1
|
Arthroscopic stabilization of anterior shoulder instability: a historical perspective. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2003; 60:124-9. [PMID: 12102398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
The role of arthroscopic procedures in the management of glenohumeral instability continues to evolve and represents an effective alternative for addressing the pathology associated with this condition. Patient selection criteria, operative techniques, and implants all continue to evolve and have resulted in improved rates of success. Arthroscopic procedures benefit patients by avoiding the common morbidities associated with the disruption of the anterior soft tissues, including a loss of external rotation associated with open procedures. Arthroscopic procedures remain technically demanding and require skills to address all of the existing pathology. The surgeon must be prepared to address many conditions beyond the Bankart lesions including glenoid bone lesions. capsular laxity, rotator interval lesions, and SLAP lesions. In addition to the documentation of recurrence, the success of this procedure must be evaluated within the context of retained ranges of motion, recovery time, proprioceptive control, and the return to prior levels of activity. Further studies are necessary to continue to validate the efficacy of arthroscopic stabilization.
Collapse
|
2
|
Laboratory evaluation of hip fracture fixation devices. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2003; 60:114-23. [PMID: 12102397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
3
|
Bilateral carpal tunnel syndrome in a child on growth hormone replacement therapy: a case report. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2002; 60:94-5. [PMID: 12003362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
|
4
|
Orthopaedic manifestations of systemic lupus erythematosus. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2002; 60:29-34. [PMID: 11759575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
Systemic lupus erythematosus (SLE) is a chronic inflammatory autoimmune disease of unknown origin. It affects multiple organ systems, but most frequently the musculoskeletal system. Highly variable manifestations include small and large joint involvement, spinal involvement, periarticular tissue symptoms, and complications associated with chronic steroid use such as osteonecrosis, osteoporosis, and stress fractures. The following review summarizes the common orthopaedic manifestations of SLE.
Collapse
|
5
|
The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty. J Arthroplasty 2001; 16:759-67. [PMID: 11547375 DOI: 10.1054/arth.2001.25507] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
The effect of stem length, diameter, and mode of fixation on the motion and stress transfer of a cemented tibial tray were evaluated for in 12 cadaver knees. There was a significant decrease in motion of the tibial tray with increasing press-fit stem length (75-150 mm) and increasing stem diameter (10-14 mm). Cemented tibial stems showed significantly less tray motion than uncemented stems. The short cemented stems produced tray stability equivalent to long press-fit stems. Although there was a trend for increased proximal tibial stress shielding with the use of cement and longer, wider stems, the trend was not statistically significant. Modular, press-fit stems can achieve tray stability similar to a smaller cemented stem and can avoid the potential problems with cement.
Collapse
|
6
|
Abstract
Intra-articular lipoma is an exceedingly rare diagnosis. There have been less than 15 documented cases of an intra-articular lipoma of the knee joint. This report presents the first description of an intra-articular knee lipoma treated entirely by arthroscopic methods. Preoperative history, examination, and imaging studies are reviewed. Intraoperative findings, treatment, and postoperative evaluation are discussed as well. Symptomatic intra-articular lipoma of the knee joint can be successfully treated by arthroscopic resection. Differentiating intra-articular lipoma from lipoma arborescens, a similar but more common condition, is important with regards to optimal treatment.
Collapse
|
7
|
Radiographic comparison of grit-blasted hydroxyaptite and arc-deposited hydroxyapatite acetabular components. A four-year follow-up study. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2001; 59:144-8. [PMID: 11126716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
High rates of aseptic loosening have been reported for microstructured hydroxyapatite-coated acetabular components. A macrostructured component surface (arc-deposition) not only improves resistance to shear forces experienced by the acetabular component and increases initial stability, but also provides channels for bone ingrowth. The purpose of this investigation was to radiographically compare a series of grit-blasted (microstructured) and arc-deposited (macrostructured) hydroxyapatite-coated acetabular components. A minimum 4-year retrospective radiographic analysis of acetabular components was performed on a total of 50 total hip arthroplasties. At 4 years, arc-deposited components were associated with fewer radiolucent lines in all Charnley zones, particularly Charnley zone III. While the 4-year results for arc-deposited hydroxyapatite acetabular components are superior to their microstructured predecessors, long-term results are still unknown.
Collapse
|
8
|
Spontaneous rib fracture during pregnancy. A case report and review of the literature. BULLETIN (HOSPITAL FOR JOINT DISEASES (NEW YORK, N.Y.)) 2001; 59:163-5. [PMID: 11126720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
No studies have demonstrated a direct relationship between pregnancy and rib fracture. A case of spontaneous rib fracture in the third trimester presents the opportunity to examine factors unique to pregnancy that may predispose the patient to stress fractures of the lower ribs. A 28-year old woman in week 31 of her pregnancy presented with the chief complaint of acute onset of right upper quadrant pain. A chest radiograph demonstrated a minimally displaced fracture of the right 10th rib. During pregnancy, the enlarging uterus causes certain opposing muscular forces to act on the ribs, making them more susceptible to fracture after minimal trauma or after repeated stresses such as a chronic cough.
Collapse
|
9
|
Synovial chondromatosis of the elbow. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 2001; 30:223-4. [PMID: 11300131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Synovial chondromatosis is an uncommon disorder with rare occurrence in the elbow. Case reports in the literature for elbow synovial chondromatosis have described presenting symptoms secondary to peripheral nerve compressions or localized bursitis. We discuss a case of synovial chondromatosis of the elbow that presented as an isolated soft-tissue mass over the radial head-more suggestive of a soft-tissue tumor than of synovial chondromatosis.
Collapse
|
10
|
Distal biceps tendon ruptures: a historical perspective and current concepts. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 2001; 30:193-200. [PMID: 11300127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Distal biceps tendon rupture is a relatively rare injury most commonly seen in the dominant extremity of men between 40 and 60 years of age. It occurs when an eccentric extension force is applied to a contracting biceps muscle. The hallmark finding is a palpable defect in the distal biceps, which is accentuated by elbow flexion. Radiographic evaluation is usually not necessary. Acute surgical repair is advocated for optimal return of function by either a one-incision or a modified two-incision muscle-splitting technique. The arm is protected for 6 to 8 eight weeks after surgery. Unrestricted range of motion and gentle strengthening may begin after the 6 - 8 week protection period. Return to unrestricted activity is usually allowed by 5 months after surgery.
Collapse
|
11
|
|
12
|
Long-term follow-up of the one-bone forearm procedure. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 2000; 29:969-72. [PMID: 11140352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
The one-bone forearm procedure can be a successful salvage option for forearm stability in selected patients and is indicated if instability and bone loss are irreparable by other means. We report a case of a dysfunctional arm secondary to radical débridement of the ulna after osteomyelitis treated successfully with a one-bone forearm procedure and followed up for 8 years.
Collapse
|
13
|
The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation. J Arthroplasty 2000; 15:761-6. [PMID: 11021452 DOI: 10.1054/arth.2000.8193] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Patellofemoral complications, instability, and tibial polyethylene wear after total knee arthroplasty (TKA) resulting from malrotation of the tibial or femoral components (or both) may be difficult to diagnose based on physical examination and standard knee radiographs. The preoperative assessment of implant rotational alignment is critical in planning treatment because the femoral or tibial component (or both) may need to be revised if malpositioned. The purpose of this study was to ascertain the accuracy of computed tomography (CT) scan for determining rotational alignment of femoral and tibial components in TKA. TKA components were inserted in human cadaver specimens at neutral and 5 degrees of external or internal rotation. For each position, the amount of rotation, determined from digital photographs, was compared with CT scan. The correlation coefficient between these two values averaged 0.87, which was significant at P < .05. The CT scan protocol described in this study can be applied clinically to patients with patellofemoral complaints to confirm or rule out the presence of component malrotation.
Collapse
|
14
|
Abstract
Schuhli locking nuts can be used in poor quality cortical bone to enhance fixation stability as an alternative to cement augmented screws. This study compared the fixation strength and stability of plate constructs using Schuhli locking nuts with standard screws and cement augmented screws for fixation of simulated humeral shaft fractures in a test model with osteoporosis. The constructs were tested in axial compression, 4-point bending, and torsion to determine fixation stability. The humeri were cycled in torsion (4.5 Nm) for 1000 cycles to simulate upper extremity use during the early postoperative period and retested for stability. The Schuhli locking nuts and cement augmented screws had significantly greater fixation stability than the standard screws before (range, 6-14 times greater) and after cycling in torsional loading (range, 3-3.6 times greater). Although cement augmented screws and Schuhli augmentation showed increased fixation stability compared with the standard screws in axial and 4-point bending before cycling (range, 1.3-1.4 times greater), this was not significant. Compared with Schuhli fixation, cement augmented screws showed no significant difference in fixation stability in all loading modes before and after cycling. Schuhli locking nuts offer the stability of cement augmentation while avoiding its potential adverse effects on fracture healing with extravasation and thermal necrosis.
Collapse
|
15
|
Anticoagulant treatment of thromboembolism with intravenous heparin therapy in the early postoperative period following total joint arthroplasty. J Bone Joint Surg Am 2000; 82:207-12. [PMID: 10682729 DOI: 10.2106/00004623-200002000-00006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Treatment of thromboembolism with intravenous heparin therapy in the early postoperative period after total joint arthroplasty has been associated with a high rate of complications. The purpose of the present study was to compare the rate of bleeding complications in a group of patients who required intravenous heparin therapy for the treatment of thromboembolism after total hip or knee arthroplasty with the rate in a control group of patients who received only prophylactic anticoagulation. METHODS The postoperative courses of forty-four consecutive patients who were managed with intravenous administration of heparin and oral administration of warfarin for the treatment of a thromboembolic event following unilateral total hip or knee arthroplasty were compared with those of a control group of 376 consecutive patients who had these same procedures but did not have a thromboembolic complication. The patients in the control group were managed with prophylactic anticoagulation with use of enoxaparin. Sixty-eight percent (thirty) of the forty-four patients in the heparin group received the initial dose of heparin on or before the fourth postoperative day, and 82 percent (thirty-six) received an initial bolus of 5000 units of heparin at the initiation of therapy. RESULTS The rate of bleeding complications was 9 percent (four of forty-four) in the heparin group, compared with 6 percent (twenty-three of 376) in the control group (p = 0.44). The mean transfusion requirement in the heparin group (1.8 units of packed red blood cells) was significantly greater than that in the control group (0.8 unit) (p < 0.0001). Three of the four patients who had a bleeding complication while receiving heparin and warfarin had coagulation parameters that were substantially higher than recommended levels. The mean duration of hospitalization in the heparin group (fifteen days) was significantly longer than that in the control group (seven days) (p < 0.0001). CONCLUSIONS The results of the present study suggest that the use of intravenous heparin therapy for the treatment of thromboembolism in the early postoperative period after total joint arthroplasty is associated with a rate of bleeding complications that is similar to that associated with the use of prophylactic anticoagulation with use of enoxaparin alone. One should expect an increased transfusion requirement and a longer duration of hospitalization for patients who require intravenous heparin therapy for the treatment of a thromboembolic event.
Collapse
|
16
|
New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation. THE JOURNAL OF TRAUMA 2000; 48:87-92. [PMID: 10647571 DOI: 10.1097/00005373-200001000-00015] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND A comminuted, intra-articular distal femur fracture was surgically treated by the authors with a locked, double-plating technique because fixation stability could not be initially achieved by using a standard double-plating technique. The purpose of this study was to determine biomechanically whether a locked double-plate construct would enhance fixation stability compared with a nonlocked double-plate construct. METHODS Six matched pairs of mildly osteopenic femurs were selected and all had a reproducible intra-articular fracture pattern created. Each pair underwent fixation with either a double-plating construct or a locked, double-plating construct that was randomly assigned. The instrumented femurs were then mechanically tested in several loading modes to determine fixation stability. After initial testing, specimens were cyclically loaded and retested for stability. RESULTS The locked, double-plating construct provided significantly greater fixation stability than the standard double-plating construct in precycling and postcycling biomechanical testing. CONCLUSION The technique described is particularly applicable for severely comminuted fractures of the distal femur and fractures in osteopenic bone with poor screw purchase. It offers a simple alternative for enhancing fixation stability, which avoids the potential complications of methylmethacrylate-enhanced screw fixation.
Collapse
|
17
|
Abstract
A retrospective clinical and radiographic analysis was performed on 58 patients (60 hips; mean age at time of surgery, 45.2 years) at a minimum of 10-year follow-up (mean, 12.7 years) after total hip replacement using a ceramic-on-ceramic hearing total hip implant (Autophor, Smith and Nephew, Memphis, TN). Mean wear rate at final follow-up was 0.21 mim, averaging 0.016 mm/y. There were no cases of periprosthetic osteolysis in the acetabuulum or femur. For the unrevised components, there were 3 (5%) cases of protrusio acetabuli and 4 (7%) cases of acetabular component loosening. On the femoral side, 78.3% had distal pedestal formation, and 83% had greater than 2 mm implant-bone radiolucencies in more than 5 Gruen zones as a result of gross motion of the stem. Despite radiographic evidence of implant loosening, this hard bearing articulation functioned well in vivo for more than 12 years with remarkably low wear--approximately one tenth the rate reported for metal-on-polyethylene total hip bearings.
Collapse
|
18
|
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine (Phila Pa 1976) 1999; 24:1521-6. [PMID: 10457570 DOI: 10.1097/00007632-199908010-00004] [Citation(s) in RCA: 165] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN A biomechanical study comparing two materials for augmentation of osteoporotic vertebral bodies and vertebral bodies after compression fracture. OBJECTIVES To compare an injected, biodegradable calcium phosphate bone substitute with injected polymethylmethacrylate bone cement for strengthening osteoporotic vertebral bodies and improving the integrity of vertebral compression fractures. SUMMARY OF BACKGROUND DATA Injection of polymethylmethacrylate bone cement into fractured vertebral bodies has been used clinically. However, there is concern about thermal damage to the neural elements during polymerization of the polymethylmethacrylate bone cement as well as its negative effects on bone remodeling. Biodegradable calcium phosphate bone substitutes have been studied for enhancement of fixation in fractured vertebrae. METHODS Forty fresh osteoporotic thoracolumbar vertebrae were used for two separate parts of this study: 1) injection into osteoporotic vertebrae: intact control (n = 8), calcium phosphate (n = 8), and polymethylmethacrylate bone cement (n = 8) groups. Each specimen then was loaded in anterior compression until failure; 2) injection into postfractured vertebrae: calcium phosphate (n = 8) and polymethylmethacrylate bone cement (n = 8) groups. Before and after injection, the specimens were radiographed in the lateral projection to determine changes in vertebral body height and then loaded to failure in anterior bending. RESULTS For intact osteoporotic vertebrae, the average fracture strength was 527 +/- 43 N (stiffness, 84 +/- 11 N/mm), 1063 +/- 127 N (stiffness, 157 +/- 21 N/mm) for the group injected with calcium phosphate, and 1036 +/- 100 N (stiffness, 156 +/- 8 N/mm) for the group injected with polymethylmethacrylate bone cement. The fracture strength and stiffness in the calcium phosphate bone substitute group and those in the polymethylmethacrylate bone cement group were similar and significantly stronger than those in intact control group (P < 0.05). For the compression fracture study, anterior vertebral height was increased 58.5 +/- 4.6% in the group injected with calcium phosphate and 58.0 +/- 6.5% in the group injected with polymethylmethacrylate bone cement as compared with preinjection fracture heights. No significant difference between the two groups was found in anterior vertebral height, fracture strength, or stiffness. CONCLUSION This study demonstrated that the injection of a biodegradable calcium phosphate bone substitute to strengthen osteoporotic vertebral bodies or improve vertebral compression fractures might provide an alternative to the use of polymethylmethacrylate bone cement.
Collapse
|
19
|
Catastrophic failure of a cemented, collarless, polished, tapered cobalt-chromium femoral stem used with impaction bone-grafting. A report of two cases. J Bone Joint Surg Am 1999; 81:844-7. [PMID: 10391549 DOI: 10.2106/00004623-199906000-00011] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
20
|
|
21
|
Abstract
The biologic response to polyethylene particulate debris generated from metal-on-polyethylene bearing surfaces is thought to be largely responsible for periprosthetic osteolysis and aseptic loosening in total joint arthroplasty. As a result, there has been an interest in developing polyethylene with improved wear characteristics, as well as a renewed interest in alternative bearing surfaces for total joint arthroplasty, including ceramic-polyethylene, metal-metal, and ceramic-ceramic articulations. These alternative surfaces have demonstrated less friction and lower wear rates than metal-on-polyethylene bearing surfaces in both clinical and laboratory experiments. Clinical results, although only short- to mid-term, have been encouraging. Alternative bearing surfaces, with lower wear rates and less particulate debris formation, may have the potential to improve total joint arthroplasty survivorship by decreasing periprosthetic osteolysis, especially in younger, high-demand patients.
Collapse
|
22
|
Hard bearing surfaces in total hip arthroplasty. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 1998; 27:283-92. [PMID: 9586727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Periprosthetic osteolysis and aseptic loosening are serious problems affecting the outcome of total joint replacement. Polyethylene particulate debris generated from metal-on-polyethylene bearing surfaces and the resulting biologic response to this debris are thought to be largely responsible. As a result, there has been a renewal of interest in hard bearing surfaces for total joint arthroplasty, including both metal-on-metal and ceramic-on-ceramic components. The new-generation all-ceramic and all-metal prostheses have demonstrated, both clinically and in the laboratory, lower friction and wear rates than metal-on-polyethylene bearing surfaces. Theoretically, lower wear rates result in less particulate debris and decreased inflammatory response. Despite excellent tribologic (lubrication, friction, wear) properties, metal-on-metal bearings raise associated issues of metal sensitivity and toxicity. For ceramic-on-ceramic bearing surfaces, issues of ceramic quality and the possibility of brittle fracture must be considered.
Collapse
|
23
|
Abstract
OBJECTIVES (a) To develop a reliable and reproducible system for distraction osteogenesis in the rat to establish a model for future investigations of bone repair and regeneration. (b) To describe and characterize the histological events in distraction osteogenesis in the rat and to determine whether cartilage development is a normal component of the process. STUDY DESIGN Species-specific, longitudinal time study. METHODS Twenty rats underwent production of a middiaphyseal femoral osteotomy and application of a monolateral external fixator specifically designed for distraction. Animals were divided into five groups based on the time and extent of lengthening. RESULTS During distraction, gap tissue showed collagen bundles and fibroblasts that were oriented longitudinally to the direction of the distraction force. Woven bone appeared to be laid down on these collagen scaffolds, and the newly formed vascular sinuses appeared to be the sites from which bone formation was initiated within the distraction gap. All groups undergoing active distraction showed intramembranous ossification in the distraction gap and endochondral ossification peripherally. However, when distraction was discontinued, endochondral ossification was observed in the gap. CONCLUSION Distraction produces an environment in the distraction gap that suppresses the formation of cartilage. The formation of cartilage by injured periosteum, however, is obligatory and does not appear to be influenced by distraction. Bone formation within the distraction gap occurs where angiogenesis develops.
Collapse
|