1
|
The dependency of fetal left ventricular biomechanics function on myocardium helix angle configuration. Biomech Model Mechanobiol 2022; 22:629-643. [PMID: 36550241 PMCID: PMC10097781 DOI: 10.1007/s10237-022-01669-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 12/06/2022] [Indexed: 12/24/2022]
Abstract
The helix angle configuration of the myocardium is understood to contribute to the heart function, as finite element (FE) modeling of postnatal hearts showed that altered configurations affected cardiac function and biomechanics. However, similar investigations have not been done on the fetal heart. To address this, we performed image-based FE simulations of fetal left ventricles (LV) over a range of helix angle configurations, assuming a linear variation of helix angles from epicardium to endocardium. Results showed that helix angles have substantial influence on peak myofiber stress, cardiac stroke work, myocardial deformational burden, and spatial variability of myocardial strain. A good match between LV myocardial strains from FE simulations to those measured from 4D fetal echo images could only be obtained if the transmural variation of helix angle was generally between 110 and 130°, suggesting that this was the physiological range. Experimentally discovered helix angle configurations from the literature were found to produce high peak myofiber stress, high cardiac stroke work, and a low myocardial deformational burden, but did not coincide with configurations that would optimize these characteristics. This may suggest that the fetal development of myocyte orientations depends concurrently on several factors rather than a single factor. We further found that the shape, rather than the size of the LV, determined the manner at which helix angles influenced these characteristics, as this influence changed significantly when the LV shape was varied, but not when a heart was scaled from fetal to adult size while retaining the same shape. This may suggest that biomechanical optimality would be affected during diseases that altered the geometric shape of the LV.
Collapse
|
2
|
Interpreting the role of nuchal fold for fetal growth restriction prediction using machine learning. Sci Rep 2022; 12:3907. [PMID: 35273269 PMCID: PMC8913636 DOI: 10.1038/s41598-022-07883-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 02/25/2022] [Indexed: 11/28/2022] Open
Abstract
The objective of the study is to investigate the effect of Nuchal Fold (NF) in predicting Fetal Growth Restriction (FGR) using machine learning (ML), to explain the model's results using model-agnostic interpretable techniques, and to compare the results with clinical guidelines. This study used second-trimester ultrasound biometry and Doppler velocimetry were used to construct six FGR (birthweight < 3rd centile) ML models. Interpretability analysis was conducted using Accumulated Local Effects (ALE) and Shapley Additive Explanations (SHAP). The results were compared with clinical guidelines based on the most optimal model. Support Vector Machine (SVM) exhibited the most consistent performance in FGR prediction. SHAP showed that the top contributors to identify FGR were Abdominal Circumference (AC), NF, Uterine RI (Ut RI), and Uterine PI (Ut PI). ALE showed that the cutoff values of Ut RI, Ut PI, and AC in differentiating FGR from normal were comparable with clinical guidelines (Errors between model and clinical; Ut RI: 15%, Ut PI: 8%, and AC: 11%). The cutoff value for NF to differentiate between healthy and FGR is 5.4 mm, where low NF may indicate FGR. The SVM model is the most stable in FGR prediction. ALE can be a potential tool to identify a cutoff value for novel parameters to differentiate between healthy and FGR.
Collapse
|
3
|
Ethical considerations of preconception and prenatal gene modification in the embryo and fetus. Hum Reprod 2021; 36:3018-3027. [PMID: 34665851 DOI: 10.1093/humrep/deab222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 09/08/2021] [Indexed: 11/13/2022] Open
Abstract
The National Academies of Sciences and Medicine 2020 consensus statement advocates the reinstatement of research in preconception heritable human genome editing (HHGE), despite the ethical concerns that have been voiced about interventions in the germline, and outlines criteria for its eventual clinical application to address monogenic disorders. However, the statement does not give adequate consideration to alternative technologies. Importantly, it omits comparison to fetal gene therapy (FGT), which involves gene modification applied prenatally to the developing fetus and which is better researched and less ethically contentious. While both technologies are applicable to the same monogenic diseases causing significant prenatal or early childhood morbidity, the benefits and risks of HHGE are distinct from FGT though there are important overlaps. FGT has the current advantage of a wealth of robust preclinical data, while HHGE is nascent technology and its feasibility for specific diseases still requires scientific proof. The ethical concerns surrounding each are unique and deserving of further discussion, as there are compelling arguments supporting research and eventual clinical translation of both technologies. In this Opinion, we consider HHGE and FGT through technical and ethical lenses, applying common ethical principles to provide a sense of their feasibility and acceptability. Currently, FGT is in a more advanced position for clinical translation and may be less ethically contentious than HHGE, so it deserves to be considered as an alternative therapy in further discussions on HHGE implementation.
Collapse
|
4
|
A reasoned approach towards administering COVID-19 vaccines to pregnant women. Prenat Diagn 2021; 41:1018-1035. [PMID: 34191294 PMCID: PMC8362094 DOI: 10.1002/pd.5985] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 05/20/2021] [Accepted: 05/28/2021] [Indexed: 12/24/2022]
Abstract
There are over 50 SARS-CoV-2 candidate vaccines undergoing Phase II and III clinical trials. Several vaccines have been approved by regulatory authorities and rolled out for use in different countries. Due to concerns of potential teratogenicity or adverse effect on maternal physiology, pregnancy has been a specific exclusion criterion for most vaccine trials with only two trials not excluding pregnant women. Thus, other than limited animal studies, gradually emerging development and reproductive toxicity data, and observational data from vaccine registries, there is a paucity of reliable information to guide recommendations for the safe vaccination of pregnant women. Pregnancy is a risk factor for severe COVID-19, especially in women with comorbidities, resulting in increased rates of preterm birth and maternal morbidity. We discuss the major SARS-CoV-2 vaccines, their mechanisms of action, efficacy, safety profile and possible benefits to the maternal-fetal dyad to create a rational approach towards maternal vaccination while anticipating and mitigating vaccine-related complications. Pregnant women with high exposure risks or co-morbidities predisposing to severe COVID-19 infection should be prioritised for vaccination. Those with risk factors for adverse effects should be counselled accordingly. It is essential to support patient autonomy by shared decision-making involving a risk-benefit discussion with the pregnant woman.
Collapse
|
5
|
Machine learning improves early prediction of small-for-gestational-age births and reveals nuchal fold thickness as unexpected predictor. Prenat Diagn 2021; 41:505-516. [PMID: 33462877 DOI: 10.1002/pd.5903] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 01/05/2021] [Accepted: 01/10/2021] [Indexed: 12/18/2022]
Abstract
OBJECTIVE To investigate the performance of the machine learning (ML) model in predicting small-for-gestational-age (SGA) at birth, using second-trimester data. METHODS Retrospective data of 347 patients, consisting of maternal demographics and ultrasound parameters collected between the 20th and 25th gestational weeks, were studied. ML models were applied to different combinations of the parameters to predict SGA and severe SGA at birth (defined as 10th and third centile birth weight). RESULTS Using second-trimester measurements, ML models achieved an accuracy of 70% and 73% in predicting SGA and severe SGA whereas clinical guidelines had accuracies of 64% and 48%. Uterine PI (Ut PI) was found to be an important predictor, corroborating with existing literature, but surprisingly, so was nuchal fold thickness (NF). Logistic regression showed that Ut PI and NF were significant predictors and statistical comparisons showed that these parameters were significantly different in disease. Further, including NF was found to improve ML model performance, and vice versa. CONCLUSION ML could potentially improve the prediction of SGA at birth from second-trimester measurements, and demonstrated reduced NF to be an important predictor. Early prediction of SGA allows closer clinical monitoring, which provides an opportunity to discover any underlying diseases associated with SGA.
Collapse
|
6
|
Biomechanics of Human Fetal Hearts with Critical Aortic Stenosis. Ann Biomed Eng 2020; 49:1364-1379. [PMID: 33175989 PMCID: PMC8058006 DOI: 10.1007/s10439-020-02683-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 10/26/2020] [Indexed: 12/11/2022]
Abstract
Critical aortic stenosis (AS) of the fetal heart causes a drastic change in the cardiac biomechanical environment. Consequently, a substantial proportion of such cases will lead to a single-ventricular birth outcome. However, the biomechanics of the disease is not well understood. To address this, we performed Finite Element (FE) modelling of the healthy fetal left ventricle (LV) based on patient-specific 4D ultrasound imaging, and simulated various disease features observed in clinical fetal AS to understand their biomechanical impact. These features included aortic stenosis, mitral regurgitation (MR) and LV hypertrophy, reduced contractility, and increased myocardial stiffness. AS was found to elevate LV pressures and myocardial stresses, and depending on severity, can drastically decrease stroke volume and myocardial strains. These effects are moderated by MR. AS alone did not lead to MR velocities above 3 m/s unless LV hypertrophy was included, suggesting that hypertrophy may be involved in clinical cases with high MR velocities. LV hypertrophy substantially elevated LV pressure, valve flow velocities and stroke volume, while reducing LV contractility resulted in diminished LV pressure, stroke volume and wall strains. Typical extent of hypertrophy during fetal AS in the clinic, however, led to excessive LV pressure and valve velocity in the FE model, suggesting that reduced contractility is typically associated with hypertrophy. Increased LV passive stiffness, which might represent fibroelastosis, was found to have minimal impact on LV pressures, stroke volume, and wall strain. This suggested that fibroelastosis could be a by-product of the disease progression and does not significantly impede cardiac function. Our study demonstrates that FE modelling is a valuable tool for elucidating the biomechanics of congenital heart disease and can calculate parameters which are difficult to measure, such as intraventricular pressure and myocardial stresses.
Collapse
|
7
|
The Effect of Scaffold Modulus on the Morphology and Remodeling of Fetal Mesenchymal Stem Cells. Front Physiol 2018; 9:1555. [PMID: 30622472 PMCID: PMC6308149 DOI: 10.3389/fphys.2018.01555] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 10/17/2018] [Indexed: 12/17/2022] Open
Abstract
Hydrogel materials have been successfully used as matrices to explore the role of biophysical and biochemical stimuli in directing stem cell behavior. Here, we present our findings on the role of modulus in guiding bone marrow fetal mesenchymal stem cell (BMfMSC) fate determination using semi-synthetic hydrogels made from PEG-fibrinogen (PF). The BMfMSCs were cultivated in the PF for up to 2 weeks to study the influence of matrix modulus (i.e., cross-linking density of the PF) on BMfMSC survival, morphology and integrin expression. Both two-dimensional (2D) and three-dimensional (3D) culture conditions were employed to examine the BMfMSCs as single cells or as cell spheroids. The hydrogel modulus affected the rate of BMfMSC metabolic activity, the integrin expression levels and the cell morphology, both as single cells and as spheroids. The cell seeding density was also found to be an important parameter of the system in that high densities were favorable in facilitating more cell-to-cell contacts that favored higher metabolic activity. Our findings provide important insight about design of a hydrogel scaffold that can be used to optimize the biological response of BMfMSCs for various tissue engineering applications.
Collapse
|
8
|
Altered Placental Chorionic Arterial Biomechanical Properties During Intrauterine Growth Restriction. Sci Rep 2018; 8:16526. [PMID: 30409992 PMCID: PMC6224524 DOI: 10.1038/s41598-018-34834-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 10/24/2018] [Indexed: 12/16/2022] Open
Abstract
Intrauterine growth restriction (IUGR) is a pregnancy complication due to placental dysfunction that prevents the fetus from obtaining enough oxygen and nutrients, leading to serious mortality and morbidity risks. There is no treatment for IUGR despite having a prevalence of 3% in developed countries, giving rise to an urgency to improve our understanding of the disease. Applying biomechanics investigation on IUGR placental tissues can give important new insights. We performed pressure-diameter mechanical testing of placental chorionic arteries and found that in severe IUGR cases (RI > 90th centile) but not in IUGR cases (RI < 90th centile), vascular distensibility was significantly increased from normal. Constitutive modeling demonstrated that a simplified Fung-type hyperelastic model was able to describe the mechanical properties well, and histology showed that severe IUGR had the lowest collagen to elastin ratio. To demonstrate that the increased distensibility in the severe IUGR group was related to their elevated umbilical resistance and pulsatility indices, we modelled the placental circulation using a Windkessel model, and demonstrated that vascular compliance (and not just vascular resistance) directly affected blood flow pulsatility, suggesting that it is an important parameter for the disease. Our study showed that biomechanics study on placenta could extend our understanding on placenta physiology.
Collapse
|
9
|
Abstract
Studies have suggested the effect of blood flow forces in pathogenesis and progression of some congenital heart malformations. It is therefore of interest to study the fluid mechanic environment of the malformed prenatal heart, such as the tetralogy of Fallot (TOF), especially when little is known about fetal TOF. In this study, we performed patient-specific ultrasound-based flow simulations of three TOF and seven normal human fetal hearts. TOF right ventricles (RVs) had smaller end-diastolic volumes (EDVs) but similar stroke volumes (SVs), whereas TOF left ventricles (LVs) had similar EDVs but slightly increased SVs compared with normal ventricles. Simulations showed that TOF ventricles had elevated systolic intraventricular pressure gradient (IVPG) and required additional energy for ejection but IVPG elevations were considered to be mild relative to arterial pressure. TOF RVs and LVs had similar pressures because of equalization via ventricular septal defect (VSD). Furthermore, relative to normal, TOF RVs had increased diastolic wall shear stresses (WSS) but TOF LVs were not. This was caused by high tricuspid inflow that exceeded RV SV, leading to right-to-left shunting and chaotic flow with enhanced vorticity interaction with the wall to elevate WSS. Two of the three TOF RVs but none of the LVs had increased thickness. As pressure elevations were mild, we hypothesized that pressure and WSS elevation could play a role in the RV thickening, among other causative factors. Finally, the endocardium surrounding the VSD consistently experienced high WSS because of RV-to-LV flow shunt and high flow rate through the over-riding aorta. NEW & NOTEWORTHY Blood flow forces are thought to cause congenital heart malformations and influence disease progression. We performed novel investigations of intracardiac fluid mechanics of tetralogy of Fallot (TOF) human fetal hearts and found essential differences from normal hearts. The TOF right ventricle (RV) and left ventricle had similar and elevated pressure but only the TOF RV had elevated wall shear stress because of elevated tricuspid inflow, and this may contribute to the observed RV thickening. TOF hearts also expended more energy for ejection.
Collapse
|
10
|
Characterization of the hemodynamic wall shear stresses in human umbilical vessels from normal and intrauterine growth restricted pregnancies. Biomech Model Mechanobiol 2018; 17:1107-1117. [PMID: 29691766 DOI: 10.1007/s10237-018-1017-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 04/13/2018] [Indexed: 12/13/2022]
Abstract
Significant reductions in blood flow and umbilical diameters were reported in pregnancies affected by intrauterine growth restriction (IUGR) from placental insufficiency. However, it is not known if IUGR umbilical blood vessels experience different hemodynamic wall shear stresses (WSS) compared to normal umbilical vessels. As WSS is known to influence vasoactivity and vascular growth and remodeling, which can regulate flow rates, it is important to study this parameter. In this study, we aim to characterize umbilical vascular WSS environment in normal and IUGR pregnancies, and evaluate correlation between WSS and vascular diameter, and gestational age. Twenty-two normal and 21 IUGR pregnancies were assessed via ultrasound between the 27th and 39th gestational week. IUGR was defined as estimated fetal weight and/or abdominal circumference below the 10th centile, with no improvement during the remainder of the pregnancy. Vascular diameter was determined by 3D ultrasound scans and image segmentation. Umbilical artery (UA) WSS was computed via computational flow simulations, while umbilical vein (UV) WSS was computed via the Poiseuille equation. Univariate multiple regression analysis was used to test for the differences between normal and IUGR cohort. UV volumetric flow rate, UA and UV diameters were significantly lower in IUGR fetuses, but flow velocities and WSS trends in UA and UV were very similar between normal and IUGR groups. In both groups, UV WSS showed a significant negative correlation with diameter, but UA WSS had no correlation with diameter, suggesting a constancy of WSS environment and the existence of WSS homeostasis in UA, but not in UV. Despite having reduced flow rate and vascular sizes, IUGR UAs had hemodynamic mechanical stress environments and trends that were similar to those in normal pregnancies. This suggested that endothelial dysfunction or abnormal mechanosensing was unlikely to be the cause of small vessels in IUGR umbilical cords.
Collapse
|
11
|
Motorizing and Optimizing Ultrasound Strain Elastography for Detection of Intrauterine Growth Restriction Pregnancies. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:532-543. [PMID: 29329688 DOI: 10.1016/j.ultrasmedbio.2017.12.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 10/29/2017] [Accepted: 12/03/2017] [Indexed: 06/07/2023]
Abstract
Intrauterine growth restriction is a prevalent disease in pregnancy in which placental insufficiency leads to 5 to 10 times higher mortality and lifelong morbidities. The current detection rate is poor, and recently, ultrasound strain elastography (USEL) was proposed as a new diagnostic technique. Currently, placental USEL uses maternal subcutaneous fat as the reference layer, but this is not ideal as fat tissue stiffness can vary widely between subjects. Current USEL also uses manual palpation, and under different compression depths and rates, viscoelastic tissues such as placenta can yield different stiffness results. In the study described here, we strove to improve placental USEL by (i) using an external polymeric pad of known stiffness as the reference layer and (ii) adopting motorized control of the transducer during USEL to standardize palpation motion. Results indicated that motorized USEL reduced measurement variability by 67% compared with freehand USEL. Satisfactory and statistically significant correlations between USEL measurements and mechanical testing validation results were obtained for our new USEL protocol. Placental tissues were found to be non-linear and viscoelastic in nature and, thus, differed in stiffness at different compression rates and depths. Our study also revealed that there was a specific compression depth and rate during USEL that provided better correlation to mechanical testing, and should be considered in clinical placental USEL.
Collapse
|
12
|
Peristaltic-Like Motion of the Human Fetal Right Ventricle and its Effects on Fluid Dynamics and Energy Dynamics. Ann Biomed Eng 2017; 45:2335-2347. [DOI: 10.1007/s10439-017-1886-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Accepted: 07/11/2017] [Indexed: 10/19/2022]
|
13
|
Fluid mechanics of human fetal right ventricles from image-based computational fluid dynamics using 4D clinical ultrasound scans. Am J Physiol Heart Circ Physiol 2016; 311:H1498-H1508. [DOI: 10.1152/ajpheart.00400.2016] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Accepted: 09/08/2016] [Indexed: 11/22/2022]
Abstract
There are 0.6–1.9% of US children who were born with congenital heart malformations. Clinical and animal studies suggest that abnormal blood flow forces might play a role in causing these malformation, highlighting the importance of understanding the fetal cardiovascular fluid mechanics. We performed computational fluid dynamics simulations of the right ventricles, based on four-dimensional ultrasound scans of three 20-wk-old normal human fetuses, to characterize their flow and energy dynamics. Peak intraventricular pressure gradients were found to be 0.2–0.9 mmHg during systole, and 0.1–0.2 mmHg during diastole. Diastolic wall shear stresses were found to be around 1 Pa, which could elevate to 2–4 Pa during systole in the outflow tract. Fetal right ventricles have complex flow patterns featuring two interacting diastolic vortex rings, formed during diastolic E wave and A wave. These rings persisted through the end of systole and elevated wall shear stresses in their proximity. They were observed to conserve ∼25.0% of peak diastolic kinetic energy to be carried over into the subsequent systole. However, this carried-over kinetic energy did not significantly alter the work done by the heart for ejection. Thus, while diastolic vortexes played a significant role in determining spatial patterns and magnitudes of diastolic wall shear stresses, they did not have significant influence on systolic ejection. Our results can serve as a baseline for future comparison with diseased hearts.
Collapse
|
14
|
Characterization of the in vivo wall shear stress environment of human fetus umbilical arteries and veins. Biomech Model Mechanobiol 2016; 16:197-211. [DOI: 10.1007/s10237-016-0810-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 07/20/2016] [Indexed: 10/21/2022]
|
15
|
Mechanical testing and non-linear viscoelastic modelling of the human placenta in normal and growth restricted pregnancies. J Biomech 2016; 49:173-84. [DOI: 10.1016/j.jbiomech.2015.11.055] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Revised: 10/20/2015] [Accepted: 11/25/2015] [Indexed: 02/07/2023]
|
16
|
Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans. Biomech Model Mechanobiol 2015; 15:1159-72. [DOI: 10.1007/s10237-015-0750-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Accepted: 12/01/2015] [Indexed: 11/28/2022]
|