1
|
El Sherbini AH, Servito M, Zidan A, Elsherif S, Ko G, Elgendy IY, Ya'Qoub L. Sex differences in the outcomes after transcatheter aortic valve replacement with newer generation devices: A meta-analysis. Catheter Cardiovasc Interv 2024; 103:808-814. [PMID: 38461377 DOI: 10.1002/ccd.30985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 01/21/2024] [Accepted: 02/11/2024] [Indexed: 03/11/2024]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is a reasonable therapeutic approach among patients with symptomatic severe aortic stenosis irrespective of surgical risk. Data regarding sex-specific differences in the outcomes with newer generation valves are limited. METHODS Electronic databases were searched for studies assessing sex differences in the outcomes of patients undergoing TAVR with newer generation valves (SAPIEN 3 or Evolut). Random effects model was constructed for summary estimates. RESULTS Four observational studies with 4522 patients (44.8% women) were included in the meta-analysis. Women were older and had a lower prevalence of coronary artery disease and mean EuroScore. Women had a higher incidence of short-term mortality (up to 30 days) (risk ratio [RR]: 1.60, 95% confidence interval [CI]: 1.14-2.25), but no difference in 1-year mortality (RR: 0.92, 95% CI: 0.72-1.17). There was no significant difference in the incidence of major bleeding (RR: 1.16, 95% CI: 0.86-1.57), permanent pacemaker (PPM) (RR: 0.80, 95% CI: 0.62-1.04), or disabling stroke (RR: 1.16, 95% CI: 0.54-2.45). CONCLUSION In this meta-analysis, we found that women undergoing TAVR with newer-generation devices were older but had a lower prevalence of comorbidities. Women had a higher incidence of short-term mortality but no difference in the 1-year mortality, bleeding, PPM, or stroke compared with men. Future studies are required to confirm these findings.
Collapse
Affiliation(s)
- Adham H El Sherbini
- Department of Internal Medicine Faculty of Health Sciences, Queen's University, Kingston, Ontario, Canada
| | - Maria Servito
- Division of Cardiac Surgery, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Ali Zidan
- Department of Internal Medicine Faculty of Health Sciences, Queen's University, Kingston, Ontario, Canada
| | - Salma Elsherif
- Department of Internal Medicine Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Grace Ko
- Department of Internal Medicine Faculty of Health Sciences, Queen's University, Kingston, Ontario, Canada
| | - Islam Y Elgendy
- Division of Cardiovascular Medicine, Gill Heart Institute, University of Kentucky, Lexington, Kentucky, USA
| | - Lina Ya'Qoub
- Division of Cardiovascular Medicine, University of California San Francisco, San Francisco, USA
| |
Collapse
|
2
|
Šolc AJ, Línková H, Toušek P. Transcatheter aortic valve durability, predictors of bioprosthetic valve dysfunction, longer-term outcomes - a review. Expert Rev Med Devices 2024; 21:15-26. [PMID: 38032186 DOI: 10.1080/17434440.2023.2288275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 11/22/2023] [Indexed: 12/01/2023]
Abstract
INTRODUCTION Transcatheter aortic valve implantation (TAVI) is one of the most significant inventions in cardiology, as it provides a viable minimally invasive treatment option for patients with aortic stenosis, the most common valvular disease in the developed world and one with a poor prognosis when left untreated. Using data available to date, this review aims to discuss and identify possible predictors of TAVI valve durability - an essential requirement for the device's wide-spread use, especially in younger patients. AREAS COVERED This article explores the main causes of bioprosthetic valve dysfunction (BVD) based on pathophysiology and available data, and reviews possible predictors of BVD including prosthesis-related, procedure-related, and patient-related factors. An emphasis is made on affectable predictors, which could potentially be targeted with prevention management and improve valve durability. A literature search of online medical databases was conducted using relevant key words and dates; significant clinical trials were identified. A brief overview of important randomized controlled trials with mid to long-term follow-up is included in this article. EXPERT OPINION Identifying modifiable predictors of valve dysfunction presents an opportunity to enhance and predict valve durability - a necessity as patients with longer life-expectancies are being considered for the procedure.
Collapse
Affiliation(s)
- Abigail Johanna Šolc
- Third Faculty of Medicine, Charles University, Prague, Czech Republic
- Department of Cardiology, University Hospital Kralovské Vinohrady, Prague, Czech Republic
| | - Hana Línková
- Third Faculty of Medicine, Charles University, Prague, Czech Republic
- Department of Cardiology, University Hospital Kralovské Vinohrady, Prague, Czech Republic
| | - Petr Toušek
- Department of Cardiology, Third Faculty of Medicine, University Hospital Královské Vinohrady, Charles University, Prague, Czech Republic
| |
Collapse
|
3
|
Al Nasef M, Saleem I, Salim A, Atiyah M, Al Najashi KS. Long-term Outcome of Simultaneous Transcatheter Pulmonary and Tricuspid Valve-in-Valve Implantation in Ebstein Malformation With Pulmonary Insufficiency. CJC PEDIATRIC AND CONGENITAL HEART DISEASE 2023; 2:206-209. [PMID: 37969859 PMCID: PMC10642148 DOI: 10.1016/j.cjcpc.2023.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 03/07/2023] [Indexed: 11/17/2023]
Affiliation(s)
- Mohamed Al Nasef
- Department of Pediatric Cardiology, Prince Sultan Cardiac Center (PSCC), Riyadh, Saudi Arabia
| | - Irfan Saleem
- Department of Pediatric Cardiology, Prince Sultan Cardiac Center (PSCC), Riyadh, Saudi Arabia
| | - Ahmad Salim
- Department of Pediatric Cardiology, Prince Sultan Cardiac Center (PSCC), Riyadh, Saudi Arabia
| | - Merna Atiyah
- Department of Pediatric Cardiology, Prince Sultan Cardiac Center (PSCC), Riyadh, Saudi Arabia
| | - Khalid S. Al Najashi
- Department of Pediatric Cardiology, Prince Sultan Cardiac Center (PSCC), Riyadh, Saudi Arabia
| |
Collapse
|
4
|
Sattar Y, Prakash P, Almas T, Mir T, Titus A, Ahmad S, Khan MS, Aggarwal A, Ullah W, Alhharbi A, Kakouros N, Alraies MC, Qureshi WT. Cardiovascular Outcomes of Older versus Newer Generation Transcatheter Aortic Valve Replacement Recipients: A Systematic Review & Meta-analysis. Curr Probl Cardiol 2023; 48:101467. [PMID: 36272548 DOI: 10.1016/j.cpcardiol.2022.101467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 10/13/2022] [Indexed: 01/04/2023]
Abstract
Newer generation transcatheter heart valves (THV) are presumed to yield better clinical efficacy and postprocedural complication profile as compared to transcatheter aortic valve replacement (TAVR) using older generation THVs. The real impact of newer generation valves on TAVR outcomes is not well known. Studies comparing older and newer generation THVs were identified from online databases including PubMed, EMBASE, Cochrane, and ClinicalTrials.gov from inception until August 2020. The primary outcome of the study was to compare mortality. Secondary outcomes included cerebrovascular events, myocardial infarction, major vascular complications, major bleeding, acute kidney injury, paravalvular leak, and post-procedural pacemaker implantation. Statistical analysis was performed using the Mantel-Haenszel random effect model with an odds ratio (OR), 95% confidence interval (CI), and p-value significance ≤0.05. A total of 14 studies were included with a combined patient population of 5697 patients (older generation n=1996; newer generation n=3701). Newer generation valves showed statistically significant results favoring lower major vascular complications (OR=2.05; 95% CI, 1.33-3.18; P = 0.00), major bleeding (OR=1.99; 95% CI, 1.35-2.93; P = 0.00), acute kidney injury (OR=1.71; 95% CI, 1.13-2.59; P = 0.01), paravalvular leak (OR=2.41; 95% CI, 1.11-5.28; P = 0.03) and mortality (OR=1.50; 95% CI, 1.10-2.06; P = 0.01) as compared to older generation valves. Cerebrovascular events, myocardial infarction, and pacemaker placement rates were found to be similar between older and newer generation valves. TAVR outcomes using newer generation valves are superior to those of older generation valves in terms of major vascular complications, acute kidney injury, paravalvular leak, and mortality.
Collapse
Affiliation(s)
- Yasar Sattar
- Department of Cardiology, West Virginia University, Morgantown, WV
| | - Preeya Prakash
- Department of Internal Medicine, Detroit Medical center, Wayne State University, Detroit, MI
| | - Talal Almas
- Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Tanveer Mir
- Department of Internal Medicine, Detroit Medical center, Wayne State University, Detroit, MI
| | - Anoop Titus
- Department of Internal Medicine, Saint Vincent Hospital, Worcester, MA
| | - Saad Ahmad
- Department of Internal Medicine, Icahn School of Medicine at Mount Sinai - Elmhurst Hospital, Queens, NY
| | | | - Ankita Aggarwal
- Department of Internal Medicine, Ascension providence Rochester
| | - Waqas Ullah
- Department of Internal Medicine, Abington Jefferson Health, Abington, PA
| | - Anas Alhharbi
- Department of Cardiology, West Virginia University, Morgantown, WV
| | - Nikolaos Kakouros
- Division of Cardiology, University of Massachusetts School of Medicine, Worcester, MA
| | - M Chadi Alraies
- Department of Interventional Cardiology, Detroit Medical Center, DMC Heart Hospital, Detroit, MI
| | - Waqas T Qureshi
- Division of Cardiology, University of Massachusetts School of Medicine, Worcester, MA.
| |
Collapse
|
5
|
Wilde N, Rogmann M, Mauri V, Piayda K, Schmitz MT, Al-Kassou B, Shamekhi J, Maier O, Sugiura A, Weber M, Zimmer S, Zeus T, Kelm M, Adam M, Baldus S, Nickenig G, Veulemans V, Sedaghat A. Haemodynamic differences between two generations of a balloon-expandable transcatheter heart valve. Heart 2022; 108:1479-1485. [PMID: 35039329 DOI: 10.1136/heartjnl-2021-320084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 12/07/2021] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVES This study aimed to investigate early haemodynamic and clinical performance of the SAPIEN 3 Ultra (S3 Ultra) transcatheter heart valve (THV) system in comparison to its precursor, the SAPIEN 3 (S3). Previous studies have indicated potential haemodynamic differences between the S3 Ultra and S3. Such differences may impact clinical outcome after transcatheter aortic valve implantation (TAVI). METHODS Postprocedural haemodynamic performance and 30-day clinical outcome were compared in patients who underwent TAVI receiving either the S3 or the new S3 Ultra prostheses. Multivariable analysis and propensity score matching (PSM) were used to identify factors associated with higher mean transvalvular gradients. RESULTS We included 697 patients (S3 Ultra: n=314, S3: n=383) from the multicentre RhineHeart TAVI Registry. Patients receiving the S3 Ultra prosthesis showed significantly higher postprocedural mean transvalvular gradients (14.2±4.8 vs 10.2±4.4 mm Hg; p<0.01). Multivariable logistic regression analyses and additional PSM revealed the use of the S3 Ultra to be associated with higher postprocedural mean transvalvular gradients (p<0.01). 30-day clinical outcomes, such as mortality, myocardial infarction, permanent pacemaker implantation and vascular complications were comparable between the groups. CONCLUSIONS The new S3 Ultra THV was associated with a higher postprocedural mean transvalvular gradient compared with the S3 system, while there was no difference in mortality or adverse clinical outcomes at 30 days. These echocardiographic differences will require long-term studies to assess the clinical relevance of this finding.
Collapse
Affiliation(s)
- Nihal Wilde
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Marc Rogmann
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Victor Mauri
- Heart Centre Cologne, Department of Cardiology, University Hospital Cologne, Cologne, Germany
| | - Kerstin Piayda
- Department of Cardiology, Pulmonology, and Angiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Marie-Therese Schmitz
- Department of Medical Biometry, Informatics and Epidemiology, University Hospital Bonn, Bonn, Germany
| | - Baravan Al-Kassou
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Jasmin Shamekhi
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Oliver Maier
- Department of Cardiology, Pulmonology, and Angiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Atsushi Sugiura
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Marcel Weber
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Sebastian Zimmer
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Tobias Zeus
- Department of Cardiology, Pulmonology, and Angiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Malte Kelm
- Department of Cardiology, Pulmonology, and Angiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Matti Adam
- Heart Centre Cologne, Department of Cardiology, University Hospital Cologne, Cologne, Germany
| | - Stephan Baldus
- Heart Centre Cologne, Department of Cardiology, University Hospital Cologne, Cologne, Germany
| | - Georg Nickenig
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| | - Verena Veulemans
- Department of Cardiology, Pulmonology, and Angiology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Alexander Sedaghat
- Heart Centre Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
6
|
Transcatheter Mitral Valve-in-Valve Implantation in Pediatric Patients. CJC Open 2022; 4:20-27. [PMID: 35072024 PMCID: PMC8767141 DOI: 10.1016/j.cjco.2021.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 08/22/2021] [Indexed: 11/23/2022] Open
Abstract
Background Methods Results Conclusions
Collapse
|
7
|
Akyüz AR, Konuş AH, Çırakoğlu ÖF, Şahin S, Kul S, Korkmaz L. First experiences with a new balloon-expandable Myval transcatheter aortic valve: a preliminary study. Herz 2021; 47:449-455. [PMID: 34643745 PMCID: PMC8512594 DOI: 10.1007/s00059-021-05069-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 08/02/2021] [Accepted: 09/12/2021] [Indexed: 10/25/2022]
Abstract
BACKGROUND In the present article, we present our first experiences with a new type of balloon-expandable Myval valve (Meril Life Sciences, Gujarat, India). MATERIALS AND METHODS A total of 25 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) from June 2020 to November 2020 were included in the study. RESULTS The mean age of the study population was 83 (75-87) years; 17 (68%) were female, and 20 (80%) had hypertension. The Society of Thoracic Surgeons (STS) score of the group was 5.4% ± 3.5%. TAVI was performed via the transfemoral route on all patients. In 19 (76%) cases, we started the procedure without predilation. In two (10.5%) cases performed without predilation, the prosthesis did not pass the native valve. We had to implant the valve from the descending aorta in one (4%) patient. We used Prostar XL (Abbott Vascular, Santa Clara, CA, USA) for six (24%) patients and ProGlide (Abbott Vascular) for 19 (76%) patients for vascular closure. Two (8%) in-hospital deaths occurred in our study but there were no deaths in the 30-day and 90-day follow-up. Vascular complications were observed in one (4%) patient. None of the patients in our study had severe paravalvular leak (PVL), while two (8%) patients had moderate PVL. A permanent pacemaker (PPM) was required in two (8%) patients for the indication of complete atrioventricular block. The mean hospital stay for the whole group was 4 (3-7) days. CONCLUSION Based on our experiences, the new balloon-expandable valve Myval is easy to use, efficient, and has only a few negligible drawbacks such as the need for predilation of the sheath. While shaft flexibility may have advantages in some situations including in very tortuous arteries, it may cause some difficulties in alignment of the valves.
Collapse
Affiliation(s)
- Ali Rıza Akyüz
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey.
| | - Ali Hakan Konuş
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey
| | - Ömer Faruk Çırakoğlu
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey
| | - Sinan Şahin
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey
| | - Selim Kul
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey
| | - Levent Korkmaz
- Ahi Evren Cardiovascular and Thoracic Surgery Training and Research Hospital, Department of Cardiology, University of Health Sciences, Trabzon, Turkey
| |
Collapse
|
8
|
Ullah W, Zahid S, Zaidi SR, Sarvepalli D, Haq S, Roomi S, Mukhtar M, Khan MA, Gowda SN, Ruggiero N, Vishnevsky A, Fischman DL. Predictors of Permanent Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement - A Systematic Review and Meta-Analysis. J Am Heart Assoc 2021; 10:e020906. [PMID: 34259045 PMCID: PMC8483489 DOI: 10.1161/jaha.121.020906] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Background As transcatheter aortic valve replacement (TAVR) technology expands to healthy and lower‐risk populations, the burden and predictors of procedure‐related complications including the need for permanent pacemaker (PPM) implantation needs to be identified. Methods and Results Digital databases were systematically searched to identify studies reporting the incidence of PPM implantation after TAVR. A random‐ and fixed‐effects model was used to calculate unadjusted odds ratios (OR) for all predictors. A total of 78 studies, recruiting 31 261 patients were included in the final analysis. Overall, 6212 patients required a PPM, with a mean of 18.9% PPM per study and net rate ranging from 0.16% to 51%. The pooled estimates on a random‐effects model indicated significantly higher odds of post‐TAVR PPM implantation for men (OR, 1.16; 95% CI, 1.04–1.28); for patients with baseline mobitz type‐1 second‐degree atrioventricular block (OR, 3.13; 95% CI, 1.64–5.93), left anterior hemiblock (OR, 1.43; 95% CI, 1.09–1.86), bifascicular block (OR, 2.59; 95% CI, 1.52–4.42), right bundle‐branch block (OR, 2.48; 95% CI, 2.17–2.83), and for periprocedural atriorventricular block (OR, 4.17; 95% CI, 2.69–6.46). The mechanically expandable valves had 1.44 (95% CI, 1.18–1.76), while self‐expandable valves had 1.93 (95% CI, 1.42–2.63) fold higher odds of PPM requirement compared with self‐expandable and balloon‐expandable valves, respectively. Conclusions Male sex, baseline atrioventricular conduction delays, intraprocedural atrioventricular block, and use of mechanically expandable and self‐expanding prosthesis served as positive predictors of PPM implantation in patients undergoing TAVR.
Collapse
Affiliation(s)
- Waqas Ullah
- Thomas Jefferson University Hospitals Philadelphia PA
| | | | | | | | | | | | - Maryam Mukhtar
- University Hospitals of Leicester NHS Trust Leicester UK
| | | | | | | | | | | |
Collapse
|
9
|
Fukuda H, Kiyohara K, Sato D, Kitamura T, Kodera S. A Real-World Comparison of 1-Year Survival and Expenditures for Transcatheter Aortic Valve Replacements: SAPIEN 3 Versus CoreValve Versus Evolut R. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2021; 24:497-504. [PMID: 33840427 DOI: 10.1016/j.jval.2020.10.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 07/30/2020] [Accepted: 10/23/2020] [Indexed: 06/12/2023]
Abstract
OBJECTIVES New versions of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement (TAVR) have been developed, but few studies have examined the outcomes associated with these devices using national-level data. This study aimed to elucidate the clinical and economic outcomes of TAVR for aortic stenosis in Japan through an analysis of real-world data. METHODS This retrospective cohort study was performed using data from patients with aortic stenosis who had undergone transfemoral TAVR with Edwards SAPIEN 3, Medtronic CoreValve, or Medtronic Evolut R valves throughout Japan from April 2016 to March 2018. Pacemaker implantation, mortality, and health expenditure were examined for each valve type during hospitalization and at 1 month, 3 months, 6 months, and 1 year. Generalized linear regression models and Cox proportional hazards models were used to examine the associations between the valve types and outcomes. RESULTS We analyzed 7244 TAVR cases (SAPIEN 3: 5276, CoreValve: 418, and Evolut R: 1550) across 145 hospitals. The adjusted 1-year expenditures for SAPIEN 3, CoreValve, and Evolut R were $79 402, $76 125, and $75 527, respectively; SAPIEN 3 was significantly more expensive than the other valves (P < .05). The pacemaker implantation hazard ratios (95% confidence intervals) for CoreValve and Evolut R were significantly higher (P < .001) than SAPIEN 3 at 2.61 (2.07-3.27) and 1.80 (1.53-2.12), respectively. The mortality hazard ratios (95% confidence intervals) for CoreValve and Evolut R were not significant at 1.11 (0.84-1.46) and 1.22 (0.97-1.54), respectively. CONCLUSIONS SAPIEN 3 users had generally lower pacemaker implantation and mortality but higher expenditures than CoreValve and Evolut R users.
Collapse
Affiliation(s)
- Haruhisa Fukuda
- Department of Health Care Administration and Management, Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan.
| | - Kosuke Kiyohara
- Department of Food Science, Otsuma Women's University, Tokyo, Japan
| | - Daisuke Sato
- Center for Next Generation of Community Health, Chiba University Hospital, Chiba, Japan
| | - Tetsuhisa Kitamura
- Division of Environmental Medicine and Population Sciences, Department of Social and Environmental Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Satoshi Kodera
- Department of Cardiovascular Medicine, The University of Tokyo Hospital, Tokyo, Japan
| |
Collapse
|
10
|
Ibanez I, de Azevedo Gomes BA, Nieckele AO. Effect of percutaneous aortic valve position on stress map in ascending aorta: A fluid-structure interaction analysis. Artif Organs 2021; 45:O195-O206. [PMID: 33326639 DOI: 10.1111/aor.13883] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 12/06/2020] [Accepted: 12/10/2020] [Indexed: 11/30/2022]
Abstract
Transcatheter aortic valve implantation (TAVI) is an increasingly widespread procedure. Although this intervention is indicated for high and low surgical risk patients, some issues still remain, such as prosthesis positioning optimization in the aortic annulus. Coaxial positioning of the percutaneous prosthesis influences directly on the aortic wall stress map. The determination of the mechanical stress that acts on the vascular endothelium resulting from blood flow can be considered an important task, since TAVI positioning can lead to unfavorable hemodynamic patterns, resulting in changes in parietal stress, such as those found in post-stenotic dilatation region. This research aims to investigate the influence of the prosthetic valve inclination angle in the mechanical stresses acting in the ascending aortic wall. Aortic compliance and blood flow during cardiac cycle were numerically obtained using fluid structure interaction. The aortic model was developed through segmentation of a computed tomography image of a specific patient submitted to TAVI. When compared to standard position (coaxiality match between the prosthesis and the aortic annulus), the inclination of 4° directed to the left main coronary artery decreased the aortic wall area with high values of wall shear stress and pressure. Coaxial positioning optimization of percutaneous aortic prosthesis may decrease the high mechanical stress area. These changes may be important to reduce the aortic remodeling process, vascular calcification or even the prosthesis half-life. Computational fluid dynamics makes room for personalized medicine, with manufactured prosthesis tailored to each patient.
Collapse
Affiliation(s)
- Ivan Ibanez
- Department of Mechanical Engineering, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Bruno A de Azevedo Gomes
- Department of Mechanical Engineering, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil.,Instituto Nacional de Cardiologia - MS, Rio de Janeiro, Brazil
| | - Angela O Nieckele
- Department of Mechanical Engineering, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
11
|
Evaluation of procedural and clinical outcomes of transcatheter aortic valve implantation: A single-center experience. Anatol J Cardiol 2021; 23:288-296. [PMID: 32352409 PMCID: PMC7219308 DOI: 10.14744/anatoljcardiol.2020.03942] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Objective: Transcatheter aortic valve implantation (TAVI) is an established alternative to surgical aortic valve replacement. Our study aimed to evaluate the implementation of TAVI at our large-volume center, having an all-comer patient population with short and long-term follow-ups. Methods: This retrospective, single-center analysis included 556 consecutive patients with symptomatic severe aortic stenosis (AS) who underwent TAVI between July 2011 and December 2019. Results: The mean age of the entire population was 77.6±7.9 years, and 54.9% were women. The Society of Thoracic Surgeons (STS) mean score of the cohort was 6.0%±3.5%. The balloon-expandable valve (Sapien XT, Sapien 3; Edwards Lifesciences, Irvine, California) was the most frequently used valves in this cohort (94.6%). Transfemoral access was used in 96.3% of patients. Implantation success was achieved in 96.6% of cases. During the TAVI procedure, 7.2% of patients required permanent pacemaker implantation, with 37.5% in the Lotus valve group needing the most permanent pacemakers. The mean length of hospital stay for the entire cohort was 4.5±2.3 days. Overall, 22 (3.9%) in-hospital deaths occurred before hospital discharge. The mean follow-up period was 15.1±14.9 months for all patients, and a significant improvement was noted in all echocardiographic parameters and functional capacity. Paravalvular leak (PVL) was documented in 18.9% patients, mild in 17.9%, and moderate in 1% at discharge. No cases with severe PVL, necessitating additional procedures. The multiple logistic regression analysis revealed that sex, STS score, baseline SYNTAX score, bicuspid valve morphology, common femoral artery diameter, and post-TAVI PVL were independent predictors of overall mortality. Conclusion: To our knowledge, this study, which is the largest single-center real-world experience of TAVI in Turkey, demonstrated low complication rates with favorable short- and mid-term THV performance in patients undergoing TAVI.
Collapse
|
12
|
Alperi A, Muntané-Carol G, Freitas-Ferraz AB, Junquera L, Del Val D, Faroux L, Philippon F, Rodés-Cabau J. Overcoming the transcatheter aortic valve replacement Achilles heel: conduction abnormalities-a systematic review. Ann Cardiothorac Surg 2020; 9:429-441. [PMID: 33312901 DOI: 10.21037/acs-2020-av-40] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Background Transcatheter aortic valve replacement (TAVR) has been shown to be a good alternative to surgery for treating severe symptomatic aortic stenosis (AS) across the whole range of surgical risk patients. Whereas most periprocedural TAVR complications have significantly decreased over time, conduction disturbances remain high. Approaches to decrease this shortcoming are under continuous investigation. Methods We conducted a systematic review focusing on modifiable factors impacting post-TAVR conduction disturbances, such as balloon aortic valvuloplasty (BAV), type of new-generation transcatheter valve and implantation depth (ID). Search strategies were based on the best available evidence from each study. Primary endpoints were post-TAVR need of permanent pacemaker implantation (PPI) and new onset left bundle branch block (NOLBBB). Results Data from 35 studies with a total of 29,982 patients were analyzed. BAV did not negatively impact PPI rates after TAVR. In propensity-matched and randomized trials, the Evolut R valve was associated with higher rates of PPI compared to the Sapien 3 valve (25% vs. 19.2% in propensity-matched studies; 22.9% vs. 19% in a randomized trial). The Acurate Neo valve was associated with the lowest PPI rate in observational studies (10.4%), but a PPI rate similar to Sapien 3 was reported in a randomized trial (10% vs. 9%). The Portico valve system was associated with a higher PPI risk (PPI rate of 21.9% and 27.7% in propensity-matched and randomized studies, respectively). ID and its relation with the membranous septum (MS) length predicted post-TAVR conduction disturbances, particularly with Evolut R and Sapien 3 valves. Conclusions Pre-TAVR BAV did not increase the risk of conduction disturbances post-TAVR. Among the new-generation transcatheter valve systems, Sapien 3 and Acurate Neo valves were associated with the lowest PPI rates followed by the Evolut and Portico valves. A deeper valve implantation and a shorter MS length determined an increased risk of conduction disturbances post-TAVR.
Collapse
Affiliation(s)
- Alberto Alperi
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | | | | | - Lucia Junquera
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - David Del Val
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Laurent Faroux
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - François Philippon
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Josep Rodés-Cabau
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| |
Collapse
|
13
|
Schymik G, Wendler O, Hengstenberg C, Ohlmann P, Gilard M, Digne F, Souteyrand G, Letocart V, van Belle E, Bramlage P, Tarantini G. Outcomes of transfemoral balloon expandable transcatheter aortic valve implantation: Comparison of two subsequent valve generations. Catheter Cardiovasc Interv 2020; 96:930-939. [PMID: 31794159 DOI: 10.1002/ccd.28621] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 10/28/2019] [Accepted: 11/11/2019] [Indexed: 01/20/2023]
Abstract
BACKGROUND The SAPIEN 3 (S3) addresses several limitations of the SAPIEN XT (SXT) for the performance of transfemoral (TF-) balloon expandable transcatheter aortic valve implantation (TAVI). OBJECTIVES We aimed to determine whether their altered features translate into improved outcomes in a real-world TF-TAVI patient population. METHODS Data for 3,314 patients were extracted from the European registries SOURCE-XT and SOURCE-3. Patients were propensity-score (PS) matched (n = 1,169/group). RESULTS In the PS matched comparison, device success was higher in the S3 (99.2%) compared to the SXT group (98.2%; p = .04). S3 patients experienced a lower rate of procedural death (0.7 vs. 2.6%; p = .0004), moderate/severe paravalvular leakage (PVL; 1.4 vs. 5.5%; p < .0001), and procedure-related stroke (1.2 vs. 2.4%; p = .04) while higher rates of mean aortic valve gradients ≥20 mmHg, and new permanent pacemaker implantations were seen. At 30 days a lower rate of all-cause mortality was seen (2.1% vs. 4.3%; p = .003), which was preserved after 1 year (10.7% vs. 14.9%; p = .002). A Cox regression predicting 1-year mortality resulted in a hazard ratio of 0.684 in favor of S3 (p = .0026). The same was true of stroke (2.8% vs. 5.7%; p = .0007), and moderate/severe PVL (2.7 vs. 7.3%; p = .0002) at 1 year. The rate of new pacemaker implantations (13.6% vs. 9.5%; p = .001) and NYHA III/IV (12.8 vs. 8.6%; p = .004) was higher with the S3. CONCLUSIONS The improved features of the S3 appear to translate into improved survival and reduced rates of adverse complications, with the exception of a higher rate of new pacemaker implantations.
Collapse
Affiliation(s)
| | | | - Christian Hengstenberg
- Klinische Abteilung für Kardiologie, Universitätsklinik für Innere Medizin II, Medizinische Universität Wien, Vienna, Austria
| | | | | | - Franck Digne
- Centre Cardiologique du Nord, Saint-Denis, France
| | | | | | | | - Peter Bramlage
- Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany
| | | | | |
Collapse
|
14
|
Alperi Garcia A, Muntané-Carol G, Junquera L, del Val D, Faroux L, Philippon F, Rodés-Cabau J. Can we reduce conduction disturbances following transcatheter aortic valve replacement? Expert Rev Med Devices 2020; 17:309-322. [DOI: 10.1080/17434440.2020.1741349] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
| | | | - Lucia Junquera
- Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada
| | - David del Val
- Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada
| | - Laurent Faroux
- Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada
| | - François Philippon
- Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada
| | - Josep Rodés-Cabau
- Quebec Heart & Lung Institute, Laval University, Quebec City, QC, Canada
| |
Collapse
|
15
|
Russo E, Potenza DR, Casella M, Massaro R, Russo G, Braccio M, Dello Russo A, Cassese M. Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status. Curr Cardiol Rev 2019; 15:205-218. [PMID: 30516109 PMCID: PMC6719385 DOI: 10.2174/1573403x15666181205105821] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 11/15/2018] [Accepted: 11/27/2018] [Indexed: 11/22/2022] Open
Abstract
Transcather aortic valve implantation (TAVI) has become a safe and indispensable treatment option for patients with severe symptomatic aortic stenosis who are at high surgical risk. Recently, outcomes after TAVI have improved significantly and TAVI has emerged as a qualified alternative to surgical aortic valve replacement in the treatment of intermediate risk patients and greater adoption of this procedure is to be expected in a wider patients population, including younger patients and low surgical risk patients. However since the aortic valve has close spatial proximity to the conduction system, conduction anomalies are frequently observed in TAVI. In this article, we aim to review the key aspects of pathophysiology, current incidence, predictors and clinical association of conduction anomalies following TAVI.
Collapse
Affiliation(s)
- Eleonora Russo
- Department of Cardiovascular Disease, Division of Cardiac Surgery, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy.,Department of Cardiovascular Disease, Division of Cardiology, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy
| | - Domenico R Potenza
- Department of Cardiovascular Disease, Division of Cardiology, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy
| | - Michela Casella
- Cardiac Arrhythmia Research Center, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Raimondo Massaro
- Department of Cardiovascular Disease, Division of Cardiology, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy
| | - Giulio Russo
- Institute of Cardiology, Catholic University of the Sacred Heart, Rome, Italy
| | - Maurizio Braccio
- Department of Cardiovascular Disease, Division of Cardiac Surgery, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy
| | - Antonio Dello Russo
- Cardiac Arrhythmia Research Center, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Mauro Cassese
- Department of Cardiovascular Disease, Division of Cardiac Surgery, Casa Sollievo della Sofferenza IRCCS, San Giovanni Rotondo, Italy
| |
Collapse
|
16
|
Rheude T, Blumenstein J, Möllmann H, Husser O. Spotlight on the SAPIEN 3 transcatheter heart valve. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2018; 11:353-360. [PMID: 30319292 PMCID: PMC6171512 DOI: 10.2147/mder.s143897] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVI) is increasingly performed in patients with severe aortic stenosis. The efficacy and safety have been demonstrated in large randomized trials in patients with high- or intermediate operative risk. With latest-generation transcatheter heart valve (THV) systems, growing operator experience and improved patient selection, clinical outcome has significantly improved with a decline of TAVI-related complications. In this review, the Edwards SAPIEN 3 THV is discussed in terms of technology, procedural advances and complication trends and future developments.
Collapse
Affiliation(s)
- Tobias Rheude
- Department of Cardiovascular Diseases, German Heart Centre, Technical University Munich, Munich, Germany
| | | | - Helge Möllmann
- Department of Cardiology, St.-Johannes-Hospital, Dortmund, Germany,
| | - Oliver Husser
- Department of Cardiology, St.-Johannes-Hospital, Dortmund, Germany,
| |
Collapse
|
17
|
Vendrik J, van Kesteren F, van Mourik MS, Piek JJ, Tijssen JG, Henriques JP, Wykrzykowska JJ, de Winter RJ, Driessen AH, Kaya A, Vis MM, Koch KT, Baan J. Procedural Outcome and Midterm Survival of Lower Risk Transfemoral Transcatheter Aortic Valve Implantation Patients Treated With the SAPIEN XT or SAPIEN 3 Device. Am J Cardiol 2018; 121:856-861. [PMID: 29415808 DOI: 10.1016/j.amjcard.2017.12.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 12/04/2017] [Accepted: 12/18/2017] [Indexed: 01/01/2023]
Abstract
Over the years increasing experience and technical device improvements in transcatheter aortic valve implantation (TAVI) have led to treatment of patients with lower surgical risks. Specifically for this population, device performance and longer term outcome are of great importance. In this single center, we performed a retrospective analysis of 515 consecutive patients with low- to intermediate surgical risk (STS-PROM ≤8), who underwent transfemoral TAVI between January 2009 and February 2017 with the SXT and ES3 prostheses, and we assessed procedural outcome and procedural and 3-year survival. Mean age (82 years in both groups, p = 0.344) and STS-PROM risk score (3.862 vs 3.992, p = 0.154) did not differ between the ES3 and SXT group. ES3-treated patients showed favorable procedural outcomes, with significantly higher device success (90% vs 73%, p <0.0001) and less paravalvular leakage (7% vs 13%, p <0.0001). Procedural mortality (0.87% vs 1.45%, p = 0.245) and the very low rate of permanent pacemaker implantations (7.4% vs 6.1%, p = 0.234) did not differ significantly. Three-year survival was 87% in the ES3 vs 80% in the SXT group (log-rank p = 0.385). In conclusion, we showed excellent survival and procedural outcomes in patients receiving a transfemoral TAVI with either the SAPIEN 3 or the SAPIEN XT device. The newer SAPIEN 3 even outperforms the SAPIEN XT in terms of less major bleeding complications, substantially higher device success rates, and less paravalvular leakage, with the permanent pacemaker implantation rate being very low in both groups. Survival curves show a nonsignificant trend toward better midterm survival in the ES3 group.
Collapse
|
18
|
van Rosendael PJ, Delgado V, Bax JJ. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J 2018; 39:2003-2013. [DOI: 10.1093/eurheartj/ehx785] [Citation(s) in RCA: 163] [Impact Index Per Article: 27.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 12/17/2017] [Indexed: 12/21/2022] Open
Affiliation(s)
- Philippe J van Rosendael
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| | - Victoria Delgado
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| | - Jeroen J Bax
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| |
Collapse
|
19
|
Comparison of 1-Year Survival and Frequency of Paravalvular Leakage Using the Sapien 3 Versus the Sapien XT for Transcatheter Aortic Valve Implantation for Aortic Stenosis. Am J Cardiol 2017; 120:2247-2255. [PMID: 29103606 DOI: 10.1016/j.amjcard.2017.08.049] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 08/18/2017] [Accepted: 08/22/2017] [Indexed: 11/21/2022]
Abstract
Transcatheter aortic valve implantation shortcomings such as relevant paravalvular leakage (PVL) have been shown to negatively impact survival. The Sapien 3 prosthesis has added features to address these problems. We compared the functional performance of the Sapien 3 (S3) and its predecessor Sapien XT (XT), with a particular focus on PVL. We analyzed 601 patients presenting with severe native aortic valve stenosis treated with either Sapien XT (n = 405, 2011 to 2014, mean STS-PROM [Society of Thoracic Surgeons predicted risk of mortality] 11.0%) or Sapien 3 prosthesis (n = 196, 2014 to 2016, mean STS-PROM 9.2%). Beside a propensity score-based comparison, we modeled the likelihood of PVL as a function of oversizing and prosthesis. Primary end points were 1-year survival, degree of oversizing, and occurrence of PVL. One-year survival (stratified log-rank p = 1.00) and 30-day mortality (S3: 10 of 126 vs XT: 10 of 126, p = 1.00) did not differ. In the matched cohort, oversizing was less common in the S3 group (absolute median difference of 7% in oversizing, interquartile range 1.1% to 12.7%, p = 0.025). PVL > = 1° was similar in both groups (S3: 13 of 126 vs XT: 20 of 126, p = 0.296). Mean gradients were lower in the XT group (median difference 1.0 mm Hg, interquartile range 0.3 to 1.8 mm Hg, p = 0.005). Rate of postdilatation, implantation of a second valve (valve-in-valve), annular rupture, and new pacemaker implantation were similar (all p = 1.00). In conclusion, compared with the Sapien XT, the redesigned Sapien 3 prosthesis offers effective sealing against PVL without grossly compromising hemodynamic performance or increasing the necessity for new pacemaker implantation.
Collapse
|
20
|
Choice of desflurane or propofol for the maintenance of general anesthesia does not affect the risk of periprocedural myocardial damage in patients undergoing transfemoral transcatheter aortic valve implantation. J Anesth 2017; 32:82-89. [DOI: 10.1007/s00540-017-2435-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 11/25/2017] [Indexed: 10/18/2022]
|
21
|
Tummala R, Banerjee K, Sankaramangalam K, Mick S, Krishnaswamy A, White J, Fares M, Mehta A, Popovic Z, Svensson LG, Kapadia SR. Clinical and procedural outcomes with the SAPIEN 3 versus the SAPIEN XT prosthetic valves in transcatheter aortic valve replacement: A systematic review and meta-analysis. Catheter Cardiovasc Interv 2017; 92:E149-E158. [DOI: 10.1002/ccd.27398] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 10/10/2017] [Indexed: 01/22/2023]
Affiliation(s)
- Ramyashree Tummala
- Department of Internal Medicine; St. Vincent Charity Medical Center, An Affiliate of Case Western Reserve University; Cleveland Ohio
| | - Kinjal Banerjee
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | | | - Stephanie Mick
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | | | - Jonathon White
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | - Maan Fares
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | - Anand Mehta
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | - Zoran Popovic
- Heart and Vascular Institute, Cleveland Clinic; Cleveland Ohio
| | | | | |
Collapse
|
22
|
Auffret V, Puri R, Urena M, Chamandi C, Rodriguez-Gabella T, Philippon F, Rodés-Cabau J. Conduction Disturbances After Transcatheter Aortic Valve Replacement. Circulation 2017; 136:1049-1069. [DOI: 10.1161/circulationaha.117.028352] [Citation(s) in RCA: 302] [Impact Index Per Article: 43.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) has become a well-accepted option for treating patients with aortic stenosis at intermediate to high or prohibitive surgical risk. TAVR-related conduction disturbances, mainly new-onset left bundle-branch block and advanced atrioventricular block requiring permanent pacemaker implantation, remain the most common complication of this procedure. Furthermore, improvements in TAVR technology, akin to the increasing experience of operators/centers, have translated to a major reduction in periprocedural complications, yet the incidence of conduction disturbances has remained relatively high, with perhaps an increasing trend over time. Several factors have been associated with a heightened risk of conduction disturbances and permanent pacemaker implantation after TAVR, with prior right bundle-branch block and transcatheter valve type and implantation depth being the most commonly reported. New-onset left bundle-branch block and the need for permanent pacemaker implantation may have a significant detrimental association with patients’ prognosis. Consequently, strategies intended to reduce the risk and to improve the management of such complications are of paramount importance, particularly in an era when TAVR expansion toward treating lower-risk patients is considered inevitable. In this article, we review the available evidence on the incidence, predictive factors, and clinical association of conduction disturbances after TAVR and propose a strategy for the management of these complications.
Collapse
Affiliation(s)
- Vincent Auffret
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - Rishi Puri
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - Marina Urena
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - Chekrallah Chamandi
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - Tania Rodriguez-Gabella
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - François Philippon
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| | - Josep Rodés-Cabau
- From University Hospital Pontchaillou, Cardiology and Vascular Disease Department, CIC-IT 804, Rennes 1 University, Signal and Image Processing Laboratory (LTSI), INSERM U1099, France (V.A.); Quebec Heart and Lung Institute, Laval University, Quebec City, Canada (V.A., R.P., C.C., T.R.-G., F.P., J.R.,-C.); and Bichat-Claude Bernard University Hospital, Paris, France (M.U.)
| |
Collapse
|