1
|
Sabalza M, Yasmin R, Barber CA, Castro T, Malamud D, Kim BJ, Zhu H, Montagna RA, Abrams WR. Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva. PLoS One 2018; 13:e0192398. [PMID: 29401479 PMCID: PMC5798782 DOI: 10.1371/journal.pone.0192398] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Accepted: 01/23/2018] [Indexed: 12/20/2022] Open
Abstract
In recent years, there have been increasing numbers of infectious disease outbreaks that spread rapidly to population centers resulting from global travel, population vulnerabilities, environmental factors, and ecological disasters such as floods and earthquakes. Some examples of the recent outbreaks are the Ebola epidemic in West Africa, Middle East respiratory syndrome coronavirus (MERS-Co) in the Middle East, and the Zika outbreak through the Americas. We have created a generic protocol for detection of pathogen RNA and/or DNA using loop-mediated isothermal amplification (LAMP) and reverse dot-blot for detection (RDB) and processed automatically in a microfluidic device. In particular, we describe how a microfluidic assay to detect HIV viral RNA was converted to detect Zika virus (ZIKV) RNA. We first optimized the RT-LAMP assay to detect ZIKV RNA using a benchtop isothermal amplification device. Then we implemented the assay in a microfluidic device that will allow analyzing 24 samples simultaneously and automatically from sample introduction to detection by RDB technique. Preliminary data using saliva samples spiked with ZIKV showed that our diagnostic system detects ZIKV RNA in saliva. These results will be validated in further experiments with well-characterized ZIKV human specimens of saliva. The described strategy and methodology to convert the HIV diagnostic assay and platform to a ZIKV RNA detection assay provides a model that can be readily utilized for detection of the next emerging or re-emerging infectious disease.
Collapse
Affiliation(s)
- Maite Sabalza
- Department of Basic Sciences, New York University College of Dentistry, New York, New York, United States of America
- * E-mail:
| | - Rubina Yasmin
- Rheonix, Inc., Ithaca, New York, United States of America
| | - Cheryl A. Barber
- Department of Basic Sciences, New York University College of Dentistry, New York, New York, United States of America
| | - Talita Castro
- Department of Basic Sciences, New York University College of Dentistry, New York, New York, United States of America
- Stomatology Department, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil
| | - Daniel Malamud
- Department of Basic Sciences, New York University College of Dentistry, New York, New York, United States of America
- Department of Medicine, New York University School of Medicine, New York, New York, United States of America
| | - Beum Jun Kim
- Rheonix, Inc., Ithaca, New York, United States of America
| | - Hui Zhu
- Rheonix, Inc., Ithaca, New York, United States of America
| | | | - William R. Abrams
- Department of Basic Sciences, New York University College of Dentistry, New York, New York, United States of America
| |
Collapse
|
2
|
Yasmin R, Zhu H, Chen Z, Montagna RA. A modifiable microarray-based universal sensor: providing sample-to-results automation. Heliyon 2016; 2:e00179. [PMID: 27812551 PMCID: PMC5078625 DOI: 10.1016/j.heliyon.2016.e00179] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 09/22/2016] [Accepted: 10/11/2016] [Indexed: 12/30/2022] Open
Abstract
A microfluidic system consisting of generic single use cartridges which interface with a workstation allows the automatic performance of all necessary sample preparation, PCR analysis and interpretation of multiplex PCR assays. The cartridges contain a DNA array with 20 different 16mer DNA “universal” probes immobilized at defined locations. PCR amplicons can be detected via hybridization of user-defined “reporter” probes that are complementary at their 3′ termini to one or more of the universal probes and complementary to the target amplicons at their 5′ termini. The system was able to detect single-plex and multiplex PCR amplicons from various infectious agents as well as wild type and mutant alleles of single nucleotide polymorphisms. The system's ease of use was further demonstrated by converting a published PCR assay for the detection of Mycobacterium genitalium in a fully automated manner. Excellent correlation between traditional manual methods and the automated analysis performed by the workstation suggests that the system can provide a means to easily design and implement a variety of customized PCR-based assays. The system will be useful to researchers or clinical investigators seeking to develop their own user defined assays. As the U.S. FDA continues to pursue regulatory oversight of LDTs, the system would also allow labs to continue to develop compliant assays.
Collapse
Affiliation(s)
| | - Hui Zhu
- Rheonix Inc., 10 Brown Road, Ithaca, NY 14850, USA
| | - Zongyuan Chen
- Rheonix Inc., 10 Brown Road, Ithaca, NY 14850, USA; Thermo Fisher Scientific, South San Francisco, CA, USA
| | | |
Collapse
|
3
|
Comparison of a rapid point-of-care and two laboratory-based CYP2C19*2 genotyping assays for personalisation of antiplatelet therapy. Int J Clin Pharm 2016; 38:414-20. [DOI: 10.1007/s11096-016-0269-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Accepted: 02/25/2016] [Indexed: 10/22/2022]
|