1
|
Cao MC, Jia RF, Wang YF, Pan KL, Hu J. The effects of health education and exercise style changes on the maturation of autologous arteriovenous fistula in hemodialysis patients: A randomized controlled trial. J Vasc Access 2025; 26:271-279. [PMID: 38053247 DOI: 10.1177/11297298231214572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023] Open
Abstract
BACKGROUND Upper limb exercise has long been considered to be the main means to promote autogenous arteriovenous fistula (AVF) maturation, but in practice exercise intensity and compliance are both typically lacking. Several randomized controlled trials (RCTs) have demonstrated the good effects of functional resistance or pressure exercise in patients with AVF. However, many patients' have difficulty complying with upper limb exercise programs without systematic health education. Therefore, we argue that resistance and pressure exercise supported by health education is actually the most beneficial for AVF patients. METHODS We randomly divided 114 patients into a control group and an experimental group of 57 patients each. In the control group, conventional care was used, and in the experimental group, online health education based on the IMB (Information-Motivation-Behavior skills) model and functional resistance and pressure upper limb exercises was implemented with the AVF side arm. The failure rate of AVF maturation, clinical maturation time, cephalic venous blood flow, vessel diameter, and vessel skin thickness were compared between the two groups. RESULTS Fifty-five cases were included for each in the final study. The primary outcome of this study was the failure rate of AVF maturation. Secondary outcomes included clinical maturation time, cephalic vein flow, vessel diameter, and vessel thickness. The failure rate of AVF maturation in the experimental group was significantly lower than that in the control group, and the clinical maturation time in the experimental group was significantly shorter than that in the control group. For the remaining three indicators, there were between-group effects, time effects, and interaction effects in both groups. Comparison between groups showed that there was no statistical difference in the observed indicators of cephalic vein flow, vessel diameter, or vessel thickness between the two groups before the intervention but that there was a statistical difference at the end of the 4th, 8th, and 12th weeks of the intervention. A 2 × 2 comparison also showed that there was a statistical difference between the three indicators at each time point within the two groups. CONCLUSION IMB model-based online health education combined with functional resistance and pressure exercises can improve AVF maturation status and accelerate AVF maturation within 12 weeks of surgery.
Collapse
Affiliation(s)
- Ming-Cong Cao
- Blood Purification Room of Cangzhou Central Hospital, Cangzhou, China
| | - Ru-Fu Jia
- Brain Department District Office, Cangzhou Central Hospital, Cangzhou, China
| | - Ya-Fei Wang
- Nursing Office of Cangzhou Central Hospital, Cangzhou, China
| | - Ke-Li Pan
- Nursing Office of Cangzhou Central Hospital, Cangzhou, China
| | - Jing Hu
- Blood Purification Room of Cangzhou Central Hospital, Cangzhou, China
| |
Collapse
|
2
|
Leong FF, Lee WC, Ng HY, Kuo PY, Lee CT, Fu CM. The Role of Duplex Ultrasound and Flow/Pressure Ratio in Predicting Invasive Treatment for High Venous Pressure in Patients Undergoing Hemodialysis. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:2055. [PMID: 39768934 PMCID: PMC11678677 DOI: 10.3390/medicina60122055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2024] [Revised: 12/05/2024] [Accepted: 12/10/2024] [Indexed: 01/11/2025]
Abstract
Background and Objectives: Vascular access complications, particularly high venous pressure, pose significant challenges for hemodialysis patients undergoing hemodialysis. Limited research has focused on identifying predictive factors for invasive treatment. This study aimed to identify patients who might benefit from frequent monitoring and conservative management based on duplex ultrasound (DUS) evaluation. Materials and Methods: This retrospective study included 72 hemodialysis patients with high venous pressure who underwent DUS. Patients were divided into conservative (n = 26) and invasive treatment groups (n = 46). Key factors such as flow/pressure ratio, blood flow, and venous pressure were analyzed. Logistic regression was used to identify risk factors for invasive treatment, while receiver operating characteristic (ROC) analysis was performed to establish the optimal cutoff for the flow/pressure ratio. Results: Three months after the DUS, 3.85% of the conservative group experienced access failure, compared to 71.7% in the invasive group. The flow/pressure ratio was significantly lower in the invasive group (1.28 ± 0.26 vs. 1.47 ± 0.23, p < 0.05). A higher flow/pressure ratio (OR: 0.063, 95% CI: 0.004-0.932, p = 0.044) and the presence of tortuous veins (OR: 0.080, 95% CI: 0.007-0.897, p = 0.0405) were associated with a lower risk of invasive treatment. ROC analysis showed a flow/pressure ratio cutoff of 1.38 (AUC: 0.706, p = 0.004). Conclusions: Duplex ultrasound plays a crucial role in evaluating arterio-venous access in patients with high venous pressure. It provides a non-invasive assessment of vascular complications, helping avoid unnecessary invasive procedures. The flow/pressure ratio is significantly associated with the risk of invasive treatment, providing a valuable threshold for assessing risk and guiding clinical decision-making to optimize treatment strategies.
Collapse
Affiliation(s)
- Foong-Fah Leong
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
| | - Wen-Chin Lee
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
| | - Hwee-Yeong Ng
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
| | - Po-Yen Kuo
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
| | - Chien-Te Lee
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Municipal Feng-Shan Hospital (Under Management of Chang Gung Medical Foundation), Kaohsiung 83062, Taiwan
| | - Chung-Ming Fu
- Division of Nephrology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung 833401, Taiwan
| |
Collapse
|
3
|
Spiliopoulos S, Filippou P, Giannikouris IE, Katsanos K, Palialexis K, Grigoriadis S, Kitrou P, Brountzos E, Karnabatidis D. US Volume Flow Assessment to Optimize Angioplasty of Dysfunctional Dialysis Access: The VOLA-II Multicenter Study. Radiology 2024; 313:e233076. [PMID: 39589250 DOI: 10.1148/radiol.233076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2024]
Abstract
Background Digital subtraction angiography and thrill palpation demonstrate limitations when used to assess the outcomes of angioplasty in autologous arteriovenous fistulas (AVFs). Purpose To investigate a new functional quantifiable index of successful angioplasty for failing AVFs using intraprocedural percutaneous US volume flow (VF) measurements. Materials and Methods This prospective, multicenter, single-arm, cohort clinical trial included consecutive patients with indications for fluoroscopically guided balloon angioplasty due to AVF dysfunction between June 2020 and May 2022. Intraprocedural VF measurements were obtained before the procedure and after balloon dilation using transcutaneous duplex US. The primary end points were the quantification of VF-guided angioplasty outcomes and assessment of the association between postprocedural VF and freedom from target lesion reintervention (TLR) due to recurrence of access failure. Cox multivariate regression analysis was performed to identify predictors of TLR-free survival, which was estimated using Kaplan-Meier methods. Receiver operating characteristic curve analysis was used to determine the optimal cutoff VF value. Results In total, 100 participants (mean age, 67 years ± 12 [SD]; 84 male) were evaluated. The rate of freedom from TLR was 73% at 6 months. The mean pre- and postintervention VF values were 353 mL/min ± 199 and 1045 mL/min ± 413, respectively. Higher VF at completion of angioplasty (hazard ratio, 0.89 per 100 mL/min [95% CI: 0.82, 0.98]; P = .01) and forearm versus upper arm AVF (hazard ratio, 0.51 [95% CI: 0.27, 0.95]; P = .03) were independent predictors of increased freedom from TLR. A postprocedural VF of 720 mL/min (P < .001) was identified as the optimal cutoff point for predicting increased fistula freedom from reintervention and freedom of restenosis for radiocephalic AVFs, compared with an optimal cutoff point of 1120 mL/min (P = .03) for upper arm AVFs. Conclusion Intraprocedural VF measurement is a quantifiable functional index and postprocedural predictor of outcomes following angioplasty for failing dialysis AVFs. ClinicalTrials.gov identifier: NCT04694287 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Prince et al this issue.
Collapse
Affiliation(s)
- Stavros Spiliopoulos
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Panagiotis Filippou
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Ioannis E Giannikouris
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Konstantinos Katsanos
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Konstantinos Palialexis
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Stavros Grigoriadis
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Panagiotis Kitrou
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Elias Brountzos
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| | - Dimitrios Karnabatidis
- From the 2nd Department of Radiology, Interventional Radiology Unit, Attikon University General Hospital, 1st Rimini St, GR 12461 Chaidari, Athens, Greece (S.S., P.F., K.P., S.G., E.B., D.K.); Department of Nephrology and Hemodialysis Unit (I.E.G.) and Department of Interventional Radiology (E.B.), Mediterraneo Hospital, Glyfada, Greece; and Department of Interventional Radiology, School of Medicine, Patras University Hospital, Rion, Greece (K.K., P.K.)
| |
Collapse
|
4
|
Shintaku S, Kawanishi H, Banshodani M, Moriishi M, Takahashi N, Tsuchiya S. Efficacy of drug-coated balloon catheters for patients with short-term recurrent dysfunction of arteriovenous fistula. J Vasc Access 2024:11297298241245853. [PMID: 38641588 DOI: 10.1177/11297298241245853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2024] Open
Abstract
BACKGROUND In this study, we aimed at clarifying the usefulness of drug-coated balloon catheters (DCBs) for arteriovenous fistulas (AVFs) that repeatedly undergo restenosis over a short period and to examine the factors that influence the patency period after DCB use. METHODS This retrospective observational study was conducted using IN.PACT AV in 29 cases of AVFs with repeated restenosis within approximately 3 months, and temporary patency before and after DCB use in the same patients was compared. For target participants, the flow volume, resistive index (RI), and vascular diameter of the brachial artery were measured using an ultrasound diagnostic device. Stenosis diameter, reference vessel diameter, and stenosis length of the lesion were measured before and after DCB dilatation using digital subtraction angiography. RESULTS Before DCB angioplasty, the postintervention primary patency at 3 months was 66%, and the average interval was 92 ± 21 days (mean ± standard deviation). After DCB angioplasty, the postintervention primary patency rates at 3 and 6 months were 92% and 36%, respectively. The postintervention primary patency was significantly higher after than before DCB angioplasty (p < 0.0001). A sub-analysis was performed on 25 patients who were followed up for 4 months or more after DCB. The RI values before and after dilatation with DCB significantly differed between the patency group 4 or more months after DCB and the patency group less than 4 months after DCB. CONCLUSION For AVFs that require frequent PTA over a short period of time, DCB improved the patency rate 3 months after PTA, but the improvement effect at 6 months was limited. The effect of DCB on prolonging the patency rate of AVFs that require frequent PTA over a short period of time may be correlated with the RI value before and after PTA.
Collapse
Affiliation(s)
- Sadanori Shintaku
- Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan
| | - Hideki Kawanishi
- Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan
| | - Masataka Banshodani
- Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan
| | | | | | - Shinichiro Tsuchiya
- Department of Kidney Disease and Blood Purification Therapy, Tsuchiya General Hospital, Hiroshima, Japan
| |
Collapse
|
5
|
Abbadie F, Kosmadakis G, Aguilera D, Piraud A. Duplex ultrasound-guided angioplasty of hemodialysis vascular access. J Vasc Surg 2023; 78:1292-1301.e3. [PMID: 37463647 DOI: 10.1016/j.jvs.2023.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/17/2023] [Accepted: 07/10/2023] [Indexed: 07/20/2023]
Abstract
OBJECTIVE Duplex ultrasound-guided angioplasty (DA) for hemodialysis vascular accesses remains questionable regarding its feasibility and safety. Minor complications (requiring no more treatment than nominal therapy) might be over-reported. Our hypothesis is that this procedure has no significant differences between observed rates and the recommended threshold of main outcomes of the procedure defined by the standards of arteriovenous fistulas (AVF) angioplasty. METHODS In a single-center retrospective study, 298 DA performed on 141 patients from 2015 to 2019 were analyzed. Occluded AVF or concomitant use of radiographic guidance were excluded. Duplex ultrasound parameters were collected up to 1 month before, at the end of angioplasty, and on day 30 after the procedure. Complications were registered, and patency rates were studied at 24 months of follow-up. RESULTS Anatomical success was achieved in 142 procedures (47.7%), clinical success in 284 (95.3%), and hemodynamic success in 283 (95.0%). Major complications-requiring at least a specific therapy-were reported in 8 procedures (2.7%) and minor complications-requiring no adjunctive therapy-in 157 (52.7%). At 24 months, overall postintervention primary patency was 34.0%, primary-assisted patency 87.4%, and secondary patency 92.5%. There were no significant differences of patency rates between groups with or without minor complications (P value for primary patency, 0.08; primary-assisted patency, 0.08; secondary patency, 0.23) or 30% residual stenosis (P value for primary patency, 0.82; primary-assisted patency, 0.46; secondary patency: 0.63). Duplex parameters further improved at postoperative day 30 after angioplasty. CONCLUSIONS DA of AVF is feasible, safe-despite over-reported minor complications having no impact on postintervention patency rates-and efficient. A minor complication can be seen as an event without bad or good consequences. Anatomical definition of success does not fit on DA for hemodialysis vascular access. Further studies are required to define the duplex parameter threshold for efficacy.
Collapse
Affiliation(s)
- Fabrice Abbadie
- Vascular Medicine Unit, Vichy District Hospital, Vichy, France.
| | | | - Didier Aguilera
- Department of Nephrology, Vichy District Hospital, Vichy, France
| | - Aurélien Piraud
- Department of Clinical Research, Vichy District Hospital, Vichy, France
| |
Collapse
|
6
|
Higgins MCSS, Diamond M, Mauro DM, Kapoor BS, Steigner ML, Fidelman N, Aghayev A, Chamarthy MRK, Dedier J, Dillavou ED, Felder M, Lew SQ, Lockhart ME, Siracuse JJ, Dill KE, Hohenwalter EJ. ACR Appropriateness Criteria® Dialysis Fistula Malfunction. J Am Coll Radiol 2023; 20:S382-S412. [PMID: 38040461 DOI: 10.1016/j.jacr.2023.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 12/03/2023]
Abstract
The creation and maintenance of a dialysis access is vital for the reduction of morbidity, mortality, and cost of treatment for end stage renal disease patients. One's longevity on dialysis is directly dependent upon the quality of dialysis. This quality hinges on the integrity and reliability of the access to the patient's vascular system. All methods of dialysis access will eventually result in dialysis dysfunction and failure. Arteriovenous access dysfunction includes 3 distinct classes of events, namely thrombotic flow-related complications or dysfunction, nonthrombotic flow-related complications or dysfunction, and infectious complications. The restoration of any form of arteriovenous access dysfunction may be supported by diagnostic imaging, clinical consultation, percutaneous interventional procedures, surgical management, or a combination of these methods. This document provides a rigorous evaluation of how variants of each form of dysfunction may be appraised and approached systematically. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
| | - Matthew Diamond
- Research Author, Boston Medical Center, Boston, Massachusetts
| | - David M Mauro
- University of North Carolina School of Medicine, Chapel Hill, North Carolina
| | | | | | - Nicholas Fidelman
- Panel Vice-Chair, University of California San Francisco, San Francisco, California
| | - Ayaz Aghayev
- Brigham & Women's Hospital, Boston, Massachusetts
| | - Murthy R K Chamarthy
- Vascular Institute of North Texas, Dallas, Texas; Commission on Nuclear Medicine and Molecular Imaging
| | - Julien Dedier
- Boston Medical Center, Boston, Massachusetts, Primary care physician
| | - Ellen D Dillavou
- WakeMed Hospital System, Raleigh, North Carolina; Society for Vascular Surgery
| | - Mila Felder
- Advocate Christ Medical Center, Oak Lawn, Illinois; American College of Emergency Physicians
| | - Susie Q Lew
- George Washington University, Washington, District of Columbia; American Society of Nephrology
| | | | - Jeffrey J Siracuse
- Boston University School of Medicine, Boston, Massachusetts; Society for Vascular Surgery
| | - Karin E Dill
- Specialty Chair, Emory University Hospital, Atlanta, Georgia
| | - Eric J Hohenwalter
- Specialty Chair, Froedtert & The Medical College of Wisconsin, Milwaukee, Wisconsin
| |
Collapse
|
7
|
Pichot O, Diard A, Bosc JY, Abbadie F, Franco G, Mahé G, Sadaghianloo N. Standardized Methodology for Duplex Ultrasound Examination of Arteriovenous Access for Hemodialysis: A Proposal of the French Society of Vascular Medicine and the French-Speaking Society of Vascular Access. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2213-2220. [PMID: 37544830 DOI: 10.1016/j.ultrasmedbio.2023.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/06/2023] [Accepted: 07/10/2023] [Indexed: 08/08/2023]
Abstract
Duplex ultrasound (DUS) is an essential tool for characterizing and monitoring arteriovenous (AV) access for hemodialysis. The aim of the work described here, requested by the French Society of Vascular Medicine in collaboration with the French-Speaking Vascular Access Society, is to propose a standardized methodology for performing and documenting DUS, taking into account the variety of AV access techniques and the problems routinely encountered. A steering committee reviewed the literature and selected the relevant references. A draft was prepared, and all items with missing or conflicting data were submitted to a Delphi consensus. The final document was discussed and approved by all participants. The principles of DUS evaluation of AV access consist of examination of the afferent artery, the anastomosis and the entire venous drainage system. DUS uses B-mode ultrasound, color flow, pulsed wave and power Doppler analysis. DUS can be used in a variety of clinical situations, which can directly influence the methodology of the examination and the interpretation of the results. Blood flow should be assessed as it correlates with the risk of thrombosis. The measurement should be adapted to the different anatomical and hemodynamic conditions encountered. Characterization of stenosis should take into account the residual diameter of the drainage vein and its hemodynamic consequences. Other complications can be assessed with a standardized DUS examination. When performed according to a rigorous methodology, DUS of the AV access allows a comprehensive assessment of its functionality and eliminates the need for further invasive diagnostic procedures.
Collapse
Affiliation(s)
- Olivier Pichot
- Department of Vascular Medicine, Groupement Hospitalier Mutualiste, Grenoble, France.
| | - Antoine Diard
- Department of Vascular Medicine, Centre Hospitalier Universitaire Bordeaux, France
| | - Jean-Yves Bosc
- Renal Disease Clinics, AIDER Santé, Hôpital Lapeyronie, Montpellier, France
| | - Fabrice Abbadie
- Department of Vascular Medicine, Centre Hospitalier de Vichy, Vichy, France
| | | | - Guillaume Mahé
- Department of Vascular Medicine, Centre Hospitalier Universitaire de Rennes, Rennes, France
| | - Nirvana Sadaghianloo
- Department of Vascular Surgery, Centre Hospitalier Universitaire de Nice, Nice, France
| |
Collapse
|
8
|
Umei K, Toda N, Izumi J, Umeda Y, Iwata M, Nakanishi K, Komiya T. Relationship between resistance index and recirculation rate in vascular access. RENAL REPLACEMENT THERAPY 2022. [DOI: 10.1186/s41100-022-00446-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Abstract
Background
The state of vascular access affects the efficiency of hemodialysis. Poor blood flow of vascular access causes recirculation, which reduces treatment efficiency. In the clinical setting, the resistance index (RI) is a commonly used parameter to evaluate the state of vascular access. However, there are few reports investigating the direct relationship between RI and the recirculation rate. In this study, the relationship between RI and the recirculation rate was investigated using computational fluid dynamics analysis.
Methods
We created a three-dimensional model that mimics vascular access in hemodialysis patients. Next, we input various blood flow waveforms (RI 0.00, 0.50, 0.60, 0.80, and 0.94) into the vascular model. Then, two needles were punctured into the blood vessel model. Blood was removed from the vessel by one needle at a rate of 200 ml/min and returned by the other needle at the same speed. The recirculation rate was calculated using the backflow from the blood return needle.
Results
The recirculation rates for the blood flow waveforms of RI 0.00, 0.50, 0.60, 0.80, and 0.94 were 0.00%, 0.29%, 0.44%, 11.6%, and 28.1%, respectively. The recirculation rate was higher for blood flow with higher RI. In addition, more recirculation occurred during the diastolic phase, when blood flow was slow.
Conclusions
When the minimum blood flow was slower than the hemodialysis blood removal speed, both backflow and the recirculation rate increased. Sufficient diastolic blood flow needs to be maintained to suppress recirculation.
Collapse
|
9
|
Alam F, Al Salmi I, Al Zadjali M, Jha DK, Hannawi S. Demography and Outcomes of Arteriovenous Fistula: Challenges and Future Directions. SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION 2022; 33:627-638. [PMID: 37955455 DOI: 10.4103/1319-2442.389423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2023] Open
Abstract
The incidence and prevalence rates of treated end-stage kidney disease (ESKD) patients are on the rise worldwide. Hemodialysis remains the main modality of providing renal replacement therapy for the ESKD patients, and the preferred vascular access is an arteriovenous fistula (AVF). The objective is to assess the patency rates and primary failures of the AVF. All patients who attended the Royal Hospital in Muscat, Oman, from January 2010 to December 2014 for AVF creation were included in this study. Data were extracted from the hospital's electronic medical record system where data are entered prospectively. During the period of study from 2010 to 2014, 465 primary fistulae were created in 427 patients. The mean age of the patient was 58 years. Only 6% needed general anesthesia, while the rest were done under regional or local anesthesia. Fifty-one percent of the patients were diabetic. Preemptive AVF was constructed in only 12% of patients. Most cases (47%) had left brachiocephalic (BC) fistulae. The left radiocephalic (RC) fistulae constituted 25.7% and the left brachiobasilic fistulae 9.9%. The remaining were constructed in the right upper limb. The total patency was achieved in 80% of fistulae and the failure rate was 20% at 6 months. Whereas, at 12 months, the total patency rate was 71% and the failure rate was 29%. Thus, we can conclude that more than 50% of patients, half of them being females, were diabetics. This resulted in more fistulae being constructed in the arm, namely left BC fistulae and left RC fistulae. Furthermore, it is important to note that only a very small percentage of patients had an established preemptive AVF. These factors may be responsible for a failure rate of 20% and 29% of the AVFs at 6 months and 12 months, respectively.
Collapse
Affiliation(s)
- Faisal Alam
- Department of Surgery, The Royal Hospital, Muscat, Oman
| | - Issa Al Salmi
- Department of Renal Medicine, The Royal Hospital, Muscat, Oman
| | | | | | | |
Collapse
|
10
|
Malik J, de Bont C, Valerianova A, Krupickova Z, Novakova L. Arteriovenous Hemodialysis Access Stenosis Diagnosed by Duplex Doppler Ultrasonography: A Review. Diagnostics (Basel) 2022; 12:diagnostics12081979. [PMID: 36010329 PMCID: PMC9406731 DOI: 10.3390/diagnostics12081979] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 11/16/2022] Open
Abstract
Arteriovenous fistula (AVF) is currently the hemodialysis access with the longest life expectations for the patients. However, even the AVF is at risk for many complications, especially the development of stenosis. The latter can not only lead to inadequate hemodialysis but also lead to AVF thrombosis. Duplex Doppler ultrasonography is a very precise method, in the hands of experienced professionals, for the diagnosis of AVF complications. In this review, we summarize the ultrasound diagnostic criteria of significant stenoses and their indication for procedural therapy.
Collapse
Affiliation(s)
- Jan Malik
- 3rd Department of Internal Medicine, General University Hospital, U Nemocnice 2, 12808 Prague, Czech Republic
- Center for Vascular Access, First Faculty of Medicine of General University Hospital, Charles University, 12108 Prague, Czech Republic
| | - Cora de Bont
- Vascular Laboratory, Bravis Hospital, 4624 VT Bergen op Zoom, The Netherlands
| | - Anna Valerianova
- 3rd Department of Internal Medicine, General University Hospital, U Nemocnice 2, 12808 Prague, Czech Republic
- Center for Vascular Access, First Faculty of Medicine of General University Hospital, Charles University, 12108 Prague, Czech Republic
| | - Zdislava Krupickova
- 3rd Department of Internal Medicine, General University Hospital, U Nemocnice 2, 12808 Prague, Czech Republic
- Center for Vascular Access, First Faculty of Medicine of General University Hospital, Charles University, 12108 Prague, Czech Republic
| | - Ludmila Novakova
- Faculty of Mechanical Engineering, Jan Evangelista Purkyne University, 40096 Usti nad Labem, Czech Republic
| |
Collapse
|
11
|
Wu CK, Tarng DC, Yang CY, Leu JG, Lin CH. Factors affecting arteriovenous access patency after percutaneous transluminal angioplasty in chronic haemodialysis patients under vascular access monitoring and surveillance: a single-centre observational study. BMJ Open 2022; 12:e055763. [PMID: 35074822 PMCID: PMC8788314 DOI: 10.1136/bmjopen-2021-055763] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES Maintenance of vascular access (VA) patency after percutaneous transluminal angioplasty (PTA) is important and remains a challenge despite VA monitoring and surveillance. The aim of this study was to examine factors affecting the post-PTA arteriovenous access (AVA) patency in patients who have been on close VA monitoring and surveillance for access flow. DESIGN Retrospective cohort study. SETTING A single medical centre in Taiwan. PARTICIPANTS Records of patients who received chronic haemodialysis between 1 January 2017 and 31 December 2018 were retrospectively reviewed. Patients were divided into two groups (without or with PTA intervention on AVA). PRIMARY AND SECONDARY OUTCOME Patients were followed until reintervention PTA, termination or abandoned VA or end of study. In addition to routine monitoring, VA flow surveillance was performed every 3 months for detection of VA dysfunction adhering to Kidney Disease Outcomes Quality Initiative guidelines. RESULTS A total of 508 patients were selected for study inclusion (with PTA, n=231; without PTA, n=277). At baseline, variables that differed between groups included malignancy and levels of albumin, uric acid, potassium, phosphorous, high-density lipoprotein, total bilirubin and ferritin (all p<0.05). Significant between-group differences were observed for β-adrenergic blocking agents (with PTA, 49.8%; without PTA, 37.5%; p, 0.007) and ADP inhibitors (with PTA, 23.8%; without PTA, 11.2%; p<0.001). Among patients with PTA, those with acute myocardial infarction, high ferritin level or arteriovenous graft (AVG) had a significantly higher risk of reintervention post-PTA (p<0.05). Dipeptidyl peptidase-4 inhibitors, thiazolidinediones, ADP inhibitors, and warfarin use were predictors of post-PTA patency (p<0.05). CONCLUSIONS AVG access type, acute myocardial infarction, and high ferritin levels are risk factors for re-intervention post-PTA. These findings may be useful in the development of prophylactic strategies for monitoring VA function and tailoring surveillance programs for these dialysis patients.
Collapse
Affiliation(s)
- Chung-Kuan Wu
- Division of Nephrology, Department of Internal Medicine, Shin Kong Wu Ho Su Memorial Hospital, Taipei, Taiwan
- Dialysis Access Management Center, Department of Internal Medicine, Shin Kong Wu Ho Su Memorial Hospital, Taipei, Taiwan
- School of Medicine, Fu Jen Catholic University, New Taipei, Taiwan
| | - Der-Cherng Tarng
- Department of Institute of Physiology, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chih-Yu Yang
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
- Division of Clinical Toxicology and Occupational Medicine, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Jyh-Gang Leu
- Division of Nephrology, Department of Internal Medicine, Shin Kong Wu Ho Su Memorial Hospital, Taipei, Taiwan
- School of Medicine, Fu Jen Catholic University, New Taipei, Taiwan
| | - Chia-Hsun Lin
- School of Medicine, Fu Jen Catholic University, New Taipei, Taiwan
- Division of Cardiovascular Surgery, Department of Surgery, Shin Kong Wu Ho Su Memorial Hospital, Taipei, Taiwan
| |
Collapse
|
12
|
Yii E, Yii MK, Thwaites S, Zhu J, Chong T, Tong L, Nair S. Receiver operating characteristic curve analysis of arteriovenous dialysis access flow using ultrasound. ANZ J Surg 2021; 92:461-465. [PMID: 34806268 DOI: 10.1111/ans.17378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/26/2021] [Accepted: 10/26/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUNDS Despite numerous studies investigating the use of ultrasound (US) in assessing arteriovenous fistulas (AVF), there are no universally agreed threshold flow velocities in diagnosing significantly abnormal flow that are useful in predicting thrombotic flow-related dysfunction. This study evaluates a predictive model using receiver operating characteristic curve (ROC) analyses to establish threshold velocities. METHODS Five hundred and eleven US scans were analysed. ROC curves were used to determine the optimal threshold time average mean velocity (TAMV), peak systolic velocity (PSV) and end diastolic velocity (EDV) of the brachial artery supplying the AVF in determining the need for intervention or thrombosis within 3 months of the scans. Estimated flow volume (FV) ROC was used as an evaluative comparison. RESULTS There were 356 negative and 155 positive scan results in relation to the need for intervention or thrombosis. Empirical flow velocity parameters of TAMV, EDV and PSV were analysed using ROC curves, yielding an area under the curve (AUC) of 0.95, 0.92 and 0.86, respectively. FV ROC analysis yields a comparative AUC of 0.90. A TAMV cut-off at 48.6 cm/s yielded the highest AUC. Subgroup analysis yielded an optimal TAMV cut-off of 45 cm/s for forearm and 49 cm/s for arm AVF. The EDV was also highly predictive of outcomes. PSV has the lowest accuracy. CONCLUSION The TAMV of inflow brachial artery to AVF is highly predictive of outcomes of thrombotic flow-related dysfunction. Our study confirms TAMV cut-offs of 45 cm/s for forearm and 49 cm/s for arm AVF. These results require prospective validation.
Collapse
Affiliation(s)
- Erwin Yii
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia
| | - Ming Kon Yii
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia.,Vascular and Transplant Surgery Unit at Monash Health, Monash Medical Centre Clayton, Clayton, Victoria, Australia
| | - Stephen Thwaites
- Vascular and Transplant Surgery Unit at Monash Health, Monash Medical Centre Clayton, Clayton, Victoria, Australia
| | - John Zhu
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia
| | - Timothy Chong
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia
| | - Lauren Tong
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia
| | - Sachin Nair
- Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia
| |
Collapse
|
13
|
Expert consensus on the establishment and maintenance of native arteriovenous fistula. Chronic Dis Transl Med 2021; 7:235-253. [PMID: 34786543 PMCID: PMC8579016 DOI: 10.1016/j.cdtm.2021.05.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Indexed: 11/28/2022] Open
Abstract
Vascular access is the lifeline of hemodialysis patients. There are great differences in the establishment and use of vascular access in different countries and regions around the world. We believe that on the basis of good evaluation and planning, it is recommended that hemodialysis patients choose native arteriovenous fistula first. In view of the new progress of vascular access views domestic and international at home and abroad in recent years, we organized experts to recommend the establishment and maintenance of arteriovenous fistula (AVF) for the Chinese population, including preoperative evaluation and planning of the establishment of AVF, AVF surgery, perioperative drug intervention measures and postoperative maintenance, and put forward suggestions for future research directions. The recommendations in this consensus are general and clinicians need to make treatment decisions based on the actual situation.
Collapse
|
14
|
An Investigation on the One-year Rate of Arteriovenous Fistula Failure and Its Related Factors in Patients with End-stage Renal Disease; an Experience in Golestan Province of Iran. Nephrourol Mon 2021. [DOI: 10.5812/numonthly.117420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background: Aortic arch calcification (AAC) is very common in hemodialysis patients and is associated with cardiovascular events and the incidence of arteriovenous fistula (AVF) failure. In order to predict the prognosis of patients, a study was conducted to determine the annual failure rate of AVF and its related factors. Methods: This cross-sectional study was performed on 145 patients with end-stage renal disease (ESRD) who were AVF candidates, visiting a referral center in Golestan province of Iran. After the insertion of intravenous arterial fistulas, posterior-anterior chest x-rays were captured, and the grafts were classified by a radiologist. Patients were followed for one year, and the rates of fistula failure (FF) and cardiovascular mortality were recorded. Finally, the data were entered into SPSS 19 software and analyzed by the Chi-square test. Results: Of 112 patients followed up for one year, 56.2% were men. During the one-year follow-up period, 5.3% of the patients developed arteriovenous FF, and this event was more common in men, but the difference was not statistically significant. The majority of the AVF candidates had a history of diabetes and hypertension, but no association was found between the one-year FF rate and these two diseases. Nearly 7.7% of the patients had grade III calcification, but no significant relationship was observed between the AAC grade and AVF failure rate. Conclusions: The rate of one-year FF was higher among ESRD patients with a history of chronic kidney diseases. Our results also demonstrated that the mortality rate is higher in patients with a high degree of AAC and patients with medical history (cardiovascular disease and diabetes).
Collapse
|
15
|
Malik J, Lomonte C, Meola M, de Bont C, Shahverdyan R, Rotmans JI, Saucy F, Jemcov T, Ibeas J. The role of Doppler ultrasonography in vascular access surveillance-controversies continue. J Vasc Access 2021; 22:63-70. [PMID: 34281410 PMCID: PMC8619723 DOI: 10.1177/1129729820928174] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Chronic hemodialysis therapy required regular entry into the patient’s blood stream with adequate flow. The use of arteriovenous fistulas and grafts is linked with lower morbidity and mortality than the use of catheters. However, these types of accesses are frequently affected by stenoses, which decrease the flow and lead to both inadequate dialysis and access thrombosis. The idea of duplex Doppler ultrasound surveillance is based on the presumption that in-time diagnosis of an asymptomatic significant stenosis and its treatment prolongs access patency. Details of performed trials are conflicting, and current guidelines do not support ultrasound surveillance. This review article summarizes the trials performed and focuses on the reasons of conflicting results. We stress the need of precise standardized criteria of significant access stenosis and the weakness of the metaanalyses performed.
Collapse
Affiliation(s)
- Jan Malik
- Center for Vascular Access, General University Hospital and First Faculty of Medicine, Charles University, Prague, Czech Republic.,3rd Department of Internal Medicine, General University Hospital and First Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Carlo Lomonte
- Division of Nephrology, Miulli General Hospital, Acquaviva delle Fonti, Italy
| | - Mario Meola
- Institute of Life Sciences, Sant'Anna of Advanced Studies and Department of Internal Medicine, Pisa University, Pisa, Italy
| | - Cora de Bont
- Vascular Laboratory, Bravis Hospital, Bergen op Zoom, The Netherlands
| | | | - Joris I Rotmans
- Department of Internal Medicine, Leiden University Medical Center, The Netherlands
| | - Francois Saucy
- Service of Vascular Surgery, Department of Heart and Vessels, University Hospital, Lausanne, Switzerland
| | - Tamara Jemcov
- Department of Nephrology, Clinical Hospital Centre Zemun, Belgrade, Serbia.,School of Medicine, University of Belgrade, Belgrade, Serbia
| | - Jose Ibeas
- Nephrology Department, Parc Taulí University Hospital, Parc Taulí Research and Innovation Institute (I3PT), Autonomous University of Barcelona, Barcelona, Spain
| |
Collapse
|
16
|
Tsuboi M, Suzuki H, Kawai H, Ejima T, Mitsuishi F. Vascular sound visualization system is useful for monitoring and surveillance of vascular access. J Vasc Access 2021; 23:390-397. [PMID: 33586508 DOI: 10.1177/1129729821993984] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUNDS Vascular access (VA) is a lifeline for maintenance hemodialysis patients. Monitoring and surveillance of VA, therefore, play an important role for maintaining VA patency. Surveillance needs special apparatus to estimate the VA function, while, monitoring including physical examination does not usually need such devices but highly skill-dependent and qualitative. PURPOSE We report the clinical utility in monitoring and surveillance of VA using a newly developed electronic stethoscope and vascular sound visualization application. METHODS One hundred eight patients participated in the study. The vascular sounds were collected using the electronic stethoscope, converted into digital data, sent wirelessly to a personal computer, and then calculated. The units for the calculated intensity of the vascular sound were decibel [dB]. The intensity, however, was normalized as INDEX values ranging from 0 to 99 for practical use. Correlation between INDEX and the mean flow volume (mFV) and resistance index (RI) of brachial artery measured by Doppler ultrasound sonography were examined for VA surveillance. INDEX was continually measured at each dialysis session in ten patients who underwent the angioplasty for VA monitoring. RESULTS INDEX significantly correlated with the mFV (coefficient of correlation value = 0.68, p < 0.001) and RI (coefficient of correlation value = -0.51, p < 0.001) of brachial artery. Using the calculated cut-off values, the accuracy of INDEX for the diagnosis of AVF dysfunction ranged from 66% to 82%. INDEX attained the peak just after the angioplasty of culprit lesions and gradually decreased from one patient to another. CONCLUSION These results suggest that vascular sound visualization system can be useful in VA monitoring and surveillance for detecting and predicting the access stenosis.
Collapse
Affiliation(s)
| | | | | | - Toru Ejima
- Kaikoukai Anjo Kyoritsu Clinic, Aichi, Japan
| | | |
Collapse
|
17
|
Miyamoto K, Sato T, Momohara K, Ono S, Yamaguchi M, Katsuno T, Sakurai H, Imai H, Ito Y. Analysis of factors for post–percutaneous transluminal angioplasty primary patency rate in hemodialysis vascular access. J Vasc Access 2020; 21:892-899. [DOI: 10.1177/1129729820910555] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Background: Although percutaneous transluminal angioplasty has been established as a first-line therapy for access failure in dialysis, there are few reports on primary patency after percutaneous transluminal angioplasty. We investigated factors associated with primary patency following the first percutaneous transluminal angioplasty performed after vascular access construction in patients with arteriovenous fistula, including blood flow volume before and after percutaneous transluminal angioplasty and previously reported factors. Methods: We used medical records at six dialysis centers to retrospectively identify and analyze prognostic factors for primary patency after percutaneous transluminal angioplasty in 159 patients with arteriovenous fistula who underwent initial percutaneous transluminal angioplasty after vascular access construction. Results: Multivariate analysis with the Cox proportional hazard model showed that primary patency after percutaneous transluminal angioplasty in patients with arteriovenous fistula was significantly associated with lesion length (hazard ratio, 1.76; 95% confidence interval, 1.01–3.07; P = 0.045), and blood flow volume after percutaneous transluminal angioplasty (hazard ratio, 0.71; 95% confidence interval, 0.60–0.84; P < 0.001). When blood flow volume after percutaneous transluminal angioplasty was classified into three categories, risks of outcome events defining the end of primary patency after percutaneous transluminal angioplasty were significantly lower for 400–630 mL/min (hazard ratio, 0.38; 95% confidence interval, 0.21–0.68; P = 0.001) and >630 mL/min (hazard ratio, 0.16; 95% confidence interval, 0.06–0.40; P < 0.001) compared with <400 mL/min. Conclusion: Our study showed that blood flow volume after percutaneous transluminal angioplasty is an important prognostic factor for primary patency after percutaneous transluminal angioplasty in patients with arteriovenous fistula.
Collapse
Affiliation(s)
- Kanyu Miyamoto
- Department of Nephrology, Kizawa Memorial Hospital, Minokamo, Japan
| | - Takashi Sato
- Vascular Access Treatment Center, Kaikoukai Central Clinic, Nagoya, Japan
| | - Keisuke Momohara
- Vascular Access Treatment Center, Kaikoukai Central Clinic, Nagoya, Japan
| | - Sumihisa Ono
- Department of Nephrology, Kizawa Memorial Hospital, Minokamo, Japan
| | - Makoto Yamaguchi
- Department of Nephrology and Rheumatology, Aichi Medical University, Nagakute, Japan
| | - Takayuki Katsuno
- Department of Nephrology and Rheumatology, Aichi Medical University, Nagakute, Japan
| | - Hiroshi Sakurai
- Vascular Access Treatment Center, Kaikoukai Central Clinic, Nagoya, Japan
| | - Hirokazu Imai
- Department of Nephrology and Rheumatology, Tajimi City Hospital, Tajimi, Japan
| | - Yasuhiko Ito
- Department of Nephrology and Rheumatology, Aichi Medical University, Nagakute, Japan
| |
Collapse
|
18
|
Zhang D, Zhang Z, Wan L, Chang J, Zhao R. Characteristics of non-mature but functional autogenous radiocephalic fistulas in hemodialysis patients: A prospective cohort study. J Vasc Access 2019; 21:636-645. [PMID: 31884877 DOI: 10.1177/1129729819897158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
TARGET To compare the ultrasound characteristics between functional, mature arteriovenous fistulas and functional, non-mature arteriovenous fistulas and to identify the predictors of arteriovenous fistula maturation in the forearm. METHODS Patients with newly set-up functional arteriovenous fistulas were enrolled in this prospective cohort study. Ultrasound examinations were conducted pre-operatively and post-operatively. The inner vessel diameter, blood flow volume, and resistance index were measured and compared between the maturation group (Group M) and non-maturation group (Group N). Baseline parameters were calculated to determine the predictors of non-maturation of arteriovenous fistulas. RESULTS All 52 patients with functional arteriovenous fistulas, who were categorized into Group M (25 patients, 48.08%) and Group N (27 patients, 51.92%), finished 24 weeks of follow-up after arteriovenous fistula surgery. The arteriovenous fistulas displayed a significant and rapid increase in the vessel diameter (mean increase of 1.34 times in the arteries and 1.92 times in the veins) and blood flow volume (mean increase of 9.29 times of the arteries and 43.66 times of the veins) and a decrease in the resistance index (mean decrease in 48.00% in the arteries) 8 weeks after surgery. Group N had a lesser increase in the vessel diameters (1.78 times vs 2.06 times, t = -3.136, p = 0.003) and blood flow volume (33.98 times vs 54.11 times, t = -2.383, p = 0.021) of the cephalic vein draining segments (a6) than Group M. The baseline diameter of a6 was the only independent predictor (regression coefficient = 26.229, p = 0.008) of maturation of the functional arteriovenous fistulas after correcting for sex, age, diabetes kidney disease, weight, and height. CONCLUSION The baseline diameter of the cephalic vein was the only predictor of arteriovenous fistula maturation based on the pre-operative ultrasound measurements in Chinese hemodialysis patients.
Collapse
Affiliation(s)
- Dongliang Zhang
- Blood Purification Center of Nephrology Department, Peking University International Hospital, Beijing, China
| | - Zhoucang Zhang
- Blood Purification Center of Nephrology Department, Peking University International Hospital, Beijing, China
| | - Li Wan
- Blood Purification Center of Nephrology Department, Peking University International Hospital, Beijing, China
| | - Jingjing Chang
- Blood Purification Center of Nephrology Department, Peking University International Hospital, Beijing, China
| | - Rui Zhao
- Ultrasound Department, Peking University International Hospital, Beijing, China
| |
Collapse
|
19
|
Hadimeri U, Wärme A, Nasic S, Fransson SG, Wigelius A, Stegmayr B. Angiography and phlebography in a hemodialysis population: A retrospective analysis of interventional results. Int J Artif Organs 2019; 42:675-683. [PMID: 31303134 PMCID: PMC6826886 DOI: 10.1177/0391398819863429] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE To clarify the reasons and beneficial effects and duration of arteriovenous fistula patency after radiological interventions in arteriovenous fistula. The patients investigated were referred due to arteriovenous fistula access flow problems. MATERIAL AND METHODS In 174 patients, 522 radiological investigations and endovascular treatments such as percutaneous transluminal angioplasty were analyzed, retrospectively. All investigations were performed due to clinical suspicion of impaired arteriovenous fistula function. RESULTS Arterial stenosis was significantly more frequent among patients with diabetic nephropathy (p < 0.001) and interstitial nephritis (p < 0.001). According to the venous stenosis, the diagnosis did not affect the frequency (p = 0.22) or the degree (p = 0.39) of stenosis. The degree of stenosis prior to percutaneous transluminal angioplasty correlated significantly with the degree of remaining stenosis after intervention (p < 0.001). Of the 174 patients, 123 (71%) performed a total of 318 investigations including percutaneous transluminal angioplasty. Repeated percutaneous transluminal angioplasty was performed significantly more often in patients with diabetic nephropathy. The median times to the first percutaneous transluminal angioplasty and to the subsequent percutaneous transluminal angioplasties were 9.5 and 5 months, respectively. Arteriovenous fistula in patients with diabetic nephropathy performed similar to most other diagnoses, although performing more percutaneous transluminal angioplasty/patient than most other diagnoses. CONCLUSION Many patients could maintain long-term patency of arteriovenous fistula, including those with diabetic nephropathy, with repeated interventions; this motivates a closer follow-up for these patients. Clinically significant stenosis should be dilated as meticulously and as soon as possible. Occlusions of the arteriovenous fistula in most instances can be successfully thrombolyzed or dilated upon early diagnosis.
Collapse
Affiliation(s)
- Ursula Hadimeri
- Department of Medical and Health Sciences, Linkoping University, Linkoping, Sweden.,Department of Radiology, Skaraborg Hospital, Skövde, Sweden
| | - Anna Wärme
- Department of Internal Medicine and Clinical Nutrition, Institution of Medicine, University of Gothenburg, Gothenburg, Sweden.,Department of Nephrology, Skaraborg Hospital, Skövde, Sweden
| | - Salmir Nasic
- Department of Research and Development, Skaraborg Hospital, Skövde, Sweden
| | - Sven-Göran Fransson
- Department of Medical and Health Sciences, Linkoping University, Linkoping, Sweden.,Department of Radiology, Linkoping University, Linkoping, Sweden
| | - Ann Wigelius
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Bernd Stegmayr
- Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden
| |
Collapse
|
20
|
Mean Platelet Volume Predicts Vascular Access Events in Hemodialysis Patients. J Clin Med 2019; 8:jcm8050608. [PMID: 31060235 PMCID: PMC6571831 DOI: 10.3390/jcm8050608] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 04/25/2019] [Accepted: 05/02/2019] [Indexed: 12/21/2022] Open
Abstract
Arteriovenous fistula (AVF) and arteriovenous graft (AVG) is the vascular access (VA) of 78% of hemodialysis patients (HD) in France. VA dysfunction corresponding to either stenosis requiring angioplasty or acute thrombosis is responsible for 30% of hospitalizations. Mean platelet volume (MPV) is a biological marker of cardiovascular events. We studied MPV in a cohort of HD patients as a predictive marker of VA dysfunction. We conducted a prospective monocentric cohort study that included patients with AVF or AVG on chronic HD (n = 153). The primary outcome was the incidence of VA dysfunction regarding MPV value. The median MPV was 10.8 fL (7.8-13.5), and four groups were designed according to MPV quartiles. Fifty-four patients experienced the first event of VA dysfunction. The incidence of VA dysfunction was higher in patients with the highest MPV: 59% (23 events), 34% (14 events), 27% (11 events), and 18% (6 events), respectively, for the fourth, third, second, and first quartiles (p = 0.001). Multivariate analysis confirmed an independent association between MPV and VA dysfunction-OR 1.52 (1.13-2.07), p < 0.001. VA dysfunction is predicted by MPV level. Patients with the highest MPV have the highest risk of VA events.
Collapse
|
21
|
Ren W, Du Y, Jiang H, Xu D. Effect of Hydraulic Expansion on Arteriovenous Fistula of Hemodialysis Patients. Thorac Cardiovasc Surg 2019; 69:63-69. [PMID: 30738417 DOI: 10.1055/s-0039-1678543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Chronic kidney disease has become a serious public health problem in China. Our study is to explore effect of hydraulic expansion on arteriovenous fistula (AVF) of hemodialysis patients. METHODS A total of 190 patients with end-stage renal disease (ESRD) were randomly divided into hydraulic expansion group (n = 117) and conventional surgery group (n = 73). Age, sex, the cause of ESRD, height, weight, body mass index (BMI), blood pressure, and diameter of artery and vein from ultrasonography before surgery from patients were recorded. Doppler ultrasonography of vessel was performed with a 12-MHz scanning probe for vascular measurements. The time of first cannulation was recorded. Primary and secondary patency rates were compared between the two groups. RESULTS The mean arterial pressure for this cohort of patients was around 98.12 mm Hg. The mean diameters of artery and vein ready for anastomoses measured by ultrasonography before surgery were 1.96 and 2.04 mm, respectively. Age, weight, BMI, sex ratio, the cause of renal failure, history of catheter insertion, mean arterial pressure, frequency of hemodialysis, blood flow of hemodialysis, and the mode of anastomoses of AVF in conventional surgery group were similar to hydraulic expansion group. There were no differences in stroke volume of radius arterial and venous pressure before dilation between the two groups. The stroke volume of radius artery increased significantly after hydraulic expansion than before dilation and control group. The primary patency rates of AVF in patients with hydraulic expansion were higher significantly than conventional surgery group. The secondary patency rates in conventional surgery group were not different from hydraulic expansion group. CONCLUSION Hydraulic expansion showed no difference from conventional surgery in complication after operation, and could decrease the time reliance on catheters and the risk of catheter-related infection, thrombosis, and decrease the related medical care costs.
Collapse
Affiliation(s)
- Wanjun Ren
- Department of Nephrology, Blood Purification Center, Jinan Central Hospital, Shandong University, Jinan, Shandong, People's Republic of China
| | - Yuejuan Du
- Department of Nephrology, Blood Purification Center, Jinan Central Hospital, Shandong University, Jinan, Shandong, People's Republic of China
| | - Huili Jiang
- Department of Nephrology, Blood Purification Center, Jinan Central Hospital, Shandong University, Jinan, Shandong, People's Republic of China
| | - Dongmei Xu
- Department of Nephrology, Qianfoshan Hospital, Shandong University, Jinan, Shandong, People's Republic of China
| |
Collapse
|
22
|
Hasuike Y, Kakita N, Aichi M, Masachika S, Kantou M, Ikeda Takahashi S, Nanami M, Nagasawa Y, Kuragano T, Nakanishi T. Imbalance of coagulation and fibrinolysis can predict vascular access failure in patients on hemodialysis after vascular access intervention. J Vasc Surg 2019; 69:174-180.e2. [DOI: 10.1016/j.jvs.2018.04.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Accepted: 04/07/2018] [Indexed: 01/15/2023]
|
23
|
Kairaitis LK, Collett JP, Swinnen J. Diameter of inflow as a predictor of radiocephalic fistula flow. J Vasc Access 2018; 19:548-554. [DOI: 10.1177/1129729818761306] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Introduction: The optimal method for vascular access surveillance is largely unknown. A previous case–control study suggested a simplified anatomical measure obtained by Doppler ultrasound—the narrowest segment of the circuit or “minimal luminal diameter” may identify patients with a dysfunctional radiocephalic arteriovenous fistula. The relationship between minimal luminal diameter and access flow (Qa) in the radiocephalic arteriovenous fistula has not previously been studied. Methods: Patients undergoing Doppler ultrasound of a radiocephalic arteriovenous fistula over an 8-month period were identified retrospectively. Minimal luminal diameter was identified and demographic and clinical data were collected. Qa was estimated by Doppler estimation of brachial artery flow. The relationship between minimal luminal diameter and Qa was examined by correlation and using different levels of minimal luminal diameter as a simplified measure to detect or exclude low Qa (<600 mL/min). Results: A total of 81 Doppler ultrasound scans were performed. In all, 26 scans demonstrated brachial artery flow <600 mL/min. Simple logistic regression indicated a weak statistical relationship between the minimal luminal diameter and Qa (R2 = 0.27, p < 0.01). Minimal luminal diameter performed poorly as a marker of low Qa with low specificity, however, showed high negative predictive value for ruling out low Qa at a minimal luminal diameter of 3.2 mm or higher (94%). Qa estimated by brachial artery flow correlated well with Qa estimated by indicator dilution (R2 = 0.83, p < 0.01) without significant mean difference or proportional bias. Conclusion: Minimal luminal diameter correlates weakly with Qa. Low minimal luminal diameter values should not be used in isolation to determine low Qa for a radiocephalic arteriovenous fistula. Conversely, minimal luminal diameter >3.2 mm largely excludes a low-flow radiocephalic arteriovenous fistula in this cohort. Brachial artery flow is a reasonable measure of Qa in comparison with indicator dilution.
Collapse
Affiliation(s)
- Lukas K Kairaitis
- Western Renal Services, Westmead Hospital, Westmead, NSW, Australia
- School of Medicine, Western Sydney University, Campbelltown, NSW, Australia
| | - James P Collett
- Western Renal Services, Westmead Hospital, Westmead, NSW, Australia
| | - Jan Swinnen
- Western Renal Services, Westmead Hospital, Westmead, NSW, Australia
- Department of Surgery, Westmead Hospital, Westmead, NSW, Australia
- The University of Sydney at Western Clinical School, Westmead Hospital, NSW, Australia
| |
Collapse
|
24
|
Caro Monroig A, Reddy SN, Chick JFB, Sammarco TE, Chittams JL, Trerotola SO. Fistulography of a Patent Hemodialysis Access: When Not to Treat and Implications for Establishing a Nontreatment Rate. J Vasc Interv Radiol 2018; 29:376-382. [PMID: 29395899 DOI: 10.1016/j.jvir.2017.11.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 10/23/2017] [Accepted: 11/13/2017] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To establish a rate of nonintervention in patients referred for hemodialysis access fistulography and to report clinical and fistulographic variables associated with nonintervention. MATERIALS AND METHODS Encounters for fistulography were reviewed from 2001 to 2016 to determine annual rates of nontreatment over 15 years. Next, an access database was used to retrospectively identify patients undergoing fistulography from 2010 to 2016. Patients who underwent fistulography without intervention (angioplasty or stent placement) served as the nontreatment group (NTG; n = 76). Patients who underwent fistulography with intervention served as the control group (CG; n = 77). Patients with thrombosed accesses were excluded. Clinical indications for intervention and physical examination findings were correlated with fistulography. Need for subsequent percutaneous intervention was recorded. RESULTS Annual nontreatment rates ranged from 3% to 14% (median, 10%). Preprocedure thrill was encountered in 45 patients in the NTG (59%) vs 6 in the CG (7.8%; P < .01). Aneurysm as indication for fistulography was more common in the NTG than the CG (19 [25%] vs 4 [5%]; P < .01). The NTG had a higher proportion of aneurysms noted on fistulography as well (38 [50%] vs 19 [25%]; P < .01). The CG had a higher proportion of patients needing subsequent percutaneous intervention vs the NTG (73 [96%] vs 38 [50%]; P < .001). CONCLUSIONS A suggested nonintervention rate for hemodialysis access fistulography is 10%. Patients in the NTG were more likely to have a thrill on physical examination or to present with aneurysms as the clinical indicator. NTG patients were less likely to require subsequent percutaneous intervention.
Collapse
Affiliation(s)
- Angeliz Caro Monroig
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, Perelman School of Medicine, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104
| | - Shilpa N Reddy
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, Perelman School of Medicine, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104
| | - Jeffrey Forris Beecham Chick
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, Perelman School of Medicine, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104; Department of Radiology, Division of Vascular and Interventional Radiology, University of Michigan Medical Center, Ann Arbor, Michigan
| | - Therese E Sammarco
- Biostatistics Consulting Unit, Office of Nursing Research, School of Nursing, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Jesse L Chittams
- Biostatistics Consulting Unit, Office of Nursing Research, School of Nursing, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Scott O Trerotola
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, Perelman School of Medicine, 1 Silverstein, 3400 Spruce St., Philadelphia, PA 19104.
| |
Collapse
|