1
|
IOeRT conventional and FLASH treatment planning system implementation exploiting fast GPU Monte Carlo: The case of breast cancer. Phys Med 2024; 121:103346. [PMID: 38608421 DOI: 10.1016/j.ejmp.2024.103346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/13/2024] [Accepted: 04/01/2024] [Indexed: 04/14/2024] Open
Abstract
Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms. The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account. The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.
Collapse
|
2
|
Adaptable test bench for ASTM-compliant permeability measurement of porous scaffolds for tissue engineering. Sci Rep 2024; 14:1722. [PMID: 38242930 PMCID: PMC10799031 DOI: 10.1038/s41598-024-52159-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 01/15/2024] [Indexed: 01/21/2024] Open
Abstract
Intrinsic permeability describes the ability of a porous medium to be penetrated by a fluid. Considering porous scaffolds for tissue engineering (TE) applications, this macroscopic variable can strongly influence the transport of oxygen and nutrients, the cell seeding process, and the transmission of fluid forces to the cells, playing a crucial role in determining scaffold efficacy. Thus, accurately measuring the permeability of porous scaffolds could represent an essential step in their optimization process. In literature, several methods have been proposed to characterize scaffold permeability. Most of the currently adopted approaches to assess permeability limit their applicability to specific scaffold structures, hampering protocols standardization, and ultimately leading to incomparable results among different laboratories. The content of novelty of this study is in the proposal of an adaptable test bench and in defining a specific testing protocol, compliant with the ASTM International F2952-22 guidelines, for reliable and repeatable measurements of the intrinsic permeability of TE porous scaffolds. The developed permeability test bench (PTB) exploits the pump-based method, and it is composed of a modular permeability chamber integrated within a closed-loop hydraulic circuit, which includes a peristaltic pump and pressure sensors, recirculating demineralized water. A specific testing protocol was defined for characterizing the pressure drop associated with the scaffold under test, while minimizing the effects of uncertainty sources. To assess the operational capabilities and performance of the proposed test bench, permeability measurements were conducted on PLA scaffolds with regular (PS) and random (RS) micro-architecture and on commercial bovine bone matrix-derived scaffolds (CS) for bone TE. To validate the proposed approach, the scaffolds were as well characterized using an alternative test bench (ATB) based on acoustic measurements, implementing a blind randomized testing procedure. The consistency of the permeability values measured using both the test benches demonstrated the reliability of the proposed approach. A further validation of the PTB's measurement reliability was provided by the agreement between the measured permeability values of the PS scaffolds and the theory-based predicted permeability value. Once validated the proposed PTB, the performed measurements allowed the investigation of the scaffolds' transport properties. Samples with the same structure (guaranteed by the fused-deposition modeling technique) were characterized by similar permeability values, and CS and RS scaffolds showed permeability values in agreement with the values reported in the literature for bovine trabecular bone. In conclusion, the developed PTB and the proposed testing protocol allow the characterization of the intrinsic permeability of porous scaffolds of different types and dimensions under controlled flow regimes, representing a powerful tool in view of providing a reliable and repeatable framework for characterizing and optimizing scaffolds for TE applications.
Collapse
|
3
|
New Advantage in Stereotactic Treatment of Lung and Pancreatic Cancer. Performance of Ultra-High Energy Electron (VHEE) Therapy Adjuvanted to the FLASH Effect: Clinical Implications and Treatment Plans Analysis. Int J Radiat Oncol Biol Phys 2023; 117:e648-e649. [PMID: 37785927 DOI: 10.1016/j.ijrobp.2023.06.2068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) Very High-Energy Electron (VHEE) beams delivered at ultra-high dose rates and hence profiting from the FLASH effect, may be a viable alternative to conventional treatment plans for the treatment of deep-seated tumors. Experimental data support the evidence of a considerable normal tissue sparing effect when treatments are delivered with dose rates much larger (100 times or more) compared to the conventional ones. Lung cancer and pancreatic cancer are considered the two biggest cancer killers. We urgently need more research in these areas, more awareness that support improvement in treatment strategies. To evaluate the potential of FLASH VHEE irradiation in these two clinical situations, we investigated the achievable sparing of healthy tissues and critical dose-limiting structures, with the goal of performing a higher dose prescription. MATERIALS/METHODS The study on the potential of VHEE for the stereotactic treatment of pancreatic and lung lesions was carried out on two clinical cases treated with Volumetric Modulated Arc Therapy (VMAT) techniques at University Hospital Campus Bio-Medico of Rome. The Planning Target Volume (PTV) was identified and the constraints on the Organs at Risk (OAR) and details on the irradiation approach were defined. The VHEE plan was designed to optimize the dose delivery to best activate the modelled FLASH effect based on the current experimental knowledge. In particular the impact on a dose threshold to activate the effect was studied. The VHEE treatment plan was based on an accurate Monte Carlo simulation of the electrons interactions and the results achievable with different FLASH effect models were studied. The simulation allowed the estimation of dose maps, which were used as input to an optimization algorithm that modified the fluence of each beam to meet treatment prescriptions in terms of dose to PTV. At the end the VHEE DVH plans were compared to VMAT plans. RESULTS The results demonstrated that FLASH therapy with VHEE beams of 70-130 MeV, could represent a promising alternative to standard radiotherapy allowing a comparable sparing of the healthy tissues. In the case of pancreatic cancer, the Dose Volume Histograms (DVH) showed how such a technique can be effective in sparing the duodenum. In case of lung cancers, the result showed how pulmonary tissue sparing can lead to a substantial reduction of pulmonary toxicity in comparison with the VMAT technique. CONCLUSION In the case of pancreatic cancer and assuming a non-negligible contribution from the FLASH effect, the DVH showed how the duodenum healthy tissue sparing could allow a higher dose to be prescribed at the target while keeping the constraints respected, improving the therapeutic ratio. In the case of lung cancer, the advantages of the technique are additionally increased by the significant benefit that could be related to the treatment delivery time reduction (<1s) and to the corresponding advantage coming from a reduced organ movement that translates in a lower risk of lung toxicity.
Collapse
|
4
|
Investigation of the impact of additive manufacturing techniques on the acoustic performance of a coiled-up resonator. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:2921. [PMID: 37191473 DOI: 10.1121/10.0019474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 05/02/2023] [Indexed: 05/17/2023]
Abstract
Acoustic metamaterials (AMMs) offer innovative solutions for physics and engineering problems, allowing lighter, multiphysics, and sustainable systems. They are usually studied analytically or numerically and then tested on prototypes. For this reason, additive manufacturing (AM) techniques are a popular way of quickly realising AMMs' innovative geometrical designs. However, AM parameters are often standardised without considering the specific issues of each AMM geometrical shape, leading to a possible mismatch between the analytical (or numerical) and experimental results. In this study, a simple AMM-a coiled-up resonator-has been produced with different AM technologies [fused deposition modeling (FDM), stereolithography (SLA), and selective laser melting and materials (polylactic acid, polyethylene terephthalate glycol, resin, flexible resin, and stainless steel). The sound absorption performance of these samples has been measured in two research labs in Italy and compared with the analytical and numerical calculations. This permitted the identification of the best combinations of AM technologies, their setup, and materials matching the expected results. The SLA/resin combination performed better overall; however, cheaper and more easily manageable samples made with FDM and polyethylene terephthalate glycol can achieve the same acoustic performance through the optimal AM printing setup. It is expected that this methodology could also be replicated for other AMMs.
Collapse
|
5
|
GPU-accelerated Monte Carlo simulation of electron and photon interactions for radiotherapy applications. Phys Med Biol 2023; 68. [PMID: 36356308 DOI: 10.1088/1361-6560/aca1f2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 11/10/2022] [Indexed: 11/12/2022]
Abstract
Objective. The Monte Carlo simulation software is a valuable tool in radiation therapy, in particular to achieve the needed accuracy in the dose evaluation for the treatment plans optimisation. The current challenge in this field is the time reduction to open the way to many clinical applications for which the computational time is an issue. In this manuscript we present an innovative GPU-accelerated Monte Carlo software for dose valuation in electron and photon based radiotherapy, developed as an update of the FRED (Fast paRticle thErapy Dose evaluator) software.Approach. The code transports particles through a 3D voxel grid, while scoring their energy deposition along their trajectory. The models of electromagnetic interactions in the energy region between 1 MeV-1 GeV available in literature have been implemented to efficiently run on GPUs, allowing to combine a fast tracking while keeping high accuracy in dose assessment. The FRED software has been bench-marked against state-of-art full MC (FLUKA, GEANT4) in the realm of two different radiotherapy applications: Intra-Operative Radio Therapy and Very High Electron Energy radiotherapy applications.Results. The single pencil beam dose-depth profiles in water as well as the dose map computed on non-homogeneous phantom agree with full-MCs at 2% level, observing a gain in processing time from 200 to 5000.Significance. Such performance allows for computing a plan with electron beams in few minutes with an accuracy of ∼%, demonstrating the FRED potential to be adopted for fast plan re-calculation in photon or electron radiotherapy applications.
Collapse
|
6
|
Highly Reliable Multicomponent MEMS Sensor for Predictive Maintenance Management of Rolling Bearings. MICROMACHINES 2023; 14:376. [PMID: 36838075 PMCID: PMC9962216 DOI: 10.3390/mi14020376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/20/2023] [Accepted: 01/27/2023] [Indexed: 06/18/2023]
Abstract
In the field of vibration monitoring and control, the use of low-cost multicomponent MEMS-based accelerometer sensors is nowadays increasingly widespread. Such sensors allow implementing lightweight monitoring systems with low management costs, low power consumption and a small size. However, for the monitoring systems to provide trustworthy and meaningful data, the high accuracy and reliability of sensors are essential requirements. Consequently, a metrological approach to the calibration of multi-component accelerometer sensors, including appropriate uncertainty evaluations, are necessary to guarantee traceability and reliability in the frequency domain of data provided, which nowadays is not fully available. In addition, recently developed metrological characterizations at the microscale level allow to provide detailed and accurate quantification of the enhanced technical performance and the responsiveness of these sensors. In this paper, a dynamic calibration procedure is applied to provide the sensitivity parameters of a low-cost, multicomponent MEMS sensor accelerometer prototype (MDUT), designed, developed and realized at the University of Siena, conceived for rolling bearings vibration monitoring in a broad frequency domain (from 10 Hz up to 25 kHz). The calibration and the metrological characterization of the MDUT are carried out by comparison to a reference standard transducer, at the Primary Vibration Laboratory of the National Institute of Metrological Research (INRiM).
Collapse
|
7
|
High-reliability data processing and calculation of microstructural parameters in hydroxyapatite scaffolds produced by vat photopolymerization. Ann Ital Chir 2022. [DOI: 10.1016/j.jeurceramsoc.2022.06.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
PD-0897 In vivo verification by detection of charged fragments in carbon ion therapy treatments at CNAO. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)02976-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
OC-0279 FlashDC project: development of a beam monitor for FLASH therapy. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)02537-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
A PRELIMINARY STUDY ON RADIATION PROTECTION REQUIREMENTS FOR A FLASH IOERT LINAC. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01669-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
11
|
A FEASIBILITY STUDY OF DEEP SEATED TUMOR TREATMENTS COMBINING FLASH EFFECT AND VERY HIGH ENERGY ELECTRON BEAMS. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01651-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
12
|
|
13
|
FLASH Mechanisms Track (Oral Presentations) A FEASIBILITY STUDY OF IORT-FLASH USING A GPU-BASED FAST MONTE CARLO. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01515-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
14
|
Functional mechanical attributes of natural and synthetic gel-based scaffolds in tissue engineering: strain-stiffening effects on apparent elastic modulus and compressive toughness. J Mech Behav Biomed Mater 2022; 126:105066. [PMID: 35008012 DOI: 10.1016/j.jmbbm.2021.105066] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 12/14/2021] [Accepted: 12/24/2021] [Indexed: 12/18/2022]
Abstract
The accurate identification and determination of elastic modulus and toughness, as well as other functional mechanical attributes of artificial tissues, are of paramount importance in several fields of tissue science, tissue engineering and technology, since biomechanical and biophysical behavior is strongly linked to biological features of the medical implants and tissue-engineering scaffolds. When soft or ultra-soft materials are investigated, a relevant dispersion of elastic modulus values can be achieved, due to the strain-stiffening effects, inducing a typical non-linear behavior of these materials, as a function of strain-range. In this short communication, the Apparent elastic modulus strain-range dependence is estimated from a segmentation of the strain stiffening curve, and the related compressive toughness is investigated and discussed, based on experimental evidence, for 6 different kinds of gels, used for artificial tissue fabrication; experimental results are compared to mechanical properties of native human tissues.
Collapse
|
15
|
A fully automated pipeline for log file based dose recalculation using an independent GPU-accelerated Monte Carlo in proton therapy. Phys Med 2021. [DOI: 10.1016/s1120-1797(22)00093-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
16
|
Comprehensive assessment of bioactive glass and glass-ceramic scaffold permeability: experimental measurements by pressure wave drop, modelling and computed tomography-based analysis. Acta Biomater 2021; 119:405-418. [PMID: 33091624 DOI: 10.1016/j.actbio.2020.10.027] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 10/10/2020] [Accepted: 10/14/2020] [Indexed: 10/23/2022]
Abstract
Proper microstructural and transport properties are fundamental requirements for a suitable scaffold design and realization in tissue engineering applications. Scaffold microstructure (i.e. pore size, shape and distribution) and transport properties (i.e. intrinsic permeability), are commonly recognized as the key parameters related to the biological performance, such as cell attachment, penetration depth and tissue vascularization. While pore characteristics are relatively easy to asses, accurate and reliable evaluation of permeability still remains a challenge. In the present study, the microstructural properties of foam-replicated bioactive glass-derived scaffolds (basic composition 47.5SiO2-2.5P2O5-20CaO-10MgO-10Na2O-10K2O mol.%) were determined as function of the sintering temperature within the range 600-850°C, identified on the basis of thermal analyses that were previously performed on the material. Scaffolds with total porosity between 55 and 84 vol.% and trabecular-like architecture were obtained, with pore morphological features varying according to the sintering temperature. Mathematical modelling, supported by micro-computed tomography (μ-CT) imaging, was implemented to selectively investigate the effect of different pore features on intrinsic permeability, which was determined by laminar airflow alternating pressure wave drop measurements and found to be within 0.051-2.811·10-10 m2. The calculated effective porosity of the scaffolds was in the range of 46 to 66 vol.%, while the average pore diameter assessed by μ-CT varied between 220 and 780 μm, where the values in the lower range were observed for higher sintering temperatures (750-850°C). Experimental results were critically discussed by means of a robust statistical analysis. Finally, the complete microstructural characterization of the scaffolds was achieved by applying the general constitutive equation based on Forchheimer's theory.
Collapse
|
17
|
Inter-fractional monitoring of [Formula: see text]C ions treatments: results from a clinical trial at the CNAO facility. Sci Rep 2020; 10:20735. [PMID: 33244102 PMCID: PMC7693236 DOI: 10.1038/s41598-020-77843-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 11/13/2020] [Indexed: 12/26/2022] Open
Abstract
The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.
Collapse
|
18
|
Measurement of 12C Fragmentation Cross Sections on C, O, and H in the Energy Range of Interest for Particle Therapy Applications. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2020.2972197] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
19
|
Quantitative phase contrast imaging of a shock-wave with a laser-plasma based X-ray source. Sci Rep 2019; 9:18805. [PMID: 31827132 PMCID: PMC6906500 DOI: 10.1038/s41598-019-55074-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 11/06/2019] [Indexed: 12/02/2022] Open
Abstract
X-ray phase contrast imaging (XPCI) is more sensitive to density variations than X-ray absorption radiography, which is a crucial advantage when imaging weakly-absorbing, low-Z materials, or steep density gradients in matter under extreme conditions. Here, we describe the application of a polychromatic X-ray laser-plasma source (duration ~0.5 ps, photon energy >1 keV) to the study of a laser-driven shock travelling in plastic material. The XPCI technique allows for a clear identification of the shock front as well as of small-scale features present during the interaction. Quantitative analysis of the compressed object is achieved using a density map reconstructed from the experimental data.
Collapse
|
20
|
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 16O ion beams in a PMMA target at large angles. Phys Med 2019; 64:45-53. [PMID: 31515035 DOI: 10.1016/j.ejmp.2019.06.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 05/23/2019] [Accepted: 06/07/2019] [Indexed: 11/27/2022] Open
Abstract
Particle therapy is a therapy technique that exploits protons or light ions to irradiate tumor targets with high accuracy. Protons and 12C ions are already used for irradiation in clinical routine, while new ions like 4He and 16O are currently being considered. Despite the indisputable physical and biological advantages of such ion beams, the planning of charged particle therapy treatments is challenged by range uncertainties, i.e. the uncertainty on the position of the maximal dose release (Bragg Peak - BP), during the treatment. To ensure correct 'in-treatment' dose deposition, range monitoring techniques, currently missing in light ion treatment techniques, are eagerly needed. The results presented in this manuscript indicate that charged secondary particles, mainly protons, produced by an 16O beam during target irradiation can be considered as candidates for 16O beam range monitoring. Hereafter, we report on the first yield measurements of protons, deuterons and tritons produced in the interaction of an 16O beam impinging on a PMMA target, as a function of detected energy and particle production position. Charged particles were detected at 90° and 60° with respect to incoming beam direction, and homogeneous and heterogeneous PMMA targets were used to probe the sensitivity of the technique to target inhomogeneities. The reported secondary particle yields provide essential information needed to assess the accuracy and resolution achievable in clinical conditions by range monitoring techniques based on secondary charged radiation.
Collapse
|
21
|
Review and performance of the Dose Profiler, a particle therapy treatments online monitor. Phys Med 2019; 65:84-93. [PMID: 31437603 DOI: 10.1016/j.ejmp.2019.07.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 06/24/2019] [Accepted: 07/14/2019] [Indexed: 11/27/2022] Open
Abstract
Particle therapy (PT) can exploit heavy ions (such as He, C or O) to enhance the treatment efficacy, profiting from the increased Relative Biological Effectiveness and Oxygen Enhancement Ratio of these projectiles with respect to proton beams. To maximise the gain in tumor control probability a precise online monitoring of the dose release is needed, avoiding unnecessary large safety margins surroundings the tumor volume accounting for possible patient mispositioning or morphological changes with respect to the initial CT scan. The Dose Profiler (DP) detector, presented in this manuscript, is a scintillating fibres tracker of charged secondary particles (mainly protons) that will be operating during the treatment, allowing for an online range monitoring. Such monitoring technique is particularly promising in the context of heavy ions PT, in which the precision achievable by other techniques based on secondary photons detection is limited by the environmental background during the beam delivery. Developed and built at the SBAI department of "La Sapienza", within the INSIDE collaboration and as part of a Centro Fermi flagship project, the DP is a tracker detector specifically designed and planned for clinical applications inside a PT treatment room. The DP operation in clinical like conditions has been tested with the proton and carbon ions beams of Trento proton-therapy center and of the CNAO facility. In this contribution the detector performances are presented, in the context of the carbon ions monitoring clinical trial that is about to start at the CNAO centre.
Collapse
|
22
|
EP-1884 Commissioning and clinical validation of FRED: Monte Carlo on GPU for proton beam therapy. Radiother Oncol 2019. [DOI: 10.1016/s0167-8140(19)32304-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
23
|
Regularised patient-specific stopping power calibration for proton therapy planning based on proton radiographic images. Phys Med Biol 2019; 64:065008. [PMID: 30708365 DOI: 10.1088/1361-6560/ab03db] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Proton transmission imaging has been proposed and investigated as imaging modality complementary to x-ray based techniques in proton beam therapy. In particular, it addresses the issue of range uncertainties due to the conversion of an x-ray patient computed tomography (CT) image expressed in Hounsfield Units (HU) to relative stopping power (RSP) needed as input to the treatment planning system. One approach to exploit a single proton radiographic projection is to perform a patient-specific calibration of the CT to RSP conversion curve by optimising the match between a measured and a numerically integrated proton radiography. In this work, we develop the mathematical tools needed to perform such an optimisation in an efficient and robust way. Our main focus lies on set-ups which combine pencil beam scanning with a range telescope detector, although most of our methods can be employed in combination with other set-ups as well. Proton radiographies are simulated in Monte Carlo using an idealised detector and applying the same data processing chain used with experimental data. This approach allows us to have a ground truth CT-RSP curve to compare the optimisation results with. Our results show that the parameters of the CT-RSP curve are strongly correlated when using a pencil beam based set-up, which leads to unrealistic variation in the optimised CT-RSP curves. To address this issue, we introduce a regularisation procedure which guarantees a plausible degree of smoothness in the optimised CT-RSP curves. We investigate three different methods to perform the numerical projection operation needed to generate a proton digitally reconstructed radiography. We find that the approximate and computationally faster method performs as well as the more accurate but more demanding method. We perform a Monte Carlo experiment based on a head and neck patient to evaluate the range accuracy achievable with the optimised CT-RSP curves and find an agreement with the ground truth expectation of better than [Formula: see text]. Our results further indicate that the region in the patient in which the proton radiography is acquired does not necessarily have to correspond to the treatment volume to achieve this accuracy. This is important as the imaged region could be freely chosen, e.g. in order to spare organs at risk.
Collapse
|
24
|
|
25
|
Pressure calibration of a digital microelectromechanical system microphone by comparison. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:EL297. [PMID: 30404493 DOI: 10.1121/1.5059333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 09/17/2018] [Indexed: 06/08/2023]
Abstract
In the field of noise control and monitoring, a new generation of small and low-cost microelectro-mechanical system (MEMS) microphones is nowadays widely adopted. MEMS microphones, after recognition as traceable measurement instruments, could open up promising measurements based on wireless sensor networks. Current standards do not apply specifically to digital microphones. In this work, a pressure calibration procedure by comparison is carried out for a digital MEMS microphone and a sensitivity parameter suitable for metrological purposes is proposed. Measurement procedure and results between 20 Hz and 20 kHz are presented along with uncertainty contributions.
Collapse
|
26
|
Laser-accelerated particle beams for stress testing of materials. Nat Commun 2018; 9:372. [PMID: 29371647 PMCID: PMC5785512 DOI: 10.1038/s41467-017-02675-x] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Accepted: 12/18/2017] [Indexed: 11/24/2022] Open
Abstract
Laser-driven particle acceleration, obtained by irradiation of a solid target using an ultra-intense (I > 1018 W/cm2) short-pulse (duration <1 ps) laser, is a growing field of interest, in particular for its manifold potential applications in different domains. Here, we provide experimental evidence that laser-generated particles, in particular protons, can be used for stress testing materials and are particularly suited for identifying materials to be used in harsh conditions. We show that these laser-generated protons can produce, in a very short time scale, a strong mechanical and thermal damage, that, given the short irradiation time, does not allow for recovery of the material. We confirm this by analyzing changes in the mechanical, optical, electrical, and morphological properties of five materials of interest to be used in harsh conditions. Recently, there has been significant progress on the application of laser-generated proton beams in material science. Here the authors demonstrate the benefit of employing such beams in stress testing different materials by examining their mechanical, optical, electrical, and morphological properties.
Collapse
|
27
|
A fast - Monte Carlo toolkit on GPU for treatment plan dose recalculation in proton therapy. ACTA ACUST UNITED AC 2017. [DOI: 10.1088/1742-6596/905/1/012027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
28
|
Fred: a GPU-accelerated fast-Monte Carlo code for rapid treatment plan recalculation in ion beam therapy. ACTA ACUST UNITED AC 2017; 62:7482-7504. [DOI: 10.1088/1361-6560/aa8134] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
29
|
Abstract
Multimegabar laser-driven shock waves are unique tools for studying matter under extreme conditions. Accurate characterization of shocked matter is for instance necessary for measurements of equation of state data or opacities. This paper reports experiments performed at the LULI facility on the diagnosis of shock waves, using x-ray-absorption radiography. Radiographs are analyzed using standard Abel inversion. In addition, synthetic radiographs, which also take into account the finite size of the x-ray source, are generated using density maps produced by hydrodynamic simulations. Reported data refer to both plane cylindrical targets and hemispherical targets. Evolution and deformation of the shock front could be followed using hydrodynamic simulations.
Collapse
|
30
|
741 UV stress directs Cockayne Syndrome (CS) B protein to the centrosome to control α-tubulin acetylation and autophagy. J Invest Dermatol 2017. [DOI: 10.1016/j.jid.2017.02.765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Independent tuning of acoustic and mechanical properties of phantoms for biomedical applications of ultrasound. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa5ed0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
32
|
Sites de Redes Sociais na Contemporaneidade: Percepções dos Usuários Sobre Emoções, Vivências e Relações. REVISTA DE PSICOLOGIA DA IMED 2016. [DOI: 10.18256/2175-5027/psico-imed.v8n2p133-141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
33
|
Erratum to: 36th International Symposium on Intensive Care and Emergency Medicine: Brussels, Belgium. 15-18 March 2016. Crit Care 2016; 20:347. [PMID: 31268434 PMCID: PMC5078922 DOI: 10.1186/s13054-016-1358-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Accepted: 05/13/2016] [Indexed: 11/27/2022] Open
Abstract
[This corrects the article DOI: 10.1186/s13054-016-1208-6.].
Collapse
|
34
|
565 Aberrant histone acetylation is linked to lysosomal and autophagic dysfunction in Cockayne syndrome (CS). J Invest Dermatol 2016. [DOI: 10.1016/j.jid.2016.02.604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
35
|
FRED: a fast MC tool for treatment planning and dose verification in proton therapy. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)30169-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
36
|
Strain-rate and temperature dependent material properties of Agar and Gellan Gum used in biomedical applications. J Mech Behav Biomed Mater 2016; 53:119-130. [DOI: 10.1016/j.jmbbm.2015.08.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 07/28/2015] [Accepted: 08/04/2015] [Indexed: 10/23/2022]
|
37
|
Using a family history questionnaire to identify adult patients with increased genetic risk for sarcoma. ACTA ACUST UNITED AC 2015; 22:317-25. [PMID: 26628864 DOI: 10.3747/co.22.2588] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Sarcomas in adults can be associated with hereditary cancer syndromes characterized by early-onset predisposition to numerous types of cancer. Because of variability in familial presentation and the largely unexplained genetic basis of sarcomas, ascertainment of patients for whom a genetics evaluation is most indicated poses challenges. We assessed the utility of a Sarcoma Clinic Genetic Screening (scgs) questionnaire in facilitating that task. METHODS Between 2008 and 2012, 169 patients (median age: 53 years; range: 17-88 years) completed a self-administered scgs questionnaire. A retrospective chart review was completed for all respondents, and descriptive statistics were reported. Probands were divided into two groups depending on whether they did or did not report a family history of Li-Fraumeni syndrome-type cancers. RESULTS A family history of cancer (as far as 3rd-degree relatives) was reported in 113 of 163 sarcoma patients (69%). Eeles Li-Fraumeni-like (lfl) criteria were fulfilled in 46 probands (28%), Chompret lfl in 21 (13%), Birch lfl in 8 (5%), and classic Li-Fraumeni in none. In the 10 probands tested for TP53 mutations, 1 pathogenic mutation was found. Further investigation of selected families led to the discovery of germline mutations in MLH1, MSH2, and APC genes in 3 individuals. CONCLUSIONS The scgs questionnaire was useful for ascertaining probands with sarcoma who could benefit from a genetic assessment. The tool allowed us to identify high-risk families fitting the criteria for lfl and, surprisingly, other hereditary cancer syndromes. Similar questionnaires could be used in other cancer-specific clinics to increase awareness of the genetic component of these cancers.
Collapse
|
38
|
Modified Thomson spectrometer design for high energy, multi-species ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:033304. [PMID: 24689572 DOI: 10.1063/1.4866021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A modification to the standard Thomson parabola spectrometer is discussed, which is designed to measure high energy (tens of MeV/nucleon), broad bandwidth spectra of multi-species ions accelerated by intense laser plasma interactions. It is proposed to implement a pair of extended, trapezoidal shaped electric plates, which will not only resolve ion traces at high energies, but will also retain the lower energy part of the spectrum. While a longer (along the axis of the undeflected ion beam direction) electric plate design provides effective charge state separation at the high energy end of the spectrum, the proposed new trapezoidal shape will enable the low energy ions to reach the detector, which would have been clipped or blocked by simply extending the rectangular plates to enhance the electrostatic deflection.
Collapse
|
39
|
17: MCTP: a new Monte Carlo-based treatment planning tool for hadrontherapy. Radiother Oncol 2014. [DOI: 10.1016/s0167-8140(15)34038-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
40
|
|
41
|
A survey of methods for the evaluation of tissue engineering scaffold permeability. Ann Biomed Eng 2013; 41:2027-41. [PMID: 23612914 DOI: 10.1007/s10439-013-0815-5] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Accepted: 04/17/2013] [Indexed: 12/24/2022]
Abstract
The performance of porous scaffolds for tissue engineering (TE) applications is evaluated, in general, in terms of porosity, pore size and distribution, and pore tortuosity. These descriptors are often confounding when they are applied to characterize transport phenomena within porous scaffolds. On the contrary, permeability is a more effective parameter in (1) estimating mass and species transport through the scaffold and (2) describing its topological features, thus allowing a better evaluation of the overall scaffold performance. However, the evaluation of TE scaffold permeability suffers of a lack of uniformity and standards in measurement and testing procedures which makes the comparison of results obtained in different laboratories unfeasible. In this review paper we summarize the most important features influencing TE scaffold permeability, linking them to the theoretical background. An overview of methods applied for TE scaffold permeability evaluation is given, presenting experimental test benches and computational methods applied (1) to integrate experimental measurements and (2) to support the TE scaffold design process. Both experimental and computational limitations in the permeability evaluation process are also discussed.
Collapse
|
42
|
|
43
|
|
44
|
Preliminary results from recent experiments and future roadmap to Shock Ignition of Fusion Targets. ACTA ACUST UNITED AC 2012. [DOI: 10.1088/1742-6596/399/1/012005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
45
|
300 A RESEARCH TOOL FOR MONTE CARLO-BASED TREATMENT PLANNING WITH PROTONS AND IONS. Radiother Oncol 2012. [DOI: 10.1016/s0167-8140(12)70262-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
46
|
Vectorial phase retrieval for linear characterization of attosecond pulses. PHYSICAL REVIEW LETTERS 2011; 107:133902. [PMID: 22026855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Indexed: 05/31/2023]
Abstract
The waveforms of attosecond pulses produced by high-harmonic generation carry information on the electronic structure and dynamics in atomic and molecular systems. Current methods for the temporal characterization of such pulses have limited sensitivity and impose significant experimental complexity. We propose a new linear and all-optical method inspired by widely used multidimensional phase retrieval algorithms. Our new scheme is based on the spectral measurement of two attosecond sources and their interference. As an example, we focus on the case of spectral polarization measurements of attosecond pulses, relying on their most fundamental property-being well confined in time. We demonstrate this method numerically by reconstructing the temporal profiles of attosecond pulses generated from aligned CO(2) molecules.
Collapse
|
47
|
Enhanced propagation for relativistic laser pulses in inhomogeneous plasmas using hollow channels. PHYSICAL REVIEW LETTERS 2010; 105:225001. [PMID: 21231391 DOI: 10.1103/physrevlett.105.225001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2009] [Indexed: 05/30/2023]
Abstract
The influence of long (several millimeters) and hollow channels, bored in inhomogeneous ionized plasma by using a long pulse laser beam, on the propagation of short, ultraintense laser pulses has been studied. Compared to the case without a channel, propagation in channels significantly improves beam transmission and maintains a beam quality close to propagation in vacuum. In addition, the growth of the forward-Raman instability is strongly reduced. These results are beneficial for the direct scheme of the fast ignitor concept of inertial confinement fusion as we demonstrate, in fast-ignition-relevant conditions, that with such channels laser energy can be carried through increasingly dense plasmas close to the fuel core with minimal losses.
Collapse
|
48
|
Scaling in temporal occurrence of quasi-rigid-body vibration pulses due to macrofractures. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2010; 82:046115. [PMID: 21230353 DOI: 10.1103/physreve.82.046115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Revised: 09/24/2010] [Indexed: 05/30/2023]
Abstract
We subjected the time series of quasi-rigid-body vibration pulses (elastic emissions) from laboratory fracture carried out by a piezoelectric accelerometer on concrete and rock specimens under uniaxial compression to statistical analysis. In both cases, we find that the waiting-time distribution can be described by a scaling law extending over several orders of magnitude. This law is indistinguishable from a universal scaling law recently proposed for the waiting-time distributions of acoustic emissions in heterogeneous materials and earthquakes, suggesting its general validity for fracture processes independent of modes and magnitude scales.
Collapse
|
49
|
Proton radiography of a shock-compressed target. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2010; 82:016407. [PMID: 20866747 DOI: 10.1103/physreve.82.016407] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2010] [Indexed: 05/29/2023]
Abstract
In this paper we report on the radiography of a shock-compressed target using laser produced proton beams. A low-density carbon foam target was shock compressed by long pulse high-energy laser beams. The shock front was transversally probed with a proton beam produced in the interaction of a high intensity laser beam with a gold foil. We show that from radiography data, the density profile in the shocked target can be deduced using Monte Carlo simulations. By changing the delay between long and short pulse beams, we could probe different plasma conditions and structures, demonstrating that the details of the steep density gradient can be resolved. This technique is validated as a diagnostic for the investigation of warm dense plasmas, allowing an in situ characterization of high-density contrasted plasmas.
Collapse
|
50
|
Plasma jets driven by ultraintense-laser interaction with thin foils. PHYSICAL REVIEW LETTERS 2008; 100:225004. [PMID: 18643426 DOI: 10.1103/physrevlett.100.225004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2007] [Indexed: 05/26/2023]
Abstract
Experimental evidence of plasma jets ejected from the rear side of thin solid targets irradiated by ultraintense (>10(19) W cm(-2)) laser pulses is presented. The jets, detected by transverse interferometric measurements with high spatial and temporal resolutions, show collimated expansion lasting for several hundreds of picoseconds and have substantially steep density gradients at their periphery. The role played by radiation pressure of the laser in the jet formation process is highlighted analytically and by extensive two-dimensional particle-in-cell simulations.
Collapse
|