1
|
Fenniche F, Khane Y, Aouf D, Albukhaty S, Nouasria FZ, Chouireb M, Harfouche N, Henni A, Sulaiman GM, Jabir MS, Mohammed HA, Abomughaid MM. Electrochemical study of an enhanced platform by electrochemical synthesis of three-dimensional polyaniline nanofibers/reduced graphene oxide thin films for diverse applications. Sci Rep 2024; 14:26408. [PMID: 39488583 PMCID: PMC11531504 DOI: 10.1038/s41598-024-77252-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Accepted: 10/21/2024] [Indexed: 11/04/2024] Open
Abstract
This work reports the electrochemical fabrication of thin films comprising polyaniline nanofibers (PANI) in conjunction with graphene oxide (GO) and reduced graphene oxide (rGO) on ITO substrate, along with examining the electrochemical properties, with a focus on the influence of the substrate and electrolyte in the electrodeposition methods. The study explores the electrochemical characteristics of these thin films and establishes a flexible framework for their application in diverse sectors such as sensors, supercapacitors, and electronic devices. It analyzes the impact of the substrate and electrolyte in electrodeposition techniques. The effects were studied using techniques such as cyclic voltammetry and chronoamperometry. The fabrication process of PANI/GO and PANI/rGO thin films involved the integration of rGO within PANI via electropolymerization, conducted under sulfuric acid. GO was synthesized by modifying the well-known Hummers' method and characterized by X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). SEM showed the diameters of the formed PANI were between 40 and 150 nm, which helped to intertwine the rGO nanosheets with PANI nanofibers to form thin films. The electrochemical behavior of the PANI/rGO thin films was examined using cyclic voltammetry (CV) and chronoamperometry in different electrolytes, including sulfuric acid (H₂SO₄) and potassium nitrate (KNO₃). The CV profiles exhibited distinct oxidation and reduction peaks, with variations in the voltammogram morphology attributed to the nature of the electrolyte and the substrate employed during the electrodeposition process. These results highlight the critical role of both the substrate and electrolyte in governing the electrochemical performance of PANI/rGO thin films. The findings from this study demonstrate a versatile approach for the fabrication of PANI/graphene-based thin films with tunable electrochemical properties, and such a strategy has great application to fabricating other thin film composites for supercapacitors or other control source frameworks requiring enhanced charge storage and electrochemical responsiveness.
Collapse
Affiliation(s)
- Fares Fenniche
- Materials, Energy Systems Technology and Environment Laboratory, Faculty of Sciences and Technology, University of Ghardaia, 47000, Ghardaia, Algeria.
- Department of Process Engineering, Faculty of Sciences and Technology, University of Ghardaïa, BP 455, 47000, Ghardaïa, Algeria.
| | - Yasmina Khane
- Materials, Energy Systems Technology and Environment Laboratory, Faculty of Sciences and Technology, University of Ghardaia, 47000, Ghardaia, Algeria
- University of Ghardaïa, BP 455, 47000, Ghardaïa, Algeria
| | - Djaber Aouf
- Laboratory of Dynamic Interactions and Reactivity of Systems, University of Kasdi Merbah, 30000, Ouargla, Algeria
| | - Salim Albukhaty
- Department of Chemistry, College of Science, University of Misan, Maysan, 62001, Iraq.
- Al-Manara College for Medical Sciences, Maysan, 62001, Iraq.
| | - Fatima Zohra Nouasria
- Process Engineering Laboratory (PEL), Kasdi Merbah University, 30000, Ouargla, Algeria
| | - Makhlouf Chouireb
- Laboratoire Algérienne Des Eaux (ADE), l'unité de Ghardaïa, Ghardaïa, Algeria
| | - Nesrine Harfouche
- Laboratoire Matériaux Polymères-Interfaces-Environnement Marin, Université du Sud Toulon, Var, BP 132, La Garde Cedex, 83957, France
| | - Abdellah Henni
- Laboratory of Dynamic Interactions and Reactivity of Systems, University of Kasdi Merbah, 30000, Ouargla, Algeria
| | - Ghassan M Sulaiman
- Division of Biotechnology, Department of Applied Sciences, University of Technology, Baghdad, 10066, Iraq.
| | - Majid S Jabir
- Division of Biotechnology, Department of Applied Sciences, University of Technology, Baghdad, 10066, Iraq
| | - Hamdoon A Mohammed
- Department of Medicinal Chemistry and Pharmacognosy, College of Pharmacy, Qassim University, 51452, Buraydah, Saudi Arabia
| | - Mosleh M Abomughaid
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, University of Bisha, 255, 67714, Bisha, Saudi Arabia
| |
Collapse
|
2
|
Zhang X, Tan X, Wang P, Qin J. Application of Polypyrrole-Based Electrochemical Biosensor for the Early Diagnosis of Colorectal Cancer. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:674. [PMID: 36839042 PMCID: PMC9967576 DOI: 10.3390/nano13040674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/06/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Although colorectal cancer (CRC) is easy to treat surgically and can be combined with postoperative chemotherapy, its five-year survival rate is still not optimistic. Therefore, developing sensitive, efficient, and compliant detection technology is essential to diagnose CRC at an early stage, providing more opportunities for effective treatment and intervention. Currently, the widely used clinical CRC detection methods include endoscopy, stool examination, imaging modalities, and tumor biomarker detection; among them, blood biomarkers, a noninvasive strategy for CRC screening, have shown significant potential for early diagnosis, prediction, prognosis, and staging of cancer. As shown by recent studies, electrochemical biosensors have attracted extensive attention for the detection of blood biomarkers because of their advantages of being cost-effective and having sound sensitivity, good versatility, high selectivity, and a fast response. Among these, nano-conductive polymer materials, especially the conductive polymer polypyrrole (PPy), have been broadly applied to improve sensing performance due to their excellent electrical properties and the flexibility of their surface properties, as well as their easy preparation and functionalization and good biocompatibility. This review mainly discusses the characteristics of PPy-based biosensors, their synthetic methods, and their application for the detection of CRC biomarkers. Finally, the opportunities and challenges related to the use of PPy-based sensors for diagnosing CRC are also discussed.
Collapse
|