1
|
Wang M, Huang X, Huang Q. Investigating the Mass Sensitivity of Quartz Crystal Microbalances with Circularly Symmetric Electrodes in the Third Overtone Mode. Anal Chem 2024; 96:20552-20558. [PMID: 39663767 DOI: 10.1021/acs.analchem.4c04966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2024]
Abstract
This study investigates the mass sensitivity of a quartz crystal microbalance (QCM) with a circular symmetric electrode (M-M type) operating in the third overtone mode and finds that its central mass sensitivity is nearly five times greater than that of the fundamental mode, as determined through a deposition experiment, rather than the three times greater central mass sensitivity predicted by classical theory. The reasons for this phenomenon were determined through a combination of theoretical calculation and finite element simulation. The results revealed that (1) compared with the fundamental mode, the third overtone mode exhibits a more pronounced energy trapping effect, leading to a sharper mass sensitivity distribution and a more concentrated sensitivity in the central region and (2) the third overtone resonance frequency is slightly higher than three times the fundamental resonance frequency. This study indicates that operating the QCM in the third overtone mode significantly enhances its mass sensitivity, making it particularly suitable for applications requiring precise detection.
Collapse
Affiliation(s)
- Minghao Wang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Xianhe Huang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Qirui Huang
- Experimental primary school affiliated to University of Electronic Science and Technology of China, Chengdu 610057, China
| |
Collapse
|
2
|
Yang G, Huang X, Tan K, Chen Q, Pan W. Study of Force-Frequency Characteristics in AT-Cut Strip Quartz Crystal Resonators with Different Rotation Angles. SENSORS (BASEL, SWITZERLAND) 2023; 23:2996. [PMID: 36991707 PMCID: PMC10058224 DOI: 10.3390/s23062996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/07/2023] [Accepted: 03/08/2023] [Indexed: 06/19/2023]
Abstract
This paper investigated the force-frequency characteristics of AT-cut strip quartz crystal resonator (QCR) employing finite element analysis methods and experiments. We used the finite element analysis software COMSOL Multiphysics to calculate the stress distribution and particle displacement of the QCR. Moreover, we analyzed the impact of these opposing forces on the frequency shift and strains of the QCR. Meanwhile, the resonant frequency shifts, conductance, and quality factor (Q value) of three AT-cut strip QCRs with rotation angles of 30°, 40°, and 50° under different force-applying positions were tested experimentally. The results showed that the frequency shifts of the QCRs were proportional to the magnitude of the force. The highest force sensitivity was QCR with a rotation angle of 30°, followed by 40°, and 50° was the lowest. And the distance of the force-applying position from the X-axis also affected the frequency shift, conductance, and Q value of the QCR. The results of this paper are instructive for understanding the force-frequency characteristics of strip QCRs with different rotation angles.
Collapse
|
3
|
Enhanced corrosion resistance of epoxy-films on ultra-thin SiOx PECVD film coated laser surface melted Al-alloys. SN APPLIED SCIENCES 2023. [DOI: 10.1007/s42452-022-05244-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
AbstractThe influence of ultra-thin SiOx plasma deposited films on the corrosion resistance of adhesive films on a laser surface melted 7075 aluminium alloy was investigated by means of complementary techniques in comparison to the just laser surface melted state. Laser surface melting (LSM) was performed using a continuous wave mode at a wavelength of 1064 nm. Ultra-thin plasma polymer films were deposited from a mixture of hexamethyldisilane (HMDSO), oxygen, and argon by means of an audio-frequency glow discharge. The surface morphology and surface chemistry compositions were investigated by employing field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy (EDX), diffuse reflection infrared Fourier transform spectroscopy, and X-ray photoelectron spectroscopy. The corrosion resistance of plasma polymer coated LSM Al-7075 alloy was studied using linear sweep voltammetry and electrochemical impedance spectroscopy in a chloride-containing electrolyte. The electrochemical studies showed an improved corrosion resistance for plasma film-coated alloys compared to the just laser surface melted state. To study the corresponding surface adhesive properties, the samples were coated with an epoxy amine adhesive. 90°-peel test under humid conditions confirmed the improvement of interfacial wet-adhesion corrosion tests showed a strong improvement of the delamination resistance of adhesives caused by the ultra-thin interfacial SiOx-films.
Collapse
|
4
|
Pham TKN, Garcia GA, Brown JJ. Measurement of isosteric heat of gas adsorption and Brunauer-Emmett-Teller (BET) surface area using a quartz crystal microbalance. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:064105. [PMID: 35778017 DOI: 10.1063/5.0073233] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 05/28/2022] [Indexed: 06/15/2023]
Abstract
The study of gas adsorption on a solid surface evaluates the affinity between sorbate gas and sorbent substrate and factors that contribute to this. This paper presents a test platform for adsorption experiments of various gases on various solid surfaces. Controlled environmental conditions enable investigations in materials surface science and increase the consistency among adsorption data. The system utilizes a quartz crystal microbalance to perform gravimetric analysis of deposition and adsorption, enabling investigation of the interaction of gaseous molecules with solid surfaces. In this study, a quartz crystal microbalance as gas adsorption detector was integrated with an environmental chamber to create a versatile tool for gas adsorption experiments on thin films. Experimental operation of this apparatus was demonstrated via acquisition of the adsorption isotherms of cyclohexane vapor on a gold surface at 55 and 70 °C. The result indicated International Union of Pure and Applied Chemistry Type II adsorption. Consequentially, application of the Brunauer-Emmett-Teller model to the isotherm data subject to predefined criteria for linear region selection yielded a surface area of the sorbent of 0.53 cm2 at 55 °C. From the monolayer region of the isotherms, the isosteric heat of adsorption of the cyclohexane vapor on gold was calculated to be 37 kJ mol-1.
Collapse
Affiliation(s)
- Thi Kieu Ngan Pham
- Department of Mechanical Engineering, University of Hawai`i at Mānoa, Honolulu, Hawaii 96822, USA
| | - Geoffrey A Garcia
- Department of Mechanical Engineering, University of Hawai`i at Mānoa, Honolulu, Hawaii 96822, USA
| | - Joseph J Brown
- Department of Mechanical Engineering, University of Hawai`i at Mānoa, Honolulu, Hawaii 96822, USA
| |
Collapse
|
5
|
Chen Q, Huang X, Yao Y, Mao K. Analysis of the Effect of Electrode Materials on the Sensitivity of Quartz Crystal Microbalance. NANOMATERIALS 2022; 12:nano12060975. [PMID: 35335788 PMCID: PMC8954940 DOI: 10.3390/nano12060975] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/09/2022] [Accepted: 03/15/2022] [Indexed: 02/04/2023]
Abstract
This paper investigated the effect of electrode materials on the performance of quartz crystal microbalance (QCM) sensors by means of theoretical calculation, experiment, and finite element analysis methods. First, we calculated the particle displacement amplitude and thus obtained the mass sensitivity function distribution of QCMs with gold, silver and aluminum electrodes, and found that the QCM with the gold electrode has the highest mass sensitivity at the center of the electrode. Then, we tested the humidity-sensing performance of QCMs with gold, silver, and aluminum electrodes using graphene oxide (GO) as the sensitive material, and found that the QCM with the gold electrode has higher humidity sensitivity. Finally, we used the finite element analysis software COMSOL Multiphysics to simulate the specific electrode material parameters that affect the sensitivity of the QCMs. The simulation results show that the density and Young’s modulus of the electrode material parameters mainly affect the sensitivity. The results of this paper are instructive for optimizing QCM sensor performance and improving the capability of QCM quantitative analysis.
Collapse
Affiliation(s)
| | | | - Yao Yao
- Correspondence: (X.H.); (Y.Y.)
| | | |
Collapse
|
6
|
Immunoassay of Glomalin by Quartz Crystal Microbalance Biosensor Containing Iron Oxide Nanoparticles. Int J Anal Chem 2020; 2020:8844151. [PMID: 32952559 PMCID: PMC7481945 DOI: 10.1155/2020/8844151] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/03/2020] [Accepted: 08/19/2020] [Indexed: 01/21/2023] Open
Abstract
Glomalin is a soil protein resembling heat shock protein (HSP) 60 and exerting high affinity to metals, causing retention of water in the environment and improving mechanical stability of soil. Currently, glomalin is determined in the soil or other samples by combination of autoclaving extraction and total protein determination typically by the Bradford method. In this paper, a piezoelectric biosensor was prepared to determine glomalin in a label-free measurement. The biosensor contained antibodies immobilized on quartz crystal microbalance (QCM), and the recognition layer was stabilized by iron oxide nanoparticles. The assay was tested on real soil samples and compared with the standard Bradford assay. Limit of detection of the assay was equal to 2.4 µg/g for a soil extract with a volume of 50 µl. The assay takes approximately half of an hour and was fully correlated to the Bradford assay. The biosensor had significant advantages than the other methods: it worked in a label-free mode and was fully applicable for practical samples.
Collapse
|
7
|
Pan W, Huang X, Chen Q. Uniformization of Mass Sensitivity Distribution of Silver Electrode QCM. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1953-1956. [PMID: 32746208 DOI: 10.1109/tuffc.2020.3008790] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Quartz crystal microbalance (QCM) is a highly sensitive mass sensor and has been widely used in many fields. However, the nonuniform distribution of mass sensitivity will lead to poor reproducibility of QCM, which is not conducive to the application of QCM in some fields. Considering the effect of electrode shape, size, and material on mass sensitivity distribution, we found that for an AT-cut QCM with a fundamental frequency of 10 MHz, when the inner and outer diameters of silver ring electrode and the electrode loading factor are 2 and 5 mm and 0.0033, respectively, an approximately uniform mass sensitivity distribution can be obtained. The plating experiment in which rigid silver films were plated on the surface of electrode verified the uniformity. The uniform mass sensitivity distribution will make the application of QCM more convenient; the reproducibility can also be improved. This design of QCM will enrich QCM products and facilitate the application of QCM in various fields.
Collapse
|
8
|
Chen Q, Feng NB, Huang XH, Yao Y, Jin YR, Pan W, Liu D. Humidity-Sensing Properties of a BiOCl-Coated Quartz Crystal Microbalance. ACS OMEGA 2020; 5:18818-18825. [PMID: 32775883 PMCID: PMC7408249 DOI: 10.1021/acsomega.0c01946] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/08/2020] [Indexed: 05/26/2023]
Abstract
The performance of a bismuth oxychloride (BiOCl)-based quartz crystal microbalance (QCM) humidity sensor was studied using an oscillating circuit method. The BiOCl powder was prepared by a hydrolysis method. Scanning electron microscopy, X-ray diffraction, and Fourier transform infrared spectroscopy were used to characterize the BiOCl sample. Its humidity-sensing property was analyzed by combining it with a QCM at room temperature (25 °C). Experimental results indicated that the BiOCl-based QCM sensor showed good humidity characteristics from 11.3 to 97.3%, such as good logarithmic frequency response to humidity levels (R 2 = 0.994), fast response time (5.2 s)/recovery time (4.5 s), good reversibility, stability, repeatability, and low humidity hysteresis. In addition, the response to human nose breaths showed excellent practicability. Finally, the humidity sensing mechanism of the BiOCl-based QCM humidity sensor was discussed in detail. This work demonstrates that BiOCl is a promising candidate material for humidity detection.
Collapse
Affiliation(s)
- Qiao Chen
- School
of Automation Engineering, University of
Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, Chengdu, Sichuan 611731, China
| | - Ning-bo Feng
- School
of Materials Science and Engineering, Xihua
University, No. 99 Jinzhou Road, Chengdu, Sichuan 610039, China
| | - Xian-he Huang
- School
of Automation Engineering, University of
Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, Chengdu, Sichuan 611731, China
| | - Yao Yao
- School
of Automation Engineering, University of
Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, Chengdu, Sichuan 611731, China
| | - Ying-rong Jin
- School
of Materials Science and Engineering, Xihua
University, No. 99 Jinzhou Road, Chengdu, Sichuan 610039, China
| | - Wei Pan
- School
of Automation Engineering, University of
Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, Chengdu, Sichuan 611731, China
| | - Dong Liu
- School
of Automation Engineering, University of
Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, Chengdu, Sichuan 611731, China
| |
Collapse
|
9
|
Direct detection of small molecules using a nano-molecular imprinted polymer receptor and a quartz crystal resonator driven at a fixed frequency and amplitude. Biosens Bioelectron 2020; 158:112176. [DOI: 10.1016/j.bios.2020.112176] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 03/09/2020] [Accepted: 03/23/2020] [Indexed: 02/06/2023]
|