1
|
Letter to the Editor: Regarding "Outcomes of Ceramic-On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study". J Arthroplasty 2023; 38:e39. [PMID: 37734831 DOI: 10.1016/j.arth.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/04/2023] [Accepted: 07/06/2023] [Indexed: 09/23/2023] Open
|
2
|
Letter to the Editor: A Nomogram That Characterizes a Patient's Odds of Developing Squeaking After Fourth-generation Ceramic-on-ceramic THA. Clin Orthop Relat Res 2023; 482:00003086-990000000-01372. [PMID: 37768867 PMCID: PMC10723890 DOI: 10.1097/corr.0000000000002872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 08/25/2023] [Indexed: 09/30/2023]
|
3
|
Letter to the Editor: Regarding "High Prevalence of Spino-pelvic Risk Factors in Patients With Postoperative Hip Dislocations". J Arthroplasty 2023; 38:e11. [PMID: 37085243 DOI: 10.1016/j.arth.2023.01.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 01/17/2023] [Accepted: 01/23/2023] [Indexed: 04/23/2023] Open
|
4
|
Abstract
Essential treatment methods for infected knee arthroplasty involve DAIR (debridement, antibiotics, and implant retention), and one and two-stage exchange arthroplasty. Aggressive debridement with the removal of all avascular tissues and foreign materials that contain biofilm is mandatory for all surgical treatment modalities. DAIR is a viable option with an acceptable success rate and can be used as a first surgical procedure for patients who have a well-fixed, functioning prosthesis without a sinus tract for acute-early or late-hematogenous acute infections with no more than four weeks (most favourable being < seven days) of symptoms. Surgeons must focus on the isolation of the causative organism with sensitivities to bactericidal treatment as using one-stage exchange. One-stage exchange is indicated when the patients have:minimal bone loss/soft tissue defect allowing primary wound closure, easy to treat micro-organisms, absence of systemic sepsis and absence of extensive comorbidities.
There are no validated serum or synovial biomarkers to determine optimal timing of re-implantation for two-stage exchange. Antibiotic-free waiting intervals and joint aspiration before the second stage are no longer recommended. The decision to perform aspiration should be made based on the index of suspicion for persistent infection. Re-implantation can be performed when the treating medical team feels that the clinical signs of infection are under control and serological tests are trending downwards.
Cite this article: EFORT Open Rev 2020;5:672-683. DOI: 10.1302/2058-5241.5.190069
Collapse
|
5
|
Long-term results of cementless total hip arthroplasty for the treatment of ankylosed hip. J Orthop Surg (Hong Kong) 2020; 27:2309499019858038. [PMID: 31262219 DOI: 10.1177/2309499019858038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE The purpose of this study was to report the long-term results of total hip arthroplasty (THA) for the treatment of ankylosed hip. METHODS Twenty-nine consecutive THAs were performed in 26 patients. The mean age of the patients at the time of the operation was 43.3 years (range, 19-69 years). We used cementless fixation in all hips and the mean duration of follow-up was 10.1 years (range, 4.5-20 years). Radiological evaluation of components, osteolysis, radiolucent lines and loosening were assessed. The Harris Hip Score (HHS), range of motion (ROM), limb-length discrepancy and walking capacity with or without any support were used preoperatively and at final follow-up for clinical evaluation. Survivorship analysis was conducted using the Kaplan-Meier method using second revision for any reason as the endpoint. RESULTS The mean HHS was 85.6 (range, 55-98) points and mean ROM was 110.5° for flexion. The mean limb-length discrepancy improved from 4.1 cm to 1.1 cm. Positive Trendelenburg sign was recorded in 31% of the patients and 24% of patients needed any support for walking postoperatively. We observed surgical complications related to abductor arm in 25% of the patients. Radiolucency on the acetabular side was seen on one or more zones in 15 patients (16 hips). One aseptic acetabular component loosening was observed. On the femoral side, 11 patients demonstrated non-progressive radiolucent lines and osteolysis around the stem was seen in four hips but there was no aseptic stem loosening. The Kaplan-Meier survival rate considering revision for any reason as the endpoint was 81.5%, for aseptic loosening 91.3%, for a worst-case scenario of 66.4% at 10 years. CONCLUSION Cementless fixation showed good to excellent results at 10 years. Preoperative and postoperative abductor status of the patient is critical for patient satisfaction.
Collapse
|
6
|
Dual-mobility cups in revision acetabular reconstructions: Short-term outcomes in high-risk patients for instability. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA 2019; 53:329-333. [PMID: 31281078 PMCID: PMC6819842 DOI: 10.1016/j.aott.2019.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 04/25/2019] [Accepted: 05/24/2019] [Indexed: 02/07/2023]
Abstract
Objective The aim of this study was to evaluate the performance of dual-mobility (DM) cup systems for revision total hip arthroplasty (rTHA) in patients who had high risk for instability. Methods We prospectively followed up 34 hips of 30 patients (27 females, 3 males; mean age: 66.1 (range: 33 to 89) years) who underwent rTHA with DM cups for aseptic loosening in 23 hips, infection treatment as second or single stage in nine hips, and instability in two hips. Clinical functions of the patients were evaluated using the Harris Hip Score (HHS), and radiological migration or loosening of the DM cups were recorded. The survival of the components was calculated with the Kaplan-Meier survival analysis and failure was defined as any dislocation of the polyethylene (PE) insert, intraprosthetic dislocation (IPD), aseptic loosening of any component or total hip system revision due to any reason. Results The mean duration of follow-up was 3.52 (range: 2.05 to 6.26) years. There was one dislocation of PE insert (2.9%), which was treated with closed reduction. There were two (5.8%) re-revisions for cemented DM cup due to migration. There was one PE insert and head change due to subacute infection. The mean HHS increased from 42.8 ± 6.7 (range: 34 to 60) points preoperatively to 87.3 ± 5.8 (range: 75 to 98) points postoperatively. The cumulative survival rate of the DM cup system was 91.2% (95% CI: 81.6–100%) with any revision, 94.1% (95% CI: 86.2–100%) with aseptic loosening and %97.1 (%95 CI: 91.4–100%) with dislocation as the end point at 3.5 years. Conclusion Dual-mobility cups may provide good stability and represent a good option for revision acetabular reconstruction in patients who have high risk for instability. Level of evidence Level IV, therapeutic study.
Collapse
|
7
|
Intraoperative neuromonitoring of anterior root muscle response during hip surgery under spinal anesthesia. J Clin Monit Comput 2018; 33:695-702. [PMID: 30415323 DOI: 10.1007/s10877-018-0212-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 10/10/2018] [Indexed: 11/25/2022]
Abstract
The aim of this study was to evaluate the anterior root muscle (ARM) response monitorability during total hip arthroplasty (THA) under spinal anesthesia. A total of 20 adults (64.6 ± 13.87 years old) were monitored using ARM response and free-run electromyography during THA. To elicit the ARM response from muscles, percutaneous stimulation of the lumbosacral roots was performed by self-adhesive electrodes placed over the skin of the projection of the first and third lumbar interspinous space (anode) and over the abdominal skin of the umbilicus (cathode). Latency and amplitude values of the ARM response were recorded from both sides (non-operated and operated) and from five muscles as follows: rectus femoris (RF), vastus lateralis (VL), biceps femoris long-head (BF), Tibialis Anterior (TA) and gastrocnemius. The most recorded ARM response in a muscle was the TA (n = 38); the least recorded AMR response in a muscle was the BF (n = 33). The mean stimulus intensities for the non-operated and the operated sides were 462.5 ± 112.8 V and 520.0 ± 172.3 V (p = 0.834), respectively. The mean latencies and amplitude values of the ARM response from muscles were as follows: 8.8 ± 1.4 ms; 98.8 ± 114.5 µV for RF; 9.8 ± 2.1 ms; 119.1 ± 122.23 µV for VL; 9.5 ± 1.6 ms; 39.6 ± 30.3 µV for BF; 15.1 ± 1.9 ms; 146.6 ± 150.9 µV for TA; 15.6 ± 2.4 ms; 81.0 ± 99.9 µV for Gastrocnemius. The present study demonstrates that the ARM response could easily and safely be obtained during THA under spinal anesthesia. This non-invasive technique may have a potential to detect early neurological deficit in patients who need complex hip surgery under spinal anesthesia.
Collapse
|
8
|
Dual offset metaphyseal-filling stems in primary total hip arthroplasty in dysplastic hips after a minimum follow-up of ten years. INTERNATIONAL ORTHOPAEDICS 2018; 43:2039-2046. [PMID: 30232526 DOI: 10.1007/s00264-018-4161-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 09/12/2018] [Indexed: 12/01/2022]
Abstract
PURPOSE The aim of this study was to assess the long-term performance of tapered one-third proximally coated stems in dysplastic hips. METHODS This study included 135 dysplasia patients (150 hips) who underwent a total hip arthroplasty and had a minimum follow-up of ten years. Single design tapered stems were used in all patients. There were 112 women (83%) and 23 men (17%) with a mean age of 45 years (23 to 72) at the time of surgery. The mean follow-up was 14.7 years (10 to 16.8). For clinical evaluation, the Harris Hip Score and Merle D'Aubigne scale were used pre-operatively and at the final follow-up. Implant survival was calculated using Kaplan-Meier survivorship analysis, with failure defined as a component revision for any reason. RESULTS Overall, one stem was revised for a deep infection. There were no other femoral stem revisions secondary to loosening, wear, periprosthetic fracture, or instability. Radiographic evaluation showed excellent stem osteointegration in all cases. Kaplan-Meier survivorship, with stem revision for any reason as the end point, was 98% at 14 years (95% confidence interval 92.5 to 99.8). CONCLUSION This study demonstrates that a dual offset tapered stem achieved excellent survivorship and stability, as well as good clinical outcome scores with minimal thigh pain and stress shielding in patients with arthritis and developmental dysplasia of the hip; a dual offset tapered stem may be a suitable option for primary total hip arthroplasty in this group.
Collapse
|
9
|
Abstract
INTRODUCTION The purpose of this study was to summarise the performance of dual-mobility cup systems for revision total hip arthroplasty in patients with abductor-trochanteric complex deficiency. METHODS We prospectively followed 17 patients (20 hips) with a mean age of 64.5 years (range 33-89 years) who underwent acetabular reconstruction with dual-mobility cups for aseptic loosening in 12 hips, infection treatment as second or single stage in 6 hips, and instability in 2 hips. All of the patients had abductor insufficiency. We evaluated the clinical Harris Hip scores (HHS) and radiographs for migration, loosening, and osteolysis. The survival of the components was calculated according to Kaplan-Meier survivorship analysis, and failure was defined as any dislocation, acetabular component or total hip revision for any reason. RESULTS The mean duration of follow-up was 38.1 months (range 24-98 months). There were 2 (12.5%) revisions for cemented cup migration after 11 months and 19 months respectively. There were no dislocations. At the last follow-up, the mean HHS increased from 42 points preoperatively to 86 points. The cumulative survival rate of the dual-mobility cup system was 93% (95% confidence interval 88-98.7%) at 5 years, with any revision as the end point. CONCLUSION Dual-mobility cups may provide excellent stability in patients with abductor-trochanteric complex insufficiency.
Collapse
|
10
|
Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty. J Orthop Sci 2018; 23:525-531. [PMID: 29503037 DOI: 10.1016/j.jos.2018.02.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 01/02/2018] [Accepted: 02/12/2018] [Indexed: 10/17/2022]
Abstract
BACKGROUND Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. METHODS Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. RESULTS The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. CONCLUSION Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage.
Collapse
|
11
|
Tapered stems one-third proximally coated have higher complication rates than cylindrical two-third coated stems in patients with high hip dislocation undergoing total hip arthroplasty with step-cut shortening osteotomy. Orthop Traumatol Surg Res 2017; 103:569-577. [PMID: 28300706 DOI: 10.1016/j.otsr.2017.01.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 01/13/2017] [Accepted: 01/20/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. HYPOTHESIS The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. MATERIALS AND METHODS Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. RESULTS Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. CONCLUSIONS There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. LEVEL OF EVIDENCE IV, retrospective study.
Collapse
|
12
|
Total hip arthroplasty with step-cut subtrochanteric femoral shortening osteotomy in high riding hip dislocated patients with previous femoral osteotomy. J Orthop Sci 2017; 22:517-523. [PMID: 28254154 DOI: 10.1016/j.jos.2017.01.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Revised: 12/11/2016] [Accepted: 01/30/2017] [Indexed: 02/09/2023]
Abstract
BACKGROUND To evaluate the long-term clinical and radiological outcomes of cementless total hip arthroplasty (THA) in high riding hip dislocated patients with previous proximal femoral osteotomy. METHODS Twenty-one consecutive patients with a mean age forty-two years were treated with cementless THA Step-cut subtrochanteric femoral osteotomy was performed in all twenty-eight hips. Metal on polyethylene (MoP) and ceramic on ceramic (CoC) bearings were used in two different consecutive time periods. The mean follow-up time was twelve years. Harris hip score, limb length discrepancy, complications, union status of the osteotomy, survivorship of constructs were the criteria for evaluation. RESULTS The mean Harris hip score improved from 39.5 to 88.7 points. The mean limb length discrepancy in unilateral cases decreased from 54.5 mm to 12.3 mm. The mean amount of femoral shortening was 37 mm. The mean union time was 3.5 months and there were no delayed union and non-union. There were three cup and two femoral revisions due to osteolysis in patients who had MoP. There was only one femoral revision in patients who had CoC. The Kaplan Meier survivorship with an end point of any revision of the stem and the acetabular component was 94% (95% CI, 75%-98%) and 92% (95% CI, 74%-99%) at ten years respectively. CONCLUSIONS Total hip arthroplasty with subtrochanteric step-cut femoral shortening is a successful technique to improve the hip functions and reconstruct limb length discrepancy in young patients with proximal femoral deformities.
Collapse
|
13
|
Oxidized zirconium on ceramic; Catastrophic coupling. Orthop Traumatol Surg Res 2017; 103:137-140. [PMID: 27871969 DOI: 10.1016/j.otsr.2016.10.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 08/29/2016] [Accepted: 10/17/2016] [Indexed: 02/02/2023]
Abstract
Oxidized zirconium (Oxinium™; Smith & Nephew, Memphis, TN, USA) articulated with polyethylene in total hip arthroplasty (THA) appeared to have the potential to reduce wear dramatically. The thermally oxidized metal zirconium surface is transformed into ceramic-like hard surface that is resistant to abrasion. The exposure of soft zirconium metal under hard coverage surface after the damage of oxidized zirconium femoral head has been described. It occurred following joint dislocation or in situ succeeding disengagement of polyethylene liner. We reported three cases of misuse of Oxinium™ (Smith & Nephew, Memphis, TN, USA) heads. These three cases resulted in catastrophic in situ wear and inevitable failure although there was no advice, indication or recommendation for this use from the manufacturer.
Collapse
|
14
|
Letter to the Editor on "Cartilage Status at Time of Arthroscopy Predicts Failure in Patients With Hip Dysplasia.". J Arthroplasty 2016; 31:2371-2. [PMID: 27133159 DOI: 10.1016/j.arth.2016.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Revised: 12/02/2015] [Accepted: 03/14/2016] [Indexed: 02/01/2023] Open
|
15
|
A novel [Mn 2(μ-(C 6H 5) 2CHCOO) 2(bipy) 4](bipy)(ClO 4) 2 complex loaded solid lipid nanoparticles: synthesis, characterization and in vitro cytotoxicity on MCF-7 breast cancer cells. J Microencapsul 2016; 33:575-584. [PMID: 27575255 DOI: 10.1080/02652048.2016.1228704] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Manganese (Mn)-based complexes have been drawing attention due to the fact that they are more effective than other metal complexes. However, the use of Mn(II)-based complexes in medicine remains limited because of certain side effects. The aim of this study was to investigate the cytotoxic and apoptotic effects of a novel Mn(II) complex [Mn2(μ-(C6H5)2CHCOO)2(bipy)4](bipy)(ClO4)2 and Mn(II) complex loaded solid lipid nanoparticles (SLNs) on MCF-7 and HUVEC control cells. The average diameter of Mn(II) complex was about 1120 ± 2.43 nm, while the average particle size of Mn(II) complex-SLNs was ∼340 ± 2.27 nm. The cytotoxic effects of Mn(II) complex and Mn(II)-SLNs were 86.8 and 66.4%, respectively (p < .05). Additionally, both Mn(II) complex (39.25%) and Mn(II)-SLNs (38.05%) induced apoptosis and increased the arrest of G0/G1 phase. However, Mn(II) complex exerted toxic effects on the HUVEC control cell (63.4%), whereas no toxic effects was observed when treated with Mn(II)-SLNs at 150 μM. As a consequence, SLNs might be potentially used for metal-based complexes in the treatment of cancer due to reducing size and toxic effects of metal-based complexes.
Collapse
|
16
|
Analysis of the cause, classification, treatment, outcome and associated injuries of pediatric pelvic ring fractures. ULUS TRAVMA ACIL CER 2016; 21:392-6. [PMID: 26388277 DOI: 10.5505/tjtes.2015.14868] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND Although pediatric pelvis fractures are relatively uncommon, long-term consequences and associated life-treating injuries often have a substantial impact for the rest of a child's life. The prognosis of pediatric pelvic fractures is better than that of the adults because of their greater elasticity, healing capacity and re-modelling. Fractures through the physis may lead to growth disturbance and/or acetabular dysplasia. Non-union is rare and mal-union is usually well-tolerated. The purpose of this study was to evaluate the results of a single trauma center and review the literature approach to pediatric pelvic fractures. METHODS Medical records were analyzed for diagnosis, the mechanism of injury, additional injuries, treatment methods, and complications. The types of fractures were classified according to Torode and Zieg classification. Patients were called back and seen at the clinic as a last follow up visit. RESULTS Twenty eight skeletally immature patients, under the age of 12, were treated for pelvic fracture from 1997 to 2012. Mean age was 6.8±2.4 years. Three children with an unstable pelvic ring injury required pelvic external fixation. One patient died due to pelvic hemorrhage postoperatively. Mean follow up was 5.3±3.6 years. CONCLUSION Pediatric pelvic fractures are rare but life-threating injuries. Overall good or excellent long-term results can be expected in most cases with appropriate timing and treatment.
Collapse
|
17
|
Vibrational spectroscopic investigation of methyl(5-[2-thienylcarbonyl]-1H-benzimidazol-2-yl: A comparative density functional study. J STRUCT CHEM+ 2014. [DOI: 10.1134/s002247661403007x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
18
|
The effect of strut allograft and its position on Vancouver type B1 periprosthetic femoral fractures: a biomechanical study. J Arthroplasty 2014; 29:1485-90. [PMID: 24656637 DOI: 10.1016/j.arth.2014.02.017] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Revised: 01/19/2014] [Accepted: 02/13/2014] [Indexed: 02/01/2023] Open
Abstract
The aim of this study is to assess the biomechanical advantage of adding strut allograft and the effect of its position on the construct in Vancouver type B1 fractures. Fifteen forth-generation synthetic femurs were used and created a fracture model at the tip of prosthesis, and subsequently fixated with a lateral plate only, lateral plate and medial strut, lateral plate and anterior strut. Rotational and axial tests were performed. In all loading tests, the plate with medial strut group was stiffer than the other constructs and had higher failure load values and had less displacement in the fracture site. A combination of a plate with a medial strut allograft provides more mechanical stability on periprosthetic femoral fractures near the tip of a total hip arthroplasty.
Collapse
|
19
|
Mid-term result of ceramic bearings in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2014; 38:2027-31. [DOI: 10.1007/s00264-014-2387-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Accepted: 05/14/2014] [Indexed: 11/29/2022]
|
20
|
Congenital agenesis of pubis and bilateral cryptorchidism: A case report. Int J Surg Case Rep 2014; 5:694-8. [PMID: 25194607 PMCID: PMC4189070 DOI: 10.1016/j.ijscr.2014.07.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 07/12/2014] [Accepted: 07/30/2014] [Indexed: 11/10/2022] Open
Abstract
Agenesis of the pubis is a very rare clinical deformity which can be a sign of urogenital abnormalities. To report a rare condition would help clinicians to diagnose co-morbidities which may affect children remaining life. This is a rare pattern of associated anomalies confined to a localized region of the body. Somatic mutations may responsible for developmental abnormalities of mesoderm from which the pubic bones and urogenital structures develop. An isolated X-ray finding of ramus pubis agenesis may associate with cryptorchidism or several other urogenital malformations.
INTRODUCTION Agenesis of the pubic bone, as evidenced in the world literature, is a very rare clinical and congenital abnormality. Several disorders may occur with hypoplasia of the pubis. PRESENTATION OF CASE Here, we report a rare longer follow-up case of the congenital unilateral agenesis of the superior ramus of pubic bone with bilateral undescended testes, osteoporosis, cranial malformations, acetabular dysplasia, unilateral shortening of the lower extremity and an abnormal gait pattern. DISCUSSION Somatic mutations may responsible for developmental abnormalities of the mesoderm from which the pubic bones and urogenital structures develop. CONCLUSION An isolated x-ray finding of ramus pubis agenesis may associate with cryptorchidism or several other urogenital malformations.
Collapse
|
21
|
Does obesity negatively affect the functional results of arthroscopic partial meniscectomy? A retrospective cohort study. Arthroscopy 2013; 29:232-7. [PMID: 23270789 DOI: 10.1016/j.arthro.2012.08.017] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2012] [Revised: 07/01/2012] [Accepted: 08/09/2012] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the impact of body mass index (BMI) on early functional results of patients who undergo isolated partial meniscectomy. METHODS The functional results for 1,090 patients who underwent partial meniscectomy, in 2 different orthopaedic clinics, were evaluated retrospectively. The study includes cases with arthroscopic partial meniscectomy for isolated meniscal tears; patients with concomitant knee pathology were excluded. Three hundred forty-one (31%) patients with isolated lateral meniscal tears, 628 (58%) patients with isolated medial meniscal tears, and 121 (11%) patients with both medial and lateral meniscal tears underwent arthroscopic partial meniscectomy. We divided these patients into 3 subgroups on the basis of their BMI; <26, between 26 and 30, ≥30. Preoperative functional results were compared with 1-year postoperative follow-up results using the International Knee Documentation Committee (IKDC),(26) Lysholm Knee Scale,(27) and Oxford Scoring System(28) scores. RESULTS According to all 3 knee scales, age, side of lesion, and tear type had no effect on functional outcome. When compared with the group with BMI <26, the patients with BMI between 26 and 30 and the patients with BMI ≥30 had significantly worse outcomes as measured by the IKDC, Oxford Scoring System, and Lysholm Knee Scale scores. Patients with BMI between 26 and 30 and ≥30 did not have significantly different functional outcomes. CONCLUSIONS Short-term outcomes after arthroscopic partial menisectomy reflect significant improvement in subjective outcome. However, patients with moderate or significant obesity (BMI >26) have inferior short-term outcomes compared with nonobese patients. LEVEL OF EVIDENCE Level IV, therapeutic case series.
Collapse
|
22
|
Abstract
BACKGROUND Treating infected ankles in patients with neuropathy is difficult, and complications are frequently encountered. Eradication of infection and effective arthrodesis are required for a successful outcome. The purpose of this study was to evaluate the outcomes of patients with Charcot neuropathy whose infected ankles were treated with a retrograde, antibiotic-coated, locked intramedullary nail. METHODS We analyzed 5 patients with infected neuroarthropathy of the ankle joint. Three patients had failed treatment with the circular external fixator for infected neuroarthropathy of the ankle. The other 2 were treated primarily by this technique. All patients were treated with surgical nonunion repair, arthrodesis, and insertion of an antibiotic-coated, locked intramedullary nail. The average age was 59 years (range, 46 to 82 years). The average follow up period was 18 months (range, 12-24 months). RESULTS The average time taken for radiological healing was 4.1 months (range, 4-4.5 months). In all patients, bony union was achieved and infection was eradicated. There were no cases of hardware failure. CONCLUSION Antibiotic-coated nails were used to treat infected ankle nonunions and infected distal tibial fractures in Charcot patients with successful bony union, fusion, and eradication of infection. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
23
|
Abstract
The purpose of this study was to evaluate the effect of the AperFix device (Cayenne Medical, Inc, Scottsdale, Arizona), composed of polyetheretherketone (PEEK) polymer, on tunnel widening after hamstring anterior cruciate ligament (ACL) reconstruction as compared with 2 other fixation devices: the TransFix (Arthrex, Inc, Naples, Florida) and the EndoButton (Smith & Nephew Endoscopy, Mansfield, Massachusetts). Sixty-seven patients with isolated total ACL ruptures who underwent arthroscopically assisted reconstruction using hamstring autografts at the authors' institution were included in the study. Patients were assigned into 1 of 3 groups in a nonrandomized fashion: AperFix (n=18), TransFix (n=29), and EndoButton (n=20). Mean follow-up was 30 months. Tunnel widening measurements were performed on anteroposterior and lateral digital plain radiographs taken in postoperative week 1 and at final follow-up. Laxity testing, Lysholm scoring, and arthrometric evaluation were performed.All 3 graft fixation devices resulted in significant tunnel widening in both tibial and femoral tunnels at final follow-up when compared with the immediate postoperative period. Tunnel widening between groups was not significantly different in terms of coronal and sagittal femoral tunnel diameters. Tibial tunnel diameter increase in the sagittal plane in the EndoButton group was significantly smaller than that in the TransFix and AperFix groups. No correlation was found between the amount of tunnel enlargement and clinical outcomes of ACL surgery. This study's findings suggest that tunnel enlargement after ACL reconstruction is influenced by the type of graft fixation on the tibial side irrespective of clinical outcome, and PEEK polymer does not have an effect on tunnel widening after hamstring ACL reconstruction.
Collapse
|
24
|
DARBEPOETIN TREATMENT AFTER ETHANOL TOXICITY : AN EXPERIMENTAL STUDY IN RATS. FASEB J 2007. [DOI: 10.1096/fasebj.21.6.a1278-a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Effects of iloprost on visual evoked potentials and brain tissue oxidative stress after bilateral common carotid artery occlusion. Prostaglandins Leukot Essent Fatty Acids 2006; 74:373-8. [PMID: 16687243 DOI: 10.1016/j.plefa.2006.03.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2005] [Accepted: 03/19/2006] [Indexed: 11/18/2022]
Abstract
Effects of iloprost on visual evoked potentials and oxidant/antioxidant status were evaluated after bilateral carotid artery occlusion. There were three experimental groups; Sham (S) group (n=10), bilateral common carotid artery occluded (BCCAO) group (n=10) and after bilateral common carotid artery occlusion, iloprost-treated (BCCAOI) group (n=10). Iloprost was administered (0.5ng/kg/day) for 10 days by intraperitoneal injection. N(2) and P(2) latencies (millisecond) and N(2)-P(2) (microV) amplitudes were recorded 10 days after operation for evaluating VEPs. The rats were sacrificed by decapitation immediately after recording of VEPs. Malondialdehyte (MDA), glutathione (GSH), Cu-Zn superoxide dysmutase (SOD) were studied spectrophotometricly. After BCCAO, MDA levels were increased, GSH and Cu-Zn SOD levels were decreased significantly, and abnormal VEPs parameters were observed. Iloprost treatment after BCCAO decreased MDA and increased GSH levels significantly. Low Cu-Zn SOD levels and impaired VEPs remained after iloprost treatment. Iloprost treatment may protect the brain tissue from oxidative damage during cerebral hypoperfusion.
Collapse
|
26
|
Quantitative telomerase activity in malignant, benign and normal gynecological tissues. EUR J GYNAECOL ONCOL 2005; 26:83-6. [PMID: 15755008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate quantitative telomerase activity in malignant, benign and normal gynecological tissue samples by using the Telomerase-PCR ELISA kit, and to determine a cut-off level for malignancy by this quantitative method. MATERIALS AND METHODS Fifty gynecological tumors, 27 benign gynecological disorders and 29 normal tissues were analyzed by the Telomerase-PCR ELISA kit. All tissues were confirmed by a pathologist. A ROC (receiver operator characteristic) curve was drawn to determine a threshold level best discriminating malignant tissues from benign pathologies and normal tissues. Telomerase activity was compared in malignant, benign and normal tissues. RESULTS The mean level of telomerase activity of the malignant tumor samples (1.03 +/- 0.53 units) was significantly (p < .001) higher than the normal tissues (0.13 +/- 0.07 units) and benign pathologies (0.37 +/- 0.25 units). The cut-off point to differentiate malignant samples from benign samples was set at 0.42 units, where the sensitivity was 93.8% and the specificity was 89.3%. Positive predictive value was 84% and negative predictive value was 89.3%. There was a significant difference in telomerase activity between malignant, benign and normal tissues within each histological group. CONCLUSION In this preliminary study, the telomerase-PCR ELISA method was found to have a high sensitivity and specificity to differentiate malignant gynecological tissues from benign tissues.
Collapse
|
27
|
Abstract
The aim of the present study was to investigate the diagnostic efficacy of telomerase activity for discrimination of malignant and benign pleural effusions. Pleural effusions were collected from 109 consecutive patients in whom the diagnosis was confirmed with cytological and/or histological examinations. Cytological samples were classified as malignant (n=63) and benign (n=46). Telomerase activity was determined with the polymerase chain reaction-based telomeric repeat amplification protocol assay. Telomerase activity was detected in 52 (82.5%) and nine (19.6%) samples from the malignant and benign groups, respectively, which was a significant difference. The sensitivity rate of cytological examination when combined with telomerase activity (92.1%) was significantly greater than that of cytological examination alone (53.9%). The sensitivity and specificity of telomerase activity were 82.5 and 80.4%, respectively. Diagnostic accuracy of telomerase activity was 81.6%. Telomerase activity is a highly sensitive diagnostic biomarker for malignancy and may be used as an adjunct to cytological findings in determining malignant pleural effusions.
Collapse
|
28
|
TELOMERASE ACTIVITY IN GYNECOLOGIC TISSUES. Int J Gynecol Cancer 2003. [DOI: 10.1136/ijgc-00009577-200303001-00223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|