1
|
Lee JR, Yang SW, Kwon CI, Kim KS, Park SH, Jang MJ, Kim GH, Sung MJ, Kim G, Son JS, Joung YK. Anti-fibrotic and anti-stricture effects of biodegradable biliary stents braided with dexamethasone-impregnated sheath/core structured monofilaments. Acta Biomater 2024; 178:137-146. [PMID: 38447810 DOI: 10.1016/j.actbio.2024.02.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 01/22/2024] [Accepted: 02/22/2024] [Indexed: 03/08/2024]
Abstract
Endoscopic biliary stent insertion has been widely used for the treatment of benign biliary stricture (BBS). Thus, the development of stent materials in the perspectives of structure, mechanical properties, and biocompatibility has been also studied. However, conventional metal and plastic stents have several disadvantages, such as repeated procedures to remove or exchange them, dislodgment, restenosis, biocompatibility, and poor mechanical properties. Sustainable effectiveness, attenuation and prevention of fibrosis, and biocompatibility are key factors for the clinical application of stents to BBS treatment. In addition, loading drugs could show synergistic effects with stents' own performance. We developed a dexamethasone-eluting biodegradable stent (DBS) consisting of a sheath/core structure with outstanding mechanical properties and sustained release of dexamethasone, which maintained its functions in a BBS duct over 12 weeks in a swine model. The insertion of our DBS not only expanded BBS areas but also healed secondary ulcers as a result of the attenuation of fibrosis. After 16 weeks from the insertion, BBS areas were totally improved, and the DBS was degraded and thoroughly disappeared without re-intervention for stent removal. Our DBS would be an effective clinical tool for non-vascular diseases. STATEMENT OF SIGNIFICANCE: This study describes the insertion of a drug-eluting biodegradable stent (DBS) into the bile duct. The sheath/core structure of DBS confers substantial durability and a sustained drug release profile. Drug released from the DBS exhibited anti-fibrotic effects without inflammatory responses in both in vitro and in vivo experiments. The DBS maintained its function over 12 weeks after insertion into the common bile duct, expanding benign biliary stricture (BBS) and reducing inflammation to heal secondary ulcers in a swine BBS model. After 16 weeks from the DBS insertion, the DBS thoroughly disappeared without re-intervention for stent removal, resulting in totally improved BBS areas. Our findings not only spotlight the understanding of the sheath/core structure of the biodegradable stent, but also pave the way for the further application for non-vascular diseases.
Collapse
Affiliation(s)
- Ju-Ro Lee
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - Seung Won Yang
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, University of Science and Technology, Daejeon 34113, Republic of Korea
| | - Chang-Il Kwon
- Digestive Disease Center, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam-si, Republic of Korea.
| | - Kyu Seok Kim
- Interventional Research Center, M. I. Tech, Co. Ltd., Pyeongtaek, Republic of Korea
| | - Se Hwan Park
- Interventional Research Center, M. I. Tech, Co. Ltd., Pyeongtaek, Republic of Korea
| | - Myeong Jin Jang
- Korea Textile Development Institute, Daegu 41842, Republic of Korea
| | - Ga Hee Kim
- Korea Textile Development Institute, Daegu 41842, Republic of Korea
| | - Min Je Sung
- Digestive Disease Center, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam-si, Republic of Korea
| | - Gwangil Kim
- Department of Pathology, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam-si, Republic of Korea
| | - Jun Sik Son
- Korea Textile Development Institute, Daegu 41842, Republic of Korea.
| | - Yoon Ki Joung
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, University of Science and Technology, Daejeon 34113, Republic of Korea.
| |
Collapse
|
2
|
Kim JH, Ha DH, Han ES, Choi Y, Koh J, Joo I, Kim JH, Cho DW, Han JK. Feasibility and safety of a novel 3D-printed biodegradable biliary stent in an in vivo porcine model: a preliminary study. Sci Rep 2022; 12:15875. [PMID: 36151222 PMCID: PMC9508112 DOI: 10.1038/s41598-022-19317-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/26/2022] [Indexed: 11/24/2022] Open
Abstract
To assess the feasibility and safety of a novel 3D-printed biodegradable biliary stent using polycaprolactone (PCL) in an in vivo porcine model. In this animal study using domestic pigs, biodegradable radiopaque biliary stents made of polycaprolactone (PCL) and barium sulfate were produced using 3D printing and surgically inserted into the common bile duct (CBD) of pigs (stent group, n = 12). Another five pigs were allocated to the control group that only underwent resection and anastomosis of the CBD without stent insertion. To check the position and status of the stents and stent-related complications, follow-up computed tomography (CT) was performed every month. The pigs were sacrificed 1 or 3 months after surgery, and their excised CBD specimens were examined at both the macroscopic and microscopic levels. Three pigs (one in the stent group and two in the control group) died within one day after surgery and were excluded from further analysis; the remaining 11 in the stent group and 3 in the control group survived the scheduled follow-up period (1 month, 5 and 1; and 3 months, 6 and 2 in stent and control groups, respectively). In all pigs, no clinical symptoms or radiologic evidence of biliary complications was observed. In the stent group (n = 11), stent migration (n = 1 at 3 months; n = 2 at 1 month) and stent fracture (n = 3 at 2 months) were detected on CT scans. Macroscopic evaluation of the stent indicated no significant change at 1 month (n = 3) or fragmentation with discoloration at 3 months (n = 5). On microscopic examination of CBD specimens, the tissue inflammation score was significantly higher in the stent group than in the control group (mean ± standard deviation (SD), 5.63 ± 2.07 vs. 2.00 ± 1.73; P = 0.039) and thickness of fibrosis of the CBD wall was significantly higher than that of the control group (0.46 ± 0.12 mm vs. 0.21 ± 0.05 mm; P = 0.012). Despite mild bile duct inflammation and fibrosis, 3D-printed biodegradable biliary stents showed good feasibility and safety in porcine bile ducts, suggesting their potential for use in the prevention of postoperative biliary strictures.
Collapse
Affiliation(s)
- Jae Hyun Kim
- Department of Radiology, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul, 110-744, Republic of Korea
| | - Dong-Heon Ha
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea
| | - Eui Soo Han
- Department of Surgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - YoungRok Choi
- Department of Surgery, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jiwon Koh
- Department of Pathology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul, 110-744, Republic of Korea
| | - Jung Hoon Kim
- Department of Radiology, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul, 110-744, Republic of Korea
| | - Dong-Woo Cho
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital, 28, Yongon-dong, Chongno-gu, Seoul, 110-744, Republic of Korea.
| |
Collapse
|