1
|
Ono Y, Akamatsu Y, Kojima D, Miyoshi K, Koji T, Kubo Y, Kashimura H, Ogasawara K. Coil embolization of recurrent ruptured vertebral artery dissection through a marathon microcatheter: A case report. Radiol Case Rep 2024; 19:2332-2336. [PMID: 38559661 PMCID: PMC10978454 DOI: 10.1016/j.radcr.2024.02.075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/17/2024] [Accepted: 02/22/2024] [Indexed: 04/04/2024] Open
Abstract
A 56-year-old healthy woman presented with subarachnoid hemorrhage caused by ruptured vertebral artery dissecting aneurysm and was treated with internal trapping of the affected site including the aneurysm. She suffered rebleeding due to recanalization of the aneurysm 5 days after the first treatment. Because of the close proximity of the coil mass to the posterior inferior cerebellar artery (PICA) origin at first treatment, additional coil embolization by tight packing of the coil mass was planned. However, navigation of the microcatheter into the coil mass was challenging due to the tightly packed coil mass. Thus, a Marathon microcatheter, which has narrower outer diameter and is designed for liquid embolization, was used and successfully placed into the coil mass in an anterograde fashion. Thereafter, the DAC was advanced just proximal to the coil mass to reduce the kickback of the microcatheter during deployment of the coils and avoid the coil mass expansion toward the PICA origin, resulting in complete obliteration of the aneurysm with PICA preservation. Follow-up angiography performed 6 months after the second treatment showed complete obliteration of the aneurysm. The patient's course was uneventful after 1 year following the second treatment, with a modified Rankin Scale score of 1. Therefore, coil embolization through the tightly packed coil mass using a Marathon microcatheter is feasible. A low-profile DAC is also useful for enabling physicians to push the coil deployed through the flexible Marathon microcatheter.
Collapse
Affiliation(s)
- Yutaro Ono
- Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan
| | - Yosuke Akamatsu
- Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan
- Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba-cho, Iwate, Japan
| | - Daigo Kojima
- Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan
| | - Kenya Miyoshi
- Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan
| | - Takahiro Koji
- Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba-cho, Iwate, Japan
| | - Yoshitaka Kubo
- Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba-cho, Iwate, Japan
| | - Hiroshi Kashimura
- Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan
| | - Kuniaki Ogasawara
- Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba-cho, Iwate, Japan
| |
Collapse
|
2
|
Fukutome K, Ohnishi H, Kuga Y, Ohnishi H. Coil Embolization of Unruptured Distal Anterior Cerebral Artery Aneurysm Using a Marathon Microcatheter. Cureus 2022; 14:e24841. [PMID: 35702456 PMCID: PMC9177230 DOI: 10.7759/cureus.24841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/09/2022] [Indexed: 11/17/2022] Open
Abstract
Marathon is rarely used in coil embolization for an aneurysm; particularly, there have been no reports about distal anterior cerebral artery aneurysms. We have reported a case of successful use of Marathon in coil embolization in case of a distal anterior cerebral artery aneurysm. The patient was an 83-year-old woman. She had undergone coil embolization for an unruptured distal anterior cerebral artery aneurysm, which was discovered by chance. Our initial approach involved the use of a combination of Traxcess and Excelsior SL-10, but the use of SL-10 could not follow Traxcess because the right anterior cerebral artery from the right internal carotid artery had a sharp bifurcation. However, by switching to a combination of TENROU and Marathon, we could access the aneurysm. We thereby decided to continue the use of Marathon in order to complete the coil embolization. In coil embolization for an aneurysm, Marathon was found to be useful, depending on the location of the aneurysm and access route.
Collapse
|