1
|
Yang H, Rong C, Ge S, Wang T, Zhang B, Xuan FZ. Copper Nanoclusters Anchored on Crumpled N-Doped MXene for Ultra-Sensitive Electrochemical Sensing. SENSORS (BASEL, SWITZERLAND) 2025; 25:2508. [PMID: 40285194 PMCID: PMC12031129 DOI: 10.3390/s25082508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2025] [Revised: 04/09/2025] [Accepted: 04/14/2025] [Indexed: 04/29/2025]
Abstract
Simultaneous detection of dopamine (DA) and uric acid (UA) is essential for diagnosing neurological and metabolic diseases but hindered by overlapping electrochemical signals. We present an ultrasensitive electrochemical sensor using copper nanoclusters anchored on nitrogen-doped crumpled Ti3C2Tx MXene (Cu-N/Ti3C2Tx). The engineered 3D crumpled architecture prevents MXene restacking, exposes active sites, and enhances ion transport, while Cu nanoclusters boost electrocatalytic activity via accelerated electron transfer. Structural analyses confirm uniform Cu dispersion (3.0 wt%), Ti-N bonding, and strain-induced wrinkles, synergistically improving conductivity. The sensor achieves exceptional sensitivity (1958.3 and 1152.7 μA·mM-1·cm-2 for DA/UA), ultralow detection limits (0.058 and 0.099 μM for DA/UA), rapid response (<1.5 s), and interference resistance (e.g., ascorbic acid). Differential pulse voltammetry enables independent linear detection ranges (DA: 2-60 μM; UA: 5-100 μM) in biofluids, with 94.4% stability retention over 7 days. The designed sensor exhibits excellent capabilities for DA and UA detection. This work provides a novel design strategy for developing high-performance electrochemical sensors.
Collapse
Affiliation(s)
- Hanxue Yang
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Chao Rong
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Shundong Ge
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Tao Wang
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Bowei Zhang
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Fu-Zhen Xuan
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai 200237, China; (H.Y.); (C.R.); (S.G.)
- Key Laboratory of Pressure Systems and Safety of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China
| |
Collapse
|
2
|
Wang J, Kan C, Jin B. Highly sensitive electrochemical biosensor for MUC1 detection based on DNA-functionalized CdTe quantum dots as signal enhancers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:7806-7815. [PMID: 39421884 DOI: 10.1039/d4ay01544d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
In this paper, an electrochemical biosensor based on a cadmium telluride/polypyrrole (CdTe/PPy) nanocomposite was developed for the detection of MUC1 with high selectivity and sensitivity. Results indicate that the CdTe/PPy nanocomposite is modified on the surface of the glassy carbon electrode (GCE), which affords a large surface area for immobilizing cap-DNA, ensuring its high selectivity and sensitivity. Next, CdTe-linked sig-DNA (MUC1 aptamer) was introduced, allowing the MUC1 aptamer to hybridize with cap-DNA. CdTe is a signal amplification element used to generate a differential pulse voltammetry (DPV) signal. Conceivably, target MUC1 detection was based on current signal change due to concentration change in the signal amplification element CdTe. In the presence of MUC1, the MUC1 aptamer specifically binds to MUC1, resulting in the release of CdTe-sig-DNA from the electrode surface and a decrease in peak current. Under optimized experimental conditions, the electrochemical biosensor is highly selective, sensitive, stable, and reproducible for MUC1 ranging from 0.1 nM to 100 nM with a detection limit of 0.05 nM (S/N = 3). Therefore, the electrochemical biosensor has potential applications in medical disease diagnosis.
Collapse
Affiliation(s)
- JiaJia Wang
- Department of Chemistry, Anhui University, Hefei 230601, China
- School of Materials Science and Chemical Engineering, ChuZhou University, ChuZhou 239200, China
| | - Chun Kan
- Department of Chemistry, Anhui University, Hefei 230601, China
- School of Materials Science and Chemical Engineering, ChuZhou University, ChuZhou 239200, China
| | - Baokang Jin
- Department of Chemistry, Anhui University, Hefei 230601, China
| |
Collapse
|
3
|
Ramadoss J, Sonachalam A, Yusuf K, Govindasamy M. Intercalation of multilayered Ti 3C 2T x electrode doped with vanadium for highly sensitive electrochemical detection of dopamine in biological samples. Mikrochim Acta 2024; 191:613. [PMID: 39305316 DOI: 10.1007/s00604-024-06653-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Accepted: 08/24/2024] [Indexed: 09/25/2024]
Abstract
The electrochemical detection characteristics of the layered Ti3C2Tx material were enhanced by modifying its surface. Ti3C2Tx is used as the Ti - F chemical bond weakens with increasing pH levels. Ti3C2Tx is alkalinized by KOH, and F is substituted for - OH. The surface hydroxyl groups can be eliminated by intercalating K+. This study elaborates on the hydrothermal production of vanadium-doped layered Ti3C2Tx nanosheets intercalated with K+. The development of a sensitive dopamine electrochemical sensor is outlined by intercalating a vanadium-doped multilayered K+ Ti3C2Tx electrode. The chemical, surface, and structural composition of the synthesized electrode for dopamine detection was investigated and confirmed. The sensor exhibits a linear range (1-10 µM), a low detection limit (8.4 nM), and a high sensitivity of 2.746 µAµM-1cm-2 under optimal electrochemical testing conditions. The sensor also demonstrates exceptional anti-interference capabilities and stability. The sensor was applied to detection of dopamine in (spiked) rat brains, human serum, and urine samples. This study introduces a novel approach by utilizing K+ intercalation of vanadium-doped Ti3C2Tx-based electrochemical sensors and an innovative method for dopamine detection. The dopamine detection revealed the potential of (V0.05) K+ Ti3C2Tx-GCE for practical application in pharmaceutical sample analysis.
Collapse
Affiliation(s)
- Jagadeesh Ramadoss
- Centre for High-Pressure Research, School of Physics, Bharathidasan University, Tiruchirappalli, 620024, Tamil Nadu, India
- International Ph.D. Program in Innovative Technology of Biomedical Engineering and Medical Devices, Ming Chi University of Technology, New Taipei City, 24301, Taiwan
| | - Arumugam Sonachalam
- Centre for High-Pressure Research, School of Physics, Bharathidasan University, Tiruchirappalli, 620024, Tamil Nadu, India.
- Tamil Nadu Open University, Chennai, 600015, India.
| | - Kareem Yusuf
- Department of Chemistry, College of Science, King Saud University, Riyadh, 11451, Saudi Arabia
| | - Mani Govindasamy
- International Ph.D. Program in Innovative Technology of Biomedical Engineering and Medical Devices, Ming Chi University of Technology, New Taipei City, 24301, Taiwan.
- Research Center for Intelligence Medical Devices, Ming Chi University of Technology, New Taipei City, 243303, Taiwan.
- Centre for Applied Research, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai, 602105, Tamil Nadu, India.
| |
Collapse
|
4
|
Jia D, Yang T, Wang K, Wang H, Wang E, Chou KC, Hou X. Ti 3C 2T x Coated with TiO 2 Nanosheets for the Simultaneous Detection of Ascorbic Acid, Dopamine and Uric Acid. Molecules 2024; 29:2915. [PMID: 38930980 PMCID: PMC11206739 DOI: 10.3390/molecules29122915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/13/2024] [Accepted: 06/16/2024] [Indexed: 06/28/2024] Open
Abstract
Two-dimensional MXenes have become an important material for electrochemical sensing of biomolecules due to their excellent electric properties, large surface area and hydrophilicity. However, the simultaneous detection of multiple biomolecules using MXene-based electrodes is still a challenge. Here, a simple solvothermal process was used to synthesis the Ti3C2Tx coated with TiO2 nanosheets (Ti3C2Tx@TiO2 NSs). The surface modification of TiO2 NSs on Ti3C2Tx can effectively reduce the self-accumulation of Ti3C2Tx and improve stability. Glassy carbon electrode was modified by Ti3C2Tx@TiO2 NSs (Ti3C2Tx@TiO2 NSs/GCE) and was able simultaneously to detect dopamine (DA), ascorbic acid (AA) and uric acid (UA). Under concentrations ranging from 200 to 1000 μM, 40 to 300 μM and 50 to 400 μM, the limit of detection (LOD) is 2.91 μM, 0.19 μM and 0.25 μM for AA, DA and UA, respectively. Furthermore, Ti3C2Tx@TiO2 NSs/GCE demonstrated remarkable stability and reliable reproducibility for the detection of AA/DA/UA.
Collapse
Affiliation(s)
- Dengzhou Jia
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
| | - Tao Yang
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
- Institute of Steel Sustainable Technology, Liaoning Academy of Materials, Shenyang 110167, China
| | - Kang Wang
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
| | - Hongyang Wang
- State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
| | - Enhui Wang
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
- Institute of Steel Sustainable Technology, Liaoning Academy of Materials, Shenyang 110167, China
| | - Kuo-Chih Chou
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
| | - Xinmei Hou
- Institute for Carbon Neutrality, University of Science and Technology Beijing, Beijing 100083, China
- Institute of Steel Sustainable Technology, Liaoning Academy of Materials, Shenyang 110167, China
- Beijing Advanced Innovation Center for Materials Genome Engineering, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
5
|
Kuntoji G, Kousar N, Gaddimath S, Koodlur Sannegowda L. Macromolecule-Nanoparticle-Based Hybrid Materials for Biosensor Applications. BIOSENSORS 2024; 14:277. [PMID: 38920581 PMCID: PMC11201996 DOI: 10.3390/bios14060277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/21/2024] [Accepted: 04/26/2024] [Indexed: 06/27/2024]
Abstract
Biosensors function as sophisticated devices, converting biochemical reactions into electrical signals. Contemporary emphasis on developing biosensor devices with refined sensitivity and selectivity is critical due to their extensive functional capabilities. However, a significant challenge lies in the binding affinity of biosensors to biomolecules, requiring adept conversion and amplification of interactions into various signal modalities like electrical, optical, gravimetric, and electrochemical outputs. Overcoming challenges associated with sensitivity, detection limits, response time, reproducibility, and stability is essential for efficient biosensor creation. The central aspect of the fabrication of any biosensor is focused towards forming an effective interface between the analyte electrode which significantly influences the overall biosensor quality. Polymers and macromolecular systems are favored for their distinct properties and versatile applications. Enhancing the properties and conductivity of these systems can be achieved through incorporating nanoparticles or carbonaceous moieties. Hybrid composite materials, possessing a unique combination of attributes like advanced sensitivity, selectivity, thermal stability, mechanical flexibility, biocompatibility, and tunable electrical properties, emerge as promising candidates for biosensor applications. In addition, this approach enhances the electrochemical response, signal amplification, and stability of fabricated biosensors, contributing to their effectiveness. This review predominantly explores recent advancements in utilizing macrocyclic and macromolecular conjugated systems, such as phthalocyanines, porphyrins, polymers, etc. and their hybrids, with a specific focus on signal amplification in biosensors. It comprehensively covers synthetic strategies, properties, working mechanisms, and the potential of these systems for detecting biomolecules like glucose, hydrogen peroxide, uric acid, ascorbic acid, dopamine, cholesterol, amino acids, and cancer cells. Furthermore, this review delves into the progress made, elucidating the mechanisms responsible for signal amplification. The Conclusion addresses the challenges and future directions of macromolecule-based hybrids in biosensor applications, providing a concise overview of this evolving field. The narrative emphasizes the importance of biosensor technology advancement, illustrating the role of smart design and material enhancement in improving performance across various domains.
Collapse
Affiliation(s)
| | | | | | - Lokesh Koodlur Sannegowda
- Department of Studies in Chemistry, Vijayanagara Sri Krishnadevaraya University, Jnanasagara, Vinayakanagara, Ballari 583105, India; (G.K.); (N.K.); (S.G.)
| |
Collapse
|
6
|
Pattan-Siddappa G, Ko HU, Kim SY. Active site rich MXene as a sensing interface for brain neurotransmitter's and pharmaceuticals: One decade, many sensors. Trends Analyt Chem 2023; 164:117096. [DOI: 10.1016/j.trac.2023.117096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/23/2024]
|
7
|
Yang M, Wang L, Lu H, Dong Q. Advances in MXene-Based Electrochemical (Bio)Sensors for Neurotransmitter Detection. MICROMACHINES 2023; 14:mi14051088. [PMID: 37241710 DOI: 10.3390/mi14051088] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 05/14/2023] [Accepted: 05/18/2023] [Indexed: 05/28/2023]
Abstract
Neurotransmitters are chemical messengers that play an important role in the nervous system's control of the body's physiological state and behaviour. Abnormal levels of neurotransmitters are closely associated with some mental disorders. Therefore, accurate analysis of neurotransmitters is of great clinical importance. Electrochemical sensors have shown bright application prospects in the detection of neurotransmitters. In recent years, MXene has been increasingly used to prepare electrode materials for fabricating electrochemical neurotransmitter sensors due to its excellent physicochemical properties. This paper systematically introduces the advances in MXene-based electrochemical (bio)sensors for the detection of neurotransmitters (including dopamine, serotonin, epinephrine, norepinephrine, tyrosine, NO, and H2S), with a focus on their strategies for improving the electrochemical properties of MXene-based electrode materials, and provides the current challenges and future prospects for MXene-based electrochemical neurotransmitter sensors.
Collapse
Affiliation(s)
- Meiqing Yang
- Zoology Key Laboratory of Hunan Higher Education, College of Life and Environmental Science, Hunan University of Arts and Science, Changde 415000, China
| | - Lu Wang
- Institute of Chemical Biology and Nanomedicine (ICBN), State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
| | - Haozi Lu
- Institute of Chemical Biology and Nanomedicine (ICBN), State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
| | - Qizhi Dong
- Institute of Chemical Biology and Nanomedicine (ICBN), State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
| |
Collapse
|
8
|
He H, Guo Z. Fabric-based superhydrophobic MXene@ polypyrrole heater with superior dual-driving energy conversion. J Colloid Interface Sci 2023; 629:508-521. [DOI: 10.1016/j.jcis.2022.08.176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 11/26/2022]
|
9
|
Adekoya G, Adekoya OC, Sadiku RE, Hamam Y, Ray SS. Applications of MXene-Containing Polypyrrole Nanocomposites in Electrochemical Energy Storage and Conversion. ACS OMEGA 2022; 7:39498-39519. [PMID: 36385802 PMCID: PMC9648120 DOI: 10.1021/acsomega.2c02706] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
The atomically thick two-dimensional (2D) materials are at the forefront of revolutionary technologies for energy storage devices. Due to their fascinating physical and chemical features, these materials have gotten a lot of attention. They are particularly appealing for a wide range of applications, including electrochemical storage systems, due to their simplicity of property tuning. The MXene is a type of 2D material that is widely recognized for its exceptional electrochemical characteristics. The use of these materials in conjunction with conducting polymers, notably polypyrrole (PPy), has opened new possibilities for lightweight, flexible, and portable electrodes. Therefore, herein we report a comprehensive review of recent achievements in the production of MXene/PPy nanocomposites. The structural-property relationship of this class of nanocomposites was taken into consideration with an elaborate discussion of the various characterizations employed. As a result, this research gives a narrative explanation of how PPy interacts with distinct MXenes to produce desirable high-performance nanocomposites. The effects of MXene incorporation on the thermal, electrical, and electrochemical characteristics of the resultant nanocomposites were discussed. Finally, it is critically reviewed and presented as an advanced composite material in electrochemical storage devices, energy conversion, electrochemical sensors, and electromagnetic interference shielding.
Collapse
Affiliation(s)
- Gbolahan
Joseph Adekoya
- Institute
of Nanoengineering Research (INER) and Department of Chemical, Metallurgical
and Materials Engineering, Faculty of Engineering and the Built Environment, Tshwane University of Technology, Pretoria 0001, South Africa
- Centre
for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology
Innovation Centre, Council for Scientific
and Industrial Research, CSIR, Pretoria 0001, South Africa
| | - Oluwasegun Chijioke Adekoya
- Institute
of Nanoengineering Research (INER) and Department of Chemical, Metallurgical
and Materials Engineering, Faculty of Engineering and the Built Environment, Tshwane University of Technology, Pretoria 0001, South Africa
| | - Rotimi Emmanuel Sadiku
- Institute
of Nanoengineering Research (INER) and Department of Chemical, Metallurgical
and Materials Engineering, Faculty of Engineering and the Built Environment, Tshwane University of Technology, Pretoria 0001, South Africa
| | - Yskandar Hamam
- Department
of Electrical Engineering, Faculty of Engineering and the Built Environment, Tshwane University of Technology, Pretoria 0001, South Africa
- École
Supérieure d’Ingénieurs en Électrotechnique
et Électronique, Cité Descartes, 2 Boulevard Blaise Pascal, 93160 Noisy-le-Grand, Paris, France
| | - Suprakas Sinha Ray
- Centre
for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology
Innovation Centre, Council for Scientific
and Industrial Research, CSIR, Pretoria 0001, South Africa
- Department
of Chemical Sciences, University of Johannesburg, Doornforntein, Johannesburg 2028, South Africa
| |
Collapse
|
10
|
Rizwan K, Rahdar A, Bilal M, Iqbal HMN. MXene-based electrochemical and biosensing platforms to detect toxic elements and pesticides pollutants from environmental matrices. CHEMOSPHERE 2022; 291:132820. [PMID: 34762881 DOI: 10.1016/j.chemosphere.2021.132820] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 10/22/2021] [Accepted: 11/05/2021] [Indexed: 02/05/2023]
Abstract
Fabricating new biosensing constructs with high selectivity and sensitivity is the most needed environmental detection tool. In this context, several nanostructured materials have been envisaged to construct biosensors to achieve superior selectivity and sensitivity. Among them, MXene is regarded as the most promising to develop biosensors due to its fascinating attributes, like high surface area, excellent thermal resistance, good hydrophilicity, unique layered topology, high electrical conductivity, and environmentally-friendlier properties. MXenes-based materials have emerged as a prospective for catalysis, energy storage, electronics, and environmental sensing and remediation applications thanks to the above-mentioned exceptional characteristics. This review elaborates on the contemporary and state-of-the-art advancements in MXene-based electrochemical and biosensing tools to detect toxic elements, pharmaceutically active residues, and pesticide contaminants from environmental matrices. At first, the surface functionalization/modification of MXenes is discussed. Afterwards, a particular focus has been devoted to exploiting MXene to construct electrochemical (bio) sensors to detect various environmentally-related pollutants. Lastly, current challenges in this arena accompanied by potential solutions and directions are also outlined.
Collapse
Affiliation(s)
- Komal Rizwan
- Department of Chemistry, University of Sahiwal, Sahiwal, 57000, Pakistan
| | - Abbas Rahdar
- Department of Physics, University of Zabol, Zabol, P.O. Box. 35856-98613, Iran
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huai'an, 223003, China.
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey, 64849, Mexico.
| |
Collapse
|
11
|
Effect of graphite oxide and exfoliated graphite oxide as a modifier for the voltametric determination of dopamine in presence of uric acid and folic acid. Sci Rep 2021; 11:24040. [PMID: 34911963 PMCID: PMC8674362 DOI: 10.1038/s41598-021-01328-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 10/08/2021] [Indexed: 11/23/2022] Open
Abstract
In the present work, exfoliated graphite oxide (E-GO) was prepared by sonicating graphite oxide (GO) (prepared by modified Hummer's and Offemam methods). Prepared GO and E-GO were characterized using infrared absorption spectroscopy, X-ray diffraction, and scanning electron microscopy. The electrocatalytic properties of GO and E-GO towards detection of dopamine (DA), uric acid (UA), and folic acid (FA) were investigated using cyclic voltammetry and differential pulse voltammetry. Our results revealed that E-GO has a slighter advantage over the GO as an electrode modifier for detection DA, UA, and FA, which might be ascribed to the good conductivity of E-GO when compared to the GO.
Collapse
|
12
|
Thirumalai D, Lee S, Kwon M, Paik HJ, Lee J, Chang SC. Disposable Voltammetric Sensor Modified with Block Copolymer-Dispersed Graphene for Simultaneous Determination of Dopamine and Ascorbic Acid in Ex Vivo Mouse Brain Tissue. BIOSENSORS-BASEL 2021; 11:bios11100368. [PMID: 34677324 PMCID: PMC8534151 DOI: 10.3390/bios11100368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 09/26/2021] [Accepted: 09/30/2021] [Indexed: 12/02/2022]
Abstract
Dopamine (DA) and ascorbic acid (AA) are two important biomarkers with similar oxidation potentials. To facilitate their simultaneous electrochemical detection, a new voltammetric sensor was developed by modifying a screen-printed carbon electrode (SPCE) with a newly synthesized block copolymer (poly(DMAEMA-b-styrene), PDbS) as a dispersant for reduced graphene oxide (rGO). The prepared PDbS–rGO and the modified SPCE were characterized using a range of physical and electrochemical techniques including Raman spectroscopy, scanning electron microscopy, transmission electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and linear sweep voltammetry. Compared to the bare SPCE, the PDbS–rGO-modified SPCE (PDbS–rGO/SPCE) showed better sensitivity and peak-to-peak separation for DA and AA in mixed solutions. Under the optimum conditions, the dynamic linear ranges for DA and AA were 0.1–300 and 10–1100 µM, and the detection limits were 0.134 and 0.88 µM (S/N = 3), respectively. Furthermore, PDbS–rGO/SPCE exhibited considerably enhanced anti-interference capability, high reproducibility, and storage stability for four weeks. The practical potential of the PDbS–rGO/SPCE sensor for measuring DA and AA was demonstrated using ex vivo brain tissues from a Parkinson’s disease mouse model and the control.
Collapse
Affiliation(s)
- Dinakaran Thirumalai
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Korea;
| | - Seulah Lee
- College of Pharmacy, Pusan National University, Busan 46241, Korea; (S.L.); (J.L.)
| | - Minho Kwon
- Department of Polymer Science and Engineering, Pusan National University, Busan 46241, Korea; (M.K.); (H.-j.P.)
| | - Hyun-jong Paik
- Department of Polymer Science and Engineering, Pusan National University, Busan 46241, Korea; (M.K.); (H.-j.P.)
| | - Jaewon Lee
- College of Pharmacy, Pusan National University, Busan 46241, Korea; (S.L.); (J.L.)
| | - Seung-Cheol Chang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Korea;
- Correspondence:
| |
Collapse
|