1
|
Quality Assurance Considerations in Radiopharmaceutical Therapy Dosimetry Using PLANETDose: An International Atomic Energy Agency Study. J Nucl Med 2024; 65:125-131. [PMID: 37884334 PMCID: PMC10755524 DOI: 10.2967/jnumed.122.265340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 07/25/2023] [Indexed: 10/28/2023] Open
Abstract
Implementation of radiopharmaceutical therapy dosimetry varies depending on the clinical application, dosimetry protocol, software, and ultimately the operator. Assessing clinical dosimetry accuracy and precision is therefore a challenging task. This work emphasizes some pitfalls encountered during a structured analysis, performed on a single-patient dataset consisting of SPECT/CT images by various participants using a standard protocol and clinically approved commercial software. Methods: The clinical dataset consisted of the dosimetric study of a patient administered with [177Lu]Lu-DOTATATE at Tygerberg Hospital, South Africa, as a part of International Atomic Energy Agency-coordinated research project E23005. SPECT/CT images were acquired at 5 time points postinjection. Patient and calibration images were reconstructed on a workstation, and a calibration factor of 122.6 Bq/count was derived independently and provided to the participants. A standard dosimetric protocol was defined, and PLANETDose (version 3.1.1) software was installed at 9 centers to perform the dosimetry of 3 treatment cycles. The protocol included rigid image registration, segmentation (semimanual for organs, activity threshold for tumors), and dose voxel kernel convolution of activity followed by absorbed dose (AD) rate integration to obtain the ADs. Iterations of the protocol were performed by participants individually and within collective training, the results of which were analyzed for dosimetric variability, as well as for quality assurance and error analysis. Intermediary checkpoints were developed to understand possible sources of variation and to differentiate user error from legitimate user variability. Results: Initial dosimetric results for organs (liver and kidneys) and lesions showed considerable interoperator variability. Not only was the generation of intermediate checkpoints such as total counts, volumes, and activity required, but also activity-to-count ratio, activity concentration, and AD rate-to-activity concentration ratio to determine the source of variability. Conclusion: When the same patient dataset was analyzed using the same dosimetry procedure and software, significant disparities were observed in the results despite multiple sessions of training and feedback. Variations due to human error could be minimized or avoided by performing intensive training sessions, establishing intermediate checkpoints, conducting sanity checks, and cross-validating results across physicists or with standardized datasets. This finding promotes the development of quality assurance in clinical dosimetry.
Collapse
|
2
|
ASSESSMENT OF THE OUTDOOR GAMMA RADIATION LEVELS IN ALGIERS PROVINCE, ALGERIA. RADIATION PROTECTION DOSIMETRY 2021; 194:144-152. [PMID: 34164691 DOI: 10.1093/rpd/ncab090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 05/04/2021] [Accepted: 05/24/2021] [Indexed: 06/13/2023]
Abstract
The outdoor gamma radiation dose rates due to natural radioactivity and due to the artificial radionuclides released from the Chernobyl and Fukushima accidents and Algeciras incident were assessed in the Algiers province (capital of Algeria). Furthermore, the dose rates induced by the cosmic rays were analytically calculated in the province concerned. The recorded dose rates due to terrestrial outdoor gamma radiation were found to range from 14.3 ± 0.7 to 114.3 ± 5.7 nGy h -1, those due to cosmic rays ranged from 32.021 ± 0.013 to 34.029 ± 0.367 nGy h -1, while the contribution of the dose rate due to external exposure induced by 137Cs deposits, from major accidents, was estimated to be less than 0.3 nGy h-1. The spatial distributions of terrestrial and cosmic rays dose rates were mapped using QGIS software. The obtained radiological baseline maps can be used as reference information to assess any changes in the radiation exposure levels having an impact on the population health.
Collapse
|
3
|
An unknown source of reactor radionuclides in the Baltic Sea revealed by multi-isotope fingerprints. Nat Commun 2021; 12:823. [PMID: 33547296 PMCID: PMC7865023 DOI: 10.1038/s41467-021-21059-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Accepted: 01/11/2021] [Indexed: 11/25/2022] Open
Abstract
We present an application of multi-isotopic fingerprints (i.e., 236U/238U, 233U/236U, 236U/129I and 129I/127I) for the discovery of previously unrecognized sources of anthropogenic radioactivity. Our data indicate a source of reactor 236U in the Baltic Sea in addition to inputs from the two European reprocessing plants and global fallout. This additional reactor 236U may come from unreported discharges from Swedish nuclear research facilities as supported by high 236U levels in sediment nearby Studsvik, or from accidental leakages of spent nuclear fuel disposed on the Baltic seafloor, either reported or unreported. Such leakages would indicate problems with the radiological safety of seafloor disposal, and may be accompanied by releases of other radionuclides. The results demonstrate the high sensitivity of multi-isotopic tracer systems, especially the 233U/236U signature, to distinguish environmental emissions of unrevealed radioactive releases for nuclear safeguards, emergency preparedness and environmental tracer studies. Anthropogenic activities lead to the accumulation of radioactive substances in the environment. Here the authors use multi-isotopic fingerprints of uranium and iodine to discover a previously unknown source of reactor uranium in the Baltic Sea, likely sourced from a Swedish nuclear facility.
Collapse
|
4
|
Laboratory Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range. REMOTE SENSING 2019. [DOI: 10.3390/rs11091101] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly effective. Distinct radiometers from different manufacturers operated by different scientists can yield quite close radiance and irradiance results (standard deviation s < 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertainty of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
Collapse
|
5
|
Tartrate-resistant acid phosphatase (TRAP/ACP5) promotes metastasis-related properties via TGFβ2/TβR and CD44 in MDA-MB-231 breast cancer cells. BMC Cancer 2017; 17:650. [PMID: 28915803 PMCID: PMC5602878 DOI: 10.1186/s12885-017-3616-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Accepted: 08/28/2017] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Tartrate-resistant acid phosphatase (TRAP/ACP5), a metalloenzyme that is characteristic for its expression in activated osteoclasts and in macrophages, has recently gained considerable focus as a driver of metastasis and was associated with clinically relevant parameters of cancer progression and cancer aggressiveness. METHODS MDA-MB-231 breast cancer cells with different TRAP expression levels (overexpression and knockdown) were generated and characterized for protein expression and activity levels. Functional cell experiments, such as proliferation, migration and invasion assays were performed as well as global phosphoproteomic and proteomic analysis was conducted to connect molecular perturbations to the phenotypic changes. RESULTS We identified an association between metastasis-related properties of TRAP-overexpressing MDA-MB-231 breast cancer cells and a TRAP-dependent regulation of Transforming growth factor (TGFβ) pathway proteins and Cluster of differentiation 44 (CD44). Overexpression of TRAP increased anchorage-independent and anchorage-dependent cell growth and proliferation, induced a more elongated cellular morphology and promoted cell migration and invasion. Migration was increased in the presence of the extracellular matrix (ECM) proteins osteopontin and fibronectin and the basement membrane proteins collagen IV and laminin I. TRAP-induced properties were reverted upon shRNA-mediated knockdown of TRAP or treatment with the small molecule TRAP inhibitor 5-PNA. Global phosphoproteomics and proteomics analyses identified possible substrates of TRAP phosphatase activity or signaling intermediates and outlined a TRAP-dependent regulation of proteins involved in cell adhesion and ECM organization. Upregulation of TGFβ isoform 2 (TGFβ2), TGFβ receptor type 1 (TβR1) and Mothers against decapentaplegic homolog 2 (SMAD2), as well as increased intracellular phosphorylation of CD44 were identified upon TRAP perturbation. Functional antibody-mediated blocking and chemical inhibition demonstrated that TRAP-dependent migration and proliferation is regulated via TGFβ2/TβR, whereas proliferation beyond basal levels is regulated through CD44. CONCLUSION Altogether, TRAP promotes metastasis-related cell properties in MDA-MB-231 breast cancer cells via TGFβ2/TβR and CD44, thereby identifying a potential signaling mechanism associated to TRAP action in breast cancer cells.
Collapse
|
6
|
Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification: An IAEA phantom study. Z Med Phys 2016; 27:98-112. [PMID: 27105765 DOI: 10.1016/j.zemedi.2016.03.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 03/07/2016] [Accepted: 03/30/2016] [Indexed: 10/21/2022]
Abstract
Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing 133Ba, which was chosen as a surrogate for 131I. The sources, with nominal volumes of 2, 4, 6 and 23mL, were calibrated for 133Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to about 6% with planar imaging and SPECT (with Chang-AC) and within 2% for SPECT-CT.
Collapse
|
7
|
An Interlaboratory Comparison of Sizing and Counting of Subvisible Particles Mimicking Protein Aggregates. J Pharm Sci 2015; 104:666-77. [DOI: 10.1002/jps.24287] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2014] [Revised: 10/30/2014] [Accepted: 11/03/2014] [Indexed: 01/15/2023]
|
8
|
|
9
|
Re-evaluation of the product of (W/e)airand the graphite to air stopping-power ratio for60Co air kerma standards. Phys Med Biol 2010; 55:3577-95. [DOI: 10.1088/0031-9155/55/13/001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
10
|
Intercomparison of Rn-222 determination from groundwater. Appl Radiat Isot 2010; 68:214-8. [DOI: 10.1016/j.apradiso.2009.10.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Revised: 10/07/2009] [Accepted: 10/08/2009] [Indexed: 11/18/2022]
|
11
|
Comprehensive inter-laboratory calibration of reference materials for delta18O versus VSMOW using various on-line high-temperature conversion techniques. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:999-1019. [PMID: 19263478 DOI: 10.1002/rcm.3958] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125 per thousand, an artificially enriched reference water (delta(18)O of +78.91 per thousand) and two barium sulfates (one depleted and one enriched in (18)O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material delta(18)O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 +/- 0.36 per thousand USGS 35 sodium nitrate+56.81 +/- 0.31 per thousand IAEA-NO-3 potassium nitrate+25.32 +/- 0.29 per thousand IAEA-601 benzoic acid+23.14 +/- 0.19 per thousand IAEA-SO-5 barium sulfate+12.13 +/- 0.33 per thousand NBS 127 barium sulfate+8.59 +/- 0.26 per thousand VSMOW2 water 0 per thousand IAEA-600 caffeine-3.48 +/- 0.53 per thousand IAEA-SO-6 barium sulfate-11.35 +/- 0.31 per thousand USGS 34 potassium nitrate-27.78 +/- 0.37 per thousand SLAP water-55.5 per thousand The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for delta(18)O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (delta(18)O) of nitrates, sulfates, or organic material should explicitly state in their reports the delta(18)O values of two or more internationally distributed nitrates (USGS 34, IAEA-NO-3, and USGS 35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the delta(18)O values at a later time should it become necessary.The high-temperature reduction technique for analyzing delta(18)O and delta(2)H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.
Collapse
|
12
|
Differential quantitative proteomics of Porphyromonas gingivalis by linear ion trap mass spectrometry: non-label methods comparison, q-values and LOWESS curve fitting. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2007; 259:105-116. [PMID: 19337574 PMCID: PMC2662607 DOI: 10.1016/j.ijms.2006.08.004] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Differential analysis of whole cell proteomes by mass spectrometry has largely been applied using various forms of stable isotope labeling. While metabolic stable isotope labeling has been the method of choice, it is often not possible to apply such an approach. Four different label free ways of calculating expression ratios in a classic "two-state" experiment are compared: signal intensity at the peptide level, signal intensity at the protein level, spectral counting at the peptide level, and spectral counting at the protein level. The quantitative data were mined from a dataset of 1245 qualitatively identified proteins, about 56% of the protein encoding open reading frames from Porphyromonas gingivalis, a Gram-negative intracellular pathogen being studied under extracellular and intracellular conditions. Two different control populations were compared against P. gingivalis internalized within a model human target cell line. The q-value statistic, a measure of false discovery rate previously applied to transcription microarrays, was applied to proteomics data. For spectral counting, the most logically consistent estimate of random error came from applying the locally weighted scatter plot smoothing procedure (LOWESS) to the most extreme ratios generated from a control technical replicate, thus setting upper and lower bounds for the region of experimentally observed random error.
Collapse
|
13
|
Abstract
A simple and intuitive graphical method is presented for producing a summary overview of experimental results of a common measurand, e.g. in the frame of an intercomparison. The PomPlots display (relative) deviations of individual results from the consensus value on the horizontal axis and (relative) uncertainties on the vertical axis. The z-scores, z=1, 2 and 3, are represented by diagonal lines, creating the aspect of a pyramidal structure. The most accurate and precise measurement results should be situated close to the top of the pyramid. The plots are used to visualise data from the BIPM key comparison database on primary radioactivity measurements.
Collapse
|
14
|
|
15
|
Quantitative proteomics of the archaeon Methanococcus maripaludis validated by microarray analysis and real time PCR. Mol Cell Proteomics 2006; 5:868-81. [PMID: 16489187 PMCID: PMC2655211 DOI: 10.1074/mcp.m500369-mcp200] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
For the archaeon Methanococcus maripaludis, a fully sequenced and annotated model species of hydrogenotrophic methanogen, we report validation of quantitative protein level expression ratios on a proteome-wide basis. Using an approach based on quantitative multidimensional capillary HPLC and quadrupole ion trap mass spectrometry, coverage of gene expression approached that currently achievable with transcription microarrays. Comprehensive mass spectrometry-based proteomics and spotted cDNA arrays were used to compare global protein and mRNA levels in a wild-type (S2) and mutant strain (S40) of M. maripaludis. Using linear regression with 652 expression ratios generated by both the proteomic and microarray methods, a product moment correlation coefficient of 0.24 was observed. The correlation improved to 0.61 if only genes showing significant expression changes were included. A novel two-stage method of outlier detection was used for the protein measurements when Dixon's Q-test by itself failed to give satisfactory results. The log(2) transformations of the number of peptides or isotopic peptide pairs associated with each ORF, divided by the predicted molecular weight, were found to have moderately positive correlations with two bioinformatic predictors of gene expression based on codon bias. We detected peptides derived from 939 proteins or 55% of the genome coding capacity. Of these, 60 were overexpressed, and 34 were underexpressed in the mutant. Of the 1722 ORFs encoded in the genome, 1597 or 93% were probed by cDNA arrays. Of these, 50 were more highly expressed, and 45 showed lower expression levels in the mutant relative to the wild type. 15 ORFs were shown to be overexpressed by both methods, and two ORFs were shown to be overexpressed by proteomics and underexpressed by microarray.
Collapse
|
16
|
Possible new definitions of the kilogram. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2005; 363:2249-64. [PMID: 16147508 DOI: 10.1098/rsta.2005.1637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The kilogram is the unit of mass in the International System. Its definition dates from 1889 and, therefore, predates most of modern physics. The definition simply states that the 'kilogram' is the mass of an object known as the international prototype. Thus, we have the extraordinary situation that certain fundamental physical constants (the Planck constant, the Newtonian constant of gravitation, the mass of an electron, the mass of an atom of carbon-12, etc.) are measured in terms of an artefact that was manufactured in the nineteenth century. We begin by describing what is presently known about the long-term stability of artefact standards and how this stability can be experimentally monitored with respect to fundamental constants of physics. Finally, we suggest that present experiments are close to achieving the target uncertainty of the order 10(-8), although the current incoherence between two classes of experiments is cause for concern.
Collapse
|
17
|
A dynamic, web-accessible resource to process raw microarray scan data into consolidated gene expression values: importance of replication. Nucleic Acids Res 2004; 32:5349-58. [PMID: 15475389 PMCID: PMC524282 DOI: 10.1093/nar/gkh870] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
We propose a freely accessible web-based pipeline, which processes raw microarray scan data to obtain experimentally consolidated gene expression values. The tool MADSCAN, which stands for MicroArray Data Suites of Computed ANalysis, makes a practical choice among the numerous methods available for filtering, normalizing and scaling of raw microarray expression data in a dynamic and automatic way. Different statistical methods have been adapted to extract reliable information from replicate gene spots as well as from replicate microarrays for each biological situation under study. A carefully constructed experimental design thus allows to detect outlying expression values and to identify statistically significant expression values, together with a list of quality controls with proposed threshold values. The integrated processing procedure described here, based on multiple measurements per gene, is decisive for reliably monitoring subtle gene expression changes typical for most biological events.
Collapse
|
18
|
Abstract
The problem of evaluating discrepant data has been addressed by several authors over the previous 20 yr. More recently some attention has been given to the use of the median, which is expected to have better statistical 'robustness'. The various evaluation techniques should converge towards the 'true' value as the number of data in a data set increases, and the 'robustness' of each evaluation technique can then be tested by the rate at which that technique converges. Several evaluation techniques have been applied to discrepant data sets, and the results are shown to converge as the size of the data set grows. The discrepant data sets used as examples are the measured half-lives of 90Sr and 137Cs. Differences in the behaviour of the evaluation techniques are discussed, as applied to these data sets. The half-lives deduced from this study are: 90Sr 10,551+/-14 days; 137Cs 10,981+/-11 days.
Collapse
|
19
|
Comprehensive Review and Critical Evaluation of the Half-Life of Tritium. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY 2000; 105:541-9. [PMID: 27551621 PMCID: PMC4877155 DOI: 10.6028/jres.105.043] [Citation(s) in RCA: 106] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 07/27/2000] [Indexed: 05/05/2023]
Abstract
As part of the preparation and calibration of three new National Institute of Standards and Technology (NIST) tritiated-water radioactivity Standard Reference Materials (SRMs), we have performed a comprehensive review and critical evaluation of the half-life of tritium (hydrogen-3). Twenty three experimentally-determined values of the half-life of tritium, reported between 1936 and 2000, were found. Six of these values were updated by later values. Two values were limits. Two values were deemed to be outliers. The 13 remaining values were evaluated in several ways. The results are compared with the results of other recent evaluations and all are found to be in good agreement. Our final recommended value for the half-life of tritium is the average of the adopted values from the four most recent evaluations, (4500 ± 8) d, where 8 d corresponds to one standard uncertainty.
Collapse
|