1
|
Safiabadi Tali SH, Al-Kassawneh M, Mansouri M, Sadiq Z, Jahanshahi-Anbuhi S. All-Inclusive Sensing Tablet with Integrated Passive Mixer for Ultraviscous Solutions. ACS Sens 2025. [PMID: 40327804 DOI: 10.1021/acssensors.4c03726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2025]
Abstract
Developing low-cost and easy-to-use point-of-care devices is necessary for timely disease diagnosis and health monitoring. Here, we introduce all-inclusive, tablet-based chemo/biosensors with rapid automixing features, capable of mixing in highly viscous solutions with viscosities up to 1700 mPa·s. These tablets are created using a simple powder compression method and contain all necessary reagents to perform assays in a "drop-and-detect" manner, without the need for vigorous shaking or vortex mixing. As proof of concept, we demonstrated the applicability of our Speedy tablets for detecting nitrite in human saliva, a challenging medium due to its viscosity. The strong mixing capability of the proposed tablets ensured consistent and reliable results across range of viscosities, from low to high, while delivering an excellent detection range of 0.03-1.50 mg/dL, covering nitrite levels in human saliva. Additionally, we developed a straightforward method to encapsulate enzymes in trehalose, making them bulkier and more stable using only a mist sprayer, nonstick tray, and spatula, eliminating the need for expensive equipment. This approach allowed us to incorporate small amounts of enzymes into tablet formulations and fabricate the first automixing tablet biosensor. These biosensors were used for the bienzymatic detection of glucose in real human urine within the biologically relevant range of 0.3-2.5 mM, indicating the compatibility of automixing tablets with bioreagents. Each tablet costs less than $0.30 to produce and remains stable for at least one month at room temperature. The affordability and convenience of our tablets make them a valuable addition to the array of diagnostic tools.
Collapse
Affiliation(s)
- Seyed Hamid Safiabadi Tali
- Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Muna Al-Kassawneh
- Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Maryam Mansouri
- Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Zubi Sadiq
- Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Sana Jahanshahi-Anbuhi
- Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec H4B 1R6, Canada
| |
Collapse
|
2
|
Kang HJ, Noh JK, Lee MK, Woo SR, Park JM, Lee YC, Ko SG, Eun YG. Changes of Pepsin Concentration in Saliva Sample According to Storage Period. J Voice 2025; 39:855.e7-855.e10. [PMID: 36588013 DOI: 10.1016/j.jvoice.2022.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 12/31/2022]
Abstract
OBJECTIVES To determine whether the concentration of pepsin in the saliva sample changes according to the storage period of the sample. METHODS Forty eight patients with suspected laryngopharyngeal reflux were included in this study. Saliva samples were collected from each patient and each sample divided into six and stored for different period of time. Pepsin concentration was measured using enzyme-linked immunosorbent assay. A comparison was made between the pepsin concentration measured immediately and the concentration measured after storage for 1 week, 2 weeks, 1 month, 3 months, and 6 months. RESULTS No significant difference in pepsin concentrations were detected between the sample analyzed immediately and those analyzed at 1 week, 2 weeks, 1 month, and 3 months after saliva collection. A significant difference in pepsin concentration was observed in the sample analyzed immediately and the sample analyzed 6 months after saliva collection. CONCLUSIONS Pepsin concentration in saliva samples did not demonstrate a significant difference between the concentration measured immediately and the concentration measured 3 months after saliva collection, although a significant difference was observed in the concentration measured 6 months after collection.
Collapse
Affiliation(s)
- Hee Jin Kang
- Department of Otolaryngology Head & Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Joo Kyung Noh
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul, Republic of Korea
| | - Min Kyeong Lee
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul, Republic of Korea
| | - Seon Rang Woo
- Department of Otolaryngology Head & Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea; Central Laboratory, Medical Science Research Institute, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Jung Min Park
- Department of Otolaryngology Head & Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Young Chan Lee
- Department of Otolaryngology Head & Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea
| | - Seong-Gyu Ko
- Department of Preventive Medicine, College of Korean Medicine, Kyung Hee University, Seoul, Republic of Korea
| | - Young-Gyu Eun
- Department of Otolaryngology Head & Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, Republic of Korea; Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul, Republic of Korea.
| |
Collapse
|
3
|
He Z, Wu J, He Z, Chen J, Fang W, Zhang Y, Shen X, Ren Y, Chen Y, He J, Yan D, Chen P, Zhou M. A Paper-Based Sensor for the Detection of Gastroesophageal Reflux Disease Utilizing a Cleavable Fluorescent Polymer. Adv Healthc Mater 2025; 14:e2402919. [PMID: 39823160 DOI: 10.1002/adhm.202402919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 11/27/2024] [Indexed: 01/19/2025]
Abstract
Nowadays, gastroesophageal reflux disease (GERD) has emerged as one of the major hazards to the health of the upper gastrointestinal tract, and there is an urgent need for a low-cost, user-friendly, and non-invasive detection method. Herein, a paper-based sensor (CP sensor) for the non-invasive screening of GERD is proposed. The sensor is structured as a specially shaped cellulose paper strip embedded with fluorescent colloids, which are self-assembled from a cleavable synthetic fluorescent polymer (P4). Benefiting from the introduction of amide bonds and the unique assembled structure of the nanocolloids, the pepsin in the sample solution will hydrolyze the water-soluble branches in the micellar shell during detection, resulting in a corresponding output of the fluorescent signal. This responsiveness, which can be observed by the naked eye, is so sensitive with a minimum detectable concentration for pepsin as low as 0.3 ng·mL-1. Clinical trials have further demonstrates that the designed paper sensor is capable of providing improved accuracy in the early diagnosis of GERD.
Collapse
Affiliation(s)
- Zejian He
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
- Stoddart Institute of Molecular Science, Department of Chemistry, Zhejiang University, Hangzhou, 310058, P. R. China
- Zhejiang-Israel Joint Laboratory of Self-Assembling Functional Materials, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311215, P. R. China
| | - Jun Wu
- Department of Otolaryngology, The Fourth Affiliated Hospital Zhejiang University School of Medicine, Yiwu, 322000, P. R. China
| | - Zhen He
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| | - Jia Chen
- Otolaryngology Department, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, 310009, P. R. China
| | - Weipin Fang
- Department of Gastroenterology, The First People's Hospital of Jiande, Hangzhou, 311600, P. R. China
| | - Yifan Zhang
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| | - Xinyi Shen
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| | - Yangjing Ren
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| | - Yulong Chen
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| | - Jianguo He
- Otolaryngology Department, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, 310009, P. R. China
| | - Donghai Yan
- Department of Gastroenterology, The First People's Hospital of Jiande, Hangzhou, 311600, P. R. China
| | - Pin Chen
- Department of Clinical Laboratory, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310006, P. R. China
| | - Mi Zhou
- College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, 310014, P. R. China
| |
Collapse
|
4
|
Liu Y, Chen L, Huang J, Zhang J, Chen S, Lin Z, Chen T. A rapid and highly sensitive fluorescence immunochromatographic test strip for pepsin detection in human hypopharyngeal saliva. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2025; 17:1074-1079. [PMID: 39801192 DOI: 10.1039/d4ay01833h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2025]
Abstract
Pepsin serves as a potential biomarker for laryngopharyngeal reflux disease (LPRD). The reported methods for detecting pepsin still have limitations, such as long reaction times and low sensitivity. Therefore, it is crucial to develop a rapid, simple and sensitive detection method. In this study, a fluorescence immunochromatographic test strip was designed for point-of-care diagnostics of LPRD. To obtain optimal fluorescence immunochromatographic conditions, key experimental factors, including microsphere particle size, binding pH, and resuspension dilution ratio, were systematically evaluated. The optimal fluorescent microsphere size was determined to be 300 nm, the most suitable reaction pH was 8.0, and the ideal resuspension solution to storage solution ratio was 1 : 4. Under these optimal conditions, the sensor had a linear range of 2.5-100.0 ng mL-1 and a detection limit of 1.9 ng mL-1. The relative standard deviation was below 15% for both intra- and inter-batch reproducibility. Under accelerated damage conditions at 37 °C, the test value of the test strip could be kept basically unchanged for 14 days. There was no cross-reactivity of the test strip with pepsinogen I, pepsinogen II and other interferents. In the actual sample detection, the recovery rate was between 85% and 115%. Furthermore, the proposed method was demonstrated to be green and to exhibit strong applicability based on the evaluation using the AGREEprep and the BAGI. In addition, the method has the advantages of high sensitivity, accuracy, greenness and applicability, which can meet the needs of rapid quantitative on-site detection.
Collapse
Affiliation(s)
- Yaqi Liu
- Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
| | - Lihong Chen
- Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
| | - Jingtian Huang
- Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
| | - Jialing Zhang
- Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
| | | | - Zhenyu Lin
- MOE Key Laboratory of Analysis and Detection for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, 350108, China.
| | - Ting Chen
- Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
| |
Collapse
|
5
|
Li Y, Ou Y, Fan K, Liu G. Salivary diagnostics: opportunities and challenges. Theranostics 2024; 14:6969-6990. [PMID: 39629130 PMCID: PMC11610148 DOI: 10.7150/thno.100600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Accepted: 09/29/2024] [Indexed: 12/06/2024] Open
Abstract
Saliva contains a diverse array of biomarkers indicative of various diseases. Saliva testing has been a major advancement towards non-invasive point-of-care diagnosis with clinical significance. However, there are challenges associated with salivary diagnosis from sample treatment and standardization. This review highlights the biomarkers in saliva and their role in identifying relevant diseases. It provides an overview and discussion about the current practice of saliva collection and processing, and advancements in saliva detection systems from in vitro methods to wearable oral devices. The review also addresses challenges in saliva diagnostics and proposes solutions, aiming to offer a comprehensive understanding and practical guidance for improving saliva-based detection in clinical diagnosis. Saliva diagnosis provides a rapid, effective, and safe alternative to traditional blood and urine tests for screening large populations and enhancing infectious disease diagnosis and surveillance. It meets the needs of various fields such as disease management, drug screening, and personalized healthcare with advances in saliva detection systems offering high sensitivity, fast response times, portability, and automation. Standardization of saliva collection, treatment, biomarker discovery, and detection between different laboratories needs to be implemented to obtain reliable salivary diagnosis in clinical practice.
Collapse
Affiliation(s)
| | | | | | - Guozhen Liu
- Integrated Devices and Intelligent Diagnosis (ID2) Laboratory, CUHK(SZ)-Boyalife Joint Laboratory for Regenerative Medicine Engineering, Biomedical Engineering Programme, School of Medicine, The Chinese University of Hong Kong, Shenzhen, 518172, China
| |
Collapse
|
6
|
El-Kamel RS, Fekry AM. Enhanced modified poly-tyrosine voltammetric sensor for the quantification detection of salivary pepsin. Int J Biol Macromol 2024; 277:134178. [PMID: 39067726 DOI: 10.1016/j.ijbiomac.2024.134178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 07/30/2024]
Abstract
Pepsin as an aspartic acid protease member and one of the three foremost proteolytic enzymes in the digestive system is essential to be detected. An electrochemically polymerized tyrosine film on carbon paste electrode (pTyr/CPE) has been synthesized by electro-polymerization donating an affordable electrochemical sensor to sense salivary pepsin as a diagnostic technique for gastroesophageal reflux disease (GRD) due to saliva collection is non-invasive and relatively comfortable. The pTyr/CPE was applied for Voltammetric sensing of pepsin and its quantification in phosphate buffer solution of pH 2.0 (PBS). Scanning electron microscopy (SEM) was conducted to learn the surface morphology. Cyclic voltammetry (CV), differential pulse voltammetry (DPVs), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) were developed to realize the electrocatalytic activity of the sensor. The pTyr/CPE proceeded as a sensitive detector to pepsin with two linear ranges from 1 to 20 & 20 to 100 ng/mL donating two limits of detection as 0.5 & 0.09 ng/mL, respectively, and high selectivity toward pepsin, as well as stability and fast response of 1.5 s. Consequently, it is guessed that the pTyr/CPE sensor could be supportive for the initial diagnosis of GRD through the detection of pepsin in saliva. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were agreeable with those from the electrochemical sensor.
Collapse
Affiliation(s)
- Renad S El-Kamel
- Cairo University, Faculty of Science, Department of Chemistry, Giza, Egypt
| | - Amany M Fekry
- Cairo University, Faculty of Science, Department of Chemistry, Giza, Egypt.
| |
Collapse
|
7
|
Meng L, Zhang Q, Meng J, Liu Y, Wang D. Correlation Between Detection Results of Pepsin in Vocal Fold Polyp Tissues and the Postoperative Efficacy. J Voice 2024; 38:1200-1206. [PMID: 35450736 DOI: 10.1016/j.jvoice.2022.02.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 02/23/2022] [Accepted: 02/28/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To explore the correlation between detection results of pepsin in vocal fold polyp tissues and the postoperative efficacy. METHODS The clinical data of 112 patients with vocal fold polyp who received surgical procedures in our hospital from June 2019 to March 2021 were retrospectively analyzed. The vocal fold morphology and vocal acoustic function were assessed at postoperative week 12. Using binary logistic regression, we explored whether the factors, ie, detection result of pepsin in vocal fold polyp tissue, microscopic suturing, the use of CO2 laser, and the history of smoking, affected the postoperative morphological repair of vocal fold polyps. Then, to observe and compare the influence of the detection results of pepsin on the recovery of vocal acoustic function, we divided the enrolled patients into the pepsin group and the pepsin-free group based on the postoperative detection results of pepsin in the polyp tissues by immunohistochemistry, RESULTS: In the 112 patients with vocal fold polyps, positive staining of pepsin in the postoperative samples was found in 76 patients (67.86%) and negative in 36 (32.14%). Totally 80 patients returned to normal in vocal fold morphology, among whom 32 (88.89%) were in pepsin-free group and 48 (63.16%) in pepsin group. Binary logistic regression showed that pepsin was a clinically significant indicator that affected the postoperative morphological recovery of the vocal fold (P = 0.003). Although hoarse voice was improved in all patients at postoperative week 12, the differences were statistically significant in the proportion of patients with grade, roughness, breathiness, asthenia, strain class G, voice handicap index, maximum phonation time, Jitter, Shimmer and noise-to-harmonic ratio between the pepsin group and the pepsin-free group (P < 0.05), with the pepsin-free group being superior to the pepsin group in the improvement of vocal acoustic function. CONCLUSION Pepsin in vocal fold polyps is a clinically significant indicator affecting the postoperative morphological recovery and acoustic efficacy, and patients with negative pepsin are superior to those with positive pepsin in the postoperative recovery of vocal fold morphology and function.
Collapse
Affiliation(s)
- Lingli Meng
- Department of Pathology, Ningbo Diagnostic Pathology Center, Ningbo, China; Department of Histopathology, Ningbo Clinical Pathology Diagnosis Center, Ningbo, China
| | - Qingxiang Zhang
- Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China.
| | - Jie Meng
- Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China
| | - Yaqun Liu
- Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China
| | - Dewang Wang
- Department of Pathology, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China
| |
Collapse
|
8
|
Lee YJ, Noh JK, Woo SR, Kang SW, Eun YG, Lee GJ. Determination of pepsin in human saliva using pepsin-susceptible peptide reporter and colorimetric dipstick assay: a prospective, cross-sectional study. Mikrochim Acta 2024; 191:117. [PMID: 38294558 DOI: 10.1007/s00604-024-06192-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 01/01/2024] [Indexed: 02/01/2024]
Abstract
A simple and effective pepsin detection assay is reported based on a pepsin-susceptible peptide (PSP) reporter degradation strategy. PSP, which can be specifically cleaved by pepsin, was modified with fluorescein isothiocyanate (FITC) and biotin at the N- and C-terminals to be used as a reporter for colorimetric detection of dipsticks. A universal lateral flow dipstick consisting of a streptavidin test line for biotin binding and a sample pad immobilized with a gold-labeled polyclonal (rabbit) anti-FITC antibody was used to verify PSP-based pepsin detection. When the PSP reporter reacts with pepsin in a tube, it cleaves into two fragments, and the cleaved fragments do not display any color on the test line. Therefore, the higher the concentration of pepsin is, the greater is the decrease in test line intensity (IT-line) and the higher is the control line intensity (IC-line). First, the PSP cleavage and dipstick assay conditions for pepsin detection was optimized. The ratio of color intensity (IT-line/IC-line) of PSP-based dipstick assay showed a linear relationship with log concentration of pepsin ranging between 4 and 500 ng/mL (R2 = 0.98, n = 6), with a limit of detection of 1.4 ng/mL. It also exhibited high specificity and good reproducibility. Finally, pepsin levels were quantified in saliva samples from healthy controls (n = 34) and patients with laryngopharyngeal reflux (LPR, n = 61). Salivary pepsin levels were higher in patients with LPR than in healthy controls. The salivary pepsin levels correlated with those measured using a conventional enzyme-linked immunosorbent assay kit. Therefore, this PSP-based dipstick assay is a convenient tool for assessing salivary pepsin levels.
Collapse
Affiliation(s)
- Young Ju Lee
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Republic of Korea
| | - Joo Kyung Noh
- Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul, 02447, Republic of Korea
- Department of Otolaryngology-Head and Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, 02447, Republic of Korea
| | - Seon Rang Woo
- Department of Otolaryngology-Head and Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, 02447, Republic of Korea
| | - Sung-Woong Kang
- Department of Medical Engineering, Kyung Hee University Graduate School, Seoul, 02447, Republic of Korea
| | - Young-Gyu Eun
- Department of Otolaryngology-Head and Neck Surgery, Kyung Hee University School of Medicine, Kyung Hee University Medical Center, Seoul, 02447, Republic of Korea
| | - Gi-Ja Lee
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Republic of Korea.
- Department of Medical Engineering, Kyung Hee University Graduate School, Seoul, 02447, Republic of Korea.
| |
Collapse
|
9
|
Zhou J, Chen X, Wei Y, Lu R, Wei Z, Huang K, Luo H, Zhang J, Zheng C. Portable and Rapid Fluorescence Turn-On Detection of Total Pepsin in Saliva Based on Strong Electrostatic Interactions. Anal Chem 2023; 95:18303-18308. [PMID: 38019658 DOI: 10.1021/acs.analchem.3c04723] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
Salivary pepsin has been proposed as a promising diagnostic marker for gastroesophageal reflux disease (GERD). However, the activity of human pepsin is strongly influenced by pH, and the acidic condition (pH ∼ 2) is optimal, which is a contradiction for the pepsin detection kit based on its catalytic activity. Thus, its accurate quantification in saliva (neutral pH) by readily rapid tools with simplicity and low cost is still challenging. Herein, a convenient fluorescence assay has been developed for the rapid detection of pepsin at neutral pH based on its electrostatic interaction with SYBR Green (SG) rather than the bioactivity. At neutral pH, the positively charged SG fluorophore can be effectively adsorbed by the negatively charged pepsin due to the low isoelectric point (pI) and large molecular size of pepsin. Thus, the molecular rotation of SG is limited, and its fluorescence intensity is significantly increased. The strategy was further confirmed to have the same fluorescence response as that of normally active and inactivated pepsin. Due to the unique pI of pepsin, the fluorescence strategy is highly selective for pepsin compared to other proteins. On the basis of this strategy, a smartphone-based fluorescence capture device integrated with a programmed Python program was fabricated for both color recognition and the accurate detection of pepsin within 3 min. Under the optimal conditions, this turn-on sensor allowed for the on-site analysis of pepsin with a detection limit of 0.2 μg/mL. Moreover, this strategy was successfully used to assess salivary pepsin to aid in the noninvasive diagnosis of GERD.
Collapse
Affiliation(s)
- Jinyan Zhou
- College of Chemistry and Material Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| | - Xueshan Chen
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| | - Yingnan Wei
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| | - Ruixuan Lu
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| | - Zeliang Wei
- Core Facilities of West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Ke Huang
- College of Chemistry and Material Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Hong Luo
- College of Chemistry and Material Science, Sichuan Normal University, Chengdu, Sichuan 610068, China
| | - Jinyi Zhang
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| | - Chengbin Zheng
- Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China
| |
Collapse
|
10
|
Dongiovanni P, Meroni M, Casati S, Goldoni R, Thomaz DV, Kehr NS, Galimberti D, Del Fabbro M, Tartaglia GM. Salivary biomarkers: novel noninvasive tools to diagnose chronic inflammation. Int J Oral Sci 2023; 15:27. [PMID: 37386003 PMCID: PMC10310701 DOI: 10.1038/s41368-023-00231-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 05/23/2023] [Accepted: 06/05/2023] [Indexed: 07/01/2023] Open
Abstract
Several chronic disorders including type 2 diabetes (T2D), obesity, heart disease and cancer are preceded by a state of chronic low-grade inflammation. Biomarkers for the early assessment of chronic disorders encompass acute phase proteins (APP), cytokines and chemokines, pro-inflammatory enzymes, lipids and oxidative stress mediators. These substances enter saliva through the blood flow and, in some cases, there is a close relation between their salivary and serum concentration. Saliva can be easily collected and stored with non-invasive and cost-saving procedures, and it is emerging the concept to use it for the detection of inflammatory biomarkers. To this purpose, the present review aims to discuss the advantages and challenges of using standard and cutting-edge techniques to discover salivary biomarkers which may be used in diagnosis/therapy of several chronic diseases with inflammatory consequences with the pursuit to possibly replace conventional paths with detectable soluble mediators in saliva. Specifically, the review describes the procedures used for saliva collection, the standard approaches for the measurement of salivary biomarkers and the novel methodological strategies such as biosensors to improve the quality of care for chronically affected patients.
Collapse
Affiliation(s)
- Paola Dongiovanni
- Medicine and Metabolic Diseases, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Marica Meroni
- Medicine and Metabolic Diseases, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Sara Casati
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
| | - Riccardo Goldoni
- Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy
- Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni, CNR, Pisa, Italy
| | - Douglas Vieira Thomaz
- Laboratory of Medicinal Pharmaceutical Chemistry, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO, Brazil
| | - Nermin Seda Kehr
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- Department of Chemistry, İzmir Institute of Technology, Gülbahçe Kampüsü, Urla İzmir, Turkey
| | - Daniela Galimberti
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- Neurology-Neurodegenerative Diseases, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- UOC Maxillo-Facial Surgery and Dentistry Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| | - Gianluca M Tartaglia
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- UOC Maxillo-Facial Surgery and Dentistry Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
11
|
Chen H, Feng S, Zhou W, Li Z, Richard-Greenblatt M, Wang P. Pretreatment Methods for Human Nasopharyngeal Swabs to Increase the Signal to Noise Ratio of High Sensitivity Immunoassays. ACS MEASUREMENT SCIENCE AU 2022; 2:414-421. [PMID: 36785662 PMCID: PMC9885992 DOI: 10.1021/acsmeasuresciau.2c00024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Mucous samples collected through nasopharyngeal (NP) swabs are considered gold standard specimens for the detection of respiratory pathogens. Matrices of these highly viscous samples often cause significant background noises in immunoassays, especially immunoassays with high sensitivity. We demonstrated such nonspecific background signals in both a chemiluminescence enzyme-linked immunosorbent assay (ELISA) and a novel highly sensitive immunoassay called Microbubbling SARS-CoV-2 Antigen Assay (MSAA). We developed and demonstrated the effectiveness of two quick sample pretreatment methods, filtration and preadsorption, to decrease nonspecific signals and increase the signal-to-noise ratio (SNR). Using these pretreatment methods, the SNR (at 3.6 × 104 copies/mL of inactivated SARS-CoV-2) was increased by 42.4-fold (95% CI 41.0-43.8) and 67.1-fold (95% CI 57.9-76.3) in the MSAA, and 1.3-fold (95% CI 0.9-1.7) and 1.8-fold (95% CI 1.6-2.0) in the chemiluminescence ELISA assay. Sample pretreatment methods developed in this study are broadly adaptable for the development of immunoassays for highly viscous samples.
Collapse
|
12
|
Zhang J, Wang X, Wang J, Zhao J, Zhang C, Liu Z, Li J. Does hypopharyngeal-esophageal multichannel intraluminal impedance-pH monitoring for the diagnosis of laryngopharyngeal reflux have to be 24 h? Eur Arch Otorhinolaryngol 2022; 279:5323-5329. [PMID: 35864359 DOI: 10.1007/s00405-022-07554-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 07/11/2022] [Indexed: 12/25/2022]
Abstract
PURPOSE To investigate the diagnostic value of combined multi-timepoint salivary pepsin testing (MTPSPT) and hypopharyngeal-esophageal multichannel intraluminal impedance-pH monitoring (HEMII-pH) for laryngopharyngeal reflux (LPR) and whether an appropriate reduction in the duration of HEMII-pH would affect the accuracy of diagnosis of LPR. METHODS Recruited patients were studied with both MTPSPT and HEMII-pH. The diagnosis of LPR was based on the occurrence of > 1 reflux event and/or positive results on any of the MTPSPT. The diagnostic value of combined diagnosis was studied through combining a breakdown of the 24-h HEMII-pH finding and the results of the MTPSPT. The diagnostic value was expressed in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). RESULTS Based on 24-h HEMII-pH and MTPSPT, the positive rate of LPR was 83.33% and 74.69%, respectively. According to the combined diagnosis, the positive rate of LPR was 90.74%. The sensitivity and specificity of the combined diagnosis both were 89.51% and 100%, when the HEMII-pH intervals were 7 a.m.-6 p.m. and 7 a.m.-7 p.m., respectively. However, when the monitoring time was extended to 8 p.m. and bedtime, the sensitivity, specificity, PPV and NPV of the combined diagnosis both were 100%. CONCLUSIONS The combination of MTPSPT and HEMII-pH increased the sensitivity and accuracy of diagnosis of LPR. For patients with positive MTPSPT results, the duration of HEMII-pH can be appropriately shortened to reduce patient sufferings.
Collapse
Affiliation(s)
- Jinhong Zhang
- Department of Otolaryngology, School of Medicine, South China University of Technology, Guangzhou, 510006, China.,Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Xiaoyu Wang
- Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Jiasen Wang
- Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Jing Zhao
- Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Chun Zhang
- Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Zhi Liu
- Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China
| | - Jinrang Li
- Department of Otolaryngology, School of Medicine, South China University of Technology, Guangzhou, 510006, China. .,Department of Otolaryngology, The Sixth Medical Center of PLA General Hospital of Beijing, Beijing, 100048, China.
| |
Collapse
|
13
|
Han SH, Ha YJ, Kang EH, Shin K, Lee YJ, Lee GJ. Electrochemical detection of uric acid in undiluted human saliva using uricase paper integrated electrodes. Sci Rep 2022; 12:12033. [PMID: 35835916 PMCID: PMC9283454 DOI: 10.1038/s41598-022-16176-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 07/06/2022] [Indexed: 11/24/2022] Open
Abstract
In this study, we introduce a uricase-immobilized paper (UOx-paper) integrated electrochemical sensor for detection of uric acid (UA) in saliva. The UOx was immobilized on the detection zone in the wax-patterned paper substrate. This UOx-paper was integrated with a Prussian blue-modified, screen-printed carbon electrode after electropolymerization of o-phenylenediamine to construct an electrochemical cell for small-volume (20 μL) of samples. First, we optimized the fabrication conditions of UOx-paper. Next, the amperometric response of the UOx-paper-based electrochemical UA sensor was analyzed using a known concentration of UA standard solution in artificial saliva at an applied potential of − 0.1 V (versus Ag pseudo-reference electrode). The UOx-paper based electrochemical UA sensor showed a sensitivity of 4.9 μA·mM−1 in a linear range of 50 to 1000 μM (R2 = 0.998), high selectivity and good reproducibility, as well as a limit of detection of 18.7 μM (0.31 mg/dL) UA. Finally, we quantified the UA levels in undiluted saliva samples of healthy controls (n = 20) and gout patients (n = 8). The levels were correlated with those measured with conventional salivary UA enzymatic assays as well as serum UA levels. The UOx-paper-based electrochemical UA sensor is a user-friendly and convenient tool to assess salivary UA levels.
Collapse
Affiliation(s)
- Seong Hyun Han
- Department of Medical Engineering, Kyung Hee University, Graduate School, Seoul, 02447, Republic of Korea
| | - You-Jung Ha
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Eun Ha Kang
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Kichul Shin
- Division of Rheumatology, Seoul Metropolitan Government-Seoul National University Boramae Medical Centre, Seoul, 07061, Republic of Korea
| | - Yun Jong Lee
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea. .,Department of Medical Device Development, Seoul National University Graduate School, Seongnam-si, Gyeonggi-do, 13605, Republic of Korea.
| | - Gi-Ja Lee
- Department of Medical Engineering, Kyung Hee University, Graduate School, Seoul, 02447, Republic of Korea. .,Department of Biomedical Engineering, College of Medicine, Kyung Hee University, #1 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Republic of Korea.
| |
Collapse
|
14
|
Cui Y, Zhang H, Zhu J, Liao Z, Wang S, Liu W. Investigation of Whole and Glandular Saliva as a Biomarker for Alzheimer's Disease Diagnosis. Brain Sci 2022; 12:595. [PMID: 35624982 PMCID: PMC9139762 DOI: 10.3390/brainsci12050595] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 04/26/2022] [Accepted: 04/30/2022] [Indexed: 12/07/2022] Open
Abstract
Salivary Aβ40, Aβ42, t-tau, and p-tau 181 are commonly employed in Alzheimer's disease (AD) investigations. However, the collection method of these biomarkers can affect their levels. To assess the impact of saliva collection methods on biomarkers in this study, 15 healthy people were employed in the morning with six saliva collection methods. The chosen methods were then applied in 30 AD patients and 30 non-AD controls. The levels of salivary biomarkers were calculated by a specific enzyme-linked immunosorbent assay. The receiver operating characteristic was utilized to assess salivary biomarkers in AD patients. The results demonstrated that the highest levels of salivary Aβ40, Aβ42, t-tau, and p-tau were in different saliva collection methods. The correlations between different saliva biomarkers in the same collection method were different. Salivary Aβ40, Aβ42, t-tau, and p-tau had no significant association. Salivary Aβ42 was higher in AD than in non-AD controls. However, p-tau/t-tau and Aβ42/Aβ40 had some relevance. The area under the curve for four biomarkers combined in AD diagnosis was 92.11%. An alternate saliva collection method (e.g., USS in Aβ40, UPS in Aβ42, t-tau, SSS in p-tau 181) was demonstrated in this study. Moreover, combining numerous biomarkers improves AD diagnosis.
Collapse
Affiliation(s)
- Yangyang Cui
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China; (Y.C.); (H.Z.); (J.Z.)
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| | - Hankun Zhang
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China; (Y.C.); (H.Z.); (J.Z.)
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| | - Jia Zhu
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China; (Y.C.); (H.Z.); (J.Z.)
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| | - Zhenhua Liao
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| | - Song Wang
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| | - Weiqiang Liu
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China; (Y.C.); (H.Z.); (J.Z.)
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
- Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057, China;
| |
Collapse
|
15
|
孟 洁, 冯 国, 王 德, 刘 亚, 蔡 明, 孙 川, 张 庆. [The effect of expression of pepsin in vocal polyps on postoperative curative effect]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2022; 36:14-18. [PMID: 34979612 PMCID: PMC10128228 DOI: 10.13201/j.issn.2096-7993.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Indexed: 06/14/2023]
Abstract
Objective:To investigate the effect of tissue pepsin expression of vocal polyps on the postoperative curative effect. Methods:Retrospectively analyze the data of 112 patients diagnosed with vocal cord polyps and undergone surgery from June 2019 to March 2021. The cases were divided into positive group and negative group according to the immunohistochemical pepsin expression. The preoperative reflux symptom index (RSI) and the reflux finding score (RFS) were compared, and the recovery of the voice acoustic function and postoperative vocal cord morphology were analyzed. Results:Among the postoperative specimens of 112 patients,76 cases were positive for pepsin staining, accounting for 67.9%, and 36 cases were negative, accounting for 32.1%. In the pepsin-positive group, 48 cases of vocal cord morphology returned to normal, and 20 cases remained scar or edema in the operation area, 8 cases of polyps relapsed; in the pepsin-negative group, a total of 32 cases of vocal cord morphology returned to normal, 4 cases of remained scar or edema in the operation area, no relapsed cases, the difference in vocal cord morphology recovery was significant (χ²=8.689, P=0.013). The symptoms of hoarseness improved after 12 weeks. The differences between pre and post operative of G grade, VHI, MPT, fundamental frequency perturbation and amplitude perturbation assessed by GRBAS were significant (P<0.05); postoperative G grade, VHI, MPT, fundamental frequency perturbation and amplitude perturbation were compared between the pepsin-positive group and the pepsin-negative group, and the differences were significant (all P<0.05). Conclusion:The expression of pepsin in vocal polyps is a significant clinical indicator that affects the acoustic effect and morphological recovery of vocal cords after surgery. For patients with positive expression, acid suppression treatment should be strengthened after surgery.
Collapse
Affiliation(s)
- 洁 孟
- 东南大学医学院附属南京同仁医院耳鼻咽喉头颈外科 南京同仁耳鼻喉医院(南京,211102)Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, 211102, China
| | - 国建 冯
- 连云港市第二人民医院 连云港市肿瘤医院耳鼻咽喉科Department of Otolaryngology, Second People's Hospital of Lianyungang, Lianyungang Cancer Hospital
| | - 德望 王
- 东南大学医学院附属南京同仁医院病理科Department of Pathology, Nanjing Tongren Hospital, School of Medicine, Southeast University
| | - 亚群 刘
- 东南大学医学院附属南京同仁医院耳鼻咽喉头颈外科 南京同仁耳鼻喉医院(南京,211102)Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, 211102, China
| | - 明静 蔡
- 东南大学医学院附属南京同仁医院耳鼻咽喉头颈外科 南京同仁耳鼻喉医院(南京,211102)Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, 211102, China
| | - 川 孙
- 东南大学医学院附属南京同仁医院耳鼻咽喉头颈外科 南京同仁耳鼻喉医院(南京,211102)Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, 211102, China
| | - 庆翔 张
- 东南大学医学院附属南京同仁医院耳鼻咽喉头颈外科 南京同仁耳鼻喉医院(南京,211102)Department of Otolaryngology Head and Neck Surgery, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, 211102, China
| |
Collapse
|
16
|
Zhang J, Li J, Zhang Y, Nie Q, Zhang R, Wang X, Jiang X, Wu Y, Wu R, Bi X, Cui X, Song H, Ran T, Li L. Multitime point pepsin testing can double the rate of the diagnosis of laryngopharyngeal reflux. Laryngoscope Investig Otolaryngol 2021; 6:1389-1394. [PMID: 34938879 PMCID: PMC8665477 DOI: 10.1002/lio2.700] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/26/2021] [Accepted: 11/10/2021] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVE To study the value of multitime point salivary pepsin testing (MTPSPT) for the diagnosis of laryngopharyngeal reflux (LPR). STUDY DESIGN Prospective noncontrolled. METHODS For patients who met the enrollment criteria, the reflux symptom index (RSI) and reflux finding score (RFS) were calculated and salivary pepsin testing was performed. The pepsin test was performed every hour from 7:00 a.m. to 6:00 p.m. by collecting fresh saliva samples. A single positive test result was needed for the diagnosis of LPR. The consistency in the diagnosis of LPR between the two methods was compared with the weighted Cohen's kappa statistic. RESULTS A total of 204 patients were included. The kappa value between the two methods was 0.566 (p = .00). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MTPSPT were 76.43%, 85.94%, 92.24%, and 62.5%, respectively. We also compared a single pepsin measure at 7 a.m. with the screening results based on the RSI and RFS, and found a much lower kappa agreement value (0.223, p = .00). The sensitivity, specificity, PPV, NPV, and false-negative rate of pepsin testing at 7 a.m. (fasting) were 37.86%, 92.18%, 91.38%, 40.41%, and 58.57%, respectively. CONCLUSION The use of the result of a single salivary pepsin test in the morning yields a relatively higher rate of missed diagnosis of LPR, and multitime point testing through a day increased the accuracy and sensitivity of detection of LPR twofold compared to a single morning fasting sample. LEVEL OF EVIDENCE 3.
Collapse
Affiliation(s)
- Jinhong Zhang
- Department of OtolaryngologySchool of Medicine, South China University of TechnologyGuangzhouChina
- Department of OtolaryngologyThe Sixth Medical Center of PLA General Hospital of BeijingBeijingChina
| | - Jinrang Li
- Department of OtolaryngologySchool of Medicine, South China University of TechnologyGuangzhouChina
- Department of OtolaryngologyThe Sixth Medical Center of PLA General Hospital of BeijingBeijingChina
| | - Yanping Zhang
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Qian Nie
- Department of OtolaryngologyThe Sixth Medical Center of PLA General Hospital of BeijingBeijingChina
| | - Ran Zhang
- Department of OtolaryngologyThe Sixth Medical Center of PLA General Hospital of BeijingBeijingChina
| | - Xiaoyu Wang
- Department of OtolaryngologyThe Sixth Medical Center of PLA General Hospital of BeijingBeijingChina
| | - Xingwang Jiang
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Yingying Wu
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Runze Wu
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Xinxin Bi
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Xiaohuan Cui
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Hui Song
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Taotao Ran
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| | - Lina Li
- Department of OtolaryngologyThe Eighth Medical Center of Chinese PLA General HospitalBeijingChina
| |
Collapse
|
17
|
Stabenau K, Johnston N. How I Approach Laryngopharyngoesophageal Reflux (LPR). Curr Gastroenterol Rep 2021; 23:27. [PMID: 34799757 DOI: 10.1007/s11894-021-00823-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/24/2021] [Indexed: 12/12/2022]
Abstract
The purpose of this article is to review the cornerstone and most recent literature regarding laryngopharynoesophageal reflux (LPR) including epidemiological characteristics, pathophysiology, symptoms, diagnosis, and management. The role of pepsin in the pathophysiology of LPR is highlighted in addition to new diagnostic modalities and pharmacologic therapies that target pepsin.
Collapse
Affiliation(s)
- Kaleigh Stabenau
- Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA
| | - Nikki Johnston
- Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, 9200 W Wisconsin Ave, Milwaukee, WI, 53226, USA.
| |
Collapse
|
18
|
Sorafenib Repurposing for Ophthalmic Delivery by Lipid Nanoparticles: A Preliminary Study. Pharmaceutics 2021; 13:pharmaceutics13111956. [PMID: 34834371 PMCID: PMC8622456 DOI: 10.3390/pharmaceutics13111956] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 11/15/2021] [Accepted: 11/16/2021] [Indexed: 12/29/2022] Open
Abstract
Uveal melanoma is the second most common melanoma and the most common intraocular malignant tumour of the eye. Among various treatments currently studied, Sorafenib was also proposed as a promising drug, often administered with other compounds in order to avoid resistance mechanisms. Despite its promising cellular activities, the use of Sorafenib by oral administration is limited by its severe side effects and the difficulty to reach the target. The encapsulation into drug delivery systems represents an interesting strategy to overcome these limits. In this study, different lipid nanoparticulate formulations were prepared and compared in order to select the most suitable for the encapsulation of Sorafenib. In particular, two solid lipids (Softisan or Suppocire) at different concentrations were used to produce solid lipid nanoparticles, demonstrating that higher amounts were able to achieve smaller particle sizes, higher homogeneity, and longer physical stability. The selected formulations, which demonstrated to be biocompatible on Statens Seruminstitut Rabbit Cornea cells, were modified to improve their mucoadhesion, evaluating the effect of two monovalent cationic lipids with two lipophilic chains. Sorafenib encapsulation allowed obtaining a sustained and prolonged drug release, thus confirming the potential use of the developed strategy to topically administer Sorafenib in the treatment of uveal melanoma.
Collapse
|
19
|
Li S, Huang S, Ke Y, Chen H, Dang J, Huang C, Liu W, Cui D, Wang J, Zhi X, Ding X. A HiPAD Integrated with rGO/MWCNTs Nano-Circuit Heater for Visual Point-of-Care Testing of SARS-CoV-2. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2100801. [PMID: 34230825 PMCID: PMC8250055 DOI: 10.1002/adfm.202100801] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 03/19/2021] [Indexed: 05/03/2023]
Abstract
Nowadays, the main obstacle for further miniaturization and integration of nucleic acids point-of-care testing devices is the lack of low-cost and high-performance heating materials for supporting reliable nucleic acids amplification. Herein, reduced graphene oxide hybridized multi-walled carbon nanotubes nano-circuit integrated into an ingenious paper-based heater is developed, which is integrated into a paper-based analytical device (named HiPAD). The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is still raging across the world. As a proof of concept, the HiPAD is utilized to visually detect the SARS-CoV-2 N gene using colored loop-mediated isothermal amplification reaction. This HiPAD costing a few dollars has comparable detection performance to traditional nucleic acids amplifier costing thousands of dollars. The detection range is from 25 to 2.5 × 1010 copies mL-1 in 45 min. The detection limit of 25 copies mL-1 is 40 times more sensitive than 1000 copies mL-1 in conventional real-time PCR instruments. The disposable paper-based chip could also avoid potential secondary transmission of COVID-19 by convenient incineration to guarantee biosafety. The HiPAD or easily expanded M-HiPAD (for multiplex detection) has great potential for pathogen diagnostics in resource-limited settings.
Collapse
Affiliation(s)
- Sijie Li
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Shiyi Huang
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Yuqing Ke
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Hongjun Chen
- Shanghai Veterinary Research Institute518 Ziyue Road, Minhang DistrictShanghai200241China
| | - Jingqi Dang
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Chengjie Huang
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Wenjia Liu
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Daxiang Cui
- Shanghai Engineering Center for Intelligent Diagnosis and Treatment InstrumentSchool of Electronic Information and Electrical EngineeringShanghai Jiao Tong University800 Dongchuan RD, Minghang DistrictShanghai200240China
| | - Jinglin Wang
- State Key Laboratory of Pathogen and BiosecurityInstitute of Microbiology and Epidemiology20 Dongda Street, Fengtai DistrictBeijing100071China
| | - Xiao Zhi
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| | - Xianting Ding
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong University1954 Huashan RD, Xuhui DistrictShanghai200030China
| |
Collapse
|
20
|
Pepsin in gastroesophageal and extraesophageal reflux: molecular pathophysiology and diagnostic utility. Curr Opin Otolaryngol Head Neck Surg 2020; 28:401-409. [DOI: 10.1097/moo.0000000000000664] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
21
|
Yin CY, Zhang SS, Zhong JT, Zhou SH. Pepsin and Laryngeal and Hypopharyngeal Carcinomas. Clin Exp Otorhinolaryngol 2020; 14:159-168. [PMID: 32734742 PMCID: PMC8111387 DOI: 10.21053/ceo.2020.00465] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Accepted: 07/17/2020] [Indexed: 02/08/2023] Open
Abstract
Laryngeal and hypopharyngeal carcinomas are common malignant tumors of the head and neck, and the incidence of both is increasing. Laryngopharyngeal reflux refers to the retrograde flow of gastric contents into the larynx, oropharynx, and/or nasopharynx. It remains controversial whether laryngopharyngeal reflux is a risk factor for laryngeal and hypopharyngeal cancers. The refluxing substances mainly include hydrochloric acid, pepsin, and occasionally bile acids and bile salts, as well as bacteria that colonize the gastrointestinal tract. Loss of epithelium in the mucous membrane of the larynx and hypopharynx is thought to be caused by pepsin. Here, we review the relationships between laryngopharyngeal reflux and both laryngeal and hypopharyngeal carcinomas, as well as the significance of pepsin, methods of clinical detection, and the mechanism of carcinogenesis.
Collapse
Affiliation(s)
- Cheng-Yi Yin
- Department of Otolaryngology, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China.,Department of Otolaryngology, The First People's Hospital of Huzhou City, Zhejiang, China
| | - Sha-Sha Zhang
- Department of Otolaryngology, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Jiang-Tao Zhong
- Department of Otolaryngology, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Shui-Hong Zhou
- Department of Otolaryngology, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|