1
|
Kravchenko D, Hart C, Garbe S, Luetkens JA, Isaak A, Mesropyan N, Vergnat M, Leyens J, Attenberger U, Kuetting D. Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease. Sci Rep 2022; 12:9934. [PMID: 35705551 PMCID: PMC9200716 DOI: 10.1038/s41598-022-13404-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 05/24/2022] [Indexed: 11/10/2022] Open
Abstract
To explore the image quality and radiation dose of dual source high-pitch cardiac computed tomography with tailored contrast injection protocols for pediatric congenital heart disease patients (CHD). In total, 27 infants with CHD (median age 109 days [IQR 6-199]) were retrospectively analyzed regarding dose length product (DLP) and effective dose (ED) after undergoing cardiothoracic CT imaging. Scan parameters were adjusted on a dual source/detector CT (DSCT) to minimize radiation dose while maintaining adequate quality. Image acquisition was performed at 70% of the R-R interval. Dose reducing measures included prospective electrocardiogram gating, utilizing slow injection velocities and foregoing bolus tracking during contrast injection. Image quality was assessed for artefacts, vessel definition, and noise on a 5-point scale (1 non-diagnostic, 5 excellent). Series were scored on a 0-to-3-point scale regarding answered clinical questions (0 non-diagnostic, 3 all clinical questions could be answered). The median DLP was 5.2 mGy*cm (IQR 3.5-7.8) leading to a median ED of 0.20 mSv (IQR 0.14-0.30). On average the acquired images scored 13.3 ± 2.1 (SD) out of a maximum 15 points with an intraclass correlation coefficient (ICC) of 0.94. All acquired series were able to fully answer all clinical questions scoring maximum points (ICC 1.0). Dual source high pitch CT protocols combined with custom contrast agent injection protocols in pediatric patients with CHD delivered sufficiently high diagnostic imaging quality combined with low submilisievert radiation doses. Prospective high pitch imaging is a reliable method for depiction of cardiac anatomy even in very young pediatric CHD patients with elevated heart rates.
Collapse
Affiliation(s)
- Dmitrij Kravchenko
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany. .,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany.
| | - Christopher Hart
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Department for Pediatric Cardiology, Children's Hospital, University of Bonn, Bonn, Germany
| | - Stephan Garbe
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany
| | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany
| | - Mathieu Vergnat
- Department of Pediatric Cardiothoracic Surgery, Children's Hospital, University of Bonn, Bonn, Germany
| | - Judith Leyens
- Department of Neonatology and Pediatric Intensive Care, Children's Hospital, University of Bonn, Bonn, Germany
| | - Ulrike Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany
| |
Collapse
|
2
|
Faria D, Augusto JB. In Search for Optimal Image Quality in Pediatric Cardiac CT Angiogram. Arq Bras Cardiol 2021; 116:106-107. [PMID: 33566973 PMCID: PMC8159505 DOI: 10.36660/abc.20201279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Affiliation(s)
- Daniel Faria
- Serviço de Cardiologia, Hospital Prof. Doutor Fernando Fonseca, Amadora - Portugal
| | - João B Augusto
- Serviço de Cardiologia, Hospital Prof. Doutor Fernando Fonseca, Amadora - Portugal.,Institute of Cardiovascular Sciences, University College London, Londres - Reino Unido.,Advanced Cardiac Imaging Department, Barts Heart Centre, Londres - Reino Unido
| |
Collapse
|