Christensen JW, Jensen LT, Søndergaard SB, Broholm R, Haarmark C, Krakauer M, Bennedbæk FN, Zerahn B, Trolle W, Hahn CH, Kristensen B. Locating hyperfunctioning parathyroid glands using
11C-Choline PET/CT: an inter- and intra-observer variation study.
Eur J Hybrid Imaging 2021;
5:13. [PMID:
34227025 PMCID:
PMC8257818 DOI:
10.1186/s41824-021-00108-z]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 06/09/2021] [Indexed: 11/29/2022] Open
Abstract
Background
Use of 11C-Choline PET/CT is gaining ground in detecting hyperfunctioning parathyroid glands in primary hyperparathyroidism. The purpose of this study was to evaluate the robustness of 11C-Choline PET/CT by assessing intra- and inter-observer agreement to determine whether the method was reader sensitive and therefore should only be performed at highly specialised sites with a high number of cases.
PET/CT images of 40 patients diagnosed with primary hyperparathyroidism were anonymised and evaluated three times by three readers: an expert reader and two non-experts (non-experts were experienced in PET/CT imaging, but not in 11C-Choline PET/CT in the setting of primary hyperparathyroidism). Number of hyperfunctioning parathyroid glands, location relative to the thyroid gland and confidence of each assessment (low, moderate or high) were noted, and intra- and inter-observer agreement calculated using Fleiss’ kappa method. Sensitivities and specificities of the non-experts were calculated using the expert reader as gold standard.
Results
Intra-observer agreement was ‘good’ to ‘near perfect’ for all readers. Inter-observer agreement was good between non-experts and the expert, with kappa values ≥ 0.74. Sensitivities between non-experts and the expert were high, > 81%, when assessing which side and 75% when assessing thyroid quadrant. All specificities were > 94%. Reader certainties were ‘high’ in > 80% of cases for the expert and > 70% and > 65%, respectively for the two non-experts.
Conclusion
11C-Choline PET/CT is not reader sensitive for the localisation of hyperfunctioning parathyroid glands and may therefore be safely implemented at sites that have a moderate number of cases. Access to a cyclotron laboratory is, however, a necessity for the production of 11C-Choline.
The study was conducted in accordance with the Helsinki 2 declaration and The International Council for Harmonisation Guideline for Good Clinical Practice (ICH_GCP) clinical trial, approved by the Research Ethics Committee of the Capital Region of Denmark (Journal-nr.:H-18012490, date of approval: 18 June 2018) and the Danish Medicines Agency (EudraCT no. 2018-000726-63, date of approval: 6 June 2018). The GCP unit in Eastern Denmark has carried out regular monitoring of the trial according to GCP (ID: 2018-1050).
Supplementary Information
The online version contains supplementary material available at 10.1186/s41824-021-00108-z.
Collapse