1
|
Mugnai G, Cecchini F, Stroker E, Paparella G, Iacopino S, Sieira J, De Greef Y, Tomasi L, Bolzan B, Bala G, Overeinder I, Almorad A, Gauthey A, Sorgente A, Ribichini FL, de Asmundis C, Chierchia GB. Pulmonary vein size is associated with reconnection following cryoballoon ablation of atrial fibrillation. J Interv Card Electrophysiol 2022; 65:717-724. [PMID: 35930128 DOI: 10.1007/s10840-022-01330-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 08/01/2022] [Indexed: 12/13/2022]
Abstract
BACKGROUND The second-generation cryoballoon (CB) has proven to be a highly effective ablative strategy in patients with symptomatic atrial fibrillation (AF). This study sought to investigate the anatomical characteristics of pulmonary veins (PVs) and the relationship between their size, ovality, and late reconnections in a large cohort of patients undergoing repeat ablation for recurrence of atrial arrhythmias. METHODS AND RESULTS A total of 152 consecutive patients (98 males, 64.5%; mean age 64.9 ± 9.6 years) underwent a repeat ablation for recurrent atrial tachyarrhythmias after a median time of 6.5 months [IQR 11] from the index CB ablation. All repeat ablations were performed using a 3-dimensional electro-anatomical mapping system. Among all 593 PVs, 134 (22.6%) showed a late PV reconnection in 95 patients (0.88 per patient), at the time of repeat ablation procedure. There was a significant difference in ovality between left- and right-sided PVs (p < 0.001). Greater diameters of left superior PV, left inferior PV, and right inferior PV ostia (both maximum and minimum) and higher index ovality were significantly associated with late PV reconnection. CONCLUSIONS The rate of late PV reconnection after CB ablation was low (0.88 PVs/patient). Left-sided PVs were more oval than septal PVs. Larger PV dimensions and higher ovality index were significantly associated with reconnections in all PVs except for RSPV.
Collapse
Affiliation(s)
- Giacomo Mugnai
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium. .,Electrophysiology and Cardiac Pacing, Division of Cardiology, Cardio-Thoracic Department, School of Medicine, University Hospital of Verona, Verona, Italy.
| | - Federico Cecchini
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium.,Electrophysiology Unit, ZNA Middelheim, Antwerp, Belgium
| | - Erwin Stroker
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Gaetano Paparella
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Saverio Iacopino
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Yves De Greef
- Electrophysiology Unit, ZNA Middelheim, Antwerp, Belgium
| | - Luca Tomasi
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Cardio-Thoracic Department, School of Medicine, University Hospital of Verona, Verona, Italy
| | - Bruna Bolzan
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Cardio-Thoracic Department, School of Medicine, University Hospital of Verona, Verona, Italy
| | - Gezim Bala
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Anais Gauthey
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Flavio Luciano Ribichini
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Cardio-Thoracic Department, School of Medicine, University Hospital of Verona, Verona, Italy
| | - Carlo de Asmundis
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
2
|
Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation—Invasive Insights of TTI-Dependent Cryoenergy Titration. J Cardiovasc Dev Dis 2022; 9:jcdd9090284. [PMID: 36135429 PMCID: PMC9505807 DOI: 10.3390/jcdd9090284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 08/02/2022] [Accepted: 08/03/2022] [Indexed: 12/02/2022] Open
Abstract
Introduction: The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. TTI-based titration of cryoenergy allows individualized freeze duration and has emerged as a favorable ablation strategy in PV cryoablation. In a recent study, we demonstrated that omission of a bonus freeze and reduction in freeze duration to a minimum of 2 min in the case of short TTI led to comparable arrhythmia recurrence rates. Whereas clinical outcome seems to be comparable to fixed freeze duration, evidence of long-term PV reconnection rates in patients undergoing TTI-based cryoballoon ablation is sparse. Aim of the study: To evaluate the procedural efficacy of a single 2-min freeze for PVI, we assessed PV conduction recovery after cryoballoon PVI with a TTI-guided titration of freeze duration compared to a fixed ablation protocol. Methods and Results: We included consecutive patients with atrial fibrillation (AF) recurrence undergoing a second ablation procedure after the initial cryoballoon procedure. The second AF ablation procedure was performed by the 3D-mapping system and radiofrequency ablation technique. A total of 219 patients (age: 66.2 ± 10.8 years, 53% female, paroxysmal AF: 53%) treated with the TTI-guided protocol (174 patients, 685 PV) or fixed protocol (45 patients, 179 PV) showed comparable total reconnection rates (TTI: 36.9% vs. fixed: 31.8%, p = 0.21). The PV reconnection rate was not statistically different for PVs treated with a 2-min freeze in case of short TTI, compared to longer freeze duration. Interestingly, the PV reconnection rate was lower in LIPVs treated with the fixed protocol (13% vs. 31%, p = 0.029). In the TTI group, 17 out of 127 patients (15%) had durable isolation of all PVs, whereas in 8 out of 40 patients (20%) in the fixed group, all PVs were still isolated (p = 0.31). Conclusions: overall reconnection rate was not different using a TTI-guided ablation protocol compared to a fixed ablation protocol, whereas the LIPV reconnection rate was significantly lower in patients treated with a fixed ablation protocol.
Collapse
|
3
|
Mugnai G, Cecchini F, Stroker E, Paparella G, Iacopino S, Sieira J, De Greef Y, Tomasi L, Bolzan B, Bala G, Overeinder I, Almorad A, Gauthey A, Sorgente A, Ribichini FL, de Asmundis C, Chierchia GB. Durability of pulmonary vein isolation following cryoballoon ablation: Lessons from a large series of repeat ablation procedures. IJC HEART & VASCULATURE 2022; 40:101040. [PMID: 35514875 PMCID: PMC9062446 DOI: 10.1016/j.ijcha.2022.101040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 04/21/2022] [Indexed: 12/01/2022]
Abstract
Introduction The second-generation cryoballoon (CB) has emerged in the last decade as an effective treatment for atrial fibrillation (AF). This study sought to analyze the rate of PV reconnection following CB ablation, evaluate the most frequent PV sites of conduction recovery and finally to assess procedural and biophysical indicators of reconnection in a large cohort of patients undergoing repeat ablation for recurrence of atrial arrhythmias. Methods and Results A total of 300 consecutive patients (189 males, 63%; mean age 63.0 ± 11.1 years) underwent a repeat ablation after 18.2 ± 10.8 months from the index CB ablation. All repeat ablations were performed using a 3-dimensional electro-anatomical mapping system. Among all 1178 PVs, 209 (17.7%) showed a late PV reconnection in 177 patients (1.18 per patient), at the time of repeat ablation procedure. Overall, persistent PV isolation could be documented in 969 of 1178 PVs (82.3%). In 123 of 300 patients (41%), persistent isolation could be demonstrated in all PVs, whereas PV reconnection could be documented in 177 patients (59%). In the multivariable analysis, nadir temperature (p = 0.03), time to PV isolation (p = 0.01) and failure to achieve − 40 °C within 60 s (p = 0.05) were independently associated with late PV reconnection. Conclusions The rate of late PV reconnection after CB ablation was low (1.18 PVs/patient). The most frequent sites of reconnections were the superior-anterior portions for the upper PVs and the inferior-posterior portions for the lower PVs. Faster time to isolation, colder nadir temperatures and achievement of − 40 °C within 60 s were associated with durable PV isolation.
Collapse
Affiliation(s)
- Giacomo Mugnai
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium.,Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, University Hospital of Verona, Verona, Italy
| | - Federico Cecchini
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium.,Electrophysiology Unit, ZNA Middelheim, Antwerp, Belgium
| | - Erwin Stroker
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Gaetano Paparella
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Saverio Iacopino
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Yves De Greef
- Electrophysiology Unit, ZNA Middelheim, Antwerp, Belgium
| | - Luca Tomasi
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, University Hospital of Verona, Verona, Italy
| | - Bruna Bolzan
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, University Hospital of Verona, Verona, Italy
| | - Gezim Bala
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Alexandre Almorad
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Anais Gauthey
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Flavio Luciano Ribichini
- Electrophysiology and Cardiac Pacing, Division of Cardiology, Department of Medicine, University Hospital of Verona, Verona, Italy
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
4
|
Boghossian SHC, Mourilhe-Rocha R. Reconnection of Pulmonary Veins After Ablation. A Challenge to be Overcome. Arq Bras Cardiol 2021; 117:106-107. [PMID: 34320078 PMCID: PMC8294737 DOI: 10.36660/abc.20210438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Affiliation(s)
- Silvia Helena Cardoso Boghossian
- Universidade do Estado do Rio de JaneiroRio de JaneiroRJBrasilUniversidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ – Brasil
- Americas Medical City-Hospital VitóriaHospital Samaritano-BarraRio de JaneiroRJBrasilAmericas Medical City-Hospital Vitória e Hospital Samaritano-Barra, Rio de Janeiro, RJ - Brasil
- Hospital Pró CardíacoRio de JaneiroRJBrasilHospital Pró Cardíaco, Rio de Janeiro, RJ - Brasil
| | - Ricardo Mourilhe-Rocha
- Universidade do Estado do Rio de JaneiroRio de JaneiroRJBrasilUniversidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ – Brasil
- Americas Medical City-Hospital VitóriaHospital Samaritano-BarraRio de JaneiroRJBrasilAmericas Medical City-Hospital Vitória e Hospital Samaritano-Barra, Rio de Janeiro, RJ - Brasil
- Hospital Pró CardíacoRio de JaneiroRJBrasilHospital Pró Cardíaco, Rio de Janeiro, RJ - Brasil
| |
Collapse
|