Taira Y, Sakai M, Soeno K, Sawase T. Comparison of four silane primers and an isocyanate primer for bonding of tri-n-butylborane resin to a leucite-reinforced glass ceramic.
J Prosthodont Res 2012. [PMID:
23200531 DOI:
10.1016/j.jpor.2012.09.002]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE
The purpose of the present study was to compare the effectiveness of an isocyanate monomer and four different silane monomers as primer components for bonding a leucite-reinforced glass ceramic (GN-Ceram Block).
METHODS
Four different methyl-methacrylate based primers, each with three different concentrations (1, 4, or 16wt%) of 2-methacryloxyethylisocyanate (MOI), 3-methacryloxypropylmethyldimethoxysilane (MDS), 3-methacryloxypropyltrimethoxysilane (MTS), and 3-acryloxypropyltrimethoxysilane (ATS) were prepared. A commercially available silane primer (ESPE™Sil) was also used as a control. The GN-Ceram Block specimen was ground with silicon carbide paper, rinsed, primed, and then bonded to a resin composite disk using a tri-n-butylborane-initiated self-curing luting agent. After 24-h immersion in water, the shear bond strengths were determined.
RESULTS
The highest level of bond strength was obtained with 4wt% MTS (45.2 MPa) and 4wt% ATS (38.7 MPa), followed by 4wt% MOI (29.8 MPa), ESPE™Sil (28.1 MPa), and 4wt% MDS (27.9 MPa). For each MTS, ATS, MOI, and MDS, the bond strengths for concentrations of 4wt% and 16wt% were not significantly different. No significant differences were found between 4wt% ATS, 4wt% MOI, ESPE™Sil, and 4wt% MDS. The use of any of these primers led to a significant increase in bond strength compared to an unprimed control (13.8 MPa).
CONCLUSIONS
The type and concentration of monomers dissolved in the primer influence the bond strength between a tri-n-butylborane resin and a leucite-reinforced glass ceramic GN-Ceram Block. The effectiveness of MOI was found to be comparable to that of MDS, ATS, and ESPE™Sil, but inferior to that of MTS.
Collapse