1
|
Ghasem N. Modeling and Simulation of a Multizone Circulating Reactor for Polyethylene Production with Internal Cooling. Polymers (Basel) 2023; 15:3741. [PMID: 37765595 PMCID: PMC10535281 DOI: 10.3390/polym15183741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/05/2023] [Accepted: 09/09/2023] [Indexed: 09/29/2023] Open
Abstract
Polyolefins play a role in industries and are typically manufactured using two types of reactors: high-pressure tubular reactors and fluidized bed reactors. An innovative technology called the Multizone Circulating reactor (MZCR) has emerged, which introduces an innovative approach with interconnected polymerization zones creating a continuous loop of polymer flow. This study focuses on modeling and simulating ethylene gas phase polymerization within the MZCR in the presence of internal cooling to gain insights into its behavior. To achieve this, a comprehensive computational fluid dynamics (CFD) simulation was developed. It considered momentum, material, and energy balance aspects. The model equations were solved using the finite difference method in COMSOL Multiphysics version 6.1. The investigation primarily focused on studying the impact of incorporating a cooler into the riser section on the temperature profile within the reactor and ethylene conversion. The presence of this cooler resulted in a reduction in temperature change along the riser from approximately 8.0 °C to 4.0 °C. Moreover, it led to an increase of 7%, in ethylene single-pass conversion.
Collapse
Affiliation(s)
- Nayef Ghasem
- Department of Chemical and Petroleum Engineering, United Arab Emirates University, Al-Ain P.O. Box 15551, United Arab Emirates
| |
Collapse
|
2
|
Evaluation of a real-time mobile PCR device (PCR 1100) for the detection of the rabies gene in field samples. Trop Med Health 2023; 51:17. [PMID: 36932428 PMCID: PMC10020757 DOI: 10.1186/s41182-023-00501-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Accepted: 01/23/2023] [Indexed: 03/19/2023] Open
Abstract
BACKGROUND The Philippines is ranked among the top countries with 200-300 annual deaths due to rabies. Most human rabies cases have been reported in remote areas, where dog surveillance is inadequate. Therefore, a strategy to effectively improve surveillance in remote areas will increase the number of detections. Detecting pathogens using portable real-time reverse transcription-polymerase chain reaction (RT-PCR) has the potential to be accepted in these areas. Thus, we aimed to develop an assay to detect the rabies virus (RABV) genome by combining the robust primer system LN34 with the PicoGene PCR1100 portable rapid instrument targeting RABV RNA (PCR1100 assay). METHODS Procedures were optimised using an LN34 primer/probe set, KAPA3G Plant PCR Kit (KAPA Biosystems), FastGene Scriptase II (NIPPON Genetics), and an artificial positive control RNA. RESULTS Positive control RNA showed an analytical limit of detection of 10 copies/µL without false positivity, generating results in approximately 32 min. Compared to dFAT or RT-qPCR using field samples, the sensitivity and specificity of the PCR1100 assay were 100%, and even lower copy numbers (approximately 10 copies/µL) were detected. CONCLUSIONS This study demonstrated that the developed assay can detect rabies RNA in field samples. Because dog-mediated rabies is endemic in remote areas, the rapidity, mobility, and practicality of the PCR1100 assay as well as the high sensitivity of the LN34 system make it an ideal tool for the confirmation of rabies in these areas.
Collapse
|
3
|
Wang J, Jiang H, Pan L, Gu X, Xiao C, Liu P, Tang Y, Fang J, Li X, Lu C. Rapid on-site nucleic acid testing: On-chip sample preparation, amplification, and detection, and their integration into all-in-one systems. Front Bioeng Biotechnol 2023; 11:1020430. [PMID: 36815884 PMCID: PMC9930993 DOI: 10.3389/fbioe.2023.1020430] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 01/12/2023] [Indexed: 02/04/2023] Open
Abstract
As nucleic acid testing is playing a vital role in increasingly many research fields, the need for rapid on-site testing methods is also increasing. The test procedure often consists of three steps: Sample preparation, amplification, and detection. This review covers recent advances in on-chip methods for each of these three steps and explains the principles underlying related methods. The sample preparation process is further divided into cell lysis and nucleic acid purification, and methods for the integration of these two steps on a single chip are discussed. Under amplification, on-chip studies based on PCR and isothermal amplification are covered. Three isothermal amplification methods reported to have good resistance to PCR inhibitors are selected for discussion due to their potential for use in direct amplification. Chip designs and novel strategies employed to achieve rapid extraction/amplification with satisfactory efficiency are discussed. Four detection methods providing rapid responses (fluorescent, optical, and electrochemical detection methods, plus lateral flow assay) are evaluated for their potential in rapid on-site detection. In the final section, we discuss strategies to improve the speed of the entire procedure and to integrate all three steps onto a single chip; we also comment on recent advances, and on obstacles to reducing the cost of chip manufacture and achieving mass production. We conclude that future trends will focus on effective nucleic acid extraction via combined methods and direct amplification via isothermal methods.
Collapse
Affiliation(s)
- Jingwen Wang
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, China
| | - Han Jiang
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, China
| | - Leiming Pan
- Zhejiang Hongzheng Testing Co., Ltd., Ningbo, China
| | - Xiuying Gu
- Zhejiang Gongzheng Testing Center Co., Ltd., Hangzhou, China
| | - Chaogeng Xiao
- Institute of Food Science, Zhejiang Academy of Agricultural Science, Hangzhou, China
| | - Pengpeng Liu
- Key Laboratory of Biosafety detection for Zhejiang Market Regulation, Zhejiang Fangyuan Testing Group LO.T, Hangzhou, China
| | - Yulong Tang
- Hangzhou Tiannie Technology Co., Ltd., Hangzhou, China
| | - Jiehong Fang
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, China
| | - Xiaoqian Li
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, China
| | - Chenze Lu
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, China
| |
Collapse
|
4
|
Chen WY, Shi XL, Zou J, Chen ZG. Thermoelectric Coolers: Progress, Challenges, and Opportunities. SMALL METHODS 2022; 6:e2101235. [PMID: 34989165 DOI: 10.1002/smtd.202101235] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/27/2021] [Indexed: 06/14/2023]
Abstract
Owing to the free of noise, mechanical component, working fluid, and chemical reaction, thermoelectric cooling is regarded as a suitable solution to address the greenhouse emission for the broad cooling scenarios. Here, the significant progress of state-of-the-art thermoelectric coolers is comprehensively summarized and the related aspects of materials, fundamental design, heat sinks, and structures, are overviewed. Particularly, the usage of thermoelectric coolers in smart city, greenhouse, and personal and chip thermal management is highlighted. In the end, current challenges and future opportunities for further improvement of designs, performance, and applications of thermoelectric coolers are pointed out.
Collapse
Affiliation(s)
- Wen-Yi Chen
- School of Mechanical and Ming Engineering, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Xiao-Lei Shi
- School of Mechanical and Ming Engineering, The University of Queensland, Brisbane, Queensland, 4072, Australia
- Centre for Future Materials, University of Southern Queensland, Springfield Central, Queensland, 4300, Australia
- School of Chemistry and Physics, Queensland University of Technology, Brisbane, Queensland, 4000, Australia
| | - Jin Zou
- School of Mechanical and Ming Engineering, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Zhi-Gang Chen
- School of Mechanical and Ming Engineering, The University of Queensland, Brisbane, Queensland, 4072, Australia
- Centre for Future Materials, University of Southern Queensland, Springfield Central, Queensland, 4300, Australia
- School of Chemistry and Physics, Queensland University of Technology, Brisbane, Queensland, 4000, Australia
| |
Collapse
|
5
|
He L, Sang B, Wu W. Battery-Powered Portable Rotary Real-Time Fluorescent qPCR with Low Energy Consumption, Low Cost, and High Throughput. BIOSENSORS-BASEL 2020; 10:bios10050049. [PMID: 32397069 PMCID: PMC7277348 DOI: 10.3390/bios10050049] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 04/28/2020] [Accepted: 05/03/2020] [Indexed: 12/19/2022]
Abstract
The traditional qPCR instrument is bulky, expensive, and inconvenient to carry, so we report a portable rotary real-time fluorescent PCR (polymerase chain reaction) that completes the PCR amplification of DNA in the field, and the reaction can be observed in real-time. Through the analysis of a target gene, namely pGEM-3Zf (+), the gradient amplification and melting curves are compared to commercial devices. The results confirm the stability of our device. This is the first use of a mechanical rotary structure to achieve gradient amplification curves and melting curves comparable to commercial instruments. The average power consumption of our system is about 7.6 W, which is the lowest energy consumption for real-time fluorescence quantification in shunting PCR and enables the use of our device in the field thanks to its self-contained power supply based on a lithium battery. In addition, all of the equipment costs only about 710 dollars, which is far lower than the cost of a commercial PCR instrument because the control system through mechanical displacement replaces the traditional TEC (thermoelectric cooler) temperature control. Moreover, the equipment has a low technical barrier, which can suit the needs of non-professional settings, with strong repeatability.
Collapse
Affiliation(s)
- Limin He
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (L.H.); (B.S.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Benliang Sang
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (L.H.); (B.S.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Wenming Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China; (L.H.); (B.S.)
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
- Correspondence:
| |
Collapse
|
6
|
A New Self-Activated Micropumping Mechanism Capable of Continuous-Flow and Real-Time PCR Amplification Inside 3D Spiral Microreactor. MICROMACHINES 2019; 10:mi10100685. [PMID: 31614591 PMCID: PMC6843785 DOI: 10.3390/mi10100685] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 09/29/2019] [Accepted: 10/07/2019] [Indexed: 11/29/2022]
Abstract
A self-activated micropump which is capable of stable velocity transport for a liquid to flow a given distance inside a 3D microchannel has been a dream of microfluidic scientists for a long time. A new self-activated pumping mechanism has been proposed in this paper. It is different from the authors’ previous research which relied on the fluid resistance of a quartz capillary tube or end-blocked gas-permeable silicone or a polydimethylsiloxane (PDMS) wall to automate the flow. In this research, an end-open stretched Teflon tube was utilized for passive transport for the first time. A new fluid transmission mode was adopted with the assistance of a cheaper easily accessible oil mixture to achieve stable continuous flow. Finally, this novel micropump has been applied to real-time continuous-flow polymerase chain reactions (PCRs), with an amplification efficiency similar to that of a commercial PCR cycler instrument.
Collapse
|