1
|
Ambrožová I, Chvátil D, Cimmino A, Motta S, Olšanský V, Olšovcová V, Truneček R, Šolc J, Velyhan A, Versaci R. CHARACTERIZATION OF OSL AND TL DOSIMETERS WITH DATA COLLECTED AT THE MT25 CYCLIC ELECTRON ACCELERATOR. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01709-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
2
|
Peyres V, Marijuán MJ, Šuráň J, Šolc J, Kovář P, Skála L, Grísa T, Gómez Caloca C, Saez Vergara JC. Validation of a free release measurement facility on a decommissioning site. Appl Radiat Isot 2021; 178:109968. [PMID: 34619627 DOI: 10.1016/j.apradiso.2021.109968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 09/26/2021] [Indexed: 11/30/2022]
Abstract
The paper summarizes measurements and the Monte Carlo simulations performed to adapt the high purity germanium (HPGe) detectors of the system to the particular tasks of the decommissioning site. The work carried out for the installation and adaptation in CIEMAT of the prototype 'SuperMum', developed in the framework of the European MetroDecom II project for segregation and declassification of materials is described. The activities related to the validation of the prototype for the specific needs of a real Waste Management Unit are presented. Monte Carlo models of the SuperMum have been developed at CIEMAT and CMI using different codes and adapted to the geometries used (big-bag containers with the material volume of up to 0.5 m3). Uncertainty budget reporting tailored for the possible deviations between Monte Carlo assumptions and real waste have been analyzed. Data for several filling levels and activity distributions have been measured with reference sources and a good agreement has been obtained with calculated values.
Collapse
Affiliation(s)
- V Peyres
- CIEMAT, Avenida Complutense 40, Madrid, 28040, Spain.
| | - M J Marijuán
- CIEMAT, Avenida Complutense 40, Madrid, 28040, Spain
| | - J Šuráň
- CMI, Okruzni 31, 638 00, Brno, Czech Republic
| | - J Šolc
- CMI, Okruzni 31, 638 00, Brno, Czech Republic
| | - P Kovář
- CMI, Okruzni 31, 638 00, Brno, Czech Republic
| | - L Skála
- Nuvia, Modrinova 1094, 674 01, Trebic, Czech Republic
| | - T Grísa
- Nuvia, Modrinova 1094, 674 01, Trebic, Czech Republic
| | | | | |
Collapse
|
3
|
Bobin C, Bouchard J, Chisté V, Collins SM, Dryák P, Fenwick A, Keightley J, Lépy MC, Lourenço V, Robinson AP, Sochorová J, Šolc J, Thiam C. Activity measurements and determination of nuclear decay data of 166Ho in the MRTDosimetry project. Appl Radiat Isot 2019; 153:108826. [PMID: 31525708 DOI: 10.1016/j.apradiso.2019.108826] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 07/23/2019] [Accepted: 07/26/2019] [Indexed: 11/19/2022]
Abstract
Holmium-166 is a high-energy β--emitter radionuclide (~ 1.8 MeV) with a short half-life (~26.8h) that offers great potential as an alternative to 90Y for the treatment of liver cancer based on radioembolization. The possibility of quantitative Single Photon Emission Computed Tomography (SPECT) imaging of the main γ-ray emission at 80.6 keV, in addition to strong paramagnetic properties suitable for Magnetic Resonance Imaging (MRI), complement this therapeutic potential. The present paper describes the measurements carried out in three European radionuclide metrology laboratories for primary standardization of 166Ho and new determinations of X- and γ-ray photon-emission intensities in the framework of the European EMPIR project MRTDosimetry. New half-life measurements were also performed.
Collapse
Affiliation(s)
- C Bobin
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France.
| | - J Bouchard
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France
| | - V Chisté
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France
| | - S M Collins
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom
| | - P Dryák
- Czech Metrology Institute, Okruzni 31, 638 00, Brno, Czech Republic
| | - A Fenwick
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom
| | - J Keightley
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom
| | - M-C Lépy
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France
| | - V Lourenço
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France
| | - A P Robinson
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom; University of Manchester, Oxford Road, Manchester, M13 9PL, United Kingdom; Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Wilmslow Road, M20 4BX, Manchester, United Kingdom
| | - J Sochorová
- Czech Metrology Institute, Okruzni 31, 638 00, Brno, Czech Republic
| | - J Šolc
- Czech Metrology Institute, Okruzni 31, 638 00, Brno, Czech Republic
| | - C Thiam
- CEA, LIST, Laboratoire National Henri Becquerel, (LNE-LNHB), 91191, Gif-sur-Yvette Cedex, France
| |
Collapse
|
4
|
Vykydal Z, Andrlík M, Bártová H, Králík M, Šolc J, Vondráček V. MEASUREMENT OF SECONDARY NEUTRONS GENERATED DURING PROTON THERAPY. Radiat Prot Dosimetry 2016; 172:341-345. [PMID: 26656077 DOI: 10.1093/rpd/ncv504] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 11/05/2015] [Accepted: 11/06/2015] [Indexed: 06/05/2023]
Abstract
Measurements described in this article were carried out with the aim of evaluating risks of the patient exposure to secondary neutrons during treatment at the Proton Therapy Centre Prague. The neutron spectral fluence was measured by means of the extended Bonner sphere spectrometer (EBS). The article presents secondary neutron spectral fluences obtained by the EBS with passive thermoluminescent detectors, i.e. pairs of 6LiF and 7LiF chips. Measurements were performed in two positions: the first one behind the Nylon 6 phantom, and the second one close to the range shifter to evaluate their contribution to the generation of neutrons. Both the Nylon 6 phantom and the range shifter were irradiated with a pencil beam of protons 4 mm in diameter and the energy of 200 MeV. The results are supplemented with the values of effective dose derived from neutron spectral fluences.
Collapse
Affiliation(s)
- Z Vykydal
- Czech Metrology Institute, Radiová 1a, Praha 10 102 00, Czech Republic
| | - M Andrlík
- Proton Therapy Center Praha, Budínova 1a, Praha 8 180 00, Czech Republic
| | - H Bártová
- Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, Praha 1 115 19, Czech Republic
| | - M Králík
- Czech Metrology Institute, Radiová 1a, Praha 10 102 00, Czech Republic
| | - J Šolc
- Czech Metrology Institute, Radiová 1a, Praha 10 102 00, Czech Republic
| | - V Vondráček
- Proton Therapy Center Praha, Budínova 1a, Praha 8 180 00, Czech Republic
| |
Collapse
|
6
|
Abstract
The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a (10)B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.
Collapse
Affiliation(s)
- M Králík
- Czech Metrology Institute, CZ-102 00 Prague 10, Czech Republic.
| | | | | | | | | | | |
Collapse
|