Technical note: A simple method for patient-specific quality assurance for lateral targets on a 1.5 T MR-Linac. J Appl Clin Med Phys 2024; 25:e14323. [PMID: 38426612 PMCID: PMC11005970 DOI: 10.1002/acm2.14323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 03/02/2024] Open
Abstract
The Elekta Unity magnetic resonance (MR) linac is limited to longitudinal couch motion and a sagittal-only laser, which restricts the ability to perform patient-specific quality assurance (PSQA) intensity-modulated radiotherapy (IMRT) measurements for very lateral targets. This work introduces a simple method to perform PSQA using the Sun Nuclear ArcCheck-MR phantom at left and right lateral positions without additional equipment or in-house construction. The proposed setup places the center of the phantom 1.3 cm vertical and 12.9 cm lateral to isocenter in either the left or right direction. Computed tomography (CT) scans are used to simulate the setup and create a QA plan template in the Monaco treatment planning system (TPS). The workflow is demonstrated for four patients, with an average axial distance from the center of the bore to the planning target volume (PTV) of 12.4 cm. Gamma pass rates were above 94% for all plans using global 3%/2 mm gamma criterion with a 10% threshold. Setup uncertainties are slightly larger for the proposed lateral setup compared to the centered setup on the Elekta platform (∼1 mm compared to ∼0.5 mm), but acceptable pass rates are achievable without optimizing shifts in the gamma analysis software. In general, adding the left and right lateral positions increases the axial area in the bore encompassed by the cylindrical measurement array by 147%, substantially increasing the flexibility of measurements for offset targets. Based on this work, we propose using the lateral QA setup if the closest distance to the PTV edge from isocenter is larger than the array radius (10.5 cm) or the percent of the PTV encompassed by the diode array would be increased with the lateral setup compared to the centered setup.
Collapse
|
2
|
Radiation effects on retinal layers revealed by OCT, OCT-A, and perimetry as a function of dose and time from treatment. Sci Rep 2024; 14:3380. [PMID: 38336828 PMCID: PMC10858219 DOI: 10.1038/s41598-024-53830-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 02/05/2024] [Indexed: 02/12/2024] Open
Abstract
Optical coherence tomography (OCT) has become a key method for diagnosing and staging radiation retinopathy, based mainly on the presence of fluid in the central macula. A robust retinal layer segmentation method is required for identification of the specific layers involved in radiation-induced pathology in individual eyes over time, in order to determine damage driven by radiation injury to the microvessels and to the inner retinal neurons. Here, we utilized OCT, OCT-angiography, visual field testing, and patient-specific dosimetry models to analyze abnormal retinal layer thickening and thinning relative to microvessel density, visual function, radiation dose, and time from radiotherapy in a cross-sectional cohort of uveal melanoma patients treated with 125I-plaque brachytherapy. Within the first 24 months of radiotherapy, we show differential thickening and thinning of the two inner retinal layers, suggestive of microvessel leakage and neurodegeneration, mostly favoring thickening. Four out of 13 eyes showed decreased inner retinal capillary density associated with a corresponding normal inner retinal thickness, indicating early microvascular pathology. Two eyes showed the opposite: significant inner retinal layer thinning and normal capillary density, indicating early neuronal damage preceding a decrease in capillary density. At later time points, inner retinal thinning becomes the dominant pathology and correlates significantly with decreased vascularity, vision loss, and dose to the optic nerve. Stable multiple retinal layer segmentation provided by 3D graph-based methods aids in assessing the microvascular and neuronal response to radiation, information needed to target therapeutics for radiation retinopathy and vision loss.
Collapse
|
3
|
A Technique to Enable Efficient Adaptive Radiation Therapy: Automated Contouring of Prostate and Adjacent Organs. Adv Radiat Oncol 2024; 9:101336. [PMID: 38260219 PMCID: PMC10801646 DOI: 10.1016/j.adro.2023.101336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 07/31/2023] [Indexed: 01/24/2024] Open
Abstract
Purpose The purpose of this work was to investigate the use of a segmentation approach that could potentially improve the speed and reproducibility of contouring during magnetic resonance-guided adaptive radiation therapy. Methods and Materials The segmentation algorithm was based on a hybrid deep neural network and graph optimization approach that also allows rapid user intervention (Deep layered optimal graph image segmentation of multiple objects and surfaces [LOGISMOS] + just enough interaction [JEI]). A total of 115 magnetic resonance-data sets were used for training and quantitative assessment. Expert segmentations were used as the independent standard for the prostate, seminal vesicles, bladder, rectum, and femoral heads for all 115 data sets. In addition, 3 independent radiation oncologists contoured the prostate, seminal vesicles, and rectum for a subset of patients such that the interobserver variability could be quantified. Consensus contours were then generated from these independent contours using a simultaneous truth and performance level estimation approach, and the deviation of Deep LOGISMOS + JEI contours to the consensus contours was evaluated and compared with the interobserver variability. Results The absolute accuracy of Deep LOGISMOS + JEI generated contours was evaluated using median absolute surface-to-surface distance which ranged from a minimum of 0.20 mm for the bladder to a maximum of 0.93 mm for the prostate compared with the independent standard across all data sets. The median relative surface-to-surface distance was less than 0.17 mm for all organs, indicating that the Deep LOGISMOS + JEI algorithm did not exhibit a systematic under- or oversegmentation. Interobserver variability testing yielded a mean absolute surface-to-surface distance of 0.93, 1.04, and 0.81 mm for the prostate, seminal vesicles, and rectum, respectively. In comparison, the deviation of Deep LOGISMOS + JEI from consensus simultaneous truth and performance level estimation contours was 0.57, 0.64, and 0.55 mm for the same organs. On average, the Deep LOGISMOS algorithm took less than 26 seconds for contour segmentation. Conclusions Deep LOGISMOS + JEI segmentation efficiently generated clinically acceptable prostate and normal tissue contours, potentially limiting the need for time intensive manual contouring with each fraction.
Collapse
|
4
|
PETRA: A pencil beam trimming algorithm for analytical proton therapy dose calculations with the dynamic collimation system. Med Phys 2023; 50:7263-7280. [PMID: 37370239 PMCID: PMC10751389 DOI: 10.1002/mp.16559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 05/28/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND The Dynamic Collimation System (DCS) has been shown to produce superior treatment plans to uncollimated pencil beam scanning (PBS) proton therapy using an in-house treatment planning system (TPS) designed for research. Clinical implementation of the DCS requires the development and benchmarking of a rigorous dose calculation algorithm that accounts for pencil beam trimming, performs monitor unit calculations to produce deliverable plans at all beam energies, and is ideally implemented with a commercially available TPS. PURPOSE To present an analytical Pencil bEam TRimming Algorithm (PETRA) for the DCS, with and without its range shifter, implemented in the Astroid TPS (.decimal, Sanford, Florida, USA). MATERIALS PETRA was derived by generalizing an existing pencil beam dose calculation model to account for the DCS-specific effects of lateral penumbra blurring due to the nickel trimmers in two different planes, integral depth dose variation due to the trimming process, and the presence and absence of the range shifter. Tuning parameters were introduced to enable agreement between PETRA and a measurement-validated Dynamic Collimation Monte Carlo (DCMC) model of the Miami Cancer Institute's IBA Proteus Plus system equipped with the DCS. Trimmer position, spot position, beam energy, and the presence or absence of a range shifter were all used as variables for the characterization of the model. The model was calibrated for pencil beam monitor unit calculations using procedures specified by International Atomic Energy Agency Technical Report Series 398 (IAEA TRS-398). RESULTS The integral depth dose curves (IDDs) for energies between 70 MeV and 160 MeV among all simulated trimmer combinations, with and without the ranger shifter, agreed between PETRA and DCMC at the 1%/1 mm 1-D gamma criteria for 99.99% of points. For lateral dose profiles, the median 2-D gamma pass rate for all profiles at 1.5%/1.5 mm was 99.99% at the water phantom surface, plateau, and Bragg peak depths without the range shifter and at the surface and Bragg peak depths with the range shifter. The minimum 1.5%/1.5 mm gamma pass rates for the 2-D profiles at the water phantom surface without and with the range shifter were 98.02% and 97.91%, respectively, and, at the Bragg peak, the minimum pass rates were 97.80% and 97.5%, respectively. CONCLUSION The PETRA model for DCS dose calculations was successfully defined and benchmarked for use in a commercially available TPS.
Collapse
|
5
|
Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy. Biomed Phys Eng Express 2023; 9:10.1088/2057-1976/ad02ff. [PMID: 37832529 PMCID: PMC11128250 DOI: 10.1088/2057-1976/ad02ff] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/13/2023] [Indexed: 10/15/2023]
Abstract
Objective.To integrate a Dynamic Collimation System (DCS) into a pencil beam scanning (PBS) proton therapy system and validate its dosimetric impact.Approach.Uncollimated and collimated treatment fields were developed for clinically relevant targets using an in-house treatment plan optimizer and an experimentally validated Monte Carlo model of the DCS and IBA dedicated nozzle (DN) system. The dose reduction induced by the DCS was quantified by calculating the mean dose in 10- and 30-mm two-dimensional rinds surrounding the target. A select number of plans were then used to experimentally validate the mechanical integration of the DCS and beam scanning controller system through measurements with the MatriXX-PT ionization chamber array and EBT3 film. Absolute doses were verified at the central axis at various depths using the IBA MatriXX-PT and PPC05 ionization chamber.Main results.Simulations demonstrated a maximum mean dose reduction of 12% for the 10 mm rind region and 45% for the 30 mm rind region when utilizing the DCS. Excellent agreement was observed between Monte Carlo simulations, EBT3 film, and MatriXX-PT measurements, with gamma pass rates exceeding 94.9% for all tested plans at the 3%/2 mm criterion. Absolute central axis doses showed an average verification difference of 1.4% between Monte Carlo and MatriXX-PT/PPC05 measurements.Significance.We have successfully dosimetrically validated the delivery of dynamically collimated proton therapy for clinically relevant delivery patterns and dose distributions with the DCS. Monte Carlo simulations were employed to assess dose reductions and treatment planning considerations associated with the DCS.
Collapse
|
6
|
Edge Creep: Increased Pigmentation at the Border of Choroidal Melanomas Treated with Plaque Brachytherapy. Ocul Oncol Pathol 2023; 9:56-61. [PMID: 38376093 PMCID: PMC10821788 DOI: 10.1159/000531006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 05/03/2023] [Indexed: 02/21/2024] Open
Abstract
Introduction There is an increase in pigmentation that occurs in many tumors following plaque brachytherapy for choroidal melanoma. Correctly distinguishing between increased pigment at the tumor border versus true growth is imperative. We performed a retrospective review of patients treated with I-125 brachytherapy for choroidal melanoma at our institution to study this phenomenon. Methods Records were reviewed for all patients undergoing plaque brachytherapy for uveal melanoma for a 5-year period (N = 195). Patients with iris and anterior tumors were excluded. Tumors treated more than 31 days after presentation were excluded. Fundus images for patients with increased pigmentation at any of the borders of the tumor at 6-month follow-up that extended beyond the initial pigmented margin were included (N = 20; 8 F, 12 M). Imaging at the last follow-up was reviewed, and it was confirmed that all tumors involuted appropriately with no evidence of local recurrence. The date of initial exam, time to treatment, and follow-up interval were recorded for each included patient. Results Twenty patients (10%) exhibited increased pigment deposition at any of the borders of the tumor at 6-month follow-up that extended beyond the initial pigmented margin. Average tumor thickness was 3.2 mm (1.3-5.1); average largest tumor basal diameter was 11.6 mm (7-15.5). Average time from diagnosis to treatment was 25 days (17-31). Average length of follow-up was 35 months (16-68). No patient developed recurrence during the duration of follow-up, and 1 patient had developed metastasis. Conclusion We describe the phenomenon of increased pigment deposition, "edge creep," at the borders of choroidal melanomas treated with plaque brachytherapy that gave the appearance of initial tumor growth but then subsequently remained stable over time. It is important that treating ocular oncologists be aware of this phenomenon to avoid unnecessary diagnosis of local recurrence.
Collapse
|
7
|
Design, testing and characterization of a proton central axis alignment device for the Dynamic Collimation System. Biomed Phys Eng Express 2023. [PMID: 37267924 DOI: 10.1088/2057-1976/acdad5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE Proton therapy conformity has improved over the years by evolving from passive scattering to spot scanning delivery technologies with smaller proton beam spot sizes. Ancillary collimation devices, such the Dynamic Collimation System (DCS), further improves high dose conformity by sharpening the lateral penumbra. However, as spot sizes are reduced, collimator positional errors play a significant impact on the dose distributions and hence accurate collimator to radiation field alignment is critical. 
Approach. The purpose of this work was to develop a system to align and verify coincidence between the center of the DCS and the proton beam central axis. The Central Axis Alignment Device (CAAD) is composed of a camera and scintillating screen-based beam characterization system. Within a light-tight box, a 12.3-megapixel camera monitors a P43/Gadox scintillating screen via a 45⁰ first-surface mirror. When a collimator trimmer of the DCS is placed in the uncalibrated center of the field, the proton radiation beam continuously scans a 7x7 cm² square field across the scintillator and collimator trimmer while a 7 second exposure is acquired. From the relative positioning of the trimmer to the radiation field, the true center of the radiation field can be calculated.
Main results. The CAAD can calculate the offset between the proton beam radiation central axis and the DCS central axis within 0.054 mm accuracy and 0.075 mm reproducibility.
Significance. Using the CAAD, the DCS is now able to be aligned accurately to the proton radiation beam central axis and no longer relies on an x-ray source in the gantry head which is only validated to within 1.0 mm of the proton beam.
.
Collapse
|
8
|
Abstract
Image guidance for radiation therapy (RT) has evolved over the last few decades and now is routinely performed using cone-beam computerized tomography (CBCT). Conventional linear accelerators (LINACs) that use CBCT have limited soft tissue contrast, are not able to image the patient's internal anatomy during treatment delivery, and most are not capable of online adaptive replanning. RT delivery systems that use MRI have become available within the last several years and address many of the imaging limitations of conventional LINACs. Herein, the authors review the technical characteristics and advantages of MRI-guided RT as well as emerging clinical outcomes.
Collapse
|
9
|
Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy. Phys Med Biol 2023; 68:055003. [PMID: 36706460 PMCID: PMC9940016 DOI: 10.1088/1361-6560/acb6cd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 01/27/2023] [Indexed: 01/28/2023]
Abstract
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system.Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm3target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film.Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT.Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
Collapse
|
10
|
Postoperative Echography for Optimization of Radiation Dosimetry in Patients with Uveal Melanoma Treated with Plaque Brachytherapy. Ophthalmol Retina 2023:S2468-6530(23)00076-3. [PMID: 36822323 DOI: 10.1016/j.oret.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 02/12/2023] [Accepted: 02/15/2023] [Indexed: 02/23/2023]
Abstract
PURPOSE (1) To describe the technique of postoperative echography to confirm the intended treatment dose to the tumor apex in patients with uveal melanoma treated with plaque brachytherapy. (2) To describe the local tumor control rate and visual outcomes with the brachytherapy strategies used at our institution. DESIGN Retrospective review. SUBJECTS Three hundred and seventy-two consecutive patients with uveal melanoma (small, medium, and large) treated with plaque brachytherapy at the University of Iowa from August 2008 to February 2019. METHODS Patient demographics and tumor characteristics were recorded for each patient. Patients with posterior tumors treated with plaque brachytherapy (n = 355) underwent intraoperative ultrasound to confirm plaque placement, and additional postoperative ultrasound on day 1 to 3 postplaque insertion. In cases where intratumor/episcleral plaque edema or hemorrhage shifted the dose to the prescription point to < 85 Gray (Gy), the duration of plaque brachytherapy was increased to compensate. Statistical analysis was performed to compare variables associated with the need for plaque adjustment. MAIN OUTCOMES MEASURES Variables associated with plaque dose needing to be recalculated, local tumor control, and visual acuity outcomes. RESULTS In 31 (8.3%) cases, postoperative echography showed that the tumor apex had shifted outside the 85 Gy isodose curve, requiring adjustment of the duration of brachytherapy (28 cases) or repositioning of the plaque (3 cases). Collaborative Ocular Melanoma Study tumor size was significantly associated with need to adjust the plaque prescription dose (P = 0.03), with large tumors having the highest rate of adjustment. Tumor thickness was larger in cases requiring plaque adjustment compared with those that were not adjusted (median 4.9 mm vs. 3.0 mm, P < 0.01). Local tumor control was 99% (95% confidence interval, 97%-100%) at 5 years and 99% (95% confidence interval, 97%-100%) at 10 years. The percentage of patients who had experienced a visual acuity decline of ≥ 3 lines of vision or had < 20/200 acuity was 14.9% at 1 year after brachytherapy, 35.3% at 3 years, and 51.6% at 5 years. CONCLUSIONS Postoperative ultrasound performed on postoperative day 1 to 3 after plaque insertion for patients undergoing brachytherapy for uveal melanoma may result in improved local tumor control, particularly in the setting of thicker or larger tumors.
Collapse
|
11
|
Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation. Front Oncol 2023; 12:1086258. [PMID: 36776378 PMCID: PMC9909539 DOI: 10.3389/fonc.2022.1086258] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 12/21/2022] [Indexed: 01/27/2023] Open
Abstract
MRI-linear accelerator (MR-linac) devices have been introduced into clinical practice in recent years and have enabled MR-guided adaptive radiation therapy (MRgART). However, by accounting for anatomical changes throughout radiation therapy (RT) and delivering different treatment plans at each fraction, adaptive radiation therapy (ART) highlights several challenges in terms of calculating the total delivered dose. Dose accumulation strategies-which typically involve deformable image registration between planning images, deformable dose mapping, and voxel-wise dose summation-can be employed for ART to estimate the delivered dose. In MRgART, plan adaptation on MRI instead of CT necessitates additional considerations in the dose accumulation process because MRI pixel values do not contain the quantitative information used for dose calculation. In this review, we discuss considerations for dose accumulation specific to MRgART and in relation to current MR-linac clinical workflows. We present a general dose accumulation framework for MRgART and discuss relevant quality assurance criteria. Finally, we highlight the clinical importance of dose accumulation in the ART era as well as the possible ways in which dose accumulation can transform clinical practice and improve our ability to deliver personalized RT.
Collapse
|
12
|
Reduced blood flow by laser speckle flowgraphy after 125I-plaque brachytherapy for uveal melanoma. BMC Ophthalmol 2022; 22:285. [PMID: 35765019 PMCID: PMC9238054 DOI: 10.1186/s12886-022-02505-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 06/22/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND To determine whether reductions in retinal and choroidal blood flow measured by laser speckle flowgraphy are detected after 125I-plaque brachytherapy for uveal melanoma. METHODS In a cross-sectional study, retinal and choroidal blood flow were measured using laser speckle flowgraphy in 25 patients after treatment with 125I-plaque brachytherapy for uveal melanoma. Flow was analyzed in the peripapillary region by mean blur rate as well as in the entire image area with a novel superpixel-based method. Relationships between measures were determined by Spearman correlation. RESULTS Significant decreases in laser speckle blood flow were observed in both the retinal and choroidal vascular beds of irradiated, but not fellow, eyes. Overall, 24 of 25 patients had decreased blood flow compared to their fellow eye, including 5 of the 6 patients imaged within the first 6 months following brachytherapy. A significant negative correlation between blood flow and time from therapy was present. CONCLUSIONS Decreases in retinal and choroidal blood flow by laser speckle flowgraphy were detected within the first 6 months following brachytherapy. Reduced retinal and choroidal blood flow may be an early indicator of microangiographic response to radiation therapy.
Collapse
|
13
|
Clinical Implementational and Site-Specific Workflows for a 1.5T MR-Linac. J Clin Med 2022; 11:jcm11061662. [PMID: 35329988 PMCID: PMC8954784 DOI: 10.3390/jcm11061662] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/11/2022] [Accepted: 03/15/2022] [Indexed: 01/27/2023] Open
Abstract
MR-guided adaptive radiotherapy (MRgART) provides opportunities to benefit patients through enhanced use of advanced imaging during treatment for many patients with various cancer treatment sites. This novel technology presents many new challenges which vary based on anatomic treatment location, technique, and potential changes of both tumor and normal tissue during treatment. When introducing new treatment sites, considerations regarding appropriate patient selection, treatment planning, immobilization, and plan-adaption criteria must be thoroughly explored to ensure adequate treatments are performed. This paper presents an institution’s experience in developing a MRgART program for a 1.5T MR-linac for the first 234 patients. The paper suggests practical treatment workflows and considerations for treating with MRgART at different anatomical sites, including imaging guidelines, patient immobilization, adaptive workflows, and utilization of bolus.
Collapse
|
14
|
Reducing MRI-guided radiotherapy planning and delivery times via efficient leaf sequencing and segment shape optimization algorithms. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac5299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/07/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Extended treatment session times are an operational limitation in magnetic resonance imaging guided adaptive radiotherapy (MRIgRT). In this study a novel leaf sequencing algorithm called optimal fluence levels (OFL) and an optimization algorithm called pseudo gradient descent (PGD) are evaluated with respect to plan quality, beam complexity, and the ability to reduce treatment session times on the Elekta Unity MRIgRT system. Approach. Ten total patients were evaluated on this Institutional Review Board approved study: three with prostate cancer, three with oligometastases, two with pancreatic cancer, and two with liver cancer. Plans were generated using the clinical Monaco Hyperion optimizer and leaf sequencer and then re-optimized using OFL and PGD (OFL + PGD) while holding all IMRT constraints and planning parameters constant. All plans were normalized to ensure 95% of the PTV received the prescription dose. A paired t-test was used to evaluate statistical significance. Main Results. Plan quality in terms of dosimetric OAR sparing was found to be equivalent between the OFL + PGD and conventional Monaco Hyperion optimizer plans. The OFL + PGD plans had a reduction in optimization time of 51.4% ± 5.0% (p = 0.002) and reduction in treatment delivery time of 10.6% ± 7.5% (p = 0.005). OFL + PGD generated plans had on average 13.2% ± 12.6% fewer multi-leaf collimator (MLC) segments (p = 0.009) and 0.1 ± 0.1 lower plan averaged beam modulation (PM) (p = 0.004) relative to the Monaco Hyperion plans. Significance. The OFL + PGD algorithms more quickly generate Unity treatment plans that are faster to deliver than with the conventional approach and without compromising dosimetric plan quality. This is likely due to a delivery complexity reduction enabled by OFL + PGD relative to the Monaco Hyperion plans.
Collapse
|
15
|
Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy. Biomed Phys Eng Express 2022; 8:10.1088/2057-1976/ac525f. [PMID: 35130520 PMCID: PMC8917788 DOI: 10.1088/2057-1976/ac525f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 02/07/2022] [Indexed: 11/12/2022]
Abstract
Purpose. The Dynamic Collimation System (DCS) is an energy layer-specific collimation device designed to reduce the lateral penumbra in pencil beam scanning proton therapy. The DCS consists of two pairs of nickel trimmers that rapidly and independently move and rotate to intercept the scanning proton beam and an integrated range shifter to treat targets less than 4 cm deep. This work examines the validity of a single aperture approximation to model the DCS, a commonly used approximation in commercial treatment planning systems, as well as higher-order aperture-based approximations for modeling DCS-collimated dose distributions.Methods. An experimentally validated TOPAS/Geant4-based Monte Carlo model of the DCS integrated with a beam model of the IBA pencil beam scanning dedicated nozzle was used to simulate DCS- and aperture-collimated 100 MeV beamlets and composite treatment plans. The DCS was represented by three different aperture approximations: a single aperture placed halfway between the upper and lower trimmer planes, two apertures located at the upper and lower trimmer planes, and four apertures, located at both the upstream and downstream faces of each pair of trimmers. Line profiles and three-dimensional regions of interest were used to evaluate the validity and limitations of the aperture approximations investigated.Results. For pencil beams without a range shifter, minimal differences were observed between the DCS and single aperture approximation. For range shifted beamlets, the single aperture approximation yielded wider penumbra widths (up to 18%) in the X-direction and sharper widths (up to 9.4%) in the Y-direction. For the example treatment plan, the root-mean-square errors (RMSEs) in an overall three-dimensional region of interest were 1.7%, 1.3%, and 1.7% for the single aperture, two aperture, and four aperture models, respectively. If the region of interest only encompasses the lateral edges outside of the target, the resulting RMSEs were 1.7%, 1.1%, and 0.5% single aperture, two aperture, and four aperture models, respectively.Conclusions. Monte Carlo simulations of the DCS demonstrated that a single aperture approximation is sufficient for modeling pristine fields at the Bragg depth while range shifted fields require a higher-order aperture approximation. For the treatment plan considered, the double aperture model performed the best overall, however, the four-aperture model most accurately modeled the lateral field edges at the expense of increased dose differences proximal to and within the target.
Collapse
|
16
|
The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy. Med Phys 2022; 49:2684-2698. [PMID: 35120278 PMCID: PMC9007854 DOI: 10.1002/mp.15523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 11/22/2021] [Accepted: 01/23/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The radiobiological benefits afforded by spatially fractionated (GRID) radiation therapy pairs well with the dosimetric advantages of proton therapy. Inspired by the emergence of energy-layer specific collimators in pencil beam scanning (PBS), this work investigates how the spot spacing and collimation can be optimized to maximize the therapeutic gains of a GRID treatment while demonstrating the integration of a dynamic collimation system (DCS) within a commercial beam line to deliver GRID treatments and experimentally benchmark Monte Carlo calculation methods. METHODS GRID profiles were experimentally benchmarked using a clinical DCS prototype that was mounted to the nozzle of the IBA Dedicated Nozzle system. Integral depth dose (IDD) curves and lateral profiles were measured for uncollimated and GRID-collimated beamlets. A library of collimated GRID dose distributions were simulated by placing beamlets within a specified uniform grid and weighting the beamlets to achieve a volume-averaged tumor cell survival equivalent to an open field delivery. The healthy tissue sparing afforded by the GRID distribution was then estimated across a range of spot spacings and collimation widths, which were later optimized based on the radiosensitivity of the tumor cell line and the nominal spot size of the PBS system. This was accomplished by using validated models of the IBA Universal and Dedicated nozzles. RESULTS Excellent agreement was observed between the measured and simulated profiles. The IDDs matched above 98.7% when analyzed using a 1%/1 mm gamma criteria with some minor deviation observed near the Bragg peak for higher beamlet energies. Lateral profile distributions predicted using Monte Carlo methods agreed well with the measured profiles; a gamma passing rate of 95% or higher was observed for all in-depth profiles examined using a 3%/2 mm criteria. Additional collimation was shown to improve PBS GRID treatments by sharpening the lateral penumbra of the beamlets but creates a tradeoff between enhancing the valley-to-peak ratio of the GRID delivery and the dose-volume effect. The optimal collimation width and spot spacing changed as a function of the tumor cell radiosensitivity, dose, and spot size. In general, a spot spacing below 2.0 cm with a collimation less than 1.0 cm provided a superior dose distribution among the specific cases studied. CONCLUSIONS The ability to customize a GRID dose distribution using different collimation sizes and spot spacings is a useful advantage, especially to maximize the overall therapeutic benefit. In this regard, the capabilities of the DCS, and perhaps alternative dynamic collimators, can be used to enhance GRID treatments. Physical dose models calculated using Monte Carlo methods were experimentally benchmarked in water and were found to accurately predict the respective dose distributions of uncollimated and DCS-collimated GRID profiles. This article is protected by copyright. All rights reserved.
Collapse
|
17
|
Proton therapy needs further technological development to fulfill the promise of becoming a superior treatment modality (compared to photon therapy). J Appl Clin Med Phys 2021; 22:4-11. [PMID: 34730268 PMCID: PMC8598137 DOI: 10.1002/acm2.13450] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 01/10/2021] [Indexed: 12/25/2022] Open
|
18
|
Future mainstream platform for online adaptive radiotherapy will be using on-board MR rather than on-board (CB) CT images. J Appl Clin Med Phys 2021; 22:4-9. [PMID: 34278681 PMCID: PMC8292695 DOI: 10.1002/acm2.13352] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 06/18/2021] [Indexed: 01/18/2023] Open
|
19
|
Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy. Int J Part Ther 2021; 8:73-83. [PMID: 34285937 PMCID: PMC8270095 DOI: 10.14338/ijpt-20-00039.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 10/19/2020] [Indexed: 12/29/2022] Open
Abstract
Purpose The development of collimating technologies has become a recent focus in pencil beam scanning (PBS) proton therapy to improve the target conformity and healthy tissue sparing through field-specific or energy-layer–specific collimation. Given the growing popularity of collimators for low-energy treatments, the purpose of this work was to summarize the recent literature that has focused on the efficacy of collimators for PBS and highlight the development of clinical and preclinical collimators. Materials and Methods The collimators presented in this work were organized into 3 categories: per-field apertures, multileaf collimators (MLCs), and sliding-bar collimators. For each case, the system design and planning methodologies are summarized and intercompared from their existing literature. Energy-specific collimation is still a new paradigm in PBS and the 2 specific collimators tailored toward PBS are presented including the dynamic collimation system (DCS) and the Mevion Adaptive Aperture. Results Collimation during PBS can improve the target conformity and associated healthy tissue and critical structure avoidance. Between energy-specific collimators and static apertures, static apertures have the poorest dose conformity owing to collimating only the largest projection of a target in the beam's eye view but still provide an improvement over uncollimated treatments. While an external collimator increases secondary neutron production, the benefit of collimating the primary beam appears to outweigh the risk. The greatest benefit has been observed for low- energy treatment sites. Conclusion The consensus from current literature supports the use of external collimators in PBS under certain conditions, namely low-energy treatments or where the nominal spot size is large. While many recent studies paint a supportive picture, it is also important to understand the limitations of collimation in PBS that are specific to each collimator type. The emergence and paradigm of energy-specific collimation holds many promises for PBS proton therapy.
Collapse
|
20
|
Temporal Relationship Between Visual Field, Retinal and Microvascular Pathology Following 125I-Plaque Brachytherapy for Uveal Melanoma. Invest Ophthalmol Vis Sci 2021; 62:3. [PMID: 33393969 PMCID: PMC7794259 DOI: 10.1167/iovs.62.1.3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To define the temporal relationship of vascular versus neuronal abnormalities in radiation retinopathy. Methods Twenty-five patients with uveal melanoma treated with brachytherapy and sixteen controls were tested. Functional outcome measures included visual acuity and threshold perimetry (HVF 10-2), while structural outcomes included retinal thickness by OCT and vascular measures by OCT angiography and digital fundus photography. The degree of structural abnormality was determined by intereye asymmetry compared with normal subject asymmetry. Diagnostic sensitivity and specificity of each measure were determined using receiver operating characteristic curves. The relationships between the outcome measures were quantified by Spearman correlation. The effect of time from brachytherapy on visual function, retinal layer thickness, and capillary density was also determined. Results Within the first 2 years of brachytherapy, outcome measures revealed visual field loss and microvascular abnormalities in 38% and 31% of subjects, respectively. After 2 years, they became more prevalent, increasing to 67% and 67%, respectively, as did retinal thinning (50%). Visual field loss, loss of capillary density, and inner retinal thickness were highly correlated with one another. Diagnostic sensitivity and specificity were highest for abnormalities in digital fundus photography, visual field loss within the central 10°, and decrease in vessel density. Conclusions Using quantitative approaches, radiation microvasculopathy and visual field defects were detected earlier than loss of inner retinal structure after brachytherapy. Strong correlations eventually developed between vascular pathology, change in retinal thickness, neuronal dysfunction, and radiation dose. Radiation-induced ischemia seems to be a primary early manifestation of radiation retinopathy preceding visual loss.
Collapse
|
21
|
Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy. Med Phys 2021; 48:3172-3185. [PMID: 33740253 DOI: 10.1002/mp.14846] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 03/11/2021] [Accepted: 03/11/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE The aim of this work was to develop and experimentally validate a Dynamic Collimation Monte Carlo (DCMC) simulation package specifically designed for the simulation of collimators in pencil beam scanning proton therapy (PBS-PT). The DCMC package was developed using the TOPAS Monte Carlo platform and consists of a generalized PBS source model and collimator component extensions. METHODS A divergent point-source model of the IBA dedicated nozzle (DN) at the Miami Cancer Institute (MCI) was created and validated against on-axis commissioning measurements taken at MCI. The beamline optics were mathematically incorporated into the source to model beamlet deflections in the X and Y directions at the respective magnet planes. Off-axis measurements taken at multiple planes in air were used to validate both the off-axis spot size and divergence of the source model. The DCS trimmers were modeled and incorporated as TOPAS geometry extensions that linearly translate and rotate about the bending magnets. To validate the collimator model, a series of integral depth dose (IDD) and lateral profile measurements were acquired at MCI and used to benchmark the DCMC performance for modeling both pristine and range shifted beamlets. The water equivalent thickness (WET) of the range shifter was determined by quantifying the shift in the depth of the 80% dose point distal to the Bragg peak between the range shifted and pristine uncollimated beams. RESULTS A source model of the IBA DN system was successfully commissioned against on- and off-axis IDD and lateral profile measurements performed at MCI. The divergence of the source model was matched through an optimization of the source-to-axis distance and comparison against in-air spot profiles. The DCS model was then benchmarked against collimated IDD and in-air and in-phantom lateral profile measurements. Gamma analysis was used to evaluate the agreement between measured and simulated lateral profiles and IDDs with 1%/1 mm criteria and a 1% dose threshold. For the pristine collimated beams, the average 1%/1 mm gamma pass rates across all collimator configurations investigated were 99.8% for IDDs and 97.6% and 95.2% for in-air and in-phantom lateral profiles. All range shifted collimated IDDs passed at 100% while in-air and in-phantom lateral profiles had average pass rates of 99.1% and 99.8%, respectively. The measured and simulated WET of the polyethylene range shifter was determined to be 40.9 and 41.0 mm, respectively. CONCLUSIONS We have developed a TOPAS-based Monte Carlo package for modeling collimators in PBS-PT. This package was then commissioned to model the IBA DN system and DCS located at MCI using both uncollimated and collimated measurements. Validation results demonstrate that the DCMC package can be used to accurately model other aspects of a DCS implementation via simulation.
Collapse
|
22
|
Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy. Med Phys 2021; 47:5343-5356. [PMID: 33411329 DOI: 10.1002/mp.14453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 08/02/2020] [Accepted: 08/03/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE There has been a growing interest in the development of energy-specific collimators for low-energy pencil beam scanning (PBS) to reduce the lateral penumbra. One particular device that has been the focus of several recent published works is the dynamic collimation system (DCS), which provides energy-specific collimation by intercepting the scanned proton beam as it nears to target edge with a set of orthogonal trimmer blades. While several computational studies have shown that this dynamic collimator can provide additional healthy tissue sparing, there has not been any rigorous experimental work to benchmark the theoretical models used in these initial studies. Therefore, it was the purpose of this work to demonstrate an experimental method that could integrate an experimental prototype with a clinical PBS system and benchmark the Monte Carlo methods that have been used to model the DCS. METHODS An experimental DCS prototype was designed and built in house to actively collimate individual proton beamlets during PBS within a well-characterized experimental setup. Monte Carlo methods were initially used to assess construction tolerances and later benchmarked against measurements, including integral depth dose and lateral asymmetric beamlet profiles. The experimental apparatus and measurement geometry were modeled using MCNP6 benchmarked from measurements performed at the Northwestern Chicago Proton Center. RESULTS Gamma analysis tests were used to evaluate the agreement between the measured and simulated profiles with a strict 1 mm/1% criteria and 5% dose threshold. Excellent agreement was observed between the simulated and measured profiles, which included 1 mm/1% gamma analysis pass rates of at least 100% and 95% for the integral depth dose (IDD) profiles and lateral profiles, respectively. Differences in the relative profile shape were observed experimentally between beamlets collimated on- and off-axis, which was attributed to the partial transmission of the beam through an unfocused collimator. Exposure rates resulting from the activation of the device were monitored with survey meter measurements and were found to agree with Monte Carlo estimates of the exposure rate to within 20%. CONCLUSION A DCS prototype was constructed and integrated into a clinical dose delivery system. While the results of this work are not exhaustive, they demonstrate the effects of beam source divergence, device activation, and beamlet deflection during scanning, which were found to be successfully modeled using Monte Carlo methods and experimentally benchmarked. Excellent agreement was achieved between the simulated and measured lateral spot profiles of collimated beamlets delivered on- and off-axis in PBS. The Monte Carlo models adequately predicted the measured elevated plateau region in the integral depth-dose profiles from the low-energy scatter off the collimators.
Collapse
|
23
|
Stereotactic radiotherapy of appropriately selected meningiomas and metastatic brain tumor beds with gamma knife icon versus volumetric modulated arc therapy. J Appl Clin Med Phys 2020; 21:246-252. [PMID: 33207030 PMCID: PMC7769414 DOI: 10.1002/acm2.13100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 09/23/2020] [Accepted: 09/27/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To determine if the gamma knife icon (GKI) can provide superior stereotactic radiotherapy (SRT) dose distributions for appropriately selected meningioma and post-resection brain tumor bed treatments to volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS Appropriately selected targets were not proximal to great vessels, did not have sensitive soft tissue including organs-at-risk (OARs) within the planning target volume (PTV), and did not have concave tumors containing excessive normal brain tissue. Four of fourteen candidate meningioma patients and six of six candidate patients with brain tumor cavities were considered for this treatment planning comparison study. PTVs were generated for GKI and VMAT by adding 1 mm and 3 mm margins, respectively, to the GTVs. Identical PTV V100% -values were obtained for the GKI and VMAT plans for each patient. Meningioma and tumor bed prescription doses were 52.7-54.0 in 1.7-1.8 Gy fractions and 25 Gy in 5 Gy fractions, respectively. GKI dose rate was 3.735 Gy/min for 16 mm collimators. RESULTS PTV radical dose homogeneity index was 3.03 ± 0.35 for GKI and 1.27 ± 0.19 for VMAT. Normal brain D1% , D5% , and D10% were lower for GKI than VMAT by 45.8 ± 10.9%, 38.9 ± 11.5%, and 35.4 ± 16.5% respectively. All OARs considered received lower maximum doses for GKI than VMAT. GKI and VMAT treatment times for meningioma plans were 12.1 ± 4.13 min and 6.2 ± 0.32 min, respectively, and, for tumor cavities, were 18.1 ± 5.1 min and 11.0 ± 0.56 min, respectively. CONCLUSIONS Appropriately selected meningioma and brain tumor bed patients may benefit from GKI-based SRT due to the decreased normal brain and OAR doses relative to VMAT enabled by smaller margins. Care must be taken in meningioma patient selection for SRT with the GKI, even if they are clinically appropriate for VMAT.
Collapse
|
24
|
Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience. J Appl Clin Med Phys 2020; 21:160-172. [PMID: 32432405 PMCID: PMC7386194 DOI: 10.1002/acm2.12902] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 03/17/2020] [Accepted: 04/16/2020] [Indexed: 12/31/2022] Open
Abstract
MR image-guided radiotherapy has the potential to improve patient care, but integration of an MRI scanner with a linear accelerator adds complexity to the commissioning process. This work describes a single institution experience of commissioning an Elekta Unity MR-linac, including mechanical testing, MRI scanner commissioning, and dosimetric validation. Mechanical testing included multileaf collimator (MLC) positional accuracy, measurement of radiation isocenter diameter, and MR-to-MV coincidence. Key MRI tests included magnetic field homogeneity, geometric accuracy, image quality, and the accuracy of navigator-triggered imaging for motion management. Dosimetric validation consisted of comparison between measured and calculated PDDs and profiles, IMRT measurements, and end-to-end testing. Multileaf collimator positional accuracy was within 1.0 mm, the measured radiation isocenter walkout was 0.20 mm, and the coincidence between MR and MV isocenter was 1.06 mm, which is accounted for in the treatment planning system (TPS). For a 350-mm-diameter spherical volume, the peak-to-peak deviation of the magnetic field homogeneity was 4.44 ppm and the geometric distortion was 0.8 mm. All image quality metrics were within ACR recommendations. Navigator-triggered images showed a maximum deviation of 0.42, 0.75, and 3.0 mm in the target centroid location compared to the stationary target for a 20 mm motion at 10, 15, and 20 breaths per minute, respectively. TPS-calculated PDDs and profiles showed excellent agreement with measurement. The gamma passing rate for IMRT plans was 98.4 ± 1.1% (3%/ 2 mm) and end-to-end testing of adapted plans showed agreement within 0.4% between ion-chamber measurement and TPS calculation. All credentialing criteria were satisfied in an independent end-to-end test using an IROC MRgRT phantom.
Collapse
|
25
|
An investigation into the robustness of dynamically collimated proton therapy treatments. Med Phys 2020; 47:3545-3553. [PMID: 32338770 DOI: 10.1002/mp.14208] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/13/2020] [Accepted: 04/21/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demonstrates a technique that can increase plan robustness while preserving target conformity. METHODS Variability in beam spot and collimator positioning can result in changes to a beamlet's dose distribution and incident fluence. The robustness of the DCPT treatment plans was evaluated for three intracranial treatment sites by modeling treatment variability as normally distributed random variables with standard deviations reflecting a clinical system. The simulated treatment plans were then recalculated and compared against their nominal, idealized dose distribution among several trials. It was hypothesized that a plan's robustness to these delivery variables could be reduced by restricting a trimmer's placement toward a beamlet's central axis during collimation. RESULTS By introducing a minimum trimmer offset of 1.5 mm, the variation of the planning target volume (PTV) D95% coverage was reduced to within 2% of the prescribed dose. The treatment plans with trimmers that were placed within 0.5 mm of a collimated beamlet's central axis resulted in the greatest healthy tissue sparing but deviations as high as 11.4% to the PTV D95% were observed. The nominal conformity of these treatment plans utilizing the 1.5 mm trimmer offset was also well maintained. For each treatment plan studied, the 90% conformity index remained within 6.25% of the conformity index achieved without a minimum trimmer offset, and the D50% of surrounding healthy tissue increased by no more than 3.1 Gy relative to a plan without a trimmer offset. CONCLUSIONS While DCPT can offer a significant reduction in healthy tissue irradiation, the results from this work indicate that special care must be taken to ensure proper PTV coverage amid uncertainties associated with this new treatment modality. A simple approach utilizing a minimum trimmer offset was able to preserve the majority of the target conformity and healthy tissue sparing the DCS technology affords while minimizing the uncertainties in this treatment approach.
Collapse
|
26
|
Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods. Med Phys 2020; 47:2725-2734. [PMID: 32170750 DOI: 10.1002/mp.14139] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 02/20/2020] [Accepted: 03/03/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of off-axis distance due to partial transmission through the collimator. In this work, we quantify the magnitude of these effects and propose a focused dynamic collimation system (DCS) for use in proton therapy spot scanning. METHODS This study was done in silico using a model of the Miami Cancer Institute's (MCI) IBA Proteus Plus system created in Geant4-based TOPAS. The DCS utilizes rectangular nickel trimmers mounted on rotating sliders that move in synchrony with the pencil beam to provide focused collimation at the edge of the target. Using a simplified setup of the DCS, simulations were performed at various off-axis locations corresponding to beam deflection angles ranging from 0° to 2.5°. At each off-axis location, focused (trimmer rotated) and unfocused (trimmer not rotated) simulations were performed. In all simulations, a 4 cm water equivalent thickness range shifter was placed upstream of the collimator, and a voxelized water phantom that scored dose was placed downstream, each with 4 cm airgaps. RESULTS Increasing the beam deflection angle for an unfocused trimmer caused the collimated edge of the beamlet profile to shift 0.08-0.61 mm from the baseline 0° simulation. There was also an increase in low-dose regions on the collimated edge ranging from 14.6% to 192.4%. Lastly, the maximum dose, D max , was 0-5% higher for the unfocused simulations. With a focused trimmer design, the profile shift and dose increases were all eliminated. CONCLUSIONS We have shown that focusing a collimator in spot scanning proton therapy reduces dose at the collimated edge compared to conventional, unfocused collimation devices and presented a simple, mechanical design for achieving focusing for a range of source-to-collimator distances.
Collapse
|
27
|
Commissioning and performance evaluation of RadCalc for the Elekta unity MRI-linac. J Appl Clin Med Phys 2019; 20:54-62. [PMID: 31722133 PMCID: PMC6909114 DOI: 10.1002/acm2.12760] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 10/03/2019] [Accepted: 10/14/2019] [Indexed: 11/15/2022] Open
Abstract
Recent availability of MRI‐guided linear accelerators has introduced a number of clinical challenges, particularly in the context of online plan adaptation. Paramount among these is verification of plan quality prior to patient treatment. Currently, there are no commercial products available for monitor unit verification that fully support the newly FDA cleared Elekta Unity 1.5 T MRI‐linac. In this work, we investigate the accuracy and precision of RadCalc for this purpose, which is a software package that uses a Clarkson integration algorithm for point dose calculation. To this end, 18 IMRT patient plans (186 individual beams) were created and used for RadCalc point dose calculations. In comparison with the primary treatment planning system (Monaco), mean point dose deviations of 0.0 ± 1.0% (n = 18) and 1.7 ± 12.4% (n = 186) were obtained on a per‐plan and per‐beam basis, respectively. The dose plane comparison functionality within RadCalc was found to be highly inaccurate, however, modest improvements could be made by artificially shifting jaws and multi leaf collimator positions to account for the dosimetric shift due to the magnetic field (67.3% vs 96.5% mean 5%/5 mm gamma pass rate).
Collapse
|
28
|
Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents. Phys Med Biol 2019; 64:205025. [PMID: 31484170 DOI: 10.1088/1361-6560/ab416d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The dynamic collimation system (DCS) can be combined with pencil beam scanning proton therapy to deliver highly conformal treatment plans with unique collimation at each energy layer. This energy layer-specific collimation is accomplished through the synchronized motion of four trimmer blades that intercept the proton beam near the target boundary in the beam's eye view. However, the corresponding treatment deliveries come at the cost of additional treatment time since the translational speed of the trimmer is slower than the scanning speed of the proton pencil beam. In an attempt to minimize the additional trimmer sequencing time of each field while still maintaining a high degree of conformity, a novel process utilizing ant colony optimization (ACO) methods was created to determine the most efficient route of trimmer sequencing and beamlet scanning patterns for a collective set of collimated proton beamlets. The ACO process was integrated within an in-house treatment planning system optimizer to determine the beam scanning and DCS trimmer sequencing patterns and compared against an analytical approximation of the trimmer sequencing time should a contour-like scanning approach be assumed instead. Due to the stochastic nature of ACO, parameters where determined so that they could ensure good convergence and an efficient optimization of trimmer sequencing that was faster than an analytical contour-like trimmer sequencing. The optimization process was tested using a set of three intracranial treatment plans which were planned using a custom research treatment planning system and were successfully optimized to reduce the additional trimmer sequencing time to approximately 60 s per treatment field while maintaining a high degree of target conformity. Thus, the novel use of ACO techniques within a treatment planning algorithm has been demonstrated to effectively determine collimation sequencing patterns for a DCS in order to minimize the additional treatment time required for trimmer movement during treatment.
Collapse
|
29
|
Dose point kernels for 2,174 radionuclides. Med Phys 2019; 46:5284-5293. [PMID: 31461537 DOI: 10.1002/mp.13789] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 08/13/2019] [Accepted: 08/16/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Rapid adoption of targeted radionuclide therapy as an oncologic intervention has motivated the development of patient-specific voxel-wise approaches to radiation dosimetry. These approaches often rely on pretabulated dose point kernels for convolution-based calculations; however, these dose kernels are sparse in literature and often have suboptimal characteristics. The purpose of this work was to generate an extensive library of dose point kernels with sufficient size and resolution for general clinical application of voxel-wise dosimetry. METHODS Nuclear data were acquired for 2174 radionuclides from the National Nuclear Data Center (Brookhaven National Laboratory, accessed March 2018). Based on these data, isotropic point sources of radioactivity in water were simulated using Monte Carlo N-Particle transport v6.2 (MCNP6.2, Los Alamos National Laboratory). Simulations were separated by emission type for each radionuclide - photons (γ-rays, x rays), beta particles (positrons, electrons); and discrete electrons (conversion electrons, Auger electrons, Coster-Kronig electrons). Dose was tallied in concentric spherical shells about the point source using an energy deposition pulse-height tally (MCNP *F8 tally). Bins were spaced every 0.1 mm until a radius of 10 cm, and every 1 mm until a radius of 2 m. Positron emissions where treated as electrons for transport, with annihilation photons generated at the origin within the photon simulation. Alpha particle emissions were not simulated since their energy is deposited within ~0.2 mm of the source. Neutron and spallation effects were not considered. A subset of the resultant dose point kernels (11 C, 18 F, 32 P, 52g Mn, 64 Cu, 67 Ga, 89 Sr, 89 Zr, 90 Y, 99m Tc, 111 In, 117m Sn, 123 I, 124 I, 125 I, 131 I, 153 Sm, 177 Lu, 186 Re, 188 Re, 211 As, 212 Pb, 213 Bi, 223 Ra, and 225 Ac) were evaluated for accuracy based on conservation of energy, comparison to kernels in the literature, and statistical precision. RESULTS Among dose point kernels that were manually reviewed, good agreement with previously published dose point kernels was observed. Energy within the kernels was found to be conserved to within 1% of the value expected from nuclear data, suggesting that a radius of 2 m was sufficient to capture the almost all of the energy released during decay for all isotopes considered. Local dosimetric uncertainty, evaluated at the radius of 99% energy deposition, was found to be less than 9% for all radioisotopes evaluated. Rebinning data more coarsely by a factor of 10, similar to what would be done for a clinical dose calculation, results in all evaluated kernels having a relative error of less than 1.1% at R50% , 1.5% at R90% , and 2.7% at R99% (the radius corresponding to 50%, 90%, and 99% of total energy deposition, respectively). The kernels produced in this work have been made freely available (https://zenodo.org/record/2564036). CONCLUSIONS An extensive library of high-resolution radial dose kernels was generated and validated against published data. In addition to enabling patient-specific voxel-wise internal dosimetry by convolution superposition, the generated dose point kernels data may prove useful to the wider health physics community.
Collapse
|
30
|
Technical Note: Optimization of spot and trimmer position during dynamically collimated proton therapy. Med Phys 2019; 46:1922-1930. [PMID: 30740709 DOI: 10.1002/mp.13441] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 02/01/2019] [Accepted: 02/02/2019] [Indexed: 11/05/2022] Open
Abstract
PURPOSE To demonstrate a novel theoretical optimization design which considers beam spot and trimmer positioning in addition to beamlet weighting for dynamically collimated proton therapy (DCPT) treatments. Prior to this, the previous methods of plan optimization used to study this emerging technology relied upon an intuitive selection criterion to fix the trimmers blades for a uniform grid of beam spots before determining the individual beamlet weights. To evaluate the potential benefit from this new optimization design, a treatment planning optimization study was performed in order to compare the algorithm's functionality against the existing methods of plan optimization. MATERIALS AND METHODS A direct parameter optimization (DPO) method was developed to determine beam spot and trimmer positions cohesively with beamlet weighting for DCPT treatment plans. Gradients were numerically determined from applying small adjustments to the aforementioned parameters and quantifying the resulting impact on an objective function. This technique was compared to the conventional trimmer selection algorithm (TSA) which does not optimize spot position concurrently with trimmer position. Both planning methods were used to optimize a set of brain treatment plans, and the resulting dose distributions were compared with dose-volume histogram quantities in addition to target coverage, homogeneity, and conformity metrics. RESULTS An overall improvement to the target conformity and healthy tissue sparing was achieved with DPO over TSA while maintaining an equivalent planning target volume (PTV) coverage index for the three brain patients evaluated in this study. On average, the conformity index improved by 5.5% when utilizing DPO. A similar improvement in reducing the dose to several organs at risk was also noted. CONCLUSION Both the TSA and DPO planning methods can achieve highly conformal treatments with the dynamic collimation system (DCS) technology. However, an improvement in the target conformity and healthy tissue sparing was achieved by simultaneously optimizing beam spot position, trimmer location, and beamlet weights using DPO in comparison to the TSA technique.
Collapse
|
31
|
The commissioning and validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator. J Appl Clin Med Phys 2018; 20:184-193. [PMID: 30525308 PMCID: PMC6333122 DOI: 10.1002/acm2.12507] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 10/30/2018] [Accepted: 11/09/2018] [Indexed: 01/01/2023] Open
Abstract
Accurate beam modeling is essential to help ensure overall accuracy in the radiotherapy process. This study describes our experience with beam model validation of a Monaco treatment planning system on a Versa HD linear accelerator. Data were collected such that Monaco beam models could be generated using three algorithms: collapsed cone (CC) and photon Monte Carlo (MC) for photon beams, and electron Monte Carlo (eMC) for electron beams. Validations are performed on measured percent depth doses (PDDs) and profiles, for open‐field point‐doses in homogenous and heterogeneous media, and for obliquely incident electron beams. Gamma analysis is used to assess the agreement between calculation and measurement for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans, including volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT SBRT). For all relevant conditions, gamma index values below 1 are obtained when comparing Monaco calculated PDDs and profiles with measured data. Point‐doses in a water medium are found to be within 2% agreement of commissioning data in 99.5% and 98.6% of the points computed by MC and CC, respectively. All point‐dose calculations for the eMC algorithm in water are within 4% agreement of measurement, and 92% of measurements are within 3%. In heterogeneous media of air and cortical bone, both CC and MC yielded better than 3% agreement with ion chamber measurements. eMC yielded 3% agreement to measurement downstream of air with oblique beams of up to 27°, 5% agreement distal to bone, and within 4% agreement at extended source to surface distance (SSD) for all electron energies except 6 MeV. The 6‐MeV point of measurement is on a steep dose gradient which may impact the magnitude of discrepancy measured. The average gamma passing rate for IMRT/VMAT plans is 96.9% (±2.1%) and 98.0% (±1.9%) for VMAT SBRT when evaluated using 3%/2 mm criteria. Monaco beam models for the Versa HD linac were successfully commissioned for clinical use.
Collapse
|
32
|
Secondary Neutron Dose From a Dynamic Collimation System During Intracranial Pencil Beam Scanning Proton Therapy: A Monte Carlo Investigation. Int J Radiat Oncol Biol Phys 2018; 103:241-250. [PMID: 30114462 DOI: 10.1016/j.ijrobp.2018.08.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 07/25/2018] [Accepted: 08/04/2018] [Indexed: 01/01/2023]
Abstract
PURPOSE Patients receiving pencil beam scanning (PBS) proton therapy with the addition of a dynamic collimation system (DCS) are potentially subject to an additional neutron dose from interactions between the incident proton beam and the trimmer blades. This study investigates the secondary neutron dose rates for both single-field uniform dose (SFUD) and intensity modulated proton therapy treatments. METHODS AND MATERIALS Secondary neutron dose distributions were calculated for both a dynamically collimated and an uncollimated, dual-field chordoma treatment plan and compared with previously published neutron dose rates from other contemporary scanning treatment modalities. Monte Carlo N-Particle transport code was used to track all primary and secondary particles generated from nuclear reactions within the DCS during treatment through a model of the patient geometry acquired from the computed tomography planning data set. Secondary neutron ambient dose equivalent distributions were calculated throughout the patient using a meshgrid with a tally resolution equivalent to that of the treatment planning computed tomography. RESULTS The median healthy-brain neutron ambient dose equivalent for a dynamically collimated intracranial chordoma treatment plan using a DCS was found to be 0.97 mSv/Gy for the right lateral SFUD field, 1.37 mSv/Gy for the apex SFUD field, and 1.24 mSv/Gy for the composite intensity modulated proton therapy distribution from 2 fields. CONCLUSIONS These results were at least 55% lower than what has been reported for uniform scanning modalities with brass apertures. However, they still reflect an increase in the excess relative risk of secondary cancer incidence compared with an uncollimated PBS treatment using only a graphite range shifter. Regardless, the secondary neutron dose expected from the DCS for these PBS proton therapy treatments appears to be on the order of, or below, what is expected for alternative collimated proton therapy techniques.
Collapse
|
33
|
Implementation of respiratory-gated VMAT on a Versa HD linear accelerator. J Appl Clin Med Phys 2017; 18:152-161. [PMID: 28834109 PMCID: PMC5875827 DOI: 10.1002/acm2.12160] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Revised: 04/07/2017] [Accepted: 06/05/2017] [Indexed: 11/16/2022] Open
Abstract
The accurate delivery of respiratory-gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle. In this study, we present the commissioning process for an Anzai gating system (AZ-733VI) on an Elekta Versa HD linear accelerator and make recommendations for successful clinical implementation. The commissioning tests include central axis dose consistency, profile consistency, gating beam-on/off delay, and comparison of gated versus nongated gamma pass rates for patient-specific quality assurance using four clinically commissioned photon energies: 6 MV, 6 FFF, 10 MV, and 10 FFF. The central axis dose constancy between gated and nongated deliveries was within 0.6% for all energies and the analysis of open field profiles for gated and nongated deliveries showed an agreement of 97.8% or greater when evaluated with a percent difference criteria of 1%. The measurement of the beam-on/off delay was done by evaluating images of a moving ball-bearing phantom triggered by the gating system and average beam-on delays of 0.22-0.29 s were observed. No measurable beam-off delay was present. Measurements of gated VMAT dose distributions resulted in decrements as high as 9% in the gamma passing rate as compared to nongated deliveries when evaluated against the planned dose distribution at 3%/3 mm. By decreasing the dose rate, which decreases the gantry speed during gated delivery, the gamma passing rates of gated and nongated treatments can be made equivalent. We present an empirically derived formula to limit the maximum dose rate during VMAT deliveries and show that by implementing a reduced dose rate, a gamma passing rate of greater than 95% (3%/3 mm) was obtained for all plan measurements.
Collapse
|
34
|
Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment. Med Phys 2017; 43:4693. [PMID: 27487886 DOI: 10.1118/1.4955117] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). METHODS Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam's eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. RESULTS The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%-16.9%) and 5.18% (2.9%-7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%-22.6%) and 8.38% (4.7%-12.0%) for the DCS and fixed aperture plans, respectively. CONCLUSIONS The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.
Collapse
|
35
|
Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation. Med Phys 2016; 43:1421-7. [PMID: 26936726 DOI: 10.1118/1.4942375] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To quantify improvement in target conformity in brain and head and neck tumor treatments resulting from the use of a dynamic collimation system (DCS) with two spot scanning proton therapy delivery systems (universal nozzle, UN, and dedicated nozzle, DN) with median spot sizes of 5.2 and 3.2 mm over a range of energies from 100 to 230 MeV. METHODS Uncollimated and collimated plans were calculated with both UN and DN beam models implemented within our in-house treatment planning system for five brain and ten head and neck datasets in patients previously treated with spot scanning proton therapy. The prescription dose and beam angles from the clinical plans were used for both the UN and DN plans. The average reduction of the mean dose to the 10-mm ring surrounding the target between the uncollimated and collimated plans was calculated for the UN and the DN. Target conformity was analyzed using the mean dose to 1-mm thickness rings surrounding the target at increasing distances ranging from 1 to 10 mm. RESULTS The average reductions of the 10-mm ring mean dose for the UN and DN plans were 13.7% (95% CI: 11.6%-15.7%; p < 0.0001) and 11.5% (95% CI: 9.5%-13.5%; p < 0.0001) across all brain cases and 7.1% (95% CI: 4.4%-9.8%; p < 0.001) and 6.3% (95% CI: 3.7%-9.0%; p < 0.001), respectively, across all head and neck cases. The collimated UN plans were either more conformal (all brain cases and 60% of the head and neck cases) than or equivalent (40% of the head and neck cases) to the uncollimated DN plans. The collimated DN plans offered the highest conformity. CONCLUSIONS The DCS added either to the UN or DN improved the target conformity. The DCS may be of particular interest for sites with UN systems looking for a more economical solution than upgrading the nozzle to improve the target conformity of their spot scanning proton therapy system.
Collapse
|
36
|
Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography. Med Phys 2016; 42:1268-79. [PMID: 25735282 DOI: 10.1118/1.4906206] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. METHODS The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm(3) Radcal(®) thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm(3) calibrated ionization chamber to measure the reference air kerma. RESULTS Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. CONCLUSIONS The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.
Collapse
|
37
|
A method for modeling laterally asymmetric proton beamlets resulting from collimation. Med Phys 2016; 42:1321-34. [PMID: 25735287 DOI: 10.1118/1.4907965] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To introduce a method to model the 3D dose distribution of laterally asymmetric proton beamlets resulting from collimation. The model enables rapid beamlet calculation for spot scanning (SS) delivery using a novel penumbra-reducing dynamic collimation system (DCS) with two pairs of trimmers oriented perpendicular to each other. METHODS Trimmed beamlet dose distributions in water were simulated with MCNPX and the collimating effects noted in the simulations were validated by experimental measurement. The simulated beamlets were modeled analytically using integral depth dose curves along with an asymmetric Gaussian function to represent fluence in the beam's eye view (BEV). The BEV parameters consisted of Gaussian standard deviations (sigmas) along each primary axis (σ(x1),σ(x2),σ(y1),σ(y2)) together with the spatial location of the maximum dose (μ(x),μ(y)). Percent depth dose variation with trimmer position was accounted for with a depth-dependent correction function. Beamlet growth with depth was accounted for by combining the in-air divergence with Hong's fit of the Highland approximation along each axis in the BEV. RESULTS The beamlet model showed excellent agreement with the Monte Carlo simulation data used as a benchmark. The overall passing rate for a 3D gamma test with 3%/3 mm passing criteria was 96.1% between the analytical model and Monte Carlo data in an example treatment plan. CONCLUSIONS The analytical model is capable of accurately representing individual asymmetric beamlets resulting from use of the DCS. This method enables integration of the DCS into a treatment planning system to perform dose computation in patient datasets. The method could be generalized for use with any SS collimation system in which blades, leaves, or trimmers are used to laterally sharpen beamlets.
Collapse
|
38
|
Impact of spot size on plan quality of spot scanning proton radiosurgery for peripheral brain lesions. Med Phys 2015; 41:121705. [PMID: 25471952 DOI: 10.1118/1.4901260] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To determine the plan quality of proton spot scanning (SS) radiosurgery as a function of spot size (in-air sigma) in comparison to x-ray radiosurgery for treating peripheral brain lesions. METHODS Single-field optimized (SFO) proton SS plans with sigma ranging from 1 to 8 mm, cone-based x-ray radiosurgery (Cone), and x-ray volumetric modulated arc therapy (VMAT) plans were generated for 11 patients. Plans were evaluated using secondary cancer risk and brain necrosis normal tissue complication probability (NTCP). RESULTS For all patients, secondary cancer is a negligible risk compared to brain necrosis NTCP. Secondary cancer risk was lower in proton SS plans than in photon plans regardless of spot size (p = 0.001). Brain necrosis NTCP increased monotonically from an average of 2.34/100 (range 0.42/100-4.49/100) to 6.05/100 (range 1.38/100-11.6/100) as sigma increased from 1 to 8 mm, compared to the average of 6.01/100 (range 0.82/100-11.5/100) for Cone and 5.22/100 (range 1.37/100-8.00/100) for VMAT. An in-air sigma less than 4.3 mm was required for proton SS plans to reduce NTCP over photon techniques for the cohort of patients studied with statistical significance (p = 0.0186). Proton SS plans with in-air sigma larger than 7.1 mm had significantly greater brain necrosis NTCP than photon techniques (p = 0.0322). CONCLUSIONS For treating peripheral brain lesions--where proton therapy would be expected to have the greatest depth-dose advantage over photon therapy--the lateral penumbra strongly impacts the SS plan quality relative to photon techniques: proton beamlet sigma at patient surface must be small (<7.1 mm for three-beam single-field optimized SS plans) in order to achieve comparable or smaller brain necrosis NTCP relative to photon radiosurgery techniques. Achieving such small in-air sigma values at low energy (<70 MeV) is a major technological challenge in commercially available proton therapy systems.
Collapse
|
39
|
A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: proof of concept. Med Phys 2015; 41:091701. [PMID: 25186376 DOI: 10.1118/1.4837155] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In the absence of a collimation system the lateral penumbra of spot scanning (SS) dose distributions delivered by low energy proton beams is highly dependent on the spot size. For current commercial equipment, spot size increases with decreasing proton energy thereby reducing the benefit of the SS technique. This paper presents a dynamic collimation system (DCS) for sharpening the lateral penumbra of proton therapy dose distributions delivered by SS. METHODS The collimation system presented here exploits the property that a proton pencil beam used for SS requires collimation only when it is near the target edge, enabling the use of trimmers that are in motion at times when the pencil beam is away from the target edge. The device consists of two pairs of parallel nickel trimmer blades of 2 cm thickness and dimensions of 2 cm×18 cm in the beam's eye view. The two pairs of trimmer blades are rotated 90° relative to each other to form a rectangular shape. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6 m/s2, respectively. The blades travel on curved tracks to match the divergence of the proton source. An algorithm for selecting blade positions is developed to minimize the dose delivered outside of the target, and treatment plans are created both with and without the DCS. RESULTS The snout of the DCS has outer dimensions of 22.6×22.6 cm2 and is capable of delivering a minimum treatment field size of 15×15 cm2. Using currently available components, the constructed system would weigh less than 20 kg. For irregularly shaped fields, the use of the DCS reduces the mean dose outside of a 2D target of 46.6 cm2 by approximately 40% as compared to an identical plan without collimation. The use of the DCS increased treatment time by 1-3 s per energy layer. CONCLUSIONS The spread of the lateral penumbra of low-energy SS proton treatments may be greatly reduced with the use of this system at the cost of only a small penalty in delivery time.
Collapse
|
40
|
Abstract
The use of collimator or aperture may sharpen the lateral dose gradient for spot scanning proton therapy. However, to date, there has not been a standard method to determine the aperture margin for a single field in collimated spot scanning proton therapy. This study describes a theoretical framework to select the optimal aperture margin for a single field, and also presents the spot spacing limit required such that the optimal aperture margin exists. Since, for a proton pencil beam partially intercepted by collimator, the maximum point dose (spot center) shifts away from the original pencil beam central axis, we propose that the optimal margin should be equal to the maximum pencil beam center shift under the condition that spot spacing is small with respect to the maximum pencil beam center shift, which can be numerically determined based on beam modeling data. A test case is presented which demonstrates agreement with the prediction made based on the proposed methods. When apertures are applied in a commercial treatment planning system this method may be implemented.
Collapse
|
41
|
Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy. Phys Med Biol 2014; 59:N187-96. [PMID: 25330783 DOI: 10.1088/0031-9155/59/22/n187] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this work was to investigate the reduction in lateral dose penumbra that can be achieved when using a dynamic collimation system (DCS) for spot scanning proton therapy as a function of two beam parameters: spot size and spot spacing. This is an important investigation as both values impact the achievable dose distribution and a wide range of values currently exist depending on delivery hardware. Treatment plans were created both with and without the DCS for in-air spot sizes (σair) of 3, 5, 7, and 9 mm as well as spot spacing intervals of 2, 4, 6 and 8 mm. Compared to un-collimated treatment plans, the plans created with the DCS yielded a reduction in the mean dose to normal tissue surrounding the target of 26.2-40.6% for spot sizes of 3-9 mm, respectively. Increasing the spot spacing resulted in a decrease in the time penalty associated with using the DCS that was approximately proportional to the reduction in the number of rows in the raster delivery pattern. We conclude that dose distributions achievable when using the DCS are comparable to those only attainable with much smaller initial spot sizes, suggesting that the goal of improving high dose conformity may be achieved by either utilizing a DCS or by improving beam line optics.
Collapse
|
42
|
Development and implementation of an EPID-based method for localizing isocenter. J Appl Clin Med Phys 2012; 13:3965. [PMID: 23149787 PMCID: PMC5718539 DOI: 10.1120/jacmp.v13i6.3965] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2012] [Revised: 07/17/2012] [Accepted: 07/17/2012] [Indexed: 12/03/2022] Open
Abstract
The aim of this study was to develop a phantom and analysis software that could be used to quickly and accurately determine the location of radiation isocenter to an accuracy of less than 1 mm using the EPID (Electronic Portal Imaging Device). The proposed solution uses a collimator setting of 10×10cm2 to acquire EPID images of a new phantom constructed from LEGO blocks. Images from a number of gantry and collimator angles are analyzed by automated analysis software to determine the position of the jaws and center of the phantom in each image. The distance between a chosen jaw and the phantom center is then compared to the same distance measured after a 180° collimator rotation to determine if the phantom is centered in the dimension being investigated. Repeated tests show that the system is reproducibly independent of the imaging session, and calculated offsets of the phantom from radiation isocenter are a function of phantom setup only. Accuracy of the algorithm's calculated offsets were verified by imaging the LEGO phantom before and after applying the calculated offset. These measurements show that the offsets are predicted with an accuracy of approximately 0.3 mm, which is on the order of the detector's pitch. Comparison with a star‐shot analysis yielded agreement of isocenter location within 0.5 mm. Additionally, the phantom and software are completely independent of linac vendor, and this study presents results from two linac manufacturers. A Varian Optical Guidance Platform (OGP) calibration array was also integrated into the phantom to allow calibration of the OGP while the phantom is positioned at radiation isocenter to reduce setup uncertainty in the calibration. This solution offers a quick, objective method to perform isocenter localization as well as laser alignment and OGP calibration on a monthly basis. PACS number: 87.55.Qr
Collapse
|
43
|
The dosimetric impact of heterogeneity corrections in high-dose-rate ¹⁹²Ir brachytherapy for cervical cancer: Investigation of both conventional Point-A and volume-optimized plans. Brachytherapy 2012; 11:515-20. [PMID: 22386723 DOI: 10.1016/j.brachy.2012.01.011] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2011] [Revised: 12/19/2011] [Accepted: 01/16/2012] [Indexed: 11/18/2022]
Abstract
PURPOSE To evaluate the dosimetric impact of heterogeneity corrections on both conventional and volume-optimized high-dose-rate (HDR) ¹⁹²Ir brachytherapy tandem-and-ovoid treatment plans. METHODS AND MATERIALS Both conventional and volume-optimized treatment plans were retrospectively created using eight unique CT data sets. In the volume-optimized plans, the clinical target volume (CTV) and organs-at-risk (rectum, bladder, and sigmoid) were contoured on the CT data sets by a single physician. For each plan, dose calculations representing homogeneous water medium were performed using the Task Group (TG-43) formalism and dose calculations with heterogeneity corrections were performed using a commercially available treatment planning system. RESULTS For the conventional plans, the change in dose between TG-43 and heterogeneity-corrected calculations was assessed for the following points: Point-A (left and right) and International Commission on Radiation Units and Measurements (ICRU) 38 defined rectum and bladder points. It was found that the dose to the ICRU bladder decreased the most (-2.2±0.9%), whereas ICRU rectum (-1.7±0.8%), Point-A right (-1.1±0.4%), and Point-A left (-1.0±0.3%) also showed decreases with heterogeneity-corrected calculations. For the volume-optimized plans, the change in dose between TG-43 and heterogeneity-corrected calculations was assessed for the following dose-volume histogram parameters: D(90) of the CTV and D(2cc) of the rectum, bladder, and sigmoid. It was found that D(90) of the CTV decreased by -1.9±0.7% and D(2cc) decreased by -2.6±1.4%, -1.0±0.4%, and -2.0±0.6% for the rectum, bladder and sigmoid, respectively, with heterogeneity-corrected calculations. CONCLUSIONS Heterogeneity corrections on high-dose rate plans were found to have only a small dosimetric impact over TG-43-based dose calculations for both conventional Point-A and volume-optimized plans.
Collapse
|
44
|
Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification. Med Phys 2010; 37:4620-6. [PMID: 20964180 DOI: 10.1118/1.3476459] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS A 100 mm pencil chamber and standard CT dose index (CTDI) phantoms were used to measure the cone-beam dose index (CBDI). A weighted CBDI (CBDI(W)) was then calculated from these measurements to represent the average volumetric dose in the CTDI phantom. By comparing CBDI(W) to the previously published organ doses, organ dose conversion coefficients were developed. The measured CBDI values were also used as inputs for the ImPACT calculator to estimate organ doses. All CBDI dose measurements were performed on both the Elekta XVI and Varian OBI at three clinically relevant locations: Head, chest, and pelvis. RESULTS The head, chest, and pelvis protocols yielded CBDI(W) values of 0.98, 16.62, and 24.13 mGy for the XVI system and 5.17, 6.14, and 21.57 mGy for the OBI system, respectively. Organ doses estimated with the ImPACT CT dose calculator showed a large range of variation from the previously measured organ doses, demonstrating its limitations for use with CBCT. CONCLUSIONS The organ dose conversion coefficients developed in this work relate CBDI(W) values to organ doses previously measured using the same clinical protocols. Ultimately, these coefficients will allow for the quick estimation of organ doses from routine measurements performed using standard CTDI phantoms and pencil chambers.
Collapse
|
45
|
An organ and effective dose study of XVI and OBI cone-beam CT systems. J Appl Clin Med Phys 2010; 11:3183. [PMID: 20592702 PMCID: PMC5719945 DOI: 10.1120/jacmp.v11i2.3183] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2009] [Accepted: 11/11/2009] [Indexed: 11/23/2022] Open
Abstract
The main purpose of this work was to quantify patient organ doses from the two kilovoltage cone beam computed tomography (CBCT) systems currently available on medical linear accelerators, namely the X‐ray Volumetric Imager (XVI, Elekta Oncology Systems) and the On‐Board Imager (OBI, Varian Medical Systems). Organ dose measurements were performed using a fiber‐optic coupled (FOC) dosimetry system along with an adult male anthropomorphic phantom for three different clinically relevant scan sites: head, chest, and pelvis. The FOC dosimeter was previously characterized at diagnostic energies by Hyer et al. [Med Phys 2009;36(5):1711–16] and a total uncertainty of approximately 4% was found for in‐phantom dose measurements. All scans were performed using current manufacturer‐installed clinical protocols and appropriate bow‐tie filters. A comparison of image quality between these manufacturer‐installed protocols was also performed using a Catphan 440 image quality phantom. Results indicated that for the XVI, the dose to the lens of the eye (1.07 mGy) was highest in a head scan, thyroid dose (19.24 mGy) was highest in a chest scan, and gonad dose (29 mGy) was highest in a pelvis scan. For the OBI, brain dose (3.01 mGy) was highest in a head scan, breast dose (5.34 mGy) was highest in a chest scan, and gonad dose (34.61 mGy) was highest in a pelvis scan. Image quality measurements demonstrated that the OBI provided superior image quality for all protocols, with both better spatial resolution and low‐contrast detectability. The measured organ doses were also used to calculate a reference male effective dose to allow further comparison of the two machines and imaging protocols. The head, chest, and pelvis scans yielded effective doses of 0.04, 7.15, and 3.73 mSv for the XVI, and 0.12, 1.82, and 4.34 mSv for the OBI, respectively. PACS number: 87.57.uq
Collapse
|
46
|
Construction of anthropomorphic phantoms for use in dosimetry studies. J Appl Clin Med Phys 2009; 10:195-204. [PMID: 19692982 PMCID: PMC5720556 DOI: 10.1120/jacmp.v10i3.2986] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2008] [Revised: 04/27/2009] [Accepted: 04/27/2009] [Indexed: 11/23/2022] Open
Abstract
This paper reports on the methodology and materials used to construct anthropomorphic phantoms for use in dosimetry studies, improving on methods and materials previously described by Jones et al. [Med Phys. 2006;33(9):3274-82]. To date, the methodology described has been successfully used to create a series of three different adult phantoms at the University of Florida (UF). All phantoms were constructed in 5 mm transverse slices using materials designed to mimic human tissue at diagnostic photon energies: soft tissue-equivalent substitute (STES), lung tissue-equivalent substitute (LTES), and bone tissue-equivalent substitute (BTES). While the formulation for BTES remains unchanged from the previous epoxy resin compound developed by Jones et al. [Med Phys. 2003;30(8):2072-81], both the STES and LTES were redesigned utilizing a urethane based compound which forms a pliable tissue-equivalent material. These urethane based materials were chosen in part for improved phantom durability and easier accommodation of real-time dosimeters. The production process has also been streamlined with the use of an automated machining system to create molds for the phantom slices from bitmap images based on the original segmented computed tomography (CT) datasets. Information regarding the new tissue-equivalent materials as well as images of the construction process and completed phantom are included.
Collapse
|
47
|
Characterization of a water‐equivalent fiber‐optic coupled dosimeter for use in diagnostic radiology. Med Phys 2009; 36:1711-6. [DOI: 10.1118/1.3116362] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|