1
|
Lin Q, Sijbers W, Avdikou C, Gomez D, Biswas D, Tacca B, Van Helleputte N. A Multichannel Electrochemical Sensor Interface IC for Bioreactor Monitoring. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:1227-1236. [PMID: 37708009 DOI: 10.1109/tbcas.2023.3315480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
This research article introduces a novel integrated circuit (IC) designed for bioreactor applications catering to multichannel electrochemical sensing. The proposed IC comprises 2x potentiometric, 2x potentiostat, 2x ISFET channels and 1x temperature channel. The potentiostat channel utilizes a current conveyor-based architecture with a programmable mirroring ratio, enabling an extensive measurement range of 114 dB. The potentiometric channel incorporates a customized electrostatic discharge (ESD) protection circuit to achieve ultra-low input leakage in the picoampere range, while the ISFET channel employs a constant-voltage, constant-current topology for accurate pH measurement. Combined with the die temperature sensor, this IC is well-suited for monitoring bioreactions in real-time. Additionally, all channels can be time-multiplexed to a reconfigurable analog backend, facilitating the conversion of input signals into digital codes. The prototype of the IC is fabricated using 0.18 μm standard CMOS technology, and each channel is experimentally characterized. The interface IC demonstrates a peak power consumption of 22 μW.
Collapse
|
2
|
A Printed Organic Circuit System for Wearable Amperometric Electrochemical Sensors. Sci Rep 2018; 8:6368. [PMID: 29686355 PMCID: PMC5913266 DOI: 10.1038/s41598-018-24744-x] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 04/04/2018] [Indexed: 11/08/2022] Open
Abstract
Wearable sensor device technologies, which enable continuous monitoring of biological information from the human body, are promising in the fields of sports, healthcare, and medical applications. Further thinness, light weight, flexibility and low-cost are significant requirements for making the devices attachable onto human tissues or clothes like a patch. Here we demonstrate a flexible and printed circuit system consisting of an enzyme-based amperometric sensor, feedback control and amplification circuits based on organic thin-film transistors. The feedback control and amplification circuits based on pseudo-CMOS inverters were successfuly integrated by printing methods on a plastic film. This simple system worked very well like a potentiostat for electrochemical measurements, and enabled the quantitative and real-time measurement of lactate concentration with high sensitivity of 1 V/mM and a short response time of a hundred seconds.
Collapse
|
3
|
Ghodsevali E, Morneau-Gamache S, Mathault J, Landari H, Boisselier É, Boukadoum M, Gosselin B, Miled A. Miniaturized FDDA and CMOS Based Potentiostat for Bio-Applications. SENSORS 2017; 17:s17040810. [PMID: 28394289 PMCID: PMC5422171 DOI: 10.3390/s17040810] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Revised: 04/04/2017] [Accepted: 04/08/2017] [Indexed: 11/16/2022]
Abstract
A novel fully differential difference CMOS potentiostat suitable for neurotransmitter sensing is presented. The described architecture relies on a fully differential difference amplifier (FDDA) circuit to detect a wide range of reduction-oxidation currents, while exhibiting low-power consumption and low-noise operation. This is made possible thanks to the fully differential feature of the FDDA, which allows to increase the source voltage swing without the need for additional dedicated circuitry. The FDDA also reduces the number of amplifiers and passive elements in the potentiostat design, which lowers the overall power consumption and noise. The proposed potentiostat was fabricated in 0.18 µm CMOS, with 1.8 V supply voltage. The device achieved 5 µA sensitivity and 0.99 linearity. The input-referred noise was 6.9 µV rms and the flicker noise was negligible. The total power consumption was under 55 µW. The complete system was assembled on a 20 mm × 20 mm platform that includes the potentiostat chip, the electrode terminals and an instrumentation amplifier for redox current buffering, once converted to a voltage by a series resistor. the chip dimensions were 1 mm × 0.5 mm and the other PCB components were off-chip resistors, capacitors and amplifiers for data acquisition. The system was successfully tested with ferricyanide, a stable electroactive compound, and validated with dopamine, a popular neurotransmitter.
Collapse
Affiliation(s)
- Elnaz Ghodsevali
- LABioTRON Bioeng. Research Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Samuel Morneau-Gamache
- LABioTRON Bioeng. Research Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
- Ophthalmology Department, Faculty of Medicine, Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Jessy Mathault
- LABioTRON Bioeng. Research Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Hamza Landari
- LABioTRON Bioeng. Research Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Élodie Boisselier
- Ophthalmology Department, Faculty of Medicine, Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Mounir Boukadoum
- CoFaMic, Université du Québec à Montréal, Montreal, QC H2L 2C4, Canada.
| | - Benoit Gosselin
- Biomedical Microsystems Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
| | - Amine Miled
- LABioTRON Bioeng. Research Laboratory, ECE Dept. Université Laval, Québec City, QC G1V 0A6, Canada.
| |
Collapse
|
4
|
Ghafar-Zadeh E. Wireless integrated biosensors for point-of-care diagnostic applications. SENSORS 2015; 15:3236-61. [PMID: 25648709 PMCID: PMC4367357 DOI: 10.3390/s150203236] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2014] [Accepted: 12/03/2014] [Indexed: 11/16/2022]
Abstract
Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer's. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field.
Collapse
Affiliation(s)
- Ebrahim Ghafar-Zadeh
- Department of Electrical Engineering and Computer Sciences, Lassonde School of Engineering, York University, Toronto, ON M3J1P3, Canada.
| |
Collapse
|