1
|
Comparing walking with knee-ankle-foot orthoses and a knee-powered exoskeleton after spinal cord injury: a randomized, crossover clinical trial. Sci Rep 2022; 12:19150. [PMID: 36351989 PMCID: PMC9646697 DOI: 10.1038/s41598-022-23556-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 11/02/2022] [Indexed: 11/11/2022] Open
Abstract
Recovering the ability to stand and walk independently can have numerous health benefits for people with spinal cord injury (SCI). Wearable exoskeletons are being considered as a promising alternative to conventional knee-ankle-foot orthoses (KAFOs) for gait training and assisting functional mobility. However, comparisons between these two types of devices in terms of gait biomechanics and energetics have been limited. Through a randomized, crossover clinical trial, this study compared the use of a knee-powered lower limb exoskeleton (the ABLE Exoskeleton) against passive orthoses, which are the current standard of care for verticalization and gait ambulation outside the clinical setting in people with SCI. Ten patients with SCI completed a 10-session gait training program with each device followed by user satisfaction questionnaires. Walking with the ABLE Exoskeleton improved gait kinematics compared to the KAFOs, providing a more physiological gait pattern with less compensatory movements (38% reduction of circumduction, 25% increase of step length, 29% improvement in weight shifting). However, participants did not exhibit significantly better results in walking performance for the standard clinical tests (Timed Up and Go, 10-m Walk Test, and 6-min Walk Test), nor significant reductions in energy consumption. These results suggest that providing powered assistance only on the knee joints is not enough to significantly reduce the energy consumption required by people with SCI to walk compared to passive orthoses. Active assistance on the hip or ankle joints seems necessary to achieve this outcome.
Collapse
|
2
|
Rodriguez Tapia G, Doumas I, Lejeune T, Previnaire JG. Wearable powered exoskeletons for gait training in tetraplegia: a systematic review on feasibility, safety and potential health benefits. Acta Neurol Belg 2022; 122:1149-1162. [DOI: 10.1007/s13760-022-02011-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/16/2022] [Indexed: 11/01/2022]
|
3
|
Rehabilitation Program for Gait Training Using UAN.GO, a Powered Exoskeleton: A Case Report. Neurol Int 2022; 14:536-546. [PMID: 35736624 PMCID: PMC9227123 DOI: 10.3390/neurolint14020043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/10/2022] [Accepted: 06/14/2022] [Indexed: 01/25/2023] Open
Abstract
Background: Spinal cord injury is characterized by the interruption of neural pathways of the spinal cord, with alteration of sensory, motor, and autonomic functions. Robotic-assisted gait training offers many possibilities, including the capability to reach a physiological gait pattern. Methods: A training protocol with UAN.GO®, an active lower limb exoskeleton, was developed. A participant having D10 complete SCI was recruited for this study. The training protocol was composed by 13 sessions, lasting 1.5 h each. The effectiveness of the protocol was evaluated through the mobility performance during the 6 MWT, the level of exertion perceived administrating Borg RPE at the end of each 6 MWT. Furthermore, time and effort required by the participant to earn a higher level of skills were considered. Results: A significant improvement was registered in the six MWT (t0 = 45.64 m t1 = 84.87 m). Data referring to the mean level of exertion remained stable. The patient successfully achieved a higher level of independence and functional mobility with the exoskeleton. Discussion: The findings from this preliminary study suggest that UAN.GO can be a valid tool for walking rehabilitation of spinal cord injury patients, allowing the achievement of greater mobility performances.
Collapse
|
4
|
Development of a 3D Relative Motion Method for Human-Robot Interaction Assessment. SENSORS 2022; 22:s22062411. [PMID: 35336593 PMCID: PMC8952123 DOI: 10.3390/s22062411] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 12/10/2022]
Abstract
Exoskeletons have been assessed by qualitative and quantitative features known as performance indicators. Within these, the ergonomic indicators have been isolated, creating a lack of methodologies to analyze and assess physical interfaces. In this sense, this work presents a three-dimensional relative motion assessment method. This method quantifies the difference of orientation between the user’s limb and the exoskeleton link, providing a deeper understanding of the Human–Robot interaction. To this end, the AGoRA exoskeleton was configured in a resistive mode and assessed using an optoelectronic system. The interaction quantified a difference of orientation considerably at a maximum value of 41.1 degrees along the sagittal plane. It extended the understanding of the Human–Robot Interaction throughout the three principal human planes. Furthermore, the proposed method establishes a performance indicator of the physical interfaces of an exoskeleton.
Collapse
|
5
|
Preliminary training volume and progression algorithm to tackle fragility fracture risk during exoskeleton-assisted overground walking in individuals with a chronic spinal cord injury. Spinal Cord Ser Cases 2022; 8:29. [PMID: 35260550 PMCID: PMC8904785 DOI: 10.1038/s41394-022-00498-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 02/17/2022] [Accepted: 02/20/2022] [Indexed: 11/08/2022] Open
|
6
|
Pinto-Fernandez D, Torricelli D, Sanchez-Villamanan MDC, Aller F, Mombaur K, Conti R, Vitiello N, Moreno JC, Pons JL. Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review. IEEE Trans Neural Syst Rehabil Eng 2021; 28:1573-1583. [PMID: 32634096 DOI: 10.1109/tnsre.2020.2989481] [Citation(s) in RCA: 54] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.
Collapse
|
7
|
Treviño LR, Roberge P, Auer ME, Morales A, Torres-Reveron A. Predictors of Functional Outcome in a Cohort of Hispanic Patients Using Exoskeleton Rehabilitation for Cerebrovascular Accidents and Traumatic Brain Injury. Front Neurorobot 2021; 15:682156. [PMID: 34177511 PMCID: PMC8222710 DOI: 10.3389/fnbot.2021.682156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/17/2021] [Indexed: 12/12/2022] Open
Abstract
Traumatic brain injury (TBI) and cerebrovascular accidents (CVA) are two of the leading causes of disability in the United States. Robotic exoskeletons (RE) have been approved for rehabilitation by the Federal Drug Administration (FDA) for use after a CVA, and recently received approval for use in patients with TBI. The aim of the study was to determine which factors predict the improvement in functional independence measure (FIM) score after using RE rehabilitation in a population of patients with CVA or TBI. We carried out a retrospective chart-review analysis of the use of the RE (Ekso® GT) in the rehabilitation of patients with TBI and CVA using data from a single, private rehabilitation hospital for patients admitted and discharged between 01/01/2017 and 04/30/2020. From the medical records, we collected presentation date, Glasgow Coma Scale score (GCS) on the date of injury, rehabilitation start date, age, diabetes status on presentation (Yes or No), injury category (TBI or CVA), and both admission and discharge FIM scores. Matching algorithms resulted in one TBI patient matched to three CVA patients resulting in a sample size of 36. The diabetic and non-diabetic populations showed significant differences between age and days from injury to the start of rehabilitation. A multivariate linear regression assessed predictors for discharge motor FIM and found admission motor FIM score and total RE steps to be statistically significant predictors. For each point scored higher on the admission motor FIM the discharge FIM was increased by 1.19 FIM points, and for each 1,000 steps taken in the RE, the discharge motor FIM increased by three points. The type of acquired brain injury (CVA or TBI) was not found to affect functional outcome. The presented results show that key clinic-biologic factors including diabetic status, together with start to rehabilitation play key roles in discharge FIM scores for patients using RE. Clinical Trial Registration: ClinicalTrials.gov, NCT04465019.
Collapse
Affiliation(s)
- Lisa R. Treviño
- DHR Health Institute for Research and Development, Edinburg, TX, United States
| | - Peter Roberge
- DHR Health Institute for Research and Development, Edinburg, TX, United States
| | - Michael E. Auer
- The DHR Health Rehabilitation Hospital, Edinburg, TX, United States
| | - Angela Morales
- The DHR Health Rehabilitation Hospital, Edinburg, TX, United States
| | | |
Collapse
|
8
|
Exoskeletal-assisted walking may improve seated balance in persons with chronic spinal cord injury: a pilot study. Spinal Cord Ser Cases 2021; 7:20. [PMID: 33712561 DOI: 10.1038/s41394-021-00384-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 01/05/2021] [Accepted: 02/10/2021] [Indexed: 11/09/2022] Open
Abstract
STUDY DESIGN Pre-post intervention. OBJECTIVE To explore the potential effect of exoskeletal-assisted walking (EAW) on seated balance for persons with chronic motor complete spinal cord injury (SCI). SETTING A SCI research center. METHODS Eight participants who were over 18 years of age with chronic SCI and used a wheelchair for mobility were enrolled. Seven able-bodied participants were used for normal seated balance comparative values. Participants with chronic SCI received supervised EAW training using a powered exoskeleton (ReWalkTM) for a median 30 sessions (range from 7 to 90 sessions). Before and after EAW training, seated balance testing outcomes were collected using computerized dynamic posturography, providing measurements of endpoint excursion (EPE), maximal excursion (MXE), and directional control (DCL). Modified functional reach test (MFRT) and the sub-scales of physical functioning and role limitations due to physical health from the Short Form (36) Health Survey (SF-36) were used to identify changes in functional activities. RESULTS After EAW training, seated balance significantly improved in total-direction EPE and MXE (P < 0.01 and P < 0.017 respectively). The results of MFRT and sub-scales of physical functioning and role limitations due to physical health improved after EAW training but were not statistically significant. CONCLUSIONS EAW training may have the potential to improve seated balance for persons with chronic motor complete SCI. Due to the limitations of the study, such as small sample size and lack of a control group, further studies are needed to clarify the effect of improving seated balance through EAW training.
Collapse
|
9
|
Tan K, Koyama S, Sakurai H, Teranishi T, Kanada Y, Tanabe S. Wearable robotic exoskeleton for gait reconstruction in patients with spinal cord injury: A literature review. J Orthop Translat 2021; 28:55-64. [PMID: 33717982 PMCID: PMC7930505 DOI: 10.1016/j.jot.2021.01.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/25/2020] [Accepted: 01/07/2021] [Indexed: 12/13/2022] Open
Abstract
Objectives Wearable robotic exoskeletons (WREs) have been globally developed to achieve gait reconstruction in patients with spinal cord injury (SCI). The present study aimed to enable evidence-based decision-making in selecting the optimal WRE according to residual motor function and to provide a new perspective on further development of appropriate WREs. Methods The current review was conducted by searching PubMed, Web of Science, and Google Scholar for relevant studies published from April 2015 to February 2020. Selected studies were analysed with a focus on the participants’ neurological level of SCI, amount of training (number of training sessions and duration of the total training period), gait speed and endurance achieved, and subgroup exploration of the number of persons for assistance and the walking aid used among patients with cervical level injury. Results A total of 28 articles (nine using Ekso, three using Indego, ten using ReWalk, one using REX, five using Wearable Power-Assist Locomotor) involving 228 patients were included in the analysis. Across all WREs, T6 was the most frequently reported level of SCI. The amount of training showed a wide distribution (number of training sessions: 2–230 sessions [30–120 min per session]; duration of the total training period: 1–24 weeks [1–5 times per week]). The mean gait speed was 0.31 m/s (standard deviation [SD] 0.14), and the mean distance on the 6-min walking test as a measure of endurance was 108.9 m (SD 46.7). The subgroup exploration aimed at patients with cervical level injury indicated that 59.2% of patients were able to ambulate with no physical assistance and several patients used a walker as a walking aid. Conclusion The number of cervical level injury increased, as compared to the number previously indicated by a prior similar review. Training procedure was largely different among studies. Further improvement based on gait performance is required for use and dissemination in daily life. The translational potential of this article The present review reveals the current state of the clinical effectiveness of WREs for gait reconstruction in patients with SCI, contributing to evidence-based device application and further development.
Collapse
Affiliation(s)
- Koki Tan
- Graduate School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Soichiro Koyama
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Hiroaki Sakurai
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Toshio Teranishi
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Yoshikiyo Kanada
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Shigeo Tanabe
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
- Corresponding author.
| |
Collapse
|
10
|
Rodríguez-Fernández A, Lobo-Prat J, Font-Llagunes JM. Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments. J Neuroeng Rehabil 2021; 18:22. [PMID: 33526065 PMCID: PMC7852187 DOI: 10.1186/s12984-021-00815-5] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 01/12/2021] [Indexed: 02/08/2023] Open
Abstract
Gait disorders can reduce the quality of life for people with neuromuscular impairments. Therefore, walking recovery is one of the main priorities for counteracting sedentary lifestyle, reducing secondary health conditions and restoring legged mobility. At present, wearable powered lower-limb exoskeletons are emerging as a revolutionary technology for robotic gait rehabilitation. This systematic review provides a comprehensive overview on wearable lower-limb exoskeletons for people with neuromuscular impairments, addressing the following three questions: (1) what is the current technological status of wearable lower-limb exoskeletons for gait rehabilitation?, (2) what is the methodology used in the clinical validations of wearable lower-limb exoskeletons?, and (3) what are the benefits and current evidence on clinical efficacy of wearable lower-limb exoskeletons? We analyzed 87 clinical studies focusing on both device technology (e.g., actuators, sensors, structure) and clinical aspects (e.g., training protocol, outcome measures, patient impairments), and make available the database with all the compiled information. The results of the literature survey reveal that wearable exoskeletons have potential for a number of applications including early rehabilitation, promoting physical exercise, and carrying out daily living activities both at home and the community. Likewise, wearable exoskeletons may improve mobility and independence in non-ambulatory people, and may reduce secondary health conditions related to sedentariness, with all the advantages that this entails. However, the use of this technology is still limited by heavy and bulky devices, which require supervision and the use of walking aids. In addition, evidence supporting their benefits is still limited to short-intervention trials with few participants and diversity among their clinical protocols. Wearable lower-limb exoskeletons for gait rehabilitation are still in their early stages of development and randomized control trials are needed to demonstrate their clinical efficacy.
Collapse
Affiliation(s)
- Antonio Rodríguez-Fernández
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain. .,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.
| | - Joan Lobo-Prat
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain.,Institut de Robòtica i Informàtica Industrial, CSIC-UPC, Llorens i Artigas 4-6, 08028, Barcelona, Spain
| | - Josep M Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain
| |
Collapse
|
11
|
Paek AY, Brantley JA, Sujatha Ravindran A, Nathan K, He Y, Eguren D, Cruz-Garza JG, Nakagome S, Wickramasuriya DS, Chang J, Rashed-Al-Mahfuz M, Amin MR, Bhagat NA, Contreras-Vidal JL. A Roadmap Towards Standards for Neurally Controlled End Effectors. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2021; 2:84-90. [PMID: 35402986 PMCID: PMC8979628 DOI: 10.1109/ojemb.2021.3059161] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 12/24/2020] [Accepted: 02/09/2021] [Indexed: 12/02/2022] Open
Abstract
The control and manipulation of various types of end effectors such as powered exoskeletons, prostheses, and ‘neural’ cursors by brain-machine interface (BMI) systems has been the target of many research projects. A seamless “plug and play” interface between any BMI and end effector is desired, wherein similar user's intent cause similar end effectors to behave identically. This report is based on the outcomes of an IEEE Standards Association Industry Connections working group on End Effectors for Brain-Machine Interfacing that convened to identify and address gaps in the existing standards for BMI-based solutions with a focus on the end-effector component. A roadmap towards standardization of end effectors for BMI systems is discussed by identifying current device standards that are applicable for end effectors. While current standards address basic electrical and mechanical safety, and to some extent, performance requirements, several gaps exist pertaining to unified terminologies, data communication protocols, patient safety and risk mitigation.
Collapse
Affiliation(s)
| | - Justin A Brantley
- University of Houston Houston TX 77204 USA
- Department of BioengineeringUniversity of Pennsylvania Philadelphia PA 19104 USA
| | | | | | | | | | - Jesus G Cruz-Garza
- University of Houston Houston TX 77204 USA
- Department of Design and Environmental AnalysisCornell University Ithaca NY 14853 USA
| | | | | | | | - Md Rashed-Al-Mahfuz
- University of Houston Houston TX 77204 USA
- Department of Computer Science and EngineeringUniversity of Rajshahi Rajshahi 6205 Bangladesh
| | | | - Nikunj A Bhagat
- University of Houston Houston TX 77204 USA
- Feinstein Institutes for Medical Research Manhasset NY 11030 USA
| | | |
Collapse
|
12
|
Delgado AD, Escalon MX, Bryce TN, Weinrauch W, Suarez SJ, Kozlowski AJ. Safety and feasibility of exoskeleton-assisted walking during acute/sub-acute SCI in an inpatient rehabilitation facility: A single-group preliminary study. J Spinal Cord Med 2020; 43:657-666. [PMID: 31603395 PMCID: PMC7534310 DOI: 10.1080/10790268.2019.1671076] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Context/objective: Information on the safety and feasibility of lower extremity powered exoskeletons for persons with acute/sub-acute spinal cord injury (SCI) is limited. Understanding the safety and feasibility of employing powered exoskeletons in acute/sub-acute (<6 months post injury) at a SCI acute inpatient rehabilitation (SCI-AIR) facility could guide clinical practice and provide a basis for larger clinical trials on efficacy and effectiveness. Design: Single group observational study. Setting: SCI-AIR. Participants: Participants (n = 12; age: 28-71 years; 58% AIS D; 58% male) with neurological levels of injuries ranging from C2 to L3. Interventions: Up to 90 min of exoskeleton-assisted locomotor training was provided up to three times per week during SCI-AIR. Outcome measures: Safety of device use during inpatient locomotor training was quantified as the number of adverse events (AE) per device exposure hour. Feasibility of device use was defined in terms of protocol compliance, intensity, and proficiency. Results: Concerning safety, symptomatic hypotension was the most common AE reported at 111-events/exoskeleton-hours. Protocol compliance had a mean (SD) of 54% (30%). For intensity, 77% of participants incorporated variable assistance into at least 1 walking session; 70% of participants' sessions were completed with a higher RPE than the physical therapist. In proficiency, 58% achieved at least minimal assistance when walking with the device. Conclusion: Exoskeleton training in SCI-AIR can be safe and feasible for newly injured individuals with SCI who have clinically defined ambulatory goals. Nonetheless, sufficient controls to minimize risks for AEs, such as hypotensive events, are required.
Collapse
Affiliation(s)
- Andrew D. Delgado
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York City, New York, USA,The Graduate School, Icahn School of Medicine at Mount Sinai, New York City, New York, USA,Correspondence to: Andrew D. Delgado, Department of Rehabilitation Medicine and Human Performance, Icahn School of Medicine at Mount Sinai, 1 Gustave L. Levy Place, New York, New York10029, USA; Ph: 212-241-9478.
| | - Miguel X. Escalon
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
| | - Thomas N. Bryce
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
| | - William Weinrauch
- Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
| | - Stephanie J. Suarez
- Sports Therapy and Rehabilitation Services (STARS), Northwell Health, East Meadow, New York, USA
| | - Allan J. Kozlowski
- Department of Epidemiology and Biostatistics, Michigan State University, Grand Rapids, Michigan, USA,John F. Butzer Center for Research & Innovation, Mary Free Bed Rehabilitation Hospital, Grand Rapids, Michigan, USA
| |
Collapse
|
13
|
Hong E, Gorman PH, Forrest GF, Asselin PK, Knezevic S, Scott W, Wojciehowski SB, Kornfeld S, Spungen AM. Mobility Skills With Exoskeletal-Assisted Walking in Persons With SCI: Results From a Three Center Randomized Clinical Trial. Front Robot AI 2020; 7:93. [PMID: 33501260 PMCID: PMC7805715 DOI: 10.3389/frobt.2020.00093] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 06/09/2020] [Indexed: 11/17/2022] Open
Abstract
Background: Clinical exoskeletal-assisted walking (EAW) programs for individuals with spinal cord injury (SCI) have been established, but many unknown variables remain. These include addressing staffing needs, determining the number of sessions needed to achieve a successful walking velocity milestone for ambulation, distinguishing potential achievement goals according to level of injury, and deciding the number of sessions participants need to perform in order to meet the Food and Drug Administration (FDA) criteria for personal use prescription in the home and community. The primary aim of this study was to determine the number of sessions necessary to achieve adequate EAW skills and velocity milestones, and the percentage of participants able to achieve these skills by 12 sessions and to determine the skill progression over the course of 36 sessions. Methods: A randomized clinical trial (RCT) was conducted across three sites, in persons with chronic (≥6 months) non-ambulatory SCI. Eligible participants were randomized (within site) to either the EAW arm first (Group 1), three times per week for 36 sessions, striving to be completed in 12 weeks or the usual activity arm (UA) first (Group 2), followed by a crossover to the other arm for both groups. The 10-meter walk test seconds (s) (10MWT), 6-min walk test meters (m) (6MWT), and the Timed-Up-and-Go (s) (TUG) were performed at 12, 24, and 36 sessions. To test walking performance in the exoskeletal devices, nominal velocities and distance milestones were chosen prior to study initiation, and were used for the 10MWT (≤ 40s), 6MWT (≥80m), and TUG (≤ 90s). All walking tests were performed with the exoskeletons. Results: A total of 50 participants completed 36 sessions of EAW training. At 12 sessions, 31 (62%), 35 (70%), and 36 (72%) participants achieved the 10MWT, 6MWT, and TUG milestones, respectively. By 36 sessions, 40 (80%), 41 (82%), and 42 (84%) achieved the 10MWT, 6MWT, and TUG criteria, respectively. Conclusions: It is feasible to train chronic non-ambulatory individuals with SCI in performance of EAW sufficiently to achieve reasonable mobility skill outcome milestones.
Collapse
Affiliation(s)
- EunKyoung Hong
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY, United States.,Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Peter H Gorman
- Department of Neurology, University of Maryland School of Medicine and Chief, Division of Rehabilitation Medicine, University of Maryland Rehabilitation and Orthopaedic Institute, Baltimore, MD, United States
| | - Gail F Forrest
- Center for Spinal Stimulation and Center for Mobility and Rehabilitation Engineering, Kessler Foundation, West Orange, NJ, United States.,Physical Medicine & Rehabilitation, Rutgers New Jersey Medical School, Newark, NJ, United States
| | - Pierre K Asselin
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY, United States.,Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Steven Knezevic
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY, United States
| | - William Scott
- Department of Neurology, University of Maryland School of Medicine and VA Maryland Healthcare System, Baltimore, MD, United States
| | - Sandra Buffy Wojciehowski
- Center for Spinal Stimulation and Center for Mobility and Rehabilitation Engineering, Kessler Foundation, West Orange, NJ, United States.,Performance Exercise Attitude and Knowledge Center, Craig Hospital, Englewood, CO, United States
| | - Stephen Kornfeld
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY, United States.,Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Ann M Spungen
- Spinal Cord Damage Research Center, James J. Peters VA Medical Center, Bronx, NY, United States.,Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY, United States.,Department of Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| |
Collapse
|
14
|
Bass A, Morin SN, Vermette M, Aubertin-Leheudre M, Gagnon DH. Incidental bilateral calcaneal fractures following overground walking with a wearable robotic exoskeleton in a wheelchair user with a chronic spinal cord injury: is zero risk possible? Osteoporos Int 2020; 31:1007-1011. [PMID: 31932962 DOI: 10.1007/s00198-020-05277-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 01/01/2020] [Indexed: 01/19/2023]
Abstract
Many individuals with spinal cord injury (SCI) rely on wheelchairs as their primary mode of locomotion leading to reduced weight-bearing on the lower extremities, which contributes to severe bone loss and increased risk of fragility fractures. Engaging in a walking program may reverse this vicious cycle, as this promotes lower extremity weight-bearing and mobility, which may reduce bone loss and fragility fracture risk. However, fragility fracture risk associated with the use of wearable robotic exoskeletons (WREs) in individuals with SCI needs consideration. A 35-year-old man with chronic complete sensorimotor SCI (neurological level = T6) and low initial bone mineral density enrolled in a 6- to 8-week WRE-assisted walking program after successfully completing an initial clinical screening process and two familiarization sessions with the WRE. However, after the first training session with the WRE, he developed bilateral localized ankle edema. Training was suspended, and a CT-scan revealed bilateral calcaneal fractures, which healed with conservative treatment over a 12-week period. Opportunities for improving clinical screening and WRE design are explored. The relevance of developing clinical practice guidelines for safe initiation and progression of intensity during WRE-assisted walking programs is highlighted. This case of bilateral calcaneal fractures illustrates that aiming for "zero risk" during WRE-assisted walking programs may not be realistic. Although WREs are a relatively new technology, current evidence confirms their potential to greatly improve health and quality of life in individuals with chronic SCI. Hence, ensuring their safe use remains a key priority.
Collapse
Affiliation(s)
- A Bass
- School of Rehabilitation, Faculty of Medicine, Université de Montréal, Montreal, QC, Canada
- Pathokinesiology Laboratory, Centre for Interdisciplinary Research in Rehabilitation of Greater Montreal (CRIR) of the Centre Intégré Universitaire de Santé et Services Sociaux (CIUSSS) du Centre-Sud-de-l'Île-de-Montréal, Montreal, QC, Canada
| | - S N Morin
- Department of Medicine, McGill University, Montreal, QC, Canada
| | - M Vermette
- Pathokinesiology Laboratory, Centre for Interdisciplinary Research in Rehabilitation of Greater Montreal (CRIR) of the Centre Intégré Universitaire de Santé et Services Sociaux (CIUSSS) du Centre-Sud-de-l'Île-de-Montréal, Montreal, QC, Canada
| | - M Aubertin-Leheudre
- Department of Exercise Science, Université du Québec à Montréal, Montreal, QC, Canada
| | - D H Gagnon
- School of Rehabilitation, Faculty of Medicine, Université de Montréal, Montreal, QC, Canada.
- Pathokinesiology Laboratory, Centre for Interdisciplinary Research in Rehabilitation of Greater Montreal (CRIR) of the Centre Intégré Universitaire de Santé et Services Sociaux (CIUSSS) du Centre-Sud-de-l'Île-de-Montréal, Montreal, QC, Canada.
| |
Collapse
|
15
|
Heinemann AW, Kinnett-Hopkins D, Mummidisetty CK, Bond RA, Ehrlich-Jones L, Furbish C, Field-Fote E, Jayaraman A. Appraisals of robotic locomotor exoskeletons for gait: focus group insights from potential users with spinal cord injuries. Disabil Rehabil Assist Technol 2020; 15:762-772. [PMID: 32255369 DOI: 10.1080/17483107.2020.1745910] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Purpose: To describe appraisals of robotic exoskeletons for locomotion by potential users with spinal cord injuries, their perceptions of device benefits and limitations, and recommendations for manufacturers and therapists regarding device use.Materials and methods: We conducted focus groups at three regional rehabilitation hospitals and used thematic analysis to define themes.Results: Across four focus groups, 35 adults participated; they were predominantly middle-aged, male, and diverse in terms of race and ethnicity, well educated, and not working. Participants had been living with SCI an average of two decades. Most participants were aware of exoskeletons. Some were enthusiastic about the usability of the devices while others were more circumspect. They had many questions about device affordability and usability, and were discerning in their appraisal of benefits and suitability to their particular circumstances. They reflected on device cost, the need for caregiver assistance, use of hands, and environmental considerations. They weighed the functional benefits relative to the cost of preferred activities. Their recommendations focused on cost, battery life, and independent use.Conclusions: Potential users' appraisals of mobility technology reflect a nuanced appreciation of device costs; functional, social, and psychological benefits; and limitations. Results provide guidance to therapists and manufacturers regarding device use.Implications for RehabilitationPotential users of robotic locomotor exoskeletons with spinal cord injuries appreciate the functional, social, and psychological benefits that these devices may offer.Their appraisals reflect nuanced consideration of device cost and features, and the suitability of the assistive technology to their circumstances.They recommend that manufacturers focus on reducing cost, extending battery life, and features that allow independent use.
Collapse
Affiliation(s)
- Allen W Heinemann
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA.,Center for Rehabilitation Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, USA
| | | | | | - Rachel A Bond
- Center for Rehabilitation Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, USA
| | - Linda Ehrlich-Jones
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA.,Center for Rehabilitation Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, USA
| | - Catherine Furbish
- Spinal Cord Injury Research Program, Shepherd Center, Atlanta, GA, USA
| | - Edelle Field-Fote
- Spinal Cord Injury Research Program, Shepherd Center, Atlanta, GA, USA.,Division of Physical Therapy, Emory University, Atlanta, GA, USA
| | - Arun Jayaraman
- Center for Rehabilitation Outcomes Research, Shirley Ryan AbilityLab, Chicago, IL, USA
| |
Collapse
|
16
|
Systemic inflammation in traumatic spinal cord injury. Exp Neurol 2019; 325:113143. [PMID: 31843491 DOI: 10.1016/j.expneurol.2019.113143] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 12/06/2019] [Accepted: 12/10/2019] [Indexed: 01/08/2023]
|
17
|
Changes in bowel function following exoskeletal-assisted walking in persons with spinal cord injury: an observational pilot study. Spinal Cord 2019; 58:459-466. [PMID: 31822808 PMCID: PMC7145720 DOI: 10.1038/s41393-019-0392-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 11/19/2019] [Accepted: 11/21/2019] [Indexed: 01/15/2023]
Abstract
Study Design Prospective, observational study Objective To explore the effects of exoskeleton-assisted walking (EAW) on bowel function in persons with spinal cord injury (SCI). Setting Ambulatory research facility located in a tertiary care hospital Methods Individuals 18–65 years of age, with thoracic vertebrae one (T1) to T11 motor-complete paraplegia of at least 12 months duration were enrolled. Pre- and post-EAW training, participants were asked to report on various aspects of their bowel function as well as on their overall quality of life (QOL) as related to their bowel function. Results Ten participants completed 25–63 sessions of EAW over a period of 12 to 14 weeks, one participant was lost to follow up due to early withdrawal after 10 sessions. Due to the small sample size, each participant’s results were presented descriptively in a case series format. At least 5/10 participants reported improvements with frequency of bowel evacuations, less time spent on bowel management per bowel day, fewer bowel accidents per month, reduced laxative and/or stool softener use, and improved overall satisfaction with their bowel program post-EAW training. Furthermore, 8/10 reported improved stool consistency and 7/10 reported improved bowel function related QOL. One participant reported worsening of bowel function post-EAW. Conclusion Between 50 and 80% of the participants studied reported improvements in bowel function and/or management post-EAW training. EAW training appeared to mitigate SCI-related bowel dysfunction and the potential benefits of EAW on bowel function after SCI is worthy or further study. Sponsorship N/A
Collapse
|
18
|
Khan AS, Livingstone DC, Hurd CL, Duchcherer J, Misiaszek JE, Gorassini MA, Manns PJ, Yang JF. Retraining walking over ground in a powered exoskeleton after spinal cord injury: a prospective cohort study to examine functional gains and neuroplasticity. J Neuroeng Rehabil 2019; 16:145. [PMID: 31752911 PMCID: PMC6868817 DOI: 10.1186/s12984-019-0585-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Accepted: 08/30/2019] [Indexed: 12/12/2022] Open
Abstract
Background Powered exoskeletons provide a way to stand and walk for people with severe spinal cord injury. Here, we used the ReWalk exoskeleton to determine the training dosage required for walking proficiency, the sensory and motor changes in the nervous system with training, and the functionality of the device in a home-like environment. Methods Participants with chronic (> 1 yr) motor complete or incomplete spinal cord injury, who were primarily wheelchair users, were trained to walk in the ReWalk for 12 weeks. Measures were taken before, during, immediately after, and 2–3 months after training. Measures included walking progression, sitting balance, skin sensation, spasticity, and strength of the corticospinal tracts. Results Twelve participants were enrolled with 10 completing training. Training progression and walking ability: The progression in training indicated about 45 sessions to reach 80% of final performance in training. By the end of training, participants walked at speeds of 0.28–0.60 m/s, and distances of 0.74–1.97 km in 1 h. The effort of walking was about 3.3 times that for manual wheelchair propulsion. One non-walker with an incomplete injury became a walker without the ReWalk after training. Sensory and motor measures: Sitting balance was improved in some, as seen from the limits of stability and sway speed. Neuropathic pain showed no long term changes. Change in spasticity was mixed with suggestion of differences between those with high versus low spasticity prior to training. The strength of motor pathways from the brain to back extensor muscles remained unchanged. Adverse events: Minor adverse events were encountered by the participants and trainer (skin abrasions, non-injurious falls). Field testing: The majority of participants could walk on uneven surfaces outdoors. Some limitations were encountered in home-like environments. Conclusion For individuals with severe SCI, walking proficiency in the ReWalk requires about 45 sessions of training. The training was accompanied by functional improvements in some, especially in people with incomplete injuries. Trial registration NCT02322125 Registered 22 December 2014. Electronic supplementary material The online version of this article (10.1186/s12984-019-0585-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Atif S Khan
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada
| | - Donna C Livingstone
- Department of Physical Therapy, University of Alberta, 2-50 Corbett Hall, Edmonton, AB, T6G 2G4, Canada
| | - Caitlin L Hurd
- Department of Physical Therapy, University of Alberta, 2-50 Corbett Hall, Edmonton, AB, T6G 2G4, Canada
| | | | - John E Misiaszek
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada.,Occupational Therapy, University of Alberta, Edmonton, Alberta, Canada
| | - Monica A Gorassini
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada.,Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Patricia J Manns
- Department of Physical Therapy, University of Alberta, 2-50 Corbett Hall, Edmonton, AB, T6G 2G4, Canada
| | - Jaynie F Yang
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada. .,Department of Physical Therapy, University of Alberta, 2-50 Corbett Hall, Edmonton, AB, T6G 2G4, Canada.
| |
Collapse
|
19
|
Zleik N, Weaver F, Harmon RL, Le B, Radhakrishnan R, Jirau-Rosaly WD, Craven BC, Raiford M, Hill JN, Etingen B, Guihan M, Heggeness MH, Ray C, Carbone L. Prevention and management of osteoporosis and osteoporotic fractures in persons with a spinal cord injury or disorder: A systematic scoping review. J Spinal Cord Med 2019; 42:735-759. [PMID: 29745791 PMCID: PMC6830234 DOI: 10.1080/10790268.2018.1469808] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Objectives: The primary objective was to review the literature regarding methodologies to assess fracture risk, to prevent and treat osteoporosis and to manage osteoporotic fractures in SCI/D.Study Design: Scoping review.Settings/Participants: Human adult subjects with a SCI/D.Outcome measures: Strategies to identify persons with SCI/D at risk for osteoporotic fractures, nonpharmacological and pharmacological therapies for osteoporosis and management of appendicular fractures.Results: 226 articles were included in the scoping review. Risk of osteoporotic fractures in SCI is predicted by a combination of DXA-defined low BMD plus clinical and demographic characteristics. Screening for secondary causes of osteoporosis, in particular hyperparathyroidism, hyperthyroidism, vitamin D insufficiency and hypogonadism, should be considered. Current antiresorptive therapies for treatment of osteoporosis have limited efficacy. Use of surgery to treat fractures has increased and outcomes are good and comparable to conservative treatment in most cases. A common adverse event following fracture was delayed healing.Conclusions: Most of the research in this area is limited by small sample sizes, weak study designs, and significant variation in populations studied. Future research needs to address cohort definition and study design issues.
Collapse
Affiliation(s)
- Nour Zleik
- Charlie Norwood Veterans Administration Medical Center, Augusta, Georgia, USA
- Department of Medicine, Division of Rheumatology, Medical College of Georgia at Augusta University, Augusta, Georgia, USA
| | - Frances Weaver
- Center of Innovation for Complex Chronic Healthcare (CINCCH), Health Services Research & Development, Department of Veterans Affairs, Hines VA Hospital, Hines, Illinois, USA
- Department of Public Health Sciences, Stritch School of Medicine, Loyola University, Maywood, Illinois, USA
| | - Robert L. Harmon
- Charlie Norwood Veterans Administration Medical Center, Augusta, Georgia, USA
| | - Brian Le
- Charlie Norwood Veterans Administration Medical Center, Augusta, Georgia, USA
- Department of Medicine, Division of Rheumatology, Medical College of Georgia at Augusta University, Augusta, Georgia, USA
| | | | - Wanda D. Jirau-Rosaly
- Department of Medicine, Division of Geriatrics, Medical College of Georgia at Augusta University, Augusta, Georgia, USA
| | - B. Catharine Craven
- Department of Medicine, Division of Physical Medicine and Rehabilitation, University of Toronto, Toronto, Ontario, Canada
| | - Mattie Raiford
- School of Medicine, Medical College of Georgia at Augusta University, Augusta, Georgia, USA
| | - Jennifer N. Hill
- Department of Public Health Sciences, Stritch School of Medicine, Loyola University, Maywood, Illinois, USA
| | - Bella Etingen
- Center of Innovation for Complex Chronic Healthcare (CINCCH), Health Services Research & Development, Department of Veterans Affairs, Hines VA Hospital, Hines, Illinois, USA
| | - Marylou Guihan
- Center of Innovation for Complex Chronic Healthcare (CINCCH), Health Services Research & Development, Department of Veterans Affairs, Hines VA Hospital, Hines, Illinois, USA
| | - Michael H. Heggeness
- Department of Orthopaedic Surgery, University of Kansas School of Medicine, Wichita, Kansas, USA
| | - Cara Ray
- Center of Innovation for Complex Chronic Healthcare (CINCCH), Health Services Research & Development, Department of Veterans Affairs, Hines VA Hospital, Hines, Illinois, USA
- Department of Public Health Sciences, Stritch School of Medicine, Loyola University, Maywood, Illinois, USA
| | - Laura Carbone
- Charlie Norwood Veterans Administration Medical Center, Augusta, Georgia, USA
- Department of Medicine, Division of Rheumatology, Medical College of Georgia at Augusta University, Augusta, Georgia, USA
| |
Collapse
|
20
|
Experience of Robotic Exoskeleton Use at Four Spinal Cord Injury Model Systems Centers. J Neurol Phys Ther 2019; 42:256-267. [PMID: 30199518 DOI: 10.1097/npt.0000000000000235] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND AND PURPOSE Refinement of robotic exoskeletons for overground walking is progressing rapidly. We describe clinicians' experiences, evaluations, and training strategies using robotic exoskeletons in spinal cord injury rehabilitation and wellness settings and describe clinicians' perceptions of exoskeleton benefits and risks and developments that would enhance utility. METHODS We convened focus groups at 4 spinal cord injury model system centers. A court reporter took verbatim notes and provided a transcript. Research staff used a thematic coding approach to summarize discussions. RESULTS Thirty clinicians participated in focus groups. They reported using exoskeletons primarily in outpatient and wellness settings; 1 center used exoskeletons during inpatient rehabilitation. A typical episode of outpatient exoskeleton therapy comprises 20 to 30 sessions and at least 2 staff members are involved in each session. Treatment focuses on standing, stepping, and gait training; therapists measure progress with standardized assessments. Beyond improved gait, participants attributed physiological, psychological, and social benefits to exoskeleton use. Potential risks included falls, skin irritation, and disappointed expectations. Participants identified enhancements that would be of value including greater durability and adjustability, lighter weight, 1-hand controls, ability to navigate stairs and uneven surfaces, and ability to balance without upper extremity support. DISCUSSION AND CONCLUSIONS Each spinal cord injury model system center had shared and distinct practices in terms of how it integrates robotic exoskeletons into physical therapy services. There is currently little evidence to guide integration of exoskeletons into rehabilitation therapy services and a pressing need to generate evidence to guide practice and to inform patients' expectations as more devices enter the market.Video Abstract available for more insights from the authors (see Video, Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A231).
Collapse
|
21
|
Muijzer-Witteveen H, Sibum N, van Dijsseldonk R, Keijsers N, van Asseldonk E. Questionnaire results of user experiences with wearable exoskeletons and their preferences for sensory feedback. J Neuroeng Rehabil 2018; 15:112. [PMID: 30470238 PMCID: PMC6260663 DOI: 10.1186/s12984-018-0445-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 10/18/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Wearable exoskeletons can be a powerful tool for the facilitation of ambulation of complete Spinal Cord Injury (SCI) subjects, which has several psychological and physical advantages. However, exoskeleton control is difficult for this group of users and requires a long period of training. People with SCI not only lack the motor control, but also miss the sensory information from below the level of the lesion, which is for example very important in their perception of body posture and makes balancing with an exoskeleton difficult. It is hypothesized that through sensory substitution part of the missing sensory information can be provided and might thereby improve the control of an exoskeleton. However, it is not known which information would be most important to receive while using an exoskeleton and how this feedback should be provided. METHODS To investigate the preferences of users of an exoskeleton, a questionnaire was filled out by 10 SCI subjects who underwent a training program with a commercial exoskeleton (ReWalk). The questionnaire consisted of questions about the use of the exoskeleton to identify which information is missing and which instructions from the therapists were needed to be able to control the exoskeleton. The second part of the questionnaire focused on the possibilities of sensory feedback and preferences for stimulation methods (auditory, vibrotactile or visual) and feedback timing (discrete or continuous) were investigated. Furthermore, six options for feedback parameters (step initiation, continuous and discrete gait phases, foot position and mediolateral and anteroposterior weight shift) were proposed and the respondents were asked to indicate their preferences. RESULTS Three feedback parameters (feedback about mediolateral and anteroposterior weight shift and feedback about step initiation) were considered as possibly helpful by the respondents. Furthermore, there were slight preferences for the use of vibrotactile (over auditory and visual) and discrete (over continuous) feedback. CONCLUSIONS The answers of the respondents on the optimal feedback parameters were rather variable and therefore it is recommended to let the users choose their preferred feedback system during a training session with several feedback options. However, there are slight preferences for the use of vibrotactile stimulation provided in a discrete way.
Collapse
Affiliation(s)
- Heidi Muijzer-Witteveen
- Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, the Netherlands.
| | - Nienke Sibum
- Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, the Netherlands
| | | | - Noël Keijsers
- Research, Sint Maartenskliniek, Hengstdal 3, Nijmegen, 6574 NA, the Netherlands
| | - Edwin van Asseldonk
- Biomechanical Engineering, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, the Netherlands
| |
Collapse
|
22
|
Wang J, Li X, Huang TH, Yu S, Li Y, Chen T, Carriero A, Oh-Park M, Su H. Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton. IEEE Robot Autom Lett 2018. [DOI: 10.1109/lra.2018.2864352] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
23
|
Palermo AE, Maher JL, Baunsgaard CB, Nash MS. Clinician-Focused Overview of Bionic Exoskeleton Use After Spinal Cord Injury. Top Spinal Cord Inj Rehabil 2018; 23:234-244. [PMID: 29339899 DOI: 10.1310/sci2303-234] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Spinal cord injury (SCI) resulting in paralysis of lower limbs and trunk restricts daily upright activity, work capacity, and ambulation ability, putting persons with an injury at greater risk of developing a myriad of secondary medical issues. Time spent in the upright posture has been shown to decrease the risk of these complications in SCI. Unfortunately, the majority of ambulation assistive technologies are limited by inefficiencies such as high energy demand, lengthy donning and doffing time, and poor gait pattern precluding widespread use. These limitations spurred the development of bionic exoskeletons. These devices are currently being used in rehabilitation settings for gait retraining, and some have been approved for home use. This overview will address the current state of available devices and their utility.
Collapse
Affiliation(s)
- Anne E Palermo
- The Miami Project to Cure Paralysis, University of Miami Miller School of Medicine, Miami, Florida
| | - Jennifer L Maher
- The Miami Project to Cure Paralysis, University of Miami Miller School of Medicine, Miami, Florida
| | | | - Mark S Nash
- The Miami Project to Cure Paralysis, University of Miami Miller School of Medicine, Miami, Florida.,Departments of Neurological Surgery and Physical Medicine & Rehabilitation, University of Miami Miller School of Medicine, Miami, Florida
| |
Collapse
|
24
|
Mekki M, Delgado AD, Fry A, Putrino D, Huang V. Robotic Rehabilitation and Spinal Cord Injury: a Narrative Review. Neurotherapeutics 2018; 15:604-617. [PMID: 29987763 PMCID: PMC6095795 DOI: 10.1007/s13311-018-0642-3] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Mobility after spinal cord injury (SCI) is among the top goals of recovery and improvement in quality of life. Those with tetraplegia rank hand function as the most important area of recovery in their lives, and those with paraplegia, walking. Without hand function, emphasis in rehabilitation is placed on accessing one's environment through technology. However, there is still much reliance on caretakers for many activities of daily living. For those with paraplegia, if incomplete, orthoses exist to augment walking function, but they require a significant amount of baseline strength and significant energy expenditure to use. Options for those with motor complete paraplegia have traditionally been limited to the wheelchair. While wheelchairs provide a modified level of independence, wheelchair users continue to face difficulties in access and mobility. In the past decade, research in SCI rehabilitation has expanded to include external motorized or robotic devices that initiate or augment movement. These robotic devices are used with 2 goals: to enhance recovery through repetitive, functional movement and increased neural plasticity and to act as a mobility aid beyond orthoses and wheelchairs. In addition, lower extremity exoskeletons have been shown to provide benefits to the secondary medical conditions after SCI such as pain, spasticity, decreased bone density, and neurogenic bowel. In this review, we discuss advances in robot-guided rehabilitation after SCI for the upper and lower extremities, as well as potential adjuncts to robotics.
Collapse
Affiliation(s)
- Marwa Mekki
- Department of Rehabilitation Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Andrew D Delgado
- Department of Rehabilitation Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Adam Fry
- Department of Rehabilitation Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - David Putrino
- Department of Rehabilitation Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Vincent Huang
- Department of Rehabilitation Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
| |
Collapse
|
25
|
Mazzoleni S, Battini E, Rustici A, Stampacchia G. An integrated gait rehabilitation training based on Functional Electrical Stimulation cycling and overground robotic exoskeleton in complete spinal cord injury patients: Preliminary results. IEEE Int Conf Rehabil Robot 2018; 2017:289-293. [PMID: 28813833 DOI: 10.1109/icorr.2017.8009261] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The aim of this study is to investigate the effects of an integrated gait rehabilitation training based on Functional Electrical Stimulation (FES)-cycling and overground robotic exoskeleton in a group of seven complete spinal cord injury patients on spasticity and patient-robot interaction. They underwent a robot-assisted rehabilitation training based on two phases: n=20 sessions of FES-cycling followed by n= 20 sessions of robot-assisted gait training based on an overground robotic exoskeleton. The following clinical outcome measures were used: Modified Ashworth Scale (MAS), Numerical Rating Scale (NRS) on spasticity, Penn Spasm Frequency Scale (PSFS), Spinal Cord Independence Measure Scale (SCIM), NRS on pain and International Spinal Cord Injury Pain Data Set (ISCI). Clinical outcome measures were assessed before (T0) after (T1) the FES-cycling training and after (T2) the powered overground gait training. The ability to walk when using exoskeleton was assessed by means of 10 Meter Walk Test (10MWT), 6 Minute Walk Test (6MWT), Timed Up and Go test (TUG), standing time, walking time and number of steps. Statistically significant changes were found on the MAS score, NRS-spasticity, 6MWT, TUG, standing time and number of steps. The preliminary results of this study show that an integrated gait rehabilitation training based on FES-cycling and overground robotic exoskeleton in complete SCI patients can provide a significant reduction of spasticity and improvements in terms of patient-robot interaction.
Collapse
|
26
|
Schrade SO, Dätwyler K, Stücheli M, Studer K, Türk DA, Meboldt M, Gassert R, Lambercy O. Development of VariLeg, an exoskeleton with variable stiffness actuation: first results and user evaluation from the CYBATHLON 2016. J Neuroeng Rehabil 2018. [PMID: 29534730 PMCID: PMC5851253 DOI: 10.1186/s12984-018-0360-4] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Powered exoskeletons are a promising approach to restore the ability to walk after spinal cord injury (SCI). However, current exoskeletons remain limited in their walking speed and ability to support tasks of daily living, such as stair climbing or overcoming ramps. Moreover, training progress for such advanced mobility tasks is rarely reported in literature. The work presented here aims to demonstrate the basic functionality of the VariLeg exoskeleton and its ability to enable people with motor complete SCI to perform mobility tasks of daily life. METHODS VariLeg is a novel powered lower limb exoskeleton that enables adjustments to the compliance in the leg, with the objective of improving the robustness of walking on uneven terrain. This is achieved by an actuation system with variable mechanical stiffness in the knee joint, which was validated through test bench experiments. The feasibility and usability of the exoskeleton was tested with two paraplegic users with motor complete thoracic lesions at Th4 and Th12. The users trained three times a week, in 60 min sessions over four months with the aim of participating in the CYBATHLON 2016 competition, which served as a field test for the usability of the exoskeleton. The progress on basic walking skills and on advanced mobility tasks such as incline walking and stair climbing is reported. Within this first study, the exoskeleton was used with a constant knee stiffness. RESULTS Test bench evaluation of the variable stiffness actuation system demonstrate that the stiffness could be rendered with an error lower than 30 Nm/rad. During training with the exoskeleton, both users acquired proficient skills in basic balancing, walking and slalom walking. In advanced mobility tasks, such as climbing ramps and stairs, only basic (needing support) to intermediate (able to perform task independently in 25% of the attempts) skill levels were achieved. After 4 months of training, one user competed at the CYBATHLON 2016 and was able to perform 3 (stand-sit-stand, slalom and tilted path) out of 6 obstacles of the track. No adverse events occurred during the training or the competition. CONCLUSION Demonstration of the applicability to restore ambulation for people with motor complete SCI was achieved. The CYBATHLON highlighted the importance of training and gaining experience in piloting an exoskeleton, which were just as important as the technical realization of the robot.
Collapse
Affiliation(s)
- Stefan O Schrade
- Product Development Group Zurich, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland.
| | - Katrin Dätwyler
- Rehabilitation Engineering Laboratory, ETH Zurich, Lengghalde 5, Zurich, 8092, Switzerland
| | - Marius Stücheli
- Rehabilitation Engineering Laboratory, ETH Zurich, Lengghalde 5, Zurich, 8092, Switzerland
| | - Kathrin Studer
- Product Development Group Zurich, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland
| | - Daniel-Alexander Türk
- Rehabilitation Engineering Laboratory, ETH Zurich, Lengghalde 5, Zurich, 8092, Switzerland
| | - Mirko Meboldt
- Product Development Group Zurich, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland
| | - Roger Gassert
- Product Development Group Zurich, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland
| | - Olivier Lambercy
- Rehabilitation Engineering Laboratory, ETH Zurich, Lengghalde 5, Zurich, 8092, Switzerland
| |
Collapse
|
27
|
Muijzer-Witteveen HJB, Nataletti S, Agnello M, Casadio M, van Asseldonk EHF. Vibrotactile feedback to control the amount of weight shift during walking - A first step towards better control of an exoskeleton for spinal cord injury subjects. IEEE Int Conf Rehabil Robot 2018; 2017:1482-1487. [PMID: 28814029 DOI: 10.1109/icorr.2017.8009457] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
People with Spinal Cord Injury do not only lack the ability to control their muscles, but also miss the sensory information from below the level of their lesion. Therefore, it may become difficult for them to perceive the state of the body during walking, which is however often used to control wearable exoskeletons. In the present study the possibilities of providing vibrotactile feedback about the Center of Mass (CoM) during walking were investigated. The results showed that healthy subjects could successfully interpret the provided vibrotactile cues and change their walking pattern accordingly. Vibrotactile stimulation was either provided in a concurrent (over the complete CoM movement) or terminal (only when the desired CoM displacement was reached) way. The latter led to a better accuracy and can be easily implemented in a wearable exoskeleton where a certain amount of CoM displacement is needed to initiate stepping.
Collapse
|
28
|
Locomotor training using an overground robotic exoskeleton in long-term manual wheelchair users with a chronic spinal cord injury living in the community: Lessons learned from a feasibility study in terms of recruitment, attendance, learnability, performance and safety. J Neuroeng Rehabil 2018; 15:12. [PMID: 29490678 PMCID: PMC5831695 DOI: 10.1186/s12984-018-0354-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Accepted: 02/15/2018] [Indexed: 02/07/2023] Open
Abstract
Background For individuals who sustain a complete motor spinal cord injury (SCI) and rely on a wheelchair as their primary mode of locomotion, overground robotic exoskeletons represent a promising solution to stand and walk again. Although overground robotic exoskeletons have gained tremendous attention over the past decade and are now being transferred from laboratories to clinical settings, their effects remain unclear given the paucity of scientific evidence and the absence of large-scale clinical trials. This study aims to examine the feasibility of a locomotor training program with an overground robotic exoskeleton in terms of recruitment, attendance, and drop-out rates as well as walking performance, learnability, and safety. Methods Individuals with a SCI were invited to participate in a 6 to 8-week locomotor training program with a robotic exoskeleton encompassing 18 sessions. Selected participants underwent a comprehensive screening process and completed two familiarization sessions with the robotic exoskeleton. The outcome measures were the rate of recruitment of potential participants, the rate of attendance at training sessions, the rate of drop-outs, the ability to walk with the exoskeleton, and its progression over the program as well as the adverse events. Results Out of 49 individuals who expressed their interest in participating in the study, only 14 initiated the program (recruitment rate = 28.6%). Of these, 13 individuals completed the program (drop-out rate = 7.1%) and attended 17.6 ± 1.1 sessions (attendance rate = 97.9%). Their greatest standing time, walking time, and number of steps taken during a session were 64.5 ± 10.2 min, 47.2 ± 11.3 min, and 1843 ± 577 steps, respectively. During the training program, these last three parameters increased by 45.3%, 102.1%, and 248.7%, respectively. At the end of the program, when walking with the exoskeleton, most participants required one therapist (85.7%), needed stand-by or contact-guard assistance (57.1%), used forearm crutches (71.4%), and reached a walking speed of 0.25 ± 0.05 m/s. Five participants reported training-related pain or stiffness in the upper extremities during the program. One participant sustained bilateral calcaneal fractures and stopped the program. Conclusions This study confirms that larger clinical trials investigating the effects of a locomotor training program with an overground robotic exoskeleton are feasible and relatively safe in individuals with complete motor SCI. Moreover, to optimize the recruitment rate and safety in future trials, this study now highlights the need of developing pre-training rehabilitation programs to increase passive lower extremity range of motion and standing tolerance. This study also calls for the development of clinical practice guidelines targeting fragility fracture risk assessment linked to the use of overground robotic exoskeletons.
Collapse
|
29
|
Bissolotti L, Nicoli F, Picozzi M. Domestic Use of the Exoskeleton for Gait Training in Patients with Spinal Cord Injuries: Ethical Dilemmas in Clinical Practice. Front Neurosci 2018; 12:78. [PMID: 29497359 PMCID: PMC5818425 DOI: 10.3389/fnins.2018.00078] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Accepted: 01/31/2018] [Indexed: 11/22/2022] Open
Affiliation(s)
- Luciano Bissolotti
- Rehabilitation Service, Casa di Cura Domus Salutis, Fondazione Teresa Camplani, Brescia, Italy
| | - Federico Nicoli
- Biotechnology and Life Sciences Department, Center for Clinical Ethics, Insubria University, Varese, Italy.,Clinical Ethics Service, Domus Salutis Clinic, Teresa Camplani Foundation, Brescia, Italy
| | - Mario Picozzi
- Biotechnology and Life Sciences Department, Center for Clinical Ethics, Insubria University, Varese, Italy
| |
Collapse
|
30
|
Sozzi S, Crisafulli O, Schieppati M. Haptic Cues for Balance: Use of a Cane Provides Immediate Body Stabilization. Front Neurosci 2017; 11:705. [PMID: 29311785 PMCID: PMC5735113 DOI: 10.3389/fnins.2017.00705] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 12/01/2017] [Indexed: 11/13/2022] Open
Abstract
Haptic cues are important for balance. Knowledge of the temporal features of their effect may be crucial for the design of neural prostheses. Touching a stable surface with a fingertip reduces body sway in standing subjects eyes closed (EC), and removal of haptic cue reinstates a large sway pattern. Changes in sway occur rapidly on changing haptic conditions. Here, we describe the effects and time-course of stabilization produced by a haptic cue derived from a walking cane. We intended to confirm that cane use reduces body sway, to evaluate the effect of vision on stabilization by a cane, and to estimate the delay of the changes in body sway after addition and withdrawal of haptic input. Seventeen healthy young subjects stood in tandem position on a force platform, with eyes closed or open (EO). They gently lowered the cane onto and lifted it from a second force platform. Sixty trials per direction of haptic shift (Touch → NoTouch, T-NT; NoTouch → Touch, NT-T) and visual condition (EC-EO) were acquired. Traces of Center of foot Pressure (CoP) and the force exerted by cane were filtered, rectified, and averaged. The position in space of a reflective marker positioned on the cane tip was also acquired by an optoelectronic device. Cross-correlation (CC) analysis was performed between traces of cane tip and CoP displacement. Latencies of changes in CoP oscillation in the frontal plane EC following the T-NT and NT-T haptic shift were statistically estimated. The CoP oscillations were larger in EC than EO under both T and NT (p < 0.001) and larger during NT than T conditions (p < 0.001). Haptic-induced effect under EC (Romberg quotient NT/T ~ 1.2) was less effective than that of vision under NT condition (EC/EO ~ 1.5) (p < 0.001). With EO cane had little effect. Cane displacement lagged CoP displacement under both EC and EO. Latencies to changes in CoP oscillations were longer after addition (NT-T, about 1.6 s) than withdrawal (T-NT, about 0.9 s) of haptic input (p < 0.001). These latencies were similar to those occurring on fingertip touch, as previously shown. Overall, data speak in favor of substantial equivalence of the haptic information derived from both “direct” fingertip contact and “indirect” contact with the floor mediated by the cane. Cane, finger and visual inputs would be similarly integrated in the same neural centers for balance control. Haptic input from a walking aid and its processing time should be considered when designing prostheses for locomotion.
Collapse
Affiliation(s)
- Stefania Sozzi
- Centro Studi Attività Motorie, Istituti Clinici Scientifici Maugeri SPA SB, Institute of Pavia, IRCCS, Pavia, Italy
| | - Oscar Crisafulli
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics and Maternal Child Health, University of Genoa, Genoa, Italy
| | - Marco Schieppati
- Department of Exercise and Sport Science, LUNEX International University of Health, Exercise and Sports, Differdange, Luxembourg
| |
Collapse
|
31
|
Feasibility and Safety of a Powered Exoskeleton for Assisted Walking for Persons With Multiple Sclerosis: A Single-Group Preliminary Study. Arch Phys Med Rehabil 2017; 98:1300-1307. [DOI: 10.1016/j.apmr.2017.02.010] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 01/18/2017] [Accepted: 02/06/2017] [Indexed: 12/20/2022]
|