1
|
Shi X, Tian D, Ye X, Wu Q, Pan Y, Yang Z, Fan D. Is water exchange superior to water immersion in detecting adenomas during colonoscopies? Results from a Bayesian network meta-analysis. Oncotarget 2018; 9:30679-30693. [PMID: 30093978 PMCID: PMC6078142 DOI: 10.18632/oncotarget.25504] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 05/08/2018] [Indexed: 12/13/2022] Open
Abstract
AIM Water-assisted colonoscopy (water exchange [WE] and water immersion [WI]) has been shown to improve the adenoma detection rate. However, few studies have compared these two methods head-to-head. Thus, we conducted a network meta-analysis to integrate both direct and indirect evidence comparing the effectiveness of these two procedures. METHOD We searched PubMed, Web of Science, and the Cochrane Central Register of Controlled Trials for original papers and abstracts published up to March 2018. Randomized controlled trials (RCTs) reporting data in accordance with the eligibility criteria were included in this study. We performed a Bayesian random effects network meta-analysis with mixed comparisons. RESULTS Twenty-nine studies (n = 11464 patients) including 6 direct and 23 indirect comparisons were included in this network meta-analysis. There was a statistically significant difference in the efficacy of adenoma detection when WE was compared with WI (risk ratio [RR]: 1.2, 95% credible interval [CrI]: 1.1-1.3), air insufflation (AI; RR: 1.3, 95% CrI: 1.1-1.4), and carbon dioxide (CO2) insufflation (RR: 1.2, 95% CrI: 1.1-1.5). The different methods were ranked in order from the most to least effective in adenoma detection as follows: WE, WI, AI, and CO2. Moreover, although there were no significant differences in pain scores, willingness to repeat, caecal intubation rate, or total procedure time between WI and WE colonoscopy, WE required a longer caecal intubation time than WI. CONCLUSION This network meta-analysis supposes that WE may be superior to WI in detecting adenomas during colonoscopies without affecting other technical features or patient acceptance.
Collapse
Affiliation(s)
- Xin Shi
- State Key Laboratory of Cancer Biology, National Clinical Research Center for Digestive Diseases and Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
| | - Dan Tian
- Office of Educational Administration, Fourth Military Medical University, Xi’an, China
| | - Xiaofei Ye
- Department of Health Statistics, Second Military Medical University, Shanghai, China
| | - Qiong Wu
- State Key Laboratory of Cancer Biology, National Clinical Research Center for Digestive Diseases and Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
| | - Yanglin Pan
- State Key Laboratory of Cancer Biology, National Clinical Research Center for Digestive Diseases and Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
| | - Zhiping Yang
- State Key Laboratory of Cancer Biology, National Clinical Research Center for Digestive Diseases and Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
| | - Daiming Fan
- State Key Laboratory of Cancer Biology, National Clinical Research Center for Digestive Diseases and Xijing Hospital of Digestive Diseases, Fourth Military Medical University, Xi’an, China
| |
Collapse
|
2
|
Bayupurnama P, Ratnasari N, Indrarti F, Triwikatmani C, Maduseno S, Nurdjanah S, Leung FW. Endoscope-connected water pump with high flow rates improves the unsedated colonoscopy performance by water immersion method. Clin Exp Gastroenterol 2018; 11:13-18. [PMID: 29391819 PMCID: PMC5769563 DOI: 10.2147/ceg.s152669] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES The aim of this study was to determine if different water pump flow rates influence the insertion time of water immersion method in unsedated patients. We tested the hypothesis that high flow rate (HFR) is more effective than low flow rate (LFR) in facilitating insertion. Clinical registration number: NCT01869296. METHODS Consecutive symptomatic patients without prior abdominal surgery were consented and enrolled. They were randomized to an HFR (10.4 mL/s) or LFR (1.7 mL/s) group. The patients were not informed about the flow rate of the water pump (single blinded). Patients underwent unsedated colonoscopy examination with standard colonoscope. Demographic and procedural parameters were recorded. Data were analyzed with Student's t-test or Chi-square test as appropriate. RESULTS A total of 132 patients (66 in HFR and 66 in LFR group) were recruited. The HFR group showed significantly shorter cecal intubation time (12.5±6.2 min in HFR vs 16.3±7.3 min in LFR, p=0.004), shorter time to pass rectosigmoid (3.6±2.2 min in HFR vs 6.2±4.6 min in LFR, p<0.001), and lower pain score (4.2±2.8 in HFR vs 5.3±2.6 in LFR, p=0.024). The cecal intubation rate was not significantly different (87.9% in HFR vs 80.3% in LFR, p=0.34), and 29 (14 in HFR and 15 in LFR) patients with signs of colon redundancy were successfully intubated to the cecum after repeated loop reduction and position changes. CONCLUSION Compared to LFR, HFR of the water infusion pump significantly reduced colonoscopy insertion time and pain score in unsedated patients. Significantly shorter time to pass the rectosigmoid appeared to play a contributory role.
Collapse
Affiliation(s)
- Putut Bayupurnama
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Neneng Ratnasari
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Fahmi Indrarti
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Catharina Triwikatmani
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Sutanto Maduseno
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Siti Nurdjanah
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, Sardjito General Hospital, Gadjah Mada University, Yogyakarta, Indonesia
| | - Felix W Leung
- Sepulveda Ambulatory Care Center, Veterans Affairs Greater Los Angeles Healthcare System and David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|
3
|
Franco DL, Leighton JA, Gurudu SR. Approach to Incomplete Colonoscopy: New Techniques and Technologies. Gastroenterol Hepatol (N Y) 2017; 13:476-483. [PMID: 28867979 PMCID: PMC5572961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Colonoscopy is the most widely used screening modality for the detection and removal of colon polyps and for the prevention of colorectal cancer. To identify all colon lesions and reduce the risk of colorectal cancer, it is important to perform a complete colonoscopy. The success of screening colonoscopy depends upon several parameters, including bowel preparation and adenoma detection rate. Incomplete colonoscopy rates vary from 4% to 25% and are associated with higher rates of interval proximal colon cancer. This article reviews the potential causes of and preventive measures for incomplete colonoscopy, as well as techniques and technologies that may improve the rate of complete colonoscopy.
Collapse
Affiliation(s)
- Diana L Franco
- Dr Franco is a gastroenterology fellow, Dr Leighton is a professor of medicine, and Dr Gurudu is an associate professor of medicine in the Division of Gastroenterology at the Mayo Clinic Arizona in Scottsdale, Arizona
| | - Jonathan A Leighton
- Dr Franco is a gastroenterology fellow, Dr Leighton is a professor of medicine, and Dr Gurudu is an associate professor of medicine in the Division of Gastroenterology at the Mayo Clinic Arizona in Scottsdale, Arizona
| | - Suryakanth R Gurudu
- Dr Franco is a gastroenterology fellow, Dr Leighton is a professor of medicine, and Dr Gurudu is an associate professor of medicine in the Division of Gastroenterology at the Mayo Clinic Arizona in Scottsdale, Arizona
| |
Collapse
|
4
|
Kim HG. Painless Colonoscopy: Available Techniques and Instruments. Clin Endosc 2016; 49:444-448. [PMID: 27744665 PMCID: PMC5066405 DOI: 10.5946/ce.2016.132] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Revised: 09/19/2016] [Accepted: 09/19/2016] [Indexed: 12/21/2022] Open
Abstract
During colonoscopy, air insufflation to distend the lumen and facilitate careful inspection and scope insertion can induce pain and cause discomfort. Carbon dioxide (CO2) insufflation can decrease abdominal pain and discomfort during and after colonoscopy. The advantage of CO2 insufflation is the rapid absorption of the gas across the intestine. Another painless option is water-assisted colonoscopy. Two methods for water-assisted colonoscopy are available: water immersion and water exchange. In a recent direct comparison, the water exchange method was superior to water immersion, CO2 insufflation, and air insufflation with respect to pain during colonoscopy, although it still had the disadvantage of being a time-consuming procedure. Cap-assisted colonoscopy is a simple technique involving the use of a small transparent cap attached to the tip of the scope. Three studies showed an advantage of this technique in terms of reduced patient discomfort compared with the conventional method. Three robotic colonoscopy systems (Endotics System [Era Endoscopy], NeoGuide [NeoGuide Systems Inc.], and Invendoscope [Invendo Medical]) have been introduced to evaluate pain reduction during colonoscopy, but none has been widely adopted and used in practice. In this review, clinical trials of several techniques and new devices for painless colonoscopy are described and summarized.
Collapse
Affiliation(s)
- Hyun Gun Kim
- Institute for Digestive Research, Soon Chun Hyang University College of Medicine, Seoul, Korea
| |
Collapse
|
5
|
Sugimoto S, Mizukami T. Diagnostic and therapeutic applications of water-immersion colonoscopy. World J Gastroenterol 2015; 21:6451-6459. [PMID: 26074684 PMCID: PMC4458756 DOI: 10.3748/wjg.v21.i21.6451] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 03/15/2015] [Accepted: 04/28/2015] [Indexed: 02/06/2023] Open
Abstract
Colonoscopy techniques combining or replacing air insufflation with water infusion are becoming increasingly popular. They were originally designed to reduce colonic spasms, facilitate cecal intubation, and lower patient discomfort and the need for sedation. These maneuvers straighten the rectosigmoid colon and enable the colonoscope to be inserted deeply without causing looping of the colon. Water-immersion colonoscopy minimizes colonic distension and improves visibility by introducing a small amount of water. In addition, since pain during colonoscopy indicates risk of bowel perforation and sedation masks this important warning, this method has the potential to be the favored insertion technique because it promotes patient safety without sedation. Recently, this water-immersion method has not only been used for colonoscope insertion, but has also been applied to therapy for sigmoid volvulus, removal of lesions, lower gastrointestinal bleeding, and therapeutic diagnosis of abnormal bowel morphology and irritable bowel syndrome. Although a larger sample size and prospective head-to-head-designed studies will be needed, this review focuses on the usefulness of water-immersion colonoscopy for diagnostic and therapeutic applications.
Collapse
|
6
|
Hsieh YH, Leung FW. Response to Feuerstein. Am J Gastroenterol 2015; 110:475-476. [PMID: 25743719 DOI: 10.1038/ajg.2015.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Yu-Hsi Hsieh
- 1] Division of Gastroenterology, Department of Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan [2] Tzu Chi University, School of Medicine, Hualien, Taiwan
| | - Felix W Leung
- 1] Sepulveda Ambulatory Care Center, Veterans Affairs Greater Los Angeles Healthcare System, North Hill, California, USA [2] David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| |
Collapse
|
7
|
Dik VK, Moons LMG, Siersema PD. Endoscopic innovations to increase the adenoma detection rate during colonoscopy. World J Gastroenterol 2014; 20:2200-2211. [PMID: 24605019 PMCID: PMC3942825 DOI: 10.3748/wjg.v20.i9.2200] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Revised: 12/06/2013] [Accepted: 01/20/2014] [Indexed: 02/06/2023] Open
Abstract
Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible.
Collapse
|
8
|
Water infusion versus air insufflation for colonoscopy: a meta-analysis of randomized controlled trials. Tech Coloproctol 2013; 17:487-96. [PMID: 23652813 DOI: 10.1007/s10151-013-1023-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2012] [Accepted: 04/18/2013] [Indexed: 02/06/2023]
Abstract
BACKGROUND The aim of this meta-analysis was to determine whether water infusion colonoscopy (WIC) is a more effective diagnostic tool than standard air insufflation colonoscopy (AIC). METHODS All articles pertinent to a comparison of water-related methods and air insufflation to facilitate insertion of the colonoscope were retrieved from PubMed, Web of Science, Embase, and Cochrane databases. Pooling results were derived by using the Review Manager Software. Outcomes were assessed using the weighted mean difference (MD) with 95 % confidence intervals (CI) for continuous variables and the odds ratios (OR) with 95 % CI for dichotomous variables. RESULTS Eighteen studies involving 2,797 patients were included. WIC was associated with a significantly higher cecal intubation rate than AIC (OR = 1.90; 95 % CI 1.21-2.99; p = 0.005). The intubation time was similar for the two types of colonoscopy, but in WIC there was a significantly lower visual analog scale score for abdominal pain than in AIC (MD = -1.30; 95 % CI -2.03 to -0.58; p < 0.001) without sacrificing the polyp detection rate (OR = 1.17; 95 % CI 0.78-1.77; p = 0.44). Statistically, the patient's willingness to repeat colonoscopy was significantly greater for WIC than for AIC (OR = 1.74; 95 % CI 1.14-2.67; p < 0.01). Furthermore, in the subgroup for trainees, the WIC group achieved a higher cecal intubation rate (OR = 1.83; 95 % CI 1.15-2.93; p = 0.01) and a shorter intubation time (MD = -1.72 min; 95 % CI -3.34 to -0.11; p = 0.04) than the AIC group. CONCLUSIONS In contrast to AIC, WIC improved cecal intubation, alleviated abdominal pain, and increased patients' willingness to repeat the procedure.
Collapse
|
9
|
Fischer LS, Lumsden A, Leung FW. Water exchange method for colonoscopy: learning curve of an experienced colonoscopist in a U.S. community practice setting. JOURNAL OF INTERVENTIONAL GASTROENTEROLOGY 2012; 2:128-132. [PMID: 23805393 DOI: 10.4161/jig.23734] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2012] [Revised: 06/15/2012] [Accepted: 06/05/2012] [Indexed: 01/04/2023]
Abstract
BACKGROUND Water exchange colonoscopy has been reported to reduce examination discomfort and to provide salvage cleansing in unsedated or minimally sedated patients. The prolonged insertion time and perceived difficulty of insertion associated with water exchange have been cited as a barrier to its widespread use. AIM To assess the feasibility of learning and using the water exchange method of colonoscopy in a U.S. community practice setting. SETTING Quality improvement program in nonacademic community endoscopy centers. SUBJECTS Patients undergoing sedated diagnostic, surveillance, or screening colonoscopy. METHODS After direct coaching by a knowledgeable trainer, an experienced colonoscopist initiated colonoscopy using the water method. Whenever >5 min elapsed without advancing the colonoscope, conversion to air insufflation was made to ensure timely completion of the examination. PRIMARY OUTCOME Water Method Intention-to-treat (ITT) cecal intubation rate (CIR). RESULTS Female patients had a significantly higher rate of past abdominal surgery and a significantly lower ITTCIR. The ITTCIR showed a progressive increase over time in both males and females to 85-90%. Mean insertion time was maintained at 9 to 10 min. The overall CIR was 99%. CONCLUSION Use of water exchange did not preclude cecal intubation upon conversion to usual air insufflation in sedated patients examined by an experienced colonoscopist. With practice ITTCIR increased over time in both male and female patients. Larger volumes of water exchanged were associated with higher ITTCIR and better quality scores of bowel preparation. The data suggest that learning water exchange by a busy colonoscopist in a community practice setting is feasible and outcomes conform to accepted quality standards.
Collapse
|
10
|
Leung F, Cheung R, Fan R, Fischer L, Friedland S, Ho S, Hsieh Y, Hung I, Li M, Matsui S, McQuaid K, Ohning G, Ojuri A, Sato T, Shergill A, Shoham M, Simons T, Walter M, Yen A. The water exchange method for colonoscopy-effect of coaching. JOURNAL OF INTERVENTIONAL GASTROENTEROLOGY 2012; 2:122-125. [PMID: 23805391 DOI: 10.4161/jig.23732] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2012] [Revised: 06/05/2012] [Accepted: 06/07/2012] [Indexed: 02/07/2023]
Abstract
The growing popularity of water immersion is supported by its long history as an adjunct to air insufflation; after facilitating colonoscope passage, the infused water is conveniently removed during withdrawal. Water exchange, a modification of water immersion to minimize discomfort in scheduled unsedated patients in the U.S. is new. Even though it may be superior in reducing pain and increasing adenoma detection, the paradigm shift to complete exclusion of air during insertion necessitates removal of infused water containing residual feces, a step often perceived as laborious and time-consuming. The nuances are the efficient steps to remove infused water predominantly during insertion to maintain minimal distension and deliver salvage cleansing. Mastery of the novel maneuvers with practice returns insertion time towards baseline. In this observational study the impact of direct verbal coaching on the primary outcome of intention-to-treat cecal intubation was assessed. The results showed that 14 of 19 (74%) experienced colonoscopists achieved 100% intention-to-treat cecal intubation. Initiation of the examination with water exchange did not preclude completion when conversion to the more familiar air insufflation method was deemed necessary to achieve cecal intubation (total 98%). The overall intention-to-treat cecal intubation rate was 88%, 90% in male and 87% in female. Only 2.7% of bowel preparation was rated as poor during withdrawal. The mean volume of water infused and cecal intubation time was 1558 ml and 18 min, respectively. Direct coaching appears to facilitate understanding of the nuances of the water exchange method. Studies of individual learning curves are necessary.
Collapse
Affiliation(s)
- Fw Leung
- Gastroenterology, Sepulveda ACC, VAGLAHS, North Hills, CA, United States ; Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with an increase in adenoma detection rate - review of data in randomized controlled trials (RCTs) of water-related methods. JOURNAL OF INTERVENTIONAL GASTROENTEROLOGY 2011; 1:121-126. [PMID: 22163082 DOI: 10.4161/jig.1.3.18517] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Revised: 06/18/2011] [Accepted: 06/20/2011] [Indexed: 02/06/2023]
Abstract
INTRODUCTION: Variation in outcomes in RcTs comparing water-related methods and air insufflation raises challenging questions regarding the new approach. This report reviews impact of water exchange - simultaneous infusion and removal of infused water during insertion on adenoma detection rate (ADR) defined as proportion of patients with a least one adenoma of any size. METHODS: Medline (2008-2011) searches, abstract of 2011 Digestive Disease Week (DDW) meeting and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of colonoscope. RESULTS: Since 2008, eleven reports of RcTs (6 published, 1 submitted and 4 abstracts, n=1728) described ADR in patients randomized to be examined by air and water-related methods. The water-related methods differed in timing of removal of the infused water -predominantly during insertion (water exchange) (n=825) or predominantly during withdrawal (water immersion) (n=903). Water immersion was associated with both increases and decreases in ADR compared to respective air method patients and the net overall change (-7%) was significant. On the other hand water exchange was associated with increases in ADR consistently and the net changes (overall, 8%; proximal overall, 11%; and proximal <10 mm, 12%) were all significant. CONCLUSION: Comparative data generated the hypothesis that significantly larger increases in overall and proximal colon ADRs were associated with water exchange than water immersion or air insufflation during insertion. The hypothesis should be evaluated by RCTs to elucidate the mechanism of water exchange on adenoma detection.
Collapse
Affiliation(s)
- Fw Leung
- Sepulveda ACC, VAGLAHS, North Hill, CA, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with a greater reduction of pain score - review of randomized controlled trials (RCTs) of water method colonoscopy. JOURNAL OF INTERVENTIONAL GASTROENTEROLOGY 2011; 1:114-120. [PMID: 22163081 DOI: 10.4161/jig.1.3.18510] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Revised: 05/29/2011] [Accepted: 06/03/2011] [Indexed: 02/06/2023]
Abstract
INTRODUCTION: Variation in the outcomes in RcTs comparing water-related methods and air insufflation during the insertion phase of colonoscopy raises challenging questions regarding the approach. This report reviews the impact of water exchange on the variation in attenuation of pain during colonoscopy by water-related methods. METHODS: Medline (2008 to 2011) searches, abstracts of the 2011 Digestive Disease Week (DDW) and personal communications were considered to identify RcTs that compared water-related methods and air insufflation to aid insertion of the colonoscope. Results: Since 2008 nine published and one submitted RcTs and five abstracts of RcTs presented at the 2011 DDW have been identified. Thirteen RcTs (nine published, one submitted and one abstract, n=1850) described reduction of pain score during or after colonoscopy (eleven reported statistical significance); the remaining reports described lower doses of medication used, or lower proportion of patients experiencing severe pain in colonoscopy performed with water-related methods compared with air insufflation (Tables 1 and 2). The water-related methods notably differ in the timing of removal of the infused water - predominantly during insertion (water exchange) versus predominantly during withdrawal (water immersion). Use of water exchange was consistently associated with a greater attenuation of pain score in patients who did not receive full sedation (Table 3). CONCLUSION: The comparative data reveal that a greater attenuation of pain was associated with water exchange than water immersion during insertion. The intriguing results should be subjected to further evaluation by additional RcTs to elucidate the mechanism of the pain-alleviating impact of the water method.
Collapse
Affiliation(s)
- Fw Leung
- Sepulveda ACC, VAGLAHS, North Hill, CA; USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Bak AW. The water method - untapped potential in extended flexible sigmoidoscopy for colorectal cancer screening? JOURNAL OF INTERVENTIONAL GASTROENTEROLOGY 2011; 1:191-192. [PMID: 22586536 PMCID: PMC3350894 DOI: 10.4161/jig.1.4.19972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Revised: 01/18/2012] [Accepted: 01/19/2012] [Indexed: 01/20/2023]
|