indexed: 03/02/2023] Open
Abstract
Legionella is one of the most important waterborne pathogens that can lead to both outbreaks and sporadic cases. The majority of travel-associated Legionnaires’ disease (TALD) cases are contracted during hotel stays. The aim of this study was to evaluate the prevalence and genetic diversity of Legionella spp. in hotel water supply systems in Latvia. In total, 834 hot water samples were collected from the water systems of 80 hotels in Latvia. At least one Legionella spp. positive sample was detected in 47 out of 80 hotels (58.8%). Overall, 235 out of 834 samples (28.2%) were Legionella spp. positive. The average hot water temperature in Latvian hotels was 49.8 °C. The most predominant L. pneumophila serogroup (SG) was SG3 which was found in 113 (49.8%) positive samples from 27 hotels. For 79 sequenced L. pneumophila isolates, 21 different sequence types (ST) were obtained, including 3 new types—ST2582, ST2579, and ST2580. High Legionella contamination and high genetic diversity were found in the hotel water supply systems in Latvia, which, together with the insufficient hot water temperature, may indicate that the lack of regulation and control measures may promote the proliferation of Legionella.
Collapse
Affiliation(s)
- Olga Valciņa
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
| | - Daina Pūle
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
- Department of Water Engineering and Technology, Riga Technical University, 1048 Rīga, Latvia
| | - Juris Ķibilds
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
| | - Andžela Lazdāne
- Department of Metabolic Genetics Laboratory, Children’s Clinical University Hospital, 1004 Rīga, Latvia
| | - Jūlija Trofimova
- National Reference Laboratory, Riga East University Hospital, 1038 Rīga, Latvia
| | - Svetlana Makarova
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
| | - Genadijs Konvisers
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
| | - Laima Ķimse
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
| | - Angelika Krūmiņa
- Department of Infectology, Riga Stradiņš University, 1007 Rīga, Latvia
| | - Aivars Bērziņš
- Institute of Food Safety, Animal Health and Environment “BIOR”, 1076 Rīga, Latvia
- Correspondence: ; Tel.: +371-6780-8972
| |
Collapse
|
4
|
Zayed AR, Bunk B, Jaber L, Abu-Teer H, Ali M, Steinert M, Höfle MG, Brettar I, Bitar DM. Whole-genome sequencing of the clinical isolate of Legionella pneumophila ALAW1 from the West Bank allows high-resolution typing and determination of pathogenicity mechanisms. Eur Clin Respir J 2023; 10:2168346. [PMID: 36698751 PMCID: PMC9869991 DOI: 10.1080/20018525.2023.2168346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Background Legionella pneumophila is water-based bacterium causing Legionnaires' disease (LD). We describe the first documented case of nosocomial LD caused by L. pneumophila sequence type (ST) 461 and serogroup 6. The etiology of LD was confirmed by culturing the bronchoalveolar lavage sample retrieving L. pneumophila strain ALAW1. A 7-days treatment of the LD patient with Azithromycin and Levofloxacin allowed complete recovery. Methods In details, we sequenced the whole genome of the L. pneumophila ALAW1 using Illumina HiSeq platform. The sequence of ALAW1 was aligned with the genome sequence from the closely related reference strain Alcoy 2300/99 and a whole-genome phylogeny based on single nucleotide polymorphisms (SNPs) was created using Parsnp software. Also, the TYGS web-server was used in order to compare the genome with type strain. Results An analysis of the population structure by SNP and TYGS comparison clustered ALAW1 with the reference genome Alcoy 2300/99. Blastp analysis of the type IV secretion Dot/Icm system genes showed that these genes were highly conserved with (≤25%) structural differences at the protein level. Conclusions Overall, this study provides insights into detailed genome structure and demonstrated the value of whole-genome sequencing as the ultimate typing tool for Legionella.
Collapse
Affiliation(s)
- Ashraf R. Zayed
- CONTACT Ashraf R. Zayed Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, An-Najah National University, Nablus, P. O. Box. 7, Palestine;Microbiology Research laboratory Faculty of Medicine Al-Quds University Abu-Dies, East Jerusalem 9993100, Palestine Zayed
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Svetlicic E, Jaén-Luchoro D, Klobucar RS, Jers C, Kazazic S, Franjevic D, Klobucar G, Shelton BG, Mijakovic I. Genomic characterization and assessment of pathogenic potential of Legionella spp. isolates from environmental monitoring. Front Microbiol 2023; 13:1091964. [PMID: 36713227 PMCID: PMC9879626 DOI: 10.3389/fmicb.2022.1091964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 12/28/2022] [Indexed: 01/15/2023] Open
Abstract
Several species in the genus Legionella are known to cause an acute pneumonia when the aerosols containing the bacteria from man-made water systems are inhaled. The disease is usually caused by Legionella pneumophila, but other species have been implicated in the infection. The disease is frequently manifested as an outbreak, which means several people are affected when exposed to the common source of Legionella contamination. Therefor environmental surveillance which includes isolation and identification of Legionella is performed routinely. However, usually no molecular or genome-based methods are employed in further characterization of the isolates during routine environmental monitoring. During several years of such monitoring, isolates from different geographical locations were collected and 39 of them were sequenced by hybrid de novo approach utilizing short and long sequencing reads. In addition, the isolates were typed by standard culture and MALDI-TOF method. The sequencing reads were assembled and annotated to produce high-quality genomes. By employing discriminatory genome typing, four potential new species in the Legionella genus were identified, which are yet to be biochemically and morphologically characterized. Moreover, functional annotations concerning virulence and antimicrobial resistance were performed on the sequenced genomes. The study contributes to the knowledge on little-known non-pneumophila species present in man-made water systems and establishes support for future genetic relatedness studies as well as understanding of their pathogenic potential.
Collapse
Affiliation(s)
- Ema Svetlicic
- Novo Nordisk Foundation Center for Biosustainability, Kongens Lyngby, Denmark
| | - Daniel Jaén-Luchoro
- Department of Infectious Diseases (Sahlgrenska Academy) at the University of Gothenburg, Gothenburg, Sweden
| | | | - Carsten Jers
- Novo Nordisk Foundation Center for Biosustainability, Kongens Lyngby, Denmark
| | - Snjezana Kazazic
- Laboratory for Mass Spectrometry and Functional Proteomics, Ruder Boskovic Institute, Zagreb, Croatia
| | - Damjan Franjevic
- Division of Zoology, Department of Biology, Faculty of Science, University of Zagreb, Zagreb, Croatia
| | - Goran Klobucar
- Division of Zoology, Department of Biology, Faculty of Science, University of Zagreb, Zagreb, Croatia
| | | | - Ivan Mijakovic
- Novo Nordisk Foundation Center for Biosustainability, Kongens Lyngby, Denmark,Systems and Synthetic Biology Division, Department of Biology and Biological Engineering, Chalmers University of Technology, Gothenburg, Sweden,*Correspondence: Ivan Mijakovic,
| |
Collapse
|
6
|
ÖZİŞ M, KAYA H, BOZOK T, TEZCAN ÜLGER S, ASLAN G. Investigation of Legionella bacteria in water and cooling systems of a university in Turkey. KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNIVERSITESI TIP FAKÜLTESI DERGISI 2022. [DOI: 10.17517/ksutfd.1033028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Objectives: Colonization of Legionella in water systems is among the factors affecting the incidence of community and hospital-acquired pneumonia. In this study, it was aimed to investigate the presence of Legionella in the water and cooling systems of the inpatient services of the faculty of medicine hospital and the faculties of the university.
Material and Methods: The presence of Legionella was investigated in 418 water and swab samples were taken from the water and cooling systems of the inpatient services of X University Faculty of Medicine Research and Practice Hospital and 11 faculties of the university between February-October 2020. Collected water and swab samples were inoculated into BCYE medium and identification at the species and serogroups by latex agglutination test. In addition, rpoB sequencing was used to confirm these isolates.
Results: Legionella were isolated in four (4.1%) of the samples collected from the inpatient services of the hospital and in three (0.9%) of the samples collected from the faculties (n=321), in total seven (1.67%) samples. One of these isolates (14.3%) was grouped as L.pneumophila serogroup 2-14 and six (85.7%) as L.pneumophila serogroup 1 by latex agglutination test. Species identifications were consistent with sequence analysis results.
Conclusion: The isolation of L.pneumophila in samples taken from inpatient services at a higher rate than in faculties poses a great risk. Although the detection rate of Legionella in our study was low, we think that regular disinfection, follow-up and inspection of water and cooling systems may be effective in reducing Legionella-related pneumonias.
Collapse
Affiliation(s)
- Merve ÖZİŞ
- MERSİN ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, TIBBİ MİKROBİYOLOJİ ANABİLİM DALI
| | - Hamide KAYA
- MERSİN ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, TIBBİ MİKROBİYOLOJİ ANABİLİM DALI
| | - Taylan BOZOK
- MERSİN ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, TIBBİ MİKROBİYOLOJİ ANABİLİM DALI
| | - Seda TEZCAN ÜLGER
- MERSİN ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, TIBBİ MİKROBİYOLOJİ ANABİLİM DALI
| | - Gönül ASLAN
- MERSİN ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, TIBBİ MİKROBİYOLOJİ ANABİLİM DALI
| |
Collapse
|
7
|
Pereira A, Silva AR, Melo LF. Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands. Microorganisms 2021; 9:microorganisms9061212. [PMID: 34205095 PMCID: PMC8228026 DOI: 10.3390/microorganisms9061212] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 11/16/2022] Open
Abstract
Legionella is responsible for the life-threatening pneumonia commonly known as Legionnaires’ disease or legionellosis. Legionellosis is known to be preventable if proper measures are put into practice. Despite the efforts to improve preventive approaches, Legionella control remains one of the most challenging issues in the water treatment industry. Legionellosis incidence is on the rise and is expected to keep increasing as global challenges become a reality. This puts great emphasis on prevention, which must be grounded in strengthened Legionella management practices. Herein, an overview of field-based studies (the system as a test rig) is provided to unravel the common roots of research and the main contributions to Legionella’s understanding. The perpetuation of a water-focused monitoring approach and the importance of protozoa and biofilms will then be discussed as bottom-line questions for reliable Legionella real-field surveillance. Finally, an integrated monitoring model is proposed to study and control Legionella in water systems by combining discrete and continuous information about water and biofilm. Although the successful implementation of such a model requires a broader discussion across the scientific community and practitioners, this might be a starting point to build more consistent Legionella management strategies that can effectively mitigate legionellosis risks by reinforcing a pro-active Legionella prevention philosophy.
Collapse
|
8
|
Causes, Factors, and Control Measures of Opportunistic Premise Plumbing Pathogens—A Critical Review. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11104474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This review critically analyses the chemical and physical parameters that influence the occurrence of opportunistic pathogens in the drinking water distribution system, specifically in premise plumbing. A comprehensive literature review reveals significant impacts of water age, disinfectant residual (type and concentration), temperature, pH, and pipe materials. Evidence suggests that there is substantial interplay between these parameters; however, the dynamics of such relationships is yet to be elucidated. There is a correlation between premise plumbing system characteristics, including those featuring water and energy conservation measures, and increased water quality issues and public health concerns. Other interconnected issues exacerbated by high water age, such as disinfectant decay and reduced corrosion control efficiency, deserve closer attention. Some common features and trends in the occurrence of opportunistic pathogens have been identified through a thorough analysis of the available literature. It is proposed that the efforts to reduce or eliminate their incidence might best focus on these common features.
Collapse
|
9
|
Mazzotta M, Salaris S, Pascale MR, Girolamini L, Cristino S. Occurrence of Legionella spp. in Man-Made Water Sources: Isolates Distribution and Phylogenetic Characterization in the Emilia-Romagna Region. Pathogens 2021; 10:552. [PMID: 34063633 PMCID: PMC8147600 DOI: 10.3390/pathogens10050552] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 04/29/2021] [Accepted: 05/01/2021] [Indexed: 11/16/2022] Open
Abstract
Legionella species distribution in the Emilia-Romagna region, involving hospital (H) and community (C) environments, was conducted. Legionella culture, agglutination test, and mip-gene sequencing were applied on 240 isolates. The analysis showed a higher prevalence of non-Legionellapneumophila (n-Lp) species (84.1%) compared with L. pneumophila (Lp) (15.9%), with a higher frequency of n-Lp with respect to Lp species in both environments (77.6% and 96.4%, in H and C, respectively). The Shannon index showed a significant difference in Legionella distribution (p = 0.00017), with a significant abundance of Lp in the H compared with C environment (p = 0.00028). The continuous disinfection treatment in H could contribute to adaptive survival of the Lp species. Phylogenetic analysis revealed a conservative clade distribution between H and C: L. feeleii clade with three subclades in C and the Lp clade with five subclades in H and two in C, respectively. Our findings suggest the importance of Legionella surveillance both in H and C, with a focus on n-Lp species less connected to human disease. The Legionella prevalence and diversity found here indicate that geographical and temporal isolate evolution should be considered during surveillance, particularly in the light of global warming and changes in population risk factors.
Collapse
Affiliation(s)
| | | | | | | | - Sandra Cristino
- Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy; (M.M.); (S.S.); (M.R.P.); (L.G.)
| |
Collapse
|
10
|
Cytotoxicity, Intracellular Replication, and Contact-Dependent Pore Formation of Genotyped Environmental Legionella pneumophila Isolates from Hospital Water Systems in the West Bank, Palestine. Pathogens 2021; 10:pathogens10040417. [PMID: 33915921 PMCID: PMC8066006 DOI: 10.3390/pathogens10040417] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 03/15/2021] [Accepted: 03/28/2021] [Indexed: 12/02/2022] Open
Abstract
Legionella pneumophila is the causative agent of Legionnaires’ disease. Due to the hot climate and intermittent water supply, the West Bank, Palestine, can be considered a high-risk area for this often fatal atypical pneumonia. L. pneumophila occurs in biofilms of natural and man-made freshwater environments, where it infects and replicates intracellularly within protozoa. To correlate the genetic diversity of the bacteria in the environment with their virulence properties for protozoan and mammalian host cells, 60 genotyped isolates from hospital water systems in the West Bank were analyzed. The L. pneumophila isolates were previously genotyped by high resolution Multi Locus Variable Number of Tandem Repeat Analysis (MLVA-8(12)) and sorted according to their relationship in clonal complexes (VACC). Strains of relevant genotypes and VACCs were compared according to their capacity to infect Acanthamoeba castellanii and THP-1 macrophages, and to mediate pore-forming cytotoxicity in sheep red blood cells (sRBCs). Based on a previous detailed analysis of the biogeographic distribution and abundance of the MLVA-8(12)-genotypes, the focus of the study was on the most abundant L. pneumophila- genotypes Gt4(17), Gt6 (18) and Gt10(93) and the four relevant clonal complexes [VACC1, VACC2, VACC5 and VACC11]. The highly abundant genotypes Gt4(17) and Gt6(18) are affiliated with VACC1 and sequence type (ST)1 (comprising L. pneumophila str. Paris), and displayed seroroup (Sg)1. Isolates of these two genotypes exhibited significantly higher virulence potentials compared to other genotypes and clonal complexes in the West Bank. Endemic for the West Bank was the clonal complex VACC11 (affiliated with ST461) represented by three relevant genotypes that all displayed Sg6. These genotypes unique for the West Bank showed a lower infectivity and cytotoxicity compared to all other clonal complexes and their affiliated genotypes. Interestingly, the L. pneumophila serotypes ST1 and ST461 were previously identified by in situ-sequence based typing (SBT) as main causative agents of Legionnaires’ disease (LD) in the West Bank at a comparable level. Overall, this study demonstrates the site-specific regional diversity of L. pneumophila genotypes in the West Bank and suggests that a combination of MLVA, cellular infection assays and hierarchical agglomerative cluster analysis allows an improved genotype-based risk assessment.
Collapse
|
11
|
Leftwich B, Opoku ST, Yin J, Adhikari A. Assessing Hotel Employee Knowledge on Risk Factors and Risk Management Procedures for Microbial Contamination of Hotel Water Distribution Systems. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:3539. [PMID: 33805459 PMCID: PMC8037688 DOI: 10.3390/ijerph18073539] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/13/2021] [Accepted: 03/25/2021] [Indexed: 11/16/2022]
Abstract
Water management plans (WMPs), sometimes referred to as risk management plans (RMPs) or water safety plans (WSPs), are not mandatory for hotels in many countries of the world, including the US. As such, many hotel personnel are uninformed of WMPs and the precautions to take if their hotel water system is compromised. The purpose of this study was to identify hotel personnel's knowledge and practices of WMPs through a survey incorporating the Health Belief Model (HBM). Data were collected from 59 hotels within Fulton County, Georgia, USA, through a questionnaire, and questions were developed tailored to the HBM. Significant associations were found between the perceived susceptibility of contracting a waterborne illness and WMP for hotel personnel as well as between cues to action and having a WMP in general linear models (p ≤ 0.05). The study concludes that many key personnel are not aware of WMPs. Many hotel facilities do not have a plan in place, and some facilities are unaware of a current plan is in place. The study findings provide insight into the importance of WMPs and the risk factors associated with microbial contamination in a hotel building's plumbing system. Future research and potential law change should be emphasized to increase hotel employees' and owner's WMP knowledge.
Collapse
Affiliation(s)
- Brandon Leftwich
- Department of Health Policy and Community Health, Jiann-Ping Hsu College of Public Health, Georgia Southern University, Statesboro, GA 30460, USA; (B.L.); (S.T.O.)
| | - Samuel T. Opoku
- Department of Health Policy and Community Health, Jiann-Ping Hsu College of Public Health, Georgia Southern University, Statesboro, GA 30460, USA; (B.L.); (S.T.O.)
| | - Jingjing Yin
- Department of Biostatistics, Epidemiology, and Environmental Health Sciences, Jiann-Ping Hsu College of Public Health, Georgia Southern University, Statesboro, GA 30460, USA;
| | - Atin Adhikari
- Department of Biostatistics, Epidemiology, and Environmental Health Sciences, Jiann-Ping Hsu College of Public Health, Georgia Southern University, Statesboro, GA 30460, USA;
| |
Collapse
|
12
|
Editorial Comments to the Special Issue: " Legionella Contamination in Water Environment". Pathogens 2020; 9:pathogens9121017. [PMID: 33276607 PMCID: PMC7761553 DOI: 10.3390/pathogens9121017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 12/01/2020] [Indexed: 11/29/2022] Open
|