1
|
Surgical Treatment for Troublesome Mastoid Cavities: Canal Wall Reconstruction With Bony Obliteration Versus Subtotal Petrosectomy. Otol Neurotol 2024; 45:273-280. [PMID: 38270225 DOI: 10.1097/mao.0000000000004109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
INTRODUCTION A chronically discharging modified radical mastoid cavity may require surgical intervention. We aim to explore two techniques. OBJECTIVE To compare outcomes of subtotal petrosectomy (STP) and canal wall reconstruction with bony obliteration technique (CWR-BOT). STUDY DESIGN Retrospective cohort study. SETTING A tertiary referral center. PATIENTS All patients with a chronically discharging mastoid cavity surgically treated at the Radboud University Medical Center by STP or CWR-BOT in 2015 to 2020, excluding patients with preoperative cholesteatoma. MAIN OUTCOME MEASURES Dry ear rate, audiometry, and rehabilitation. SECONDARY OUTCOME MEASURES Healing time, number of postoperative visits, complications, cholesteatoma, and need for revision surgeries. RESULTS Thirty-four (58%) patients underwent STP, and 25 (42%) CWR-BOT. A dry ear was established in 100% of patients (STP) and 87% (CWR-BOT). The air-bone gap (ABG) increased by 12 dB in STP, and decreased by 11 dB in CWR-BOT. Postoperative ABG of CWR-BOT patients was better when preoperative computed tomography imaging showed aerated middle ear aeration. ABG improvement was higher when ossicular chain reconstruction took place. Mean follow-up time was 32.5 months (STP) versus 40.5 months (CWR-BOT). Healing time was 1.2 months (STP) versus 4.1 months (CWR-BOT). The number of postoperative visits was 2.5 (STP) versus 5 (CWR-BOT). Cholesteatoma was found in 15% (STP) versus 4% (CWR-BOT) of patients. Complication rate was 18% (STP) and 24% (CWR-BOT) with a need for revision in 21% (STP) and 8% (CWR-BOT), including revisions for cholesteatoma. CONCLUSION STP and CWR-BOT are excellent treatment options for obtaining a dry ear in patients with a chronically discharging mastoid cavity. This article outlines essential contributing factors in counseling patients when opting for one or the other. Magnetic resonance imaging with diffusion-weighted imaging follow-up should be conducted at 3 and 5 years postoperatively.
Collapse
|
2
|
The relation between cochlear implant programming levels and speech perception performance in post-lingually deafened adults: a data-driven approach. Eur Arch Otorhinolaryngol 2024; 281:1163-1173. [PMID: 37665345 PMCID: PMC10858098 DOI: 10.1007/s00405-023-08195-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 08/14/2023] [Indexed: 09/05/2023]
Abstract
PURPOSE Programming a cochlear implant (fitting) is an essential part of a user's post-implantation journey, defining how sound will be translated into electrical stimulation and aiming to provide optimal speech perception outcomes. Currently, there are no established, evidence-based guidelines for fitting cochlear implant users, leading to a high degree of variability in fitting practices, users' parameters, and probably outcomes. In this study a data-driven approach is used to retrospectively investigate the relation between cochlear implant fitting parameters and speech perception outcomes in post-lingually deafened adults. METHODS 298 data points corresponding to fitting parameters and speech audiometry test results for the same number of adult, post-lingually deafened, experienced CI users were analyzed. Correlation analysis was performed, after which parameters from the top-scoring and bottom-scoring tertiles were compared via the Mann-Whitney-Wilcoxon u test. RESULTS Weak correlations between dynamic range and speech audiometry outcomes were identified, having p values lower than (albeit close to) 0.05. A significant (p < 0.05) difference in electrical dynamic range (the difference between the minimum and maximum amount of current which may be delivered by each electrode) was found, with top-scoring subjects having on average a wider dynamic range. CONCLUSION The association between dynamic range and speech perception outcomes shown in this retrospective study highlights the need for deeper investigation into evidence-driven fitting. It might be a first step in the direction of evidence-based fitting, minimizing variability in outcomes for cochlear implant users and helping mitigate the issue of unexplained low performance.
Collapse
|
3
|
Human Histology after Structure Preservation Cochlear Implantation via Round Window Insertion. Laryngoscope 2024; 134:945-953. [PMID: 37493203 DOI: 10.1002/lary.30900] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 06/22/2023] [Accepted: 07/05/2023] [Indexed: 07/27/2023]
Abstract
OBJECTIVES Current surgical techniques aim to preserve intracochlear structures during cochlear implant (CI) insertion to maintain residual cochlear function. The optimal technique to minimize damage, however, is still under debate. The aim of this study is to histologically compare insertional trauma and intracochlear tissue formation in humans with a CI implanted via different insertion techniques. METHODS One recent temporal bone from a donor who underwent implantation of a full-length CI (576°) via round window (RW) insertion was compared with nine cases implanted via cochleostomy (CO) or extended round window (ERW) approach. Insertional trauma was assessed on H&E-stained histological sections. 3D reconstructions were generated and virtually re-sectioned to measure intracochlear volumes of fibrosis and neo-ossification. RESULTS The RW insertion case showed electrode translocation via the spiral ligament. 2/9 CO/ERW cases showed no insertional trauma. The total volume of the cochlea occupied by fibro-osseous tissue was 10.8% in the RW case compared with a mean of 30.6% (range 8.7%-44.8%, N = 9) in the CO/ERW cases. The difference in tissue formation in the basal 5 mm of scala tympani, however, was even more pronounced when the RW case (12.3%) was compared with the cases with a CO/ERW approach (mean of 93.8%, range 81% to 100%, N = 9). CONCLUSIONS Full-length CI insertions via the RW can be minimally traumatic at the cochlear base without inducing extensive fibro-osseous tissue formation locally. The current study further supports the hypothesis that drilling of the cochleostomy with damage to the endosteum incites a local tissue reaction. LEVEL OF EVIDENCE 4: Case-control study Laryngoscope, 134:945-953, 2024.
Collapse
|
4
|
Phoneme Training for Adult Cochlear Implant Users: A Review of the Literature and Study Protocol. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2023; 66:5071-5086. [PMID: 37889216 DOI: 10.1044/2023_jslhr-23-00335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
PURPOSE This study describes a protocol for a novel individualized phoneme training program for adult cochlear implant (CI) users, based on individual phoneme confusion errors. The protocol is underpinned by a literature review on phoneme training and a focus group with adult CI users. METHOD After a literature search, five studies were included for review and evaluation of quality and level of evidence. A focus group with experienced adult CI users (n = 7) was then conducted to gain insights into their experiences of auditory training post-implantation and recommendations for future training programs. The knowledge gained from the literature review and focus group was used as the foundation for a novel, individualized phoneme training program for adult CI users, for which the protocol is described in this study. RESULTS A review of the literature shows that phoneme training in adult CI users has variable outcomes for on-task and off-task measures. Overall, the concept of individualized training relates to adaptive difficulty within training tasks and not to tailoring training content to participants' individual needs, as indicated by clinical outcomes. The focus group revealed that participants want to be able to track their training progress, have training content tailored to their individual needs, and expressed a preference for shorter training sessions. CONCLUSIONS Using learnings from a literature review and focus group, this study describes a protocol for a novel, individualized phoneme training program for adult CI users. Study findings from this phoneme training program will be disseminated when available. SUPPLEMENTAL MATERIAL https://doi.org/10.23641/asha.24392863.
Collapse
|
5
|
Variability in clinicians' prediction accuracy for outcomes of adult cochlear implant users. Int J Audiol 2023:1-9. [PMID: 37782308 DOI: 10.1080/14992027.2023.2256973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 09/04/2023] [Indexed: 10/03/2023]
Abstract
OBJECTIVE The variability in outcomes among adult cochlear implant (CI) users poses challenges for clinicians in accurately predicting the benefits of the implant for individual candidates. This study aimed to investigate the accuracy and confidence of clinicians in predicting speech perception outcomes for adult CI users one-year post-implantation. DESIGN Participants were presented with comprehensive information on pre-implantation, one-month post-implantation, and six-month post-implantation data for 10 case studies. The cases encompassed a range of one-year post-implantation phoneme scores, from low performers (27%) to high performers (92%). Participants were tasked with predicting the speech perception outcomes for these cases one year after implantation. STUDY SAMPLE Forty-one clinicians completed the full outcome prediction survey. RESULTS Our findings revealed a significant over-prediction of low performance by clinicians. Interestingly, clinicians tended to predict average performance (73-76% phoneme score) even when provided with information suggesting lower-than-average performance. Most clinicians expressed confidence in their predictions, irrespective of their accuracy. CONCLUSIONS Identifying signs of low performance, particularly in the early post-implantation period, can enable clinicians to implement early interventions. Further research into accurate outcome prediction is essential for managing expectations, providing counselling, increasing CI adoption, and optimising clinical care for both high and low performers.
Collapse
|
6
|
Monitoring Cochlear Health With Intracochlear Electrocochleography During Cochlear Implantation: Findings From an International Clinical Investigation. Ear Hear 2023; 44:358-370. [PMID: 36395515 PMCID: PMC9957964 DOI: 10.1097/aud.0000000000001288] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVES Electrocochleography (ECochG) is emerging as a tool for monitoring cochlear function during cochlear implant (CI) surgery. ECochG may be recorded directly from electrodes on the implant array intraoperatively. For low-frequency stimulation, its amplitude tends to rise or may plateau as the electrode is inserted. The aim of this study was to explore whether compromise of the ECochG signal, defined as a fall in its amplitude of 30% or more during insertion, whether transient or permanent, is associated with poorer postoperative acoustic hearing, and to examine how preoperative hearing levels may influence the ability to record ECochG. The specific hypotheses tested were threefold: (a) deterioration in the pure-tone average of low-frequency hearing at the first postoperative follow-up interval (follow-up visit 1 [FUV1], 4 to 6 weeks) will be associated with compromise of the cochlear microphonic (CM) amplitude during electrode insertion (primary hypothesis); (b) an association is observed at the second postoperative follow-up interval (FUV2, 3 months) (secondary hypothesis 1); and (c) the CM response will be recorded earlier during electrode array insertion when the preoperative high-frequency hearing is better (secondary hypothesis 2). DESIGN International, multi-site prospective, observational, between groups design, targeting 41 adult participants in each of two groups, (compromised CM versus preserved CM). Adult CI candidates who were scheduled to receive a Cochlear Nucleus CI with a Slim Straight or a Slim Modiolar electrode array and had a preoperative audiometric low-frequency average thresholds of ≤80 dB HL at 500, 750, and 1000 Hz in the ear to be implanted, were recruited from eight international implant sites. Pure tone audiometry was measured preoperatively and at postoperative visits (FUV1 and follow-up visit 2 [FUV2]). ECochG was measured during and immediately after the implantation of the array. RESULTS From a total of 78 enrolled individuals (80 ears), 77 participants (79 ears) underwent surgery. Due to protocol deviations, 18 ears (23%) were excluded. Of the 61 ears with ECochG responses, amplitudes were < 1 µV throughout implantation for 18 ears (23%) and deemed "unclear" for classification. EcochG responses >1 µV in 43 ears (55%) were stable throughout implantation for 8 ears and compromised in 35 ears. For the primary endpoint at FUV1, 7/41 ears (17%) with preserved CM had a median hearing loss of 12.6 dB versus 34/41 ears (83%) with compromised CM and a median hearing loss of 26.9 dB ( p < 0.014). In assessing the practicalities of measuring intraoperative ECochG, the presence of a measurable CM (>1 µV) during implantation was dependent on preoperative, low-frequency thresholds, particularly at the stimulus frequency (0.5 kHz). High-frequency, preoperative thresholds were also associated with a measurable CM > 1 µV during surgery. CONCLUSIONS Our data shows that CM drops occurring during electrode insertion were correlated with significantly poorer hearing preservation postoperatively compared to CMs that remained stable throughout the electrode insertion. The practicality of measuring ECochG in a large cohort is discussed, regarding the suggested optimal preoperative low-frequency hearing levels ( < 80 dB HL) considered necessary to obtain a CM signal >1 µV.
Collapse
|
7
|
Exploring neurocognitive factors and brain activation in adult cochlear implant recipients associated with speech perception outcomes-A scoping review. Front Neurosci 2023; 17:1046669. [PMID: 36816114 PMCID: PMC9932917 DOI: 10.3389/fnins.2023.1046669] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 01/05/2023] [Indexed: 02/05/2023] Open
Abstract
Background Cochlear implants (CIs) are considered an effective treatment for severe-to-profound sensorineural hearing loss. However, speech perception outcomes are highly variable among adult CI recipients. Top-down neurocognitive factors have been hypothesized to contribute to this variation that is currently only partly explained by biological and audiological factors. Studies investigating this, use varying methods and observe varying outcomes, and their relevance has yet to be evaluated in a review. Gathering and structuring this evidence in this scoping review provides a clear overview of where this research line currently stands, with the aim of guiding future research. Objective To understand to which extent different neurocognitive factors influence speech perception in adult CI users with a postlingual onset of hearing loss, by systematically reviewing the literature. Methods A systematic scoping review was performed according to the PRISMA guidelines. Studies investigating the influence of one or more neurocognitive factors on speech perception post-implantation were included. Word and sentence perception in quiet and noise were included as speech perception outcome metrics and six key neurocognitive domains, as defined by the DSM-5, were covered during the literature search (Protocol in open science registries: 10.17605/OSF.IO/Z3G7W of searches in June 2020, April 2022). Results From 5,668 retrieved articles, 54 articles were included and grouped into three categories using different measures to relate to speech perception outcomes: (1) Nineteen studies investigating brain activation, (2) Thirty-one investigating performance on cognitive tests, and (3) Eighteen investigating linguistic skills. Conclusion The use of cognitive functions, recruiting the frontal cortex, the use of visual cues, recruiting the occipital cortex, and the temporal cortex still available for language processing, are beneficial for adult CI users. Cognitive assessments indicate that performance on non-verbal intelligence tasks positively correlated with speech perception outcomes. Performance on auditory or visual working memory, learning, memory and vocabulary tasks were unrelated to speech perception outcomes and performance on the Stroop task not to word perception in quiet. However, there are still many uncertainties regarding the explanation of inconsistent results between papers and more comprehensive studies are needed e.g., including different assessment times, or combining neuroimaging and behavioral measures. Systematic review registration https://doi.org/10.17605/OSF.IO/Z3G7W.
Collapse
|
8
|
Force and pressure measurements in temporal bones. Am J Otolaryngol 2021; 42:102859. [PMID: 33440250 DOI: 10.1016/j.amjoto.2020.102859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 12/22/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE Some cochlear implant (CI) patients lose their residual hearing during surgery. Two factors that might play a role in residual hearing loss are the change in intracochlear hydraulic pressure and force on the cochlear wall during electrode insertion. The aim of this study is to investigate whether a difference in peak hydraulic pressure and peak force on the cochlear wall exists during a CI electrode insertion with different insertion techniques. MATERIALS AND METHODS Twenty fresh frozen temporal bones were used. Hydraulic pressure and force on the cochlear wall were recorded during straight electrode insertions with 1) slow versus fast insertion speed, 2) manual versus automatic insertion method and 3) round window approach (RWA) versus extended RWA (ERWA). RESULTS When inserting with a slow compared to a fast insertion speed, the peak hydraulic pressure is 239% (95% CI: 130-399%) higher with a RWA and 58% (95% CI: 6-137%) higher with an ERWA. However, the peak force on the cochlear wall is a factor 29% less (95% CI: 13-43%) with a slow insertion speed. No effect was found of opening and insertion method. CONCLUSIONS As contradictory findings were found for hydraulic pressure and force on the cochlear wall on insertion speed, it remains unclear which insertion speed (slow versus fast) is less traumatic to inner ear structure.
Collapse
|
9
|
Multi-Scale deep learning framework for cochlea localization, segmentation and analysis on clinical ultra-high-resolution CT images. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 191:105387. [PMID: 32109685 DOI: 10.1016/j.cmpb.2020.105387] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 02/07/2020] [Accepted: 02/11/2020] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE Performing patient-specific, pre-operative cochlea CT-based measurements could be helpful to positively affect the outcome of cochlear surgery in terms of intracochlear trauma and loss of residual hearing. Therefore, we propose a method to automatically segment and measure the human cochlea in clinical ultra-high-resolution (UHR) CT images, and investigate differences in cochlea size for personalized implant planning. METHODS 123 temporal bone CT scans were acquired with two UHR-CT scanners, and used to develop and validate a deep learning-based system for automated cochlea segmentation and measurement. The segmentation algorithm is composed of two major steps (detection and pixel-wise classification) in cascade, and aims at combining the results of a multi-scale computer-aided detection scheme with a U-Net-like architecture for pixelwise classification. The segmentation results were used as an input to the measurement algorithm, which provides automatic cochlear measurements (volume, basal diameter, and cochlear duct length (CDL)) through the combined use of convolutional neural networks and thinning algorithms. Automatic segmentation was validated against manual annotation, by the means of Dice similarity, Boundary-F1 (BF) score, and maximum and average Hausdorff distances, while measurement errors were calculated between the automatic results and the corresponding manually obtained ground truth on a per-patient basis. Finally, the developed system was used to investigate the differences in cochlea size within our patient cohort, to relate the measurement errors to the actual variation in cochlear size across different patients. RESULTS Automatic segmentation resulted in a Dice of 0.90 ± 0.03, BF score of 0.95 ± 0.03, and maximum and average Hausdorff distance of 3.05 ± 0.39 and 0.32 ± 0.07 against manual annotation. Automatic cochlear measurements resulted in errors of 8.4% (volume), 5.5% (CDL), 7.8% (basal diameter). The cochlea size varied broadly, ranging between 0.10 and 0.28 ml (volume), 1.3 and 2.5 mm (basal diameter), and 27.7 and 40.1 mm (CDL). CONCLUSIONS The proposed algorithm could successfully segment and analyze the cochlea on UHR-CT images, resulting in accurate measurements of cochlear anatomy. Given the wide variation in cochlear size found in our patient cohort, it may find application as a pre-operative tool in cochlear implant surgery, potentially helping elaborate personalized treatment strategies based on patient-specific, image-based anatomical measurements.
Collapse
|
10
|
Abstract
INTRODUCTION The main idea underlying this paper is that impairments such as deafness are particularly relevant to the extent that they lead to deprivation of capability. Likewise, the impact of healthcare services such as cochlear implants and subsequent rehabilitation can best be inferred from the extent that they protect or restore capability of those affected. METHODS To explore children's post-implant capabilities, we tested two newly developed digital, adaptive child self-report and parent-report questionnaires in 19 deaf children (aged 8-12 years) and their parents during rehabilitation, as well as in 23 age peers with normal hearing. RESULTS Despite the impressive speech-language results that were recorded with cochlear implants, the post-implant capabilities of the deaf children we evaluated differed from those of their hearing peers, with the cochlear implant group appearing particularly disadvantaged in areas such as accessing information, communication, social participation, and participation in school. CONCLUSION Deaf children with cochlear implants who are performing well on linguistic and auditory tests can still experience serious limitations in desired functioning. Our findings suggest that a capability approach may reveal aspects of what is being achieved through rehabilitation that might otherwise remain unnoticed, and that could help to further improve the well-being of our patients.IMPLICATIONS FOR REHABILITATIONOverall, children with cochlear implants appeared disadvantaged in certain capability areas, like accessing information, communication, social participation, and participation in school.It may be worthwhile to also ascertain capabilities in these children, representing a domain not covered by clinical measures, tapping directly into areas that are valuable to the patient.
Collapse
|
11
|
Frequencies of Behavioral Problems Reported by Parents and Teachers of Hearing-Impaired Children With Cochlear Implants. Front Psychol 2019; 10:1591. [PMID: 31379656 PMCID: PMC6646424 DOI: 10.3389/fpsyg.2019.01591] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Accepted: 06/25/2019] [Indexed: 11/13/2022] Open
Abstract
Background: Internalizing and externalizing behavioral problems were frequently reported in profoundly hearing-impaired (HI) children with hearing aids. Due to the positive effect of cochlear implants (CIs) on hearing and language development, a positive effect on behavioral problems was expected. However, there is no consensus about the frequency of behavioral problems in CI children, and studies are often based on one informant with the risk of missing behavioral problems in other contexts. Aims: The first aim of this study was to investigate the frequency of behavioral problems in children with CIs as compared to a hearing normative sample. The second aim was to measure the agreement between the parents' and teachers' rates on the behavioral problem scales. And the third aim was to investigate the relation between speech perception, language skills and the frequencies of reported behavioral problems. Methods: Of 71 CI children, 51% were girls and 49% were boys, and the mean age was 8.6 (SD = 3.3). Behavior was reported by parents using the Child Behavior Checklist (CBCL) and by teachers using the Teacher Report Form (TRF). Frequencies of behavioral problems of CI children (6-16 years) were compared to a normative sample with the chi square test. Parent-teacher agreement was measured with the intraclass correlation coefficient (ICC 2,1). Next CI children were divided into four ability level categories regarding speech perception and language skills. Frequencies of behavioral problems were compared between the categories with the chi square test. Results: Parents and teachers of CI children reported similar frequencies of behavioral problems to the normative sample. Fair to low parent-teacher agreements were found on the behavioral problem scales. A significantly higher frequency of behavioral problems was reported in children with low speech perception and receptive vocabulary at school. Conclusion: Parents and teachers report similar frequencies of behavioral problems children with CIs compared to a hearing normative sample. Children with lower speech perception and language levels are more at risk of developing behavioral problems at school. Adequate speech perception and language levels are found to be protective factors for the development of behavior.
Collapse
|
12
|
|
13
|
Influence of hearing loss and cognitive abilities on language development in CHARGE Syndrome. Am J Med Genet A 2016; 170:2022-30. [PMID: 27145116 DOI: 10.1002/ajmg.a.37692] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 04/14/2016] [Indexed: 11/11/2022]
Abstract
Hearing loss and cognitive delay are frequently occurring features in CHARGE syndrome that may contribute to impaired language development. However, not much is known about language development in patients with CHARGE syndrome. In this retrospective study, hearing loss, cognitive abilities, and language development are described in 50 patients with CHARGE syndrome. After informed consent was given, data were collected from local medical files. Most patients (38.3%; 18/47 patients) had moderate hearing loss (41-70 dB) and 58.5% (24/41 patients) had an IQ below 70. The mean language quotients of the receptive and expressive language were more than one standard deviation below the norm. Both hearing loss and cognitive delay had an influence on language development. Language and cognitive data were not available for all patients, which may have resulted in a pre-selection of patients with a delay. In conclusion, while hearing thresholds, cognitive abilities and language development vary widely in CHARGE syndrome, they are mostly below average. Hearing loss and cognitive delay have a significant influence on language development in children with CHARGE syndrome. To improve our knowledge about and the quality of care we can provide to CHARGE patients, hearing and developmental tests should be performed regularly in order to differentiate between the contributions of hearing loss and cognitive delay to delays in language development, and to provide adequate hearing amplification in the case of hearing loss. © 2016 Wiley Periodicals, Inc.
Collapse
|
14
|
Re: Bone-anchored hearing aids for people with bilateral hearing impairment: a systematic review. Clin Otolaryngol 2013; 38:95-6. [DOI: 10.1111/coa.12059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2012] [Indexed: 11/30/2022]
|
15
|
Variations of endonasal anatomy: relevance for the endoscopic endonasal transsphenoidal approach. Acta Neurochir (Wien) 2010; 152:1015-20. [PMID: 20306338 PMCID: PMC2872017 DOI: 10.1007/s00701-010-0629-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2010] [Accepted: 03/03/2010] [Indexed: 11/24/2022]
Abstract
BACKGROUND The endoscopic endonasal transsphenoidal approach (EETA) to the pituitary is performed by ear, nose, and throat (ENT) surgeons in collaboration with neurosurgeons but also by neurosurgeons alone even though neurosurgeons have not been trained in rhinological surgery. PURPOSE To register the frequency of endonasal anatomical variations and to evaluate whether these variations hinder the progress of EETA and require extra rhinological surgical skills. METHODS A prospective cohort study of 185 consecutive patients receiving an EETA through a binostril approach was performed. All anatomical endonasal variations were noted and the relevance for the progress of surgery evaluated. RESULTS In 48% of patients, anatomical variations were recognized, the majority of which were spinae septi and septum deviations. In 5% of patients, the planned binostril approach had to be converted into a mononostril approach; whereas in 18% of patients with an anatomical variation, a correction had to be performed. There was no difference between the ENT surgeon and the neurosurgeon performing the approach. Complications related to the endonasal phase of the surgery occurred in 3.8%. Fluoroscopy or electromagnetic navigation has been used during 6.5% of the surgeries. CONCLUSION Although endonasal anatomical variations are frequent, they do not pose a relevant obstacle for EETA.
Collapse
|
16
|
|
17
|
Magnetic resonance imaging in patients with meningitis induced hearing loss. Eur Arch Otorhinolaryngol 2009; 266:1229-36. [PMID: 19221779 PMCID: PMC2704951 DOI: 10.1007/s00405-009-0921-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2008] [Accepted: 01/26/2009] [Indexed: 11/25/2022]
Abstract
The aim of this multicentre study was to compare T1 with T2 weighted MRI scans of the labyrinth after meningitis and to investigate whether waiting with scanning improved the reliability of diagnosing an ongoing process such as cochlear osteogenesis. Forty-five patients were included who suffered from meningitis induced hearing loss (radiological imaging <1 year after meningitis). Twenty-one gadolinium enhanced T1 and 45 T2 weighted MRI scans were scored by two radiologists regarding the condition of the labyrinth. These radiological observations were compared with the condition of the cochlea as described during cochlear implantation. A higher percentage of agreement with surgery was found for T2 (both radiologists 73%) than for T1 weighted MRI scans (radiologist 1: 62%, radiologist 2: 67%), but this difference is not significant. There was no significant difference between early (0–3 months) and late (>3 months) scanning, showing that radiological imaging soon after meningitis allows early diagnosis without suffering from a lower agreement with surgical findings.
Collapse
|
18
|
Abstract
The otosclerotic process commonly involves the otic capsule and may cause quite widespread demineralisation which leads to a progressive and often profound bilateral sensorineural hearing loss. In this situation cochlear implantation may be the only effective treatment. This chapter considers the pathology of this hearing loss, the effects of cochlear obliteration on implantation, and the effects of demineralisation of the otic capsule on placement of the electrode and nonauditory stimulation. A study is reported from 4 cochlear implant centres in the UK and the Netherlands of 53 patients with cochlear otosclerosis who received cochlear implantation. The CT features of their petrous bones are presented and a classification of the radiological features suggested. 38% of patients experienced facial nerve stimulation presumably due to spread of current through an otic capsule with lower than usual electrical impedance. The most common rogue electrodes were in the proximity of the geniculate ganglion. These could usually be successfully programmed out of the MAP.
Collapse
|