1
|
Ślot K, Łuczak P, Kapusta P, Hausman S, Rantala A, Flak J. Very-Large-Scale Integration-Friendly Method for Vital Activity Detection with Frequency-Modulated Continuous Wave Radars. SENSORS (BASEL, SWITZERLAND) 2025; 25:2151. [PMID: 40218666 PMCID: PMC11991242 DOI: 10.3390/s25072151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2025] [Revised: 03/21/2025] [Accepted: 03/26/2025] [Indexed: 04/14/2025]
Abstract
A simple algorithm for respiratory activity detection in data produced by Frequency-Modulated Continuous-Wave (FMCW) radars is presented in this paper. The proposed computational architecture can be directly mapped onto custom digital-analog VLSI hardware, which is a unique approach in research on intelligent FMCW sensor development, offering a potential energy-efficient data analysis solution for target applications, such as preventing human trafficking or providing life-sign detection under limited visibility. The algorithm comprises two main modules. The first one summarizes radar-produced data into a descriptor reflecting the amount of motion that occurs within appropriately determined time intervals. The second one classifies a sequence of the produced descriptors using a recurrent neural network composed of gated recurrent units. To ensure the algorithm's implementation feasibility, an analog VLSI circuit comprising its main functional blocks has been designed, manufactured, and tested, providing constraints for neural model derivation. The adverse effects of the primary constraint, the severe restriction on admissible weight resolution, have been handled by introducing a novel training loss component and a simple mechanism for diversifying the effective weight sets of different network neurons. Experimental evaluation of the presented method, performed using the dataset of indoor recordings, indicates that the proposed simple, hardware implementation-friendly algorithm provides over 94% human detection accuracy and similar F1 scores.
Collapse
Affiliation(s)
- Krzysztof Ślot
- Institute of Applied Computer Science, Lodz University of Technology, Stefanowskiego 18, 90-537 Łódź, Poland; (K.Ś.); (P.K.)
| | - Piotr Łuczak
- Institute of Applied Computer Science, Lodz University of Technology, Stefanowskiego 18, 90-537 Łódź, Poland; (K.Ś.); (P.K.)
| | - Paweł Kapusta
- Institute of Applied Computer Science, Lodz University of Technology, Stefanowskiego 18, 90-537 Łódź, Poland; (K.Ś.); (P.K.)
| | - Sławomir Hausman
- Institute of Electronics, Lodz University of Technology, Aleje Politechniki 10, 90-537 Łódź, Poland;
| | - Arto Rantala
- VTT Technical Research Centre of Finland Ltd., P.O. Box 1000, FI-02044 Espoo, Finland; (A.R.); (J.F.)
| | - Jacek Flak
- VTT Technical Research Centre of Finland Ltd., P.O. Box 1000, FI-02044 Espoo, Finland; (A.R.); (J.F.)
| |
Collapse
|
2
|
Vinicius da Silva Ferreira M, Barbosa JL, Kamruzzaman M, Barbin DF. Low-cost electronic-nose (LC-e-nose) systems for the evaluation of plantation and fruit crops: recent advances and future trends. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6120-6138. [PMID: 37937362 DOI: 10.1039/d3ay01192e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
An electronic nose (e-nose) is a device designed to recognize and classify odors. The equipment is built around a series of sensors that detect the presence of odors, especially volatile organic compounds (VOCs), and generate an electric signal (voltage), known as e-nose data, which contains chemical information. In the food business, the use of e-noses for analyses and quality control of fruits and plantation crops has increased in recent years. Their use is particularly relevant due to the lack of non-invasive and inexpensive methods to detect VOCs in crops. However, the majority of reports in the literature involve commercial e-noses, with only a few studies addressing low-cost e-nose (LC-e-nose) devices or providing a data-oriented description to assist researchers in choosing their setup and appropriate statistical methods to analyze crop data. Therefore, the objective of this study is to discuss the hardware of the two most common e-nose sensors: electrochemical (EC) sensors and metal oxide sensors (MOSs), as well as a critical review of the literature reporting MOS-based low-cost e-nose devices used for investigating plantations and fruit crops, including the main features of such devices. Miniaturization of equipment from lab-scale to portable and convenient gear, allowing producers to take it into the field, as shown in many appraised systems, is one of the future advancements in this area. By utilizing the low-cost designs provided in this review, researchers can develop their own devices based on practical demands such as quality control and compare results with those reported in the literature. Overall, this review thoroughly discusses the applications of low-cost e-noses based on MOSs for fruits, tea, and coffee, as well as the key features of their equipment (i.e., advantages and disadvantages) based on their technical parameters (i.e., electronic and physical parts). As a final remark, LC-e-nose technology deserves significant attention as it has the potential to be a valuable quality control tool for emerging countries.
Collapse
Affiliation(s)
- Marcus Vinicius da Silva Ferreira
- Universidade Federal Rural do Rio de Janeiro (UFRRJ), Departamento de Tecnologia de Alimentos, Seropédica 23890-000, Rio de Janeiro, Brazil.
- Department of Agriculture and Biological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Jose Lucena Barbosa
- Universidade Federal Rural do Rio de Janeiro (UFRRJ), Departamento de Tecnologia de Alimentos, Seropédica 23890-000, Rio de Janeiro, Brazil.
| | - Mohammed Kamruzzaman
- Department of Agriculture and Biological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Douglas Fernandes Barbin
- Department of Food Engineering and Technology, School of Food Engineering, University of Campinas, Campinas, SP, Brazil
| |
Collapse
|
3
|
McDonnell KJ. Leveraging the Academic Artificial Intelligence Silecosystem to Advance the Community Oncology Enterprise. J Clin Med 2023; 12:4830. [PMID: 37510945 PMCID: PMC10381436 DOI: 10.3390/jcm12144830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/05/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023] Open
Abstract
Over the last 75 years, artificial intelligence has evolved from a theoretical concept and novel paradigm describing the role that computers might play in our society to a tool with which we daily engage. In this review, we describe AI in terms of its constituent elements, the synthesis of which we refer to as the AI Silecosystem. Herein, we provide an historical perspective of the evolution of the AI Silecosystem, conceptualized and summarized as a Kuhnian paradigm. This manuscript focuses on the role that the AI Silecosystem plays in oncology and its emerging importance in the care of the community oncology patient. We observe that this important role arises out of a unique alliance between the academic oncology enterprise and community oncology practices. We provide evidence of this alliance by illustrating the practical establishment of the AI Silecosystem at the City of Hope Comprehensive Cancer Center and its team utilization by community oncology providers.
Collapse
Affiliation(s)
- Kevin J McDonnell
- Center for Precision Medicine, Department of Medical Oncology & Therapeutics Research, City of Hope Comprehensive Cancer Center, Duarte, CA 91010, USA
| |
Collapse
|
4
|
Bertacco R, Panaccione G, Picozzi S. From Quantum Materials to Microsystems. MATERIALS (BASEL, SWITZERLAND) 2022; 15:4478. [PMID: 35806603 PMCID: PMC9267837 DOI: 10.3390/ma15134478] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/21/2022] [Accepted: 06/21/2022] [Indexed: 12/04/2022]
Abstract
The expression "quantum materials" identifies materials whose properties "cannot be described in terms of semiclassical particles and low-level quantum mechanics", i.e., where lattice, charge, spin and orbital degrees of freedom are strongly intertwined. Despite their intriguing and exotic properties, overall, they appear far away from the world of microsystems, i.e., micro-nano integrated devices, including electronic, optical, mechanical and biological components. With reference to ferroics, i.e., functional materials with ferromagnetic and/or ferroelectric order, possibly coupled to other degrees of freedom (such as lattice deformations and atomic distortions), here we address a fundamental question: "how can we bridge the gap between fundamental academic research focused on quantum materials and microsystems?". Starting from the successful story of semiconductors, the aim of this paper is to design a roadmap towards the development of a novel technology platform for unconventional computing based on ferroic quantum materials. By describing the paradigmatic case of GeTe, the father compound of a new class of materials (ferroelectric Rashba semiconductors), we outline how an efficient integration among academic sectors and with industry, through a research pipeline going from microscopic modeling to device applications, can bring curiosity-driven discoveries to the level of CMOS compatible technology.
Collapse
Affiliation(s)
- Riccardo Bertacco
- Dipartimento di Fisica, Politecnico di Milano, 20133 Milan, Italy
- Istituto di Fotonica e Nanotecnologie CNR-IFN, 20133 Milan, Italy
| | | | - Silvia Picozzi
- Consiglio Nazionale delle Ricerche, CNR-SPIN c/o Università G. D’Annunzio, 66100 Chieti, Italy;
| |
Collapse
|
5
|
CMOS Perceptron for Vesicle Fusion Classification. ELECTRONICS 2022. [DOI: 10.3390/electronics11060843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Edge computing (processing data close to its source) is one of the fastest developing areas of modern electronics and hardware information technology. This paper presents the implementation process of an analog CMOS preprocessor for use in a distributed environment for processing medical data close to the source. The task of the circuit is to analyze signals of vesicle fusion, which is the basis of life processes in multicellular organisms. The functionality of the preprocessor is based on a classifier of full and partial fusions. The preprocessor is dedicated to operate in amperometric systems, and the analyzed signals are data from carbon nanotube electrodes. The accuracy of the classifier is at the level of 93.67%. The implementation was performed in the 65 nm CMOS technology with a 0.3 V power supply. The circuit operates in the weak-inversion mode and is dedicated to be powered by thermal cells of the human energy harvesting class. The maximum power consumption of the circuit equals 416 nW, which makes it possible to use it as an implantable chip. The results can be used, among others, in the diagnosis of precancerous conditions.
Collapse
|
6
|
Li P, Ren Z, Shao K, Tan H, Niu Z. Research on Distinguishing Fish Meal Quality Using Different Characteristic Parameters Based on Electronic Nose Technology. SENSORS 2019; 19:s19092146. [PMID: 31075849 PMCID: PMC6540599 DOI: 10.3390/s19092146] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 04/26/2019] [Accepted: 05/07/2019] [Indexed: 11/16/2022]
Abstract
In this paper, a portable electronic nose, that was independently developed, was employed to detect and classify a fish meal of different qualities. SPME-GC-MS (solid phase microextraction gas chromatography mass spectrometry) analysis of fish meal was presented. Due to the large amount of data of the original features detected by the electronic nose, a reasonable selection of the original features was necessary before processing, so as to reduce the dimension. The integral value, wavelet energy value, maximum gradient value, average differential value, relation steady-state response average value and variance value were selected as six different characteristic parameters, to study fish meal samples with different storage time grades. Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA), and five recognition modes, which included the multilayer perceptron neural network classification method, random forest classification method, k nearest neighbor algorithm, support vector machine algorithm, and Bayesian classification method, were employed for the classification. The result showed that the RF classification method had the highest accuracy rate for the classification algorithm. The highest accuracy rate for distinguishing fish meal samples with different qualities was achieved using the integral value, stable value, and average differential value. The lowest accuracy rate for distinguishing fish meal samples with different qualities was achieved using the maximum gradient value. This finding shows that the electronic nose can identify fish meal samples with different storage times.
Collapse
Affiliation(s)
- Pei Li
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
| | - Zouhong Ren
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
| | - Kaiyi Shao
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
| | - Hequn Tan
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
- Key Laboratory of Agricultural Equipment in Mid-lower Yangtze River, Ministry of Agriculture, Wuhan 430070, China.
| | - Zhiyou Niu
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
- Key Laboratory of Agricultural Equipment in Mid-lower Yangtze River, Ministry of Agriculture, Wuhan 430070, China.
| |
Collapse
|
7
|
An Investigation into Spike-Based Neuromorphic Approaches for Artificial Olfactory Systems. SENSORS 2017; 17:s17112591. [PMID: 29125586 PMCID: PMC5713038 DOI: 10.3390/s17112591] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 11/06/2017] [Accepted: 11/07/2017] [Indexed: 02/07/2023]
Abstract
The implementation of neuromorphic methods has delivered promising results for vision and auditory sensors. These methods focus on mimicking the neuro-biological architecture to generate and process spike-based information with minimal power consumption. With increasing interest in developing low-power and robust chemical sensors, the application of neuromorphic engineering concepts for electronic noses has provided an impetus for research focusing on improving these instruments. While conventional e-noses apply computationally expensive and power-consuming data-processing strategies, neuromorphic olfactory sensors implement the biological olfaction principles found in humans and insects to simplify the handling of multivariate sensory data by generating and processing spike-based information. Over the last decade, research on neuromorphic olfaction has established the capability of these sensors to tackle problems that plague the current e-nose implementations such as drift, response time, portability, power consumption and size. This article brings together the key contributions in neuromorphic olfaction and identifies future research directions to develop near-real-time olfactory sensors that can be implemented for a range of applications such as biosecurity and environmental monitoring. Furthermore, we aim to expose the computational parallels between neuromorphic olfaction and gustation for future research focusing on the correlation of these senses.
Collapse
|
8
|
Evaluating Soil Moisture Status Using an e-Nose. SENSORS 2016; 16:s16060886. [PMID: 27338404 PMCID: PMC4934312 DOI: 10.3390/s16060886] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 06/01/2016] [Accepted: 06/08/2016] [Indexed: 02/05/2023]
Abstract
The possibility of distinguishing different soil moisture levels by electronic nose (e-nose) was studied. Ten arable soils of various types were investigated. The measurements were performed for air-dry (AD) soils stored for one year, then moistened to field water capacity and finally dried within a period of 180 days. The volatile fingerprints changed during the course of drying. At the end of the drying cycle, the fingerprints were similar to those of the initial AD soils. Principal component analysis (PCA) and artificial neural network (ANN) analysis showed that e-nose results can be used to distinguish soil moisture. It was also shown that different soils can give different e-nose signals at the same moistures.
Collapse
|
9
|
de Araújo Júnior JM, de Menezes Júnior JMP, de Albuquerque AAM, Almeida ODM, de Araújo FMU. Assessment and certification of neonatal incubator sensors through an inferential neural network. SENSORS 2013; 13:15613-32. [PMID: 24248278 PMCID: PMC3871086 DOI: 10.3390/s131115613] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 10/12/2013] [Accepted: 10/12/2013] [Indexed: 12/05/2022]
Abstract
Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal.
Collapse
Affiliation(s)
- José Medeiros de Araújo Júnior
- Electrical Engineering Course, Federal University of Piauí (UFPI), 64049-550, Teresina, Piauí, Brazil; E-Mails: (J.M.P.M.J.); (O.M.A.)
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +55-86-3237-1555
| | | | | | - Otacílio da Mota Almeida
- Electrical Engineering Course, Federal University of Piauí (UFPI), 64049-550, Teresina, Piauí, Brazil; E-Mails: (J.M.P.M.J.); (O.M.A.)
| | - Fábio Meneghetti Ugulino de Araújo
- Department of Computer Engineering and Automation, Federal University of Rio Grande do Norte (UFRN), 59078-900, Natal, Rio Grande do Norte, Brazil; E-Mail:
| |
Collapse
|
10
|
Chiu SW, Tang KT. Towards a chemiresistive sensor-integrated electronic nose: a review. SENSORS (BASEL, SWITZERLAND) 2013; 13:14214-47. [PMID: 24152879 PMCID: PMC3859118 DOI: 10.3390/s131014214] [Citation(s) in RCA: 141] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Revised: 09/28/2013] [Accepted: 10/09/2013] [Indexed: 01/17/2023]
Abstract
Electronic noses have potential applications in daily life, but are restricted by their bulky size and high price. This review focuses on the use of chemiresistive gas sensors, metal-oxide semiconductor gas sensors and conductive polymer gas sensors in an electronic nose for system integration to reduce size and cost. The review covers the system design considerations and the complementary metal-oxide-semiconductor integrated technology for a chemiresistive gas sensor electronic nose, including the integrated sensor array, its readout interface, and pattern recognition hardware. In addition, the state-of-the-art technology integrated in the electronic nose is also presented, such as the sensing front-end chip, electronic nose signal processing chip, and the electronic nose system-on-chip.
Collapse
Affiliation(s)
- Shih-Wen Chiu
- Department of Electrical Engineering, National Tsing Hua University/No. 101, Sec. 2, Kuang-Fu Road, Hsinchu 30013, Taiwan; E-Mail:
| | - Kea-Tiong Tang
- Department of Electrical Engineering, National Tsing Hua University/No. 101, Sec. 2, Kuang-Fu Road, Hsinchu 30013, Taiwan; E-Mail:
| |
Collapse
|
11
|
An oil fraction neural sensor developed using electrical capacitance tomography sensor data. SENSORS 2013; 13:11385-406. [PMID: 24064598 PMCID: PMC3821372 DOI: 10.3390/s130911385] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2013] [Revised: 08/02/2013] [Accepted: 08/08/2013] [Indexed: 11/17/2022]
Abstract
This paper presents novel research on the development of a generic intelligent oil fraction sensor based on Electrical Capacitance Tomography (ECT) data. An artificial Neural Network (ANN) has been employed as the intelligent system to sense and estimate oil fractions from the cross-sections of two-component flows comprising oil and gas in a pipeline. Previous works only focused on estimating the oil fraction in the pipeline based on fixed ECT sensor parameters. With fixed ECT design sensors, an oil fraction neural sensor can be trained to deal with ECT data based on the particular sensor parameters, hence the neural sensor is not generic. This work focuses on development of a generic neural oil fraction sensor based on training a Multi-Layer Perceptron (MLP) ANN with various ECT sensor parameters. On average, the proposed oil fraction neural sensor has shown to be able to give a mean absolute error of 3.05% for various ECT sensor sizes.
Collapse
|