1
|
Gimeno-Morales M, Martínez-Monge R, Martinez-Lage A, Jablonska PA, Blanco J, Martínez-Regueira F, Rodriguez-Spiteri N, Olartecoechea B, Ramos L, Insausti LP, Elizalde A, Abengozar M, Cambeiro M. Long-term results of intraoperative multicatheter breast implant (IOMBI) for accelerated partial breast irradiation (APBI) on early breast cancer patients. Radiother Oncol 2024; 194:110193. [PMID: 38432310 DOI: 10.1016/j.radonc.2024.110193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 02/12/2024] [Accepted: 02/24/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND AND PURPOSE Multicatheter breast brachytherapy is a standard technique for accelerated partial breast irradiation (APBI) in early breast cancer patients. Intraoperative multicatheter breast implant (IOMBI) followed by perioperative high-dose-rate brachytherapy (PHDRBT) offers a novel and advantageous approach. We present long-term oncological, toxicity, and cosmesis outcomes for a well-experienced single institution. MATERIALS AND METHODS Eligible women aged ≥ 40 years with clinically and radiologically confirmed unifocal invasive or in situ ≤ 3 cm breast tumors underwent IOMBI during breast-conserving surgery. Patients meeting APBI criteria by definitive pathologic results received 3.4 Gy × 10fx with PHDRBT. Patients not suitable for APBI received PHDRBT-boost followed by WBRT. RESULTS A total of 171 patients underwent IOMBI during BCS, 120 patients (70.1 %) were suitable for APBI and 51 (29.8 %) for anticipated PHDRBT-boost. The median age was 61 years (range: 40-78), the median tumor size was 1.1 cm (range: 0.2-3.5), with a histological diagnosis of invasive ductal carcinoma in 78.9 % and ductal in situ in 21.1 %. A median of 9 catheters (range: 4-14) were used. For APBI, the median CTV and V100 were 40.8 cc (range: 8.6-99) and 35.4 cc (range: 7.2-94). The median of healthy breast tissue irradiated represents 7.2 % (range: 2.3-28 %) and the median local treatment duration was 10 days (range: 7-16). With a median follow-up of 8.8 years (range: 0.3-16.25), the 8-year local, locoregional, and distant control rates were 99 %, 98.1 %, and 100 %. G1-G2 late-toxicity rate was 53.4 %. Long-term cosmetic evaluation was excellent-good in 90.8 %. CONCLUSION IOMBI&PHDRBT program reports excellent long-term oncological outcomes, with a reduction from unnecessary irradiation exposure which translates into low long-term toxicity and good cosmesis outcomes, especially on well-selected APBI patients.
Collapse
Affiliation(s)
- Marta Gimeno-Morales
- Departments of Radiation Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain.
| | - Rafael Martínez-Monge
- Departments of Radiation Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Adriana Martinez-Lage
- Departments of Radiation Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Paola Anna Jablonska
- Departments of Radiation Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Javier Blanco
- Medical Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Fernando Martínez-Regueira
- Breast Surgical Oncology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Natalia Rodriguez-Spiteri
- Breast Surgical Oncology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Begoña Olartecoechea
- Breast Surgical Oncology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Luis Ramos
- Departament of Medical Physic, Hospital Arnau de Villanova, Lleida, Spain
| | - Luis Pina Insausti
- Radiology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Arlette Elizalde
- Radiology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Marta Abengozar
- Pathology Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| | - Mauricio Cambeiro
- Departments of Radiation Oncology, Cancer Center Clinica Universidad de Navarra. University of Navarre. Pamplona-Madrid, Spain
| |
Collapse
|
2
|
Four-fraction ultra-accelerated minimal breast irradiation in early breast cancer: The initial feasibility results of an institutional experience. Brachytherapy 2022; 21:475-486. [PMID: 35396137 DOI: 10.1016/j.brachy.2022.01.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 01/27/2022] [Accepted: 01/28/2022] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the feasibility, early toxicity, and clinical outcomes of early-breast cancer patients in a single-arm, phase I/II study of an ultra-accelerated, four-fraction schedule of minimal breast irradiation (4f-AMBI) using a multicatheter, minimally-invasive, intraoperative tumor bed implant (MITBI) during breast-conserving surgery (BCS). METHODS AND MATERIALS Eligible women aged >40 years with clinically and radiologically confirmed, unifocal invasive or in situ ≤3 cm tumors were considered as potential candidates for MITBI during BCS. After the pathology report, patients who met APBI criteria received ultra-accelerated four-fractions irradiation (6.2 Gy BID x 4fx over 2 days) with perioperative HDR-brachytherapy (PHDRBT). Early complications, toxicity, clinical outcomes, and cosmetic results were analyzed. RESULTS Of 89 patients initially implanted, 60(67.4%) were definitively included in the 4f-AMBI-protocol. The median age was 64.4 years; the median CTV was 32.1 cc (6.9-75.4 cc), and the external-V100 was 43.1 cc (12.87-107 cc), representing 5% of the breast tissue irradiated with a median CTV D90 of 6.2 Gy (5.6-6.28 Gy). The entire local treatment (BCS&MITBI-4f-AMBI) was completed at a median of 8 days (4-10 days). The rate of early complications was 11%. There were no major complications. Acute skin-subcutaneous G1 toxicity was reported in 11.7%, and late G1 toxicity on 36.7%. After a median follow-up of 27 months (11-51 months), the local, elsewhere, locoregional and distant-control rates were 100%, 98.3%, 100%, and 100% respectively. The early-cosmetic evaluation was excellent-good in 94.5% of patients evaluated. CONCLUSIONS Ultra-accelerated, four-fraction, minimal breast irradiation (4f-AMBI) using a minimally-invasive tumor bed implant procedure is safe, dosimetrically feasible, and shows small irradiated volumes. This program provides low toxicity rates and excellent short-term clinical and cosmesis outcomes.
Collapse
|
3
|
Brachytherapy in Breast Cancer. Pract Radiat Oncol 2020. [DOI: 10.1007/978-981-15-0073-2_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
4
|
Advantages of intraoperative implant for interstitial brachytherapy for accelerated partial breast irradiation either frail patients with early-stage disease or in locally recurrent breast cancer. J Contemp Brachytherapy 2018; 10:97-104. [PMID: 29789758 PMCID: PMC5961524 DOI: 10.5114/jcb.2018.75594] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 03/13/2018] [Indexed: 11/17/2022] Open
Abstract
Purpose To describe the intraoperative multicatheter implantation technique for accelerated partial breast irradiation (APBI) delivered with high-dose-rate brachytherapy (HDR-BT). Secondarily, to evaluate outcomes and toxicity in a series of 83 patients treated with this technique at our institution. Material and methods Retrospective analysis of a series of patients treated with HDR-BT APBI after intraoperative multicatheter interstitial implant between November 2006 and June 2017 at our institution. We assessed cosmesis, toxicity, overall survival (OS), and disease-free survival (DFS). Results Eighty-three patients were included: 59 patients (71.1%) with primary early-stage breast cancer and 24 (28.9%) with locally recurrent breast cancer. Tumorectomy was performed in all cases, with intraoperative tumor margin assessment and sentinel node biopsy. Median age was 82 years (range, 44-92). The total prescribed dose was 32 Gy (8 treatment fractions) in 60 patients (72.3%), and 34 Gy (10 fractions) in 23 patients (27.7%). Median follow-up was 40 months (range, 1-136 months). Three-year OS and DFS in the recurrent and primary cancer groups were 87% vs. 89%, and 96 % vs. 97.8%, respectively. Five patients died from non-cancer related causes. No local relapses were observed. Rates of acute and late toxicity were low in both groups. The cosmesis was good or excellent in most of patients treated for primary disease; in patients who underwent salvage brachytherapy for local recurrence, cosmesis was good in 49 patients and fair in 6. Conclusions This technique, although time-consuming, achieves good local disease control with a satisfactory toxicity profile in both early-stage and local recurrent breast cancer patients. It may be especially suitable for frail patients.
Collapse
|
5
|
Accelerated partial breast irradiation in a single 18 Gy fraction with high-dose-rate brachytherapy: preliminary results. J Contemp Brachytherapy 2018; 10:58-63. [PMID: 29619057 PMCID: PMC5881592 DOI: 10.5114/jcb.2018.73994] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Accepted: 01/22/2018] [Indexed: 11/17/2022] Open
Abstract
Purpose To evaluate the feasibility of acute and chronic toxicity in patients suitable for accelerated partial breast irradiation (APBI) in a single 18 Gy fraction with multicatheter high-dose-rate (HDR) brachytherapy, as well as cosmetic and oncological outcomes. Material and methods Between September 2014 and March 2016, twenty consecutive patients with low-risk invasive and ductal carcinoma in situ were treated with interstitial multicatheter HDR brachytherapy in a single 18 Gy fraction. Results Median age was 63.5 years (range, 51-79). Acute toxicity was observed in seven patients, while the pain during following days and hematoma were seen in four patients. With a median follow-up of 24 months, late toxicity was found in one patient with fat necrosis g2 and fibrosis g2 in another patient. The overall survival (OS) and locoregional control (LC) was 100%. Disease-free survival (DFS) and distant control was 95%. Good to excellent cosmetic outcomes were noted in 80% of patients and fair in 4 patients (20%). Conclusions This is the first report in the medical literature that focuses on feasibility and acute and chronic toxicity, with a median follow-up of 24 months (range, 20-40). The protocol is viable and convenient. However, a longer follow-up is needed to know chronic toxicity and oncologic outcomes.
Collapse
|
6
|
Should molecular subtype be recommended as one of the selection criteria for accelerated partial breast irradiation? Preliminary results from an Asian cohort. J Contemp Brachytherapy 2018; 10:47-57. [PMID: 29619056 PMCID: PMC5881594 DOI: 10.5114/jcb.2018.74137] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2017] [Accepted: 01/22/2018] [Indexed: 12/04/2022] Open
Abstract
Purpose The purpose of this study was to report clinical outcomes in patients treated with accelerated partial breast irradiation (APBI), stratified as per molecular subtype and American Society for Therapeutic Radiology and Oncology/Groupe Européen de Curiethérapie and European Society for Radiotherapy & Oncology (ASTRO/GEC-ESTRO) patient selection criteria in order to determine whether molecular subtype should be recommended as one of the selection criteria for APBI. Material and methods 157 early-stage breast cancers patients, treated with APBI using multi-catheter interstitial brachytherapy with ≥ 6 months follow-up were included. Molecular subtype was assigned based on estrogen/progesterone receptor (ER/PR), Her2neu and tumor grade. Patients were stratified into ASTRO and GEC-ESTRO risk groups, as per updated ASTRO consensus statement (CS) and GEC-ESTRO recommendation, respectively. The Kaplan-Meier method was used to calculate the time to event data of clinical outcomes. Results With a median follow-up of 35 months, local control (LC) and locoregional control (LRC) were not significantly different among the different molecular subtypes (p = 0.19, p = 0.41, respectively). None of the APBI guidelines predicted risk of local or locoregional recurrence. Re-analyzing the data by replacing ER status with molecular subtype in the ASTRO-CS did not show any significant difference in LC/LRC across the various categories. Her2neu subtype was associated with significantly lower disease-free survival, cause specific survival, and overall survival than the luminal subtypes. Conclusions None of the mentioned APBI guidelines predicted local or locoregional recurrence risk in our study population. Additional follow-up will be needed to recommend inclusion of molecular subtype (or at least HER2 receptor status) in the patient selection criteria for APBI.
Collapse
|
7
|
Gabani P, Cyr AE, Zoberi JE, Ochoa LL, Matesa MA, Thomas MA, Garcia J, Margenthaler JA, Naughton MJ, Ma C, Sanati S, Zoberi I. Long-term outcomes of APBI via multicatheter interstitial HDR brachytherapy: Results of a prospective single-institutional registry. Brachytherapy 2018; 17:171-180. [DOI: 10.1016/j.brachy.2017.09.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Revised: 09/19/2017] [Accepted: 09/19/2017] [Indexed: 10/18/2022]
|
8
|
Götz TI, Lahmer G, Brandt T, Kallis K, Strnad V, Bert C, Hensel B, Tomé AM, Lang EW. On the use of particle filters for electromagnetic tracking in high dose rate brachytherapy. Phys Med Biol 2017; 62:7617-7640. [PMID: 28796645 DOI: 10.1088/1361-6560/aa8591] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Modern radiotherapy of female breast cancers often employs high dose rate brachytherapy, where a radioactive source is moved inside catheters, implanted in the female breast, according to a prescribed treatment plan. Source localization relative to the patient's anatomy is determined with solenoid sensors whose spatial positions are measured with an electromagnetic tracking system. Precise sensor dwell position determination is of utmost importance to assure irradiation of the cancerous tissue according to the treatment plan. We present a hybrid data analysis system which combines multi-dimensional scaling with particle filters to precisely determine sensor dwell positions in the catheters during subsequent radiation treatment sessions. Both techniques are complemented with empirical mode decomposition for the removal of superimposed breathing artifacts. We show that the hybrid model robustly and reliably determines the spatial positions of all catheters used during the treatment and precisely determines any deviations of actual sensor dwell positions from the treatment plan. The hybrid system only relies on sensor positions measured with an EMT system and relates them to the spatial positions of the implanted catheters as initially determined with a computed x-ray tomography.
Collapse
Affiliation(s)
- Th I Götz
- CIML, Biophysics, University of Regensburg, 93040 Regensburg, Germany. Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
High-dose-rate interstitial brachytherapy for accelerated partial breast irradiation - trial results of Azerbaijan National Center of Oncology. J Contemp Brachytherapy 2017; 9:106-111. [PMID: 28533797 PMCID: PMC5437082 DOI: 10.5114/jcb.2017.67145] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Accepted: 03/11/2017] [Indexed: 01/30/2023] Open
Abstract
Purpose To describe early results of two cohorts of patients with low and intermediate risk of early breast cancer treated with accelerated partial breast irradiation (APBI) using different schedules of multicatheter brachytherapy. Material and methods Patients with early stage breast cancer after breast conserving surgery were enrolled for a prospective analysis. The APBI, using multicatheter brachytherapy, was delivered either eight times 4 Gy in five days with a planned total dose of 32 Gy, or seven times 5 Gy in four days with a planned total dose of 35 Gy. Primary endpoints were side effects. Results Forty-eight patients were enrolled between 2012 and 2014. Patients characteristics were as follow: median age of patients was 55 years, early breast cancer was defined according GEC-ESTRO recommendations. With a median follow-up period of 37 months, no significant differences regarding late side effects and cosmesis between two cohorts of patients were documented. In total, cosmesis was excellent in 13/48 (27.1%) patients, good in 34/48 (70.8%) patients, and moderate in 1/48 patient (2.1%). Conclusions Accelerated partial breast irradiation using multicatheter brachytherapy with 32 Gy/8 fractions and 35 Gy/7 fractions for early breast cancer seems to be similar in terms of late side effects. According to our findings, APBI was also feasible for intermediate-risk of early breast cancer patients.
Collapse
|
10
|
Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant. J Contemp Brachytherapy 2017; 9:139-145. [PMID: 28533802 PMCID: PMC5437076 DOI: 10.5114/jcb.2017.66027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 01/09/2017] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CIcommon, and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (Vmax/Vmin) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. Results The mean ± SD CIcommon of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and Vmax/Vmin decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CIcommon of V100% was 0.75 ± 0.11. The mean observed Vmax/Vmin of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. Conclusions Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.
Collapse
|
11
|
Major T, Polgár C. Treatment planning for multicatheter interstitial brachytherapy of breast cancer - from Paris system to anatomy-based inverse planning. J Contemp Brachytherapy 2017; 9:89-98. [PMID: 28344609 PMCID: PMC5346613 DOI: 10.5114/jcb.2017.66111] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 02/10/2017] [Indexed: 11/22/2022] Open
Abstract
In the last decades, treatment planning for multicatheter interstitial breast brachytherapy has evolved considerably from fluoroscopy-based 2D to anatomy-based 3D planning. To plan the right positions of the catheters, ultrasound or computed tomography (CT) imaging can be used, but the treatment plan is always based on postimplant CT images. With CT imaging, the 3D target volume can be defined more precisely and delineation of the organs at risk volumes is also possible. Consequently, parameters calculated from dose-volume histogram can be used for quantitative plan evaluation. The catheter reconstruction is also easier and faster on CT images compared to X-ray films. In high dose rate brachytherapy, using a stepping source, a number of forward dose optimization methods (manual, geometrical, on dose points, graphical) are available to shape the dose distribution to the target volume, and these influence dose homogeneities to different extent. Currently, inverse optimization algorithms offer new possibilities to improve dose distributions further considering the requirements for dose coverage, dose homogeneity, and dose to organs at risk simultaneously and automatically. In this article, the evolvement of treatment planning for interstitial breast implants is reviewed, different forward optimization methods are discussed, and dose-volume parameters used for quantitative plan evaluation are described. Finally, some questions of the inverse optimization method are investigated and initial experiences of the authors are presented.
Collapse
Affiliation(s)
- Tibor Major
- Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| | - Csaba Polgár
- Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| |
Collapse
|
12
|
Whole breast irradiation vs. APBI using multicatheter brachytherapy in early breast cancer - simulation of treatment costs based on phase 3 trial data. J Contemp Brachytherapy 2016; 8:505-511. [PMID: 28115956 PMCID: PMC5241384 DOI: 10.5114/jcb.2016.64919] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 12/19/2016] [Indexed: 11/17/2022] Open
Abstract
PURPOSE A recent large phase 3 trial demonstrated that the efficacy of accelerated partial-breast irradiation (APBI) in the treatment of early breast cancer is non-inferior to that of whole breast irradiation (WBI) commonly used in this indication. The aim of this study was to compare the costs of treatment with APBI and WBI in a population of patients after conserving surgery for early breast cancer, and to verify if the use of APBI can result in direct savings of a public payer. MATERIAL AND METHODS The hereby presented cost analysis was based on the results of GEC-ESTRO trial. Expenditures for identified cost centers were estimated on the basis of reimbursement data for the public payer. After determining the average cost of early breast cancer treatment with APBI and WBI over a 5-year period, the variance in this parameter resulting from fluctuations in the price per single procedure was examined on univariate sensitivity analysis. Then, incremental cost-effectiveness ratio (ICER) was calculated to verify the cost against clinical outcome. Finally, a simulation of public payer's expenditures for the treatment of early breast cancer with APBI and WBI in 2013 and 2025 has been conducted. RESULTS The average cost of treatment with APBI is lower than for WBI, even assuming a potential increase in the unit price of the former procedure. There was no additional health benefit of WBI and the calculation of cost-effectiveness was based on the absolute difference in overall local control rate. However, this difference (0.92% vs. 1.44%) was fairly minimal and was not identified as statistically significant during 5 years. CONCLUSIONS The use of APBI as an alternative to WBI in the treatment of early breast cancer would substantially reduce healthcare expenditures in both 2013 and 2025, even assuming an increase in the price per single APBI procedure.
Collapse
|
13
|
Akhtari M, Abboud M, Szeja S, Pino R, Lewis GD, Bass BL, Miltenburg DM, Butler EB, Teh BS. Clinical outcomes, toxicity, and cosmesis in breast cancer patients with close skin spacing treated with accelerated partial breast irradiation (APBI) using multi-lumen/catheter applicators. J Contemp Brachytherapy 2016; 8:497-504. [PMID: 28115955 PMCID: PMC5241383 DOI: 10.5114/jcb.2016.64830] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 12/07/2016] [Indexed: 11/20/2022] Open
Abstract
PURPOSE Accelerated partial breast irradiation (APBI) using a single-lumen device is associated with better cosmetic outcomes if the spacing between the applicator and skin is > 7 mm. However, there are no reports addressing the late toxicity and clinical outcomes in patients treated with single-entry multi-lumen/catheter applicators who had close skin spacing (7 mm or less). We undertook this study to report clinical outcome, acute and late toxicity as well as cosmesis of early stage breast cancer patients with close skin spacing treated with APBI using multi-lumen or multi-catheter devices. MATERIAL AND METHODS This is a retrospective study of all breast cancer patients who had undergone APBI using single-entry multi-lumen/catheter devices in a single institution between 2008 to 2012. The study was limited to those with ≤ 7 mm spacing between the device and skin. RESULTS We identified 37 patients and 38 lesions with skin spacing of ≤ 7 mm. Seven lesions (18%) had spacing of ≤ 3 mm. Median follow-up was 47.5 months. There was one case of ipsilateral breast recurrence and one ipsilateral axillary recurrence. Based on RTOG criteria, 22 treated lesions experienced grade 1 and 9 lesions experienced grade 2 toxicity. Twenty-one lesions experienced late grade 1 toxicity. One patient had to undergo mastectomy due to mastitis. Twenty-four treated breasts showed excellent and 11 had good cosmetic outcome. Overall cosmesis trended towards a significant correlation with skin spacing. However, all patients with ≤ 3 mm skin spacing experienced acute and late toxicities. CONCLUSIONS Accelerated partial breast irradiation can be safely performed in patients with skin spacing of ≤ 7 mm using single-entry multi-lumen/catheter applicators with excellent cosmetic outcomes and an acceptable toxicity profile. However, skin spacing of ≤ 3 mm is associated with acute and late toxicity and should be avoided if possible.
Collapse
Affiliation(s)
- Mani Akhtari
- Department of Radiation Oncology, University of Texas Medical Branch, Galveston, TX
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Mirna Abboud
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Sean Szeja
- Department of Radiation Oncology, University of Texas Medical Branch, Galveston, TX
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Ramiro Pino
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Gary D. Lewis
- Department of Radiation Oncology, University of Texas Medical Branch, Galveston, TX
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Barbara L. Bass
- Department of Surgery, Houston Methodist Hospital, Houston, TX
| | | | - E. Brian Butler
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| | - Bin S. Teh
- Department of Radiation Oncology, Houston Methodist Hospital, Cancer Center and Research Institute, Houston, TX
| |
Collapse
|
14
|
Shah C, Tendulkar R, Smile T, Nanavati A, Manyam B, Balagamwala E, Pham Y, Takiar R, Wobb J, Khan A, Arthur D, Wazer D, Vicini F. Adjuvant Radiotherapy in Early-Stage Breast Cancer: Evidence-Based Options. Ann Surg Oncol 2016; 23:3880-3890. [DOI: 10.1245/s10434-016-5503-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Indexed: 01/22/2023]
|