1
|
Lei B, Xiong H, Chen K. Comparison of wear and marginal fitness of 3D-printed deciduous molar crowns: An in vitro study. Dent Mater J 2024; 43:227-234. [PMID: 38417862 DOI: 10.4012/dmj.2022-143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
This study aimed to evaluate the wear resistance of primary tooth enamel and 3 kinds of 3D printing materials and to compare the marginal fitness and internal suitability of prefabricated all-ceramic crowns, computer-aided design/manufacturing (CAD/CAM) all-ceramic crowns, and three 3D-printed deciduous molar crowns. Multifunctional friction wear testing machine was used to image the wear surface of the sample and calculate the maximum wear depth and volume loss value of each sample. The internal fit evaluation used the silicon replica method, The four points were measured using scanning electron microscopy (SEM). The obtained data were statistically analyzed using ANOVA and Tukey HSD-test with a fully randomized design (p<0.05). The results showed the wear resistance of E-Dent400 was better than that of PEEK and three different 3D printed materials have good wear resistance compared with the primary tooth enamel. The measured values at M1 and M4 of E-Dent400 were both the smallest.
Collapse
Affiliation(s)
- Bin Lei
- Department of pedodontics, Stomatological Hospital, Southern Medical University
- School of Stomatology, Jinan University
| | - Huacui Xiong
- Department of pedodontics, Stomatological Hospital, Southern Medical University
| | - Ke Chen
- Department of pedodontics, Stomatological Hospital, Southern Medical University
| |
Collapse
|
2
|
Someya T, Kasahara M, Takemoto S, Hattori M. The Wear Behavior of Glass-Ceramic CAD/CAM Blocks against Bovine Enamel. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6839. [PMID: 37959436 PMCID: PMC10649743 DOI: 10.3390/ma16216839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/18/2023] [Accepted: 10/23/2023] [Indexed: 11/15/2023]
Abstract
The wear of enamel and crown restorative materials often occur by occlusion. The purpose of this study was to evaluate the wear volume between glass-ceramics used for CAD/CAM blocks (lithium disilicate: Initial LiSi block (LIS), IPS e.max CAD (IPS), zirconia-reinforced lithium silicate glass-ceramics: Celtra DUO (DUO), VITA Suprinity (VITS) and feldspar-based glass-ceramics: Vitablocs Mark II (MAK)) and bovine tooth enamel using a two-body wear test, the hardness, three-point bending strength, micro-structure and the element components of glass-ceramics. The data were analyzed using a one-way analysis of variance and Tukey's multiple comparison test (α = 0.05). IPS and DUO with relatively large size crystal gain had significantly larger abrader wear volumes. Zirconia-reinforced lithium silicate glass-ceramics (DUO, VITS) caused significantly greater wear volume in antagonist enamel. MAK with scale-shape crystals grains produced distinct scratches after wear tests, both in the material itself and in the enamel. A strong correlation between the mechanical properties (hardness, three-point bending strength) and wear volume could not be confirmed. The type of glass-ceramic, size, and shape of the crystal grains affected the wear behavior of the glass-ceramics for CAD/CAM blocks. Therefore, dentists should consider that wear behavior varies with crystal structure, size, and shape in glass-ceramics for CAD/CAM blocks.
Collapse
Affiliation(s)
- Tomoko Someya
- Department of Dental Materials Science, Tokyo Dental College, 2-9-18 Kandamisaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan; (M.K.); (M.H.)
| | - Masaaki Kasahara
- Department of Dental Materials Science, Tokyo Dental College, 2-9-18 Kandamisaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan; (M.K.); (M.H.)
| | - Shinji Takemoto
- Department of Biomedical Engineering, Iwate Medical University, 1-1-1 Idaidori, Yahaba-cho, Iwate, Shiwa-gun 028-3694, Japan;
| | - Masayuki Hattori
- Department of Dental Materials Science, Tokyo Dental College, 2-9-18 Kandamisaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan; (M.K.); (M.H.)
| |
Collapse
|
3
|
Jin C, Deng J, Pan P, Xiong Y, Zhu L, Gao S. Comparative study on the impact-sliding wear behaviour of CAD/CAM resin-ceramic materials and tooth enamel. Dent Mater 2023; 39:25-40. [PMID: 36456379 DOI: 10.1016/j.dental.2022.11.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 10/05/2022] [Accepted: 11/11/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To compare the impact-sliding wear of different CAD/CAM resin-ceramic materials and tooth enamel, and explore the corresponding wear damage mechanism. METHODS Human tooth enamel (EN), Vita ENAMIC (Vita, VE), Lava Ultimate (3 M, LU), and GC CERASMART (GC, CS) were used in this study. The hardness, elastic modulus, and roughness values of the samples were measured. Further, impact-sliding wear tests were performed in a ball-on-flat configuration with spherical zirconia antagonists and the coefficients of friction (CoF) were recorded simultaneously. Additionally, a white light interferometer was used to determine the volume losses and scanning electron microscopy was used to observe the wear morphology of the wear scars and the damage feature in the vertical sections to clarify the damage mechanism during the impact-sliding wear test. RESULTS EN exhibited the highest elastic modulus and CoF, followed by VE, LU, and CS. The hardness and roughness of EN and VE were similar and were higher than those of LU and CS. Throughout the wear tests, VE exhibited the highest volume loss, whereas CS exhibited the lowest. The wear damage characteristics of VE were similar to those of EN, displaying brittle fractures of inorganic substances and plastic deformation of organic substances in the impact part, exhibiting plough marks in the sliding parts. In the case of LU and CS, the entire wear areas displayed plastic deformation of the resin matrix, exfoliation of the filler particles, and plough marks. SIGNIFICANCE Enamel and polymer-infiltrated ceramic network materials exhibit similar wear damage modes. Additionally, the high-density nanocomposite resin material is the most resistant to impact-sliding wear from a tribological perspective.
Collapse
Affiliation(s)
- Chunxiao Jin
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Jiuhong Deng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Peiyue Pan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Yuhuan Xiong
- Department of Stomatology, The First People's Hospital of Longquanyi District, Chengdu, Sichuan 610100, China
| | - Liqing Zhu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Shanshan Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China.
| |
Collapse
|
4
|
Chen F, Sun L, Luo H, Yu P, Lin J. Influence of filler types on wear and surface hardness of composite resin restorations. J Appl Biomater Funct Mater 2023; 21:22808000231193524. [PMID: 37776080 DOI: 10.1177/22808000231193524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2023] Open
Abstract
OBJECTIVE Wear and surface hardness of resin composites are of relevance from the clinical standpoint. With the incorporation of novel filler system, more studies need to be performed to investigate newly marketed resin composites. The objective of this study was to investigate the abrasive wear and surface hardness of dental restorative with different filler types. METHODS Nanohybrid filled Harmonize (HM) and Tetric N-Ceram (TNC), microhybrid filled Filtek Z250 (Z250), nanofilled Filtek Z350 (Z350) were included in the study. Twelve cylindrical resin composites specimens with 10 mm in diameter and 6 mm in thickness were prepared for abrasive wear test. Eight hundred cycles under 17 kg load were conducted for final wear by CW3-1 wear machine. The specimen was cleaned with an ultrasonic unit for 3 min followed with drying procedure. After measurement of weight loss and the density of specimens, the specimens were kept for measurement of surface hardness. Surface hardness was measured using a micro-hardness tester with a Vickers diamond indenter after polishing. Three specimens of each material were observed by scanning electron microscopy (SEM) after the abrasion to evaluate the morphology of the surface. Data were analyzed using one-way analysis of variance (ANOVA), followed by Tukey HSD test (α = .05). RESULTS Z250 performed the least volume wear loss (41.1 ± 2.1 mm3), as well as the hardest value (102.7 ± 2.9 HV). There was no significant difference with the volume wear loss (p = 1.000) and surface hardness (p = 0.874) of HM and TNC. SEM images of nanohybrid filled HM and TNC represented smoother surface compared with other types of resin composites. CONCLUSIONS Microhybrid Z250 showed the highest wear resistance and surface hardness, nanofilled and nanohybrid resin composites may still face the insufficient of wear and surface hardness quality.
Collapse
Affiliation(s)
- Fei Chen
- Department of Stomatology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Lijuan Sun
- Department of Stomatology, Ordos Central Hospital & Ordos School of Clinical Medicine, Inner Mongolia Medical University, Inner Mongolia, China
| | - Hao Luo
- Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, China
| | - Peng Yu
- Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, China
| | - Jiang Lin
- Department of Stomatology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
5
|
Hatanaka A, Sawada T, Sen K, Saito T, Sasaki K, Someya T, Hattori M, Takemoto S. Wear Behavior between Aesthetic Restorative Materials and Bovine Tooth Enamel. MATERIALS 2022; 15:ma15155234. [PMID: 35955169 PMCID: PMC9369959 DOI: 10.3390/ma15155234] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/14/2022] [Accepted: 07/25/2022] [Indexed: 02/04/2023]
Abstract
Tooth enamel wear occurs because of daily mastication and occlusion. This study investigated the wear behavior of bovine teeth against aesthetic restorative materials in vitro. Abrader specimens were fabricated using four tooth-colored restorative materials (zirconia, lithium disilicate glass ceramic, dental porcelain, and resin composite), with bovine tooth enamel as a control. Flattened bovine tooth enamel was used as the substrate specimen. These materials were characterized by Vickers hardness tests and surface roughness measurements. Two-body wear tests between the abrader and substrate specimens were performed, and the worn topographies were evaluated using a contour-measuring instrument and 3D laser microscope. The restorative materials and bovine tooth enamel had similar surface roughness but different hardness and wear behaviors. Bovine teeth showed the largest wear in tooth–tooth contact as the abrader and substrate specimens. Compared to bovine teeth, zirconia, lithium disilicate glass ceramic, and dental porcelain showed greater hardness and less wear on their surfaces, and less substrate wear of the opposite tooth enamel. The lowest hardness resin composite showed intermediate wear on its surface, resulting in the lowest substrate wear. Accordingly, dentists should pay attention to the selection of restorative materials to reconstruct their morphologies owing to different wear behaviors.
Collapse
Affiliation(s)
- Akihiko Hatanaka
- Department of Biomedical Engineering, Iwate Medical University, 1-1-1 Idaidori, Yahaba-cho, Shiwa-gun 028-3694, Iwate, Japan; (A.H.); (K.S.); (S.T.)
| | - Tomofumi Sawada
- Department of Biomedical Engineering, Iwate Medical University, 1-1-1 Idaidori, Yahaba-cho, Shiwa-gun 028-3694, Iwate, Japan; (A.H.); (K.S.); (S.T.)
- Correspondence: ; Tel.: +81-19-651-5110
| | - Kazuyo Sen
- School of Dentistry, Iwate Medical University, 19-1 Uchimaru, Morioka-shi 020-8505, Iwate, Japan; (K.S.); (T.S.)
| | - Takahiro Saito
- School of Dentistry, Iwate Medical University, 19-1 Uchimaru, Morioka-shi 020-8505, Iwate, Japan; (K.S.); (T.S.)
| | - Kaori Sasaki
- Department of Biomedical Engineering, Iwate Medical University, 1-1-1 Idaidori, Yahaba-cho, Shiwa-gun 028-3694, Iwate, Japan; (A.H.); (K.S.); (S.T.)
| | - Tomoko Someya
- Department of Dental Materials Science, Tokyo Dental College, 2-9-18 Kandamisaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan; (T.S.); (M.H.)
| | - Masayuki Hattori
- Department of Dental Materials Science, Tokyo Dental College, 2-9-18 Kandamisaki-cho, Chiyoda-ku, Tokyo 101-0061, Japan; (T.S.); (M.H.)
| | - Shinji Takemoto
- Department of Biomedical Engineering, Iwate Medical University, 1-1-1 Idaidori, Yahaba-cho, Shiwa-gun 028-3694, Iwate, Japan; (A.H.); (K.S.); (S.T.)
| |
Collapse
|
6
|
Baldi A, Carossa M, Comba A, Alovisi M, Femiano F, Pasqualini D, Berutti E, Scotti N. Wear Behaviour of Polymer-Infiltrated Network Ceramics, Lithium Disilicate and Cubic Zirconia against Enamel in a Bruxism-Simulated Scenario. Biomedicines 2022; 10:biomedicines10071682. [PMID: 35884986 PMCID: PMC9313215 DOI: 10.3390/biomedicines10071682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 07/08/2022] [Accepted: 07/11/2022] [Indexed: 11/16/2022] Open
Abstract
The present study aimed to evaluate the wear rate of polymer-infiltrated network composites and ceramics against enamel in a bruxism-simulated scenario. Ninety-six (n = 96) molars were divided into six groups (n = 16) according to their occlusal material: group 1—a polymer-infiltrated network ceramic (PINC); group 2—a second polymer-infiltrated network ceramic (PINC2); group 3—nanohybrid resin-based composite (CO); group 4—cubic zirconia (ZR); group 5—lithium disilicate (LS); and group 6—sound enamel (EN). A laser scanner was used to digitalize all of the occlusal surfaces before and after a fatigue test, which was conducted with a chewing simulator set at 80 N and semicircular movement in order to simulate bruxist movement and loads. Statistical analysis of volume loss was performed with a one-way ANOVA and post hoc Bonferroni test. ZR had significantly inferior wear to PINC (p ≤ 0.01) and CO (p = 0.04). LS wore the antagonist enamel significantly more than PINC, CO, PINC2 and EN (p ≤ 0.01). On the other hand, ZR wore the antagonist enamel significantly more than CO (p ≤ 0.01) and PINC2 (p = 0.05). In conclusion, PINCs better preserved antagonist enamel at the expense of a higher wear of their own. LS causes significantly higher enamel wear compared with PINCs. ZR caused significantly higher enamel wear compared with CO and PINC2, but it was wear-resistant.
Collapse
Affiliation(s)
- Andrea Baldi
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Massimo Carossa
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
- Correspondence:
| | - Allegra Comba
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Mario Alovisi
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Felice Femiano
- Restorative Dentistry, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Study of Campania, “Luigi Vanvitelli”, Via De Crecchio 6, 83138 Naples, Italy;
| | - Damiano Pasqualini
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Elio Berutti
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Nicola Scotti
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| |
Collapse
|
7
|
Current status and perspective of CAD/CAM-produced resin composite crowns: a review of clinical effectiveness. JAPANESE DENTAL SCIENCE REVIEW 2020; 56:184-189. [PMID: 33299502 PMCID: PMC7704397 DOI: 10.1016/j.jdsr.2020.10.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 09/25/2020] [Accepted: 10/09/2020] [Indexed: 11/20/2022] Open
Abstract
The purpose of the present review was to survey the available literature on computer-aided design/computer-aided manufacturing (CAD/CAM)-produced resin composite materials to provide clinicians with a current overview of the key components necessary for daily clinical use. An electronic search was conducted in the PubMed database. Peer-reviewed articles in English language on the use of resin composites in CAD/CAM dental crowns were included. A total of 122 full-text articles were identified, 15 of which were selected during the initial review. Two additional articles were also discovered through a manual search, to obtain a final total of 17 articles included in the present review. Of these, 16 were to in vitro studies, and one was an in vivo study. Findings from the in vitro studies indicate that resin composite block materials for CAD/CAM applications demonstrate excellent physical properties and are appropriate for the clinical restoration of premolars and molars. However, the in vivo study reported a low 3-year success rate, but high survival rate for resin composite CAD/CAM crowns placed in the premolar region. The key to ensuring the successful prognosis of a resin composite CAD/CAM crown is to ensure that all steps—such as proper case selection, abutment tooth preparation, occlusal adjustment, and bonding—are accurately performed.
Collapse
|