1
|
Evolution of coronary artery calcium and absolute myocardial perfusion after percutaneous revascularization: A 3-year serial hybrid [ 15O]H 2O PET/CT imaging study. Atherosclerosis 2020; 318:22-31. [PMID: 33450475 DOI: 10.1016/j.atherosclerosis.2020.12.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 11/27/2020] [Accepted: 12/16/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND AND AIMS The value of serial coronary artery calcium (CAC) scores to predict changes in absolute myocardial perfusion and epicardial vasomotor function is poorly documented. This study explored the association between progression of CAC score and changes in absolute myocardial perfusion. METHODS Fifty-three patients (26% female) with de novo single-vessel coronary artery disease underwent [15O]H2O positron emission tomography/computed tomography at 1 month (baseline), 1 year, and 3 years after complete revascularization with percutaneous coronary intervention (PCI) to assess CAC scores, hyperemic myocardial blood flow (hMBF), coronary flow reserve (CFR) and cold pressor test MBF (CPT-MBF), within the context of the VANISH trial. RESULTS Baseline CAC score was 0 in 9%, 0.1-99.9 in 40%, 100-399.9 in 36% and ≥400 in 15% of patients, respectively. Mixed model-analysis allowed for averaging perfusion indices over all time points: hMBF (3.74 ± 0.83; 3.33 ± 0.79; 3.08 ± 0.78 and 2.44 ± 0.74 mL min-1·g-1) and CFR (3.82 ± 1.12; 3.17 ± 0.80; 3.19 ± 0.81; 2.63 ± 0.92) were lower among higher baseline CAC groups (p < 0.01; p = 0.03). However, no significant interaction was found between baseline CAC groups and time after PCI for all perfusion indices, denoting that evolution of perfusion indices over time was not significantly different between CAC groups. Furthermore, CAC progression was not correlated with evolution of hMBF (r = 0.08, p = 0.57), CFR (r = 0.09, p = 0.53) or CPT-MBF (r = 0.03, p = 0.82) during 3 years of follow-up. CONCLUSIONS Higher baseline CAC was associated with lower hMBF and CFR. However, both baseline CAC and its progression were not associated with evolution of absolute hMBF, CFR and CPT-MBF over time, suggesting that CAC score and progression of CAC are poor indicators of change in absolute myocardial perfusion.
Collapse
|
2
|
Kawashima H, Zocca P, Buiten RA, Smits PC, Onuma Y, Wykrzykowska JJ, de Winter RJ, von Birgelen C, Serruys PW. The 2010s in clinical drug-eluting stent and bioresorbable scaffold research: a Dutch perspective. Neth Heart J 2020; 28:78-87. [PMID: 32780336 PMCID: PMC7419418 DOI: 10.1007/s12471-020-01442-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Dutch researchers were among the first to perform clinical studies in bare metal coronary stents, the use of which was initially limited by a high incidence of in-stent restenosis. This problem was greatly solved by the introduction of drug-eluting stents (DES). Nevertheless, enthusiasm about first-generation DES was subdued by discussions about a higher risk of very-late stent thrombosis and mortality, which stimulated the development, refinement, and rapid adoption of new DES with more biocompatible durable polymer coatings, biodegradable polymer coatings, or no coating at all. In terms of clinical DES research, the 2010s were characterised by numerous large-scale randomised trials in all-comers and patients with minimal exclusion criteria. Bioresorbable scaffolds (BRS) were developed and investigated. The Igaki-Tamai scaffold without drug elution was clinically tested in the Netherlands in 1999, followed by an everolimus-eluting BRS (Absorb) which showed favourable imaging and clinical results. Afterwards, multiple clinical trials comparing Absorb and its metallic counterpart were performed, revealing an increased rate of scaffold thrombosis during follow-up. Based on these studies, the commercialisation of the device was subsequently halted. Novel technologies are being developed to overcome shortcomings of first-generation BRS. In this narrative review, we look back on numerous devices and on the DES and BRS trials reported by Dutch researchers.
Collapse
Affiliation(s)
- H Kawashima
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.,Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - P Zocca
- Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands
| | - R A Buiten
- Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands.,Health Technology and Services Research, Faculty of Behavioural Management and Social Sciences, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - P C Smits
- Department of Cardiology, Maasstad Hospital, Rotterdam, The Netherlands
| | - Y Onuma
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - J J Wykrzykowska
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - R J de Winter
- Department of Clinical and Experimental Cardiology, Heart Center, Amsterdam Cardiovascular Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - C von Birgelen
- Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands.,Health Technology and Services Research, Faculty of Behavioural Management and Social Sciences, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - P W Serruys
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland. .,Imperial College London, London, UK.
| |
Collapse
|
3
|
Pellicano M, Di Gioia G, Ciccarelli G, Xaplanteris P, Delrue L, Toth GG, Van Durme F, Heyse A, Wyffels E, Vanderheyden M, Bartunek J, De Bruyne B, Barbato E. Procedural microvascular activation in long lesions treated with bioresorbable vascular scaffolds or everolimus-eluting stents: the PROACTIVE trial. EUROINTERVENTION 2020; 16:e147-e154. [PMID: 31085503 DOI: 10.4244/eij-d-18-01138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS Significant platelet activation after long stented coronary segments has been associated with periprocedural microvascular impairment and myonecrosis. In long lesions treated either with an everolimus-eluting bioresorbable vascular scaffold (BVS) or an everolimus-eluting stent (EES), we aimed to investigate (a) procedure-related microvascular impairment, and (b) the relationship of platelet activation with microvascular function and related myonecrosis. METHODS AND RESULTS Patients (n=66) undergoing elective percutaneous coronary intervention (PCI) in long lesions were randomised 1:1 to either BVS or EES. The primary endpoint was the difference between groups in changes of pressure-derived corrected index of microvascular resistance (cIMR) after PCI. Periprocedural myonecrosis was assessed by high-sensitivity cardiac troponin T (hs-cTnT), platelet reactivity by high-sensitivity adenosine diphosphate (hs-ADP)-induced platelet reactivity with the Multiplate Analyzer. Post-dilatation was more frequent in the BVS group, with consequent longer procedure time. A significant difference was observed between the two groups in the primary endpoint of ΔcIMR (p=0.04). hs-ADP was not different between the groups at different time points. hs-cTnT significantly increased after PCI, without difference between the groups. CONCLUSIONS In long lesions, BVS implantation is associated with significant acute reduction in IMR as compared with EES, with no significant interaction with platelet reactivity or periprocedural myonecrosis.
Collapse
|
4
|
Stuijfzand WJ, Schumacher SP, Driessen RS, Lammertsma AA, Bakker AL, Rijnierse MT, van Rossum AC, van de Ven PM, Nap A, Appelman Y, van Royen N, van Leeuwen MA, Lemkes JS, Raijmakers PG, Knaapen P. Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation. JACC Cardiovasc Interv 2019; 12:967-979. [DOI: 10.1016/j.jcin.2019.03.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 02/04/2019] [Accepted: 03/05/2019] [Indexed: 10/26/2022]
|
5
|
Rampat R, Williams T, Hildick-Smith D, Cockburn J. The effect of elective implantation of the ABSORB bioresorbable vascular scaffold on coronary microcirculation: Serial assessment using the index of microcirculatory resistance. Microcirculation 2019; 26:e12521. [PMID: 30561875 DOI: 10.1111/micc.12521] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 12/10/2018] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Stenting with metal stents can affect microcirculatory function. The impact of BVS on the microvascular network has not been studied. METHODS A total of 30 patients with bifurcation disease of Medina (X,X,0) scheduled for elective PCI with the ABSORB BVS were studied. Pressure wire studies were performed before and after scaffold implantation and at a mean follow-up of 9 months. At each time point, FFR, IMR, and CFR were calculated using the thermodilution method. RESULTS Following scaffold implantation, FFR change from pre-PCI, post-PCI and follow-up was 0.76, 0.92 and 0.91, respectively (P < 0.001 from pre to post-PCI and P = 0.91 from post-PCI to follow-up). There was a statistically significant improvement between pre- and post-procedural IMR (median 27.7 to 17.9, P = 0.02) and CFR (median 2.2 to 2.9, P = 0.02). Median IMR at follow-up (23.6) remained numerically lower than pre-procedure but this was not statistically significant (P = 0.05). Similarly, while median CFR at follow-up remained at post-procedural level (2.9), this effect did not reach statistical significance (P = 0.06). CONCLUSION There is an immediate reduction in microvascular resistance after elective BVS implantation but this effect is not sustained long term.
Collapse
Affiliation(s)
- Rajiv Rampat
- Sussex Cardiac Centre, Brighton and Sussex University Hospitals, Brighton, UK.,Brighton and Sussex Medical School, Brighton, UK
| | - Timothy Williams
- Sussex Cardiac Centre, Brighton and Sussex University Hospitals, Brighton, UK.,Brighton and Sussex Medical School, Brighton, UK
| | - David Hildick-Smith
- Sussex Cardiac Centre, Brighton and Sussex University Hospitals, Brighton, UK
| | - James Cockburn
- Sussex Cardiac Centre, Brighton and Sussex University Hospitals, Brighton, UK
| |
Collapse
|
6
|
Stone GW, Ellis SG, Gori T, Metzger DC, Stein B, Erickson M, Torzewski J, Williams J, Lawson W, Broderick TM, Kabour A, Piegari G, Cavendish J, Bertolet B, Choi JW, Marx SO, Généreux P, Kereiakes DJ. Blinded outcomes and angina assessment of coronary bioresorbable scaffolds: 30-day and 1-year results from the ABSORB IV randomised trial. Lancet 2018; 392:1530-1540. [PMID: 30266412 DOI: 10.1016/s0140-6736(18)32283-9] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 09/07/2018] [Accepted: 09/12/2018] [Indexed: 12/14/2022]
Abstract
BACKGROUND Previous studies showed more adverse events with coronary bioresorbable vascular scaffolds (BVS) than with metallic drug-eluting stents (DES), although in one randomised trial angina was reduced with BVS. However, these early studies were unmasked, lesions smaller than intended for the scaffold were frequently enrolled, implantation technique was suboptimal, and patients with myocardial infarction, in whom BVS might be well suited, were excluded. METHODS In the active-controlled, blinded, multicentre, randomised ABSORB IV trial, patients with stable coronary artery disease or acute coronary syndromes aged 18 years or older were recruited from 147 hospitals in five countries (the USA, Germany, Australia, Singapore, and Canada). Enrolled patients were randomly assigned (1:1) to receive polymeric everolimus-eluting BVS (Absorb; Abbott Vascular, Santa Clara, CA, USA) with optimised implantation technique or cobalt-chromium everolimus-eluting stents (EES; Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetic status, whether patients would have been eligible for enrolment in the previous ABSORB III trial, and site. Patients and clinical assessors were masked to randomisation. The primary endpoint was target lesion failure (cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation) at 30 days, tested for non-inferiority with a 2·9% margin for the risk difference. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02173379, and is closed to accrual. FINDINGS Between Aug 15, 2014, and March 31, 2017, we screened 18 722 patients for eligibility, 2604 of whom were enrolled. 1296 patients were assigned to BVS, and 1308 patients were assigned to EES. Follow-up data at 30 days and 1 year, respectively, were available for 1288 and 1254 patients with BVS and for 1303 and 1272 patients with EES. Biomarker-positive acute coronary syndromes were present in 622 (24%) of 2602 patients, and, by angiographic core laboratory analysis, 78 (3%) of 2893 of lesions were in very small vessels. Target lesion failure at 30 days occurred in 64 (5·0%) patients assigned to BVS and 48 (3·7%) patients assigned to EES (difference 1·3%, upper 97·5% confidence limit 2·89; one-sided pnon-inferiority=0·0244). Target lesion failure at 1 year occurred in 98 (7·8%) patients assigned to BVS and 82 (6·4%) patients assigned to EES (difference 1·4%, upper 97·5% confidence limit 3·4; one-sided pnon-inferiority=0·0006). Angina, adjudicated by a central events committee at 1 year, occurred in 270 (20·3%) patients assigned to BVS and 274 (20·5%) patients assigned to EES (difference -0·3%, 95% CI -3·4% to 2·9%; one-sided pnon-inferiority=0·0008; two-sided psuperiority=0·8603). Device thrombosis within 1 year occurred in nine (0·7%) patients assigned to BVS and four (0·3%) patients assigned to EES (p=0·1586). INTERPRETATION Polymeric BVS implanted with optimised technique in an expanded patient population resulted in non-inferior 30-day and 1-year rates of target lesion failure and angina compared with metallic DES. FUNDING Abbott Vascular.
Collapse
Affiliation(s)
- Gregg W Stone
- NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, NY, USA; Clinical Trials Center, Cardiovascular Research Foundation, New York, NY, USA.
| | | | - Tommaso Gori
- Kardiologie I University Medical Center and Deutsches Zentrum für Herz-Kreislaufforschung, Rhein-Main, Mainz, Germany
| | | | | | | | | | | | - William Lawson
- Stony Brook University Medical Center, Stony Brook, NY, USA
| | - Thomas M Broderick
- The Carl and Edyth Lindner Research Center at The Christ Hospital, Cincinnati, OH, USA
| | - Ameer Kabour
- Mercy St Vincent Medical Center, Toledo, OH, USA
| | - Guy Piegari
- St Joseph Medical Center, Wyomissing, PA, USA
| | | | | | - James W Choi
- Baylor Jack and Jane Hamilton Heart and Vascular Hospital, Dallas, TX, USA
| | - Steven O Marx
- NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, NY, USA
| | - Philippe Généreux
- Clinical Trials Center, Cardiovascular Research Foundation, New York, NY, USA; Gagnon Cardiovascular Institute, Morristown Medical Center, Morristown, NJ, USA; Hôpital du Sacré-Coeur de Montréal, Montreal, QC, Canada
| | - Dean J Kereiakes
- The Carl and Edyth Lindner Research Center at The Christ Hospital, Cincinnati, OH, USA
| |
Collapse
|