1
|
Carretti G, Dabraio A, Manetti M, Marini M. Biofeedback-Based Proprioceptive Training to Improve Functional Prerequisites of Dragon Boating in Breast Cancer Survivors. Eur J Investig Health Psychol Educ 2024; 14:1351-1368. [PMID: 38785587 PMCID: PMC11120340 DOI: 10.3390/ejihpe14050089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 05/09/2024] [Accepted: 05/10/2024] [Indexed: 05/25/2024] Open
Abstract
Breast cancer (BC)-related sequelae drastically impact the psychophysical functioning and quality of life of affected women. Adapted physical activity (APA) has proved to effectively counteract these impairments in a non-medicalized framework. In particular, dragon boats are able to promote body functionality, social interaction, and quality of life in BC survivors, but the literature on specific motor gestures is scarce and practice is still based more on a re-educative perspective than a performative one. In this context, the present longitudinal study investigated the benefits of an adapted biofeedback-based sensorimotor training intervention on upper body functionality in a team of dragon ladies. The 8-week intervention was conceived as integrated dry workout sessions led by an APA kinesiologist and applied a novel sensorized proprioceptive device, such as a Libra board. Post-protocol evaluation revealed a significant improvement in bilateral upper limb mobility, core endurance, and trunk stability along with a distress decrease and quality of life enhancement through validated assessment tools. Our findings suggest that integrating biofeedback-based workout sessions can effectively promote upper body functionality in BC survivors practicing dragon boating. Furthermore, our innovative approach could help spread methodological hints able to boost exercise adherence in this target population, thus counteracting cancer recurrence while promoting overall well-being.
Collapse
Affiliation(s)
| | | | | | - Mirca Marini
- Department of Experimental and Clinical Medicine, Section of Anatomy and Histology, University of Florence, 50134 Florence, Italy; (G.C.); (A.D.); (M.M.)
| |
Collapse
|
2
|
Li KJ, Wong NLY, Law MC, Lam FMH, Wong HC, Chan TO, Wong KN, Zheng YP, Huang QY, Wong AYL, Kwok TCY, Ma CZH. Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People. BIOSENSORS 2023; 13:998. [PMID: 38131758 PMCID: PMC10742152 DOI: 10.3390/bios13120998] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/31/2023] [Accepted: 11/08/2023] [Indexed: 12/23/2023]
Abstract
Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in community-dwelling older people remain unclear. Therefore, this study evaluated the performance of a commercially available IMU sensor-based fall risk assessment system among 20 community-dwelling older recurrent fallers (with a history of ≥2 falls in the past 12 months) and 20 community-dwelling older non-fallers (no history of falls in the past 12 months), together with applying the clinical scale of the Mini-Balance Evaluation Systems Test (Mini-BESTest). The results show that the IMU sensor-based system exhibited a significant moderate to excellent test-retest reliability (ICC = 0.838, p < 0.001), an acceptable level of internal consistency reliability (Spearman's rho = 0.471, p = 0.002), an acceptable convergent validity (Cronbach's α = 0.712), and an area under the curve (AUC) value of 0.590 for the IMU sensor-based receiver-operating characteristic (ROC) curve. The findings suggest that while the evaluated IMU sensor-based system exhibited good reliability and acceptable validity, it might not be able to fully identify the recurrent fallers and non-fallers in a community-dwelling older population. Further system optimization is still needed.
Collapse
Affiliation(s)
- Ke-Jing Li
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
| | - Nicky Lok-Yi Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
| | - Man-Ching Law
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China;
- Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Freddy Man-Hin Lam
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China;
| | - Hoi-Ching Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Tsz-On Chan
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Kit-Naam Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China;
- Jockey Club Smart Ageing Hub, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Qi-Yao Huang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong SAR, China;
| | - Arnold Yu-Lok Wong
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China;
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China;
| | - Timothy Chi-Yui Kwok
- Department of Medicine & Therapeutics, The Chinese University of Hong Kong, Hong Kong SAR, China;
| | - Christina Zong-Hao Ma
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China; (K.-J.L.); (N.L.-Y.W.); (M.-C.L.); (H.-C.W.); (T.-O.C.); (K.-N.W.); (Y.-P.Z.)
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR, China;
| |
Collapse
|
3
|
Tong CY, Zhu RTL, Ling YT, Scheeren EM, Lam FMH, Fu H, Ma CZH. Muscular and Kinematic Responses to Unexpected Translational Balance Perturbation: A Pilot Study in Healthy Young Adults. Bioengineering (Basel) 2023; 10:831. [PMID: 37508858 PMCID: PMC10376184 DOI: 10.3390/bioengineering10070831] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/24/2023] [Accepted: 07/03/2023] [Indexed: 07/30/2023] Open
Abstract
Falls and fall-related injuries are significant public health problems in older adults. While balance-controlling strategies have been extensively researched, there is still a lack of understanding regarding how fast the lower-limb muscles contract and coordinate in response to a sudden loss of standing balance. Therefore, this pilot study aims to investigate the speed and timing patterns of multiple joint/muscles' activities among the different challenges in standing balance. Twelve healthy young subjects were recruited, and they received unexpected translational balance perturbations with randomized intensities and directions. Electromyographical (EMG) and mechanomyographical (MMG) signals of eight dominant-leg's muscles, dominant-leg's three-dimensional (3D) hip/knee/ankle joint angles, and 3D postural sways were concurrently collected. Two-way ANOVAs were used to examine the difference in timing and speed of the collected signals among muscles/joint motions and among perturbation intensities. This study has found that (1) agonist muscles resisting the induced postural sway tended to activate more rapidly than the antagonist muscles, and ankle muscles contributed the most with the fastest rate of response; (2) voluntary corrective lower-limb joint motions and postural sways could occur as early as the perturbation-induced passive ones; (3) muscles reacted more rapidly under a larger perturbation intensity, while the joint motions or postural sways did not. These findings expand the current knowledge on standing-balance-controlling mechanisms and may potentially provide more insights for developing future fall-prevention strategies in daily life.
Collapse
Affiliation(s)
- Cheuk Ying Tong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
| | - Ringo Tang-Long Zhu
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
| | - Yan To Ling
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
- Centre for Developmental Neurobiology, King's College London, London SE1 1UL, UK
| | - Eduardo Mendonça Scheeren
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná, Curitiba 80215-901, Brazil
| | - Freddy Man Hin Lam
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
| | - Hong Fu
- Department of Mathematics and Information Technology, The Education University of Hong Kong, Hong Kong SAR 999077, China
| | - Christina Zong-Hao Ma
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
| |
Collapse
|
4
|
Wang W, Raitor M, Collins S, Liu CK, Kennedy M. Trajectory and Sway Prediction Towards Fall Prevention. IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION : ICRA : [PROCEEDINGS]. IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION 2023; 2023:10483-10489. [PMID: 38009123 PMCID: PMC10671274 DOI: 10.1109/icra48891.2023.10161361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2023]
Abstract
Falls are the leading cause of fatal and non-fatal injuries, particularly for older persons. Imbalance can result from the body's internal causes (illness), or external causes (active or passive perturbation). Active perturbation results from applying an external force to a person, while passive perturbation results from human motion interacting with a static obstacle. This work proposes a metric that allows for the monitoring of the persons torso and its correlation to active and passive perturbations. We show that large changes in the torso sway can be strongly correlated to active perturbations. We also show that we can reasonably predict the future path and expected change in torso sway by conditioning the expected path and torso sway on the past trajectory, torso motion, and the surrounding scene. This could have direct future applications to fall prevention. Results demonstrate that the torso sway is strongly correlated with perturbations. And our model is able to make use of the visual cues presented in the panorama and condition the prediction accordingly.
Collapse
Affiliation(s)
- Weizhuo Wang
- Department of Mechanical Engineering Departments, Stanford University, Stanford, CA 94305, USA
| | - Michael Raitor
- Department of Mechanical Engineering Departments, Stanford University, Stanford, CA 94305, USA
| | - Steve Collins
- Department of Mechanical Engineering Departments, Stanford University, Stanford, CA 94305, USA
| | - C Karen Liu
- Department of Computer Science Departments, Stanford University, Stanford, CA 94305, USA
| | - Monroe Kennedy
- Department of Mechanical Engineering Departments, Stanford University, Stanford, CA 94305, USA
- Department of Computer Science Departments, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
5
|
Lind CM, Abtahi F, Forsman M. Wearable Motion Capture Devices for the Prevention of Work-Related Musculoskeletal Disorders in Ergonomics-An Overview of Current Applications, Challenges, and Future Opportunities. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094259. [PMID: 37177463 PMCID: PMC10181376 DOI: 10.3390/s23094259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 04/14/2023] [Accepted: 04/22/2023] [Indexed: 05/15/2023]
Abstract
Work-related musculoskeletal disorders (WMSDs) are a major contributor to disability worldwide and substantial societal costs. The use of wearable motion capture instruments has a role in preventing WMSDs by contributing to improvements in exposure and risk assessment and potentially improved effectiveness in work technique training. Given the versatile potential for wearables, this article aims to provide an overview of their application related to the prevention of WMSDs of the trunk and upper limbs and discusses challenges for the technology to support prevention measures and future opportunities, including future research needs. The relevant literature was identified from a screening of recent systematic literature reviews and overviews, and more recent studies were identified by a literature search using the Web of Science platform. Wearable technology enables continuous measurements of multiple body segments of superior accuracy and precision compared to observational tools. The technology also enables real-time visualization of exposures, automatic analyses, and real-time feedback to the user. While miniaturization and improved usability and wearability can expand the use also to more occupational settings and increase use among occupational safety and health practitioners, several fundamental challenges remain to be resolved. The future opportunities of increased usage of wearable motion capture devices for the prevention of work-related musculoskeletal disorders may require more international collaborations for creating common standards for measurements, analyses, and exposure metrics, which can be related to epidemiologically based risk categories for work-related musculoskeletal disorders.
Collapse
Affiliation(s)
- Carl Mikael Lind
- IMM Institute of Environmental Medicine, Karolinska Institutet, 171 77 Stockholm, Sweden
| | - Farhad Abtahi
- Division of Ergonomics, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, 141 57 Huddinge, Sweden
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, 171 77 Stockholm, Sweden
- Department of Clinical Physiology, Karolinska University Hospital, 141 86 Huddinge, Sweden
| | - Mikael Forsman
- IMM Institute of Environmental Medicine, Karolinska Institutet, 171 77 Stockholm, Sweden
- Division of Ergonomics, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, 141 57 Huddinge, Sweden
- Centre for Occupational and Environmental Medicine, Stockholm County Council, 113 65 Stockholm, Sweden
| |
Collapse
|
6
|
Lim HJ, Lai DKH, So BPH, Yip CCK, Cheung DSK, Cheung JCW, Wong DWC. A Comprehensive Assessment Protocol for Swallowing (CAPS): Paving the Way towards Computer-Aided Dysphagia Screening. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:2998. [PMID: 36833691 PMCID: PMC9963613 DOI: 10.3390/ijerph20042998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 02/04/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Dysphagia is one of the most common problems among older adults, which might lead to aspiration pneumonia and eventual death. It calls for a feasible, reliable, and standardized screening or assessment method to prompt rehabilitation measures and mitigate the risks of dysphagia complications. Computer-aided screening using wearable technology could be the solution to the problem but is not clinically applicable because of the heterogeneity of assessment protocols. The aim of this paper is to formulate and unify a swallowing assessment protocol, named the Comprehensive Assessment Protocol for Swallowing (CAPS), by integrating existing protocols and standards. The protocol consists of two phases: the pre-test phase and the assessment phase. The pre-testing phase involves applying different texture or thickness levels of food/liquid and determining the required bolus volume for the subsequent assessment. The assessment phase involves dry (saliva) swallowing, wet swallowing of different food/liquid consistencies, and non-swallowing (e.g., yawning, coughing, speaking, etc.). The protocol is designed to train the swallowing/non-swallowing event classification that facilitates future long-term continuous monitoring and paves the way towards continuous dysphagia screening.
Collapse
Affiliation(s)
- Hyo-Jung Lim
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Derek Ka-Hei Lai
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Bryan Pak-Hei So
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | | | - Daphne Sze Ki Cheung
- School of Nursing, The Hong Kong Polytechnic University, Hong Kong, China
- Research Institute of Smart Ageing, The Hong Kong Polytechnic University, Hong Kong, China
| | - James Chung-Wai Cheung
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
- Research Institute of Smart Ageing, The Hong Kong Polytechnic University, Hong Kong, China
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
7
|
X-reality for Phantom Limb Management for Amputees: A Systematic Review and Meta-Analysis. ENGINEERED REGENERATION 2023. [DOI: 10.1016/j.engreg.2023.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
|
8
|
The effect of mobile application-based rehabilitation in patients with Parkinson's disease: A systematic review and meta-analysis. Clin Neurol Neurosurg 2023; 225:107579. [PMID: 36603336 DOI: 10.1016/j.clineuro.2022.107579] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 12/04/2022] [Accepted: 12/26/2022] [Indexed: 12/29/2022]
Abstract
OBJECTIVE Mobile app-based telerehabilitation is practical and cost-effective in neurological rehabilitation. The present systematic review aimed to investigate the effectiveness of mobile application-based rehabilitation in patients with Parkinson's Disease. METHODS Literature was searched via databases of "Web of Science (WoS), PubMed, Cochrane, Scopus and ScienceDirect". Physiotherapy Evidence Database (PEDro) and Revised Cochrane risk-of-bias tool for randomized trials (RoB2) were used to evaluate the quality analysis and risk of bias evaluation. Both narrative and quantitative synthesis were carried out. RESULTS A total of 2175 articles were screened (WoS=41, PubMed=42, Cochrane=84, Scopus=114, ScienceDirect=1894). A total of 5 studies were included in the systematic review following the screening and eligibility procedures. Two studies were enrolled in meta-analysis regarding the data homogeneity. PEDro scores of the trials ranged from 4 to 7 (median:6), indicating good quality. All studies were in the "some concerns" category. The mobile application-based intervention yielded better results on quality of life and patient adherence in two studies. Application-based rehabilitation was not superior to standard treatment on MiniBESTest (ES:0.15, 95 % CI: -0.33 to 0.26) and UPDRS III (ES:0.86, 95 % CI: -0.94 to 2.46) scores. CONCLUSION Mobile application-based rehabilitation is not superior to standard treatments in balance and disease severity. However, mobile technologies could be preferred to increase patient adherence and quality of life. The limited study and the low number of cases in the review may reduce the level of evidence for the results.
Collapse
|
9
|
Ng G, Andrysek J. Classifying Changes in Amputee Gait following Physiotherapy Using Machine Learning and Continuous Inertial Sensor Signals. SENSORS (BASEL, SWITZERLAND) 2023; 23:1412. [PMID: 36772451 PMCID: PMC9921298 DOI: 10.3390/s23031412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/13/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
Wearable sensors allow for the objective analysis of gait and motion both in and outside the clinical setting. However, it remains a challenge to apply such systems to highly diverse patient populations, including individuals with lower-limb amputations (LLA) that present with unique gait deviations and rehabilitation goals. This paper presents the development of a novel method using continuous gyroscope data from a single inertial sensor for person-specific classification of gait changes from a physiotherapist-led gait training session. Gyroscope data at the thigh were collected using a wearable gait analysis system for five LLA before, during, and after completing a gait training session. Data from able-bodied participants receiving no intervention were also collected. Models using dynamic time warping (DTW) and Euclidean distance in combination with the nearest neighbor classifier were applied to the gyroscope data to classify the pre- and post-training gait. The model achieved an accuracy of 98.65% ± 0.69 (Euclidean) and 98.98% ± 0.83 (DTW) on pre-training and 95.45% ± 6.20 (Euclidean) and 94.18% ± 5.77 (DTW) on post-training data across the participants whose gait changed significantly during their session. This study provides preliminary evidence that continuous angular velocity data from a single gyroscope could be used to assess changes in amputee gait. This supports future research and the development of wearable gait analysis and feedback systems that are adaptable to a broad range of mobility impairments.
Collapse
Affiliation(s)
- Gabriel Ng
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 1A1, Canada
- Bloorview Research Institute (BRI), Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada
| | - Jan Andrysek
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 1A1, Canada
- Bloorview Research Institute (BRI), Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada
| |
Collapse
|
10
|
Park C, Mishra RK, York MK, Enriquez A, Lindsay A, Barchard G, Vaziri A, Najafi B. Tele-Medicine Based and Self-Administered Interactive Exercise Program (Tele-Exergame) to Improve Cognition in Older Adults with Mild Cognitive Impairment or Dementia: A Feasibility, Acceptability, and Proof-of-Concept Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:16361. [PMID: 36498431 PMCID: PMC9739527 DOI: 10.3390/ijerph192316361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 11/27/2022] [Accepted: 12/03/2022] [Indexed: 06/17/2023]
Abstract
Improved life expectancy is increasing the number of older adults who suffer from motor-cognitive decline. Unfortunately, conventional balance exercise programs are not tailored to patients with cognitive impairments, and exercise adherence is often poor due to unsupervised settings. This study describes the acceptability and feasibility of a sensor-based in-home interactive exercise system, called tele-Exergame, used by older adults with mild cognitive impairment (MCI) or dementia. Our tele-Exergame is specifically designed to improve balance and cognition during distractive conditioning while a telemedicine interface remotely supervises the exercise, and its exercises are gamified balance tasks with explicit augmented visual feedback. Fourteen adults with MCI or dementia (Age = 68.1 ± 5.4 years, 12 females) participated and completed exergame twice weekly for six weeks at their homes. Before and after 6 weeks, participants' acceptance was assessed by Technology Acceptance Model (TAM) questionnaire, and participants' cognition and anxiety level were evaluated by the Montreal Cognitive Assessment (MoCA) and Beck Anxiety Inventory (BAI), respectively. Results support acceptability, perceived benefits, and positive attitudes toward the use of the system. The findings of this study support the feasibility, acceptability, and potential benefit of tele-Exergame to preserve cognitive function among older adults with MCI and dementia.
Collapse
Affiliation(s)
- Catherine Park
- Interdisciplinary Consortium on Advanced Motion Performance (iCAMP), Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX 77030, USA
- VA’s Health Services Research and Development Service (HSR&D), Center for Innovations in Quality, Effectiveness, and Safety, Michael E. DeBakey VA Medical Center, Houston, TX 77030, USA
- Big Data Scientist Training Enhancement Program, VA Office of Research and Development, Washington, DC 20420, USA
| | - Ram kinker Mishra
- Interdisciplinary Consortium on Advanced Motion Performance (iCAMP), Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX 77030, USA
- The BioSensics LLC, Newton, MA 02458, USA
| | - Michele K. York
- Neurology and Psychiatry & Behavioral Sciences, Baylor College of Medicine, Houston, TX 77030, USA
| | | | | | | | | | - Bijan Najafi
- Interdisciplinary Consortium on Advanced Motion Performance (iCAMP), Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, TX 77030, USA
| |
Collapse
|
11
|
Kourtesis P, Argelaguet F, Vizcay S, Marchal M, Pacchierotti C. Electrotactile Feedback Applications for Hand and Arm Interactions: A Systematic Review, Meta-Analysis, and Future Directions. IEEE TRANSACTIONS ON HAPTICS 2022; 15:479-496. [PMID: 35816531 DOI: 10.1109/toh.2022.3189866] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Haptic feedback is critical in a broad range of human-machine/computer-interaction applications. However, the high cost and low portability/wearability of haptic devices remain unresolved issues, severely limiting the adoption of this otherwise promising technology. Electrotactile interfaces have the advantage of being more portable and wearable due to their reduced actuators' size, as well as their lower power consumption and manufacturing cost. The applications of electrotactile feedback have been explored in human-computer interaction and human-machine-interaction for facilitating hand-based interactions in applications, such as prosthetics, virtual reality, robotic teleoperation, surface haptics, portable devices, and rehabilitation. This article presents a technological overview of electrotactile feedback, as well a systematic review and meta-analysis of its applications for hand-based interactions. We discuss the different electrotactile systems according to the type of application. We also discuss over a quantitative congregation of the findings, to offer a high-level overview into the state-of-art and suggest future directions. Electrotactile feedback systems showed increased portability/wearability, and they were successful in rendering and/or augmenting most tactile sensations, eliciting perceptual processes, and improving performance in many scenarios. However, knowledge gaps (e.g., embodiment), technical (e.g., recurrent calibration, electrodes' durability) and methodological (e.g., sample size) drawbacks were detected, which should be addressed in future studies.
Collapse
|
12
|
Mate KKV, Abou-Sharkh A, Mansoubi M, Alosaimi A, Dawes H, Michael W, Stanwood O, Harding S, Gorenko D, Mayo NE. Evidence for efficacy of commercially available wearable biofeedback gait devices: a consumer-centered review (Preprint). JMIR Rehabil Assist Technol 2022; 10:e40680. [PMID: 37074771 PMCID: PMC10157455 DOI: 10.2196/40680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 12/19/2022] [Accepted: 02/26/2023] [Indexed: 02/27/2023] Open
Abstract
BACKGROUND The number of wearable technological devices or sensors that are commercially available for gait training is increasing. These devices can fill a gap by extending therapy outside the clinical setting. This was shown to be important during the COVID-19 pandemic when people could not access one-on-one treatment. These devices vary widely in terms of mechanisms of therapeutic effect, as well as targeted gait parameters, availability, and strength of the evidence supporting the claims. OBJECTIVE This study aimed to create an inventory of devices targeting improvement in gait pattern and walking behavior and identify the strength of the evidence underlying the claims of effectiveness for devices that are commercially available to the public. METHODS As there is no systematic or reproducible way to identify gait training technologies available to the public, we used a pragmatic, iterative approach using both the gray and published literature. Four approaches were used: simple words, including some suggested by laypersons; devices endorsed by condition-specific organizations or charities; impairment-specific search terms; and systematic reviews. A findable list of technological devices targeting walking was extracted separately by 3 authors. For each device identified, the evidence for efficacy was extracted from material displayed on the websites, and full-text articles were obtained from the scientific databases PubMed, Ovid MEDLINE, Scopus, or Google Scholar. Additional information on the target population, mechanism of feedback, evidence for efficacy or effectiveness, and commercial availability was obtained from the published material or websites. A level of evidence was assigned to each study involving the device using the Oxford Centre for Evidence-Based Medicine classification. We also proposed reporting guidelines for the clinical appraisal of devices targeting movement and mobility. RESULTS The search strategy for this consumer-centered review yielded 17 biofeedback devices that claim to target gait quality improvement through various sensory feedback mechanisms. Of these 17 devices, 11 (65%) are commercially available, and 6 (35%) are at various stages of research and development. Of the 11 commercially available devices, 4 (36%) had findable evidence for efficacy potential supporting the claims. Most of these devices were targeted to people living with Parkinson disease. The reporting of key information about the devices was inconsistent; in addition, there was no summary of research findings in layperson's language. CONCLUSIONS The amount of information that is currently available to the general public to help them make an informed choice is insufficient, and, at times, the information presented is misleading. The evidence supporting the effectiveness does not cover all aspects of technology uptake. Commercially available technologies help to provide continuity of therapy outside the clinical setting, but there is a need to demonstrate effectiveness to support claims made by the technologies.
Collapse
Affiliation(s)
- Kedar K V Mate
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Ahmed Abou-Sharkh
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Maedeh Mansoubi
- Medical School, University of Exeter, Exeter, United Kingdom
| | - Aeshah Alosaimi
- King Faisal Specialized Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Helen Dawes
- Medical School, University of Exeter, Exeter, United Kingdom
| | - Wright Michael
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Olivia Stanwood
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Sarah Harding
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Daniel Gorenko
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Nancy E Mayo
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| |
Collapse
|
13
|
Ma CZH, Bao T, DiCesare CA, Harris I, Chambers A, Shull PB, Zheng YP, Cham R, Sienko KH. Reducing Slip Risk: A Feasibility Study of Gait Training with Semi-Real-Time Feedback of Foot-Floor Contact Angle. SENSORS (BASEL, SWITZERLAND) 2022; 22:3641. [PMID: 35632054 PMCID: PMC9144019 DOI: 10.3390/s22103641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/30/2022] [Accepted: 05/02/2022] [Indexed: 11/16/2022]
Abstract
Slip-induced falls, responsible for approximately 40% of falls, can lead to severe injuries and in extreme cases, death. A large foot-floor contact angle (FFCA) during the heel-strike event has been associated with an increased risk of slip-induced falls. The goals of this feasibility study were to design and assess a method for detecting FFCA and providing cues to the user to generate a compensatory FFCA response during a future heel-strike event. The long-term goal of this research is to train gait in order to minimize the likelihood of a slip event due to a large FFCA. An inertial measurement unit (IMU) was used to estimate FFCA, and a speaker provided auditory semi-real-time feedback when the FFCA was outside of a 10-20 degree target range following a heel-strike event. In addition to training with the FFCA feedback during a 10-min treadmill training period, the healthy young participants completed pre- and post-training overground walking trials. Results showed that training with FFCA feedback increased FFCA events within the target range by 16% for "high-risk" walkers (i.e., participants that walked with more than 75% of their FFCAs outside the target range) both during feedback treadmill trials and post-training overground trials without feedback, supporting the feasibility of training FFCA using a semi-real-time FFCA feedback system.
Collapse
Affiliation(s)
- Christina Zong-Hao Ma
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (C.Z.-H.M.); (T.B.); (C.A.D.); (I.H.)
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China;
| | - Tian Bao
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (C.Z.-H.M.); (T.B.); (C.A.D.); (I.H.)
| | - Christopher A. DiCesare
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (C.Z.-H.M.); (T.B.); (C.A.D.); (I.H.)
| | - Isaac Harris
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (C.Z.-H.M.); (T.B.); (C.A.D.); (I.H.)
| | - April Chambers
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15260, USA; (A.C.); (R.C.)
- Department of Health and Human Development, University of Pittsburgh, Pittsburgh, PA 15260, USA
| | - Peter B. Shull
- Department of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China;
| | - Rakie Cham
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15260, USA; (A.C.); (R.C.)
| | - Kathleen H. Sienko
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (C.Z.-H.M.); (T.B.); (C.A.D.); (I.H.)
| |
Collapse
|
14
|
Clinical and Radiographic Outcome of Non-Surgical Endodontic Treatment Using Calcium Silicate-Based Versus Resin-Based Sealers-A Systematic Review and Meta-Analysis of Clinical Studies. J Funct Biomater 2022; 13:jfb13020038. [PMID: 35466220 PMCID: PMC9036224 DOI: 10.3390/jfb13020038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/02/2022] [Accepted: 04/06/2022] [Indexed: 12/10/2022] Open
Abstract
The aim of this paper is to systematically analyse the effect of calcium silicate-based sealers in comparison to resin-based sealers on clinical and radiographic outcomes of non-surgical endodontic treatment in permanent teeth. Methods: The study was conducted according to the guidelines of the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statement. The literature search was performed using PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, DOAJ and OpenGrey with no language restrictions. Two reviewers critically assessed the studies for eligibility. Grading of Recommendations, Assessment, Development and Evaluations (GRADE) was carried out to assess the evidence. Meta-analysis of the pooled data with subgroups was carried out using the RevMan software (p < 0.05). Results: Results from the included studies showed that there were no significant differences between the groups in the 24 h post-obturation pain levels (mean difference (MD), −0.19, 95% CI = −0.43−0.06, p = 0.14, I2 = 0%), but at 48 h (MD, −0.35, 95% CI = −0.64−0.05, p = 0.02, I2 = 0%), a significant difference was observed in favour of calcium silicate sealers. Furthermore, there were no significant differences between the two sealers due to risk of onset or intensity of postoperative pain, need for analgesic and extrusion of the sealer. The heterogeneity assessed using Q test between the included studies was 97% (I2). Conclusions: Within the limitations of this review, the paper shows that calcium silicate-based sealers exhibited optimal performance with similar results to resin-based sealers in terms of average level of post-obturation pain, risk of onset and pain intensity at 24 and 48 h. The observations from the included studies are informative in the clinical evaluation of calcium silicate-based sealers and provide evidence for the conduction of well-designed, controlled randomised clinical trials for a period of at least four years in the future.
Collapse
|
15
|
Utility of the Novel MediPost Mobile Posturography Device in the Assessment of Patients with a Unilateral Vestibular Disorder. SENSORS 2022; 22:s22062208. [PMID: 35336379 PMCID: PMC8953915 DOI: 10.3390/s22062208] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/02/2022] [Accepted: 03/10/2022] [Indexed: 12/28/2022]
Abstract
Balance disorders are a growing problem worldwide. Thus, there is an increasing need to provide an inexpensive and feasible alternative to standard posturographic platforms (SP) used for the assessment of balance and to provide a possible solution for telemonitoring of patients. A novel mobile posturography (MP) MediPost device was developed to address these issues. This prospective study used a Modified Clinical Test of Sensory Interaction on Balance to evaluate healthy individuals and patients with a unilateral vestibular disorder through SP and MP simultaneously. The control group included 65 healthy volunteers, while the study group included 38 patients diagnosed with a unilateral vestibular deficit. The angular velocity values obtained from both methods were compared by intraclass correlation coefficients (ICC) and Bland−Altman plot analysis. Diagnostic capabilities were measured in terms of sensitivity and specificity. The ICC between the two methods for conditions 2−4 was indicative of excellent reliability, with the ICC > 0.9 (p < 0.001), except for Condition 1 (standing stance, eyes open) ICC = 0.685, p < 0.001, which is indicative of moderate reliability. ROC curve analysis of angular velocity for condition 4 represents the most accurate differentiating factor with AUC values of 0.939 for SP and 0.953 for MP. This condition also reported the highest sensitivity, specificity, PPV, and NPV values with 86.4%, 87.7%, 80%, and 90.5% for SP, and 92.1%, 84.6%, 77.8%, and 94.8% for MP, respectively. The newly developed MediPost device has high sensitivity and specificity in distinguishing between healthy individuals and patients with a unilateral vestibular deficit.
Collapse
|
16
|
Kantan P, Spaich EG, Dahl S. An Embodied Sonification Model for Sit-to-Stand Transfers. Front Psychol 2022; 13:806861. [PMID: 35250738 PMCID: PMC8891127 DOI: 10.3389/fpsyg.2022.806861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 01/25/2022] [Indexed: 11/13/2022] Open
Abstract
Interactive sonification of biomechanical quantities is gaining relevance as a motor learning aid in movement rehabilitation, as well as a monitoring tool. However, existing gaps in sonification research (issues related to meaning, aesthetics, and clinical effects) have prevented its widespread recognition and adoption in such applications. The incorporation of embodied principles and musical structures in sonification design has gradually become popular, particularly in applications related to human movement. In this study, we propose a general sonification model for the sit-to-stand (STS) transfer, an important activity of daily living. The model contains a fixed component independent of the use-case, which represents the rising motion of the body as an ascending melody using the physical model of a flute. In addition, a flexible component concurrently sonifies STS features of clinical interest in a particular rehabilitative/monitoring situation. Here, we chose to represent shank angular jerk and movement stoppages (freezes), through perceptually salient pitch modulations and bell sounds. We outline the details of our technical implementation of the model. We evaluated the model by means of a listening test experiment with 25 healthy participants, who were asked to identify six normal and simulated impaired STS patterns from sonified versions containing various combinations of the constituent mappings of the model. Overall, we found that the participants were able to classify the patterns accurately (86.67 ± 14.69% correct responses with the full model, 71.56% overall), confidently (64.95 ± 16.52% self-reported rating), and in a timely manner (response time: 4.28 ± 1.52 s). The amount of sonified kinematic information significantly impacted classification accuracy. The six STS patterns were also classified with significantly different accuracy depending on their kinematic characteristics. Learning effects were seen in the form of increased accuracy and confidence with repeated exposure to the sound sequences. We found no significant accuracy differences based on the participants' level of music training. Overall, we see our model as a concrete conceptual and technical starting point for STS sonification design catering to rehabilitative and clinical monitoring applications.
Collapse
Affiliation(s)
- Prithvi Kantan
- Department of Architecture, Design and Media Technology, Aalborg University, Copenhagen, Denmark
| | - Erika G Spaich
- Neurorehabilitation Systems Group, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Sofia Dahl
- Department of Architecture, Design and Media Technology, Aalborg University, Copenhagen, Denmark
| |
Collapse
|
17
|
Salchow-Hömmen C, Skrobot M, Jochner MCE, Schauer T, Kühn AA, Wenger N. Review-Emerging Portable Technologies for Gait Analysis in Neurological Disorders. Front Hum Neurosci 2022; 16:768575. [PMID: 35185496 PMCID: PMC8850274 DOI: 10.3389/fnhum.2022.768575] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 01/07/2022] [Indexed: 01/29/2023] Open
Abstract
The understanding of locomotion in neurological disorders requires technologies for quantitative gait analysis. Numerous modalities are available today to objectively capture spatiotemporal gait and postural control features. Nevertheless, many obstacles prevent the application of these technologies to their full potential in neurological research and especially clinical practice. These include the required expert knowledge, time for data collection, and missing standards for data analysis and reporting. Here, we provide a technological review of wearable and vision-based portable motion analysis tools that emerged in the last decade with recent applications in neurological disorders such as Parkinson's disease and Multiple Sclerosis. The goal is to enable the reader to understand the available technologies with their individual strengths and limitations in order to make an informed decision for own investigations and clinical applications. We foresee that ongoing developments toward user-friendly automated devices will allow for closed-loop applications, long-term monitoring, and telemedical consulting in real-life environments.
Collapse
Affiliation(s)
- Christina Salchow-Hömmen
- Department of Neurology With Experimental Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Matej Skrobot
- Department of Neurology With Experimental Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Magdalena C E Jochner
- Department of Neurology With Experimental Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Thomas Schauer
- Control Systems Group, Technische Universität Berlin, Berlin, Germany
| | - Andrea A Kühn
- Department of Neurology With Experimental Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany
- Berlin School of Mind and Brain, Charité-Universitätsmedizin Berlin, Berlin, Germany
- NeuroCure Clinical Research Centre, Charité-Universitätsmedizin Berlin, Berlin, Germany
- German Center for Neurodegenerative Diseases, DZNE, Berlin, Germany
| | - Nikolaus Wenger
- Department of Neurology With Experimental Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
18
|
Warrington DJ, Shortis EJ, Whittaker PJ. Are wearable devices effective for preventing and detecting falls: an umbrella review (a review of systematic reviews). BMC Public Health 2021; 21:2091. [PMID: 34775947 PMCID: PMC8591794 DOI: 10.1186/s12889-021-12169-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 10/26/2021] [Indexed: 01/08/2023] Open
Abstract
Background Falls are a common and serious health issue facing the global population, causing an estimated 646,000 deaths per year globally. Wearable devices typically combine accelerometers, gyroscopes and even barometers; using the data collected and inputting this into an algorithm that decides whether a fall has occurred. The purpose of this umbrella review was to provide a comprehensive overview of the systematic reviews on the effectiveness of wearable electronic devices for falls detection in adults. Methods MEDLINE, Embase, Cochrane Database of Systematic Reviews (CDSR), and CINAHL, were searched from their inceptions until April 2019 for systematic reviews that assessed the accuracy of wearable technology in the detection of falls. Results Seven systematic reviews were included in this review. Due to heterogeneity between the included systematic reviews in their methods and their reporting of results, a meta-analysis could not be performed. Most devices tested used accelerometers, often in combination with gyroscopes. Three systematic reviews reported an average sensitivity of 93.1% or greater and an average specificity of 86.4% or greater for the detection of falls. Placing sensors on the trunk, foot or leg appears to provide the highest accuracy for falls detection, with multiple sensors increasing the accuracy, specificity, and sensitivity of these devices. Conclusions This review demonstrated that wearable device technology offers a low-cost and accurate way to effectively detect falls and summon for help. There are significant differences in the effectiveness of these devices depending on the type of device and its placement. Further high-quality research is needed to confirm the accuracy of these devices in frail older people in real-world settings.
Collapse
Affiliation(s)
- Daniel Joseph Warrington
- Division of Population Health, Health Services Research & Primary Care, Faculty of Biology, Medicine and Health, University of Manchester, Room 2.545, Stopford Building, Oxford Road, Manchester, M13 9PT, UK.
| | - Elizabeth Jane Shortis
- Division of Population Health, Health Services Research & Primary Care, Faculty of Biology, Medicine and Health, University of Manchester, Room 2.545, Stopford Building, Oxford Road, Manchester, M13 9PT, UK
| | - Paula Jane Whittaker
- Division of Population Health, Health Services Research & Primary Care, Faculty of Biology, Medicine and Health, University of Manchester, Room 2.545, Stopford Building, Oxford Road, Manchester, M13 9PT, UK
| |
Collapse
|
19
|
Chen L, Feng Y, Chen B, Wang Q, Wei K. Improving postural stability among people with lower-limb amputations by tactile sensory substitution. J Neuroeng Rehabil 2021; 18:159. [PMID: 34742292 PMCID: PMC8572471 DOI: 10.1186/s12984-021-00952-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 10/19/2021] [Indexed: 01/12/2023] Open
Abstract
Background For people with lower-limb amputations, wearing a prosthetic limb helps restore their motor abilities for daily activities. However, the prosthesis's potential benefits are hindered by limited somatosensory feedback from the affected limb and its prosthesis. Previous studies have examined various sensory substitution systems to alleviate this problem; the prominent approach is to convert foot–ground interaction to tactile stimulations. However, positive outcomes for improving their postural stability are still rare. We hypothesized that the sensory substiution system based on surrogated tactile stimulus is capable of improving the standing stability among people with lower-limb amputations. Methods We designed a wearable device consisting of four pressure sensors and two vibrators and tested it among people with unilateral transtibial amputations (n = 7) and non-disabled participants (n = 8). The real-time measurements of foot pressure were fused into a single representation of foot–ground interaction force, which was encoded by varying vibration intensity of the two vibrators attached to the participants’ forearm. The vibration intensity followed a logarithmic function of the force representation, in keeping with principles of tactile psychophysics. The participants were tested with a classical postural stability task in which visual disturbances perturbed their quiet standing. Results With a brief familiarization of the system, the participants exhibited better postural stability against visual disturbances when switching on sensory substitution than without. The body sway was substantially reduced, as shown in head movements and excursions of the center of pressure. The improvement was present for both groups of participants and was particularly pronounced in more challenging conditions with larger visual disturbances. Conclusions Substituting otherwise missing foot pressure feedback with vibrotactile signals can improve postural stability for people with lower-limb amputations. The design of the mapping between the foot–ground interaction force and the tactile signals is essential for the user to utilize the surrogated tactile signals for postural control, especially for situations that their postural control is challenged.
Collapse
Affiliation(s)
- Lijun Chen
- School of Psychological and Cognitive Sciences, Peking University, 5 Yiheyuan Road, 100871, Beijing, China.,Beijing Key Laboratory of Behavior and Mental Health, Beijing, China
| | - Yanggang Feng
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing, China
| | - Baojun Chen
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing, China
| | - Qining Wang
- Department of Advanced Manufacturing and Robotics, College of Engineering, Peking University, Beijing, China
| | - Kunlin Wei
- School of Psychological and Cognitive Sciences, Peking University, 5 Yiheyuan Road, 100871, Beijing, China. .,Beijing Key Laboratory of Behavior and Mental Health, Beijing, China. .,Key Laboratory of Machine Perception, Ministry of Education, Beijing, China. .,Peking-Tsinghua Center for Life Sciences, Beijing, China.
| |
Collapse
|
20
|
Tannert I, Schulleri KH, Michel Y, Villa S, Johannsen L, Hermsdorfer J, Lee D. Immediate Effects of Vibrotactile Biofeedback Instructions on Human Postural Control. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:7426-7432. [PMID: 34892813 DOI: 10.1109/embc46164.2021.9630992] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Vibrotactile biofeedback can improve balance and consequently be helpful in fall prevention. However, it remains unclear how different types of stimulus presentations affect not only trunk tilt, but also Center of Pressure (CoP) displacements, and whether an instruction on how to move contributes to a better understanding of vibrotactile feedback.Based on lower back tilt angles (L5), we applied individualized multi-directional vibrotactile feedback to the upper torso by a haptic vest in 30 healthy young adults. Subjects were equally distributed to three instruction groups (attractive - move in the direction of feedback, repulsive - move in the opposite direction of feedback & no instruction - with attractive stimuli). We conducted four conditions with eyes closed (feedback on/off, Narrow Stance with head extended, Semi-Tandem stance), with seven trials of 45s each. For CoP and L5, we computed Root Mean Square (RMS) of position/angle and standard deviation (SD) of velocity, and for L5 additionally, the percentage in time above threshold. The analysis consisted of mixed model ANOVAs and t-tests (α-level: 0.05).In the attractive and repulsive groups feedback significantly decreased the percentage above threshold (p<0.05). Feedback decreased RMS of L5, whereas RMS of CoP and SD of velocity in L5 and COP increased (p<0.05). Finally, an instruction on how to move contributed to a better understanding of the vibrotactile biofeedback.
Collapse
|
21
|
Hessfeld V, Schulleri KH, Lee D. Assessment of Balance Instability by Wearable Sensor Systems During Postural Transitions. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:7455-7459. [PMID: 34892273 DOI: 10.1109/embc46164.2021.9631072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Several studies have demonstrated beneficial effects of real-time biofeedback for improving postural control. However, the application for daily activities, which also include postural transitions, is still limited. One crucial aspect is the time point of providing feedback, and thus its reliability. This might depend on the sensor system used, but also on how the threshold is defined. This study investigates which wearable sensor system and what kind of threshold is more reliable in a situation of a postural transition.To this end, we compared three sensor systems regarding their accuracy in timing in a stable and unstable postural transition in 16 healthy young adults: a multiple Inertial Measurement Unit system (IMU), a pressure Insoles System (IS), and a combination of both systems (COMB). Further, we contrasted two threshold parameters for each system: a Quiet Standing-based threshold (QSth) and a Limits of Stability-based threshold (LoSth).Two-way repeated measures ANOVAs and Wilcoxon tests (α = 0.05) indicated highest accuracy in the COMB LoSth, though with small differences to the IS LoSth. The LoSth showed more accurate timing than the QSth, especially in medio-lateral direction for IS and COMB.Consequently, for providing a reliable timing for a potential biofeedback applied by a wearable device in everyday life situations applications should focus on pressure insoles and a functional stability threshold, such as the LoS-based threshold.
Collapse
|
22
|
Oubre B, Lane S, Holmes S, Boyer K, Lee SI. Estimating Ground Reaction Force and Center of Pressure using Low-Cost Wearable Devices. IEEE Trans Biomed Eng 2021; 69:1461-1468. [PMID: 34648428 DOI: 10.1109/tbme.2021.3120346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Ambulatory monitoring of ground reaction force (GRF) and center of pressure (CoP) could improve management of health conditions that impair mobility. Insoles instrumented with force-sensitive resistors (FSRs) are an unobtrusive, low-cost, and low-power technology for sampling GRF and CoP in real-world environments. However, FSRs have variable response characteristics that complicate estimation of GRF and CoP. This study introduces a unique data analytic pipeline that enables accurate estimation of GRF and CoP despite relatively inaccurate FSR responses. This paper also investigates whether inclusion of a complementary knee angle sensor improves estimation accuracy. METHODS Seventeen healthy subjects were equipped with an insole instrumented with six FSRs and a string-based knee angle sensor. Subjects walked in a straight line at self-selected slow, preferred, and fast speeds over an in-ground force platform. Twenty repetitions were performed for each speed. Supervised machine learning models estimated weight-normalized GRF and shoe size-normalized CoP, which were re-scaled to obtain GRF and CoP. RESULTS Anteroposterior GRF, Vertical GRF, and Anteroposterior CoP were estimated with a normalized root mean square error (NRMSE) of less than 5%. Mediolateral GRF and CoP were estimated with an NRMSE of 8.1% and 6.4%$ respectively. Knee angle-related features slightly improved GRF estimates. CONCLUSION Normalized models accurately estimated GRF and CoP despite deficiencies in FSR data. SIGNIFICANCE Ambulatory use of the proposed system could enable objective, longitudinal monitoring of severity and progression for a variety of health conditions.
Collapse
|
23
|
Lee R, James C, Edwards S, Skinner G, Young JL, Snodgrass SJ. Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:6377. [PMID: 34640695 PMCID: PMC8512480 DOI: 10.3390/s21196377] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 09/16/2021] [Accepted: 09/18/2021] [Indexed: 01/03/2023]
Abstract
Background: Wearable inertial sensor technology (WIST) systems provide feedback, aiming to modify aberrant postures and movements. The literature on the effects of feedback from WIST during work or work-related activities has not been previously summarised. This review examines the effectiveness of feedback on upper body kinematics during work or work-related activities, along with the wearability and a quantification of the kinematics of the related device. Methods: The Cinahl, Cochrane, Embase, Medline, Scopus, Sportdiscus and Google Scholar databases were searched, including reports from January 2005 to July 2021. The included studies were summarised descriptively and the evidence was assessed. Results: Fourteen included studies demonstrated a 'limited' level of evidence supporting posture and/or movement behaviour improvements using WIST feedback, with no improvements in pain. One study assessed wearability and another two investigated comfort. Studies used tri-axial accelerometers or IMU integration (n = 5 studies). Visual and/or vibrotactile feedback was mostly used. Most studies had a risk of bias, lacked detail for methodological reproducibility and displayed inconsistent reporting of sensor technology, with validation provided only in one study. Thus, we have proposed a minimum 'Technology and Design Checklist' for reporting. Conclusions: Our findings suggest that WIST may improve posture, though not pain; however, the quality of the studies limits the strength of this conclusion. Wearability evaluations are needed for the translation of WIST outcomes. Minimum reporting standards for WIST should be followed to ensure methodological reproducibility.
Collapse
Affiliation(s)
- Roger Lee
- School of Health Sciences, The University of Newcastle, Newcastle 2308, Australia; (C.J.); (S.J.S.)
- Centre for Brain and Mental Health Research, The University of Newcastle, Newcastle 2308, Australia
| | - Carole James
- School of Health Sciences, The University of Newcastle, Newcastle 2308, Australia; (C.J.); (S.J.S.)
- Centre for Resources Health and Safety, The University of Newcastle, Newcastle 2308, Australia
| | - Suzi Edwards
- School of Health Sciences, The University of Sydney, Sydney 2006, Australia;
| | - Geoff Skinner
- School of Information and Physical Sciences, The University of Newcastle, Newcastle 2308, Australia;
| | - Jodi L. Young
- Department of Physical Therapy, Bellin College, Green Bay, WI 54311, USA;
| | - Suzanne J. Snodgrass
- School of Health Sciences, The University of Newcastle, Newcastle 2308, Australia; (C.J.); (S.J.S.)
- Centre for Brain and Mental Health Research, The University of Newcastle, Newcastle 2308, Australia
| |
Collapse
|
24
|
Wrisley DM, McLean G, Hill JB, Oddsson LIE. Long-Term Use of a Sensory Prosthesis Improves Function in a Patient With Peripheral Neuropathy: A Case Report. Front Neurol 2021; 12:655963. [PMID: 34248817 PMCID: PMC8260940 DOI: 10.3389/fneur.2021.655963] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/27/2021] [Indexed: 12/25/2022] Open
Abstract
Background: Peripheral neuropathy (PN) can result in either partial or complete loss of distal sensation resulting in an increased fall risk. Walkasins® uses a shoe insert to detect the magnitude and direction of sway and sends signals to a leg unit that provides sensory balance cues. The objective of this case report is to describe the long-term influence of the Walkasins® lower limb sensory neuroprosthesis on balance and gait for an individual with diabetic PN. Case Description: A 51-year-old male with a 3-year history of PN and a 10-year history of type II diabetes mellitus was fitted bilaterally with Walkasins® and utilized them 8-10 hours/day for more than 2 years. Although, vibration and tactile sensation thresholds were severely impaired at his 1st metatarsophalangeal joint and the lateral malleolus bilaterally he could perceive tactile stimuli from the Walkasins® above the ankles. Outcomes: Following Walkasins® use, his Activities-specific Balance Confidence Scale (ABC) scores improved from 33 to 80%. His mean Vestibular Activities of Daily Living (VADL) scores decreased from 3.54 to 1. His Functional Gait Assessment (FGA) scores increased from 13/30 to 28/30 and his miniBESTest scores improved from 15/28 to 26/28. Gait speed increased from 0.23 to 1.5 m/s. The patient described a decrease in pain and cramping throughout his lower extremities and an increase in function. Discussion: Gait and balance improved with the use of the Walkasins® and participation in a wellness program. This improvement suggests that the use of sensory substitution devices, such as the Walkasins®, may replace sensory deficits related to gait and balance dysfunction experienced by patients with PN. Further research is needed to determine if other patients will have a similar response and what the necessary threshold of sensory function is to benefit from use of the Walkasins®.
Collapse
Affiliation(s)
- Diane M. Wrisley
- Department of Physical Therapy, Wingate University, Wingate, NC, United States
- Doctor of Physical Therapy Program, College of St Mary, Omaha, NE, United States
| | - Gillian McLean
- Department of Physical Therapy, Wingate University, Wingate, NC, United States
- Fyzical Therapy and Balance Centers, Las Vegas, NV, United States
| | - Jennifer Baity Hill
- Department of Physical Therapy, Wingate University, Wingate, NC, United States
- OrthoCarolina Outpatient Winston-Salem, Winston-Salem, NC, United States
| | - Lars I. E. Oddsson
- Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, United States
- Recanati School of Community Health, Ben Gurion University of the Negev, Beersheba, Israel
- RxFunction Inc., Eden Prairie, MN, United States
| |
Collapse
|
25
|
Richmond SB, Fling BW, Lee H, Peterson DS. The assessment of center of mass and center of pressure during quiet stance: Current applications and future directions. J Biomech 2021; 123:110485. [PMID: 34004395 DOI: 10.1016/j.jbiomech.2021.110485] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 04/12/2021] [Accepted: 04/19/2021] [Indexed: 11/25/2022]
Abstract
This perspective article provides a brief review of our understanding of how center of pressure (CoP) and center of mass (CoM) are traditionally utilized to measure quiet standing and how technological advancements are allowing for measurements to be derived outside the confines of a laboratory setting. Furthermore, this viewpoint provides descriptions of what CoP and CoM outcomes may reflect, a discussion of recent developments in selected balance outcomes, the importance of measuring instantaneous balance outcomes, and directions for future questions/research. Considering the enormous number and cost of falls annually, conclusions drawn from this perspective underscore the need for more cohesive efforts to advance our understanding of balance performance. As we refine the technology and algorithms used to portably assess postural stability, the question of which measurement (i.e. CoP or CoM) to utilize seems to be highly dependent on the question being asked. Further, the complexity of the question appears to span multiple disciplines and cultivate exploration of the intrinsic mechanisms of stability. Recently developed multi-dimensional methods for assessing balance performance may provide additional insight into balance, improving our ability to predict balance impairments and falls outside the laboratory and in the clinic. However, additional work will be necessary to understand the clinical significance and predictive capacity of these outcomes in various fall-prone populations.
Collapse
Affiliation(s)
- Sutton B Richmond
- College of Health and Human Performance, Department of Applied Physiology and Kinesiology, University of Florida, 1864 Stadium Rd., Gainesville, FL 32608, USA
| | - Brett W Fling
- College of Health and Human Sciences, Department of Health and Exercise Science, Colorado State University, 951 Plum St, Fort Collins, CO 80523, USA; Molecular, Cellular and Integrative Neurosciences Program, Colorado State University, 1675 Campus Delivery, Fort Collins, CO 80523, USA
| | - Hyunglae Lee
- School for Engineering of Matter, Transport and Energy, Arizona State University, 501 E Tyler Mall, Tempe, AZ 85287, USA
| | - Daniel S Peterson
- College of Health Solutions, Arizona State University, 425 N 5(th) Street, Phoenix, AZ, USA; Phoenix VA Health Care System, 650 Indian School Rd. Phoenix, AZ, USA.
| |
Collapse
|
26
|
An Intelligent In-Shoe System for Gait Monitoring and Analysis with Optimized Sampling and Real-Time Visualization Capabilities. SENSORS 2021; 21:s21082869. [PMID: 33921846 PMCID: PMC8074136 DOI: 10.3390/s21082869] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 04/11/2021] [Accepted: 04/15/2021] [Indexed: 12/26/2022]
Abstract
The deterioration of gait can be used as a biomarker for ageing and neurological diseases. Continuous gait monitoring and analysis are essential for early deficit detection and personalized rehabilitation. The use of mobile and wearable inertial sensor systems for gait monitoring and analysis have been well explored with promising results in the literature. However, most of these studies focus on technologies for the assessment of gait characteristics, few of them have considered the data acquisition bandwidth of the sensing system. Inadequate sampling frequency will sacrifice signal fidelity, thus leading to an inaccurate estimation especially for spatial gait parameters. In this work, we developed an inertial sensor based in-shoe gait analysis system for real-time gait monitoring and investigated the optimal sampling frequency to capture all the information on walking patterns. An exploratory validation study was performed using an optical motion capture system on four healthy adult subjects, where each person underwent five walking sessions, giving a total of 20 sessions. Percentage mean absolute errors (MAE%) obtained in stride time, stride length, stride velocity, and cadence while walking were 1.19%, 1.68%, 2.08%, and 1.23%, respectively. In addition, an eigenanalysis based graphical descriptor from raw gait cycle signals was proposed as a new gait metric that can be quantified by principal component analysis to differentiate gait patterns, which has great potential to be used as a powerful analytical tool for gait disorder diagnostics.
Collapse
|
27
|
Allum JHJ, Rust HM, Lutz N, Schouenborg C, Fischer-Barnicol B, Haller V, Derfuss T, Kuhle J, Yaldizli Ö. Characteristics of improvements in balance control using vibro-tactile biofeedback of trunk sway for multiple sclerosis patients. J Neurol Sci 2021; 425:117432. [PMID: 33839367 DOI: 10.1016/j.jns.2021.117432] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 03/27/2021] [Accepted: 03/29/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND AIMS Previously, we determined that training with vibrotactile feedback (VTfb) of trunk sway improves MS patients' balance impairment. Here, we posed 5 questions: 1) How many weeks of VTfb training are required to obtain the best short-term carry over effect (CoE) with VTfb? 2) How long does the CoE last once VTfb training terminates? 3) Is the benefit similar for stance and gait? 4) Is position or velocity based VTfb more effective in reducing trunk sway? 5) Do patients' subjective assessments of balance control improve? METHODS Balance control of 16 MS patients was measured with gyroscopes at the lower trunk. The gyroscopes drove directionally active VTfb in a head-band. Patients trained twice per week with VTfb for 4 weeks to determine when balance control with and without VTfb stopped improving. Thereafter, weekly assessments without VTfb over 4 weeks and at 6 months determined when CoEs ended. RESULTS A 20% improvement in balance to normal levels occurred with VTfb. Short term CoEs improved from 15 to 20% (p ≤ 0.001). Medium term (1-4 weeks) CoEs were constant at 19% (p ≤ 0.001). At 6 months improvement was not significant, 9%. Most improvement was for lateral sway. Equal improvement occurred when angle position or velocity drove VTfb. Subjectively, balance improvements peaked after 3 weeks of training (32%, p ≤ 0.05). CONCLUSIONS 3-4 weeks VTfb training yields clinically relevant sway reductions and subjective improvements for MS patients during stance and gait. The CoEs lasted at least 1 month. Velocity-based VTfb was equally effective as position-based VTfb.
Collapse
Affiliation(s)
- J H J Allum
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland; Dept of ORL, University of Basel Hospital, Basel, Switzerland.
| | - H M Rust
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland; Dept of ORL, University of Basel Hospital, Basel, Switzerland
| | - N Lutz
- Bern University of Applied Sciences, Department of Health Professions, Switzerland
| | - C Schouenborg
- Bern University of Applied Sciences, Department of Health Professions, Switzerland
| | | | - V Haller
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland
| | - T Derfuss
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland
| | - J Kuhle
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland
| | - Ö Yaldizli
- Dept of Neurology, University of Basel Hospital, Basel, Switzerland
| |
Collapse
|
28
|
De la Torre J, Marin J, Polo M, Gómez-Trullén EM, Marin JJ. MCQ-Balance: a method to monitor patients with balance disorders and improve clinical interpretation of posturography. PeerJ 2021; 9:e10916. [PMID: 33665033 PMCID: PMC7908886 DOI: 10.7717/peerj.10916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 01/18/2021] [Indexed: 11/20/2022] Open
Abstract
Background An estimated 20% to 30% of the global population has suffered a vertiginous episode. Among them, 20% do not receive a clear diagnosis. Improved methods, indicators and metrics are necessary to assess the sensory systems related to balance, especially when patients are undergoing treatment for vertiginous episodes. Patients with balance disorders should be monitored for changes at the individual level to gather objective information. In this study, we evaluate the use of the MCQ-Balance (Measure, Classify and Qualify) assessment for examining a patient’s balance progression using tests to measure static balance control and dynamic postural balance with a stabilometric platform. Materials and Methods The MCQ-Balance assessment comprises three stages: (i) measuring the progression of each variable between two separate and consecutive days (called sessions) using the Magnitude-Based Decision analysis; (ii) classifying the progression of the patient’s balance with a score; and (iii) qualifying the progression of the patient’s balance from the resulting scores using a set of rules. This method was applied to 42 patients with balance disorders of peripheral or central origin characterised by vertigo as the cardinal symptom. Balance progression was measured using the MCQ-Balance assessment over the course of three months, and these results were compared with the assessment of a clinical expert. Results The MCQ-Balance assessment showed an accuracy of 83.4% and a Cohen’s Kappa coefficient of 0.752 compared to the assessment of a clinical expert. Conclusion The MCQ-Balance assessment facilitates the monitoring of patient balance and provides objective information that has the potential to improve medical decision making and the adjustment of individual treatment.
Collapse
Affiliation(s)
- Juan De la Torre
- IDERGO (Research and Development in Ergonomics) Research Group, I3A (Aragon Institute of Engineering Research), Zaragoza, Spain.,Department of Biomedical Engineering, Universidad de Zaragoza, Zaragoza, Spain
| | - Javier Marin
- IDERGO (Research and Development in Ergonomics) Research Group, I3A (Aragon Institute of Engineering Research), Zaragoza, Spain.,Department of Design and Manufacturing Engineering, Universidad de Zaragoza, Zaragoza, Spain
| | - Marco Polo
- MD Physical Medicine and Rehabilitation, Hospital of Alcañiz, Teruel, Spain
| | - Eva M Gómez-Trullén
- IDERGO (Research and Development in Ergonomics) Research Group, I3A (Aragon Institute of Engineering Research), Zaragoza, Spain.,Department of Physical Medicine and Rehabilitation and Nursing, Health Sciences Faculty, Universidad de Zaragoza, Zaragoza, Spain
| | - Jose J Marin
- IDERGO (Research and Development in Ergonomics) Research Group, I3A (Aragon Institute of Engineering Research), Zaragoza, Spain.,Department of Design and Manufacturing Engineering, Universidad de Zaragoza, Zaragoza, Spain
| |
Collapse
|
29
|
Dünnwald T, Kienast R, Niederseer D, Burtscher M. The Use of Pulse Oximetry in the Assessment of Acclimatization to High Altitude. SENSORS 2021; 21:s21041263. [PMID: 33578839 PMCID: PMC7916608 DOI: 10.3390/s21041263] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/22/2021] [Accepted: 02/03/2021] [Indexed: 02/07/2023]
Abstract
Background: Finger pulse oximeters are widely used to monitor physiological responses to high-altitude exposure, the progress of acclimatization, and/or the potential development of high-altitude related diseases. Although there is increasing evidence for its invaluable support at high altitude, some controversy remains, largely due to differences in individual preconditions, evaluation purposes, measurement methods, the use of different devices, and the lacking ability to interpret data correctly. Therefore, this review is aimed at providing information on the functioning of pulse oximeters, appropriate measurement methods and published time courses of pulse oximetry data (peripheral oxygen saturation, (SpO2) and heart rate (HR), recorded at rest and submaximal exercise during exposure to various altitudes. Results: The presented findings from the literature review confirm rather large variations of pulse oximetry measures (SpO2 and HR) during acute exposure and acclimatization to high altitude, related to the varying conditions between studies mentioned above. It turned out that particularly SpO2 levels decrease with acute altitude/hypoxia exposure and partly recover during acclimatization, with an opposite trend of HR. Moreover, the development of acute mountain sickness (AMS) was consistently associated with lower SpO2 values compared to individuals free from AMS. Conclusions: The use of finger pulse oximetry at high altitude is considered as a valuable tool in the evaluation of individual acclimatization to high altitude but also to monitor AMS progression and treatment efficacy.
Collapse
Affiliation(s)
- Tobias Dünnwald
- Institute for Sports Medicine, Alpine Medicine and Health Tourism (ISAG), UMIT—Private University for Health Sciences, Medical Informatics and Technology, 6060 Hall in Tirol, Austria;
| | - Roland Kienast
- Department of Biomedical and Health Technology, Federal Higher Technical Institute for Education and Experimentation—HTL Anichstraße, 6020 Innsbruck, Austria;
| | - David Niederseer
- Department of Cardiology, University Hospital Zurich, University Heart Center Zurich, University of Zurich, 8091 Zurich, Switzerland;
| | - Martin Burtscher
- Department of Sport Science, University of Innsbruck, 6020 Innsbruck, Austria
- Correspondence:
| |
Collapse
|
30
|
Gawronska A, Pajor A, Zamyslowska-Szmytke E, Rosiak O, Jozefowicz-Korczynska M. Usefulness of Mobile Devices in the Diagnosis and Rehabilitation of Patients with Dizziness and Balance Disorders: A State of the Art Review. Clin Interv Aging 2020; 15:2397-2406. [PMID: 33376315 PMCID: PMC7764625 DOI: 10.2147/cia.s289861] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 12/09/2020] [Indexed: 11/23/2022] Open
Abstract
Objective The gold standard for objective body posture examination is posturography. Body movements are detected through the use of force platforms that assess static and dynamic balance (conventional posturography). In recent years, new technologies like wearable sensors (mobile posturography) have been applied during complex dynamic activities to diagnose and rehabilitate balance disorders. They are used in healthy people, especially in the aging population, for detecting falls in the older adults, in the rehabilitation of different neurological, osteoarticular, and muscular system diseases, and in vestibular disorders. Mobile devices are portable, lightweight, and less expensive than conventional posturography. The vibrotactile system can consist of an accelerometer (linear acceleration measurement), gyroscopes (angular acceleration measurement), and magnetometers (heading measurement, relative to the Earth’s magnetic field). The sensors may be mounted to the trunk (most often in the lumbar region of the spine, and the pelvis), wrists, arms, sternum, feet, or shins. Some static and dynamic clinical tests have been performed with the use of wearable sensors. Smartphones are widely used as a mobile computing platform and to evaluate the results or monitor the patient during the movement and rehabilitation. There are various mobile applications for smartphone-based balance systems. Future research should focus on validating the sensitivity and reliability of mobile device measurements compared to conventional posturography. Conclusion Smartphone based mobile devices are limited to one sensor lumbar level posturography and offer basic clinical evaluation. Single or multi sensor mobile posturography is available from different manufacturers and offers single to multi-level measurements, providing more data and in some instances even performing sophisticated clinical balance tests.
Collapse
Affiliation(s)
- Anna Gawronska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Anna Pajor
- Department of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Ewa Zamyslowska-Szmytke
- Balance Disorders Unit, Department of Audiology and Phoniatrics, Nofer Institute of Occupational Medicine, Lodz, Poland
| | - Oskar Rosiak
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Magdalena Jozefowicz-Korczynska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| |
Collapse
|
31
|
Zhang G, Wong IKK, Chen TLW, Hong TTH, Wong DWC, Peng Y, Yan F, Wang Y, Tan Q, Zhang M. Identifying Fatigue Indicators Using Gait Variability Measures: A Longitudinal Study on Elderly Brisk Walking. SENSORS 2020; 20:s20236983. [PMID: 33297364 PMCID: PMC7730469 DOI: 10.3390/s20236983] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 12/01/2020] [Accepted: 12/04/2020] [Indexed: 12/23/2022]
Abstract
Real-time detection of fatigue in the elderly during physical exercises can help identify the stability and thus falling risks which are commonly achieved by the investigation of kinematic parameters. In this study, we aimed to identify the change in gait variability parameters from inertial measurement units (IMU) during a course of 60 min brisk walking which could lay the foundation for the development of fatigue-detecting wearable sensors. Eighteen elderly people were invited to participate in the brisk walking trials for 60 min with a single IMU attached to the posterior heel region of the dominant side. Nine sets of signals, including the accelerations, angular velocities, and rotation angles of the heel in three anatomical axes, were measured and extracted at the three walking times (baseline, 30th min, and 60th min) of the trial for analysis. Sixteen of eighteen participants reported fatigue after walking, and there were significant differences in the median acceleration (p = 0.001), variability of angular velocity (p = 0.025), and range of angle rotation (p = 0.0011), in the medial–lateral direction. In addition, there were also significant differences in the heel pronation angle (p = 0.005) and variability and energy consumption of the angles in the anterior–posterior axis (p = 0.028, p = 0.028), medial–lateral axis (p = 0.014, p = 0.014), and vertical axis (p = 0.002, p < 0.001). Our study demonstrated that a single IMU on the posterior heel of the dominant side can address the variability of kinematics parameters for elderly performing prolonged brisk walking and could serve as an indicator for walking instability, and thus fatigue.
Collapse
Affiliation(s)
- Guoxin Zhang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Ivy Kwan-Kei Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Tony Lin-Wei Chen
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Tommy Tung-Ho Hong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
- Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen 518057, China
| | - Yinghu Peng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Fei Yan
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Yan Wang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
- Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen 518057, China
| | - Qitao Tan
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
| | - Ming Zhang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China; (G.Z.); (I.K.-K.W.); (T.L.-W.C.); (T.T.-H.H.); (D.W.-C.W.); (Y.P.); (F.Y.); (Y.W.); (Q.T.)
- Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen 518057, China
- Correspondence: ; Tel.: +852-2766-4939
| |
Collapse
|
32
|
Ma CZH, Lam WK, Chang BC, Lee WCC. Can Insoles Be Used to Improve Static and Dynamic Balance of Community-Dwelling Older Adults? A Systematic Review on Recent Advances and Future Perspectives. J Aging Phys Act 2020; 28:971-986. [PMID: 32498037 DOI: 10.1123/japa.2019-0293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 03/21/2020] [Accepted: 03/22/2020] [Indexed: 11/18/2022]
Abstract
This systematic review investigated the effects of orthopedic, vibrating, and textured insoles on the postural balance of community-dwelling older adults. Articles published in English from 1999 to 2019 investigating the effects of (a) orthopedic, (b) vibrating, and (c) textured insoles on static and dynamic balance in community-dwelling older adults were considered. Twenty-four trials with a total of 634 older adults were identified. The information gathered generally supported the balance-improving effects of orthopedic, vibrating, and textured insoles in both static and dynamic conditions among community-dwelling older adults. Further examination found that rigidity, texture patterns, vibration thresholds, and components like arch supports and heel cups are important factors in determining whether insoles can improve balance. This review highlights the potential of insoles for improving the static and dynamic balance of community-dwelling older adults. Good knowledge in insole designs and an understanding of medical conditions of older adults are required when attempts are made to improve postural balance using insoles.
Collapse
|
33
|
Lind CM, Yang L, Abtahi F, Hanson L, Lindecrantz K, Lu K, Forsman M, Eklund J. Reducing postural load in order picking through a smart workwear system using real-time vibrotactile feedback. APPLIED ERGONOMICS 2020; 89:103188. [PMID: 32854822 DOI: 10.1016/j.apergo.2020.103188] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 04/08/2020] [Accepted: 06/07/2020] [Indexed: 06/11/2023]
Abstract
Vibrotactile feedback training may be one possible method for interventions that target at learning better work techniques and improving postures in manual handling. This study aimed to evaluate the short term effect of real-time vibrotactile feedback on postural exposure using a smart workwear system for work postures intervention in simulated industrial order picking. Fifteen workers at an industrial manufacturing plant performed order-picking tasks, in which the vibrotactile feedback was used for postural training at work. The system recorded the trunk and upper arm postures. Questionnaires and semi-structured interviews were conducted about the users' experience of the system. The results showed reduced time in trunk inclination ≥20°, ≥30° and ≥45° and dominant upper arm elevation ≥30° and ≥45° when the workers received feedback, and for trunk inclination ≥20°, ≥30° and ≥45° and dominant upper arm elevation ≥30°, after feedback withdrawal. The workers perceived the system as useable, comfortable, and supportive for learning. The system has the potential of contributing to improved postures in order picking through an automated short-term training program.
Collapse
Affiliation(s)
- Carl Mikael Lind
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden.
| | - Liyun Yang
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden
| | - Farhad Abtahi
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden
| | - Lars Hanson
- The Virtual Systems Research Centre, School of Engineering Science, University of Skövde, Skövde, Sweden; User Centred Product Design, Global Industrial Development, Scania CV, Södertälje, Sweden
| | - Kaj Lindecrantz
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden; Faculty of Textiles, University of Borås, SE-501 90, Borås, Sweden
| | - Ke Lu
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden
| | - Mikael Forsman
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden
| | - Jörgen Eklund
- Unit of Occupational Medicine, Karolinska Institutet, Solnavägen 4, SE-113 65, Stockholm, Sweden; Division of Ergonomics, KTH Royal Institute of Technology, Hälsovägen 11C, SE-141 57, Huddinge, Sweden
| |
Collapse
|
34
|
Applying the Minimal Detectable Change of a Static and Dynamic Balance Test Using a Portable Stabilometric Platform to Individually Assess Patients with Balance Disorders. Healthcare (Basel) 2020; 8:healthcare8040402. [PMID: 33066627 PMCID: PMC7712175 DOI: 10.3390/healthcare8040402] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 09/09/2020] [Accepted: 10/12/2020] [Indexed: 12/29/2022] Open
Abstract
Balance disorders have a high prevalence among elderly people in developed countries, and falls resulting from balance disorders involve high healthcare costs. Therefore, tools and indicators are necessary to assess the response to treatments. Therefore, the aim of this study is to detect relevant changes through minimal detectable change (MDC) values in patients with balance disorders, specifically with vertigo. A test-retest of a static and dynamic balance test was conducted on 34 healthy young volunteer subjects using a portable stabilometric platform. Afterwards, in order to show the MDC applicability, eight patients diagnosed with balance disorders characterized by vertigo of vestibular origin performed the balance test before and after a treatment, contrasting the results with the assessment by a specialist physician. The balance test consisted of four tasks from the Romberg test for static balance control, assessing dynamic postural balance through the limits of stability (LOS). The results obtained in the test-retest show the reproducibility of the system as being similar to or better than those found in the literature. Regarding the static balance variables with the lowest MDC value, we highlight the average velocity of the center of pressure (COP) in all tasks and the root mean square (RMS), the area, and the mediolateral displacement in soft surface, with eyes closed. In LOS, all COP limits and the average speed of the COP and RMS were highlighted. Of the eight patients assessed, an agreement between the specialist physician and the balance test results exists in six of them, and for two of the patients, the specialist physician reported no progression, whereas the balance test showed worsening. Patients showed changes that exceeded the MDC values, and these changes were correlated with the results reported by the specialist physician. We conclude that (at least for these eight patients) certain variables were sufficiently sensitive to detect changes linked to balance progression. This is intended to improve decision making and individualized patient monitoring.
Collapse
|
35
|
Eguchi R, Michael B, Howard M, Takahashi M. Shift-Adaptive Estimation of Joint Angle Using Instrumented Brace With Two Stretch Sensors Based on Gaussian Mixture Models. IEEE Robot Autom Lett 2020. [DOI: 10.1109/lra.2020.3010486] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
36
|
An J, Kim J, Lai EC, Lee BC. Effects of a Smartphone-Based Wearable Telerehabilitation System for In-Home Dynamic Weight-Shifting Balance Exercises by Individuals with Parkinson's Disease. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:5678-5681. [PMID: 33019265 DOI: 10.1109/embc44109.2020.9175967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This paper describes the effects of a smartphone-based wearable telerehabilitation system (called Smarter Balance System, SBS) intended for in-home dynamic weight-shifting balance exercises (WSBEs) by individuals with Parkinson's disease (PD). Two individuals with idiopathic PD performed in-home dynamic WSBEs in anterior-posterior (A/P) and medial-lateral (M/L) directions, using the SBS 3 days per week for 6 weeks. Exercise performance was quantified by cross-correlation (XCORR) and position error (PE) analyses. Balance and gait performance and level of fear of falling were assessed by limit of stability (LOS), Sensory Organization Test (SOT), Falls Efficacy Scale (FES), Activities-specific Balance Confidence (ABC), and Dynamic Gait Index (DGI) at the pre-(beginning of week 1), post-(end of week 6), and retention-(1 month after week 6) assessments. Regression analyses found that exponential trends of the XCORR and PE described exercise performance more effectively than linear trends. Range of LOS in both A/P and M/L directions improved at the post-assessment compared to the pre-assessment, and was retained at the retention assessment. The preliminary findings emphasize the advantages of wearable balance telerehabilitation technologies when performing in-home balance rehabilitation exercises.
Collapse
|
37
|
Fifteen Years of Wireless Sensors for Balance Assessment in Neurological Disorders. SENSORS 2020; 20:s20113247. [PMID: 32517315 PMCID: PMC7308812 DOI: 10.3390/s20113247] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 05/25/2020] [Accepted: 06/03/2020] [Indexed: 12/12/2022]
Abstract
Balance impairment is a major mechanism behind falling along with environmental hazards. Under physiological conditions, ageing leads to a progressive decline in balance control per se. Moreover, various neurological disorders further increase the risk of falls by deteriorating specific nervous system functions contributing to balance. Over the last 15 years, significant advancements in technology have provided wearable solutions for balance evaluation and the management of postural instability in patients with neurological disorders. This narrative review aims to address the topic of balance and wireless sensors in several neurological disorders, including Alzheimer’s disease, Parkinson’s disease, multiple sclerosis, stroke, and other neurodegenerative and acute clinical syndromes. The review discusses the physiological and pathophysiological bases of balance in neurological disorders as well as the traditional and innovative instruments currently available for balance assessment. The technical and clinical perspectives of wearable technologies, as well as current challenges in the field of teleneurology, are also examined.
Collapse
|
38
|
Chander H, Burch RF, Talegaonkar P, Saucier D, Luczak T, Ball JE, Turner A, Kodithuwakku Arachchige SNK, Carroll W, Smith BK, Knight A, Prabhu RK. Wearable Stretch Sensors for Human Movement Monitoring and Fall Detection in Ergonomics. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17103554. [PMID: 32438649 PMCID: PMC7277680 DOI: 10.3390/ijerph17103554] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 05/15/2020] [Accepted: 05/16/2020] [Indexed: 11/16/2022]
Abstract
Wearable sensors are beneficial for continuous health monitoring, movement analysis, rehabilitation, evaluation of human performance, and for fall detection. Wearable stretch sensors are increasingly being used for human movement monitoring. Additionally, falls are one of the leading causes of both fatal and nonfatal injuries in the workplace. The use of wearable technology in the workplace could be a successful solution for human movement monitoring and fall detection, especially for high fall-risk occupations. This paper provides an in-depth review of different wearable stretch sensors and summarizes the need for wearable technology in the field of ergonomics and the current wearable devices used for fall detection. Additionally, the paper proposes the use of soft-robotic-stretch (SRS) sensors for human movement monitoring and fall detection. This paper also recapitulates the findings of a series of five published manuscripts from ongoing research that are published as Parts I to V of “Closing the Wearable Gap” journal articles that discuss the design and development of a foot and ankle wearable device using SRS sensors that can be used for fall detection. The use of SRS sensors in fall detection, its current limitations, and challenges for adoption in human factors and ergonomics are also discussed.
Collapse
Affiliation(s)
- Harish Chander
- Neuromechanics Laboratory, Department of Kinesiology, Mississippi State University, Mississippi State, MS 39762, USA; (A.T.); (S.N.K.K.A.); (A.K.)
- Correspondence:
| | - Reuben F. Burch
- Department of Human Factors & Athlete Engineering, Center for Advanced Vehicular Systems (CAVS), Mississippi State University, Mississippi State, MS 39762, USA;
| | - Purva Talegaonkar
- Department of Industrial & Systems Engineering, Mississippi State University, Mississippi State, MS 39762, USA; (P.T.); (B.K.S.)
| | - David Saucier
- Department of Electrical & Computer Engineering, Mississippi State University, Mississippi State, MS 39762, USA; (D.S.); (J.E.B.); (W.C.)
| | - Tony Luczak
- National Strategic Planning and Analysis Research Center (NSPARC), Mississippi State University, Mississippi State, MS 39762, USA;
| | - John E. Ball
- Department of Electrical & Computer Engineering, Mississippi State University, Mississippi State, MS 39762, USA; (D.S.); (J.E.B.); (W.C.)
| | - Alana Turner
- Neuromechanics Laboratory, Department of Kinesiology, Mississippi State University, Mississippi State, MS 39762, USA; (A.T.); (S.N.K.K.A.); (A.K.)
| | | | - Will Carroll
- Department of Electrical & Computer Engineering, Mississippi State University, Mississippi State, MS 39762, USA; (D.S.); (J.E.B.); (W.C.)
| | - Brian K. Smith
- Department of Industrial & Systems Engineering, Mississippi State University, Mississippi State, MS 39762, USA; (P.T.); (B.K.S.)
| | - Adam Knight
- Neuromechanics Laboratory, Department of Kinesiology, Mississippi State University, Mississippi State, MS 39762, USA; (A.T.); (S.N.K.K.A.); (A.K.)
| | - Raj K. Prabhu
- Department of Agricultural and Biomedical Engineering, Mississippi State University, Mississippi State, MS 39762, USA;
| |
Collapse
|
39
|
Cruz-Montecinos C, Cuesta-Vargas A, Muñoz C, Flores D, Ellsworth J, De la Fuente C, Calatayud J, Rivera-Lillo G, Soto-Arellano V, Tapia C, García-Massó X. Impact of Visual Biofeedback of Trunk Sway Smoothness on Motor Learning during Unipedal Stance. SENSORS 2020; 20:s20092585. [PMID: 32370050 PMCID: PMC7248825 DOI: 10.3390/s20092585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 04/24/2020] [Accepted: 04/27/2020] [Indexed: 12/16/2022]
Abstract
The assessment of trunk sway smoothness using an accelerometer sensor embedded in a smartphone could be a biomarker for tracking motor learning. This study aimed to determine the reliability of trunk sway smoothness and the effect of visual biofeedback of sway smoothness on motor learning in healthy people during unipedal stance training using an iPhone 5 measurement system. In the first experiment, trunk sway smoothness in the reliability group (n = 11) was assessed on two days, separated by one week. In the second, the biofeedback group (n = 12) and no-biofeedback group (n = 12) were compared during 7 days of unipedal stance test training and one more day of retention (without biofeedback). The intraclass correlation coefficient score 0.98 (0.93–0.99) showed that this method has excellent test–retest reliability. Based on the power law of practice, the biofeedback group showed greater improvement during training days (p = 0.003). Two-way mixed analysis of variance indicates a significant difference between groups (p < 0.001) and between days (p < 0.001), as well as significant interaction (p < 0.001). Post hoc analysis shows better performance in the biofeedback group from training days 2 and 7, as well as on the retention day (p < 0.001). Motor learning objectification through visual biofeedback of trunk sway smoothness enhances postural control learning and is useful and reliable for assessing motor learning.
Collapse
Affiliation(s)
- Carlos Cruz-Montecinos
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
- Biomechanics and Kinesiology Laboratory, Hospital San José, 8380419 Santiago, Chile
| | - Antonio Cuesta-Vargas
- Department of Physiotherapy, Faculty of Heath Sciences, University of Malaga, 29071 Málaga, Spain;
- Institute of Biomedical Research in Malaga (IBIMA), 29010 Málaga, Spain
- School of Clinical Science, Faculty of Health Science, Queensland University Technology, Brisbane, QLD 4000, Australia
| | - Cristian Muñoz
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
| | - Dante Flores
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
| | - Joseph Ellsworth
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
| | - Carlos De la Fuente
- Carrera de Kinesiología, Departamento de Cs. de la Salud, Facultad de Medicina, Pontificia Universidad Católica, 7820436 Santiago, Chile;
- Laboratorio LIBFE, Escuela de Kinesiología, Universidad de los Andes, 7620086 Santiago, Chile
- Centro de Salud Deportiva, Clínica Santa María, 7520378 Santiago, Chile
| | - Joaquín Calatayud
- Exercise Intervention for Health Research Group (EXINH-RG), Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain;
| | - Gonzalo Rivera-Lillo
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
- Neuroscience Department, University of Chile, 8380453 Santiago, Chile
- Research and Development Unit, Clínica Los Coihues, 9190025 Santiago, Chile
| | | | - Claudio Tapia
- Clinical Biomechanics Laboratory, Department of Physical Therapy, University of Chile, 8380453 Santiago, Chile; (C.C.-M.); (C.M.); (D.F.); (J.E.); (G.R.-L.)
- Universidad Tecnológica de Chile INACAP, Escuela Salud, 8340536 Santiago, Chile
- Correspondence:
| | - Xavier García-Massó
- Human Movement Analysis Group (HuMAG), University of Valencia, 46022 Valencia, Spain;
| |
Collapse
|
40
|
Escamilla-Nunez R, Michelini A, Andrysek J. Biofeedback Systems for Gait Rehabilitation of Individuals with Lower-Limb Amputation: A Systematic Review. SENSORS 2020; 20:s20061628. [PMID: 32183338 PMCID: PMC7146745 DOI: 10.3390/s20061628] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 03/11/2020] [Accepted: 03/12/2020] [Indexed: 12/17/2022]
Abstract
Individuals with lower-limb amputation often have gait deficits and diminished mobility function. Biofeedback systems have the potential to improve gait rehabilitation outcomes. Research on biofeedback has steadily increased in recent decades, representing the growing interest toward this topic. This systematic review highlights the methodological designs, main technical and clinical challenges, and evidence relating to the effectiveness of biofeedback systems for gait rehabilitation. This review provides insights for developing an effective, robust, and user-friendly wearable biofeedback system. The literature search was conducted on six databases and 31 full-text articles were included in this review. Most studies found biofeedback to be effective in improving gait. Biofeedback was most commonly concurrently provided and related to limb loading and symmetry ratios for stance or step time. Visual feedback was the most used modality, followed by auditory and haptic. Biofeedback must not be obtrusive and ideally provide a level of enjoyment to the user. Biofeedback appears to be most effective during the early stages of rehabilitation but presents some usability challenges when applied to the elderly. More research is needed on younger populations and higher amputation levels, understanding retention as well as the relationship between training intensity and performance.
Collapse
Affiliation(s)
- Rafael Escamilla-Nunez
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M4Y 1R5, Canada; (R.E.-N.); (A.M.)
- Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada
| | - Alexandria Michelini
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M4Y 1R5, Canada; (R.E.-N.); (A.M.)
- Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada
| | - Jan Andrysek
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M4Y 1R5, Canada; (R.E.-N.); (A.M.)
- Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada
- Correspondence:
| |
Collapse
|
41
|
Brennan L, Dorronzoro Zubiete E, Caulfield B. Feedback Design in Targeted Exercise Digital Biofeedback Systems for Home Rehabilitation: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2019; 20:E181. [PMID: 31905653 PMCID: PMC6982782 DOI: 10.3390/s20010181] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 12/18/2019] [Accepted: 12/23/2019] [Indexed: 01/23/2023]
Abstract
Digital biofeedback systems (DBSs) are used in physical rehabilitation to improve outcomes by engaging and educating patients and have the potential to support patients while doing targeted exercises during home rehabilitation. The components of feedback (mode, content, frequency and timing) can influence motor learning and engagement in various ways. The feedback design used in DBSs for targeted exercise home rehabilitation, as well as the evidence underpinning the feedback and how it is evaluated, is not clearly known. To explore these concepts, we conducted a scoping review where an electronic search of PUBMED, PEDro and ACM digital libraries was conducted from January 2000 to July 2019. The main inclusion criteria included DBSs for targeted exercises, in a home rehabilitation setting, which have been tested on a clinical population. Nineteen papers were reviewed, detailing thirteen different DBSs. Feedback was mainly visual, concurrent and descriptive, frequently providing knowledge of results. Three systems provided clear rationale for the use of feedback. Four studies conducted specific evaluations of the feedback, and seven studies evaluated feedback in a less detailed or indirect manner. Future studies should describe in detail the feedback design in DBSs and consider a robust evaluation of the feedback element of the intervention to determine its efficacy.
Collapse
Affiliation(s)
- Louise Brennan
- Physiotherapy department, Beacon Hospital, Bracken Road, Sandyford Industrial Estate, Dublin 18, Ireland
- Insight Centre for Data Analytics, O’Brien Science Centre, University College Dublin, Dublin 4, Ireland;
- School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin 4, Ireland
| | | | - Brian Caulfield
- Insight Centre for Data Analytics, O’Brien Science Centre, University College Dublin, Dublin 4, Ireland;
- School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin 4, Ireland
| |
Collapse
|
42
|
Use of Wearable Sensor Technology in Gait, Balance, and Range of Motion Analysis. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app10010234] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
More than 8.6 million people suffer from neurological disorders that affect their gait and balance. Physical therapists provide interventions to improve patient’s functional outcomes, yet balance and gait are often evaluated in a subjective and observational manner. The use of quantitative methods allows for assessment and tracking of patient progress during and after rehabilitation or for early diagnosis of movement disorders. This paper surveys the state-of-the-art in wearable sensor technology in gait, balance, and range of motion research. It serves as a point of reference for future research, describing current solutions and challenges in the field. A two-level taxonomy of rehabilitation assessment is introduced with evaluation metrics and common algorithms utilized in wearable sensor systems.
Collapse
|
43
|
Closing the Wearable Gap—Part III: Use of Stretch Sensors in Detecting Ankle Joint Kinematics During Unexpected and Expected Slip and Trip Perturbations. ELECTRONICS 2019. [DOI: 10.3390/electronics8101083] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Background: An induced loss of balance resulting from a postural perturbation has been reported as the primary source for postural instability leading to falls. Hence; early detection of postural instability with novel wearable sensor-based measures may aid in reducing falls and fall-related injuries. The purpose of the study was to validate the use of a stretchable soft robotic sensor (SRS) to detect ankle joint kinematics during both unexpected and expected slip and trip perturbations. Methods: Ten participants (age: 23.7 ± 3.13 years; height: 170.47 ± 8.21 cm; mass: 82.86 ± 23.4 kg) experienced a counterbalanced exposure of an unexpected slip, an unexpected trip, an expected slip, and an expected trip using treadmill perturbations. Ankle joint kinematics for dorsiflexion and plantarflexion were quantified using three-dimensional (3D) motion capture through changes in ankle joint range of motion and using the SRS through changes in capacitance when stretched due to ankle movements during the perturbations. Results: A greater R-squared and lower root mean square error in the linear regression model was observed in comparing ankle joint kinematics data from motion capture with stretch sensors. Conclusions: Results from the study demonstrated that 71.25% of the trials exhibited a minimal error of less than 4.0 degrees difference from the motion capture system and a greater than 0.60 R-squared value in the linear model; suggesting a moderate to high accuracy and minimal errors in comparing SRS to a motion capture system. Findings indicate that the stretch sensors could be a feasible option in detecting ankle joint kinematics during slips and trips.
Collapse
|
44
|
Ghislieri M, Gastaldi L, Pastorelli S, Tadano S, Agostini V. Wearable Inertial Sensors to Assess Standing Balance: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4075. [PMID: 31547181 PMCID: PMC6806601 DOI: 10.3390/s19194075] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 09/12/2019] [Accepted: 09/17/2019] [Indexed: 02/06/2023]
Abstract
Wearable sensors are de facto revolutionizing the assessment of standing balance. The aim of this work is to review the state-of-the-art literature that adopts this new posturographic paradigm, i.e., to analyse human postural sway through inertial sensors directly worn on the subject body. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 73 full-text articles, selecting 47 high-quality contributions. A good inter-rater reliability was obtained (Cohen's kappa = 0.79). This selection of papers was used to summarize the available knowledge on the types of sensors used and their positioning, the data acquisition protocols and the main applications in this field (e.g., "active aging", biofeedback-based rehabilitation for fall prevention, and the management of Parkinson's disease and other balance-related pathologies), as well as the most adopted outcome measures. A critical discussion on the validation of wearable systems against gold standards is also presented.
Collapse
Affiliation(s)
- Marco Ghislieri
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy.
| | - Laura Gastaldi
- Department of Mathematical Sciences, Politecnico di Torino, 10129 Torino, Italy.
| | - Stefano Pastorelli
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Torino, Italy.
| | - Shigeru Tadano
- National Institute of Technology, Hakodate College, Hakodatate 042-8501, Japan.
- Division of Human Mechanical Systems and Design, Faculty of Engineering, Hokkaido University, Sapporo 060-0808, Japan.
| | - Valentina Agostini
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy.
| |
Collapse
|
45
|
Systematic Analysis of a Military Wearable Device Based on a Multi-Level Fusion Framework: Research Directions. SENSORS 2019; 19:s19122651. [PMID: 31212742 PMCID: PMC6631929 DOI: 10.3390/s19122651] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 05/28/2019] [Accepted: 06/10/2019] [Indexed: 02/04/2023]
Abstract
With the development of the Internet of Battlefield Things (IoBT), soldiers have become key nodes of information collection and resource control on the battlefield. It has become a trend to develop wearable devices with diverse functions for the military. However, although densely deployed wearable sensors provide a platform for comprehensively monitoring the status of soldiers, wearable technology based on multi-source fusion lacks a generalized research system to highlight the advantages of heterogeneous sensor networks and information fusion. Therefore, this paper proposes a multi-level fusion framework (MLFF) based on Body Sensor Networks (BSNs) of soldiers, and describes a model of the deployment of heterogeneous sensor networks. The proposed framework covers multiple types of information at a single node, including behaviors, physiology, emotions, fatigue, environments, and locations, so as to enable Soldier-BSNs to obtain sufficient evidence, decision-making ability, and information resilience under resource constraints. In addition, we systematically discuss the problems and solutions of each unit according to the frame structure to identify research directions for the development of wearable devices for the military.
Collapse
|
46
|
Koehler-McNicholas SR, Danzl L, Cataldo AY, Oddsson LIE. Neuromodulation to improve gait and balance function using a sensory neuroprosthesis in people who report insensate feet - A randomized control cross-over study. PLoS One 2019; 14:e0216212. [PMID: 31039180 PMCID: PMC6490932 DOI: 10.1371/journal.pone.0216212] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 04/13/2019] [Indexed: 12/16/2022] Open
Abstract
Peripheral neuropathy may cause loss of sensory information from plantar cutaneous mechanoreceptors that is important for balance control and falls management. The current study investigated short-term effects of using Walkasins, an external lower-limb sensory neuroprosthesis, on clinical outcomes of balance and gait in persons who reported peripheral neuropathy and balance problems. The device replaces lost plantar sensation with tactile balance information that modulates cutaneous mechanoreceptors above the ankle where sensation is intact. Thirty-one male community-dwelling Veterans, 56–84 years old with insensate feet and balance problems participated. Initial Functional Gait Assessment, gait speed, and 4-Stage Balance Test outcomes were assessed. After initial assessment, subjects were randomly assigned to either wearing Walkasins turned ON, or OFF, and outcomes were re-assessed following a set of standardized balance exercises. Following a one-hour rest and washout period, treatments were crossed-over between groups and a third outcomes assessment was performed. Before cross-over, 10 of 15 subjects in the ON-then-OFF group improved their Functional Gait Assessment score by at least four points, the Minimal Clinically Important Difference, compared to 5 of 16 in the OFF-then-ON group. After cross-over, 7 of 16 subjects in the OFF-then-ON group improved by at least four points versus 2 of 15 in the ON-then-OFF group. ON treatment was associated with a Functional Gait Assessment improvement of 4.4 ± 3.7 points versus 1.5 ± 1.2 for the OFF treatment (p<0.01). Overall, Functional Gait Assessment scores changed from 15.2 ± 4.8 at initial assessment to 21.1 ± 5.2 after final assessment (p<0.001). At the end of the two treatment sessions, 16 of the 31 individuals had improved their Functional Gait Assessment score beyond 23, indicating normal fall-risk status. Future studies should investigate long-term benefits of the device to reduce fall risk and actual falls in patients with peripheral neuropathy and balance problems.
Collapse
Affiliation(s)
- Sara R. Koehler-McNicholas
- Minneapolis Department of Veterans Affairs Health Care System, Minneapolis, MN, United States of America
- * E-mail:
| | - Lori Danzl
- Minneapolis Department of Veterans Affairs Health Care System, Minneapolis, MN, United States of America
| | - Alana Y. Cataldo
- Minneapolis Department of Veterans Affairs Health Care System, Minneapolis, MN, United States of America
| | - Lars I. E. Oddsson
- Division of Rehabilitation Science, Department of Rehabilitation Medicine, Medical School, University of Minnesota, Minneapolis, MN, United States of America
- Recanati School of Community Health, Ben Gurion University of the Negev, Be’er Sheva, Israel
- RxFunction Inc., Eden Prairie, MN, United States of America
| |
Collapse
|
47
|
Fleszar Z, Mellone S, Giese M, Tacconi C, Becker C, Schöls L, Synofzik M, Ilg W. Real-time use of audio-biofeedback can improve postural sway in patients with degenerative ataxia. Ann Clin Transl Neurol 2019; 6:285-294. [PMID: 30847361 PMCID: PMC6389757 DOI: 10.1002/acn3.699] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 09/16/2018] [Accepted: 10/26/2018] [Indexed: 11/08/2022] Open
Abstract
Objective Cerebellar ataxia essentially includes deficient postural control. It remains unclear whether augmented sensory information might help cerebellar patients, as the cerebellum underlies processing of various sensory modalities for postural control. Here, we hypothesized that patients with cerebellar degeneration can still exploit audio-biofeedback (ABF) of trunk acceleration as a real-time assistive signal to compensate for deficient postural control. Methods Effects on postural sway during stance were assessed in an ABF intervention group versus a no-ABF disease control group (23 vs. 17 cerebellar patients) in a clinico-experimental study. A single-session ABF paradigm of standing plus short exergaming under ABF was applied. Postural sway with eyes open and eyes closed was quantified prior to ABF, under ABF, and post ABF. Results Postural sway in the eyes closed condition was significantly reduced under ABF. Both benefit of ABF and benefit of vision correlated with the extent of postural sway at baseline, and both types of sensory benefits correlated with each other. Patients with strongest postural sway exhibited reduced postural sway also with eyes open, thus benefitting from both vision and ABF. No changes were observed in the no-ABF control group. Interpretation Our findings provide proof-of-principle evidence that subjects with cerebellar degeneration are still able to integrate additional sensory modalities to compensate for deficient postural control: They can use auditory cues functionally similar to vision in the absence of vision, and additive to vision in the presence of vision (in case of pronounced postural sway). These findings might inform future assistive strategies for cerebellar ataxia.
Collapse
Affiliation(s)
- Zofia Fleszar
- Department of Cognitive Neurology Hertie Institute for Clinical Brain Research Tübingen Germany.,Centre for Integrative Neuroscience (CIN) Tübingen Germany.,Department of Neurodegeneration Hertie Institute for Clinical Brain Research and Centre of Neurology Tübingen Germany
| | - Sabato Mellone
- Personal Health Systems Lab Department of Electrical Electronic and Information Engineering «Guglielmo Marconi» University of Bologna Bologna Italy
| | - Martin Giese
- Department of Cognitive Neurology Hertie Institute for Clinical Brain Research Tübingen Germany.,Centre for Integrative Neuroscience (CIN) Tübingen Germany
| | - Carlo Tacconi
- Health Sciences and Technologies - Interdepartmental Center for Industrial Research University of Bologna Bologna Italy
| | - Clemens Becker
- Department of Clinical Gerontology Robert-Bosch-Hospital Stuttgart Germany
| | - Ludger Schöls
- Department of Neurodegeneration Hertie Institute for Clinical Brain Research and Centre of Neurology Tübingen Germany.,German Research Center for Neurodegenerative Diseases (DZNE) Tübingen Germany
| | - Matthis Synofzik
- Department of Neurodegeneration Hertie Institute for Clinical Brain Research and Centre of Neurology Tübingen Germany.,German Research Center for Neurodegenerative Diseases (DZNE) Tübingen Germany
| | - Winfried Ilg
- Department of Cognitive Neurology Hertie Institute for Clinical Brain Research Tübingen Germany.,Centre for Integrative Neuroscience (CIN) Tübingen Germany
| |
Collapse
|
48
|
Verification of a Portable Motion Tracking System for Remote Management of Physical Rehabilitation of the Knee. SENSORS 2019; 19:s19051021. [PMID: 30823373 PMCID: PMC6427361 DOI: 10.3390/s19051021] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/05/2019] [Accepted: 02/21/2019] [Indexed: 01/06/2023]
Abstract
Rehabilitation following knee injury or surgery is critical for recovery of function and independence. However, patient non-adherence remains a significant barrier to success. Remote rehabilitation using mobile health (mHealth) technologies have potential for improving adherence to and execution of home exercise. We developed a remote rehabilitation management system combining two wireless inertial measurement units (IMUs) with an interactive mobile application and a web-based clinician portal (interACTION). However, in order to translate interACTION into the clinical setting, it was first necessary to verify the efficacy of measuring knee motion during rehabilitation exercises for physical therapy and determine if visual feedback significantly improves the participant’s ability to perform the exercises correctly. Therefore, the aim of this study was to verify the accuracy of the IMU-based knee angle measurement system during three common physical therapy exercises, quantify the effect of visual feedback on exercise performance, and understand the qualitative experience of the user interface through survey data. A convenience sample of ten healthy control participants were recruited for an IRB-approved protocol. Using the interACTION application in a controlled laboratory environment, participants performed ten repetitions of three knee rehabilitation exercises: heel slides, short arc quadriceps contractions, and sit-to-stand. The heel slide exercise was completed without feedback from the mobile application, then all exercises were performed with visual feedback. Exercises were recorded simultaneously by the IMU motion tracking sensors and a video-based motion tracking system. Validation showed moderate to good agreement between the two systems for all exercises and accuracy was within three degrees. Based on custom usability survey results, interACTION was well received. Overall, this study demonstrated the potential of interACTION to measure range of motion during rehabilitation exercises for physical therapy and visual feedback significantly improved the participant’s ability to perform the exercises correctly.
Collapse
|
49
|
Morone G, Spitoni GF, De Bartolo D, Ghanbari Ghooshchy S, Di Iulio F, Paolucci S, Zoccolotti P, Iosa M. Rehabilitative devices for a top-down approach. Expert Rev Med Devices 2019; 16:187-195. [PMID: 30677307 DOI: 10.1080/17434440.2019.1574567] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
INTRODUCTION In recent years, neurorehabilitation has moved from a 'bottom-up' to a 'top down' approach. This change has also involved the technological devices developed for motor and cognitive rehabilitation. It implies that during a task or during therapeutic exercises, new 'top-down' approaches are being used to stimulate the brain in a more direct way to elicit plasticity-mediated motor re-learning. This is opposed to 'Bottom up' approaches, which act at the physical level and attempt to bring about changes at the level of the central neural system. AREAS COVERED In the present unsystematic review, we present the most promising innovative technological devices that can effectively support rehabilitation based on a top-down approach, according to the most recent neuroscientific and neurocognitive findings. In particular, we explore if and how the use of new technological devices comprising serious exergames, virtual reality, robots, brain computer interfaces, rhythmic music and biofeedback devices might provide a top-down based approach. EXPERT COMMENTARY Motor and cognitive systems are strongly harnessed in humans and thus cannot be separated in neurorehabilitation. Recently developed technologies in motor-cognitive rehabilitation might have a greater positive effect than conventional therapies.
Collapse
Affiliation(s)
- Giovanni Morone
- a Private Inpatient Unit , Santa Lucia foundation IRCCS , Rome , Italy.,b Clinical Laboratory of Experimental Neurorehabilitation , Santa Lucia Foundation IRCCS , Rome , Italy
| | - Grazia Fernanda Spitoni
- c Department of Psychology , Sapienza University of Rome , Rome , Italy.,d Laboratory of Neuropsychology , IRCCS Santa Lucia Foundation , Rome , Italy
| | - Daniela De Bartolo
- b Clinical Laboratory of Experimental Neurorehabilitation , Santa Lucia Foundation IRCCS , Rome , Italy.,c Department of Psychology , Sapienza University of Rome , Rome , Italy
| | - Sheida Ghanbari Ghooshchy
- b Clinical Laboratory of Experimental Neurorehabilitation , Santa Lucia Foundation IRCCS , Rome , Italy.,c Department of Psychology , Sapienza University of Rome , Rome , Italy
| | - Fulvia Di Iulio
- e UOC 3 Neurorihabilitation Santa Lucia Foundation IRCCS , Rome , Italy
| | - Stefano Paolucci
- a Private Inpatient Unit , Santa Lucia foundation IRCCS , Rome , Italy.,b Clinical Laboratory of Experimental Neurorehabilitation , Santa Lucia Foundation IRCCS , Rome , Italy
| | | | - Marco Iosa
- b Clinical Laboratory of Experimental Neurorehabilitation , Santa Lucia Foundation IRCCS , Rome , Italy
| |
Collapse
|
50
|
Ma CZH, Ling YT, Shea QTK, Wang LK, Wang XY, Zheng YP. Towards Wearable Comprehensive Capture and Analysis of Skeletal Muscle Activity during Human Locomotion. SENSORS 2019; 19:s19010195. [PMID: 30621103 PMCID: PMC6339139 DOI: 10.3390/s19010195] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 12/22/2018] [Accepted: 01/04/2019] [Indexed: 11/21/2022]
Abstract
Background: Motion capture and analyzing systems are essential for understanding locomotion. However, the existing devices are too cumbersome and can be used indoors only. A newly-developed wearable motion capture and measurement system with multiple sensors and ultrasound imaging was introduced in this study. Methods: In ten healthy participants, the changes in muscle area and activity of gastrocnemius, plantarflexion and dorsiflexion of right leg during walking were evaluated by the developed system and the Vicon system. The existence of significant changes in a gait cycle, comparison of the ankle kinetic data captured by the developed system and the Vicon system, and test-retest reliability (evaluated by the intraclass correlation coefficient, ICC) in each channel’s data captured by the developed system were examined. Results: Moderate to good test-retest reliability of various channels of the developed system (0.512 ≤ ICC ≤ 0.988, p < 0.05), significantly high correlation between the developed system and Vicon system in ankle joint angles (0.638R ≤ 0.707, p < 0.05), and significant changes in muscle activity of gastrocnemius during a gait cycle (p < 0.05) were found. Conclusion: A newly developed wearable motion capture and measurement system with ultrasound imaging that can accurately capture the motion of one leg was evaluated in this study, which paves the way towards real-time comprehensive evaluation of muscles and joint motions during different activities in both indoor and outdoor environments.
Collapse
Affiliation(s)
- Christina Zong-Hao Ma
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
- Department of Rehabilitation, Jönköping University, 551 11 Jönköping, Sweden.
| | - Yan To Ling
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Queenie Tsung Kwan Shea
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Li-Ke Wang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Xiao-Yun Wang
- Guangdong Work Injury Rehabilitation Center, Guangzhou 510440, China.
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
| |
Collapse
|