1
|
Johnson MI, Paley CA, Wittkopf PG, Mulvey MR, Jones G. Characterising the Features of 381 Clinical Studies Evaluating Transcutaneous Electrical Nerve Stimulation (TENS) for Pain Relief: A Secondary Analysis of the Meta-TENS Study to Improve Future Research. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:medicina58060803. [PMID: 35744066 PMCID: PMC9230499 DOI: 10.3390/medicina58060803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/08/2022] [Accepted: 06/10/2022] [Indexed: 12/29/2022]
Abstract
Background and Objectives: Characterising the features of methodologies, clinical attributes and intervention protocols, of studies is valuable to advise directions for research and practice. This article reports the findings of a secondary analysis of the features from studies screened as part of a large systematic review of TENS (the meta-TENS study). Materials and Methods: A descriptive analysis was performed on information associated with methodology, sample populations and intervention protocols from 381 randomised controlled trials (24,532 participants) evaluating TENS delivered at a strong comfortable intensity at the painful site in adults with pain, irrespective of diagnosis. Results: Studies were conducted in 43 countries commonly using parallel group design (n = 334) and one comparator group (n = 231). Mean ± standard deviation (SD) study sample size (64.05 ± 58.29 participants) and TENS group size (27.67 ± 21.90 participants) were small, with only 13 of 381 studies having 100 participants or more in the TENS group. Most TENS interventions were ‘high frequency’ (>10 pps, n = 276) and using 100 Hz (109/353 reports that stated a pulse frequency value). Of 476 comparator groups, 54.2% were active treatments (i.e., analgesic medication(s), exercise, manual therapies and electrophysical agents). Of 202 placebo comparator groups, 155 used a TENS device that did not deliver currents. At least 216 of 383 study groups were able to access other treatments whilst receiving TENS. Only 136 out of 381 reports included a statement about adverse events. Conclusions: Clinical studies on TENS are dominated by small parallel group evaluations of high frequency TENS that are often contaminated by concurrent treatment(s). Study reports tended focus on physiological and clinical implications rather than the veracity of methodology and findings. Previously published criteria for designing and reporting TENS studies were neglected and this should be corrected in future research using insights gleaned from this analysis.
Collapse
Affiliation(s)
- Mark I. Johnson
- Centre for Pain Research, School of Health, Leeds Beckett University, Leeds LS1 3HE, UK; (C.A.P.); (P.G.W.); (G.J.)
- Correspondence: ; Tel.: +44-113-812-30-83
| | - Carole A. Paley
- Centre for Pain Research, School of Health, Leeds Beckett University, Leeds LS1 3HE, UK; (C.A.P.); (P.G.W.); (G.J.)
- Research & Development Department, Airedale NHS Foundation Trust, Steeton, Keighley BD20 6TD, UK
| | - Priscilla G. Wittkopf
- Centre for Pain Research, School of Health, Leeds Beckett University, Leeds LS1 3HE, UK; (C.A.P.); (P.G.W.); (G.J.)
| | - Matthew R. Mulvey
- Academic Unit of Primary and Palliative Care, Leeds Institute of Health Sciences, University of Leeds, Leeds LS2 9NL, UK;
| | - Gareth Jones
- Centre for Pain Research, School of Health, Leeds Beckett University, Leeds LS1 3HE, UK; (C.A.P.); (P.G.W.); (G.J.)
| |
Collapse
|
2
|
Wong R, Major P, Sagar S. Phase 2 Study of Acupuncture-Like Transcutaneous Nerve Stimulation for Chemotherapy-Induced Peripheral Neuropathy. Integr Cancer Ther 2016; 15:153-64. [PMID: 27130723 DOI: 10.1177/1534735415627926] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 12/07/2015] [Indexed: 02/04/2023] Open
Abstract
A prospective phase 2 study was conducted to evaluate the clinical utility of acupuncture-like transcutaneous nerve stimulation (ALTENS) for the treatment of chemotherapy-induced peripheral neuropathy (CIPN). Eligible cancer patients had a < 2 ECOG performance score, received neurotoxic chemotherapy, and developed CIPN symptoms for > two months. Randomization was used to eliminate bias in patient selection for ALTENS and was not to compare the effectiveness between the two treatments.ALTENS treatments were delivered using Codetron units. Bilateral acupuncture points included LI4 and LIV3, plus LI11 or ST36 were stimulated. Acupuncture treatments were administered to CV6, SP6, ST6, LI11, Bafeng, Baxie and selective Jing points bilaterally. Twelve treatments were delivered twice weekly over 6 to 8 weeks. The Modified Total Neuropathy Score (mTNS), Numbness Score, and Edmonton Symptom Assessment Score (ESAS) were assessed at baseline, treatment completion, plus at 3 and 6 months follow-up. The primary study endpoint was mTNS score at 6 months. We planned to recruit 23 patients into each group. After 30 patients were recruited, 2 were lost to follow-up at 3 months in the ALTENS group and 3 in the acupuncture group. The research team decided to recruit all remaining consecutive patients only to the ALTENS group to ensure an adequate evaluation of ALTENS, the primary object of evaluation. There were 27 patients in the ALTENS group, with an average symptom duration of 10 months after chemotherapy. Twenty four and 23 patients completed the 3 and 6 month follow-up respectively. The median mTNS scores were 7.1, 4.0, 3.6 and 3.1 at baseline, treatment completion, 3 and 6 months follow-up, respectively. One-way ANOVA analysis showed a significant improvement in mTNS scores (p<0.001) at 6 months. Numbness scores were also significantly improved at 6 months. ESAS pain scores and perception of well-being scores analyses were inconclusive. There were no significant reported side effects of ALTENS. There were only 13 patients in the acupuncture group and the number was insufficient for either an independent or a comparative analysis. The results of this study suggests that ALTENS significantly reduces the mTNS scores and numbness in patients suffering from CIPN symptoms.
Collapse
Affiliation(s)
- Raimond Wong
- McMaster University-Juravinski Cancer Centre, Hamilton, ON, Canada
| | - Pierre Major
- McMaster University-Juravinski Cancer Centre, Hamilton, ON, Canada
| | - Stephen Sagar
- McMaster University-Juravinski Cancer Centre, Hamilton, ON, Canada
| |
Collapse
|
3
|
Novel Noxipoint Therapy versus Conventional Physical Therapy for Chronic Neck and Shoulder Pain: Multicentre Randomised Controlled Trials. Sci Rep 2015; 5:16342. [PMID: 26552835 PMCID: PMC4639784 DOI: 10.1038/srep16342] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 10/14/2015] [Indexed: 01/18/2023] Open
Abstract
As chronic pain affects 115 million people and costs $600B annually in the US alone, effective noninvasive nonpharmacological remedies are desirable. The purpose of this study was to determine the efficacy and the generalisability of Noxipoint therapy (NT), a novel electrotherapy characterised by site-specific stimulation, intensity-and-submodality-specific settings and a immobilization period, for chronic neck and shoulder pain. Ninety-seven heavily pretreated severe chronic neck/shoulder pain patients were recruited; 34 and 44 patients were randomly allocated to different treatment arms in two patient-and-assessor-blinded, randomised controlled studies. The participants received NT or conventional physical therapy including transcutaneous electrical nerve stimulation (PT-TENS) for three to six 90-minute sessions. In Study One, NT improved chronic pain (−89.6%, Brief Pain Inventory, p < 0.0001, 95% confidence interval), function (+77.4%, range of motion) and quality of life (+88.1%) at follow-up (from 4 weeks to 5 months), whereas PT-TENS resulted in no significant changes in these parameters. Study Two demonstrated similar advantages of NT over PT-TENS and the generalisability of NT. NT-like treatments in a randomised rat study showed a similar reduction in chronic hypersensitivity (−81%, p < 0.01) compared with sham treatments. NT substantially reduces chronic neck and shoulder pain, restores function, and improves quality of life in a sustained manner.
Collapse
|
4
|
[Acupuncture in fibromyalgia: a randomized, controlled study addressing the immediate pain response]. REVISTA BRASILEIRA DE REUMATOLOGIA 2014; 54:431-6. [PMID: 25458024 DOI: 10.1016/j.rbr.2014.06.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2013] [Revised: 04/30/2014] [Accepted: 06/08/2014] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To evaluate the efficacy of acupuncture in the treatment of fibromyalgia, considering the immediate response of the visual analogue pain scale (VAS) as its primary outcome. METHODS Randomized, controlled, double-blind study including 36 patients with fibromyalgia (ACR 1990) selected from the outpatient rheumatology clinic, Santa Casa de Misericórdia, Ponta Grossa, PR. Twenty-one patients underwent an acupuncture session, under the principles of the traditional Chinese medicine, and 15 patients underwent a placebo procedure (sham acupuncture). For pain assessment, the subjects completed a Visual Analogue Scale (VAS) before and immediately after the proposed procedure. The mean change in VAS was compared among groups. RESULTS The variation between the final and initial VAS values was -4.36±3.23 (P=0.0001) in the treatment group and -1.70±1.55 in the control group (P=0.06). The difference in terms of amplitude of variation of VAS (initial - final VAS) among groups favored the actual procedure (P=0.005). The effect size (ES) for the treatment group was d=1.7, which is considered a large effect. Although small, the statistical power of the sample for these results was very relevant (94.8%). CONCLUSION Acupuncture has proven effective in the immediate pain reduction in patients with fibromyalgia, with a quite significant effect size.
Collapse
|
5
|
Nnoaham KE, Kumbang J. WITHDRAWN: Transcutaneous electrical nerve stimulation (TENS) for chronic pain. Cochrane Database Syst Rev 2014:CD003222. [PMID: 25010718 DOI: 10.1002/14651858.cd003222.pub3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Kelechi E Nnoaham
- Public Health Medicine, University of Oxford, Rosemary Rue Building, Old Road Campus, Headington, Oxford, Oxfordshire, UK, OX3 7LF
| | | |
Collapse
|
6
|
Johnson MI. Acupuncture-like transcutaneous electrical nerve stimulation (AL-TENS) in the management of pain. PHYSICAL THERAPY REVIEWS 2013. [DOI: 10.1179/ptr.1998.3.2.73] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
7
|
|
8
|
Claydon LS, Chesterton LS. Does transcutaneous electrical nerve stimulation (TENS) produce 'dose-responses'? A review of systematic reviews on chronic pain. PHYSICAL THERAPY REVIEWS 2013. [DOI: 10.1179/174328808x373998] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
9
|
Rutjes AWS, Nüesch E, Sterchi R, Kalichman L, Hendriks E, Osiri M, Brosseau L, Reichenbach S, Jüni P. Transcutaneous electrostimulation for osteoarthritis of the knee. Cochrane Database Syst Rev 2009; 2009:CD002823. [PMID: 19821296 PMCID: PMC7120411 DOI: 10.1002/14651858.cd002823.pub2] [Citation(s) in RCA: 121] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Transcutaneous electrical nerve stimulation (TENS), interferential current stimulation and pulsed electrostimulation are used widely to control both acute and chronic pain arising from several conditions, but some policy makers regard efficacy evidence as insufficient. OBJECTIVES To compare transcutaneous electrostimulation with sham or no specific intervention in terms of effects on pain and withdrawals due to adverse events in patients with knee osteoarthritis. SEARCH STRATEGY We updated the search in CENTRAL, MEDLINE, EMBASE, CINAHL and PEDro up to 5 August 2008, checked conference proceedings and reference lists, and contacted authors. SELECTION CRITERIA Randomised or quasi-randomised controlled trials that compared transcutaneously applied electrostimulation with a sham intervention or no intervention in patients with osteoarthritis of the knee. DATA COLLECTION AND ANALYSIS We extracted data using standardised forms and contacted investigators to obtain missing outcome information. Main outcomes were pain and withdrawals or dropouts due to adverse events. We calculated standardised mean differences (SMDs) for pain and relative risks for safety outcomes and used inverse-variance random-effects meta-analysis. The analysis of pain was based on predicted estimates from meta-regression using the standard error as explanatory variable. MAIN RESULTS In this update we identified 14 additional trials resulting in the inclusion of 18 small trials in 813 patients. Eleven trials used TENS, four interferential current stimulation, one both TENS and interferential current stimulation, and two pulsed electrostimulation. The methodological quality and the quality of reporting was poor and a high degree of heterogeneity among the trials (I(2) = 80%) was revealed. The funnel plot for pain was asymmetrical (P < 0.001). The predicted SMD of pain intensity in trials as large as the largest trial was -0.07 (95% CI -0.46 to 0.32), corresponding to a difference in pain scores between electrostimulation and control of 0.2 cm on a 10 cm visual analogue scale. There was little evidence that SMDs differed on the type of electrostimulation (P = 0.94). The relative risk of being withdrawn or dropping out due to adverse events was 0.97 (95% CI 0.2 to 6.0). AUTHORS' CONCLUSIONS In this update, we could not confirm that transcutaneous electrostimulation is effective for pain relief. The current systematic review is inconclusive, hampered by the inclusion of only small trials of questionable quality. Appropriately designed trials of adequate power are warranted.
Collapse
Affiliation(s)
- Anne WS Rutjes
- University of BernDivision of Clinical Epidemiology and Biostatistics, Institute of Social and Preventive MedicineFinkenhubelweg 11BernSwitzerland3012
| | - Eveline Nüesch
- University of BernDivision of Clinical Epidemiology and Biostatistics, Institute of Social and Preventive MedicineFinkenhubelweg 11BernSwitzerland3012
| | - Rebekka Sterchi
- University of BernDivision of Clinical Epidemiology and Biostatistics, Institute of Social and Preventive MedicineFinkenhubelweg 11BernSwitzerland3012
| | - Leonid Kalichman
- Ben‐Gurion University of the NegevDepartment of Physical Therapy, Recanati School for Community Health Professions, Faculty of Health SciencesBeer ShevaIsrael84105
| | - Erik Hendriks
- Maastricht UniversityEpidemiology DepartmentP.O. Box 616MaastrichtNetherlandsNL‐6200 MD
| | - Manathip Osiri
- Faculty of MedicineDepartment of MedicineChulalongkorn University1873 Rama IV Road, PathumwanBangkokThailand10330
| | - Lucie Brosseau
- University of OttawaSchool of Rehabilitation Sciences, Faculty of Health Sciences451 Smyth RoadOttawaOntarioCanadaK1H 8M5
| | - Stephan Reichenbach
- University HospitalDepartment for Rheumatology, Clinical Immunology, and AllergologyInselspitalBernSwitzerland
| | - Peter Jüni
- University of BernDivision of Clinical Epidemiology and Biostatistics, Institute of Social and Preventive MedicineFinkenhubelweg 11BernSwitzerland3012
| | | |
Collapse
|
10
|
Johnson MI, Tabasam G. A double blind placebo controlled investigation into the analgesic effects of inferential currents (IFC) and transcutaneous electrical nerve stimulation (TENS) on cold-induced pain in healthy subjects. Physiother Theory Pract 2009. [DOI: 10.1080/095939899307630] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
11
|
Abstract
BACKGROUND Transcutaneous electrical nerve stimulation (TENS) is a popular pain treatment modality but its effectiveness in chronic pain management is unknown. This review is an update of the original Cochrane review published in Issue 3, 2001. OBJECTIVES To evaluate the effectiveness of TENS in chronic pain. SEARCH STRATEGY The Cochrane Library, EMBASE, MEDLINE and CINAHL were searched. Reference lists from retrieved reports and reviews were examined. Date of the most recent search: April 2008. SELECTION CRITERIA RCTs were eligible if they compared active TENS versus sham TENS controls; active TENS versus 'no treatment' controls; or active TENS versus active TENS controls (e.g. High Frequency TENS (HFTENS) versus Low Frequency TENS (LFTENS)). Studies of chronic pain for three months or more which included subjective outcome measures for pain intensity or relief were eligible for evaluation. No restrictions were made to language or sample size. Abstracts, letters, or unpublished studies, and studies of TENS in angina, headache, migraine, dysmenorrhoea and cancer-related pain were excluded. DATA COLLECTION AND ANALYSIS Data were extracted and summarised on the following items: patients and details of pain condition, treatments, study duration, design, methods, subjective pain outcome measures, methodological quality, results for pain outcome measures and adverse effects, and conclusions by authors of the studies. Extracted data and methodological quality of studies were confirmed by the review authors. MAIN RESULTS Of 124 studies identified from the searches, 99 did not fulfil pre-defined entry criteria. Twenty-five RCTs involving 1281 participants were evaluated. Included studies varied in design, analgesic outcomes, chronic pain conditions, TENS treatments and methodological quality. The reporting of methods and results for analgesic outcomes were inconsistent across studies and generally poor. Meta-analysis was not possible. Overall in 13 of 22 inactive control studies, there was a positive analgesic outcome in favour of active TENS treatments. For multiple dose treatment comparison studies, eight of fifteen were considered to be in favour of the active TENS treatments. Seven of the nine active controlled studies found no difference in analgesic efficacy between High Frequency (HF) TENS and Low Frequency (LF) TENS. AUTHORS' CONCLUSIONS Since the last version of this review, new relevant studies have not provided additional information to change the conclusions. Published literature on the subject lacks the methodological rigour or robust reporting needed to make confident assessments of the role of TENS in chronic pain management. Large multi-centre RCTs of TENS in chronic pain are still needed.
Collapse
Affiliation(s)
- Kelechi E Nnoaham
- Public Health Medicine, University of Oxford, Rosemary Rue Building, Old Road Campus, Headington, Oxford, Oxfordshire, UK, OX3 7LF.
| | | |
Collapse
|
12
|
Gadsby JG, Flowerdew MW. WITHDRAWN: Transcutaneous electrical nerve stimulation and acupuncture-like transcutaneous electrical nerve stimulation for chronic low back pain. Cochrane Database Syst Rev 2007; 2006:CD000210. [PMID: 17636620 PMCID: PMC10812864 DOI: 10.1002/14651858.cd000210.pub2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND In view of the claims and counter-claims of the effectiveness of transcutaneous electrical nerve stimulation, it would seem appropriate to systematically review the literature. OBJECTIVES To determine the effectiveness of transcutaneous electrical nerve stimulation in reducing pain and improving range of movement in patients with chronic low back pain. SEARCH STRATEGY Electronic searches of EMBASE, MEDLINE, CISCOM, AMED for all studies of TENS in the English language, identifying those treating chronic low back pain and hand searching their references. SELECTION CRITERIA The inclusion criterion for studies included in this review, 6 of 68 identified, was comparisons of TENS/ALTENS versus placebo in patients with chronic low back pain. DATA COLLECTION AND ANALYSIS Outcome data on pain reduction, range of movement, functional status and work was extracted by two independent reviewers together with trial design qualities to construct a Quality Index. MAIN RESULTS The ratio of odds of improvement in pain for each comparison was calculated: TENS vs. placebo at 1.62 (95% CI 0.90, 2.68); ALTENS vs. placebo at 7.22 (95% CI 2.60, 20.01) and TENS/ALTENS vs. placebo at 2.11 (95% CI 1.32, 3.38) times that of placebo. An improvement in pain reduction was seen in 45.80% (CI 37.00%, 55.00%) of TENS; 86.70% (CI 80.00%, 93.00%) of ALTENS; 54.00% (CI 46.20%, 61.80%) of TENS/ ALTENS and 36.40% (95%CI 28.40%, 44.40%) of placebo subjects. The odds of improvement in range of movement on ALTENS vs. placebo was 6.61 times (95% CI 2.36, 18.55) that of placebo. AUTHORS' CONCLUSIONS Transcutaneous electrical nerve stimulation appears to reduce pain and improve the range of movement in chronic low back pain subjects. A definitive randomised controlled study of ALTENS, TENS, placebo/no treatment controls, of sufficient power, is needed to confirm these findings.
Collapse
Affiliation(s)
- J G Gadsby
- De Montfort University, 47 Milton Crescent, Leicester, Leicestershire, UK, LE4 OPA.
| | | |
Collapse
|
13
|
Johnson M, Martinson M. Efficacy of electrical nerve stimulation for chronic musculoskeletal pain: a meta-analysis of randomized controlled trials. Pain 2007; 130:157-65. [PMID: 17383095 DOI: 10.1016/j.pain.2007.02.007] [Citation(s) in RCA: 147] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2006] [Revised: 02/13/2007] [Accepted: 02/13/2007] [Indexed: 11/24/2022]
Abstract
Previous studies and meta-analyses of the efficacy of electrical nerve stimulation (ENS) for the treatment of chronic pain of multiple etiologies have produced mixed results. The objective of the present study was to determine whether ENS is an effective treatment for chronic musculoskeletal pain by using statistical techniques that permit accumulation of a sample size with adequate power. Randomized, controlled trials published between January 1976 and November 2006 were obtained from the National Libraries of Medicine, EMBASE, and the Cochrane Library. Prospective, placebo-controlled studies using any modality of ENS to treat chronic musculoskeletal pain in any anatomical location were included. The main outcome measure was pain at rest. The use of statistical methods to enhance data extraction and a random-effects meta-analysis to accommodate heterogeneity of ENS therapies permitted an adequate number of well designed trials of ENS to be included in the meta-analysis. A total of 38 studies in 29 papers, which included 335 placebo, 474 ENS, and 418 cross-over (both placebo and at least one ENS treatment) patients, met the selection criteria. The overall results showed a significant decrease in pain with ENS therapy using a random-effects model (p<0.0005). These results indicate that ENS is an effective treatment modality for chronic musculoskeletal pain and that previous, equivocal results may have been due to underpowered studies.
Collapse
Affiliation(s)
- Michael Johnson
- Philosopher's River Consultancy, Willow Creek, MT 59760, USA
| | | |
Collapse
|
14
|
Abstract
OBJECTIVE To evaluate the evidence for the effectiveness of acupuncture in peripheral joint osteoarthritis (OA). METHODS Systematic searches were conducted on Medline, Embase, AMED, Cochrane Library, CINAHL, British Nursing Index, PsychINFO and CAMPAIN until July 2005. Hand-searches included conference proceedings and our own files. There were no restrictions regarding the language of publication. All randomized controlled trials (RCTs) of acupuncture for patients with peripheral joint OA were considered for inclusion. Trials assessing needle acupuncture with or without electrical stimulation were considered if sham- or placebo-controlled or controlled against a comparator intervention. Trials testing other forms of acupuncture were excluded. Methodological quality was assessed and, where possible, meta-analyses were performed. RESULTS Thirty-one possibly relevant studies were identified and 18 RCTs were included. Ten trials tested manual acupuncture and eight trials tested electro-acupuncture. Overall, ten studies demonstrated greater pain reduction in acupuncture groups compared with controls. The meta-analysis of homogeneous data showed a significant effect of manual acupuncture compared with sham acupuncture (standardized mean difference 0.24, 95% confidence interval 0.01-0.47, P = 0.04, n = 329), which is supported by data for knee OA. The extent of heterogeneity in trials of electro-acupuncture prevented a meaningful meta-analysis. CONCLUSIONS Sham-controlled RCTs suggest specific effects of acupuncture for pain control in patients with peripheral joint OA. Considering its favourable safety profile acupuncture seems an option worthy of consideration particularly for knee OA. Further studies are required particularly for manual or electro-acupuncture in hip OA.
Collapse
Affiliation(s)
- Y D Kwon
- Complementary Medicine, Peninsula Medical School, Universities of Exeter and Plymouth, 25 Victoria Park Road, Exeter EX2 4NT, UK
| | | | | |
Collapse
|
15
|
Sluka KA, Vance CGT, Lisi TL. High-frequency, but not low-frequency, transcutaneous electrical nerve stimulation reduces aspartate and glutamate release in the spinal cord dorsal horn. J Neurochem 2005; 95:1794-801. [PMID: 16236028 DOI: 10.1111/j.1471-4159.2005.03511.x] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a commonly utilized non-pharmacological treatment for pain. Studies show that low- and high-frequency TENS utilize opioid, serotonin and/or muscarinic receptors in the spinal cord to reduce hyperalgesia induced by joint inflammation in rats. As there is an increase in glutamate and aspartate levels in the spinal cord after joint inflammation, and opioids reduce glutamate and aspartate release, we hypothesized that TENS reduces release of glutamate and aspartate in animals with joint inflammation by activation of opioid receptors. Using microdialysis and HPLC with fluorescence detection, we examined the release pattern of glutamate and aspartate in the dorsal horn in response to either low-frequency (4 Hz) or high-frequency (100 Hz) TENS. We examined the effects of TENS on glutamate and aspartate release in animals with and without joint inflammation. High-frequency, but not low-frequency, TENS significantly reduced spinal glutamate and aspartate in animals with joint inflammation compared with levels in those without joint inflammation. The reduced release of glutamate and aspartate by high-frequency TENS was prevented by spinal blockade of delta-opioid receptors with naltrindole. Thus, we conclude that high-frequency TENS activates delta-opioid receptors consequently reducing the increased release of glutamate and aspartate in the spinal cord.
Collapse
Affiliation(s)
- K A Sluka
- Physical Therapy and Rehabilitation Science Graduate Program, University of Iowa, Iowa City, Iowa 52242, USA.
| | | | | |
Collapse
|
16
|
Cheing GLY, Hui-Chan CWY. Would the addition of TENS to exercise training produce better physical performance outcomes in people with knee osteoarthritis than either intervention alone? Clin Rehabil 2004; 18:487-97. [PMID: 15293483 DOI: 10.1191/0269215504cr760oa] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE To examine if the addition of transcutaneous electrical nerve stimulation (TENS) to exercise training would produce better physical outcomes than TENS or exercise alone in people with knee osteoarthritis. DESIGN Sixty-two subjects were randomly allocated to four groups. INTERVENTIONS Patients received either (1) TENS, (2) placebo stimulation, (3) exercise training, or (4) TENS and exercise training five days a week for four weeks. MAIN OUTCOME MEASURES The isometric peak torque, spatiotemporal gait parameters and range of knee movement were assessed in treatment session1, session10 and session20 and the four-week follow-up. RESULTS By session20, the TENS and exercise group demonstrated an average of 26.6% cumulative gain in the knee extensor peak torque for the different knee positions (all p < 0.05). Although the between-group difference was short of being statistically significant, the gain found in the TENS and exercise group was greater than that found in the other three groups. The TENS and exercise group also tended to show greater cumulative increase in stride length (12.6%, p = 0.006), walking cadence (9.3%, p = 0.098) and gait velocity (22.4%, p = 0.034) than the other groups. By session20, it was the only group that produced a significant increase in the range of knee motion during walking (12.0%, p = 0.000). The TENS group and the exercise group both demonstrated some improvements in the above physical outcomes, but negligible change was found in the group receiving placebo stimulation (all p > 0.05). CONCLUSION No significant difference was found among the four treatment protocols, but the addition of TENS to exercise training tended to produce the best overall improvement in physical outcomes in people with knee osteoarthritis.
Collapse
Affiliation(s)
- Gladys L Y Cheing
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | | |
Collapse
|
17
|
Cheing GLY, Hui-Chan CWY, Chan KM. Does four weeks of TENS and/or isometric exercise produce cumulative reduction of osteoarthritic knee pain? Clin Rehabil 2002; 16:749-60. [PMID: 12428824 DOI: 10.1191/0269215502cr549oa] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE To evaluate the cumulative effect of repeated transcutaneous electrical nerve stimulation (TENS) on chronic osteoarthritic (OA) knee pain over a four-week treatment period, comparing it to that of placebo stimulation and exercise training given alone or in combination with TENS. DESIGN Sixty-two patients, aged 50-75, were stratified according to age, gender and body mass ratio before being randomly assigned to four groups. INTERVENTIONS Patients received either (1) 60 minutes of TENS, (2) 60 minutes of placebo stimulation, (3) isometric exercise training, or (4) TENS and exercise (TENS & Ex) five days a week for four weeks. MAIN OUTCOME MEASURES Visual analogue scale (VAS) was used to measure knee pain intensity before and after each treatment session over a four-week period, and at the four-week follow-up session. RESULTS Repeated measures ANOVA showed a significant cumulative reduction in the VAS scores across the four treatment sessions (session 1, 10, 20 and the follow-up) in the TENS group (45.9% by session 20, p < 0.001) and the placebo group (43.3% by session 20, p = 0.034). However, linear regression of the daily recordings of the VAS indicated that the slope in the TENS group (slope = -2.415, r = 0.943) was similar to the exercise group (slope = -2.625, r = 0.935), which were steeper than the other two groups. Note that the reduction of OA knee pain was maintained in the TENS group and the TENS & Ex group at the four-week follow-up session, but not in the other two groups. CONCLUSIONS The four treatment protocols did not show significant between-group difference over the study period. It was interesting to note that isometric exercise training of the quadriceps alone also reduced knee pain towards the end of the treatment period.
Collapse
Affiliation(s)
- Gladys L Y Cheing
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon
| | | | | |
Collapse
|
18
|
Johnson MI, Tabasam G. A single-blind placebo-controlled investigation into the analgesic effects of interferential currents on experimentally induced ischaemic pain in healthy subjects. Clin Physiol Funct Imaging 2002; 22:187-96. [PMID: 12076344 DOI: 10.1046/j.1475-097x.2002.00416.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The aim of this single-blind placebo-controlled study was to examine the analgesic effects of interferential currents (IFC) on experimentally induced ischaemic pain. Ischaemic pain was induced using the submaximal effort tourniquet technique (SETT) and pain intensity was recorded using a visual analogue scale at 1-min intervals was used as the primary outcome measure. Following baseline recordings 30 healthy volunteers received either active IFC, sham IFC, or no treatment (10 subjects per group). Data were analysed by calculating the mean change in pain intensity at each 1-min interval by subtracting data during treatment from the baseline data. IFC was administered throughout the duration of the ischaemic pain test via four electrodes (quadripolar application) on the forearm. Active IFC delivered electrical currents at a 'strong but comfortable' intensity. A 'dummy' stimulator that delivered no current was used as sham IFC. Subjects in the no treatment control group were informed that the IFC device was not switched on. There were significant effects for Groups (P=0.04) which were attributed to a significant reduction in pain intensity for the IFC group when compared with sham and no-treatment control (P< or =0.05). There were no significant effects for Time (P=0.69) or Group-Time interaction (P=0.45). In conclusion, IFC produced significantly greater analgesia than sham and no-treatment control groups under the present experimental conditions.
Collapse
Affiliation(s)
- Mark I Johnson
- Principal Lecturer in Human Physiology, School of Health Sciences, Faculty of Health and Environment, Leeds Metropolitan University, Leeds, UK.
| | | |
Collapse
|
19
|
Carroll D, Moore RA, McQuay HJ, Fairman F, Tramèr M, Leijon G. Transcutaneous electrical nerve stimulation (TENS) for chronic pain. Cochrane Database Syst Rev 2001:CD003222. [PMID: 11687055 DOI: 10.1002/14651858.cd003222] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Transcutaneous electrical nerve stimulation (TENS) is used in a variety of different clinical settings to treat a range of different acute and chronic pain conditions and has become popular with both patients and health professionals. OBJECTIVES To evaluate the effectiveness of TENS in chronic pain. SEARCH STRATEGY The Cochrane Library, Embase, Medline, CINAHL and The Oxford Pain Database were searched. Reference lists from retrieved reports and reviews were examined. Date of the most recent search: March 1999. SELECTION CRITERIA RCTs were eligible if they included the following treatment comparisons: active TENS versus sham TENS controls active TENS versus no treatment controls active TENS versus active TENS controls (for instance High Frequency TENS vs Low Frequency TENS) Studies of patients suffering chronic pain for three months or more which included subjective outcome measures for pain intensity, or pain relief were eligible for evaluation in this review. No restrictions were made to language or sample size. Data from abstracts, letters, or unpublished studies, and studies of TENS in angina, headache and migraine, and dysmenorrhoea were not included. DATA COLLECTION AND ANALYSIS Data were extracted and summarised on the following items: patients and details of pain condition, study treatments, study duration, design, methods, subjective pain outcome measures, methodological quality, results for pain outcome measures and adverse effects, and the conclusions made by the authors of the original studies. Extracted data and methodological quality of each report was confirmed by at least three of the reviewers. MAIN RESULTS Of 107 reports identified from the searches, 88 were excluded as they did not fulfil the pre-defined entry criteria. Nineteen RCTs (from 18 reports) were evaluated. The included trials varied in terms of design, analgesic outcomes, chronic pain conditions, TENS treatments and overall methodological quality. Studies included single and multiple dose treatment comparisons of TENS. The studies were small. The reporting of the methods used and results for the analgesic outcomes were generally poor. TENS treatments and controls were often poorly defined. Few studies evaluated the long-term analgesic effectiveness of TENS and single dose evaluations of TENS are unhelpful in making clinical decisions of the long-term effectiveness of TENS in the management of chronic pain. Meta-analysis was not possible. Overall in 10 of 15 inactive control studies there was a positive analgesic outcome in favour of the active TENS treatments. For the multiple dose treatment comparison studies only three of seven were considered to be in favour of the active TENS treatments. For the active controlled studies, seven studies made direct comparisons between HFTENS and LFTENS. Five of seven studies could find no difference in terms of analgesic efficacy between HFTENS and LFTENS at any time point. REVIEWER'S CONCLUSIONS The results of this review are inconclusive; the published trials do not provide information on the stimulation parameters which are most likely to provide optimum pain relief, nor do they answer questions about long-term effectiveness. Large multi-centre randomised controlled trials of TENS in chronic pain are urgently needed.
Collapse
Affiliation(s)
- D Carroll
- IPC 814, Pfizer Ltd, Sandwich, Kent, UK, CT13 9NJ.
| | | | | | | | | | | |
Collapse
|
20
|
Gopalkrishnan P, Sluka KA. Effect of varying frequency, intensity, and pulse duration of transcutaneous electrical nerve stimulation on primary hyperalgesia in inflamed rats. Arch Phys Med Rehabil 2000; 81:984-90. [PMID: 10896017 DOI: 10.1053/apmr.2000.5576] [Citation(s) in RCA: 105] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES To examine the effect of varying frequency, intensity, and pulse duration of transcutaneous electrical nerve stimulation (TENS) on primary hyperalgesia (increased response to a noxious stimuli) to heat and mechanical stimuli induced by carrageenan paw inflammation in rats. DESIGN Inflammation was induced by injection of 3% carrageenan into the hindpaw. Two frequencies (high, 100 Hz; low, 4 Hz), 2 intensities (high, motor; low, sensory), and 2 pulse durations (100 microsec, 250 microsec) were applied for 20 minutes to the inflamed paw. The paw withdrawal latency (PWL) to radiant heat, threshold to mechanical stimuli, and spontaneous pain-related behaviors were measured before and 4 hours after induction of inflammation, after TENS, and at 8, 12, and 24 hours after inflammation. A 3-factor (frequency, intensity, pulse duration) repeated-measures (time) design was used to analyze the changes in PWL. Mechanical threshold and spontaneous pain-related behaviors were compared for frequency, intensity, and pulse duration with a Kruskal-Wallis analysis of variance. RESULTS For changes in PWL to heat, there was an effect for time (p = .0001) and frequency (p =.0001), but not for intensity (p = .45) or pulse duration (p = .21). For changes in mechanical threshold, there was also an effect for frequency (p = .007), but not for intensity (p = .055) or pulse duration (p = .058), after treatment with TENS. High-frequency TENS significantly reduced the primary hyperalgesia to heat and mechanical stimuli when compared with controls receiving no TENS or treatment with low-frequency TENS. High-frequency motor TENS also reduced spontaneous pain-related behaviors for 1 day after treatment. CONCLUSION High-frequency TENS reduces primary hyperalgesia to heat and mechanical stimuli for up to 1 day after treatment. In contrast, low-frequency TENS is ineffective in reducing primary hyperalgesia. Varying intensity or pulse duration had no effect on the degree of antihyperalgesia produced by high-frequency TENS.
Collapse
Affiliation(s)
- P Gopalkrishnan
- Physical Therapy Graduate Program, College of Medicine, University of Iowa, Iowa City 52242, USA
| | | |
Collapse
|
21
|
Gadsby JG, Flowerdew MW. Transcutaneous electrical nerve stimulation and acupuncture-like transcutaneous electrical nerve stimulation for chronic low back pain. Cochrane Database Syst Rev 2000:CD000210. [PMID: 10796326 DOI: 10.1002/14651858.cd000210] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Transcutaneous electrical nerve stimulation (TENS), originally based on the gate-control theory of pain, is widely used for the treatment of chronic low back pain. Despite its wide use and theoretical rationale, there appears at first glance little scientific evidence to support its use. This Cochrane review examines the available evidence on TENS for the treatment of chronic back pain through an exhaustive search of the literature. OBJECTIVES Transcutaneous electrical nerve stimulation (TENS) and acupuncture-like transcutaneous electrical nerve stimulation (ALTENS) for chronic low back pain management have experienced a tremendous growth over the past 25 years. The objective of this review was to assess the effects of TENS and ALTENS for reducing pain and improving function in patients with chronic back pain. SEARCH STRATEGY We searched MEDLINE up to November 1997, EMBASE from 1985 to September 1995, Amed and Ciscom to January 1995, reference lists of the retrieved articles, proceedings of conferences and contacted investigators in the field. SELECTION CRITERIA Randomised trials comparing TENS or ALTENS therapy to placebo in patients with chronic low back pain. DATA COLLECTION AND ANALYSIS Two reviewers independently assessed trial quality and extracted data on pain reduction, range of movement, functional and work status. MAIN RESULTS Six trials were included. The trials included 288 participants with an average age range of 45 to 50 years and approximately equal numbers of women and men. The overall odds ratio for improvement in pain for each comparison was: TENS/ALTENS versus placebo 2.11 (95% confidence interval 1.32 to 3. 38), ALTENS versus placebo 7.22 (95% confidence interval 2.60 to 20.01) and TENS versus placebo 1.52 (95% confidence interval 0.90 to 2.58). The odds ration for improvement in range of motion on ALTENS versus placebo was 6.61 (95% confidence interval 2.36 to 18.55). REVIEWER'S CONCLUSIONS There is evidence from the limited data available that TENS/ALTENS reduces pain and improves range of motion in chronic back pain patients, at least in the short term. A large trial of ALTENS and TENS is needed to confirm these findings.
Collapse
Affiliation(s)
- J G Gadsby
- 47 Milton Crescent, Leicester, Leicestershire, UK, LE4 OPA.
| | | |
Collapse
|
22
|
Wong AM, Su TY, Tang FT, Cheng PT, Liaw MY. Clinical trial of electrical acupuncture on hemiplegic stroke patients. Am J Phys Med Rehabil 1999; 78:117-22. [PMID: 10088585 DOI: 10.1097/00002060-199903000-00006] [Citation(s) in RCA: 89] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
To assess the efficacy of electrical acupuncture in the rehabilitation of patients with hemiplegia in stroke, we randomized 128 patients within 2 wk of stroke onset to receive either comprehensive rehabilitation plus electrical acupuncture (n = 59) or comprehensive rehabilitation only (n = 59). Electrical acupuncture was administered by electrical stimulation of acupuncture points through adhesive surface electrodes five times per week. Neurological status (Brunnstrom's stage) and the Chinese version of the Functional Independence Measure were assessed before treatment and at discharge. Patients treated with electrical acupuncture had a shorter duration of hospital stay for rehabilitation and better neurological and functional outcomes than the control group had, with a significant difference in scores for self-care and locomotion (P = 0.02). This result did not postulate the previous study that acupuncture therapy for stroke patients should depend on needle manual and "de qi" response. We suggest that electrical acupuncture through adhesive surface electrodes in conjunction with current optimal rehabilitation programs is a convenient and effective therapy for stroke patients.
Collapse
Affiliation(s)
- A M Wong
- Department of Physical Medicine & Rehabilitation, Chang Gung Memorial Hospital and Chang Gung University, Taipei, Taiwan
| | | | | | | | | |
Collapse
|
23
|
Vickers A, Rees R, Zollman C, Smith C, Ellis N. Acupuncture for migraine and headache in primary care: a protocol for a pragmatic, randomized trial. Complement Ther Med 1999; 7:3-18. [PMID: 10361566 DOI: 10.1016/s0965-2299(99)80053-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
UNLABELLED This paper presents the protocol for a randomized trial of acupuncture for migraine and headache. SUBJECTS Four hundred patients with migraine or headache will be recruited from GP practices. INCLUSION CRITERIA Eighteen to 65 years old, contractable by telephone, onset at least 1 year prior at age less than 50, two headaches per month in the previous 6 months, adequate data completion and headache severity during pre-randomization baseline. EXCLUSION CRITERIA Pregnancy or malignancy, cluster headache, serious pathological aetiology, cranial neuralgia, acupuncture treatment in the past year. DESIGN Following a 4-week baseline, patients will be allocated to acupuncture or control by minimized randomization. Up to 12 acupuncture treatments will be provided by advanced members of the Acupuncture Association of Chartered Physiotherapists. The type of acupuncture given will be recorded. STUDY MEASURES: Outcome will be assessed by headache diary, medication diary and SF36 at 3 months and 1 year. Resource use and days off sick will be assessed by quarterly questionnaire. Adverse events will be monitored by self-report. The primary outcome measure will be the change in mean daily headache score between baseline and the 1 year follow-up. An economic evaluation will also be undertaken.
Collapse
Affiliation(s)
- A Vickers
- Research Council for Complementary Medicine, London, UK.
| | | | | | | | | |
Collapse
|
24
|
Salansky N, Fedotchev A, Bondar A. Responses of the nervous system to low frequency stimulation and EEG rhythms: clinical implications. Neurosci Biobehav Rev 1998; 22:395-409. [PMID: 9579328 DOI: 10.1016/s0149-7634(97)00029-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The present paper reviews literature data on the role of the non-specific central nervous system response mechanisms on the therapeutic effects of relatively weak external stimulations used in clinical practice. The factors affecting the stimulation efficiency and increased sensitiveness of living things to extra-low-frequency periodic stimulations (in the range of from less than 1 Hz to tens of Hz) are discussed. Among the factors determining such effects, the non-specific response mechanisms of the nervous system, the resonance phenomena in different organism systems, and the interaction of external stimulation with endogenous rhythmic processes are analyzed. Most attention is given to endogenous rhythms of the electrical brain activity reflected in the EEG rhythms. A high resolution EEG processing approach that is used to reveal the intrinsic oscillators in the individual EEG spectrum is described. Synchronization of sensory stimulation parameters with the frequencies of intrinsic EEG oscillators is supposed to be an appropriate way to enhance the therapeutic effects of various sensory stimulation treatments. Specific methods for utilizing resonance therapy via sensory stimulation with intrinsic EEG frequencies, and for automatic modulation of stimulation parameters by endogenous organism rhythms are delineated; some preliminary results are described.
Collapse
Affiliation(s)
- N Salansky
- Selye-Toffler University, Toronto, Ont., Canada
| | | | | |
Collapse
|
25
|
Flowerdew M, Gadsby J. A review of the treatment of chronic low back pain with acupuncture-like transcutaneous electrical nerve stimulation and transcutaneous electrical nerve stimulation. Complement Ther Med 1997. [DOI: 10.1016/s0965-2299(97)80029-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
26
|
Salansky N, Fedotchev A. Endogenous opioid peptide level changes under electrostimulation and their assessment by the EEG. Int J Neurosci 1994; 78:193-205. [PMID: 7883456 DOI: 10.3109/00207459408986058] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Endogenous opioid peptide (EOP) system plays an important role in the interaction of human organism with different stress factors, providing stress-limiting and stress-protective functions. Different kinds of electrostimulation seem to produce anti-stress and pain relief effects due to EOP system activation. The presented paper reviews recent literature concerning EOP system activation under electrostimulation and its reflections in the EEG characteristics. The results and opportunities of high resolution EEG structure analysis utilization for EOP level control, as well as for stress-induced state assessment and correction via resonance activation of brain EEG oscillators by means of frequency-tuned external stimulation are presented.
Collapse
Affiliation(s)
- N Salansky
- Institute for Aerospace Studies, University of Toronto, Ontario, Canada
| | | |
Collapse
|