1
|
Wei Z, Athertya JS, Chung CB, Bydder GM, Chang EY, Du J, Yang W, Ma Y. Qualitative and Quantitative MR Imaging of the Cartilaginous Endplate: A Review. J Magn Reson Imaging 2025; 61:1552-1571. [PMID: 39165086 PMCID: PMC11839955 DOI: 10.1002/jmri.29562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 07/26/2024] [Accepted: 07/26/2024] [Indexed: 08/22/2024] Open
Abstract
The cartilaginous endplate (CEP) plays a pivotal role in facilitating the supply of nutrients and, transport of metabolic waste, as well as providing mechanical support for the intervertebral disc (IVD). Recent technological advances have led to a surge in MR imaging studies focused on the CEP. This article describes the anatomy and functions of the CEP as well as MRI techniques for both qualitative and quantitative assessment of the CEP. Effective CEP MR imaging sequences require two key features: high spatial resolution and relatively short echo time. High spatial resolution spoiled gradient echo (SPGR) and ultrashort echo time (UTE) sequences, fulfilling these requirements, are the basis for most of the sequences employed in CEP imaging. This article reviews existing sequences for qualitative CEP imaging, such as the fat-suppressed SPGR and UTE, dual-echo subtraction UTE, inversion recovery prepared and fat-suppressed UTE, and dual inversion recovery prepared UTE sequences. These sequences are employed together with other techniques for quantitative CEP imaging, including measurements of T2*, T2, T1, T1ρ, magnetization transfer, perfusion, and diffusion tensor parameters. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Zhao Wei
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
- Department of Radiology, University of California San Diego, CA, United States
| | - Jiyo S. Athertya
- Department of Radiology, University of California San Diego, CA, United States
| | - Christine B. Chung
- Department of Radiology, University of California San Diego, CA, United States
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
| | - Graeme M. Bydder
- Department of Radiology, University of California San Diego, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California San Diego, CA, United States
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, CA, United States
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
- Department of Bioengineering, University of California San Diego, CA, USA
| | - Wenhui Yang
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Yajun Ma
- Department of Radiology, University of California San Diego, CA, United States
| |
Collapse
|
2
|
Warden SJ, Coburn SL, Fuchs RK, Surowiec RK, Carballido-Gamio J, Kemp JL, Jalaie PK, Hanff DF, Palmer AJR, Fernquest SJ, Crossley KM, Heerey JJ. Asymptomatic female softball pitchers have altered hip morphology and cartilage composition. Sci Rep 2025; 15:3262. [PMID: 39863740 PMCID: PMC11762768 DOI: 10.1038/s41598-025-87839-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Accepted: 01/22/2025] [Indexed: 01/27/2025] Open
Abstract
Few studies have explored hip morphology and cartilage composition in female athletes or the impact of asymmetric repetitive loading, such as occurs during softball pitching. The current cross-sectional study assessed bilateral bony hip morphology on computed tomography imaging in collegiate-level softball pitchers ('Pitch1', n = 25) and cross-country runners ('Run', n = 13). Magnetic resonance imaging was used to assess cartilage relaxation times in a second cohort of pitchers ('Pitch2', n = 10) and non-athletic controls ('Con', n = 4). Pitch1 had 52% greater maximum alpha angle than Run (p < 0.001) and were 21.3 (95% CI 2.4 to 192.0) times more likely to have an alpha angle ≥ 60° within at least one hip. Pitch2 had longer T2 relaxation times in the superior femoral cartilage of the drive leg (same side as the throwing arm) and stride leg than Con (all p < 0.02). The drive leg in Pitch2 had longer T1ρ and T2 relaxation times in the superior femoral cartilage compared to the stride leg (all p ≤ 0.03). Asymptomatic softball pitchers exhibit altered bony hip morphology and cartilage composition compared to cross-country runners and non-athletic controls, respectively. They also exhibit asymmetry in cartilage composition. Further studies with larger sample sizes are warranted and any potential long-term consequences of the changes in terms of symptom and osteoarthritis development requires investigation.
Collapse
Affiliation(s)
- Stuart J Warden
- Department of Physical Therapy, School of Health and Human Sciences, Indiana University Indianapolis, 1050 Wishard Blvd, RG-3147, Indianapolis, IN, 46202, USA.
| | - Sally L Coburn
- La Trobe Sport & Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
| | - Robyn K Fuchs
- Tom and Julia Wood College of Osteopathic Medicine, Marian University, Indianapolis, IN, USA
| | - Rachel K Surowiec
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Julio Carballido-Gamio
- Department of Radiology, School of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO, USA
| | - Joanne L Kemp
- La Trobe Sport & Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
| | - Peter K Jalaie
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - David F Hanff
- Department of Radiology and Nuclear Medicine, Erasmus University Medical Centre, Rotterdam, The Netherlands
| | - Antony J R Palmer
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Scott J Fernquest
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Kay M Crossley
- La Trobe Sport & Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
| | - Joshua J Heerey
- La Trobe Sport & Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
| |
Collapse
|
3
|
Han C, Xu H, Gao H, Liu F, Wu J, Liu Y, Cheng Y, Deng W, Yue X, Wu Z, Yu Y, Zhao R, Han Y, Li X. Effect of spin-lock frequency on quantitative myocardial T1ρ mapping. Insights Imaging 2024; 15:176. [PMID: 38992330 PMCID: PMC11239636 DOI: 10.1186/s13244-024-01762-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 06/24/2024] [Indexed: 07/13/2024] Open
Abstract
OBJECTIVES To use T1ρ mapping to assess myocardial fibrosis and to provide a reference for future clinical application, it is necessary to understand the factors influencing T1ρ values. This study explored the influence of different spin-locking frequencies on T1ρ values under a 3.0-T MR system. METHODS Fifty-seven healthy subjects were prospectively and consecutively included in this study, and T1ρ mapping was performed on them in 3 short-axis slices with three spin-lock frequencies at the amplitude of 300 Hz, 400 Hz, and 500 Hz, then nine T1ρ images were acquired per subject. Four T1ρ-weighted images were acquired using a spin-lock preparation pulse with varying durations (0 msec, 13.3 msec, 26.6 msec, 40 msec). T1ρ relaxation times were quantified for each slice and each myocardial segment. The results were analyzed using Student's t-test and one-way analysis of variance (ANOVA) methods. RESULTS Mean T1ρ relaxation times were 43.5 ± 2.8 msec at 300 Hz, 44.9 ± 3.6 msec at 400 Hz, and 46.2 ± 3.1 msec at 500 Hz, showing a significant progressive increase from low to high spin-lock frequency (300 Hz vs. 400 Hz, p = 0.046; 300 Hz vs. 500 Hz, p < 0.001; 400 Hz vs. 500 Hz, p = 0.043). In addition, The T1ρ values of females were significantly higher than those of males (300 Hz, p = 0.049; 400 Hz, p = 0.01; 500 Hz, p = 0.002). CONCLUSION In this prospective study, myocardial T1ρ values for the specific CMR setting are provided, and we found that gender and spin-lock frequency can affect the T1ρ values. CRITICAL RELEVANCE STATEMENT T1ρ mapping could supersede late gadolinium enhancement for detection of myocardial fibrosis. Establishing reference mean values that take key technical elements into account will facilitate interpretation of data in disease states. KEY POINTS This study established myocardial T1ρ reference values for different spin-lock frequencies. T1ρ values increased with spin-lock frequency, but numerical differences were minimal. Females had higher T1ρ values than males at all frequencies.
Collapse
Affiliation(s)
- Caiyun Han
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | - Huimin Xu
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | - Hui Gao
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | - Fang Liu
- Department of Cardiology, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, 230022, Hefei, China
| | - Jian Wu
- Department of Cardiology, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, 230022, Hefei, China
| | - Yan Liu
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | - Yong Cheng
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | - Wei Deng
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China
| | | | | | - Yongqiang Yu
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China.
| | - Ren Zhao
- Department of Cardiology, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, 230022, Hefei, China.
| | - Yuchi Han
- Cardiovascular Division, Wexner Medical Center, College of Medicine, the Ohio State University Medical Center, Columbus, Ohio, USA
| | - Xiaohu Li
- Department of Radiology, the First Affiliated Hospital of Anhui Medical University; Research Center of Clinical Medical Imaging; Anhui Province Clinical Image Quality Control Center, Hefei, 230032, Anhui Province, China.
| |
Collapse
|
4
|
Lemainque T, Pridöhl N, Zhang S, Huppertz M, Post M, Yüksel C, Yoneyama M, Prescher A, Kuhl C, Truhn D, Nebelung S. Time-efficient combined morphologic and quantitative joint MRI: an in situ study of standardized knee cartilage defects in human cadaveric specimens. Eur Radiol Exp 2024; 8:66. [PMID: 38834751 DOI: 10.1186/s41747-024-00462-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Accepted: 03/27/2024] [Indexed: 06/06/2024] Open
Abstract
BACKGROUND Quantitative techniques such as T2 and T1ρ mapping allow evaluating the cartilage and meniscus. We evaluated multi-interleaved X-prepared turbo-spin echo with intuitive relaxometry (MIXTURE) sequences with turbo spin-echo (TSE) contrast and additional parameter maps versus reference TSE sequences in an in situ model of human cartilage defects. METHODS Standardized cartilage defects of 8, 5, and 3 mm in diameter were created in the lateral femora of ten human cadaveric knee specimens (81 ± 10 years old; nine males, one female). MIXTURE sequences providing proton density-weighted fat-saturated images and T2 maps or T1-weighted images and T1ρ maps as well as the corresponding two- and three-dimensional TSE reference sequences were acquired before and after defect creation (3-T scanner; knee coil). Defect delineability, bone texture, and cartilage relaxation times were quantified. Appropriate parametric or non-parametric tests were used. RESULTS Overall, defect delineability and texture features were not significantly different between the MIXTURE and reference sequences (p ≤ 0.47). After defect creation, relaxation times significantly increased in the central femur (T2pre = 51 ± 4 ms [mean ± standard deviation] versus T2post = 56 ± 4 ms; p = 0.002) and all regions combined (T1ρpre = 40 ± 4 ms versus T1ρpost = 43 ± 4 ms; p = 0.004). CONCLUSIONS MIXTURE permitted time-efficient simultaneous morphologic and quantitative joint assessment based on clinical image contrasts. While providing T2 or T1ρ maps in clinically feasible scan time, morphologic image features, i.e., cartilage defects and bone texture, were comparable between MIXTURE and reference sequences. RELEVANCE STATEMENT Equally time-efficient and versatile, the MIXTURE sequence platform combines morphologic imaging using familiar contrasts, excellent image correspondence versus corresponding reference sequences and quantitative mapping information, thereby increasing the diagnostic value beyond mere morphology. KEY POINTS • Combined morphologic and quantitative MIXTURE sequences are based on three-dimensional TSE contrasts. • MIXTURE sequences were studied in an in situ human cartilage defect model. • Morphologic image features, i.e., defect delineabilty and bone texture, were investigated. • Morphologic image features were similar between MIXTURE and reference sequences. • MIXTURE allowed time-efficient simultaneous morphologic and quantitative knee joint assessment.
Collapse
Affiliation(s)
- Teresa Lemainque
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany.
| | - Nicola Pridöhl
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | - Shuo Zhang
- Philips GmbH Market DACH, Hamburg, Germany
| | - Marc Huppertz
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | - Manuel Post
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | - Can Yüksel
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | | | - Andreas Prescher
- Institute of Molecular and Cellular Anatomy, RWTH Aachen University, Aachen, 52074, Germany
| | - Christiane Kuhl
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | - Daniel Truhn
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| | - Sven Nebelung
- Department of Diagnostic and Interventional Radiology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, Aachen, 52074, Germany
| |
Collapse
|
5
|
Guo Y, Guo T, Huang C, Sun P, Wu Z, Jin Z, Zheng C, Li X. Combining T1rho and advanced diffusion MRI for noninvasively staging liver fibrosis: an experimental study in rats. Abdom Radiol (NY) 2024; 49:1881-1891. [PMID: 38607572 PMCID: PMC11213740 DOI: 10.1007/s00261-024-04327-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 03/30/2024] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE To investigate the value of imaging parameters derived from T1 relaxation times in the rotating frame (T1ρ or T1rho), diffusion kurtosis imaging (DKI) and intravoxel incoherent motion (IVIM) in assessment of liver fibrosis in rats and propose an optimal diagnostic model based on multiparametric MRI. METHODS Thirty rats were divided into one control group and four fibrosis experimental groups (n = 6 for each group). Liver fibrosis was induced by administering thioacetamide (TAA) for 2, 4, 6, and 8 weeks. T1ρ, mean kurtosis (MK), mean diffusivity (MD), perfusion fraction (f), true diffusion coefficient (D), and pseudo-diffusion coefficient (D*) were measured and compared among different fibrosis stages. An optimal diagnostic model was established and the diagnostic efficiency was evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS The mean AUC values, sensitivity, and specificity of T1ρ and MD derived from DKI across all liver fibrosis stages were comparable but much higher than those of other imaging parameters (0.954, 92.46, 91.85 for T1ρ; 0.949, 92.52, 91.24 for MD). The model combining T1ρ and MD exhibited better diagnostic performance with higher AUC values than any individual method for staging liver fibrosis (≥ F1: 1.000 (0.884-1.000); ≥ F2: 0.935 (0.782-0.992); ≥ F3: 0.982 (0.852-1.000); F4: 0.986 (0.859-1.000)). CONCLUSION Among the evaluated imaging parameters, T1ρ and MD were superior for differentiating varying liver fibrosis stages. The model combining T1ρ and MD was promising to be a credible diagnostic biomarker to detect and accurately stage liver fibrosis.
Collapse
Affiliation(s)
- Yiwan Guo
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, China
| | - Tingting Guo
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, China
| | - Chen Huang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
| | - Peng Sun
- Clinical & Technical Support, Philips Healthcare, No. 1628, Zhongshan Road, Wuhan, China
| | - Zhigang Wu
- Clinical & Technical Support, Philips Healthcare, No. 1628, Zhongshan Road, Wuhan, China
| | - Ziwei Jin
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, China
| | - Chuansheng Zheng
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, China
| | - Xin Li
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, 430022, China.
| |
Collapse
|
6
|
Malhi BS, Jang H, Malhi MS, Berry DB, Jerban S. Tendon evaluation with ultrashort Echo Time (UTE) MRI: A Systematic Review. FRONTIERS IN MUSCULOSKELETAL DISORDERS 2024; 2:1324050. [PMID: 39867448 PMCID: PMC11759502 DOI: 10.3389/fmscd.2024.1324050] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2025]
Abstract
Tendon disease ranks among the leading reasons patients consult their general practitioners, comprising approximately one-third of musculoskeletal appointments. Magnetic resonance imaging (MRI) is regarded as the gold standard for assessing tendons. Due to their short transverse relaxation time (T2), Tendons show up as a signal void in conventional MRI scans, which employ sequences with echo times (TEs) around several milliseconds. Ultrashort echo time (UTE) sequences utilize TEs that are 100-1,000 times shorter than those used in conventional sequences. This enables the direct visualization of tendons and assessment of their relaxation times, which is the basis for quantitative MRI. A systematic review was conducted on publications after 1990 in Google Scholar and PubMed databases. The search terms "ultrashort echo time," "tendon," and "UTE" were used to identify studies related to this investigation. This review discussed the current knowledge in quantitative UTE-MRI imaging of tendons. Quantitative UTE-T1, UTE-T2*, UTE-MT, and UTE-T1ρ techniques were described, and their reported applications in the literature were summarized in this review. We also discussed the advantages and challenges of these techniques and how these quantitative biomarkers may change in response to tendon pathology.
Collapse
Affiliation(s)
- Bhavsimran Singh Malhi
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| | | | - David B. Berry
- Department of Orthopaedic Surgery, University of California, San Diego, San Diego, CA, United States
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
| |
Collapse
|
7
|
Piccolo CL, Mallio CA, Vaccarino F, Grasso RF, Zobel BB. Imaging of knee osteoarthritis: a review of multimodal diagnostic approach. Quant Imaging Med Surg 2023; 13:7582-7595. [PMID: 37969633 PMCID: PMC10644136 DOI: 10.21037/qims-22-1392] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 03/22/2023] [Indexed: 11/17/2023]
Abstract
Knee osteoarthritis (KOA) is a common chronic condition among the elderly population that significantly affects the quality of life. Imaging is crucial in the diagnosis, evaluation, and management of KOA. This manuscript reviews the various imaging modalities available until now, with a little focus on the recent developments with Artificial Intelligence. Currently, radiography is the first-line imaging modality recommended for the diagnosis of KOA, owing to its wide availability, affordability, and ability to provide a clear view of bony components of the knee. Although radiography is useful in assessing joint space narrowing (JSN), osteophytes and subchondral sclerosis, it has limited effectiveness in detecting early cartilage damage, soft tissue abnormalities and synovial inflammation. Ultrasound is a safe and affordable imaging technique that can provide information on cartilage thickness, synovial fluid, JSN and osteophytes, though its ability to evaluate deep structures such as subchondral bone is limited. Magnetic resonance imaging (MRI) represents the optimal imaging modality to assess soft tissue structures. New MRI techniques are able to detect early cartilage damage measuring the T1ρ and T2 relaxation time of knee cartilage. Delayed gadolinium-enhanced MRI of cartilage, by injecting a contrast agent to enhance the visibility of the cartilage on MRI scans, can provide information about its integrity. Despite these techniques can provide valuable information about the biochemical composition of knee cartilage and can help detect early signs of osteoarthritis (OA), they may not be widely available. Computed tomography (CT) has restricted utility in evaluating OA; nonetheless, weight-bearing CT imaging, using the joint space mapping technique, exhibits potential in quantifying knee joint space width and detecting structural joint ailments. PET-MRI is a hybrid imaging technique able to combine morphological information on bone and soft tissue alterations with the biochemical changes, but more research is needed to justify its high cost and time involved. The new tools of artificial intelligence, including machine learning models, can assist in detecting patterns and correlations in KOA that may be useful in the diagnosis, grading, predicting the need for arthroplasty, and improving surgical accuracy.
Collapse
Affiliation(s)
- Claudia Lucia Piccolo
- Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Roma, Italy
| | - Carlo Augusto Mallio
- Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Roma, Italy
- Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Roma, Italy
| | - Federica Vaccarino
- Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Roma, Italy
| | - Rosario Francesco Grasso
- Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Roma, Italy
- Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Roma, Italy
| | - Bruno Beomonte Zobel
- Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Roma, Italy
- Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Roma, Italy
| |
Collapse
|
8
|
Bustin A, Witschey WRT, van Heeswijk RB, Cochet H, Stuber M. Magnetic resonance myocardial T1ρ mapping : Technical overview, challenges, emerging developments, and clinical applications. J Cardiovasc Magn Reson 2023; 25:34. [PMID: 37331930 DOI: 10.1186/s12968-023-00940-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 05/15/2023] [Indexed: 06/20/2023] Open
Abstract
The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.
Collapse
Affiliation(s)
- Aurelien Bustin
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France.
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | | | - Ruud B van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hubert Cochet
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - Matthias Stuber
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|
9
|
Wang P. Adiabatically prepared spin-lock could reduce the R 1ρ dispersion. Quant Imaging Med Surg 2023; 13:763-775. [PMID: 36819267 PMCID: PMC9929376 DOI: 10.21037/qims-21-959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/07/2022] [Indexed: 12/14/2022]
Abstract
Background R1ρ (or spin-lock) imaging is prone to artifacts arising from field inhomogeneities that may impact the R1ρ quantification. Previous research has proposed two types of method to manage the artifacts in continuous-wave constant amplitude spin-lock, one is based on the composite block pulses to compensate for the field imperfections, another category uses adiabatic pulses in the R1ρ pre-pulse to excite and reverse the magnetization (named adiabatic prepared approach). Although both methods have proved their efficiency in alleviating artifacts, we observed that the adiabatic pulse approach could produce much lower R1ρ dispersion in human knee cartilage than the block pulse method (characterized by the R1ρ difference ∆R1ρ =11.4 Hz (from spin-lock field 50 to 500 Hz) for the block pulse method vs. ∆R1ρ =4.5 Hz for the adiabatic pulse approach). Prompted by this observation, the purpose of this study was to investigate the underlying factors that may affect the R1ρ dispersion through numerical simulations based on the two-pool exchanging Bloch-McConnell equations. Methods The effects of free water pool size Pa (from 0.80 to 0.95), chemical exchange rate kb (from the bound to free water pool, ranged from 500 to 3,000 Hz), adiabatic pulse duration Tp (from 5.0 to 25 ms), and the chemical shift of the bound pool ppmb (from 1.0 to 5.0 ppm) were examined on the degree of the R1ρ dispersion for the two R1ρ imaging methods. Results In general, the greater the ppmb, kb, Tp, and the smaller Pa, the more significant difference in R1ρ dispersion between the block and adiabatic approaches, with the dispersion curve of the adiabatic method becoming flatter. Conclusions The adiabatic prepared approach may compromise the R1ρ dispersion, the effect is determined by the combination of the tissue and radiofrequency (RF) pulse properties. It is suggested that care should be taken when using the adiabatically prepared approach to study R1ρ dispersion.
Collapse
|
10
|
Capiglioni M, Turco F, Wiest R, Kiefer C. Analysis of the robustness and dynamics of spin-locking preparations for the detection of oscillatory magnetic fields. Sci Rep 2022; 12:16965. [PMID: 36216858 PMCID: PMC9550815 DOI: 10.1038/s41598-022-21232-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 09/23/2022] [Indexed: 12/29/2022] Open
Abstract
Extracting quantitative information of neuronal signals by non-invasive imaging is an outstanding challenge for understanding brain function and pathology. However, state-of-the-art techniques offer low sensitivity to deep electrical sources. Stimulus induced rotary saturation is a recently proposed magnetic resonance imaging sequence that detects oscillatory magnetic fields using a spin-lock preparation. Phantom experiments and simulations proved its efficiency and sensitivity, but the susceptibility of the method to field inhomogeneities is still not well understood. In this study, we simulated and analyzed the dynamic of three spin-lock preparations and their response to field inhomogeneities in the presence of a resonant oscillating field. We show that the composite spin-lock preparation is more robust against field variations within the double resonance effect. In addition, we tested the capability of the chosen composite spin-lock preparation to recover information about the spectral components of a composite signal. This study sets the bases to move one step further towards the clinical application of MR-based neuronal current imaging.
Collapse
Affiliation(s)
- Milena Capiglioni
- grid.5734.50000 0001 0726 5157Institute for Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging (SCAN), University of Bern, Freiburgstrasse 16, 3010 Bern, Switzerland
| | - Federico Turco
- grid.5734.50000 0001 0726 5157Institute for Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging (SCAN), University of Bern, Freiburgstrasse 16, 3010 Bern, Switzerland
| | - Roland Wiest
- grid.5734.50000 0001 0726 5157Institute for Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging (SCAN), University of Bern, Freiburgstrasse 16, 3010 Bern, Switzerland
| | - Claus Kiefer
- grid.5734.50000 0001 0726 5157Institute for Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging (SCAN), University of Bern, Freiburgstrasse 16, 3010 Bern, Switzerland
| |
Collapse
|
11
|
Towards robust in vivo quantification of oscillating biomagnetic fields using Rotary Excitation based MRI. Sci Rep 2022; 12:15375. [PMID: 36100634 PMCID: PMC9469076 DOI: 10.1038/s41598-022-19275-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 08/26/2022] [Indexed: 11/28/2022] Open
Abstract
Spin-lock based functional magnetic resonance imaging (fMRI) has the potential for direct spatially-resolved detection of neuronal activity and thus may represent an important step for basic research in neuroscience. In this work, the corresponding fundamental effect of Rotary EXcitation (REX) is investigated both in simulations as well as in phantom and in vivo experiments. An empirical law for predicting optimal spin-lock pulse durations for maximum magnetic field sensitivity was found. Experimental conditions were established that allow robust detection of ultra-weak magnetic field oscillations with simultaneous compensation of static field inhomogeneities. Furthermore, this work presents a novel concept for the emulation of brain activity utilizing the built-in MRI gradient system, which allows REX sequences to be validated in vivo under controlled and reproducible conditions. Via transmission of Rotary EXcitation (tREX), we successfully detected magnetic field oscillations in the lower nano-Tesla range in brain tissue. Moreover, tREX paves the way for the quantification of biomagnetic fields.
Collapse
|
12
|
Gram M, Gensler D, Albertova P, Gutjahr FT, Lau K, Arias-Loza PA, Jakob PM, Nordbeck P. Quantification correction for free-breathing myocardial T 1ρ mapping in mice using a recursively derived description of a T 1ρ* relaxation pathway. J Cardiovasc Magn Reson 2022; 24:30. [PMID: 35534901 PMCID: PMC9082875 DOI: 10.1186/s12968-022-00864-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 04/07/2022] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Fast and accurate T1ρ mapping in myocardium is still a major challenge, particularly in small animal models. The complex sequence design owing to electrocardiogram and respiratory gating leads to quantification errors in in vivo experiments, due to variations of the T1ρ relaxation pathway. In this study, we present an improved quantification method for T1ρ using a newly derived formalism of a T1ρ* relaxation pathway. METHODS The new signal equation was derived by solving a recursion problem for spin-lock prepared fast gradient echo readouts. Based on Bloch simulations, we compared quantification errors using the common monoexponential model and our corrected model. The method was validated in phantom experiments and tested in vivo for myocardial T1ρ mapping in mice. Here, the impact of the breath dependent spin recovery time Trec on the quantification results was examined in detail. RESULTS Simulations indicate that a correction is necessary, since systematically underestimated values are measured under in vivo conditions. In the phantom study, the mean quantification error could be reduced from - 7.4% to - 0.97%. In vivo, a correlation of uncorrected T1ρ with the respiratory cycle was observed. Using the newly derived correction method, this correlation was significantly reduced from r = 0.708 (p < 0.001) to r = 0.204 and the standard deviation of left ventricular T1ρ values in different animals was reduced by at least 39%. CONCLUSION The suggested quantification formalism enables fast and precise myocardial T1ρ quantification for small animals during free breathing and can improve the comparability of study results. Our new technique offers a reasonable tool for assessing myocardial diseases, since pathologies that cause a change in heart or breathing rates do not lead to systematic misinterpretations. Besides, the derived signal equation can be used for sequence optimization or for subsequent correction of prior study results.
Collapse
Affiliation(s)
- Maximilian Gram
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Experimental Physics 5, University of Würzburg, Würzburg, Germany
| | - Daniel Gensler
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
- Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany
| | - Petra Albertova
- Experimental Physics 5, University of Würzburg, Würzburg, Germany
| | - Fabian Tobias Gutjahr
- Experimental Physics 5, University of Würzburg, Würzburg, Germany
- Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany
| | - Kolja Lau
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
| | - Paula-Anahi Arias-Loza
- Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
| | | | - Peter Nordbeck
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
- Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany.
| |
Collapse
|
13
|
MR-Guided Adaptive Radiotherapy for OAR Sparing in Head and Neck Cancers. Cancers (Basel) 2022; 14:cancers14081909. [PMID: 35454816 PMCID: PMC9028510 DOI: 10.3390/cancers14081909] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/24/2022] [Accepted: 03/29/2022] [Indexed: 01/06/2023] Open
Abstract
Simple Summary Normal tissue toxicities in head and neck cancer persist as a cause of decreased quality of life and are associated with poorer treatment outcomes. The aim of this article is to review organ at risk (OAR) sparing approaches available in MR-guided adaptive radiotherapy and present future developments which hope to improve treatment outcomes. Increasing the spatial conformity of dose distributions in radiotherapy is an important first step in reducing normal tissue toxicities, and MR-guided treatment devices presents a new opportunity to use biological information to drive treatment decisions on a personalized basis. Abstract MR-linac devices offer the potential for advancements in radiotherapy (RT) treatment of head and neck cancer (HNC) by using daily MR imaging performed at the time and setup of treatment delivery. This article aims to present a review of current adaptive RT (ART) methods on MR-Linac devices directed towards the sparing of organs at risk (OAR) and a view of future adaptive techniques seeking to improve the therapeutic ratio. This ratio expresses the relationship between the probability of tumor control and the probability of normal tissue damage and is thus an important conceptual metric of success in the sparing of OARs. Increasing spatial conformity of dose distributions to target volume and OARs is an initial step in achieving therapeutic improvements, followed by the use of imaging and clinical biomarkers to inform the clinical decision-making process in an ART paradigm. Pre-clinical and clinical findings support the incorporation of biomarkers into ART protocols and investment into further research to explore imaging biomarkers by taking advantage of the daily MR imaging workflow. A coherent understanding of this road map for RT in HNC is critical for directing future research efforts related to sparing OARs using image-guided radiotherapy (IGRT).
Collapse
|
14
|
Feng L, Ma D, Liu F. Rapid MR relaxometry using deep learning: An overview of current techniques and emerging trends. NMR IN BIOMEDICINE 2022; 35:e4416. [PMID: 33063400 PMCID: PMC8046845 DOI: 10.1002/nbm.4416] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 08/25/2020] [Accepted: 09/09/2020] [Indexed: 05/08/2023]
Abstract
Quantitative mapping of MR tissue parameters such as the spin-lattice relaxation time (T1 ), the spin-spin relaxation time (T2 ), and the spin-lattice relaxation in the rotating frame (T1ρ ), referred to as MR relaxometry in general, has demonstrated improved assessment in a wide range of clinical applications. Compared with conventional contrast-weighted (eg T1 -, T2 -, or T1ρ -weighted) MRI, MR relaxometry provides increased sensitivity to pathologies and delivers important information that can be more specific to tissue composition and microenvironment. The rise of deep learning in the past several years has been revolutionizing many aspects of MRI research, including image reconstruction, image analysis, and disease diagnosis and prognosis. Although deep learning has also shown great potential for MR relaxometry and quantitative MRI in general, this research direction has been much less explored to date. The goal of this paper is to discuss the applications of deep learning for rapid MR relaxometry and to review emerging deep-learning-based techniques that can be applied to improve MR relaxometry in terms of imaging speed, image quality, and quantification robustness. The paper is comprised of an introduction and four more sections. Section 2 describes a summary of the imaging models of quantitative MR relaxometry. In Section 3, we review existing "classical" methods for accelerating MR relaxometry, including state-of-the-art spatiotemporal acceleration techniques, model-based reconstruction methods, and efficient parameter generation approaches. Section 4 then presents how deep learning can be used to improve MR relaxometry and how it is linked to conventional techniques. The final section concludes the review by discussing the promise and existing challenges of deep learning for rapid MR relaxometry and potential solutions to address these challenges.
Collapse
Affiliation(s)
- Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Fang Liu
- Department of Radiology, Massachusetts General Hospital, Harvard University, Boston, Massachusetts
| |
Collapse
|
15
|
Novel Magnetic Resonance Imaging Tools for the Diagnosis of Degenerative Disc Disease: A Narrative Review. Diagnostics (Basel) 2022; 12:diagnostics12020420. [PMID: 35204509 PMCID: PMC8870820 DOI: 10.3390/diagnostics12020420] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/04/2022] [Accepted: 02/04/2022] [Indexed: 01/27/2023] Open
Abstract
Low back pain (LBP) is one of the leading causes of disability worldwide, with a significant socioeconomic burden on healthcare systems. It is mainly caused by degenerative disc disease (DDD), a progressive, chronic, and age-related process. With its capacity to accurately characterize intervertebral disc (IVD) and spinal morphology, magnetic resonance imaging (MRI) has been established as one of the most valuable tools in diagnosing DDD. However, existing technology cannot detect subtle changes in IVD tissue composition and cell metabolism. In this review, we summarized the state of the art regarding innovative quantitative MRI modalities that have shown the capacity to discriminate and quantify changes in matrix composition and integrity, as well as biomechanical changes in the early stages of DDD. Validation and implementation of this new technology in the clinical setting will allow for an early diagnosis of DDD and ideally guide conservative and regenerative treatments that may prevent the progression of the degenerative process rather than intervene at the latest stages of the disease.
Collapse
|
16
|
Wei Z, Lombardi AF, Lee RR, Wallace M, Masuda K, Chang EY, Du J, Bydder GM, Yang W, Ma YJ. Comprehensive assessment of in vivo lumbar spine intervertebral discs using a 3D adiabatic T 1ρ prepared ultrashort echo time (UTE-Adiab-T 1ρ) pulse sequence. Quant Imaging Med Surg 2022; 12:269-280. [PMID: 34993077 PMCID: PMC8666733 DOI: 10.21037/qims-21-308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 05/19/2021] [Indexed: 12/31/2022]
Abstract
BACKGROUND T1ρ has been extensively reported as a sensitive biomarker of biochemical changes in the nucleus pulposus (NP) and annulus fibrosis of intervertebral discs (IVDs). However, no T1ρ study of cartilaginous endplates (CEPs) has yet been reported because the relatively long echo times (TEs) of conventional clinical T1ρ sequences cannot effectively capture the fast-decaying magnetic resonance signals of CEPs, which have very short T2/T2*s. This can be overcome by using ultrashort echo time (UTE) T1ρ acquisitions. METHODS Seventeen subjects underwent UTE with adiabatic T1ρ preparation (UTE-Adiab-T1ρ) and T2-weighted fast spin echo imaging of their lumbar spines. Each IVD was manually segmented into seven regions (i.e., outer anterior annulus fibrosis, inner anterior annulus fibrosis, outer posterior annulus fibrosis, inner posterior annulus fibrosis, superior CEP, inferior CEP, and NP). T1ρ values of these sub-regions were correlated with IVD modified Pfirrmann grades and subjects' ages. In addition, T1ρ values were compared in subjects with and without low back pain (LBP). RESULTS Correlations of T1ρ values of the outer posterior annulus fibrosis, superior CEP, inferior CEP, and NP with modified Pfirrmann grades were significant (P<0.05) with R values of 0.51, 0.36, 0.38, and -0.94, respectively. Correlations of T1ρ values of the outer anterior annulus fibrosis, outer posterior annulus fibrosis, and NP with ages were significant with R equal to 0.52, 0.71, and -0.76, respectively. T1ρ differences of the outer posterior annulus fibrosis, inferior CEP, and NP between the subjects with and without LBP were significant (P=0.005, 0.020, and 0.000, respectively). CONCLUSIONS The UTE-Adiab-T1ρ sequence can quantify T1ρ of whole IVDs including CEPs. This is an advance, and of value for comprehensive assessment of IVD degeneration.
Collapse
Affiliation(s)
- Zhao Wei
- Department of Radiology, University of California San Diego, La Jolla, CA, USA;,Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China;,University of Chinese Academy of Sciences, Beijing, China
| | - Alecio F. Lombardi
- Department of Radiology, University of California San Diego, La Jolla, CA, USA;,Research Service, Veterans Affairs San Diego Healthcare System, La Jolla, CA, USA
| | - Roland R. Lee
- Department of Radiology, University of California San Diego, La Jolla, CA, USA
| | - Mark Wallace
- Department of Anesthesiology, University of California San Diego, La Jolla, CA, USA
| | - Koichi Masuda
- Department of Orthopedic Surgery, University of California San Diego, La Jolla, CA, USA
| | - Eric Y. Chang
- Department of Radiology, University of California San Diego, La Jolla, CA, USA;,Research Service, Veterans Affairs San Diego Healthcare System, La Jolla, CA, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, La Jolla, CA, USA
| | - Graeme M. Bydder
- Department of Radiology, University of California San Diego, La Jolla, CA, USA
| | - Wenhui Yang
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China;,University of Chinese Academy of Sciences, Beijing, China
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, La Jolla, CA, USA
| |
Collapse
|
17
|
Fast myocardial T 1ρ mapping in mice using k-space weighted image contrast and a Bloch simulation-optimized radial sampling pattern. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2021; 35:325-340. [PMID: 34491466 PMCID: PMC8995242 DOI: 10.1007/s10334-021-00951-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 07/26/2021] [Accepted: 07/27/2021] [Indexed: 12/17/2022]
Abstract
Purpose T1ρ dispersion quantification can potentially be used as a cardiac magnetic resonance index for sensitive detection of myocardial fibrosis without the need of contrast agents. However, dispersion quantification is still a major challenge, because T1ρ mapping for different spin lock amplitudes is a very time consuming process. This study aims to develop a fast and accurate T1ρ mapping sequence, which paves the way to cardiac T1ρ dispersion quantification within the limited measurement time of an in vivo study in small animals. Methods A radial spin lock sequence was developed using a Bloch simulation-optimized sampling pattern and a view-sharing method for image reconstruction. For validation, phantom measurements with a conventional sampling pattern and a gold standard sequence were compared to examine T1ρ quantification accuracy. The in vivo validation of T1ρ mapping was performed in N = 10 mice and in a reproduction study in a single animal, in which ten maps were acquired in direct succession. Finally, the feasibility of myocardial dispersion quantification was tested in one animal. Results The Bloch simulation-based sampling shows considerably higher image quality as well as improved T1ρ quantification accuracy (+ 56%) and precision (+ 49%) compared to conventional sampling. Compared to the gold standard sequence, a mean deviation of − 0.46 ± 1.84% was observed. The in vivo measurements proved high reproducibility of myocardial T1ρ mapping. The mean T1ρ in the left ventricle was 39.5 ± 1.2 ms for different animals and the maximum deviation was 2.1% in the successive measurements. The myocardial T1ρ dispersion slope, which was measured for the first time in one animal, could be determined to be 4.76 ± 0.23 ms/kHz. Conclusion This new and fast T1ρ quantification technique enables high-resolution myocardial T1ρ mapping and even dispersion quantification within the limited time of an in vivo study and could, therefore, be a reliable tool for improved tissue characterization. Supplementary Information The online version contains supplementary material available at 10.1007/s10334-021-00951-y.
Collapse
|
18
|
Liu Y, Ying L, Chen W, Cui ZX, Zhu Q, Liu X, Zheng H, Liang D, Zhu Y. Accelerating the 3D T 1ρ mapping of cartilage using a signal-compensated robust tensor principal component analysis model. Quant Imaging Med Surg 2021; 11:3376-3391. [PMID: 34341716 DOI: 10.21037/qims-20-790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 04/19/2021] [Indexed: 11/06/2022]
Abstract
Background Magnetic resonance (MR) quantitative T1ρ imaging has been increasingly used to detect the early stages of osteoarthritis. The small volume and curved surface of articular cartilage necessitate imaging with high in-plane resolution and thin slices for accurate T1ρ measurement. Compared with 2D T1ρ mapping, 3D T1ρ mapping is free from artifacts caused by slice cross-talk and has a thinner slice thickness and full volume coverage. However, this technique needs to acquire multiple T1ρ-weighted images with different spin-lock times, which results in a very long scan duration. It is highly expected that the scan time can be reduced in 3D T1ρ mapping without compromising the T1ρ quantification accuracy and precision. Methods To accelerate the acquisition of 3D T1ρ mapping without compromising the T1ρ quantification accuracy and precision, a signal-compensated robust tensor principal component analysis method was proposed in this paper. The 3D T1ρ-weighted images compensated at different spin-lock times were decomposed as a low-rank high-order tensor plus a sparse component. Poisson-disk random undersampling patterns were applied to k-space data in the phase- and partition-encoding directions in both retrospective and prospective experiments. Five volunteers were involved in this study. The fully sampled k-space data acquired from 3 volunteers were retrospectively undersampled at R=5.2, 7.7, and 9.7, respectively. Reference values were obtained from the fully sampled data. Prospectively undersampled data for R=5 and R=7 were acquired from 2 volunteers. Bland-Altman analyses were used to assess the agreement between the accelerated and reference T1ρ measurements. The reconstruction performance was evaluated using the normalized root mean square error and the median of the normalized absolute deviation (MNAD) of the reconstructed T1ρ-weighted images and the corresponding T1ρ maps. Results T1ρ parameter maps were successfully estimated from T1ρ-weighted images reconstructed using the proposed method for all accelerations. The accelerated T1ρ measurements and reference values were in good agreement for R=5.2 (T1ρ: 40.4±1.4 ms), R=7.7 (T1ρ: 40.4±2.1 ms), and R=9.7 (T1ρ: 40.9±2.2 ms) in the Bland-Altman analyses. The T1ρ parameter maps reconstructed from the prospectively undersampled data also showed promising image quality using the proposed method. Conclusions The proposed method achieves the 3D T1ρ mapping of in vivo knee cartilage in eight minutes using a signal-compensated robust tensor principal component analysis method in image reconstruction.
Collapse
Affiliation(s)
- Yuanyuan Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,National Innovation Center for Advanced Medical Devices, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China.,Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Leslie Ying
- Department of Biomedical Engineering and Department of Electrical Engineering, University at Buffalo, The State University of New York, Buffalo, New York, USA
| | - Weitian Chen
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Shatin, Hong Kong, China
| | - Zhuo-Xu Cui
- Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qingyong Zhu
- Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yanjie Zhu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
19
|
Berry DB, Englund EK, Chen S, Frank LR, Ward SR. Medical imaging of tissue engineering and regenerative medicine constructs. Biomater Sci 2021; 9:301-314. [PMID: 32776044 PMCID: PMC8262082 DOI: 10.1039/d0bm00705f] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Advancement of tissue engineering and regenerative medicine (TERM) strategies to replicate tissue structure and function has led to the need for noninvasive assessment of key outcome measures of a construct's state, biocompatibility, and function. Histology based approaches are traditionally used in pre-clinical animal experiments, but are not always feasible or practical if a TERM construct is going to be tested for human use. In order to transition these therapies from benchtop to bedside, rigorously validated imaging techniques must be utilized that are sensitive to key outcome measures that fulfill the FDA standards for TERM construct evaluation. This review discusses key outcome measures for TERM constructs and various clinical- and research-based imaging techniques that can be used to assess them. Potential applications and limitations of these techniques are discussed, as well as resources for the processing, analysis, and interpretation of biomedical images.
Collapse
Affiliation(s)
- David B Berry
- Departments of NanoEngineering, University of California, San Diego, USA.
| | | | | | | | | |
Collapse
|
20
|
Ma S, Wang N, Fan Z, Kaisey M, Sicotte NL, Christodoulou AG, Li D. Three-dimensional whole-brain simultaneous T1, T2, and T1ρ quantification using MR Multitasking: Method and initial clinical experience in tissue characterization of multiple sclerosis. Magn Reson Med 2020; 85:1938-1952. [PMID: 33107126 DOI: 10.1002/mrm.28553] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To develop a 3D whole-brain simultaneous T1/T2/T1ρ quantification method with MR Multitasking that provides high quality, co-registered multiparametric maps in 9 min. METHODS MR Multitasking conceptualizes T1/T2/T1ρ relaxations as different time dimensions, simultaneously resolving all three dimensions with a low-rank tensor image model. The proposed method was validated on a phantom and in healthy volunteers, comparing quantitative measurements against corresponding reference methods and evaluating the scan-rescan repeatability. Initial clinical validation was performed in age-matched relapsing-remitting multiple sclerosis (RRMS) patients to examine the feasibility of quantitative tissue characterization and to compare with the healthy control cohort. The feasibility of synthesizing six contrast-weighted images was also examined. RESULTS Our framework produced high quality, co-registered T1/T2/T1ρ maps that closely resemble the reference maps. Multitasking T1/T2/T1ρ measurements showed substantial agreement with reference measurements on the phantom and in healthy controls. Bland-Altman analysis indicated good in vivo repeatability of all three parameters. In RRMS patients, lesions were conspicuously delineated on all three maps and on four synthetic weighted images (T2-weighted, T2-FLAIR, double inversion recovery, and a novel "T1ρ-FLAIR" contrast). T1 and T2 showed significant differences for normal appearing white matter between patients and controls, while T1ρ showed significant differences for normal appearing white matter, cortical gray matter, and deep gray matter. The combination of three parameters significantly improved the differentiation between RRMS patients and healthy controls, compared to using any single parameter alone. CONCLUSION MR Multitasking simultaneously quantifies whole-brain T1/T2/T1ρ and is clinically promising for quantitative tissue characterization of neurological diseases, such as MS.
Collapse
Affiliation(s)
- Sen Ma
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Nan Wang
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Marwa Kaisey
- Department of Neurology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Nancy L Sicotte
- Department of Neurology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Anthony G Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| |
Collapse
|
21
|
Enabling early detection of osteoarthritis from presymptomatic cartilage texture maps via transport-based learning. Proc Natl Acad Sci U S A 2020; 117:24709-24719. [PMID: 32958644 DOI: 10.1073/pnas.1917405117] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Many diseases have no visual cues in the early stages, eluding image-based detection. Today, osteoarthritis (OA) is detected after bone damage has occurred, at an irreversible stage of the disease. Currently no reliable method exists for OA detection at a reversible stage. We present an approach that enables sensitive OA detection in presymptomatic individuals. Our approach combines optimal mass transport theory with statistical pattern recognition. Eighty-six healthy individuals were selected from the Osteoarthritis Initiative, with no symptoms or visual signs of disease on imaging. On 3-y follow-up, a subset of these individuals had progressed to symptomatic OA. We trained a classifier to differentiate progressors and nonprogressors on baseline cartilage texture maps, which achieved a robust test accuracy of 78% in detecting future symptomatic OA progression 3 y prior to symptoms. This work demonstrates that OA detection may be possible at a potentially reversible stage. A key contribution of our work is direct visualization of the cartilage phenotype defining predictive ability as our technique is generative. We observe early biochemical patterns of fissuring in cartilage that define future onset of OA. In the future, coupling presymptomatic OA detection with emergent clinical therapies could modify the outcome of a disease that costs the United States healthcare system $16.5 billion annually. Furthermore, our technique is broadly applicable to earlier image-based detection of many diseases currently diagnosed at advanced stages today.
Collapse
|
22
|
Meadows KD, Johnson CL, Peloquin JM, Spencer RG, Vresilovic EJ, Elliott DM. Impact of pulse sequence, analysis method, and signal to noise ratio on the accuracy of intervertebral disc T 2 measurement. JOR Spine 2020; 3:e1102. [PMID: 33015575 PMCID: PMC7524248 DOI: 10.1002/jsp2.1102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 05/28/2020] [Accepted: 06/01/2020] [Indexed: 12/17/2022] Open
Abstract
Noninvasive assessments of intervertebral disc health and degeneration are critical for addressing disc degeneration and low back pain. Magnetic resonance imaging (MRI) is exceptionally sensitive to tissue with high water content, and measurement of the MR transverse relaxation time, T 2, has been applied as a quantitative, continuous, and objective measure of disc degeneration that is linked to the water and matrix composition of the disc. However, T 2 measurement is susceptible to inaccuracies due to Rician noise, T 1 contamination, and stimulated echo effects. These error generators can all be controlled for with proper data collection and fitting methods. The objective of this study was to identify sequence parameters to appropriately acquire MR data and to establish curve fitting methods to accurately calculate disc T 2 in the presence of noise by correcting for Rician noise. To do so, we compared T 2 calculated from the typical monoexponential (MONO) fits and noise corrected exponential (NCEXP) fits. We examined how the selected sequence parameters altered the calculated T 2 in silico and in vivo. Typical MONO fits were frequently poor due to Rician noise, and NCEXP fits were more likely to provide accurate T 2 calculations. NCEXP is particularly less biased and less uncertain at low SNR. This study showed that the NCEXP using sequences with data from 20 echoes out to echo times of ~300 ms is the best method for calculating T 2 of discs. By acquiring signal data out to longer echo times and accounting for Rician noise, the curve fitting is more robust in calculating T 2 despite the noise in the data. This is particularly important when considering degenerate discs or AF tissue because the SNR of these regions is lower.
Collapse
Affiliation(s)
- Kyle D Meadows
- Biomedical Engineering University of Delaware Newark Delaware USA
| | - Curtis L Johnson
- Biomedical Engineering University of Delaware Newark Delaware USA
| | - John M Peloquin
- Biomedical Engineering University of Delaware Newark Delaware USA
| | - Richard G Spencer
- National Institute on Aging, National Institutes of Health Baltimore Maryland USA
| | | | - Dawn M Elliott
- Biomedical Engineering University of Delaware Newark Delaware USA
| |
Collapse
|
23
|
Shi B, Huang H. Computational technology for nasal cartilage-related clinical research and application. Int J Oral Sci 2020; 12:21. [PMID: 32719336 PMCID: PMC7385163 DOI: 10.1038/s41368-020-00089-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 07/03/2020] [Accepted: 07/06/2020] [Indexed: 02/05/2023] Open
Abstract
Surgeons need to understand the effects of the nasal cartilage on facial morphology, the function of both soft tissues and hard tissues and nasal function when performing nasal surgery. In nasal cartilage-related surgery, the main goals for clinical research should include clarification of surgical goals, rationalization of surgical methods, precision and personalization of surgical design and preparation and improved convenience of doctor-patient communication. Computational technology has become an effective way to achieve these goals. Advances in three-dimensional (3D) imaging technology will promote nasal cartilage-related applications, including research on computational modelling technology, computational simulation technology, virtual surgery planning and 3D printing technology. These technologies are destined to revolutionize nasal surgery further. In this review, we summarize the advantages, latest findings and application progress of various computational technologies used in clinical nasal cartilage-related work and research. The application prospects of each technique are also discussed.
Collapse
Affiliation(s)
- Bing Shi
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, 610041, Chengdu, China
| | - Hanyao Huang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Oral Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, 610041, Chengdu, China.
| |
Collapse
|
24
|
Martín Noguerol T, Raya JG, Wessell DE, Vilanova JC, Rossi I, Luna A. Functional MRI for evaluation of hyaline cartilage extracelullar matrix, a physiopathological-based approach. Br J Radiol 2019; 92:20190443. [PMID: 31433668 DOI: 10.1259/bjr.20190443] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
MRI of articular cartilage (AC) integrity has potential to become a biomarker for osteoarthritis progression. Traditional MRI sequences evaluate AC morphology, allowing for the measurement of thickness and its change over time. In the last two decades, more advanced, dedicated MRI cartilage sequences have been developed aiming to assess AC matrix composition non-invasively and detect early changes in cartilage not captured on morphological sequences. T2-mapping and T1ρ sequences can be used to estimate the relaxation times of water inside the AC. These sequences have been introduced into clinical protocols and show promising results for cartilage assessment. Extracelullar matrix can also be assessed using diffusion-weighted imaging and diffusion tensor imaging as the movement of water is limited by the presence of extracellular matrix in AC. Specific techniques for glycosaminoglycans (GAG) evaluation, such as delayed gadolinium enhanced MRI of cartilage or Chemical Exchange Saturation Transfer imaging of GAG, as well as sodium imaging have also shown utility in the detection of AC damage. This manuscript provides an educational update on the physical principles behind advanced AC MRI techniques as well as a comprehensive review of the strengths and weaknesses of each approach. Current clinical applications and potential future applications of these techniques are also discussed.
Collapse
Affiliation(s)
| | - Jose G Raya
- Department of Radiology, NYU School of Medicine, NY, USA
| | | | - Joan C Vilanova
- Department of Radiology, Clínica Girona. Institute Diagnostic Imaging (IDI), University of Girona, Girona, Spain
| | | | - Antonio Luna
- MRI unit, Radiology department, Health Time, Jaén, Spain
| |
Collapse
|
25
|
Maas KJ, Avanesov M, Laqmani A, Weinrich J, Sauer M, Kaul MG, Adam G, Regier M, Behzadi C. Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla. PLoS One 2018; 13:e0202698. [PMID: 30133521 PMCID: PMC6105013 DOI: 10.1371/journal.pone.0202698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Accepted: 08/06/2018] [Indexed: 11/30/2022] Open
Abstract
Objective To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. Methods 20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magnetic Resonance Imaging (MRI) of the pelvic region in a supine position. We included sagittal and para-axial T2w sequences centred over the pubic symphysis in order to identify the complete discus interpubicus. For quantitative analysis, a multi-echo Turbo Spin Echo (TSE) sequence (including 12 echo times between 6.4 and 76.8 ms) was acquired and analysed by using an in-house developed quantification plugin tool (qMapIt) extending ImageJ. Two readers in consensus defined three central slices of the pubic symphysis with the greatest length. For each slice, both readers separately placed three regions-of-interest (ROI) covering the whole discus interpubicus. Both readers repeated the ROI placements in identical fashion after a four-week interval on the original MRI images. Statistical analysis included intraclass correlation coefficient (ICC), nonparametric Wilcoxon test, Fisher exact test and mean relaxation time in ms and 95% confidence intervals. Results T2 relaxation time analysis was performed for all 20 participants. In total, a mean relaxation time of all analysed segments for both observers was 48.6 (±6.3 ms), with a mean relaxation time for observer 1 of 48.7 (±6.0 ms) and for observer 2 of 48.5 ms (±6.6ms). The calculated ICC comparing inter- and intrarater reproducibility was excellent in all segments (≥0.75). Conclusion T2 mapping of the discus interpubicus demonstrates good inter- and intrarater repeatability as well as reliability. Mean relaxation times were calculated with 48.6ms in healthy volunteers.
Collapse
Affiliation(s)
- Kai-Jonathan Maas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Maxim Avanesov
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Azien Laqmani
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Julius Weinrich
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Markus Sauer
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael G. Kaul
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Marc Regier
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Cyrus Behzadi
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- * E-mail:
| |
Collapse
|
26
|
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, New Territories, Hong Kong, China
| |
Collapse
|
27
|
Li RK, Ren XP, Yan FH, Qiang JW, Lin HM, Tao Wang, Zhao HF, Chen WB. Liver fibrosis detection and staging: a comparative study of T1ρ MR imaging and 2D real-time shear-wave elastography. Abdom Radiol (NY) 2018; 43:1713-1722. [PMID: 29198003 PMCID: PMC6061497 DOI: 10.1007/s00261-017-1381-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Purpose To compare the results of T1ρ MR imaging and 2D real-time shear-wave elastography (SWE) for liver fibrosis detection and staging. Methods Twenty-nine rabbit models of CCl4-induced liver fibrosis were established and six untreated rabbits served as controls. T1ρ MR imaging and 2D real-time SWE examination were performed at 2, 4, 6, 8, 10, and 12 weeks. T1ρ values and liver stiffness (LS) values were measured. Fibrosis was staged according to the METAVIR scoring system. Correlation test was performed among T1ρ values, LS values, and fibrosis stage. Receiver operating characteristic (ROC) analysis was performed for assessing diagnostic performance of T1ρ and SWE in detection of no fibrosis (F0), substantial fibrosis (≥ F2), severe fibrosis (≥ F3), and cirrhosis (F4). Results There was moderate positive correlation between fibrosis stage and T1ρ values (r = 0.566; 95% CI 0.291–0.754; P < 0.0001), and LS value (r = 0.726; 95% CI 0.521–0.851; P = 0.003). T1ρ values showed moderate positive correlations with LS values [r = 0.693; 95% confidence interval (CI) 0.472–0.832; P < 0.0001]. Areas Under ROC (AUROCs) were 0.861 (95% CI 0.705–0.953) for SWE and 0.856 (95% CI 0.698–0.950) for T1ρ (P = 0.940), 0.906 (95% CI 0.762–0.978) for SWE and 0.849 (95% CI 0.691–0.946) for T1ρ (P = 0.414), 0.870 (95% CI 0.716–0.958) for SWE and 0.799 (95% CI 0.632–0.913) for T1ρ (P = 0.422), and 0.846 (95% CI 0.687–0.944) for SWE and 0.692 (95% CI 0.517–0.835) for T1ρ (P = 0.137), when diagnosing liver fibrosis with ≥ F1, ≥ F2, ≥ F3, and F4, respectively. There was moderate positive correlation between inflammatory activity and T1ρ values (r = 0.520; 95% CI 0.158–0.807; P = 0.013). Conclusion T1ρ imaging has potential for liver fibrosis detection and staging with good diagnostic capability similar to that of ultrasonography elastography.
Collapse
|
28
|
Paul CPL, Smit TH, de Graaf M, Holewijn RM, Bisschop A, van de Ven PM, Mullender MG, Helder MN, Strijkers GJ. Quantitative MRI in early intervertebral disc degeneration: T1rho correlates better than T2 and ADC with biomechanics, histology and matrix content. PLoS One 2018; 13:e0191442. [PMID: 29381716 PMCID: PMC5790235 DOI: 10.1371/journal.pone.0191442] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Accepted: 01/04/2018] [Indexed: 12/13/2022] Open
Abstract
Introduction Low-back pain (LBP) has been correlated to the presence of intervertebral disc (IVD) degeneration on T2-weighted (T2w) MRI. It remains challenging, however, to accurately stage degenerative disc disease (DDD) based on T2w MRI and measurements of IVD height, particularly for early DDD. Several quantitative MRI techniques have been introduced to detect changes in matrix composition signifying early DDD. In this study, we correlated quantitative T2, T1rho and Apparent Diffusion Coefficient (ADC) values to disc mechanical behavior and gold standard early DDD markers in a graded degenerated lumbar IVD caprine model, to assess their potential for early DDD detection. Methods Lumbar caprine IVDs were injected with either 0.25 U/ml or 0.5 U/ml Chondroïtinase ABC (Cabc) to trigger early DDD-like degeneration. Injection with phosphate-buffered saline (PBS) served as control. IVDs were cultured in a bioreactor for 20 days under axial physiological loading. High-resolution 9.4 T MR images were obtained prior to intervention and after culture. Quantitative MR results were correlated to recovery behavior, histological degeneration grading, and the content of glycosaminoglycans (GAGs) and water. Results Cabc-injected IVDs showed aberrancies in biomechanics and loss of GAGs without changes in water-content. All MR sequences detected changes in matrix composition, with T1rho showing largest changes pre-to-post in the nucleus, and significantly more than T2 and ADC. Histologically, degeneration due to Cabc injection was mild. T1rho nucleus values correlated strongest with altered biomechanics, histological degeneration score, and loss of GAGs. Conclusions T2- and T1rho quantitative MR-mapping detected early DDD changes. T1rho nucleus values correlated better than T2 and ADC with biomechanical, histological, and GAG changes. Clinical implementation of quantitative MRI, T1rho particularly, could aid in distinguishing DDD more reliably at an earlier stage in the degenerative process.
Collapse
Affiliation(s)
- Cornelis P L Paul
- Department of Orthopedic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Theodoor H Smit
- Department of Orthopedic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.,Department of Medical Biology, Academic Medical Center (AMC), University of Amsterdam, Amsterdam, The Netherlands
| | - Magda de Graaf
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Roderick M Holewijn
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Arno Bisschop
- Department of Orthopedic Surgery, VU University Medical Center, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - Peter M van de Ven
- Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, The Netherlands
| | - Margriet G Mullender
- Department of Plastic, Reconstructive and Hand Surgery, VU University Medical Center, Amsterdam, The Netherlands
| | - Marco N Helder
- Department of Oral and Maxillofacial Surgery, VU University Medical Center, Amsterdam, The Netherlands
| | - Gustav J Strijkers
- Department of Biomedical Engineering and Physics, Academic Medical Center (AMC), Amsterdam, the Netherlands
| |
Collapse
|
29
|
Wáng YXJ, Chen W, Deng M. How liver pathologies contribute to T1rho contrast require more careful studies. Quant Imaging Med Surg 2017; 7:608-613. [PMID: 29184772 DOI: 10.21037/qims.2017.10.02] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, the Chinese University of Hong Kong, New Territories, Hong Kong SAR, China
| | - Weitian Chen
- Department of Imaging and Interventional Radiology, Faculty of Medicine, the Chinese University of Hong Kong, New Territories, Hong Kong SAR, China
| | - Min Deng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, the Chinese University of Hong Kong, New Territories, Hong Kong SAR, China
| |
Collapse
|
30
|
Kester BS, Carpenter PM, Yu HJ, Nozaki T, Kaneko Y, Yoshioka H, Schwarzkopf R. T1ρ/T2 mapping and histopathology of degenerative cartilage in advanced knee osteoarthritis. World J Orthop 2017; 8:350-356. [PMID: 28473964 PMCID: PMC5396021 DOI: 10.5312/wjo.v8.i4.350] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 12/11/2016] [Accepted: 01/03/2017] [Indexed: 02/06/2023] Open
Abstract
AIM To investigate whether normal thickness cartilage in osteoarthritic knees demonstrate depletion of proteoglycan or collagen content compared to healthy knees.
METHODS Magnetic resonance (MR) images were acquired from 5 subjects scheduled for total knee arthroplasty (TKA) (mean age 70 years) and 20 young healthy control subjects without knee pain (mean age 28.9 years). MR images of T1ρ mapping, T2 mapping, and fat suppressed proton-density weighted sequences were obtained. Following TKA each condyle was divided into 4 parts (distal medial, posterior medial, distal lateral, posterior lateral) for cartilage analysis. Twenty specimens (bone and cartilage blocks) were examined. For each joint, the degree and extent of cartilage destruction was determined using the Osteoarthritis Research Society International cartilage histopathology assessment system. In magnetic resonance imaging (MRI) analysis, 2 readers performed cartilage segmentation for T1ρ/T2 values and cartilage thickness measurement.
RESULTS Eleven areas in MRI including normal or near normal cartilage thickness were selected. The corresponding histopathological sections demonstrated mild to moderate osteoarthritis (OA). There was no significant difference in cartilage thickness in MRI between control and advanced OA samples [medial distal condyle, P = 0.461; medial posterior condyle (MPC), P = 0.352; lateral distal condyle, P = 0.654; lateral posterior condyle, P = 0.550], suggesting arthritic specimens were morphologically similar to normal or early staged degenerative cartilage. Cartilage T2 and T1ρ values from the MPC were significantly higher among the patients with advanced OA (P = 0.043). For remaining condylar samples there was no statistical difference in T2 and T1ρ values between cases and controls but there was a trend towards higher values in advanced OA patients.
CONCLUSION Though cartilage is morphologically normal or near normal, degenerative changes exist in advanced OA patients. These changes can be detected with T2 and T1ρ MRI techniques.
Collapse
|
31
|
Bangerter NK, Taylor MD, Tarbox GJ, Palmer AJ, Park DJ. Quantitative techniques for musculoskeletal MRI at 7 Tesla. Quant Imaging Med Surg 2016; 6:715-730. [PMID: 28090448 DOI: 10.21037/qims.2016.12.12] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Whole-body 7 Tesla MRI scanners have been approved solely for research since they appeared on the market over 10 years ago, but may soon be approved for selected clinical neurological and musculoskeletal applications in both the EU and the United States. There has been considerable research work on musculoskeletal applications at 7 Tesla over the past decade, including techniques for ultra-high resolution morphological imaging, 3D T2 and T2* mapping, ultra-short TE applications, diffusion tensor imaging of cartilage, and several techniques for assessing proteoglycan content in cartilage. Most of this work has been done in the knee or other extremities, due to technical difficulties associated with scanning areas such as the hip and torso at 7 Tesla. In this manuscript, we first provide some technical context for 7 Tesla imaging, including challenges and potential advantages. We then review the major quantitative MRI techniques being applied to musculoskeletal applications on 7 Tesla whole-body systems.
Collapse
Affiliation(s)
- Neal K Bangerter
- Department of Electrical & Computer Engineering, Brigham Young University, Provo, UT, USA;; Department of Radiology, University of Utah, Salt Lake City, UT, USA
| | - Meredith D Taylor
- Department of Electrical & Computer Engineering, Brigham Young University, Provo, UT, USA
| | - Grayson J Tarbox
- Department of Electrical & Computer Engineering, Brigham Young University, Provo, UT, USA
| | - Antony J Palmer
- Department of Orthopaedics, University of Oxford, Oxford, UK
| | - Daniel J Park
- Department of Orthopaedics, University of Oxford, Oxford, UK
| |
Collapse
|
32
|
Hwang D, Kim S, Abeydeera NA, Statum S, Masuda K, Chung CB, Siriwanarangsun P, Bae WC. Quantitative magnetic resonance imaging of the lumbar intervertebral discs. Quant Imaging Med Surg 2016; 6:744-755. [PMID: 28090450 DOI: 10.21037/qims.2016.12.09] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Human lumbar spine is composed of multiple tissue components that serve to provide structural stability and proper nutrition. Conventional magnetic resonance (MR) imaging techniques have been useful for evaluation of IVD, but inadequate at imaging the discovertebral junction and ligamentous tissues due primarily to their short T2 nature. Ultrashort time to echo (UTE) MR techniques acquire sufficient MR signal from these short T2 tissues, thereby allowing direct and quantitative evaluation. This article discusses the anatomy of the lumbar spine, MR techniques available for morphologic and quantitative MR evaluation of long and short T2 tissues of the lumbar spine, considerations for T2 relaxation modeling and fitting, and existing and new techniques for spine image post-processing, focusing on segmentation. This article will be of interest to radiologic and orthopaedic researchers performing lumbar spine imaging.
Collapse
Affiliation(s)
- Dosik Hwang
- Department of Radiology, VA San Diego Healthcare System, San Diego, CA, USA; ; School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | - Sewon Kim
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | - Nirusha A Abeydeera
- Department of Radiology, University of California-San Diego, La Jolla, CA, USA
| | - Sheronda Statum
- Department of Radiology, VA San Diego Healthcare System, San Diego, CA, USA; ; Department of Radiology, University of California-San Diego, La Jolla, CA, USA
| | - Koichi Masuda
- Department of Orthopaedic Surgery, University of California-San Diego, La Jolla, CA, USA
| | - Christine B Chung
- Department of Radiology, VA San Diego Healthcare System, San Diego, CA, USA; ; Department of Radiology, University of California-San Diego, La Jolla, CA, USA
| | - Palanan Siriwanarangsun
- Department of Radiology, University of California-San Diego, La Jolla, CA, USA;; Department of Radiology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Won C Bae
- Department of Radiology, VA San Diego Healthcare System, San Diego, CA, USA; ; Department of Radiology, University of California-San Diego, La Jolla, CA, USA
| |
Collapse
|
33
|
Gong J, Pedoia V, Facchetti L, Link TM, Ma CB, Li X. Bone marrow edema-like lesions (BMELs) are associated with higher T 1ρ and T 2 values of cartilage in anterior cruciate ligament (ACL)-reconstructed knees: a longitudinal study. Quant Imaging Med Surg 2016; 6:661-670. [PMID: 28090444 DOI: 10.21037/qims.2016.12.11] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND To evaluate the longitudinal changes of bone marrow edema-like lesions (BMELs) in patients after anterior cruciate ligament (ACL) reconstruction and to investigate the effect of BMELs on cartilage matrix composition changes measured using MR T1ρ and T2 mapping. METHODS Patients with acute ACL tear were enrolled in a prospective study. MR imaging was performed at baseline (before surgeries) and at 6-month, 1-year and 2-year after ACL reconstruction. MR imaging included sagittal high-resolution, 3D fast spin-echo (CUBE) sequences for BMEL evaluation, and 3D T1ρ mapping and T2 mapping for cartilage assessment. BMELs were assessed using whole-organ magnetic resonance imaging score (WORMS), and the volume of BMELs was measured by a semi-automatic method. Generalized estimating equation (GEE) was used to explore association between BMELs at baseline and cartilage changes during follow-up. RESULTS Fifty four patients were included in the present study and 39 patients had completed 2-year follow-up. BMELs were noted in 42 injured knees (77.8%) with 105 lesions and in 7 contralateral knees (13.0%) with 9 lesions (χ2=45.763, P<0.001) at the baseline. The WORMS and volume of BMELs of the injured knees were 2.36±0.65 and 386.98±382.54 mm3 (r=0.681, P<0.001), respectively. 87 BMELs were found at baseline in 34 patients (87.2%) of the 39 patients who had completed 2 years follow-up. During the follow-up, 18 (20.7%), 12 (13.8%), and 5 (5.7%) baseline lesions were still seen at 6-month, 1-year and 2-year, respectively. The changes of BMELs prevalence regarding bone compartments over time points were statistically significant (χ2=163.660, P<0.001). Except T2 value at 6 months, T1ρ and T2 values of cartilage overlying baseline BMELs in the injured knees were higher than that of anatomically matched cartilage in the contralateral knees at baseline and each follow-up time-point. In the injured knees, GEE analysis showed that baseline BMELs were significantly associated with higher T1ρ and T2 values of cartilage after adjustment of age, gender, body mass index (BMI), effusion and meniscus tear. The association between BMELs and Knee Injury and Osteoarthritis Outcome Scores (KOOS) scores was not statistically significant. CONCLUSIONS BMEL is a common finding in patients with acute ACL injury and resolves rapidly over time after ACL reconstruction. It is often associated with increased T1ρ and T2 values of cartilage. BMEL at baseline is an independent predictor for faster cartilage degeneration during follow-up.
Collapse
Affiliation(s)
- Jingshan Gong
- Department of Radiology, Shenzhen People's Hospital, the Second Clinical Medical College, Jinan University, Shenzhen 518020, China;; Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94107, USA
| | - Valentina Pedoia
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94107, USA
| | - Luca Facchetti
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94107, USA
| | - Thomas M Link
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94107, USA
| | - C Benjamin Ma
- Department of Orthopaedic Surgery, University of California, San Francisco, CA 94107, USA
| | - Xiaojuan Li
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94107, USA
| |
Collapse
|
34
|
Wáng YXJ. Towards consistency for magnetic resonance (MR) relaxometry of lumbar intervertebral discs. Quant Imaging Med Surg 2016; 6:474-477. [PMID: 27709087 DOI: 10.21037/qims.2016.08.04] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Yì-Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| |
Collapse
|
35
|
Abstract
Context: Radiography is widely accepted as the gold standard for diagnosing osteoarthritis (OA), but it has limitations when assessing early stage OA and monitoring progression. While there are improvements in the treatment of OA, the challenge is early recognition. Evidence Acquisition: MEDLINE and PubMed as well as professional orthopaedic and imaging websites were reviewed from 2006 to 2016. Study Design: Clinical review. Level of Evidence: Level 4. Results: Magnetic resonance imaging (MRI) can provide the most comprehensive assessment of joint injury and OA with the advantages of being noninvasive and multiplanar with excellent soft tissue contrast. However, MRI is expensive, time consuming, and not widely used for monitoring OA clinically. Computed tomography (CT) and CT arthrography (CTA) can also be used to evaluate OA, but these are also invasive and require radiation exposure. Ultrasound is particularly useful for evaluation of synovitis but not for progression of OA. Conclusion: MRI, CT, and CTA are available for the diagnosis and monitoring of OA. Improvement in techniques and decrease in cost can allow some of these modalities to be effective methods of detecting early OA.
Collapse
Affiliation(s)
- Qi Li
- West China Hospital, Orthopaedic Department, Sichuan University, Sichuan Province, China
| | - Keiko Amano
- Department of Orthopaedic Surgery, University of California-San Francisco, San Francisco, California
| | - Thomas M Link
- Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, University of California-San Francisco, San Francisco, California
| | - C Benjamin Ma
- Department of Orthopaedic Surgery, University of California-San Francisco, San Francisco, California
| |
Collapse
|
36
|
Koon CM, Zhang X, Chen W, Chu ESH, San Lau CB, Wáng YXJ. Black blood T1rho MR imaging may diagnose early stage liver fibrosis: a proof-of-principle study with rat biliary duct ligation model. Quant Imaging Med Surg 2016; 6:353-363. [PMID: 27709071 DOI: 10.21037/qims.2016.08.11] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND To explore black blood T1rho (T1ρ) liver imaging and investigate the earliest stage when biliary duct ligation (BDL) induced liver fibrosis can be diagnosed. METHODS MR was performed at 3 Tesla. A T1ρ prepared 2D fast spin echo (FSE) sequence with acquisition of four spin lock times (TSLs: 1, 10, 30, and 50 msec) and spin-lock frequency of 500 Hz was applied. Inherent black blood effect of FSE and double inversion recovery (DIR) achieved blood signal suppression, and 3 axial sections per liver were obtained. Male Sprague-Dawley rats were scanned at baseline (n=32), and on day-3 (n=13), day-5 (n=11), day-7 (n=10), day-10 (n=4) respectively after BDL. Hematoxylin-eosin (HE) and picrosirius red staining liver histology was obtained at these time points. RESULTS The physiological liver parenchyma T1ρ was 38.38±1.53 msec (range, 36.05-41.53 msec). Liver T1ρ value elevated progressively after BDL. On day-10 after BDL all experimental animals can be separated from normal liver based on T1ρ measurement with lowest value being 42.82 msec. Day-7 and day-10 liver resembled METAVIR stage-F1/F2 fibrosis, and fibrous area counted for 0.22%±0.13% and 0.38%±0.44% of liver parenchyma area, respectively. CONCLUSIONS This study provides the first proof-of-principle that T1ρ might diagnose early stage liver fibrosis.
Collapse
Affiliation(s)
- Chi-Man Koon
- Institute of Chinese Medicine, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China;; State Key Laboratory of Phytochemistry and Plant Resources in West China, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Xin Zhang
- Institute of Chinese Medicine, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China;; State Key Laboratory of Phytochemistry and Plant Resources in West China, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Weitian Chen
- Department of Imaging and Interventional Radiology, the Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China
| | - Eagle Siu Hong Chu
- Institute of Digestive Disease and Department of Medicine and Therapeutics, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China
| | - Clara Bik San Lau
- Institute of Chinese Medicine, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China;; State Key Laboratory of Phytochemistry and Plant Resources in West China, the Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China
| | - Yì-Xiáng J Wáng
- Department of Imaging and Interventional Radiology, the Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong SAR, China
| |
Collapse
|
37
|
|
38
|
Mok GSP, Zhang D, Chen SZ, Yuan J, Griffith JF, Wang YXJ. Comparison of three approaches for defining nucleus pulposus and annulus fibrosus on sagittal magnetic resonance images of the lumbar spine. J Orthop Translat 2016; 6:34-41. [PMID: 30035081 PMCID: PMC5987025 DOI: 10.1016/j.jot.2016.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2015] [Revised: 02/08/2016] [Accepted: 02/22/2016] [Indexed: 12/14/2022] Open
Abstract
Objective To compare three methods commonly used in the literature to define intervertebral disc nucleus pulposus (NP) and annulus fibrosus (AF) on magnetic resonance (MR) images. Methods Fifty-two patients (26 males and 26 females; age range, 23-76 years) were recruited for this study; they underwent standard T1/T2-weighted MR imaging, and T2 and T1rho mapping acquisitions. The corresponding midsagittal images were analysed and a total of 256 discs were evaluated, using three different region-of-interest (ROI) drawing methods: (1) radiologist-guided manual ROI (M-ROI); (2) five square ROIs where each measured 20% of the midline disc diameter (5-ROI); and (3) seven square ROIs placed horizontally from anterior to posterior (7-ROI) to define NP and AF. The agreement between the three ROI methods was assessed using intraclass correlation coefficient values and Bland-Altman plots. Results Inner AF and NP could not be differentiated on T1/T2-weighted MR imaging, T2 maps, or T1rho maps. The intraclass correlation coefficient values were all > 0.75 when comparing the 5-/7-ROI methods with the M-ROI methods for NP, and 0.167-0.488 for AF when comparing the 7-ROI method with the M-ROI method. The intraclass correlation coefficient values for AF increased to 0.378-0.582 for the M-ROI method compared with the 5-ROI method. Comparable results were obtained with Bland-Altman plots. Conclusion The 5-/7-ROI methods agreed with the M-ROI approach for NP selection, while the agreement with AF was moderate to poor, with the 5-ROI method showing slight advantage over the 7-ROI method. Cautions should be taken to interpret the MR relaxometry findings when 5-/7-ROI methods are used to select AF.
Collapse
Affiliation(s)
- Greta S P Mok
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, University of Macau, Macau Special Administrative Region
| | - Duo Zhang
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, University of Macau, Macau Special Administrative Region
| | - Shu-Zhong Chen
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong Special Administrative Region
| | - Jing Yuan
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong Special Administrative Region
| | - James F Griffith
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong Special Administrative Region
| | - Yi Xiang J Wang
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong Special Administrative Region
| |
Collapse
|