Ma Y, Song J, Zhao Y, Tanaka K, Wu S, Dong C, Wang X, Kanno I, Ouyang J, Zhou J, Liu Y. Excellent Uniformity and Properties of Micro-Meter Thick Lead Zirconate Titanate Coatings with Rapid Thermal Annealing. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3185. [PMID: 37110021 PMCID: PMC10142605 DOI: 10.3390/ma16083185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/15/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
Lead zirconate titanate (PZT) films have shown great potential in piezoelectric micro-electronic-mechanical system (piezo-MEMS) owing to their strong piezoelectric response. However, the fabrication of PZT films on wafer-level suffers with achieving excellent uniformity and properties. Here, we successfully prepared perovskite PZT films with similar epitaxial multilayered structure and crystallographic orientation on 3-inch silicon wafers, by introducing a rapid thermal annealing (RTA) process. Compared to films without RTA treatment, these films exhibit (001) crystallographic orientation at certain composition that expecting morphotropic phase boundary. Furthermore, dielectric, ferroelectric and piezoelectric properties on different positions only fluctuate within 5%. The relatively dielectric constant, loss, remnant polarization and transverse piezoelectric coefficient are 850, 0.1, 38 μC/cm2 and -10 C/m2, respectively. Both uniformity and properties have reached the requirement for the design and fabrication of piezo-MEMS devices. This broadens the design and fabrication criteria for piezo-MEMS, particularly for piezoelectric micromachined ultrasonic transducers.
Collapse
Affiliation(s)
- Youcao Ma
- State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 200433, China
| | - Jian Song
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yuyao Zhao
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Kiyotaka Tanaka
- Department of Mechanical Engineering, Kobe University, Kobe 657-8501, Japan
| | - Shijunbo Wu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chao Dong
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xubo Wang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Isaku Kanno
- Department of Mechanical Engineering, Kobe University, Kobe 657-8501, Japan
| | - Jun Ouyang
- School of Chemistry and Chemical Engineering, Qilu University of Technology, Jinan 250353, China;
| | - Jia Zhou
- State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 200433, China
| | - Yue Liu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
2
|
Chen Y, Wang Y, Lv T, Zhang J, Yu H. Single optical fiber based forward-viewing all-optical ultrasound self-transceiving probe. OPTICS LETTERS 2023; 48:868-871. [PMID: 36790962 DOI: 10.1364/ol.479718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 12/14/2022] [Indexed: 06/18/2023]
Abstract
All-optical ultrasound probes with fully integrated ultrasound generation and detection functions demonstrate some unique advantages over traditional electroacoustic counterparts. However, due to the lack of an effective solution, the most commonly used method is to assemble two separate functional optical fibers together for ultrasound generation and detection, respectively. In this Letter, an innovative strategy, to the best of our knowledge, is developed to integrate the photoacoustic effect based ultrasound generation and the Fabry-Pérot (FP) interference based ultrasound detection structures together at the end of a single double clad optical fiber (DCF), so as to make a compact forward-viewing ultrasound self-transceiving probe (1-mm diameter). From the experiment results, the as-fabricated probe can generate an ultrasound signal with an amplitude of 2.36 MPa at 2.25 mm in the transmitting mode, and its peak frequency and -6-dB bandwidth are measured to be 10.64 MHz and 22.93 MHz, respectively. When being operated under the receiving mode, the probe has a detection sensitivity of 208.4 mV/MPa for ultrasound signals with the peak frequency of 8.24 MHz, and the noise equivalent pressure (NEP) is 76.8 kPa. In addition, the forward-viewing format ultrasound self-transceiving experiment is also performed and the pulse-echo signal varying with the transmission distance is successfully captured for the first time.
Collapse
|
3
|
S A, Krishnan K, Arora M. Review of pMUTs for medical imaging: towards high frequency arrays. Biomed Phys Eng Express 2023; 9. [PMID: 36595267 DOI: 10.1088/2057-1976/acaab2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 12/12/2022] [Indexed: 12/14/2022]
Abstract
pMUT (piezoelectric Micromachined Ultrasound Transducer) devices are an alternative that can overcome the limitations associated with conventional ultrasound transducers. pMUT's are reported for many applications such as range-finding, biometrics, and ultrasound imaging. However, pulse-echo measurements from fabricated pMUT devices/arrays are not commonly reported in literature, a reason being lack of desirable performance either in transmit or receive mode of operation. There is also limited information about the design, fabrication and characterization of 2D-pMUT-arrays operating at high frequencies (>15 MHz) in water medium. In this paper we review 'state-of-the-art' for pMUT-array based medical ultrasound imaging, with a focus on their pulse-echo imaging capability. Over the next 3-5 years, we expect further improvement in piezoelectric thin film deposition techniques, on-chip integration of pre-amplification circuits and further miniaturization of pMUT devices, thus paving the way for development of pMUT-array based high frequency medical imaging systems.
Collapse
Affiliation(s)
- Atheeth S
- Centre for Product Design and Manufacturing (CPDM), Indian Institute of Science (IISc), India
| | - Kajoli Krishnan
- Centre for Product Design and Manufacturing (CPDM), Indian Institute of Science (IISc), India
| | - Manish Arora
- Centre for Product Design and Manufacturing (CPDM), Indian Institute of Science (IISc), India
| |
Collapse
|
4
|
He Y, Wan H, Jiang X, Peng C. Piezoelectric Micromachined Ultrasound Transducer Technology: Recent Advances and Applications. BIOSENSORS 2022; 13:bios13010055. [PMID: 36671890 PMCID: PMC9856188 DOI: 10.3390/bios13010055] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 05/14/2023]
Abstract
The objective of this article is to review the recent advancement in piezoelectric micromachined ultrasound transducer (PMUT) technology and the associated piezoelectric materials, device fabrication and characterization, as well as applications. PMUT has been an active research topic since the late 1990s because of the ultrasound application needs of low cost large 2D arrays, and the promising progresses on piezoelectric thin films, semiconductors, and micro/nano-electromechanical system technology. However, the industrial and medical applications of PMUTs have not been very significant until the recent success of PMUT based fingerprint sensing, which inspired growing interests in PMUT research and development. In this paper, recent advances of piezoelectric materials for PMUTs are reviewed first by analyzing the material properties and their suitability for PMUTs. PMUT structures and the associated micromachining processes are next reviewed with a focus on the complementary metal oxide semiconductor compatibility. PMUT prototypes and their applications over the last decade are then summarized to show the development trend of PMUTs. Finally, the prospective future of PMUTs is discussed as well as the challenges on piezoelectric materials, micro/nanofabrication and device integration.
Collapse
Affiliation(s)
- Yashuo He
- School of Biomedical Engineering, ShanghaiTech University, Shanghai 201210, China
| | - Haotian Wan
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Correspondence: (X.J.); (C.P.)
| | - Chang Peng
- School of Biomedical Engineering, ShanghaiTech University, Shanghai 201210, China
- Correspondence: (X.J.); (C.P.)
| |
Collapse
|
5
|
Birjis Y, Swaminathan S, Nazemi H, Raj GCA, Munirathinam P, Abu-Libdeh A, Emadi A. Piezoelectric Micromachined Ultrasonic Transducers (PMUTs): Performance Metrics, Advancements, and Applications. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22239151. [PMID: 36501852 PMCID: PMC9738559 DOI: 10.3390/s22239151] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 11/16/2022] [Accepted: 11/22/2022] [Indexed: 05/27/2023]
Abstract
With the development of technology, systems gravitate towards increasing in their complexity, miniaturization, and level of automation. Amongst these systems, ultrasonic devices have adhered to this trend of advancement. Ultrasonic systems require transducers to generate and sense ultrasonic signals. These transducers heavily impact the system's performance. Advancements in microelectromechanical systems have led to the development of micromachined ultrasonic transducers (MUTs), which are utilized in miniaturized ultrasound systems. Piezoelectric micromachined ultrasonic transducers (PMUTs) exhibit higher capacitance and lower electrical impedance, which enhances the transducer's sensitivity by minimizing the effect of parasitic capacitance and facilitating their integration with low-voltage electronics. PMUTs utilize high-yield batch microfabrication with the use of thin piezoelectric films. The deposition of thin piezoelectric material compatible with complementary metal-oxide semiconductors (CMOS) has opened novel avenues for the development of miniaturized compact systems with the same substrate for application and control electronics. PMUTs offer a wide variety of applications, including medical imaging, fingerprint sensing, range-finding, energy harvesting, and intrabody and underwater communication links. This paper reviews the current research and recent advancements on PMUTs and their applications. This paper investigates in detail the important transduction metrics and critical design parameters for high-performance PMUTs. Piezoelectric materials and microfabrication processes utilized to manufacture PMUTs are discussed. Promising PMUT applications and outlook on future advancements are presented.
Collapse
|
6
|
Nguyen TP, Choi J, Nguyen VT, Mondal S, Bui NT, Vu DD, Park S, Oh J. Design and Micro-Fabrication of Focused High-Frequency Needle Transducers for Medical Imaging. SENSORS (BASEL, SWITZERLAND) 2022; 22:3763. [PMID: 35632172 PMCID: PMC9143298 DOI: 10.3390/s22103763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 05/09/2022] [Accepted: 05/13/2022] [Indexed: 01/25/2023]
Abstract
In this study, we report an advanced fabrication technique to develop a miniature focused needle transducer. Two different types of high-frequency (100 MHz) transducers were fabricated using the lead magnesium niobate-lead titanate (PMN-0.3PT) and lithium niobate (LiNbO3) single crystals. In order to enhance the transducer's performance, a unique mass-spring matching layer technique was adopted, in which gold and parylene play the roles of the mass layer and spring layer, respectively. The PMN-0.3PT transducer had a 103 MHz center frequency with a -6 dB bandwidth of 52%, and a signal-to-noise ratio (SNR) of 42 dB. The center frequency, -6 dB bandwidth, and SNR of the LiNbO3 transducer were 105 MHz, 66%, and 44 dB, respectively. In order to compare and evaluate the transducers' performances, an ultrasonic biomicroscopy (UBM) imaging on the fish eye was performed. The results showed that the LiNbO3 transducer had a better contrast resolution compared to the PMN-0.3PT transducer. The fabricated transducer showed an excellent performance with high-resolution corneal epithelium imaging of the experimental fish eye. These interesting findings are useful for the future biomedical implementation of the fabricated transducers in the field of high-resolution ultrasound imaging and diagnosis purpose.
Collapse
Affiliation(s)
- Thanh Phuoc Nguyen
- Department of Mechatronics, Cao Thang Technical College, Ho Chi Minh City 700000, Vietnam
| | - Jaeyeop Choi
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (J.C.); (V.T.N.); (D.D.V.); (S.P.); (J.O.)
| | - Van Tu Nguyen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (J.C.); (V.T.N.); (D.D.V.); (S.P.); (J.O.)
| | - Sudip Mondal
- New-Senior Healthcare Innovation Center (BK21 Plus), Pukyong National University, Busan 48513, Korea;
| | - Ngoc Thang Bui
- Institute of Engineering, HUTECH University, Ho Chi Minh City 700000, Vietnam;
| | - Dinh Dat Vu
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (J.C.); (V.T.N.); (D.D.V.); (S.P.); (J.O.)
| | - Sumin Park
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (J.C.); (V.T.N.); (D.D.V.); (S.P.); (J.O.)
| | - Junghwan Oh
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (J.C.); (V.T.N.); (D.D.V.); (S.P.); (J.O.)
- New-Senior Healthcare Innovation Center (BK21 Plus), Pukyong National University, Busan 48513, Korea;
- Ohlabs Corporation, Busan 48513, Korea
| |
Collapse
|
7
|
Li P, Fan Z, Duan X, Cui D, Zang J, Zhang Z, Xue C. Enhancement of the Transmission Performance of Piezoelectric Micromachined Ultrasound Transducers by Vibration Mode Optimization. MICROMACHINES 2022; 13:mi13040596. [PMID: 35457901 PMCID: PMC9028921 DOI: 10.3390/mi13040596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 11/16/2022]
Abstract
Ultrasound is widely used in industry and the agricultural, biomedical, military, and other fields. As key components in ultrasonic applications, the characteristic parameters of ultrasonic transducers fundamentally determine the performance of ultrasonic systems. High-frequency ultrasonic transducers are small in size and require high precision, which puts forward higher requirements for sensor design, material selection, and processing methods. In this paper, a three-dimensional model of a high-frequency piezoelectric micromachined ultrasonic transducer (PMUT) is established based on the finite element method (FEM). This 3D model consists of a substrate, a silicon device layer, and a molybdenum-aluminum nitride-molybdenum (Mo-AlN-Mo) sandwich piezoelectric layer. The effect of the shape of the transducer’s vibrating membrane on the transmission performance was studied. Through a discussion of the parametric scanning of the key dimensions of the diaphragms of the three structures, it was concluded that the fundamental resonance frequency of the hexagonal diaphragm was higher than that of the circle and the square under the same size. Compared with the circular diaphragm, the sensitivity of the square diaphragm increased by 8.5%, and the sensitivity of the hexagonal diaphragm increased by 10.7%. The maximum emission sound-pressure level of the hexagonal diaphragm was 6.6 times higher than that of the circular diaphragm. The finite element results show that the hexagonal diaphragm design has great advantages for improving the transmission performance of the high-frequency PMUT.
Collapse
|
8
|
Zhu W, Wang L, Wu Z, Liu W, Sun C. Broadband Piezoelectric Micromachined Ultrasonic Transducer With a Resonant Cavity. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:340-349. [PMID: 34665723 DOI: 10.1109/tuffc.2021.3119669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
This article presents a broadband piezoelectric micromachined ultrasonic transducer (PMUT) surrounded by a resonant cavity called C-PMUT. The C-PMUT shows two resonance peaks derived from the resonances of the active PMUT cell and the passive resonant cavity. Both of the two resonances vibrate at the first-order resonant mode. An equivalent circuit model is established considering the vibration of the resonant cavity and the crosstalk between the PMUT cell and the resonant cavity. Finite element analysis (FEA) has been used to verify the theoretical model. Bandwidth optimization has been operated and the -6 dB bandwidth is extended to more than 100% in liquid. Furthermore, the theoretical model of the C-PMUT array is established based on the C-PMUT cell. The FEA models of the C-PMUT arrays are proposed, and the -6 dB bandwidth of a 4 ×4 C-PMUT array is increased to 2× compared to the traditional array. Therefore, the C-PMUT provides a novel broadband strategy for future real-time ultrasound imaging.
Collapse
|
9
|
Jiang X, Perrot V, Varray F, Bart S, Hartwell PG. Piezoelectric Micromachined Ultrasonic Transducer for Arterial Wall Dynamics Monitoring. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:291-298. [PMID: 34648440 DOI: 10.1109/tuffc.2021.3120283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this article, a [Formula: see text] piezoelectric micromachined ultrasonic transducer (PMUT) array is designed and driven with one cycle of a 5-MHz sinusoid at 10 [Formula: see text] for radial artery motion tracking. The transmit and receive performance figure of merit (FOM) of an individual PMUT over operating frequency is modeled and validated using laser Doppler vibrometer (LDV) measurements. Given a fixed cross section, the FOM inversely scales with frequency. The array aperture size is selected to obtain enough pressure and received signal to measure the radial artery wall reflection at a 5-mm depth in tissue. The 2-mm acoustic beamwidth provides enough lateral resolution for radial artery wall motion tracking. Single-line ultrasonic pulse-echo measurements with high time resolution, also called M-mode ultrasound imaging, are demonstrated to reproduce a known target motion profile with a precision of around 0.5 [Formula: see text]. In vivo radial artery dynamics are measured by placing the sensor on the wrist of a volunteer. The measured diameter change waveform of the radial artery is consistent with reports in the literature and captures key arterial pulse waveform features, including systolic upstroke, systolic decline, dicrotic notch, and diastolic runoff. The system has sufficient accuracy and precision to measure both the 50 [Formula: see text] overall diameter change and the 5- [Formula: see text] diameter change due to the dicrotic notch. A heart rate of 70 beats/min is also derived. This demonstrates the great potential of custom PMUT arrays for continuous cardiovascular system monitoring.
Collapse
|
10
|
Ledesma E, Zamora I, Uranga A, Torres F, Barniol N. Enhancing AlN PMUTs' Acoustic Responsivity within a MEMS-on-CMOS Process. SENSORS 2021; 21:s21248447. [PMID: 34960541 PMCID: PMC8705788 DOI: 10.3390/s21248447] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 12/10/2021] [Accepted: 12/14/2021] [Indexed: 01/07/2023]
Abstract
In this paper, guidelines for the optimization of piezoelectrical micromachined ultrasound transducers (PMUTs) monolithically integrated over a CMOS technology are developed. Higher acoustic pressure is produced by PMUTs with a thin layer of AlN piezoelectrical material and Si3N4 as a passive layer, as is studied here with finite element modeling (FEM) simulations and experimental characterization. Due to the thin layers used, parameters such as residual stress become relevant as they produce a buckled structure. It has been reported that the buckling of the membrane due to residual stress, in general, reduces the coupling factor and consequently degrades the efficiency of the acoustic pressure production. In this paper, we show that this buckling can be beneficial and that the fabricated PMUTs exhibit enhanced performance depending on the placement of the electrodes. This behavior was demonstrated experimentally and through FEM. The acoustic characterization of the fabricated PMUTs shows the enhancement of the PMUT performance as a transmitter (with 5 kPa V−1 surface pressure for a single PMUT) and as a receiver (12.5 V MPa−1) in comparison with previously reported devices using the same MEMS-on-CMOS technology as well as state-of-the-art devices.
Collapse
|
11
|
Design of 2D Planar Sparse Binned Arrays Based on the Coarray Analysis. SENSORS 2021; 21:s21238018. [PMID: 34884023 PMCID: PMC8659468 DOI: 10.3390/s21238018] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/24/2021] [Accepted: 11/28/2021] [Indexed: 11/17/2022]
Abstract
The analysis of the beampattern is the base of sparse arrays design process. However, in the case of bidimensional arrays, this analysis has a high computational cost, turning the design process into a long and complex task. If the imaging system development is considered a holistic process, the aperture is a sampling grid that must be considered in the spatial domain through the coarray structure. Here, we propose to guide the aperture design process using statistical parameters of the distribution of the weights in the coarray. We have studied three designs of sparse matrix binned arrays with different sparseness degrees. Our results prove that there is a relationship between these parameters and the beampattern, which is valuable and improves the array design process. The proposed methodology reduces the computational cost up to 58 times with respect to the conventional fitness function based on the beampattern analysis.
Collapse
|
12
|
Barakat MAY, El-Wakil AEAA. Preparation and characterization of EVA/ZnO composites as piezoelectric elements for ultrasonic transducers. MATERIALS RESEARCH EXPRESS 2021; 8:105304. [DOI: 10.1088/2053-1591/ac29fb] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|