1
|
Real-time feedback on chest compression efficacy by hands-free carotid Doppler in a porcine model. Resusc Plus 2024; 18:100583. [PMID: 38404755 PMCID: PMC10885784 DOI: 10.1016/j.resplu.2024.100583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/30/2024] [Accepted: 02/08/2024] [Indexed: 02/27/2024] Open
Abstract
Aim Current guidelines for cardiopulmonary resuscitation (CPR) recommend a one-size-fits-all approach in relation to the positioning of chest compressions. We recently developed RescueDoppler, a hands-free Doppler ultrasound device for continuous monitoring of carotid blood flow velocity during CPR. The aim of the present study is to investigate whether RescueDoppler via real-time hemodynamic feedback, could identify both optimal and suboptimal compression positions. Methods In this model of animal cardiac arrest, we induced ventricular fibrillation in five domestic pigs. Manual chest compressions were performed for ten seconds at three different positions on the sternum in random order and repeated six times. We analysed Time Average Velocity (TAV) with chest compression position as a fixed effect and animal, position, and sequential time within animals as random effects. Furthermore, we compared TAV to invasive blood pressure from the contralateral carotid artery. Results We were able to detect changes in TAV when altering positions. The positions with the highest (range 19 to 48 cm/s) and lowest (6-25 cm/s) TAV were identified in all animals, with corresponding peak pressure 50-81 mmHg, and 46-64 mmHg, respectively. Blood flow velocity was, on average, highest at the middle position (TAV 33 cm/s), but with significant variability between animals (SD 2.8) and positions within the same animal (SD 9.3). Conclusion RescueDoppler detected TAV changes during CPR with alternating chest compression positions, identifying the position yielding maximal TAV. Future clinical studies should investigate if RescueDoppler can be used as a real-time hemodynamical feedback device to guide compression position.
Collapse
|
2
|
Automatic Detection and Tracking of Anatomical Landmarks in Transesophageal Echocardiography for Quantification of Left Ventricular Function. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:797-804. [PMID: 38485534 DOI: 10.1016/j.ultrasmedbio.2024.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 01/10/2024] [Accepted: 01/25/2024] [Indexed: 05/01/2024]
Abstract
OBJECTIVE Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE). METHODS We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit. RESULTS Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance. CONCLUSION Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.
Collapse
|
3
|
Automatic assessment of left ventricular function for hemodynamic monitoring using artificial intelligence and transesophageal echocardiography. J Clin Monit Comput 2024; 38:281-291. [PMID: 38280975 DOI: 10.1007/s10877-023-01118-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 12/03/2023] [Indexed: 01/29/2024]
Abstract
We have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery. First, we recorded a set of echocardiographic data, consisting of three consecutive beats of midesophageal two- and four-chamber views. We then altered the patient's hemodynamics by positioning them in anti-Trendelenburg and repeated the recordings. We measured MAPSE manually and used autoMAPSE in all available heartbeats and in four LV walls. To assess the agreement with manual measurements, we used a modified Bland-Altman analysis. To assess the precision of each method, we calculated the least significant change (LSC). Finally, to assess trending ability, we calculated the concordance rates using a four-quadrant plot. We found that autoMAPSE measured MAPSE in almost every set of two- and four-chamber views (feasibility 95%). It took less than a second to measure and average MAPSE over three heartbeats. AutoMAPSE had a low bias (0.4 mm) and acceptable limits of agreement (- 3.7 to 4.5 mm). AutoMAPSE was more precise than manual measurements if it averaged more heartbeats. AutoMAPSE had acceptable trending ability (concordance rate 81%) during hemodynamic alterations. In conclusion, autoMAPSE is feasible as an automatic tool for rapid and quantitative assessment of LV function, indicating its potential for hemodynamic monitoring.
Collapse
|
4
|
Generating 3D images of material microstructures from a single 2D image: a denoising diffusion approach. Sci Rep 2024; 14:6498. [PMID: 38499588 PMCID: PMC10948834 DOI: 10.1038/s41598-024-56910-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 03/12/2024] [Indexed: 03/20/2024] Open
Abstract
Three-dimensional (3D) images provide a comprehensive view of material microstructures, enabling numerical simulations unachievable with two-dimensional (2D) imaging alone. However, obtaining these 3D images can be costly and constrained by resolution limitations. We introduce a novel method capable of generating large-scale 3D images of material microstructures, such as metal or rock, from a single 2D image. Our approach circumvents the need for 3D image data while offering a cost-effective, high-resolution alternative to existing imaging techniques. Our method combines a denoising diffusion probabilistic model with a generative adversarial network framework. To compensate for the lack of 3D training data, we implement chain sampling, a technique that utilizes the 3D intermediate outputs obtained by reversing the diffusion process. During the training phase, these intermediate outputs are guided by a 2D discriminator. This technique facilitates our method's ability to gradually generate 3D images that accurately capture the geometric properties and statistical characteristics of the original 2D input. This study features a comparative analysis of the 3D images generated by our method, SliceGAN (the current state-of-the-art method), and actual 3D micro-CT images, spanning a diverse set of rock and metal types. The results shown an improvement of up to three times in the Frechet inception distance score, a typical metric for evaluating the performance of image generative models, and enhanced accuracy in derived properties compared to SliceGAN. The potential of our method to produce high-resolution and statistically representative 3D images paves the way for new applications in material characterization and analysis domains.
Collapse
|
5
|
Correction: Teacher-student approach for lung tumor segmentation from mixed-supervised datasets. PLoS One 2024; 19:e0298978. [PMID: 38349944 PMCID: PMC10863847 DOI: 10.1371/journal.pone.0298978] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024] Open
Abstract
[This corrects the article DOI: 10.1371/journal.pone.0266147.].
Collapse
|
6
|
Segmental myocardial viability by echocardiography at rest. SCAND CARDIOVASC J 2023; 57:2181390. [PMID: 38095169 DOI: 10.1080/14017431.2023.2181390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 02/12/2023] [Indexed: 02/24/2023]
Abstract
BACKGROUND Myocardial viability assessment adds value to the therapeutic decision-making of patients with ischemic heart disease. In this feasibility study, we investigated whether established echocardiographic measurements of post-systolic shortening (PSS), strain, strain rate and wall motion score (WMS) can discover viable myocardial segments. Our hypothesis is that non-viable myocardial segments are both akinetic and without PSS. METHODS The study population consisted of 26 examinations strictly selected by visible dysfunction. We assessed WMS, strain by speckle tracking and strain rate by tissue Doppler. The segments (16*26 = 416) were categorized into either normokinetic/hypokinetic or akinetic/dyskinetic and whether there was PSS. The reference method was the presence of scar with segmental percentage volume scar fraction >50%, detected by late gadolinium-enhanced cardiovascular magnetic resonance. Agreement with echocardiography was evaluated by Kappa coefficient. RESULTS WMS had Kappa coefficient 0.43 (sensitivity 99%, specificity 35%). Kappa coefficient of strain was 0.28 (sensitivity 98%, specificity 23%). By combining PSS in akinetic segments with WMS and strain, the Kappa coefficient was 0.06 and 0.08 respectively. CONCLUSION Segmental viability was best shown by the presence of systolic function. Post-systolic shortening adds no value to the assessment of segmental myocardial viability.
Collapse
|
7
|
Automated estimation of mitral annular plane systolic excursion by artificial intelligence from 3D ultrasound recordings. Artif Intell Med 2023; 144:102646. [PMID: 37783546 DOI: 10.1016/j.artmed.2023.102646] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 08/22/2023] [Accepted: 08/28/2023] [Indexed: 10/04/2023]
Abstract
Perioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention. To overcome these difficulties, this study presents a robust method for automatic and quantitative monitoring of cardiac function based on 3D transesophageal echocardiography (TEE) B-mode ultrasound recordings of the left ventricle (LV). Such an assessment obtains consistent measurements and can produce a near real-time evaluation of ultrasound imagery. Hence, the presented method is time-saving and results in increased accessibility. The mitral annular plane systolic excursion (MAPSE), characterizing global LV function, is estimated by landmark detection and cardiac view classification of two-dimensional images extracted along the long-axis of the ultrasound volume. MAPSE estimation directly from 3D TEE recordings is beneficial since it removes the need for manual acquisition of cardiac views, hence decreasing the need for interference by physicians. Two convolutional neural networks (CNNs) were trained and tested on acquired ultrasound data of 107 patients, and MAPSE estimates were compared to clinically obtained references in a blinded study including 31 patients. The proposed method for automatic MAPSE estimation had low bias and low variability in comparison to clinical reference measures. The method accomplished a mean difference for MAPSE estimates of (-0.16±1.06) mm. Thus, the results did not show significant systematic errors. The obtained bias and variance of the method were comparable to inter-observer variability of clinically obtained MAPSE measures on 2D TTE echocardiography. The novel pipeline proposed in this study has the potential to enhance cardiac monitoring in perioperative- and intensive care settings.
Collapse
|
8
|
Hands-free continuous carotid Doppler ultrasound for detection of the pulse during cardiac arrest in a porcine model. Resusc Plus 2023; 15:100412. [PMID: 37448689 PMCID: PMC10336194 DOI: 10.1016/j.resplu.2023.100412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 05/24/2023] [Accepted: 06/04/2023] [Indexed: 07/15/2023] Open
Abstract
Background/Purpose Pulse palpation is an unreliable method for diagnosing cardiac arrest. To address this limitation, continuous hemodynamic monitoring may be a viable solution. Therefore, we developed a novel, hands-free Doppler system, RescueDoppler, to detect the pulse continuously in the carotid artery. Methods In twelve pigs, we evaluated RescueDoppleŕs potential to measure blood flow velocity in three situations where pulse palpation of the carotid artery was insufficient: (1) systolic blood pressure below 60 mmHg, (2) ventricular fibrillation (VF) and (3) pulseless electrical activity (PEA). (1) Low blood pressure was induced using a Fogarty balloon catheter to occlude the inferior vena cava. (2) An implantable cardioverter-defibrillator induced VF. (3) Myocardial infarction after microembolization of the left coronary artery caused True-PEA. Invasive blood pressure was measured in the contralateral carotid artery. Time-averaged blood flow velocity (TAV) in the carotid artery was related to mean arterial pressure (MAP) in a linear mixed model. Results RescueDoppler identified pulsatile blood flow in 41/41 events with systolic blood pressure below 60 mmHg, with lowest blood pressure of 19 mmHg. In addition the absence of spontaneous circulation was identified in 21/21 VF events and true PEA in 2/2 events. The intraclass correlation coefficient within animals for TAV and MAP was 0.94 (95% CI. 0.85-0.98). Conclusions In a porcine model, RescueDoppler reliably identified pulsative blood flow with blood pressures below 60 mmHg. During VF and PEA, circulatory arrest was rapidly and accurately demonstrated. RescueDoppler could potentially replace unreliable pulse palpation during cardiac arrest and cardiopulmonary resuscitation.
Collapse
|
9
|
Continuous monitoring of cerebral blood flow during general anaesthesia in infants. BJA OPEN 2023; 6:100144. [PMID: 37588175 PMCID: PMC10430850 DOI: 10.1016/j.bjao.2023.100144] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 04/03/2023] [Accepted: 04/22/2023] [Indexed: 08/18/2023]
Abstract
Background General anaesthesia is associated with neurocognitive deficits in infants after noncardiac surgery. Disturbances in cerebral perfusion as a result of systemic hypotension and impaired autoregulation may be a potential cause. Our aim was to study cerebral blood flow (CBF) velocity continuously during general anaesthesia in infants undergoing noncardiac surgery and compare variations in CBF velocity with simultaneously measured near-infrared spectroscopy (NIRS), blood pressure, and heart rate. Methods NeoDoppler, a recently developed ultrasound system, was used to monitor CBF velocity via the anterior fontanelle during induction and maintenance of general anaesthesia until the start of surgery, and during recovery. NIRS, blood pressure, and heart rate were monitored simultaneously and synchronised with the NeoDoppler measurements. Results Thirty infants, with a median postmenstrual age at surgery of 37.6 weeks (range 28.6-60.0) were included. Compared with baseline, the trend curves showed a decrease in CBF velocity during induction and maintenance of anaesthesia and returned to baseline values during recovery. End-diastolic velocity decreased in all infants during anaesthesia, on average by 59%, whereas peak systolic- and time-averaged velocities decreased by 26% and 45%, respectively. In comparison, the reduction in mean arterial pressure was only 20%. NIRS values were high and remained stable. When adjusting for mean arterial pressure, the significant decrease in end-diastolic velocity persisted, whereas there was only a small reduction in peak systolic velocity. Conclusions Continuous monitoring of CBF velocity using NeoDoppler during anaesthesia is feasible and may provide valuable information about cerebral perfusion contributing to a more targeted haemodynamic management in anaesthetised infants.
Collapse
|
10
|
Automated tissue Doppler imaging for identification of occluded coronary artery in patients with suspected non-ST-elevation myocardial infarction. Int J Cardiovasc Imaging 2023; 39:757-766. [PMID: 36715881 PMCID: PMC10104945 DOI: 10.1007/s10554-022-02786-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 12/24/2022] [Indexed: 01/31/2023]
Abstract
PURPOSE Identification of regional dysfunction is important for early risk stratification in patients with suspected non-ST-elevation myocardial infarction (NSTEMI). Strain echocardiography enables quantification of segmental myocardial deformation. However, the clinical use is hampered by time-consuming manual measurements. We aimed to evaluate whether an in-house developed software for automated analysis of segmental myocardial deformation based on tissue Doppler imaging (TDI) could predict coronary occlusion in patients with suspected NSTEMI. METHODS Eighty-four patients with suspected NSTEMI were included in the analysis. Echocardiography was performed at admission. Strain, strain rate and post-systolic shortening index (PSI) were analyzed by the automated TDI-based tool and the ability to predict coronary occlusion was assessed. For comparison, strain measurements were performed both by manual TDI-based analyses and by semi-automatic speckle tracking echocardiography (STE). All patients underwent coronary angiography. RESULTS Seventeen patients had an acute coronary occlusion. Global strain and PSI by STE were able to differentiate occluded from non-occluded culprit lesions (respectively - 15.0% vs. -17.1%, and 8.1% vs. 5.1%, both p-values < 0.05) and identify patients with an acute coronary occlusion (AUC 0.66 for both strain and PSI). Measurements of strain, strain rate and PSI based on TDI were not significantly different between occluded and non-occluded territories. CONCLUSION Automated measurements of myocardial deformation based on TDI were not able to identify acute coronary occlusion in patients with suspected NSTEMI. However, this study confirms the potential of strain by STE for early risk stratification in patients with chest pain.
Collapse
|
11
|
RIB induced reactions: Studying astrophysical reactions with low-energy RI beam at CRIB. EPJ WEB OF CONFERENCES 2023. [DOI: 10.1051/epjconf/202327501015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Astrophysical reactions involving radioactive isotopes (RI) often play an important role in high-temperature stellar environments. The experimental studies on the reaction rates for those are still limited mainly due to the technical difficulties in producing high-quality RI beams. A direct measurement of those reactions would be still challenging in many cases, however, we can make a reliable evaluation of the reaction rates by an indirect method or by studying the resonance prorerties. Here we ntroduce recent examples of experimental studies on such RI-involving astrophysical reactions, performed at Center for Nuclear Study, the University of Tokyo, using the low-energy RI beam separator CRIB. One is for the neutron-induced destruction reactions of 7Be in the Big-Bang nucleosynthesis, and the other is the study on the 22Mg(α, p) reaction relevant in X-ray bursts, which was performed with the resonant scattering method from the inverse reaction channel.
Collapse
|
12
|
Experimental studies on astrophysical reactions at the low-energy RI beam separator CRIB. EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202226003003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Experimental studies on astrophysical reactions involving radioactive isotopes (RI) often accompany technical challenges. Studies on such nuclear reactions have been conducted at the low-energy RI beam separator CRIB, operated by Center for Nuclear Study, the University of Tokyo. We discuss two cases of astrophysical reaction studies at CRIB; one is for the 7Be+n reactions which may affect the primordial 7Li abundance in the Big-Bang nucleosynthesis, and the other is for the 22Mg(α, p) reaction relevantin X-raybursts.
Collapse
|
13
|
The effect of hutch compass direction on primary heat stress responses in dairy calves in a continental region. Anim Welf 2021. [DOI: 10.7120/09627286.30.3.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Heat stress reduction in hutch-reared dairy calves is overlooked on most dairy farms. We hypothesised that during summer, the microclimate within hutches is directly affected by compass direction as a result of differences in exposure to solar radiation. On a bright, midAugust day a
number of behavioural and physiological heat stress response measures (respiratory rate, body posture, being in the shade or sun) were recorded in 20-min intervals from 0720–1900h on calves housed in hutches with entrances facing all four points of the compass. In conjunction with this,
dry bulb (ambient) and black globe temperatures, and wind speed were recorded both inside the plastic hutches and at one sunny site at the exterior. Data were compared in terms of distinct periods of the day (0720–1100, 1120– 1500, 1520–1900h). Dry bulb temperatures were
higher inside hutches compared to outside while for black globe temperatures the opposite was true. Daily average temperatures and respiratory rates did not differ between hutches facing different compass points. In the morning and afternoon, hutch temperature and calf respiratory rate differed
relative to compass point. Calves in east- and northfacing hutches were seen more in the shade than those in south- and west-facing ones. Our conclusion was that in a continental region having hutch entrances face towards the east or north confers some advantages in mitigating severe solar
heat load in summer.
Collapse
|
14
|
Preliminary Design of the Fusion Power Shutdown System Unit for ITER. FUSION SCIENCE AND TECHNOLOGY 2021. [DOI: 10.1080/15361055.2021.1874764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
15
|
Feasibility and Reliability of Automatic Quantitative Analyses of Mitral Annular Plane Systolic Excursion by Handheld Ultrasound Devices: A Pilot Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:341-350. [PMID: 32710577 DOI: 10.1002/jum.15408] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 06/04/2020] [Accepted: 06/24/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Handheld ultrasound devices (HUDs) have previously been limited to grayscale imaging without options for left ventricle (LV) quantification. We aimed to study the feasibility and reliability of automatic measurements of mitral annular plane systolic excursion (MAPSE) by HUDs. METHODS An algorithm that automatically measured MAPSE from live grayscale recordings was implemented in a HUD. Twenty patients at a university hospital were examined by either a cardiologist or a sonographer. Standard echocardiography using a high-end scanner was performed. The apical 4-chamber view was recorded 4 times by both echocardiography and the HUD. MAPSE was measured by M-mode and color tissue Doppler (cTD) during echocardiography and automatically by the HUD. RESULTS The automatic method underestimated mean MAPSE ± SD versus M-mode (9.6 ± 2.2 versus 10.9 ± 2.6 mm; difference, 1.2 ± 1.4 mm, P < .005). The difference between the automatic and cTD measurements was not significant (0.8 ± 1.8 mm; P = .073). The intraclass correlation coefficients (ICCs) between automatic and M-mode measurements was 0.85, and 0.81 for cTD measurements. There was good agreement between the methods, and the intra- and inter-rater ICCs were excellent for all methods (≥0.86). CONCLUSIONS In this novel study evaluating automatic quantification of LV longitudinal function by HUD, we showed the high feasibility and reliability of the method. Compared to M-mode imaging, the automatic method underestimated MAPSE by 8% to 10%, but the difference with cTD imaging was nonsignificant. We conclude that this study's method for automatic quantitative assessment of LV function can be integrated in HUDs.
Collapse
|
16
|
Structural Design for ITER Gas Injection System Gas Fueling Gas Valve Box. FUSION SCIENCE AND TECHNOLOGY 2020. [DOI: 10.1080/15361055.2020.1817702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
17
|
No evidence of cardiac stunning or decoupling immediately after cardiopulmonary bypass for elective coronary surgery. Acta Anaesthesiol Scand 2020; 64:1128-1135. [PMID: 32407541 DOI: 10.1111/aas.13621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 05/04/2020] [Accepted: 05/06/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND There is significant uncertainty regarding the timing of onset of cardiovascular stunning after cardiac surgery. Cardiovascular stunning is affecting both contractility (Ees) and arterial load. Arterial load may be represented by arterial elastance (Ea) and participates in ventriculo-arterial coupling through the Ea/Ees ratio, giving information on efficiency and performance. An alternative approach to ventriculo-arterial interaction is oscillatory power fraction (OPF). The aim of this study was to investigate the immediate beat-to-beat effects of on-pump coronary artery bypass graft (CABG) surgery on contractility, cardiac power parameters, arterial load and ventriculo-arterial coupling as well as classical haemodynamic parameters. METHODS We included 41 patients scheduled for fast-track CABG surgery. Measurements were taken before and after cardiopulmonary bypass. A flow and pressure curve were recorded from transoesophageal pulsed wave Doppler and a radial artery catheter, respectively. This enabled the calculation of stroke work, total cardiac energy delivery, OPF and Ea/Ees ratio. Routine haemodynamic monitoring provided the classical haemodynamic parameters. RESULTS Immediately after cardiopulmonary bypass there was no firm evidence for alterations in contractility, stroke work, stroke volume or arterial elastance. Ea/Ees ratio and OPF remained unchanged. CONCLUSIONS There was no evidence for clinically relevant cardiac stunning or altered arterial load immediately after cardiopulmonary bypass for CABG surgery. The unchanged Ea/Ees ratio and OPF are indicating unchanged cardiac efficiency before and after cardiopulmonary bypass. This indicates that in elective CABG patients cardiovascular stunning is perhaps a phenomenon of inflammation and not immediate ischaemia-reperfusion injury or mechanical handling.
Collapse
|
18
|
Recovery of Flexible Polyurethane Foam Waste for Efficient Reuse in Industrial Formulations. Polymers (Basel) 2020; 12:polym12071533. [PMID: 32664336 PMCID: PMC7407941 DOI: 10.3390/polym12071533] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 07/04/2020] [Accepted: 07/06/2020] [Indexed: 11/19/2022] Open
Abstract
Ester polyurethane (PU) foam waste was reacted at atmospheric pressure in an autoclave and using microwaves with diethylene glycol (DEG) at different PU/DEG ratios in the presence of diethanolamine as a catalyst to find the glycolysis conditions that allow for the improved recovery of the PU foam waste and enable the recycling of the whole glycolysis product in foam formulations suitable for industrial application. The recycled polyol was characterized by dynamic viscosity, hydroxyl number, water content, and density, while thermal stability was assessed using thermogravimetric analysis. In the PU foam formulation, 1% and 5% of the glycolyzed material was reused. The relationship between the reuse level of the recycled polyol and the physical properties of the foam was thoroughly investigated. It was observed that both hardness and air flow decreased with increasing recycled polyol content, particularly for the polyester type foam, while tensile strength and compression strength increased. Depending on the amount of recycled polyol and catalyst used, polyether-based foams could be obtained with a low air permeability, needed in special applications as sealed foams, or with higher air permeability desirable for comfort PU foams. The results open the way for further optimization studies of industrial polyurethane foam formulations using a glycolysis process without any separation stage.
Collapse
|
19
|
[Use of synthetic slings and mesh implants in the treatment of female stress urinary incontinence and prolapse : Statement of the Working Group on Urological Functional Diagnostics and Female Urology of the Academy of the German Society of Urology]. Urologe A 2020; 59:65-71. [PMID: 31741004 DOI: 10.1007/s00120-019-01074-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Due to a safety alert issued by the US Food and Drug Administration (FDA) in 2011 for transvaginal mesh implants to treat female prolapse as a result of numerous reports of complications such as infection, chronic pain, dyspareunia, vaginal erosion, shrinkage and erosion into other organs nearly all industrial products have been withdrawn from the market in the meantime. The United Kingdom, Australia, and New Zealand extended warnings and prohibitions even on the implantation of midurethral slings (TVT, TOT). In view of these current international controversies regarding the use of implanted materials for the treatment of stress incontinence and prolapse and the lack of clear guidelines for the use of biomaterials, the opinion of the Working Group on Urological Functional Diagnostics and Female Urology should provide clarity. The Opinion is based on the SCENIHR Report of the "European Commission's Scientific Committee on Emerging and Newly Identified Health Risks", the "Consensus Statement of the European Urology Association and the European Urogynaecological Association on the Use of Implanted Materials for Treating Pelvic Organ Prolapse and Stress Urinary Incontinence" and in compliance with relevant EAU and national guidelines and the opinion of the Association for Urogynaecology and Plastic Pelvic Floor Reconstruction (AGUB eV). In addition, recommendations are given for the future handling of implants of slings and meshes for the treatment of stress incontinence and prolapse from a urologic viewpoint.
Collapse
|
20
|
Morphological transformations during Fischer-Tropsch synthesis on a titania-supported cobalt catalyst. Catal Today 2019. [DOI: 10.1016/j.cattod.2018.05.021] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
Daclatasvir and Sofosbuvir With or Without Ribavirin in Liver Transplant Recipients: A Single-Center Real-World Study. Transplant Proc 2018; 50:769-771. [PMID: 29661434 DOI: 10.1016/j.transproceed.2018.02.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND Treatment with direct-acting antiviral drugs in interferon-free regimens is currently recommended for viral hepatitis C recurrence after liver transplantation. There are limited data regarding its results in this population, and no optimal treatment scheme has yet been singled out. METHODS We report our real-world results in liver transplant (LT) recipients. All patients were hepatitis C virus (HCV) monoinfected and completed a 12-week treatment course, followed 12 weeks later by HCV polymerase chain reaction testing with 12 IU/mL sensibility. Liver fibrosis was graded with the use of biopsies taken <12 months before treatment and stratified as early (0-1) or moderate to advanced (2-4) according to the Metavir score. RESULTS Median postoperative time was 5.2 years. Genotype 3 was found in 66.7% of the sample. The following regimens were prescribed: daclatasvir-sofosbuvir with (n = 11) or without (n = 28) ribavirin. Genotypes 1 and 3 were evenly distributed between the regimens. Sustained virologic response (SVR) was obtained in 24 out of 28 patients (85.7%) who received daclatasvir-sofosbuvir and in all patients (100%) who received daclatasvir-sofosbuvir-ribavirin (global SVR 89.7%). All patients that failed treatment had genotype 3 HCV. Fibrosis was evaluated in 79.5% of the sample: 48.4% had early and 51.6% had moderate to advanced fibrosis, for which ribavirin was more commonly prescribed (P = .001). CONCLUSIONS The SVR rate in our LT recipients was similar to that previously reported in the literature. The addition of ribavirin to DAA treatment appears to be justified in this population.
Collapse
|
22
|
P5618The feasibility, accuracy and reliability of fully automatic analyses of left ventricular systolic longitudinal function by pocket-size imaging device. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy566.p5618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
Abstract
INTRODUCTION Post-transplantation portal hypertension has severe complications, such as esophageal varix bleeding, therapy refractory ascites, extreme splenomegaly, and graft dysfunction. The aim of our study was to analyze the effectiveness of the therapeutic strategies and how to visualize the procedure. METHODS A retrospective study involving liver transplantation patients from the Semmelweis University Department of Transplantation and Surgery was performed between 2005 and 2015. The prevalence, etiology, and leading complications of the condition were determined. The applied interventions' effects on the patients' ascites volume, splenic volume, and the occurrence of variceal bleeding were determined. Mean portal blood flow velocity and congestion index values were calculated using Doppler ultrasonography. RESULTS The prevalence of post-transplantation portal hypertension requiring intervention was 2.8%. The most common etiology of the disease was portal anastomotic stenosis. The most common complications were esophageal varix bleeding and therapy refractory ascites. The patients' ascites volume decreased significantly (2923.3 ± 1893.2 mL vs. 423.3 ± 634.3 mL; P < .05), their splenic volume decreased markedly. After the interventions, only one case of recurrent variceal bleeding was reported. The calculated Doppler parameters were altered in the opposite direction in cases of pre-hepatic versus intra- or post-hepatic portal hypertension. After the interventions, these parameters shifted towards the physiologic ranges. CONCLUSION The interventions performed in our clinic were effective in most cases. The patients' ascites volume, splenic volume, and the prevalence of variceal bleeding decreased after the treatment. Doppler ultrasonography has proved to be a valuable imaging modality in the diagnosis and the follow-up of post-transplantation portal hypertension.
Collapse
|
24
|
D-Meson Azimuthal Anisotropy in Midcentral Pb-Pb Collisions at sqrt[s]_{NN}=5.02 TeV. PHYSICAL REVIEW LETTERS 2018; 120:102301. [PMID: 29570314 DOI: 10.1103/physrevlett.120.102301] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2017] [Revised: 11/16/2017] [Indexed: 06/08/2023]
Abstract
The azimuthal anisotropy coefficient v_{2} of prompt D^{0}, D^{+}, D^{*+}, and D_{s}^{+} mesons was measured in midcentral (30%-50% centrality class) Pb-Pb collisions at a center-of-mass energy per nucleon pair sqrt[s_{NN}]=5.02 TeV, with the ALICE detector at the LHC. The D mesons were reconstructed via their hadronic decays at midrapidity, |y|<0.8, in the transverse momentum interval 1<p_{T}<24 GeV/c. The measured D-meson v_{2} has similar values as that of charged pions. The D_{s}^{+} v_{2}, measured for the first time, is found to be compatible with that of nonstrange D mesons. The measurements are compared with theoretical calculations of charm-quark transport in a hydrodynamically expanding medium and have the potential to constrain medium parameters.
Collapse
|
25
|
J/ψ Elliptic Flow in Pb-Pb Collisions at sqrt[s_{NN}]=5.02 TeV. PHYSICAL REVIEW LETTERS 2017; 119:242301. [PMID: 29286736 DOI: 10.1103/physrevlett.119.242301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Indexed: 06/07/2023]
Abstract
We report a precise measurement of the J/ψ elliptic flow in Pb-Pb collisions at sqrt[s_{NN}]=5.02 TeV with the ALICE detector at the LHC. The J/ψ mesons are reconstructed at midrapidity (|y|<0.9) in the dielectron decay channel and at forward rapidity (2.5<y<4.0) in the dimuon channel, both down to zero transverse momentum. At forward rapidity, the elliptic flow v_{2} of the J/ψ is studied as a function of the transverse momentum and centrality. A positive v_{2} is observed in the transverse momentum range 2<p_{T}<8 GeV/c in the three centrality classes studied and confirms with higher statistics our earlier results at sqrt[s_{NN}]=2.76 TeV in semicentral collisions. At midrapidity, the J/ψ v_{2} is investigated as a function of the transverse momentum in semicentral collisions and found to be in agreement with the measurements at forward rapidity. These results are compared to transport model calculations. The comparison supports the idea that at low p_{T} the elliptic flow of the J/ψ originates from the thermalization of charm quarks in the deconfined medium but suggests that additional mechanisms might be missing in the models.
Collapse
|
26
|
Anomalous Evolution of the Near-Side Jet Peak Shape in Pb-Pb Collisions at sqrt[s_{NN}]=2.76 TeV. PHYSICAL REVIEW LETTERS 2017; 119:102301. [PMID: 28949169 DOI: 10.1103/physrevlett.119.102301] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Indexed: 06/07/2023]
Abstract
The measurement of two-particle angular correlations is a powerful tool to study jet quenching in a p_{T} region inaccessible by direct jet identification. In these measurements pseudorapidity (Δη) and azimuthal (Δφ) differences are used to extract the shape of the near-side peak formed by particles associated with a higher p_{T} trigger particle (1<p_{T,trig}<8 GeV/c). A combined fit of the near-side peak and long-range correlations is applied to the data allowing the extraction of the centrality evolution of the peak shape in Pb-Pb collisions at sqrt[s_{NN}]=2.76 TeV. A significant broadening of the peak in the Δη direction at low p_{T} is found from peripheral to central collisions, which vanishes above 4 GeV/c, while in the Δφ direction the peak is almost independent of centrality. For the 10% most central collisions and 1<p_{T,assoc}<2 GeV/c, 1<p_{T,trig}<3 GeV/c a novel feature is observed: a depletion develops around the center of the peak. The results are compared to pp collisions at the same center of mass energy and ampt model simulations. The comparison to the investigated models suggests that the broadening and the development of the depletion is connected to the strength of radial and longitudinal flow.
Collapse
|
27
|
Energy dependence of forward-rapidity [Formula: see text] and [Formula: see text] production in pp collisions at the LHC. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2017; 77:392. [PMID: 28775665 PMCID: PMC5512511 DOI: 10.1140/epjc/s10052-017-4940-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Accepted: 05/24/2017] [Indexed: 06/07/2023]
Abstract
We present results on transverse momentum ([Formula: see text]) and rapidity ([Formula: see text]) differential production cross sections, mean transverse momentum and mean transverse momentum square of inclusive [Formula: see text] and [Formula: see text] at forward rapidity ([Formula: see text]) as well as [Formula: see text]-to-[Formula: see text] cross section ratios. These quantities are measured in pp collisions at center of mass energies [Formula: see text] and 13 TeV with the ALICE detector. Both charmonium states are reconstructed in the dimuon decay channel, using the muon spectrometer. A comprehensive comparison to inclusive charmonium cross sections measured at [Formula: see text], 7 and 8 TeV is performed. A comparison to non-relativistic quantum chromodynamics and fixed-order next-to-leading logarithm calculations, which describe prompt and non-prompt charmonium production respectively, is also presented. A good description of the data is obtained over the full [Formula: see text] range, provided that both contributions are summed. In particular, it is found that for [Formula: see text] GeV/c the non-prompt contribution reaches up to 50% of the total charmonium yield.
Collapse
|
28
|
Production of Σ(1385)± and Ξ(1530)0 in p-Pb collisions at sNN=5.02 TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2017; 77:389. [PMID: 29430210 PMCID: PMC5797483 DOI: 10.1140/epjc/s10052-017-4943-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 05/24/2017] [Indexed: 06/08/2023]
Abstract
The transverse momentum distributions of the strange and double-strange hyperon resonances (Σ ( 1385 ) ± , Ξ ( 1530 ) 0 ) produced in p-Pb collisions at s NN = 5.02 TeV were measured in the rapidity range - 0.5 < y CMS < 0 for event classes corresponding to different charged-particle multiplicity densities, ⟨ dN ch /dη lab ⟩ . The mean transverse momentum values are presented as a function of ⟨ dN ch /dη lab ⟩ , as well as a function of the particle masses and compared with previous results on hyperon production. The integrated yield ratios of excited to ground-state hyperons are constant as a function of ⟨ dN ch /dη lab ⟩ . The equivalent ratios to pions exhibit an increase with ⟨ dN ch /dη lab ⟩ , depending on their strangeness content.
Collapse
|
29
|
Production of [Formula: see text] and [Formula: see text] mesons up to high transverse momentum in pp collisions at 2.76 TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2017; 77:339. [PMID: 28943788 PMCID: PMC5586361 DOI: 10.1140/epjc/s10052-017-4890-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Accepted: 05/05/2017] [Indexed: 06/07/2023]
Abstract
The invariant differential cross sections for inclusive [Formula: see text] and [Formula: see text] mesons at midrapidity were measured in pp collisions at [Formula: see text] TeV for transverse momenta [Formula: see text] GeV/c and [Formula: see text] GeV/c, respectively, using the ALICE detector. This large range in [Formula: see text] was achieved by combining various analysis techniques and different triggers involving the electromagnetic calorimeter (EMCal). In particular, a new single-cluster, shower-shape based method was developed for the identification of high-[Formula: see text] neutral pions, which exploits that the showers originating from their decay photons overlap in the EMCal. Above 4 GeV/[Formula: see text], the measured cross sections are found to exhibit a similar power-law behavior with an exponent of about 6.3. Next-to-leading-order perturbative QCD calculations differ from the measured cross sections by about 30% for the [Formula: see text], and between 30-50% for the [Formula: see text] meson, while generator-level simulations with PYTHIA 8.2 describe the data to better than 10-30%, except at [Formula: see text] GeV/[Formula: see text]. The new data can therefore be used to further improve the theoretical description of [Formula: see text] and [Formula: see text] meson production.
Collapse
|
30
|
Flow Dominance and Factorization of Transverse Momentum Correlations in Pb-Pb Collisions at the LHC. PHYSICAL REVIEW LETTERS 2017; 118:162302. [PMID: 28474923 DOI: 10.1103/physrevlett.118.162302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Indexed: 06/07/2023]
Abstract
We present the first measurement of the two-particle transverse momentum differential correlation function, P_{2}≡⟨Δp_{T}Δp_{T}⟩/⟨p_{T}⟩^{2}, in Pb-Pb collisions at sqrt[s_{NN}]=2.76 TeV. Results for P_{2} are reported as a function of the relative pseudorapidity (Δη) and azimuthal angle (Δφ) between two particles for different collision centralities. The Δϕ dependence is found to be largely independent of Δη for |Δη|≥0.9. In the 5% most central Pb-Pb collisions, the two-particle transverse momentum correlation function exhibits a clear double-hump structure around Δφ=π (i.e., on the away side), which is not observed in number correlations in the same centrality range, and thus provides an indication of the dominance of triangular flow in this collision centrality. Fourier decompositions of P_{2}, studied as a function of the collision centrality, show that correlations at |Δη|≥0.9 can be well reproduced by a flow ansatz based on the notion that measured transverse momentum correlations are strictly determined by the collective motion of the system.
Collapse
|
31
|
Measurement of azimuthal correlations of D mesons with charged particles in pp collisions at [Formula: see text] TeV and p-Pb collisions at [Formula: see text] TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2017; 77:245. [PMID: 28515667 PMCID: PMC5409029 DOI: 10.1140/epjc/s10052-017-4779-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 03/21/2017] [Indexed: 06/07/2023]
Abstract
The azimuthal correlations of D mesons with charged particles were measured with the ALICE apparatus in pp collisions at [Formula: see text] and p-Pb collisions at [Formula: see text] at the Large Hadron Collider. [Formula: see text], [Formula: see text], and [Formula: see text] mesons and their charge conjugates with transverse momentum [Formula: see text] and rapidity in the nucleon-nucleon centre-of-mass system [Formula: see text] (pp collisions) and [Formula: see text] (p-Pb collisions) were correlated to charged particles with [Formula: see text]. The yield of charged particles in the correlation peak induced by the jet containing the D meson and the peak width are compatible within uncertainties in the two collision systems. The data are described within uncertainties by Monte-Carlo simulations based on PYTHIA, POWHEG, and EPOS 3 event generators.
Collapse
|
32
|
Disruption Mitigation System Developments and Design for ITER. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.13182/fst14-926] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
33
|
Automatic Detection and Measurement of Fetal Biparietal Diameter and Femur Length —Feasibility on a Portable Ultrasound Device. ACTA ACUST UNITED AC 2017. [DOI: 10.4236/ojog.2017.73035] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
34
|
Biodegradable airway stents in infants - Potential life-threatening pitfalls. Int J Pediatr Otorhinolaryngol 2016; 91:86-89. [PMID: 27863648 DOI: 10.1016/j.ijporl.2016.10.013] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 10/10/2016] [Accepted: 10/12/2016] [Indexed: 10/20/2022]
Abstract
OBJECTIVE The solution of severe tracheobronchial obstructions in early childhood means a great challenge. Biodegradable stents were intended to be a minimally invasive temporary solution which may decrease the number of interventions and limit the possible complications of stenting procedures. However, our first experiences have brought out a new, - especially in childhood - potentially life-threatening complication of this concept. METHODS Five SX-ELLA biodegradable polydioxanone stents was applied in three patients because of severe tracheobronchial obstruction: congenital tracheomalacia (7 day-old), acquired tracheomalacia (10 month-old), and congenital trachea-bronchomalacia (10 month-old). RESULTS The breathing of all children improved right after the procedure. We observed degradation of the stent from the 5th postoperative week which resulted in large intraluminar fragments causing significant airway obstruction: one patient died of severe pneumonia, the other baby required urgent bronchoscopy to remove the obstructing 'foreign body' from the trachea. In the third case repeated stent placements successfully maintained the tracheal lumen. CONCLUSIONS Polydioxanone stents may offer an alternative to metallic or silastic stents for collapse or external compression of the trachea in children; however, large decaying fragments mean a potential risk especially in the small size pediatric airway. The fragmentation of the stent, which generally starts in the 4-6 postoperative weeks, may create large sharp pieces. These may be anchored to the mucosa and covered by crust leading to obstruction. As repeated interventions are required, we do not consider the application of biodegradable stents unambiguously advantageous.
Collapse
|
35
|
Adaptive Spectral Envelope Estimation for Doppler Ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1825-1838. [PMID: 27824563 DOI: 10.1109/tuffc.2016.2587381] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this paper for maximum velocity point detection has been developed by modifying an existing method-signal noise slope intersection, incorporating in it steps from an altered version of another method called geometric method. Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained postdetection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings, as well as in vivo recordings from uterine, umbilical, carotid, and subclavian arteries. The results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles, and SNR levels. Standard deviation in the envelope is low-less than 2% in the case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow, and also less than 2% in the case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of pulsatility index estimation in uterine and umbilical arteries.
Collapse
|
36
|
Correlated Event-by-Event Fluctuations of Flow Harmonics in Pb-Pb Collisions at sqrt[s_{NN}]=2.76 TeV. PHYSICAL REVIEW LETTERS 2016; 117:182301. [PMID: 27835023 DOI: 10.1103/physrevlett.117.182301] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Indexed: 06/06/2023]
Abstract
We report the measurements of correlations between event-by-event fluctuations of amplitudes of anisotropic flow harmonics in nucleus-nucleus collisions, obtained for the first time using a new analysis method based on multiparticle cumulants in mixed harmonics. This novel method is robust against systematic biases originating from nonflow effects and by construction any dependence on symmetry planes is eliminated. We demonstrate that correlations of flow harmonics exhibit a better sensitivity to medium properties than the individual flow harmonics. The new measurements are performed in Pb-Pb collisions at the center-of-mass energy per nucleon pair of sqrt[s_{NN}]=2.76 TeV by the ALICE experiment at the Large Hadron Collider. The centrality dependence of correlation between event-by-event fluctuations of the elliptic v_{2} and quadrangular v_{4} flow harmonics, as well as of anticorrelation between v_{2} and triangular v_{3} flow harmonics are presented. The results cover two different regimes of the initial state configurations: geometry dominated (in midcentral collisions) and fluctuation dominated (in the most central collisions). Comparisons are made to predictions from Monte Carlo Glauber, viscous hydrodynamics, ampt, and hijing models. Together with the existing measurements of the individual flow harmonics the presented results provide further constraints on the initial conditions and the transport properties of the system produced in heavy-ion collisions.
Collapse
|
37
|
Centrality Dependence of the Charged-Particle Multiplicity Density at Midrapidity in Pb-Pb Collisions at sqrt[s_{NN}]=5.02 TeV. PHYSICAL REVIEW LETTERS 2016; 116:222302. [PMID: 27314715 DOI: 10.1103/physrevlett.116.222302] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Indexed: 06/06/2023]
Abstract
The pseudorapidity density of charged particles, dN_{ch}/dη, at midrapidity in Pb-Pb collisions has been measured at a center-of-mass energy per nucleon pair of sqrt[s_{NN}]=5.02 TeV. For the 5% most central collisions, we measure a value of 1943±54. The rise in dN_{ch}/dη as a function of sqrt[s_{NN}] is steeper than that observed in proton-proton collisions and follows the trend established by measurements at lower energy. The increase of dN_{ch}/dη as a function of the average number of participant nucleons, ⟨N_{part}⟩, calculated in a Glauber model, is compared with the previous measurement at sqrt[s_{NN}]=2.76 TeV. A constant factor of about 1.2 describes the increase in dN_{ch}/dη from sqrt[s_{NN}]=2.76 to 5.02 TeV for all centrality classes, within the measured range of 0%-80% centrality. The results are also compared to models based on different mechanisms for particle production in nuclear collisions.
Collapse
|
38
|
Measurement of an Excess in the Yield of J/ψ at Very Low p_{T} in Pb-Pb Collisions at sqrt[s]_{NN}=2.76 TeV. PHYSICAL REVIEW LETTERS 2016; 116:222301. [PMID: 27314714 DOI: 10.1103/physrevlett.116.222301] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Indexed: 06/06/2023]
Abstract
We report on the first measurement of an excess in the yield of J/ψ at very low transverse momentum (p_{T}<0.3 GeV/c) in peripheral hadronic Pb-Pb collisions at sqrt[s_{NN}]=2.76 TeV, performed by ALICE at the CERN LHC. Remarkably, the measured nuclear modification factor of J/ψ in the rapidity range 2.5<y<4 reaches about 7 (2) in the p_{T} range 0-0.3 GeV/c in the 70%-90% (50%-70%) centrality class. The J/ψ production cross section associated with the observed excess is obtained under the hypothesis that coherent photoproduction of J/ψ is the underlying physics mechanism. If confirmed, the observation of J/ψ coherent photoproduction in Pb-Pb collisions at impact parameters smaller than twice the nuclear radius opens new theoretical and experimental challenges and opportunities. In particular, coherent photoproduction accompanying hadronic collisions may provide insight into the dynamics of photoproduction and nuclear reactions, as well as become a novel probe of the quark-gluon plasma.
Collapse
|
39
|
Centrality dependence of charged jet production in p-Pb collisions at [Formula: see text] = 5.02 TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2016; 76:271. [PMID: 28280431 PMCID: PMC5321247 DOI: 10.1140/epjc/s10052-016-4107-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Accepted: 04/24/2016] [Indexed: 06/05/2023]
Abstract
Measurements of charged jet production as a function of centrality are presented for p-Pb collisions recorded at [Formula: see text] TeV with the ALICE detector. Centrality classes are determined via the energy deposit in neutron calorimeters at zero degree, close to the beam direction, to minimise dynamical biases of the selection. The corresponding number of participants or binary nucleon-nucleon collisions is determined based on the particle production in the Pb-going rapidity region. Jets have been reconstructed in the central rapidity region from charged particles with the anti-[Formula: see text] algorithm for resolution parameters [Formula: see text] and [Formula: see text] in the transverse momentum range 20 to 120 GeV/c. The reconstructed jet momentum and yields have been corrected for detector effects and underlying-event background. In the five centrality bins considered, the charged jet production in p-Pb collisions is consistent with the production expected from binary scaling from pp collisions. The ratio of jet yields reconstructed with the two different resolution parameters is also independent of the centrality selection, demonstrating the absence of major modifications of the radial jet structure in the reported centrality classes.
Collapse
|
40
|
Production of K[Formula: see text](892)[Formula: see text] and [Formula: see text](1020) in p-Pb collisions at [Formula: see text] = 5.02 TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2016; 76:245. [PMID: 27217821 PMCID: PMC4861205 DOI: 10.1140/epjc/s10052-016-4088-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Accepted: 04/14/2016] [Indexed: 06/05/2023]
Abstract
The production of K[Formula: see text](892)[Formula: see text] and [Formula: see text](1020) mesons has been measured in p-Pb collisions at [Formula: see text][Formula: see text] 5.02 TeV. K[Formula: see text] and [Formula: see text] are reconstructed via their decay into charged hadrons with the ALICE detector in the rapidity range [Formula: see text]. The transverse momentum spectra, measured as a function of the multiplicity, have a p[Formula: see text] range from 0 to 15 GeV/c for K[Formula: see text] and from 0.3 to 21 GeV/c for [Formula: see text]. Integrated yields, mean transverse momenta and particle ratios are reported and compared with results in pp collisions at [Formula: see text][Formula: see text] 7 TeV and Pb-Pb collisions at [Formula: see text][Formula: see text] 2.76 TeV. In Pb-Pb and p-Pb collisions, K[Formula: see text] and [Formula: see text] probe the hadronic phase of the system and contribute to the study of particle formation mechanisms by comparison with other identified hadrons. For this purpose, the mean transverse momenta and the differential proton-to-[Formula: see text] ratio are discussed as a function of the multiplicity of the event. The short-lived K[Formula: see text] is measured to investigate re-scattering effects, believed to be related to the size of the system and to the lifetime of the hadronic phase.
Collapse
|
41
|
Inclusive quarkonium production at forward rapidity in pp collisions at [Formula: see text]TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2016; 76:184. [PMID: 28260969 PMCID: PMC5312164 DOI: 10.1140/epjc/s10052-016-3987-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 02/29/2016] [Indexed: 06/06/2023]
Abstract
We report on the inclusive production cross sections of [Formula: see text], [Formula: see text], [Formula: see text](1S), [Formula: see text](2S) and [Formula: see text](3S), measured at forward rapidity with the ALICE detector in [Formula: see text] collisions at a center-of-mass energy [Formula: see text] TeV. The analysis is based on data collected at the LHC and corresponds to an integrated luminosity of 1.23 pb[Formula: see text]. Quarkonia are reconstructed in the dimuon-decay channel. The differential production cross sections are measured as a function of the transverse momentum [Formula: see text] and rapidity y, over the [Formula: see text] ranges [Formula: see text] GeV/c for [Formula: see text], [Formula: see text] GeV/c for all other resonances, and for [Formula: see text]. The cross sections, integrated over [Formula: see text] and y, and assuming unpolarized quarkonia, are [Formula: see text] [Formula: see text]b, [Formula: see text] [Formula: see text]b, [Formula: see text] nb, [Formula: see text] nb and [Formula: see text] nb, where the first uncertainty is statistical and the second one is systematic. These values agree, within at most [Formula: see text], with measurements performed by the LHCb collaboration in the same rapidity range.
Collapse
|
42
|
Anisotropic Flow of Charged Particles in Pb-Pb Collisions at √[s{NN}]=5.02 TeV. PHYSICAL REVIEW LETTERS 2016; 116:132302. [PMID: 27081971 DOI: 10.1103/physrevlett.116.132302] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Indexed: 06/05/2023]
Abstract
We report the first results of elliptic (v_{2}), triangular (v_{3}), and quadrangular (v_{4}) flow of charged particles in Pb-Pb collisions at a center-of-mass energy per nucleon pair of sqrt[s_{NN}]=5.02 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurements are performed in the central pseudorapidity region |η|<0.8 and for the transverse momentum range 0.2<p_{T}<5 GeV/c. The anisotropic flow is measured using two-particle correlations with a pseudorapidity gap greater than one unit and with the multiparticle cumulant method. Compared to results from Pb-Pb collisions at sqrt[s_{NN}]=2.76 TeV, the anisotropic flow coefficients v_{2}, v_{3}, and v_{4} are found to increase by (3.0±0.6)%, (4.3±1.4)%, and (10.2±3.8)%, respectively, in the centrality range 0%-50%. This increase can be attributed mostly to an increase of the average transverse momentum between the two energies. The measurements are found to be compatible with hydrodynamic model calculations. This comparison provides a unique opportunity to test the validity of the hydrodynamic picture and the power to further discriminate between various possibilities for the temperature dependence of shear viscosity to entropy density ratio of the produced matter in heavy-ion collisions at the highest energies.
Collapse
|
43
|
Multiplicity and transverse momentum evolution of charge-dependent correlations in pp, p-Pb, and Pb-Pb collisions at the LHC. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2016; 76:86. [PMID: 27069415 PMCID: PMC4811057 DOI: 10.1140/epjc/s10052-016-3915-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Accepted: 01/29/2016] [Indexed: 06/05/2023]
Abstract
We report on two-particle charge-dependent correlations in pp, p-Pb, and Pb-Pb collisions as a function of the pseudorapidity and azimuthal angle difference, [Formula: see text] and [Formula: see text] respectively. These correlations are studied using the balance function that probes the charge creation time and the development of collectivity in the produced system. The dependence of the balance function on the event multiplicity as well as on the trigger and associated particle transverse momentum ([Formula: see text]) in pp, p-Pb, and Pb-Pb collisions at [Formula: see text] 7, 5.02, and 2.76 TeV, respectively, are presented. In the low transverse momentum region, for [Formula: see text] GeV/c, the balance function becomes narrower in both [Formula: see text] and [Formula: see text] directions in all three systems for events with higher multiplicity. The experimental findings favor models that either incorporate some collective behavior (e.g. AMPT) or different mechanisms that lead to effects that resemble collective behavior (e.g. PYTHIA8 with color reconnection). For higher values of transverse momenta the balance function becomes even narrower but exhibits no multiplicity dependence, indicating that the observed narrowing with increasing multiplicity at low [Formula: see text] is a feature of bulk particle production.
Collapse
|
44
|
Comparison Between IGL-1 and HTK Preservation Solutions in Deceased Donor Liver Transplantation. Transplant Proc 2016; 47:888-93. [PMID: 26036479 DOI: 10.1016/j.transproceed.2015.03.033] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The effectiveness of liver preservation solutions remains in evidence. Cold ischemia time, steatosis, expanded criterion donors, operational cost, and survival represent important roles in its success. In a prospective cohort study between August 2009 and April 2014, 178 patients were allocated into an Institut Georges Lopez - 1 (IGL-1) solution group (63.5%) or histidine-tryptophan-ketoglutarate (HTK) group (36.5%). There were no differences among recipient's characteristics including age, skin color, gender, Model for End-stage Liver Disease score, acute rejection, cholestasis, and reperfusion syndrome incidences. Also, donors, age average, skin color, donor risk index, time in intensive care unit, hemodynamic variables, infections, and steatosis incidences were similar. The average cold ischemia time was 494 minutes in the IGL-1 group and 489 minutes in the HTK group (P = .77). Alanine aminotransferase and aspartate aminotransferase serum levels on the first postoperative day were 707 and 1185 mg/dL, respectively, with IGL-1 and 1298 and 2291 mg/dL, respectively, with HTK (P = .016) and similar at day 15 (P > .88). The incidence of delayed graft function was 4.5% with IGL-1 and 4.6% with HTK (P = .90). The incidence primary nonfunction was 2.7% with IGL-1 and 3.1% with HTK (P = .71). The incidence of perioperative death was 11.5% with IGL-1 and 13.8% with HTK (P = .94). The survival in 30 months was 86% in IGL-1 group and 82% in HTK group (P = .66). Both preservation solutions are efficient to liver transplantations with deceased donors. Major prospective trials are necessary to evaluate each preservation solution's particularities. The preservation solution availability in each transplantation center must guide its use at the present moment.
Collapse
|
45
|
Indirect Study of the 16O+ 16O Fusion Reaction Toward Stellar Energies by the Trojan Horse Method. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201611709013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
46
|
Studying astrophysical reactions with low-energy RI beams at CRIB. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201611709005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
47
|
Dental Health and Mortality in People With End-Stage Kidney Disease Treated With Hemodialysis: A Multinational Cohort Study. Am J Kidney Dis 2015; 66:666-76. [DOI: 10.1053/j.ajkd.2015.04.051] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Accepted: 04/29/2015] [Indexed: 01/28/2023]
|
48
|
Abstract
INTRODUCTION There is a greater risk of malignant tumors developing in kidney transplant patients. Due to this, early detection is of outmost importance, in which screening tests play an important role. METHODS We have conducted a survey among renal transplant recipients to assess individual risk factors. RESULTS Of 530 respondents, 55 developed post-transplantation tumors. Cutaneous tumors (36%) and kidney cancer (16%) were the most frequent. In total, 59% of recipients were over the age of 50, 61.7% were over the normal body-mass index range, 40.3% smoked or used to smoke, and 21.8% had diabetes. Five patients had hepatitis B virus and 11 were hepatitis C virus-positive. Malignancies developed significantly more frequent in men than in women (P = .04). The progressing of age (P = .0001) and the time elapsed after transplantation (P < .01) also were associated with a significant increase in the occurrence of post-transplantation tumors. CONCLUSION We have created a database to facilitate a more personalized and efficient screening program for immunocompromised patients.
Collapse
|
49
|
|
50
|
Measurement of pion, kaon and proton production in proton-proton collisions at [Formula: see text] TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2015; 75:226. [PMID: 26041975 PMCID: PMC4446008 DOI: 10.1140/epjc/s10052-015-3422-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Accepted: 04/20/2015] [Indexed: 05/14/2023]
Abstract
The measurement of primary [Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text] production at mid-rapidity ([Formula: see text] 0.5) in proton-proton collisions at [Formula: see text][Formula: see text] 7 TeV performed with a large ion collider experiment at the large hadron collider (LHC) is reported. Particle identification is performed using the specific ionisation energy-loss and time-of-flight information, the ring-imaging Cherenkov technique and the kink-topology identification of weak decays of charged kaons. Transverse momentum spectra are measured from 0.1 up to 3 GeV/[Formula: see text] for pions, from 0.2 up to 6 GeV/[Formula: see text] for kaons and from 0.3 up to 6 GeV/[Formula: see text] for protons. The measured spectra and particle ratios are compared with quantum chromodynamics-inspired models, tuned to reproduce also the earlier measurements performed at the LHC. Furthermore, the integrated particle yields and ratios as well as the average transverse momenta are compared with results at lower collision energies.
Collapse
|