Measuring Visual Fields in Children With Glaucoma Using a Portable Tablet. Transl Vis Sci Technol 2024; 13:10. [PMID: 38743410 PMCID: PMC11103736 DOI: 10.1167/tvst.13.5.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 03/19/2024] [Indexed: 05/16/2024] Open
Abstract
Purpose To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.
Collapse
|
2
|
Retinal Vascular Measurements and Mortality Risk: Evidence From the UK Biobank Study. Transl Vis Sci Technol 2024; 13:2. [PMID: 38165718 PMCID: PMC10773151 DOI: 10.1167/tvst.13.1.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 11/03/2023] [Indexed: 01/04/2024] Open
Abstract
Purpose This study aimed to investigate the association between quantitative retinal vascular measurements and the risk of all-cause and premature mortality. Methods In this population-based cohort study using the UK Biobank data, we employed the Retina-based Microvascular Health Assessment System to assess fundus images for image quality and extracted 392 retinal vascular measurements per fundus image. These measurements encompass six categories of vascular features: caliber, density, length, tortuosity, branching angle, and complexity. Univariate Cox regression models were used to identify potential indicators of mortality risk using data on all-cause and premature mortality from death registries. Multivariate Cox regression models were then used to test these associations while controlling for confounding factors. Results The final analysis included 66,415 participants. After adjusting for demographic, health, and lifestyle factors and genetic risk score, 18 and 10 retinal vascular measurements were significantly associated with all-cause mortality and premature mortality, respectively. In the fully adjusted model, the following measurements of different vascular features were significantly associated with all-cause mortality and premature mortality: arterial bifurcation density (branching angle), number of arterial segments (complexity), interquartile range and median absolute deviation of arterial curve angle (tortuosity), mean and median values of mean pixel widths of all arterial segments in each image (caliber), skeleton density of arteries in macular area (density), and minimum venular arc length (length). Conclusions The study revealed 18 retinal vascular measurements significantly associated with all-cause mortality and 10 associated with premature mortality. Those identified parameters should be further studied for biological mechanisms connecting them to increased mortality risk. Translational Relevance This study identifies retinal biomarkers for increased mortality risk and provides novel targets for investigating the underlying biological mechanisms.
Collapse
|
3
|
Vision and Visuomotor Performance Following Acute Ischemic Stroke. Front Neurol 2022; 13:757431. [PMID: 35250804 PMCID: PMC8889933 DOI: 10.3389/fneur.2022.757431] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 01/17/2022] [Indexed: 11/18/2022] Open
Abstract
Background As measurable sensory and motor deficits are key to the diagnosis of stroke, we investigated the value of objective tablet based vision and visuomotor capacity assessment in acute mild-moderate ischemic stroke (AIS) patients. Methods Sixty AIS patients (65 ± 14 years, 33 males) without pre-existing visual/neurological disorders and acuity better than 6/12 were tested at their bedside during the first week post-stroke and were compared to 40 controls (64 ± 11 years, 15 males). Visual field sensitivity, quantified as mean deviation (dB) and visual acuity (with and without luminance noise), were tested on MRFn (Melbourne Rapid Field-Neural) iPad application. Visuomotor capacity was assessed with the Lee-Ryan Eye-Hand Coordination (EHC) iPad application using a capacitive stylus for iPad held in the preferred hand.Time to trace 3 shapes and displacement errors (deviations of >3.5 mm from the shape) were recorded. Diagnostic capacity was considered with Receiver Operating Characteristics. Vision test outcomes were correlated with National Institutes of Health Stroke Scale (NIHSS) score at the admission. Results Of the 60 AIS patients, 58 grasped the iPad stylus in their preferred right hand even though 31 had left hemisphere lesions. Forty-one patients (68%) with better than 6/12 visual acuity (19 right, 19 left hemisphere and 3 multi-territorial lesions) returned significantly abnormal visual fields. The stroke group took significantly longer (AIS: 93.4 ± 60.1 s; Controls: 33.1 ± 11.5 s, p < 0.01) to complete EHC tracing and made larger displacements (AIS: 16,388 ± 36,367 mm; Controls: 2,620 ± 1,359 mm, p < 0.01) although both control and stroke groups made similar numbers of errors. EHC time was not significantly different between participants with R (n = 26, 84.3 ± 55.3 s) and L (n = 31, 101.3 ± 64.7 s) hemisphere lesions. NIHSS scores and EHC measures showed low correlations (Spearman R: −0.15, L: 0.17). ROC analysis of EHC and vision tests found high diagnostic specificity and sensitivity for a fail at EHC time, or visual field, or Acuity-in-noise (sensivity: 93%, specificity: 83%) that shows little relationship to NIHSS scores. Conclusions EHC time and vision test outcomes provide an easy and rapid bedside measure that complements existing clinical assessments in AIS. The low correlation between visual function, NIHSS scores and lesion site offers an expanded clinical view of changes following stroke.
Collapse
|
4
|
The Short-Term Compliance and Concordance to in Clinic Testing for Tablet-Based Home Monitoring in Age-Related Macular Degeneration. Am J Ophthalmol 2022; 235:280-290. [PMID: 34509437 DOI: 10.1016/j.ajo.2021.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/02/2021] [Accepted: 09/02/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE The aim of this study was to determine the short-term compliance with regular home monitoring of macular retinal sensitivity (RS) in intermediate age-related macular degeneration (iAMD). Home-based outcomes were compared with in-clinic outcomes determined using (1) the same tablet device under supervision, and (2) the Macular Integrity Assessment (MaIA) microperimeter. DESIGN Single-center longitudinal compliance and reliability study. METHODS A total of 73 participants with iAMD were trained to perform macular field testing with the Melbourne Rapid Fields-macular (MRF-m) iPad application. Volunteers were asked to return 6 weekly tests from home, guided by audio instructions. We determined compliance with weekly testing and surveyed for factors that limited compliance. Test reliability (false positive, false negative) and RS were compared to in-clinic assays (MaIA). Data are given as mean ± SD or as median [quartile 1-3 range]. Group comparisons were achieved with bootstrap to define the 95% confidence limits. RESULTS A total of 59 participants submitted 6 home examinations with a median intertest interval of 8.0 [7.0-17] days. Compliance with weekly testing (7 days ±24 hours) was 55%. The main barrier to compliance was information technology (IT) logistic reasons. Of 694 home examinations submitted, 96% were reliable (false-positive results <25%). The mean RS returned by the tablet was significantly higher (+3.2 dB, P < .05) compared to the MaIA. CONCLUSIONS Home monitoring produces reliable results that differ from in-clinic tests because of test design. This should not affect self-monitoring once an at-home baseline is established, but these differences will affect comparisons with in-clinic outcomes. Reasonable compliance with weekly testing was achieved. Improved IT support might lead to better compliance.
Collapse
|
5
|
Scaling the size of perimetric stimuli reduces variability and returns constant thresholds across the visual field. J Vis 2021; 21:2. [PMID: 34617957 PMCID: PMC8504188 DOI: 10.1167/jov.21.11.2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The conventional stimulus for standard automated perimetry is fixed in size, giving elevated contrast thresholds and reduced test reliability in the periphery. Here, we test the hypothesis that appropriate scaling of the size of perimetric stimuli will return fixed thresholds and reduced variability across the visual field. We derived frequency-of-seeing (FOS) curves in five healthy subjects at central (3 degrees) and peripheral (27 degrees) locations with a method of constant stimuli (MOCS) using a desktop LCD display. FOS curves for a Goldmann III (GIII) stimulus were compared with those for size scaled spots. To consider clinical translation, we tested a further five healthy subjects (22–24 years) with the Melbourne Rapid Fields (MRF) tablet perimeter at several locations spanning 1 degree to 25 degrees from fixation, deriving FOS curves (MOCS) and also conducting repeated adaptive clinical thresholding to assess intra- and interobserver variability. We found that GIII contrast thresholds were significantly elevated in the periphery compared with the parafovea, with concomitant reduction of FOS slope. Using appropriately size scaled spots, threshold and slope differences between these locations were significantly reduced. FOS data collected with the tablet perimeter confirmed that size scaling confers broad equivalence of the shape of the FOS curve across the visual field. Repeated adaptive thresholding with size scaled stimuli gave relatively constant intra-observer variability across the visual field, which compares favorably with published normative data obtained with the GIII stimulus. The reduced variability will improve signal-to-noise ratio for correct classification of normal visual field test results, whereas the lower contrast thresholds yield greater dynamic range, which should improve the ability to reliably monitor moderate defects.
Collapse
|
6
|
Screening for Glaucomatous Visual Field Defects in Rural Australia with an iPad. J Curr Glaucoma Pract 2021; 15:125-131. [PMID: 35173394 PMCID: PMC8807937 DOI: 10.5005/jp-journals-10078-1312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Aim and objective Developing improved methods for early detection of visual field defects is pivotal to reducing glaucoma-related vision loss. The Melbourne Rapid Fields screening module (MRF-S) is an iPad-based test, which allows suprathreshold screening with zone-based analysis to rapidly assess the risk of manifest glaucoma. The versatility of MRF-S has potential utility in rural areas and during infectious pandemics. This study evaluates the utility of MRF-S for detecting field defects in non-metropolitan settings. Materials and methods This was a prospective, multicenter, cross-sectional validation study. Two hundred and fifty-two eyes of 142 participants were recruited from rural sites through two outreach eye services in Australia. Participants were tested using MRF-S and compared with a reference standard; either Zeiss Humphrey Field Analyzer or Haag-Streit Octopus performed at the same visit. Standardized questionnaires were used to assess user acceptability. Major outcome measures were the area under the curve (AUC) for detecting mild and moderate field defects defined by the reference tests, along with corresponding performance characteristics (sensitivity, specificity). Results The mean test duration for MRF-S was 1.88 minutes compared with 5.92 minutes for reference tests. The AUCs for mild and moderate field defects were 0.81 [95% confidence interval (CI): 0.75–0.87] and 0.87 (95% CI: 0.83–0.92), respectively, indicating very good diagnostic accuracy. Using a risk criterion of 55%, MRF-S identified moderate field defects with a sensitivity and specificity of 88.4 and 81.0%, respectively. Conclusion and clinical significance The MRF-S iPad module can identify patients with mild and moderate field defects while delivering favorable user acceptability and short test duration. This has potential application within rural locations and amidst infectious pandemics. How to cite this article Chia MA, Trang E, Agar A, et al. Screening for Glaucomatous Visual Field Defects in Rural Australia with an iPad. J Curr Glaucoma Pract 2021;15(3):125–131.
Collapse
|
7
|
|
8
|
|
9
|
|
10
|
|
11
|
|
12
|
|
13
|
|
14
|
|
15
|
|
16
|
|
17
|
|
18
|
|
19
|
Uptake, Persistence, and Performance of Weekly Home Monitoring of Visual Field in a Large Cohort of Patients With Glaucoma. Am J Ophthalmol 2021; 223:286-295. [PMID: 33221287 DOI: 10.1016/j.ajo.2020.10.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 10/27/2020] [Accepted: 10/30/2020] [Indexed: 01/29/2023]
Abstract
PURPOSE This study examines the short-term uptake, compliance, and performance of a tablet device used for home monitoring of visual field (VF-Home) by glaucoma patients. DESIGN Single-center, observational, longitudinal, compliance study. METHODS Participants who were glaucoma suspects or had stable glaucoma in at least one eye were recruited during a regular clinic review. Baseline in-clinic visual field (VF) was recorded with the Humphrey Field Analyser (HFA, SITA standard) and repeated at 6 months. Participants were tasked with performing 6 VF examinations from home, at weekly intervals, using a loaned iPad tablet. Uptake was defined as returning at least 1 test from home. Reliability and global indices from VF-Home were compared to in-clinic outcomes. Data are shown as either mean ± [standard deviation] or median [quartile 1-3 range], and group comparisons were achieved with bootstrap. RESULTS We recruited 186 eyes of 101 participants. VF-Home uptake was excellent, with 88% of participants successfully completing ≥1 home examination and 69% completing all 6 examinations. The median duration between tests was 7.0 [7.0-8.0] days. Barriers to uptake and compliance involved information technology (IT) logistical reasons, lack of motivation, or competing life demands. VF-Home gave greater fixation loss but a similar level of False Positives (FP) as the HFA. A high correlation was found for the mean defect between in-clinic and at-home outcomes (R = 0.85). CONCLUSIONS VF-Home can return a high level of short-term compliance and results comparable to those found by in-clinic testing. IT logistical reasons and lack of motivation are barriers to uptake and compliance.
Collapse
|
20
|
Retinal Functional and Structural Changes in the 5xFAD Mouse Model of Alzheimer's Disease. Front Neurosci 2020; 14:862. [PMID: 32903645 PMCID: PMC7438734 DOI: 10.3389/fnins.2020.00862] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/24/2020] [Indexed: 12/18/2022] Open
Abstract
Alzheimer’s disease is characterized by the aberrant deposition of protein in the brain and is the leading cause of dementia worldwide. Increasingly, there have been reports of the presence of these protein hallmarks in the retina. In this study, we assayed the retina of 5xFAD mice, a transgenic model of amyloid deposition known to exhibit dementia-like symptoms with age. Using OCT, we found that the retinal nerve fiber layer was thinner in 5xFAD at 6, 12, and 17 months of age compared with wild-type littermates, but the inner plexiform layer was thicker at 6 months old. Retinal function showed reduced ganglion cell responses to light in 5xFAD at 6, 12, and 17 months of age. This functional loss was observed in the outer retina at 17 months of age but not in younger mice. We showed using immunohistochemistry and ELISA that soluble and insoluble amyloid was present in the retina and brain at all ages. In conclusion, we report that amyloid is present in brain and retina of 5xFAD mice and that the pattern of neuronal dysfunction occurs in the inner retina at the early ages and progresses to encompass the outer retina with age. This implies that the inner retina is more sensitive to amyloid changes in early disease and that the outer retina is also affected with disease progression.
Collapse
|
21
|
Acquired Visual Deficits Independent of Lesion Site in Acute Stroke. Front Neurol 2020; 11:705. [PMID: 32765410 PMCID: PMC7380328 DOI: 10.3389/fneur.2020.00705] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/10/2020] [Indexed: 11/24/2022] Open
Abstract
Most clinical diagnoses of stroke are based on the persistence of symptoms relating to consciousness, language, visual-field loss, extraocular movement, neglect (visual), motor strength, and sensory loss following acute cerebral infarction. Yet despite the fact that most motor actions and cognition are driven by vision, functional vision per se is seldom tested rigorously during hospitalization. Hence we set out to determine the effects of acute stroke on functional vision, using an iPad application (Melbourne Rapid Field-Neural) that can be used to assess vision (visual acuity and visual field sensitivity) at the bedside or in the emergency ward in about 6 min per eye. Our convenience sample comprised 60 (29–88 years, 65 ± 14 years, 33 males) of 160 sequentially presenting first episode, acute (<7 days) ischemic stroke patients at Sunshine Hospital, Melbourne. One hundred patients were excluded due to existing eye disease, inadequate radiological confirmation, inability to comply with English directions or too ill to participate. Stroke cases were compared with 37 (29–85 years, 64 ± 12 years,14 males) similar-aged controls using a Mann-Whitney U-test. A significant loss in visual field sensitivity was measured in 68% of stroke cases (41/60, Mean Deviation: Stroke: −5.39 ± 6.26 dB, Control: 0.30 ± 0.60 dB, MWU = 246, p < 0.0001). Surprisingly, 44% (18/41) of these patients were unaware of their field loss. Although high contrast visual acuity was unaffected in most (55/60) patients, visual acuity-in-noise was reduced in 62% (37/60, Stroke: mean 6/12−2, log MAR 0.34 ± 0.21 vs. Control: mean 6/7·5–2, log MAR 0.14 ± 0.10; MWU = 470, p < 0.0001). Visual field defects were associated with all occipital, parietal and posterior cerebellar artery strokes while 9/15 middle cerebral artery lesions and 11 lesions in other brain regions were also associated with visual field defects. Our findings demonstrate that ~2/3 of acute first episode ischemic stroke patients experience acquired vision deficits, often unrelated to the confirmed lesion site. Our results also imply that visual dysfunction may be associated with a more generalized cerebral dysfunction while highlighting the need for bedside testing of vision for every stroke patient and demonstrating the translational clinical value of the “Melbourne Rapid Field- Neural” iPad application. Clinical Trial:http://www.ANZCTR.org.au/ACTRN12618001111268.aspx.
Collapse
|
22
|
Reversibility of Retinal Ganglion Cell Dysfunction From Chronic IOP Elevation. Invest Ophthalmol Vis Sci 2020; 60:3878-3886. [PMID: 31529082 DOI: 10.1167/iovs.19-27113] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To test the hypothesis that the capacity for retinal ganglion cells to functionally recover from chronic IOP elevation is dependent on the duration of IOP elevation. Methods IOP elevation was induced in one eye in anesthetized (isoflurane) adult C57BL6/J mice using a circumlimbal suture. Sutures were left in place for 8 and 16 weeks (n = 30 and 28). In two other groups the suture was cut after 8 and 12 weeks (n = 30 and 28), and ganglion cell function (electroretinography) and retinal structure (optical coherence tomography) were assessed 4 weeks later. Ganglion cell density was quantified by counting RBPMS (RNA-binding protein with multiple splicing)-stained cells. Results With IOP elevation (∼10 mm Hg above baseline), ganglion cell function declined to 75% ± 8% at 8 weeks and 59% ± 4% at 16 weeks relative to contralateral control eyes. The retinal nerve fiber layer was thinner at 8 (84% ± 4%) and 16 weeks (83% ± 3%), without a significant difference in total retinal thickness. Ganglion cell function recovered with IOP normalization (suture removal) at week 8 (97% ± 7%), but not at week 12 (73% ± 6%). Ganglion cell loss was found in all groups (-8% to -13%). Conclusions In the mouse circumlimbal suture model, 12 weeks of IOP elevation resulted in irreversible ganglion cell dysfunction, whereas retinal dysfunction was fully reversible after 8 weeks of IOP elevation.
Collapse
|
23
|
Modulating Contact Lens Discomfort With Anti-Inflammatory Approaches: A Randomized Controlled Trial. Invest Ophthalmol Vis Sci 2019; 59:3755-3766. [PMID: 30046817 DOI: 10.1167/iovs.18-24758] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To assess the efficacy of anti-inflammatory approaches, comprising a topical corticosteroid and omega-3 supplements, for modulating the inflammatory overlay associated with contact lens discomfort (CLD). Methods This randomized controlled trial involved 72 adults with CLD, randomized (1:1:1:1) to one of the following: placebo (oral olive oil), oral fish oil (900 mg/d eicosapentaenoic acid [EPA] + 600 mg/d docosohexaenoic acid [DHA]), oral combined fish+flaxseed oils (900 mg/d EPA + 600 mg/d DHA + 900 mg/d alpha-linolenic acid), or omega-3 eye-drops (0.025% EPA + 0.0025% DHA four times per day [qid]) for 12 weeks, with visits at baseline, weeks 4 and 12. At week 12, participants who received placebo were assigned a low-potency corticosteroid (fluorometholone [FML] 0.1%, drops, three times per day [tid]) for 2 weeks (week 14). Results Sixty-five participants completed the primary endpoint. At week 12, contact lens dry-eye questionnaire (CLDEQ-8) score was reduced from baseline with oral fish oil (-7.3 ± 0.8 units, n = 17, P < 0.05), compared with placebo (-3.5 ± 0.9 units, n = 16). FML produced significant reductions in tear IL-17A (-71.1 ± 14.3%, n = 12) and IL-6 (-47.6 ± 17.5%, n = 12, P < 0.05) relative to its baseline (week 12). At week 12, tear IL-17A levels were reduced from baseline in the oral fish oil (-63.2 ± 12.8%, n = 12, P < 0.05) and topical omega-3 (-76.2 ± 10.8%, n = 10, P < 0.05) groups, compared with placebo (-3.8 ± 12.7%, n = 12). Tear IL-6 was reduced with all omega-3 interventions, relative to placebo (P < 0.05) at week 12. Conclusions CLD was attenuated by oral long-chain omega-3 supplementation for 12 weeks. Acute (2 week) topical corticosteroids and longer-term (12 week) omega-3 supplementation reduced tear levels of the proinflammatory cytokines IL-17A and IL-6, demonstrating parallels in modulating ocular inflammation with these approaches.
Collapse
|
24
|
Clinical Outcomes of Fixed Versus As-Needed Use of Artificial Tears in Dry Eye Disease: A 6-Week, Observer-Masked Phase 4 Clinical Trial. Invest Ophthalmol Vis Sci 2019; 59:2275-2280. [PMID: 29715369 DOI: 10.1167/iovs.17-23733] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To evaluate the clinical effects of using fixed (four times daily [QID]) versus as-needed (PRN) dosing of an artificial tear product (polyethylene glycol/propylene glycol [PEG/PG]; Systane Ultra) in individuals with dry eye disease. Methods In this prospective, multicenter, observer-masked, active-control, parallel-group trial, participants were randomized (1:2 allocation) to receive 1 drop of PEG/PG QID (n = 34) or PRN (n = 63) for 28 days. The primary endpoint was change from baseline in the total ocular surface staining (TOSS) score (according to the Oxford scale) at day 28. Results At day 28, the change from baseline in least squares mean (LSM) TOSS scores for QID and PRN groups were -1.19 and -0.94, respectively (treatment difference [TD]: -0.26; 95% confidence interval [CI]: -∞ to 0.21; P = 0.184); superiority of QID versus PRN dosing was not established, as the upper limit of one-sided 95% CI for TD was not <0 (prespecified limit). At day 28, for QID and PRN groups, the LSM change from baseline in Impact of Dry Eye on Everyday Life (IDEEL) scores was symptom-bother, -7.0 and -2.94 (TD: -4.06, P = 0.037); treatment effectiveness, 2.43 and 0.16 (TD: 2.28, P = 0.278); and treatment-related inconvenience, -11.56 and -2.77 (TD: -8.8, P = 0.996), respectively. Incidence of adverse events was low (≤3.2%) in both the groups; no serious adverse events were reported. Conclusions QID dosing of PEG/PG was not superior to PRN dosing in terms of ocular staining. The IDEEL symptom-bother score favored QID dosing, suggesting that regular use of artificial tears may provide better symptomatic relief than PRN use. (ClinicalTrials.gov number, NCT02446015.).
Collapse
|
25
|
An Electrophysiological Comparison of Contrast Response Functions in Younger and Older Adults, and Those With Glaucoma. Invest Ophthalmol Vis Sci 2019; 60:442-450. [PMID: 30703209 DOI: 10.1167/iovs.17-23522] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Aging and glaucoma both result in contrast processing deficits. However, it is unclear the extent to which these functional deficits arise from retinal or post-retinal neuronal changes. This study aims to disentangle the effects of healthy human aging and glaucoma on retinal and post-retinal contrast processing using visual electrophysiology. Methods Steady-state pattern electroretinograms (PERG) and pattern visual evoked potentials (PVEP) were simultaneously recorded across a range of contrasts (0%, 4%, 9%, 18%, 39%, 73%, 97%; 0.8° diameter checks, 31° diameter checkerboard) in 13 glaucoma patients (67 ± 6 years), 15 older (63 ± 8 years) and 14 younger adults (27 ± 3 years). PERG and PVEP contrast response functions were fit with a linear and saturating hyperbolic model, respectively. PERG and PVEP magnitude, timing (phase), and model fit parameters (slope, semi-saturation constant) were compared between groups. Results PERG responses were reduced and delayed in older adults relative to younger adults, and further reduced and delayed in glaucoma patients across all contrasts. PVEP signals were also reduced and delayed in glaucoma patients, relative to age-similar (older) controls. However, despite having reduced PERG magnitudes, older adults did not demonstrate reduced PVEP magnitudes. Conclusions Older adults with healthy vision demonstrate reduced magnitude and delayed timing in the PERG that is not reflected in the PVEP. In contrast, glaucoma produces functional deficits in both PERG and PVEP contrast response functions. Our results suggest that glaucomatous effects on contrast processing are not a simple extension of those that arise as part of the aging process.
Collapse
|
26
|
Abstract
The circumlimbal suture is a technique for inducing experimental glaucoma in rodents by chronically elevating intraocular pressure (IOP), a well-known risk factor for glaucoma. This protocol demonstrates a step-by-step guide on this technique in Long Evans rats and C57BL/6 mice. Under general anesthesia, a "purse-string" suture is applied on the conjunctiva, around the equator and behind the limbus of the eye. The fellow eye serves as an untreated control. Over the duration of our study, which was a period of 8 weeks for rats and 12 weeks for mice, IOP remained elevated, as measured regularly by rebound tonometry in conscious animals without topical anesthesia. In both species, the sutured eyes showed electroretinogram features consistent with preferential inner retinal dysfunction. Optical coherence tomography showed selective thinning of the retinal nerve fiber layer. Histology of the rat retina in cross-section found reduced cell density in the ganglion cell layer, but no change in other cellular layers. Staining of flat-mounted mouse retinae with a ganglion cell specific marker (RBPMS) confirmed ganglion cell loss. The circumlimbal suture is a simple, minimally invasive and cost-effective way to induce ocular hypertension that leads to ganglion cell injury in both rats and mice.
Collapse
|
27
|
Six-month Longitudinal Comparison of a Portable Tablet Perimeter With the Humphrey Field Analyzer. Am J Ophthalmol 2018; 190:9-16. [PMID: 29550190 DOI: 10.1016/j.ajo.2018.03.009] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 03/04/2018] [Accepted: 03/07/2018] [Indexed: 10/17/2022]
Abstract
PURPOSE To establish the medium-term repeatability of the iPad perimetry app Melbourne Rapid Fields (MRF) compared to Humphrey Field Analyzer (HFA) 24-2 SITA-standard and SITA-fast programs. DESIGN Multicenter longitudinal observational clinical study. METHODS Sixty patients (stable glaucoma/ocular hypertension/glaucoma suspects) were recruited into a 6-month longitudinal clinical study with visits planned at baseline and at 2, 4, and 6 months. At each visit patients undertook visual field assessment using the MRF perimetry application and either HFA SITA-fast (n = 21) or SITA-standard (n = 39). The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests. Secondary measures were the point-wise threshold and repeatability for each test, as well as test time. RESULTS MRF was similar to SITA-fast in speed and significantly faster than SITA-standard (MRF 4.6 ± 0.1 minutes vs SITA-fast 4.3 ± 0.2 minutes vs SITA-standard 6.2 ± 0.1 minutes, P < .001). Intraclass correlation coefficients (ICC) between MRF and SITA-fast for MD at the 4 visits ranged from 0.71 to 0.88. ICC values between MRF and SITA-standard for MD ranged from 0.81 to 0.90. Repeatability of MRF MD outcomes was excellent, with ICC for baseline and the 6-month visit being 0.98 (95% confidence interval: 0.96-0.99). In comparison, ICC at 6-month retest for SITA-fast was 0.95 and SITA-standard 0.93. Fewer points changed with the MRF, although for those that did, the MRF gave greater point-wise variability than did the SITA tests. CONCLUSIONS MRF correlated strongly with HFA across 4 visits over a 6-month period, and has good test-retest reliability. MRF is suitable for monitoring visual fields in settings where conventional perimetry is not readily accessible.
Collapse
|
28
|
Systemic hypertension is not protective against chronic intraocular pressure elevation in a rodent model. Sci Rep 2018; 8:7107. [PMID: 29739991 PMCID: PMC5940769 DOI: 10.1038/s41598-018-25264-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 04/16/2018] [Indexed: 02/07/2023] Open
Abstract
High intraocular pressure is the most well documented glaucoma risk factor; however many patients develop and/or show progression of glaucoma in its absence. It is now thought that in some instances, ocular perfusion pressure (blood pressure – intraocular pressure) may be as important as intraocular pressure alone. Thus, systemic hypertension would be protective against glaucoma. Epidemiological studies, however, are inconclusive. One theory of why hypertension may not protect against elevated intraocular pressure in spite of increasing ocular perfusion pressure is that with time, morphological changes to the vasculature and autoregulatory failure outweigh the benefits of improved perfusion pressure, ultimately leading to poor retinal and optic nerve head blood supply. In this study we showed the presence of increased wall:lumen ratio and wall area of the ophthalmic artery in rats with chronic hypertension in addition to failure of retinal autoregulation in response to acute modification of ocular perfusion pressure. Subsequently we found that in spite of dramatically increasing ocular perfusion pressure, chronic systemic hypertension failed to protect retinal structure and function from a rodent model of glaucoma.
Collapse
|
29
|
Age-related changes in the response of retinal structure, function and blood flow to pressure modification in rats. Sci Rep 2018; 8:2947. [PMID: 29440700 PMCID: PMC5811482 DOI: 10.1038/s41598-018-21203-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 01/29/2018] [Indexed: 12/11/2022] Open
Abstract
Age-related changes to the balance between the pressure inside the eye (intraocular pressure, IOP) and the pressure inside the brain (intracranial pressure, ICP) can modify the risk of glaucoma. In this study, we consider whether the optic nerve in older rat eyes is more susceptible to acute IOP and ICP modification. We systematically manipulate both ICP and IOP and quantify their effects on ganglion cell function (electroretinography, ERG), optic nerve structure (optical coherence tomography, OCT) and retinal blood flow (Doppler OCT). We show that ganglion cell function in older eyes was more susceptible to a higher optic nerve pressure difference (ONPD = IOP - ICP). This age-related susceptibility could not be explained by poorer blood flow with elevated ONPD. Rather, as ONPD increased the retinal nerve fibre layer showed greater compression, and the retinal surface showed less deformation in older eyes. Our data suggest that age-related changes to connective tissues in and around the rat optic nerve make it less flexible, which may result in greater strain on ganglion cell axons. This may account for greater functional susceptibility to higher optic nerve pressure differences in older rat eyes. Further studies in a species with a well-developed lamina cribrosa are needed to determine the clinical importance of these observations.
Collapse
|
30
|
Can Home Monitoring Allow Earlier Detection of Rapid Visual Field Progression in Glaucoma? Ophthalmology 2017; 124:1735-1742. [DOI: 10.1016/j.ophtha.2017.06.028] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Revised: 06/21/2017] [Accepted: 06/28/2017] [Indexed: 11/25/2022] Open
|
31
|
Abstract
Background Several visual tasks have been proposed as indirect assays of the balance between cortical inhibition and excitation in migraine. This study aimed to determine whether daily measurement of performance on such tasks can reveal perceptual changes in the build up to migraine events. Methods Visual performance was measured daily at home in 16 non-headache controls and 18 individuals with migraine using a testing protocol on a portable tablet device. Observers performed two tasks: luminance increment detection in spatial luminance noise and centre surround contrast suppression. Results Luminance thresholds were reduced in migraine compared to control groups ( p < 0.05), but thresholds did not alter across the migraine cycle; while headache-free, centre-surround contrast suppression was stronger for the migraine group relative to controls ( p < 0.05). Surround suppression weakened at around 48 hours prior to a migraine attack and strengthened to approach their headache-free levels by 24 hours post-migraine (main effect of timing, p < 0.05). Conclusions Daily portable testing of vision enabled insight into perceptual performance in the lead up to migraine events, a time point that is typically difficult to capture experimentally. Perceptual surround suppression of contrast fluctuates during the migraine cycle, supporting the utility of this measure as an indirect, non-invasive assay of the balance between cortical inhibition and excitation.
Collapse
|
32
|
Retinal and Cortical Blood Flow Dynamics Following Systemic Blood-Neural Barrier Disruption. Front Neurosci 2017; 11:568. [PMID: 29075176 PMCID: PMC5643486 DOI: 10.3389/fnins.2017.00568] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Accepted: 09/28/2017] [Indexed: 12/11/2022] Open
Abstract
To consider whether imaging retinal vasculature may be used as a marker for cortical vessels, we compared fluorescein angiography flow dynamics before and after pharmacological disruption of blood-neural barriers. Sodium fluorescein (1%, 200 μl/kg) was intravenously delivered in anesthetized adult Long Evans rats (n = 44, brain = 18, retina = 26). In the brain cohort, a cranial window was created to allow direct visualization of surface cortical vessels. Video fluorescein angiography was captured using a rodent retinal camera at 30 frames/second and fluorescence intensity profiles were evaluated for the time to reach 50% brightness (half-rise), 50% decay (half-fall), and the plateau level of remnant fluorescence (offset, %). Cortical vessels fluoresced earlier (artery half-rise: 5.6 ± 0.2 s) and decayed faster (half-fall: 10.3 ± 0.2 s) compared to retinal vasculature. Cortical vessels also had a considerably higher offset, particularly in the capillaries/extravascular space (41.4 ± 2.7%) whereas pigment in the retina reduces such residual fluorescence. In a sub-cohort of animals, sodium deoxycholate (DOC, 0.06 M dissolved in sterile saline, 1 mL) was delivered intravenously to cause simultaneous disruption of the blood-brain and blood-retinal barriers. A separate group received saline as vehicle control. Fluorescein angiography was re-measured at 6 and 24 h after drug infusion and evaluated by comparing flow dynamics to the upper quartile (75%) of the control group. Retinal vasculature was more sensitive to DOC-induced disruption with a higher fluorescence offset at 6 h (47.3 ± 10.6%). A delayed effect was seen in cortical vessels with a higher offset evident only at 24 h (65.6 ± 10.1%). Here we have developed a method to quantitatively compare fluorescein angiography dynamics in the retina and superficial cortical vessels. Our results show that systemic disruption of blood-neural barriers causes vascular leakage in both tissues but earlier in the retina suggesting that pharmacological blood-neural barrier disruption may be detected earlier in the eye than in cortical vasculature.
Collapse
|
33
|
Tablets at the bedside - iPad-based visual field test used in the diagnosis of Intrasellar Haemangiopericytoma: a case report. BMC Ophthalmol 2017; 17:53. [PMID: 28438131 PMCID: PMC5404660 DOI: 10.1186/s12886-017-0445-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 04/20/2017] [Indexed: 11/16/2022] Open
Abstract
Background In the assessment of a pituitary mass, objective visual field testing represents a valuable means of evaluating mass effect, and thus in deciding whether surgical management is warranted. Case presentation In this vignette, we describe a 73 year-old lady who presented with a three-week history of frontal headache, and ‘blurriness’ in the left side of her vision, due to a WHO grade III anaplastic haemangiopericytoma compressing the optic chiasm. We report how timely investigations, including an iPad-based visual field test (Melbourne Rapid Field, (MRF)) conducted at the bedside aided swift and appropriate management of the patient. Conclusions We envisage such a test having a role in assessing bed-bound patients in hospital where access to formal visual field testing is difficult, or indeed in rapid testing of visual fields at the bedside to screen for post-operative complications, such as haematoma.
Collapse
|
34
|
Characterization of the Circumlimbal Suture Model of Chronic IOP Elevation in Mice and Assessment of Changes in Gene Expression of Stretch Sensitive Channels. Front Neurosci 2017; 11:41. [PMID: 28239332 PMCID: PMC5301305 DOI: 10.3389/fnins.2017.00041] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Accepted: 01/19/2017] [Indexed: 12/30/2022] Open
Abstract
To consider whether a circumlimbal suture can be used to chronically elevate intraocular pressure (IOP) in mice and to assess its effect on retinal structure, function and gene expression of stretch sensitive channels. Anesthetized adult C57BL6/J mice had a circumlimbal suture (10/0) applied around the equator of one eye. In treated eyes (n = 23) the suture was left in place for 12 weeks whilst in sham control eyes the suture was removed at day two (n = 17). Contralateral eyes served as untreated controls. IOP was measured after surgery and once a week thereafter. After 12 weeks, electroretinography (ERG) was performed to assess photoreceptor, bipolar cell and retinal ganglion cell (RGC) function. Retinal structure was evaluated using optical coherence tomography. Retinae were processed for counts of ganglion cell density or for quantitative RT-PCR to quantify purinergic (P2x7, Adora3, Entpd1) or stretch sensitive channel (Panx1, Trpv4) gene expression. Immediately after suture application, IOP spiked to 33 ± 3 mmHg. After 1 day, IOP had recovered to 27 ± 3 mmHg. Between weeks 2 and 12, IOP remained elevated above baseline (control 14 ± 1 mmHg, ocular hypertensive 19 ± 1 mmHg). Suture removal at day 2 (Sham) restored IOP to baseline levels, where it remained through to week 12. ERG analysis showed that 12 weeks of IOP elevation reduced photoreceptor (−15 ± 4%), bipolar cell (−15 ± 4%) and ganglion cell responses (−19 ± 6%) compared to sham controls and respective contralateral eyes (untreated). The retinal nerve fiber layer was thinned in the presence of normal total retinal thickness. Ganglion cell density was reduced across all quadrants (superior −12 ± 5%; temporal, −7% ± 2%; inferior −9 ± 4%; nasal −8 ± 5%). Quantitative RT-PCR revealed a significant increase in Entpd1 gene expression (+11 ± 4%), whilst other genes were not significantly altered (P2x7, Adora3, Trpv4, Panx1). Our results show that circumlimbal ligation produces mild chronic ocular hypertension and retinal dysfunction in mice. Consistent with a sustained change to purinergic signaling we found an up-regulation of Entpd1.
Collapse
|
35
|
Abstract
The retina is an easily accessible out-pouching of the central nervous system (CNS) and thus lends itself to being a biomarker of the brain. More specifically, the presence of neuronal, vascular and blood-neural barrier parallels in the eye and brain coupled with fast and inexpensive methods to quantify retinal changes make ocular biomarkers an attractive option. This includes its utility as a biomarker for a number of cerebrovascular diseases as well as a drug pharmacology and safety biomarker for the CNS. It is a rapidly emerging field, with some areas well established, such as stroke risk and multiple sclerosis, whereas others are still in development (Alzheimer's, Parkinson's, psychological disease and cortical diabetic dysfunction). The current applications and future potential of retinal biomarkers, including potential ways to improve their sensitivity and specificity are discussed. This review summarises the existing literature and provides a perspective on the strength of current retinal biomarkers and their future potential.
Collapse
|
36
|
A Randomized, Double-Masked, Placebo-Controlled Clinical Trial of Two Forms of Omega-3 Supplements for Treating Dry Eye Disease. Ophthalmology 2017; 124:43-52. [DOI: 10.1016/j.ophtha.2016.09.023] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Revised: 09/19/2016] [Accepted: 09/19/2016] [Indexed: 10/20/2022] Open
|
37
|
Abstract
Alzheimer's disease (AD) is a progressive neurodegenerative disorder resulting in dementia and eventual death. It is the leading cause of dementia and the number of cases are projected to rise in the next few decades. Pathological hallmarks of AD include the presence of hyperphosphorylated tau and amyloid protein deposition. Currently, these pathological biomarkers are detected either through cerebrospinal fluid analysis, brain imaging or post-mortem. Though effective, these methods are not widely available due to issues such as the difficulty in acquiring samples, lack of infrastructure or high cost. Given that the eye possesses clear optics and shares many neural and vascular similarities to the brain, it offers a direct window to cerebral pathology. These unique characteristics lend itself to being a relatively inexpensive biomarker for AD which carries the potential for wide implementation. The development of ocular biomarkers can have far implications in the discovery of treatments which can improve the quality of lives of patients. In this review, we consider the current evidence for ocular biomarkers in AD and explore potential future avenues of research in this area.
Collapse
|
38
|
A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients. Transl Vis Sci Technol 2016; 5:2. [PMID: 27847689 PMCID: PMC5106194 DOI: 10.1167/tvst.5.6.2] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Accepted: 09/11/2016] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine the correlation between the perimetric outcomes from perimetry software Melbourne Rapid Fields (MRF) run on an Apple iPad tablet and those from the Humphrey Field Analyzer (HFA). Methods The MRF software was designed with features including variable fixation and fast thresholding using Bayes logic. Here, we report a cross-sectional study on 90 eyes from 90 participants: 12 had normal optic nerves and 78 had glaucoma with various degrees of visual field loss (41 mild and 37 moderate-severe). Exclusion criteria were patients with worse than 20/40 vision or recent intraocular surgery. The visual field outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Participants were tested twice on the MRF to establish test–retest repeatability. Results The test durations were shorter on MRF than HFA (5.7 ± 0.1 vs. 6.3 ± 0.1 minutes, P < 0.001). MRF showed a high level of concordance in its outcomes with HFA (intraclass coefficient [ICC] = 0.93 for mean defect [MD] and 0.86 for pattern deviation [PD]) although the MRF tended to give a less negative MD (1.4 dB bias) compared with the HFA. MRF also showed levels of test–retest reliability comparable to HFA (ICC = 0.93 for MD and 0.89 for PD, 95% limits of agreement −4.5 to 4.3 dB). Conclusion The perimetry results from the MRF have a strong correlation to the HFA outcomes. MRF also has test–retest reliability comparable to HFA. Translational Relevance Portable tablet perimetry may allow accurate assessment of visual field when standard perimetry machines are unavailable or unsuitable.
Collapse
|
39
|
Reversal of functional loss in a rat model of chronic intraocular pressure elevation. Ophthalmic Physiol Opt 2016; 37:71-81. [DOI: 10.1111/opo.12331] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 09/17/2016] [Indexed: 02/04/2023]
|
40
|
Abstract
Purpose: To describe a tangent perimeter developed on an Apple iPad (Melbourne Rapid Field, MRF). Methods: The MRF assays 66 locations over 28° × 18° by having the patient vary fixation. Spot size and background luminance are paired to yield constant thresholds across the field. Spot locations were selected after analysis of 360 patient records. The capacity of the MRF to detect defects was verified in five participants (age 22–28 years) by simulating four common losses: central, arcuate, quadrant, and hemianopia. We also consider the effect of: myosis, blur (+3 DS), viewing distance (25–75 cm), ambient light (4–600 lux), and retest repeatability (1-week apart) on thresholds. Group means [SEM] are compared by Student's t-test and repeatability returned from Bland-Altman analysis. Results: We found a 5 cd.m−2 background replicates the Weber fraction produced by a Humphrey spot shown at 35 dB. Our variable size gives constant thresholds (29.6 [0.2] dB) across all locations. Altering viewing distance (25 cm = 29.8 [0.9] dB; 75 cm = 28.9 [0.6] dB) and ambient lighting (4 lux, 29.8 [0.8] dB; 600 lux, 29.5 [1.0] dB) did not affect threshold although screen reflections must be avoided. Myosis (−1.2 dB) and blur (−1.5 dB) will reduce sensitivity (P < 0.05). Simulated defects with a mean defect (MD) of −3.3 dB are detected by the MRF. The Coefficient of repeatability was 9.6% (SD ∼2.9 dB) in normal regions and 48.1% (SD ∼8.0 dB) in areas of simulated scotoma. Conclusions: Tablet technology can return efficient and reliable thresholds to 30° as a tangent perimeter. Translational Relevance: The MRF will allow testing at a bedside, at home, in rural or remote areas, or where equipment cannot be financed.
Collapse
|
41
|
Simultaneous Recording of Electroretinography and Visual Evoked Potentials in Anesthetized Rats. J Vis Exp 2016. [PMID: 27404129 DOI: 10.3791/54158] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
The electroretinogram (ERG) and visual evoked potential (VEP) are commonly used to assess the integrity of the visual pathway. The ERG measures the electrical responses of the retina to light stimulation, while the VEP measures the corresponding functional integrity of the visual pathways from the retina to the primary visual cortex following the same light event. The ERG waveform can be broken down into components that reflect responses from different retinal neuronal and glial cell classes. The early components of the VEP waveform represent the integrity of the optic nerve and higher cortical centers. These recordings can be conducted in isolation or together, depending on the application. The methodology described in this paper allows simultaneous assessment of retinal and cortical visual evoked electrophysiology from both eyes and both hemispheres. This is a useful way to more comprehensively assess retinal function and the upstream effects that changes in retinal function can have on visual evoked cortical function.
Collapse
|
42
|
|
43
|
Comparing self-reported optometric dry eye clinical practices in Australia and the United Kingdom: is there scope for practice improvement? Ophthalmic Physiol Opt 2016; 36:140-51. [DOI: 10.1111/opo.12280] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 01/11/2016] [Indexed: 11/28/2022]
|
44
|
Assessing ocular bulbar redness: a comparison of methods. Ophthalmic Physiol Opt 2015; 36:132-9. [PMID: 26890702 DOI: 10.1111/opo.12245] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 08/07/2015] [Indexed: 12/31/2022]
Abstract
PURPOSE We consider whether quantification of ocular bulbar redness, using image processing of relative Red-channel activity (Red-value), can be applied to a clinical sample and how this approach compares to an automated bulbar redness grading technique (Oculus Keratograph 5M, R-scan). METHODS Red-values from dry eye patients (n = 25) were determined using image processing of digital photographs over the nasal bulbar conjunctiva. Red-values were compared with subjective grades from six clinicians who graded the images using the IER scale. We considered the level of agreement between the Red-value and automated bulbar redness scores from the commercial instrument (R-scan). Scoring variability for each technique was assessed using the geometric coefficient of variation (gCoV, %). Agreement between techniques was considered with Bland-Altman analyses. RESULTS Red-values showed a strong linear relationship (R(2) = 0.99) to the R-scan. The Red-value had least variability (gCoV = 0.97%, 95% CI: 0.76-1.35%). The IER grade showed a linear relationship with Red-value (R(2) = 0.99), bound by a floor effect; it did not discriminate changes in redness below a threshold of 1.75 units (Red-value = 33.0%), after which it paralleled the redness returned by the R-scan. Intra-method variability for the redness returned by the R-scan (gCoV = 9.84%, 95% CI: 7.60-13.94%) and IER grades (gCoV = 7.30%, 95% CI: 1.73-10.31%) was similar (p > 0.05). Bland-Altman analysis showed the R-scan was consistently biased towards lower absolute redness scores than the IER. CONCLUSIONS Digital imaging processing, using relative Red-channel activity, was the least variable of the three techniques. The R-scan and IER showed similar intra-observer variability. The linear relationship between R-scan and Red-value suggests that the R-scan could be derived using similar methods.
Collapse
|
45
|
Chronic ocular hypertension induced by circumlimbal suture in rats. Invest Ophthalmol Vis Sci 2015; 56:2811-20. [PMID: 25829414 DOI: 10.1167/iovs.14-16009] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To induce chronic intraocular pressure (IOP) elevation in rat eyes by circumlimbal suture. METHODS Anesthetized (isoflurane) Long-Evans rats underwent unilateral circumlimbal suture implantation while the fellow eyes served as untreated controls (n = 15). A sham group (n = 8) received the same procedure except that the suture was loosely tied. Intraocular pressure, electroretinography (ERG), and optical coherence tomography (OCT) were monitored for 15 weeks, after which retinal histology and immunofluorescence staining for glial fibrillary acidic protein (GFAP) and ionized calcium binding adapter molecule-1 (Iba-1) were undertaken. RESULTS Both IOP and ERG remained unaltered in the sham and all control eyes over 15 weeks. In the ocular hypertensive eye, IOP spiked from 17 ± 1 to 58 ± 3 mm Hg immediately after suture application, recovering to 32 ± 2 mm Hg by 24 hours, and remained elevated by 7 to 10 mm Hg above baseline for 15 weeks. At week 2, there was a small reduction of ERG components involving the photoreceptor a-wave, bipolar cell b-wave, and ganglion cell-mediated scotopic threshold response (pSTR). The reduction in a- and b-wave remained stable, while the pSTR became more affected from week 8 onward (P < 0.05). By week 12, there was progressive retinal nerve fiber layer (RNFL) thinning. At week 15, GFAP expression was upregulated in inner retina and on Müller cells. The ganglion cell dysfunction was associated with RNFL thinning and cell loss in the ganglion cell layer. CONCLUSIONS Circumlimbal suture provides a simple and cost-effective way to induce mild chronic ocular hypertension in rat eyes. This model produces preferential ganglion cell dysfunction and RNFL reduction.
Collapse
|
46
|
Abstract
An increasing number of studies indicate that the optic nerve head of the eye is sensitive not only to changes in intraocular pressure (IOP), but also to intracranial pressure (ICP). This study examines changes to optic nerve and retinal structure in a rat model in response to a range of IOP and ICP levels using optical coherence tomography. Furthermore, we examine the functional sequelae of these structural changes by quantifying the effect of pressure changes on the electroretinogram. IOP elevation (10–90 mmHg) induces progressive deformation of the optic nerve head and retinal surface (P < 0.05), compression of the retina (P < 0.05) and bipolar cell (b-wave), and retinal ganglion cell (scotopic threshold response) dysfunction (P < 0.05). Simultaneously altering ICP (−5 to 30 mmHg) modifies these IOP-induced responses, with lower ICP (−5 mmHg) exacerbating and higher ICP (15–30 mmHg) ameliorating structural and functional deficits. Thus, the balance between IOP and ICP (optic nerve pressure gradient, ONPG = IOP − ICP) plays an important role in optic nerve integrity. Structural and functional parameters exhibit a two-phase relationship to ONPG, with structural changes being more sensitive to ONPG modification (threshold = −0.6 to 11.3 mmHg) compared with functional changes (threshold = 49.7–54.6 mmHg). These findings have implications for diseases including glaucoma, intracranial hypertension, and long-term exposure to microgravity.
Collapse
|
47
|
Clinical impact of migraine for the management of glaucoma patients. Prog Retin Eye Res 2015; 51:107-24. [PMID: 26232725 DOI: 10.1016/j.preteyeres.2015.07.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 07/23/2015] [Accepted: 07/27/2015] [Indexed: 12/19/2022]
Abstract
Migraine is a common and debilitating primary headache disorder that affects 10-15% of the general population, particularly people of working age. Migraine is relevant to providers of clinical eye-care because migraine attacks are associated with a range of visual sensory symptoms, and because of growing evidence that the results of standard tests of visual function necessary for the diagnosis and monitoring of glaucoma (visual fields, electrophysiology, ocular imaging) can be abnormal due to migraine. These abnormalities are measureable in-between migraine events (the interictal period), despite patients being asymptomatic and otherwise healthy. This picture is further complicated by epidemiological data that suggests an increased prevalence of migraine in patients with glaucoma, particularly in patients with normal tension glaucoma. We discuss how migraine, as a co-morbidity, can confound the results and interpretation of clinical tests that form part of contemporary glaucoma evaluation, and provide practical evidence-based recommendations for the clinical testing and management of patients with migraine who attend eye-care settings.
Collapse
|
48
|
Abnormal inhibition-excitation imbalance in migraine. Cephalalgia 2015; 36:5-14. [DOI: 10.1177/0333102415576725] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Accepted: 02/02/2015] [Indexed: 12/17/2022]
Abstract
Background People with migraine show increased surround suppression of perceived contrast, a perceptual analogue of centre-surround antagonistic interactions in visual cortex. A proposed mechanism is that cortical ‘hyperexcitability’ or ‘hyperresponsivity’, a prominent theory in the migraine literature, drives abnormal excitatory-inhibitory balance to give increased local inhibition. The purpose of this cross-sectional study was to determine whether cortical hyperresponsivity and excitatory-inhibitory imbalance manifests in the visual cortical response of migraine sufferers. Methods Interictal steady-state visual evoked potentials (VEPs) in response to 0 to 97% contrast were recorded in 30 migraine participants (15 without aura, 15 with aura) and 21 non-headache controls. Monotonicity indices were calculated to determine response saturation or supersaturation. Contrast gain was modelled with a modified saturating hyperbolic function to allow for variation in excitation and inhibition. Results A greater proportion of migraine participants (43%) than controls (14%) exhibited significant VEP supersaturation at high contrast, based on monotonicity index (chi-square, p = 0.028). Supersaturation was also evident by the trend for greater suppressive exponent values in migraine compared to control individuals (Mann-Whitney rank sum, p = 0.075). Conclusions Supersaturation in migraine is consistent with excess excitation (hyperresponsivity) driving increased network inhibition and provides support for excitatory-inhibitory imbalance as a pathophysiological disturbance in migraine.
Collapse
|
49
|
Chronic intraocular pressure elevation impairs autoregulatory capacity in streptozotocin-induced diabetic rat retina. Ophthalmic Physiol Opt 2014; 35:125-34. [PMID: 25529024 DOI: 10.1111/opo.12174] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Accepted: 10/23/2014] [Indexed: 02/03/2023]
Abstract
PURPOSE To assess ocular blood flow responses to acute IOP stress following 4 weeks of chronic IOP elevation in streptozotocin (STZ)-induced diabetic and control rats. We hypothesise that chronic IOP elevation for 4 weeks will further impair blood flow regulation in STZ-induced diabetic rats eyes. METHODS Two weeks following citrate buffer or STZ-injections chronic IOP elevation was induced in Long Evans rats via fortnightly intracameral injections of microspheres (15 μm) suspended in 5% polyethylene glycol. IOP was monitored daily. Electroretinography (ERG, -6.79-2.07 log cd s m(-2) ) was undertaken at Week 4 to compare photoreceptor (RmPIII ), ON-bipolar cell (Vmax ) and ganglion cell dominant ERG [scotopic threshold response (STR)] components. 4 weeks post-chronic IOP induction, ocular blood flow (laser Doppler flowmetry) was measured in response to acute IOP challenge (10-100 mmHg, in 5 mmHg steps, each 3 min). RESULTS Four weeks of chronic IOP (mean ± S.E.M., citrate: 24.0 ± 0.3 to 30.7 ± 1.3 and STZ-diabetes: 24.2 ± 0.2 to 31.1 ± 1.2 mmHg) was associated with reduced photoreceptor amplitude in both groups (-25.3 ± 2.2% and -17.2 ± 3.0%, respectively). STZ-diabetic eyes showed reduced photoreceptor sensitivity (citrate: 0.5 ± 1.8%, STZ-diabetic: -8.1 ± 2.4%). Paradoxically ON-bipolar cell sensitivity was increased, particularly in citrate control eyes (citrate: 166.8 ± 25.9%, STZ-diabetic: 64.8 ± 18.7%). The ganglion cell dominant STR was not significantly reduced in STZ-diabetic rats. Using acute IOP elevation to probe autoregulation, we show that STZ-diabetes impaired autoregulation compared with citrate control animals. The combination of STZ-diabetes and chronic IOP elevation further impaired autoregulation. CONCLUSIONS STZ-diabetes and chronic IOP elevation appear to be additive risk factors for impairment of ocular blood flow autoregulation.
Collapse
|
50
|
Chronic hypertension increases susceptibility to acute IOP challenge in rats. Invest Ophthalmol Vis Sci 2014; 55:7888-95. [PMID: 25370512 DOI: 10.1167/iovs.14-15207] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To consider the effect of chronic arterial hypertension on the susceptibility of the retina to acute IOP challenge. METHODS Anesthetized adult Long-Evans rats with normal (n = 5, receiving saline subcutaneously), chronic high blood pressure (BP) for 4 weeks (n = 15, Angiotensin II subcutaneously), and acute high BP for 1 hour (n = 10, Angiotensin II intravenously) underwent IOP elevation (10-120 mm Hg, 5 mm Hg steps each 3 minutes). During IOP elevation, retinal function and ocular blood flow were monitored with electroretinogram (ERG) and laser-Doppler flowmetry (LDF), respectively. Blood pressure was monitored via a femoral artery cannula. Electroretinogram and LDF responses are expressed as a percentage of baseline and compared between groups. The left ventricle and the aorta were dissected to assess the morphologic changes associated with chronic hypertension. RESULTS Four weeks of hypertension (systolic BP 192 ± 4 mm Hg) produced cardiac hypertrophy and thickened aortic arterial walls compared with controls (systolic BP 112 ± 3 mm Hg). Retinal function was unaltered with chronic hypertension compared with normotensive animals. During acute IOP elevation, ERG and LDF were reduced in a dose-dependent manner in all BP groups. Both chronic and acute hypertension made the ERG and LDF less susceptible to IOP elevation. However, the degree of resistance to IOP elevation was greater in acute hypertension compared with chronic hypertension (P < 0.05). CONCLUSIONS Acute BP elevation makes retinal function and blood flow less susceptible to IOP elevation. The reduced susceptibility afforded by improved ocular perfusion pressure is compromised after 4 weeks of chronic hypertension.
Collapse
|