1
|
Is the efficacy of cone beam computed tomography in the diagnosis of tooth ankylosis influenced by dose reduction protocols? Oral Surg Oral Med Oral Pathol Oral Radiol 2023; 135:129-135. [PMID: 36241601 DOI: 10.1016/j.oooo.2022.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 07/09/2022] [Accepted: 08/17/2022] [Indexed: 12/25/2022]
Abstract
OBJECTIVE To evaluate the diagnostic efficacy of cone beam computed tomography (CBCT) examinations acquired with varying dose protocols in the diagnosis of simulated tooth ankylosis (TA). STUDY DESIGN Tooth ankylosis was simulated in 15 of 30 teeth, and CBCT examinations were acquired at 3 mA levels (8, 6.3, and 5) and 3 voxel sizes (0.08, 0.125, and 0.2 mm). Four radiologists independently assessed the presence of TA using a 5-point scale. Sensitivity, specificity, and area under the curve (AUC) obtained through receiver operating characteristic analysis were compared among mA levels and voxel sizes using two-way analysis of variance (α = 0.05). Intra- and interexaminer reliability levels were assessed with the weighted kappa examination. RESULTS Sensitivity was low (0.32-0.49), and specificity was reasonably high (0.71-0.83). Mean values of AUC were low, ranging between 0.54 and 0.67, which reveals poor overall discrimination between health and disease. The detection of TA was not significantly influenced by mA level or voxel size (P > .05). Intra- and interexaminer agreements ranged from slight to moderate (0.160-0.535) and from fair to substantial (0.236-0.697), respectively. CONCLUSIONS Despite the limited efficacy of CBCT for TA detection, when indicated as a complementary examination, mA reduction should be considered for dose optimization purposes.
Collapse
|
2
|
Martins LAC, Brasil DM, Freitas DQ, Oliveira ML. A novel method of objectively detecting tooth ankylosis using cone-beam computed tomography: A laboratory study. Imaging Sci Dent 2023; 53:61-67. [PMID: 37006786 PMCID: PMC10060758 DOI: 10.5624/isd.20220186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/12/2022] [Accepted: 12/14/2022] [Indexed: 01/12/2023] Open
Abstract
Purpose The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test (α=0.05). Results The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions (P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non-ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas (P>0.05). Conclusion The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.
Collapse
Affiliation(s)
- Luciano Augusto Cano Martins
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Danieli Moura Brasil
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Deborah Queiroz Freitas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Matheus L Oliveira
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
3
|
Anbiaee N, Shafieian R, Shiezadeh F, Shakeri M, Naqipour F. Correlation between gray values in cone-beam computed tomography and histomorphometric analysis. Imaging Sci Dent 2022; 52:375-382. [PMID: 36605865 PMCID: PMC9807799 DOI: 10.5624/isd.20220051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 07/12/2022] [Accepted: 07/25/2022] [Indexed: 12/28/2022] Open
Abstract
Purpose The aim of this study was to analyze the relationships between bone density measurements obtained using cone-beam computed tomography (CBCT) and morphometric parameters of bone determined by histomorphometric analysis. Materials and Methods In this in vivo study, 30 samples from the maxillary bones of 7 sheep were acquired using a trephine. The bone samples were returned to their original sites, and the sheep heads were imaged using CBCT. On the CBCT images, gray values were calculated. In the histomorphometric analysis, the total bone volume, the trabecular bone volume (referred to simply as bone volume), and the trabecular thickness were assessed. Results Statistical testing showed significant correlations between CBCT gray values and total bone volume (r=0.537, P=0.002), bone volume (r=0.672, P<0.001), and trabecular thickness (r=0.692, P<0.001), as determined via the histomorphometric analysis. Conclusion The results indicate a significant and acceptable association between CBCT gray values and bone volume, suggesting that CBCT may be used in bone densitometry.
Collapse
Affiliation(s)
- Najmeh Anbiaee
- Department of Oral and Maxillofacial Radiology, Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Reihaneh Shafieian
- Department of Anatomy and Cell Biology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Farid Shiezadeh
- Department of Periodontology, Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammadtaghi Shakeri
- Department of Community Medicine and Public Health, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fatemeh Naqipour
- Department of Oral and Maxillofacial Radiology, Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
4
|
Deng F, Touska P, Reinshagen KL, Curtin HD, Juliano AF. Diagnostic Performance of Conebeam CT Pixel Values in Active Fenestral Otosclerosis. AJNR Am J Neuroradiol 2021; 42:1667-1670. [PMID: 34140277 DOI: 10.3174/ajnr.a7192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 04/16/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Quantitative bone densitometry on multidetector CT of the temporal bone is a diagnostic adjunct for otosclerosis in its active (spongiotic) phase, but translating this technique to conebeam CT is limited by the technical variability of conebeam CT pixel values. The purpose of this study was to evaluate the performance of internally calibrated conebeam CT pixel value measurements that can enable the determination of active fenestral otosclerosis (otospongiosis). MATERIALS AND METHODS This study included 37 ears in 22 patients with a clinical diagnosis of otospongiosis in those ears and 35 ears in 22 control patients without the diagnosis. Temporal bone conebeam CT was performed. ROIs were set anterior to the oval window, in the lateral semicircular canal bone island, and in a nearby aerated space. Mean conebeam CT pixel values in these regions determined the relative attenuation ratio of the area anterior to the oval window normalized to normal otic capsule bone and air. RESULTS The relative attenuation ratio for cases of otospongiosis was significantly lower than that for controls (P < .001). Based on receiver operating characteristic analysis, the optimal cutoff relative attenuation ratio was 0.876, which had an accuracy of 97.2% for the diagnosis of otospongiosis. CONCLUSIONS Internally calibrated pixel value ratios in temporal bone conebeam CT can feasibly help diagnose active/spongiotic-phase fenestral otosclerosis in an objective manner.
Collapse
Affiliation(s)
- F Deng
- From the Department of Radiology (F.D.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - P Touska
- Department of Radiology (P.T), Guy's Hospital, Guy's and St. Thomas' Hospitals National Health Service Foundation Trust, London, UK
| | - K L Reinshagen
- Department of Radiology (K.L.R, H.D.C., A.F.J.), Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - H D Curtin
- Department of Radiology (K.L.R, H.D.C., A.F.J.), Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - A F Juliano
- Department of Radiology (K.L.R, H.D.C., A.F.J.), Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
5
|
Influence of voxel size on cone beam computed tomography artifacts arising from the exomass. Oral Surg Oral Med Oral Pathol Oral Radiol 2021; 132:456-464. [PMID: 33422474 DOI: 10.1016/j.oooo.2020.12.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 11/21/2020] [Accepted: 12/05/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVES The objective of this study was to evaluate the influence of voxel size on artifacts arising from the exomass in cone beam computed tomography (CBCT). STUDY DESIGN An imaging phantom was scanned using 2 CBCT units, each adjusted to 2 voxel sizes: 0.2 and 0.3 mm. From 1 to 3 metal inserts of titanium, cobalt-chromium, or amalgam were placed in the exomass and additional CBCT scans were acquired. Mean voxel gray values were obtained from 16 homogeneous areas of the phantom and averaged, and the standard deviation was calculated to obtain voxel gray value variability. The data were analyzed using 2-way analysis of variance, Tukey, and Dunnett tests (α =.05). RESULTS Overall, mean voxel gray values and voxel gray value variability did not differ significantly between CBCT scans obtained with voxel sizes of 0.2 and 0.3 mm for either CBCT model tested (P > .05). Despite some exceptions in which significant differences were observed between the 2 voxel sizes (P < .05), the mean voxel gray values and voxel gray value variability resulting from different metal compositions and, in most situations, for different numbers of metal inserts in the exomass were not affected. CONCLUSION Voxel size has little influence on exomass-related CBCT artifacts.
Collapse
|
6
|
Molez AM, Nascimento EHL, Haiter Neto F, Cirano FR, Pimentel SP, Ribeiro FV, Casati MZ, Corrêa MG. Effect of resveratrol on the progression of experimental periodontitis in an ovariectomized rat model of osteoporosis: Morphometric, immune‐enzymatic, and gene expression analysis. J Periodontal Res 2020; 55:840-849. [DOI: 10.1111/jre.12775] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 05/13/2020] [Accepted: 05/21/2020] [Indexed: 12/23/2022]
Affiliation(s)
| | - Eduarda Helena Leandro Nascimento
- Department of Oral Diagnosis Division of Oral Radiology Piracicaba Dental School University of Campinas Piracicaba, São Paulo Brazil
| | - Francisco Haiter Neto
- Department of Oral Diagnosis Division of Oral Radiology Piracicaba Dental School University of Campinas Piracicaba, São Paulo Brazil
| | | | | | | | | | | |
Collapse
|
7
|
Gaêta-Araujo H, Nascimento EHL, Brasil DM, Madlum DV, Haiter-Neto F, Oliveira-Santos C. Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density. Imaging Sci Dent 2020; 50:153-159. [PMID: 32601590 PMCID: PMC7314611 DOI: 10.5624/isd.2020.50.2.153] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 12/12/2019] [Accepted: 12/30/2019] [Indexed: 12/17/2022] Open
Abstract
Purpose This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. Materials and Methods The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations (standard protocol; SP) for the application of artifact correction tools (beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test (α=0.05). Results The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP (P<0.05). The smoothing and RAC tools did not affect BMD values. Conclusion BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD.
Collapse
Affiliation(s)
- Hugo Gaêta-Araujo
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil
| | - Eduarda Helena Leandro Nascimento
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil
| | - Danieli Moura Brasil
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil
| | - Daniela Verardi Madlum
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil
| | - Francisco Haiter-Neto
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo, Brazil
| | - Christiano Oliveira-Santos
- Department of Stomatology, Public Oral Health, Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Sao Paulo, Brazil
| |
Collapse
|
8
|
Candemil AP, Salmon B, Freitas DQ, Haiter-Neto F, Oliveira ML. Distribution of metal artifacts arising from the exomass in small field-of-view cone beam computed tomography scans. Oral Surg Oral Med Oral Pathol Oral Radiol 2020; 130:116-125. [PMID: 32057753 DOI: 10.1016/j.oooo.2020.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Revised: 12/11/2019] [Accepted: 01/10/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVES To evaluate the distribution of metal artifacts from the exomass in small field-of-view (FOV) cone beam computed tomography (CBCT) scans. STUDY DESIGN An image phantom was scanned by using 3 CBCT units. Metal objects were positioned in the exomass, and additional CBCT scans were obtained. Mean gray values were obtained from 16 homogeneous areas and the standard deviation was calculated to quantify gray level inhomogeneity according to distinct zones of the FOV: total area and outer, inner, right, left, and mid-zones. The discrepancy between each zone and the total area was calculated to compare different CBCT units. Mean gray, gray level inhomogeneity, and discrepancy values were separately assessed by using analysis of variance (ANOVA) and Tukey's test (α = 0.05). RESULTS Overall, the mean gray values were significantly lower in the inner zone, and the gray level inhomogeneity values were significantly higher in the inner and mid-zones irrespective of the presence of metal objects in the exomass. The 3 CBCT units presented significantly different discrepancy values in most conditions. CONCLUSIONS The distribution of metal artifacts from the exomass follows the inherent gray value dispersion of CBCT images, with greater inhomogeneity in the inner zone of the FOV. This is exacerbated when metal objects are in the exomass.
Collapse
Affiliation(s)
- Amanda P Candemil
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba (São Paulo), Brazil.
| | - Benjamin Salmon
- Université de Paris, Orofacial Pathologies, Imaging and Biotherapies EA2496 Lab, Montrouge, France; Dental Medicine Department, AP-HP, Bretonneau Hospital, Paris, France
| | - Deborah Queiroz Freitas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba (São Paulo), Brazil
| | - Francisco Haiter-Neto
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba (São Paulo), Brazil
| | - Matheus Lima Oliveira
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba (São Paulo), Brazil
| |
Collapse
|
9
|
Yadav S, Sachs E, Vishwanath M, Knecht K, Upadhyay M, Nanda R, Tadinada A. Gender and growth variation in palatal bone thickness and density for mini-implant placement. Prog Orthod 2018; 19:43. [PMID: 30393829 PMCID: PMC6215790 DOI: 10.1186/s40510-018-0241-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Accepted: 09/07/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The objective was to compare the palatal bone thickness (PBT) and palatal bone density (PBD) in the anterior, middle, and posterior part of the palate in males and females. METHODS This retrospective study reviewed cone beam computed tomography scans of 359 patients. The scans were divided into 99 growing males, 105 growing females, 74 non-growing males, and 81 non-growing females. The measurements of PBT and PBD were made in between the canine and first premolar, the first premolar and second premolar, the second premolar and first molar, and the first molar and second molar. The measurements were made in the center of the palate and 4 mm away from the center. ANOVA was used to analyze the PBT and PBD in different areas between four different groups. RESULTS The PBT was lower (P < 0.0001) as we moved from the anterior to the posterior palate. The PBT was more (P < 0.001) in the center of the palate than 4 mm away from the center, except in between the canine and first premolar. The growing male and non-growing male had higher (P < 0.0001) PBT than the growing female and non-growing female in between the canine and first premolar and the first premolar and second premolar both in the center and 4 mm away from it. The PBD was higher (P < 0.05) in between the canine and first premolar area at the center of the palate and between the second premolar and first molar 4 mm away from the center in all the experimental groups. CONCLUSIONS There exists a definite gender and growth variation in the PBT and PBD in different parts of the palate. Palatal bone thickness between the males and females revealed that the males had significantly higher PBT than the females.
Collapse
Affiliation(s)
- Sumit Yadav
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA. .,School of Dental Medicine, University of Connecticut Health Center, 263 Farmington Avenue, L7062A MC1725, Farmington, CT, 06030, USA.
| | - Emily Sachs
- School of Dental Medicine, University of Connecticut Health Center, 263 Farmington Avenue, L7062A MC1725, Farmington, CT, 06030, USA
| | - Meenakshi Vishwanath
- Division of Orthodontics, University of Nebraska Medical Center, Farmington, USA
| | | | - Madhur Upadhyay
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA
| | - Ravindra Nanda
- Division of Orthodontics, University of Connecticut Health Center, Farmington, USA
| | - Aditya Tadinada
- Division of Oral Health and Diagnostic Sciences, University of Connecticut Health Center, Farmington, USA
| |
Collapse
|
10
|
Candemil AP, Salmon B, Freitas DQ, Ambrosano GM, Haiter-Neto F, Oliveira ML. Metallic materials in the exomass impair cone beam CT voxel values. Dentomaxillofac Radiol 2018; 47:20180011. [PMID: 29582689 DOI: 10.1259/dmfr.20180011] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
OBJECTIVES To assess the influence of artefacts arising from metallic materials in the exomass on cone beam CT (CBCT) voxel values. METHODS CBCT scans were taken of a phantom composed of 16 tubes filled with a homogeneous hyperdense solution and metallic materials of different compositions (titanium, cobalt-chromium and amalgam) and numbers (one, two and three). The phantom was centred in a 5 × 5 cm field of view such that the metallic materials were located in the exomass, using three CBCT units. Voxel values were obtained from the 16 homogeneous areas and averaged. Also, standard deviation was calculated to measure voxel value variability. Analysis of variance in a factorial scheme with additional treatment 3 × 3 + 3 (material × number + control) was performed, followed by Tukey's test for multiple comparisons, and Dunnett's test for comparisons with the control groups, at a level of significance of 5%. RESULTS Metallic material in the exomass significantly reduced the mean voxel value in the CS9300 and Picasso Trio units, and increased voxel value variability in all CBCT units. Amalgam was the material that induced significantly greater reduction of the mean voxel value in the CS9300 and Picasso Trio units, and significantly greater increase in the NewTom Giano. Voxel value variability was significantly greater for amalgam in all conditions. The presence of one cylinder induced significantly less pronounced effects on the mean voxel value and voxel value variability. CONCLUSIONS Artefacts arising from metallic materials in the exomass have a negative influence on CBCT voxel values.
Collapse
Affiliation(s)
- Amanda P Candemil
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Piracicaba , Brazil
| | - Benjamin Salmon
- 2 Department of Dental Medicine, Bretonneau Hospital, HUPNVS, AP-HP , Paris , France.,3 EA 2496 - Orofacial Pathologies, Imaging and Biotherapies Lab, Sorbonne Paris Cité - Paris Descartes University. , Paris , France
| | - Deborah Q Freitas
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Piracicaba , Brazil
| | - Glaucia Mb Ambrosano
- 4 Department of Community Dentistry, Piracicaba Dental School, University of Campinas , Piracicaba , Brazil
| | - Francisco Haiter-Neto
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Piracicaba , Brazil
| | - Matheus L Oliveira
- 1 Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas , Piracicaba , Brazil
| |
Collapse
|
11
|
Menezes CC, Janson G, da Silveira Massaro C, Cambiaghi L, Garib DG. Precision, reproducibility, and accuracy of bone crest level measurements of CBCT cross sections using different resolutions. Angle Orthod 2016; 86:535-542. [PMID: 26488463 PMCID: PMC8601492 DOI: 10.2319/040115-214.1] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2015] [Accepted: 09/01/2015] [Indexed: 09/08/2023] Open
Abstract
OBJECTIVE To evaluate the precision, reproducibility, and accuracy of alveolar crest level measurements on CBCT images obtained with different voxel sizes. MATERIALS AND METHODS CBCT exams were made of 12 dried human mandibles with voxel dimensions of 0.2, 0.3, and 0.4 mm. Bone crest level was measured directly on the mandibles with a digital caliper and on CBCT images. Images were measured twice by two examiners. Intra- and interexaminer precision and reproducibility were assessed using paired and t-tests, respectively. Accuracy was evaluated using t-tests. RESULTS Precision and reproducibility of bone crest level tomographic measurements was good for all voxel sizes evaluated. The images with 0.2-mm voxel size showed a decreased number of intraexaminer errors. A high accuracy for measurements of bone crest level was observed for all CBCT definitions, except for the mandibular incisors using the 0.4-mm voxel size. CONCLUSIONS Precision and reproducibility of alveolar bone level measurements were good for various voxel sizes. CBCT images demonstrated good accuracy for 0.2-mm and 0.3-mm voxel sizes. The mandibular incisor region needs better resolution than that provided by 0.4-mm voxel size for bone crest level measurements.
Collapse
Affiliation(s)
- Carolina Carmo Menezes
- Orthodontic Graduate Student, Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Guilherme Janson
- Professor, Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Camila da Silveira Massaro
- Orthodontic Graduate Student, Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Lucas Cambiaghi
- Periodontic Graduate Student, Department of Prosthodontics, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil
| | - Daniela Gamba Garib
- Associate Professor, Department of Orthodontics, Bauru Dental School, Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|