1
|
Mittal R, Attri S, Batra P, Sonar S, Sharma K, Raghavan S. Comparison of orthodontic space closure using micro-osteoperforation and passive self-ligating appliances or conventional fixed appliances. Angle Orthod 2020; 90:634-639. [PMID: 33378478 PMCID: PMC8032271 DOI: 10.2319/111119-712.1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 02/01/2020] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVES To examine the effect of micro-osteoperforation (MOP) on the space closure rate using passive self-ligating or conventional brackets. MATERIALS AND METHODS This was a two-arm parallel randomized controlled trial undertaken at the outpatient department of a dental college. There were 60 participants (30 women and 30 men) who fulfilled the inclusion criteria. Both the study and control groups were subjected to MOPs throughout the period of space closure. MOPs were repeated every 28 days. The experimental group (mean age 19.5 ± 1.66 years) was bonded with passive self-ligating brackets while the control group (mean age 19.9 ± 1.13 years) was bonded with conventional brackets. Both groups were examined and compared for rate of space closure. An evaluation was conducted for both groups until the entire extraction space was closed and confirmed by evaluation of a tight contact between the canine and the second premolar using a piece of dental floss. RESULTS Before the initiation of retraction, all initial criteria were similar between the two groups (P > .05). No difference was observed between the two groups in the rate of space closure (P > .05). CONCLUSIONS MOP in conjunction with passive self-ligation does not increase the rate of orthodontic space closure when compared with MOP used with conventional brackets.
Collapse
|
2
|
Moyano J, Mases L, Izeta T, Flores T, Fernández-Bozal J, Gil J, Puigdollers A. "In Vitro" Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets. MATERIALS (BASEL, SWITZERLAND) 2019; 12:ma12203279. [PMID: 31600912 PMCID: PMC6829865 DOI: 10.3390/ma12203279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 09/28/2019] [Accepted: 09/30/2019] [Indexed: 06/10/2023]
Abstract
Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know the variables that affect arch displacement in CL and SL brackets-active (ASL) and passive (PSL)-and analyze if static friction values are affected by bracket design, arch wire section, kind of ligature, and use of a friction reducer agent (FRA) in a wet state. Larger values of static friction were found in CL with metallic ligature (ML) (8.01 ± 1.08 N/mm) and elastic ligature (EL) (6.96 ± 0.48 N/mm). Lower values were found in PSL brackets combined with FRA (0.58 ± 0.21 N/mm). The study was carried out using different stereographical models of a maxillary upper right quadrant with canine, first and second premolar, and first molar bonded brackets. A section of 25 mm of 0.019 × 0.025" stainless steel arch with a rectangular section (SS) and hybrid section (HY) was inserted into the different bracket models. Static friction values were collected using a universal test machine in wet conditions and testing the effect of a friction reducer agent (FRA). To assure the reliability of the study, different wire combinations were repeated after two weeks by the same operator and a linear analysis of regression was done. Each bracket model analysis-with the different wires, use of the FRA, and comparison among brackets in similar conditions-was done using an ANOVA test with a confidence interval of 95% and comparative Post-Hoc tests (LSD). In this in vitro simulation we found higher static friction values in CL compared to ASL and PSL. In PSL, lower values were achieved. CL brackets using ML showed the highest static friction values with a great variability. In this setting, the use of HY wires did not reduce static friction values in ASL and PSL, while in CL brackets with EL friction the values were reduced significantly. An FRA combined with ASL reduced significantly static friction values but not with PSL. In the case of CL, the FRA effect was higher with SS and better than with HY wires. ML values were similar to ASL static friction. The direct extrapolation of the results might be inaccurate, since all these findings should be tested clinically to be validated.
Collapse
Affiliation(s)
- Javier Moyano
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| | - Laia Mases
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| | | | - Teresa Flores
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| | - Javier Fernández-Bozal
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| | - Javier Gil
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| | - Andreu Puigdollers
- Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain.
| |
Collapse
|