1
|
Schinas G, Polyzou E, Spernovasilis N, Gogos C, Dimopoulos G, Akinosoglou K. Preventing Multidrug-Resistant Bacterial Transmission in the Intensive Care Unit with a Comprehensive Approach: A Policymaking Manual. Antibiotics (Basel) 2023; 12:1255. [PMID: 37627675 PMCID: PMC10451180 DOI: 10.3390/antibiotics12081255] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 07/25/2023] [Accepted: 07/27/2023] [Indexed: 08/27/2023] Open
Abstract
Patients referred to intensive care units (ICU) commonly contract infections caused by multidrug-resistant (MDR) bacteria, which are typically linked to complications and high mortality. There are numerous independent factors that are associated with the transmission of these pathogens in the ICU. Preventive multilevel measures that target these factors are of great importance in order to break the chain of transmission. In this review, we aim to provide essential guidance for the development of robust prevention strategies, ultimately ensuring the safety and well-being of patients and healthcare workers in the ICU. We discuss the role of ICU personnel in cross-contamination, existing preventative measures, novel technologies, and strategies employed, along with antimicrobial surveillance and stewardship (AMSS) programs, to construct effective and thoroughly described policy recommendations. By adopting a multifaceted approach that combines targeted interventions with broader preventive strategies, healthcare facilities can create a more coherent line of defense against the spread of MDR pathogens. These recommendations are evidence-based, practical, and aligned with the needs and realities of the ICU setting. In conclusion, this comprehensive review offers a blueprint for mitigating the risk of MDR bacterial transmission in the ICU, advocating for an evidence-based, multifaceted approach.
Collapse
Affiliation(s)
- Georgios Schinas
- Department of Medicine, University of Patras, 26504 Patras, Greece; (G.S.); (E.P.); (C.G.); (K.A.)
| | - Elena Polyzou
- Department of Medicine, University of Patras, 26504 Patras, Greece; (G.S.); (E.P.); (C.G.); (K.A.)
- Department of Internal Medicine and Infectious Diseases, University General Hospital of Patras, 26504 Patras, Greece
| | | | - Charalambos Gogos
- Department of Medicine, University of Patras, 26504 Patras, Greece; (G.S.); (E.P.); (C.G.); (K.A.)
| | - George Dimopoulos
- 3rd Department of Critical Care, Evgenidio Hospital, Medical School, National and Kapodistrian University of Athens, 11528 Athens, Greece;
| | - Karolina Akinosoglou
- Department of Medicine, University of Patras, 26504 Patras, Greece; (G.S.); (E.P.); (C.G.); (K.A.)
- Department of Internal Medicine and Infectious Diseases, University General Hospital of Patras, 26504 Patras, Greece
| |
Collapse
|
2
|
Christenson EC, Cronk R, Atkinson H, Bhatt A, Berdiel E, Cawley M, Cho G, Coleman CK, Harrington C, Heilferty K, Fejfar D, Grant EJ, Grigg K, Joshi T, Mohan S, Pelak G, Shu Y, Bartram J. Evidence Map and Systematic Review of Disinfection Efficacy on Environmental Surfaces in Healthcare Facilities. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:11100. [PMID: 34769620 PMCID: PMC8582915 DOI: 10.3390/ijerph182111100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/19/2021] [Accepted: 10/20/2021] [Indexed: 01/23/2023]
Abstract
Healthcare-associated infections (HAIs) contribute to patient morbidity and mortality with an estimated 1.7 million infections and 99,000 deaths costing USD $28-34 billion annually in the United States alone. There is little understanding as to if current environmental surface disinfection practices reduce pathogen load, and subsequently HAIs, in critical care settings. This evidence map includes a systematic review on the efficacy of disinfecting environmental surfaces in healthcare facilities. We screened 17,064 abstracts, 635 full texts, and included 181 articles for data extraction and study quality assessment. We reviewed ten disinfectant types and compared disinfectants with respect to study design, outcome organism, and fourteen indictors of study quality. We found important areas for improvement and gaps in the research related to study design, implementation, and analysis. Implementation of disinfection, a determinant of disinfection outcomes, was not measured in most studies and few studies assessed fungi or viruses. Assessing and comparing disinfection efficacy was impeded by study heterogeneity; however, we catalogued the outcomes and results for each disinfection type. We concluded that guidelines for disinfectant use are primarily based on laboratory data rather than a systematic review of in situ disinfection efficacy. It is critically important for practitioners and researchers to consider system-level efficacy and not just the efficacy of the disinfectant.
Collapse
Affiliation(s)
- Elizabeth C. Christenson
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Ryan Cronk
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
- ICF, Durham, NC 27713, USA
| | - Helen Atkinson
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Aayush Bhatt
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Emilio Berdiel
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Michelle Cawley
- Health Sciences Library, University of North Carolina, Chapel Hill, NC 27599, USA; (M.C.); (K.G.); (G.P.)
| | - Grace Cho
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Collin Knox Coleman
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Cailee Harrington
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Kylie Heilferty
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Don Fejfar
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Emily J. Grant
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Karen Grigg
- Health Sciences Library, University of North Carolina, Chapel Hill, NC 27599, USA; (M.C.); (K.G.); (G.P.)
| | - Tanmay Joshi
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Suniti Mohan
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Grace Pelak
- Health Sciences Library, University of North Carolina, Chapel Hill, NC 27599, USA; (M.C.); (K.G.); (G.P.)
| | - Yuhong Shu
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
| | - Jamie Bartram
- The Water Institute, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599, USA; (E.C.C.); (R.C.); (H.A.); (A.B.); (E.B.); (G.C.); (C.K.C.); (C.H.); (K.H.); (D.F.); (E.J.G.); (T.J.); (S.M.); (Y.S.)
- School of Civil Engineering, University of Leeds, Leeds LS2 9DY, UK
| |
Collapse
|
3
|
Choi J, Lee M, Lee Y, Song Y, Cho Y, Lim TH. Effectiveness of Plasma-Treated Hydrogen Peroxide Mist Disinfection in Various Hospital Environments. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:9841. [PMID: 34574763 PMCID: PMC8467658 DOI: 10.3390/ijerph18189841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/14/2021] [Accepted: 09/14/2021] [Indexed: 11/30/2022]
Abstract
Hospital environments are associated with a high risk of infection. As plasma-treated hydrogen peroxide mist disinfection has a higher disinfection efficacy, we tested the efficacy of plasma-treated hydrogen peroxide mist disinfection on several surfaces in various hospital environments. Disinfection was performed in 23 rooms across different hospital environments, including hospital wards, outpatient departments (OPDs), and emergency rooms. A total of 459 surfaces were swabbed before/after disinfection. Surfaces were also divided into plastic, metal, wood, leather, ceramic, silicone, and glass for further analyses. Only gram-positive bacteria were statistically analyzed because the number of gram-negative bacteria and mold was insufficient. Most colony-forming units (CFUs) of gram-positive bacteria were observed in OPDs and on leather materials before disinfection. The proportion of surfaces that showed a percentage decrease in CFU values of more than 90% after disinfection were as follows: OPDs (85%), hospital wards (99%), and emergency rooms (100%); plastic (97%), metal (83%), wood (84%), leather (81%), and others (87%). Plasma-treated hydrogen peroxide mist disinfection resulted in a significant decrease in the CFU values of gram-positive bacteria in various environments. Plasma-treated hydrogen peroxide mist disinfection is an effective and efficient method of disinfecting various hospital environments.
Collapse
Affiliation(s)
- Jongbong Choi
- Department of Biomedical Engineering, Hanyang University, Seoul 04763, Korea; (J.C.); (M.L.)
| | - Minhyuk Lee
- Department of Biomedical Engineering, Hanyang University, Seoul 04763, Korea; (J.C.); (M.L.)
| | - Yangsoon Lee
- Department of Laboratory Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea;
| | - Yeongtak Song
- Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea; (Y.S.); (Y.C.)
| | - Yongil Cho
- Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea; (Y.S.); (Y.C.)
| | - Tae Ho Lim
- Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea; (Y.S.); (Y.C.)
| |
Collapse
|
4
|
Yiek WK, Coenen O, Nillesen M, van Ingen J, Bowles E, Tostmann A. Outbreaks of healthcare-associated infections linked to water-containing hospital equipment: a literature review. Antimicrob Resist Infect Control 2021; 10:77. [PMID: 33971944 PMCID: PMC8108015 DOI: 10.1186/s13756-021-00935-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 04/09/2021] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Healthcare-associated infections (HAIs) are a significant cause of morbidity and mortality in hospitalized patients. Water in the environment can be a source of infection linked to outbreaks and environmental transmission in hospitals. Water safety in hospitals remains a challenge. This article has summarized available scientific literature to obtain an overview of outbreaks linked to water-containing hospital equipment and strategies to prevent such outbreaks. METHODS We made a list of water-containing hospital equipment and devices in which water is being used in a semi-closed circuit. A literature search was performed in PubMed with a search strategy containing the names of these medical devices and one or more of the following words: outbreak, environmental contamination, transmission, infection. For each medical device, we summarized the following information: the function of the medical device, causes of contamination, the described outbreaks and possible prevention strategies. RESULTS The following water-containing medical equipment or devices were identified: heater-cooler units, hemodialysis equipment, neonatal incubators, dental unit waterlines, fluid warmers, nebulizers, water traps, water baths, blanketrol, scalp cooling, and thermic stimulators. Of the latter three, no literature could be found. Of all other devices, one or more outbreaks associated with these devices were reported in the literature. CONCLUSIONS The water reservoirs in water-containing medical devices can be a source of microbial growth and transmissions to patients, despite the semi-closed water circuit. Proper handling and proper cleaning and disinfection can help to reduce the microbial burden and, consequently, transmission to patients. However, these devices are often difficult to clean and disinfect because they cannot be adequately opened or disassembled, and the manufacturer's cleaning guidelines are often not feasible to execute. The development of equipment without water or fluid containers should be stimulated. Precise cleaning and disinfection guidelines and instructions are essential for instructing healthcare workers and hospital cleaning staff to prevent potential transmission to patients.
Collapse
Affiliation(s)
- Wing-Kee Yiek
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Olga Coenen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Mayke Nillesen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Jakko van Ingen
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Edmée Bowles
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Alma Tostmann
- Department of Medical Microbiology, Radboud Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands.
| |
Collapse
|
5
|
Sebre S, Abegaz WE, Seman A, Awoke T, Desalegn Z, Mihret W, Mihret A, Abebe T. Bacterial Profiles and Antimicrobial Susceptibility Pattern of Isolates from Inanimate Hospital Environments at Tikur Anbessa Specialized Teaching Hospital, Addis Ababa, Ethiopia. Infect Drug Resist 2020; 13:4439-4448. [PMID: 33364791 PMCID: PMC7751703 DOI: 10.2147/idr.s286293] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Accepted: 11/30/2020] [Indexed: 12/18/2022] Open
Abstract
Introduction Microbial contamination of the hospital environment plays an important role in the spread of healthcare-associated infections (HCAIs). This study was conducted to determine bacterial contamination, bacterial profiles, and antimicrobial susceptibility pattern of bacterial isolates from environmental surfaces and medical equipment. Methods A cross-sectional study was conducted at Tikur Anbessa Specialized Hospital (TASH) from June to September 2018. A total of 164 inanimate surfaces located at intensive care units (ICUs) and operation theaters (OTs) were swabbed. All isolates were identified by using routine bacterial culture, Gram staining, and a panel of biochemical tests. For each identified bacteria, antibiogram profiles were determined by the Kirby–Bauer disk diffusion method according to the guidelines of the Clinical and Laboratory Standards Institute (CLSI). Results Out of the 164 swabbed samples, 141 (86%) were positive for bacterial growth. The predominant bacteria identified from OTs and ICUs were Staphylococci aureus (23% vs 11.5%), Acinetobacter baumannii (3.8% vs 17.5%) and coagulase-negative Staphylococcus (CoNS) (12.6% vs 2.7%) respectively. Linens were the most contaminated materials among items studied at the hospital (14.8%). Gram-positive bacteria (GPB) had significantly high resistance levels to penicillin (92.8%), cefoxitin (83.5%), and erythromycin (53.6%). On the other hand, Gram-negative bacteria (GNB) revealed the highest resistance levels to ampicillin (97.5%), ceftazidime (91.3%), ceftriaxone (91.3%), and aztreonam (90%). However, a low resistance level was recorded for amikacin (25%) followed by Ciprofloxacin (37.5%). Of the 63 S. aureus isolates, 54 (85.7%) were methicillin-resistant S. aureus (MRSA). Conclusion The inanimate surfaces and commonly touched medical equipment within OTs and ICUs are reservoirs of potentially pathogenic bacteria that could predispose critically ill patients to acquire HCAIs. The proportions of the antimicrobial resistance profile of the isolates are much higher from studied clean inanimate environments.
Collapse
Affiliation(s)
- Shemse Sebre
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Woldaregay Erku Abegaz
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Aminu Seman
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Tewachew Awoke
- Department of Medical Laboratory Sciences, College of Medicine and Health Sciences, Bahir Dar University, Bahir Dar, Ethiopia
| | - Zelalem Desalegn
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Wude Mihret
- Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Adane Mihret
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Tamrat Abebe
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| |
Collapse
|
6
|
Metapopulation Model from Pathogen's Perspective: A Versatile Framework to Quantify Pathogen Transfer and Circulation between Environment and Hosts. Sci Rep 2019; 9:1694. [PMID: 30737423 PMCID: PMC6368549 DOI: 10.1038/s41598-018-37938-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Accepted: 12/18/2018] [Indexed: 02/06/2023] Open
Abstract
Metapopulation models have been primarily explored in infectious disease epidemiology to study host subpopulation movements and between-host contact structures. They also have the potential to investigate environmental pathogen transferring. In this study, we demonstrate that metapopulation models serve as an ideal modeling framework to characterize and quantify pathogen transfer between environment and hosts. It therefore unifies host, pathogen, and environment, collectively known as the epidemiological triad, a fundamental concept in epidemiology. We develop a customizable and generalized pathogen-transferring model where pathogens dwell in and transferring (via contact) between environment and hosts. We analyze three specific case studies: pure pathogen transferring without pathogen demography, source-sink dynamics, and pathogen control via external disinfection. We demonstrate how pathogens circulate in the system between environment and hosts, as well as evaluate different controlling efforts for healthcare-associated infections (HAIs). For pure pathogen transferring, system equilibria can be derived analytically to explicitly quantify long-term pathogen distribution in the system. For source-sink dynamics and pathogen control via disinfection, we demonstrate that complete eradication of pathogens can be achieved, but the rates of converging to system equilibria differ based on specific model parameterization. Direct host-host pathogen transferring and within-host dynamics can be future directions of this modeling framework by adding specific modules.
Collapse
|
7
|
Chen S, Lenhart S, Day JD, Lee C, Dulin M, Lanzas C. Pathogen transfer through environment-host contact: an agent-based queueing theoretic framework. MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA 2018; 35:409-425. [PMID: 29106583 DOI: 10.1093/imammb/dqx014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Accepted: 09/29/2017] [Indexed: 12/12/2022]
Abstract
Queueing theory studies the properties of waiting queues and has been applied to investigate direct host-to-host transmitted disease dynamics, but its potential in modelling environmentally transmitted pathogens has not been fully explored. In this study, we provide a flexible and customizable queueing theory modelling framework with three major subroutines to study the in-hospital contact processes between environments and hosts and potential nosocomial pathogen transfer, where environments are servers and hosts are customers. Two types of servers with different parameters but the same utilization are investigated. We consider various forms of transfer functions that map contact duration to the amount of pathogen transfer based on existing literature. We propose a case study of simulated in-hospital contact processes and apply stochastic queues to analyse the amount of pathogen transfer under different transfer functions, and assume that pathogen amount decreases during the inter-arrival time. Different host behaviour (feedback and non-feedback) as well as initial pathogen distribution (whether in environment and/or in hosts) are also considered and simulated. We assess pathogen transfer and circulation under these various conditions and highlight the importance of the nonlinear interactions among contact processes, transfer functions and pathogen demography during the contact process. Our modelling framework can be readily extended to more complicated queueing networks to simulate more realistic situations by adjusting parameters such as the number and type of servers and customers, and adding extra subroutines.
Collapse
Affiliation(s)
- Shi Chen
- Department of Public Health Sciences, University of North Carolina Charlotte, Charlotte, NC, USA.,Department of Population Health and Pathobiology, North Carolina State University, Raleigh, NC, USA
| | - Suzanne Lenhart
- Department of Population Health and Pathobiology, North Carolina State University, Raleigh, NC, USA
| | - Judy D Day
- Department of Mathematics, University of Tennessee, Knoxville, TN 37996, USA.,Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN, USA
| | - Chihoon Lee
- School of Business, Stevens Institute of Technology, Hoboken, NJ 07030, USA
| | - Michael Dulin
- Department of Public Health Sciences, University of North Carolina Charlotte, Charlotte, NC, USA
| | - Cristina Lanzas
- Department of Population Health and Pathobiology, North Carolina State University, Raleigh, NC, USA
| |
Collapse
|
8
|
Wan GH, Huang CG, Chung FF, Lin TY, Tsao KC, Huang YC. Detection of Common Respiratory Viruses and Mycoplasma pneumoniae in Patient-Occupied Rooms in Pediatric Wards. Medicine (Baltimore) 2016; 95:e3014. [PMID: 27057827 PMCID: PMC4998743 DOI: 10.1097/md.0000000000003014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Few studies have assessed viral contamination in the rooms of hospital wards. This cross-sectional study evaluated the air and objects in patient-occupied rooms in pediatric wards for the presence of common respiratory viruses and Mycoplasma pneumoniae.Air samplers were placed at a short (60-80 cm) and long (320 cm) distance from the head of the beds of 58 pediatric patients, who were subsequently confirmed to be infected with enterovirus (n = 17), respiratory syncytial virus (RSV) (n = 13), influenza A virus (n = 13), adenovirus (n = 9), or M pneumoniae (n = 6). Swab samples were collected from the surfaces of 5 different types of objects in the patients' rooms. All air and swab samples were analyzed via real-time quantitative polymerase chain reaction assay for the presence of the above pathogens.All pathogens except enterovirus were detected in the air, on the objects, or in both locations in the patients' rooms. The detection rates of influenza A virus, adenovirus, and M pneumoniae for the long distance air sampling were 15%, 67%, and 17%, respectively. Both adenovirus and M pneumoniae were detected at very high rates, with high concentrations, on all sampled objects.The respiratory pathogens RSV, influenza A virus, adenovirus, and M pneumoniae were detected in the air and/or on the objects in the pediatric ward rooms. Appropriate infection control measures should be strictly implemented when caring for such patients.
Collapse
Affiliation(s)
- Gwo-Hwa Wan
- From the Department of Respiratory Therapy, College of Medicine (G-HW), College of Medicine (T-YL, Y-CH), and Department of Biotechnology and Laboratory Science, Research Center for Emerging Viral Infections (C-GH, K-CT), Chang Gung University; Department of Neurosurgery (G-HW), Laboratory Medicine (C-GH, K-CT) and Division of Pediatric Infectious Diseases (T-YL, Y-CH), Chang Gung Memorial Hospital; Department of Nursing, Chang Gung University of Science and Technology (F-FC), Tao-Yuan, Taiwan, R.O.C
| | | | | | | | | | | |
Collapse
|
9
|
Russotto V, Cortegiani A, Raineri SM, Giarratano A. Bacterial contamination of inanimate surfaces and equipment in the intensive care unit. J Intensive Care 2015; 3:54. [PMID: 26693023 PMCID: PMC4676153 DOI: 10.1186/s40560-015-0120-5] [Citation(s) in RCA: 156] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Accepted: 12/02/2015] [Indexed: 11/24/2022] Open
Abstract
Intensive care unit (ICU)-acquired infections are a challenging health problem worldwide, especially when caused by multidrug-resistant (MDR) pathogens. In ICUs, inanimate surfaces and equipment (e.g., bedrails, stethoscopes, medical charts, ultrasound machine) may be contaminated by bacteria, including MDR isolates. Cross-transmission of microorganisms from inanimate surfaces may have a significant role for ICU-acquired colonization and infections. Contamination may result from healthcare workers’ hands or by direct patient shedding of bacteria which are able to survive up to several months on dry surfaces. A higher environmental contamination has been reported around infected patients than around patients who are only colonized and, in this last group, a correlation has been observed between frequency of environmental contamination and culture-positive body sites. Healthcare workers not only contaminate their hands after direct patient contact but also after touching inanimate surfaces and equipment in the patient zone (the patient and his/her immediate surroundings). Inadequate hand hygiene before and after entering a patient zone may result in cross-transmission of pathogens and patient colonization or infection. A number of equipment items and commonly used objects in ICU carry bacteria which, in most cases, show the same antibiotic susceptibility profiles of those isolated from patients. The aim of this review is to provide an updated evidence about contamination of inanimate surfaces and equipment in ICU in light of the concept of patient zone and the possible implications for bacterial pathogen cross-transmission to critically ill patients.
Collapse
Affiliation(s)
- Vincenzo Russotto
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anaesthesia, Analgesia, Intensive Care and Emergency, University Hospital Paolo Giaccone, University of Palermo, Via del Vespro 129, 90127 Palermo, Italy
| | - Andrea Cortegiani
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anaesthesia, Analgesia, Intensive Care and Emergency, University Hospital Paolo Giaccone, University of Palermo, Via del Vespro 129, 90127 Palermo, Italy
| | - Santi Maurizio Raineri
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anaesthesia, Analgesia, Intensive Care and Emergency, University Hospital Paolo Giaccone, University of Palermo, Via del Vespro 129, 90127 Palermo, Italy
| | - Antonino Giarratano
- Department of Biopathology and Medical Biotechnologies (DIBIMED), Section of Anaesthesia, Analgesia, Intensive Care and Emergency, University Hospital Paolo Giaccone, University of Palermo, Via del Vespro 129, 90127 Palermo, Italy
| |
Collapse
|
10
|
Gong Z, Du H, Cheng F, Wang C, Wang C, Fan M. Fabrication of SERS swab for direct detection of trace explosives in fingerprints. ACS APPLIED MATERIALS & INTERFACES 2014; 6:21931-7. [PMID: 25455731 DOI: 10.1021/am507424v] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Swab sampling is of great importance in surface contamination analysis. A cotton swab (cotton Q-tip) was successfully transformed into surface-enhanced Raman scattering (SERS) substrate (SERS Q-tip) through a bottom-up strategy, where Ag NPs were first self-assembled onto the Q-tip followed by in situ growing. The capability for direct swab detection of Raman probe Nile Blue A (NBA) and a primary explosive marker 2,4-dinitrotoluene (2,4-DNT) using the SERS Q-tip was explored. It was found that at optimum conditions, a femotogram of NBA on glass surface could be swab-detected. The lowest detectable amount for 2,4-DNT is only ∼1.2 ng/cm(2) (total amount of 5 ng) on glass surface, 2 orders of magnitude more sensitive than similar surface analysis achieved with infrared technique, and comparable even with that obtained by ion mobility spectrometry-mass spectrometry. Finally, 2,4-DNT left on fingerprints was also analyzed. It was found that SERS signal of 2,4-DNT from 27th fingerprint after touching 2,4-DNT powder can still be clearly identified by swabbing with the SERS Q-tip. We believe this is the first direct SERS swabbing test of explosives on fingerprint on glass. Considering its relative long shelf life (>30 d), the SERS Q-tip may find great potential in future homeland security applications when combined with portable Raman spectrometers.
Collapse
Affiliation(s)
- Zhengjun Gong
- Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University , Chengdu, 610031, China
| | | | | | | | | | | |
Collapse
|