1
|
Patients' Perceptions and Attitudes to the Use of Artificial Intelligence in Breast Cancer Diagnosis: A Narrative Review. Life (Basel) 2024; 14:454. [PMID: 38672725 PMCID: PMC11051490 DOI: 10.3390/life14040454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 03/26/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
Breast cancer remains the most prevalent cancer among women worldwide, necessitating advancements in diagnostic methods. The integration of artificial intelligence (AI) into mammography has shown promise in enhancing diagnostic accuracy. However, understanding patient perspectives, particularly considering the psychological impact of breast cancer diagnoses, is crucial. This narrative review synthesizes literature from 2000 to 2023 to examine breast cancer patients' attitudes towards AI in breast imaging, focusing on trust, acceptance, and demographic influences on these views. Methodologically, we employed a systematic literature search across databases such as PubMed, Embase, Medline, and Scopus, selecting studies that provided insights into patients' perceptions of AI in diagnostics. Our review included a sample of seven key studies after rigorous screening, reflecting varied patient trust and acceptance levels towards AI. Overall, we found a clear preference among patients for AI to augment rather than replace the diagnostic process, emphasizing the necessity of radiologists' expertise in conjunction with AI to enhance decision-making accuracy. This paper highlights the importance of aligning AI implementation in clinical settings with patient needs and expectations, emphasizing the need for human interaction in healthcare. Our findings advocate for a model where AI augments the diagnostic process, underlining the necessity for educational efforts to mitigate concerns and enhance patient trust in AI-enhanced diagnostics.
Collapse
|
2
|
Contrast-enhanced mammography BI-RADS: a case-based approach to radiology reporting. Insights Imaging 2024; 15:37. [PMID: 38332410 PMCID: PMC10853105 DOI: 10.1186/s13244-024-01612-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 12/28/2023] [Indexed: 02/10/2024] Open
Abstract
Contrast-enhanced mammography (CEM) is a relatively recent diagnostic technique increasingly being utilized in clinical practice. Until recently, there was a lack of standardized reporting for CEM findings. However, this has changed with the publication of a supplement in the Breast Imaging Reporting and Data System (BI-RADS). A comprehensive understanding of CEM is essential for further enhancing its role in both screening and managing patients with breast malignancies. CEM can also be beneficial for problem-solving, improving the management of uncertain breast findings. Practitioners in this field should become more cognizant of how and when to employ this technique and interpret the various CEM findings. This paper aims to outline the key findings in the updated version of the BI-RADS specifically dedicated to CEM. Additionally, it will present some clinical cases commonly encountered in clinical practice.Critical relevance statement Standardized reporting and a thorough understanding of CEM findings are pivotal for advancing the role of CEM in screening and managing breast cancer patients. This standardization contributes significantly to integrating CEM as an essential component of daily clinical practice.Key points • A complete knowledge and understanding of the findings outlined in the new BI-RADS CEM are necessary for accurate reporting.• BI-RADS CEM supplement is intuitive and practical to use.• Standardization of the CEM findings enables more accurate patient management.
Collapse
|
3
|
Breast Imaging Reporting and Data System and Contrast Enhancement Mammography: Lesion Conspicuity Likelihood of Malignancy and Relationship With Breast Tumor Receptor Status. Acad Radiol 2023; 30:2243-2251. [PMID: 36898907 DOI: 10.1016/j.acra.2023.02.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 01/30/2023] [Accepted: 02/07/2023] [Indexed: 03/10/2023]
Abstract
RATIONALE AND OBJECTIVES The new version of the Contrast Enhanced Mammography (CEM) Breast imaging Reporting and Data System (BIRADs) encourages investigations of a new enhancement descriptor: "Lesion Conspicuity" (LC). The study aims to assess the diagnostic performance and the relationship with the receptor profile of this new enhancement descriptor. MATERIALS AND METHODS Three hundred twenty-five patients with 381 breast lesions who underwent CEM before histological assessmentwere selected. Four radiologists, blinded to each other, categorized LC into the following levels: absent, low, moderate, and high. Considering moderate and high evaluations as predictive of malignancy, the diagnostic performance of CEM was calculated using histological results of the biopsy as the gold standard. The association between LC values and the receptor profile of the neoplasms was also evaluated. RESULTS The median age at the CEM examination was 50 years (IQR: 45-59). Considering the value of LC of the most experienced radiologist with the interpretation of Low Energy images (LE), we obtained a sensitivity (SE) of 91.9% (95% CI: 88.6%-95.2%) and a specificity (SP) of 67.2% (95% CI: 58.9%-75.5%). An association between "high" lesion conspicuity with ER/PgR not expressed (p = 0.025), with Ki-67>20% (p = 0.033), and with Grading G3 (p = 0.020) was observed. CONCLUSION The new feature of enhancement, "Lesion Conspicuity", demonstrated satisfactory performance in predicting the malignancy of lesions and significant correlation with the receptor profile of malignant breast neoplasms.
Collapse
|
4
|
An Unenhanced Breast MRI Protocol Based on Diffusion-Weighted Imaging: A Retrospective Single-Center Study on High-Risk Population for Breast Cancer. Diagnostics (Basel) 2023; 13:1996. [PMID: 37370892 DOI: 10.3390/diagnostics13121996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 05/10/2023] [Accepted: 06/01/2023] [Indexed: 06/29/2023] Open
Abstract
PURPOSE This study aimed to investigate the use of contrast-free magnetic resonance imaging (MRI) as an innovative screening method for detecting breast cancer in high-risk asymptomatic women. Specifically, the researchers evaluated the diagnostic performance of diffusion-weighted imaging (DWI) in this population. METHODS MR images from asymptomatic women, carriers of a germline mutation in either the BRCA1 or BRCA2 gene, collected in a single center from January 2019 to December 2021 were retrospectively evaluated. A radiologist with experience in breast imaging (R1) and a radiology resident (R2) independently evaluated DWI/ADC maps and, in case of doubts, T2-WI. The standard of reference was the pathological diagnosis through biopsy or surgery, or ≥1 year of clinical and radiological follow-up. Diagnostic performances were calculated for both readers with a 95% confidence interval (CI). The agreement was assessed using Cohen's kappa (κ) statistics. RESULTS Out of 313 women, 145 women were included (49.5 ± 12 years), totaling 344 breast MRIs with DWI/ADC maps. The per-exam cancer prevalence was 11/344 (3.2%). The sensitivity was 8/11 (73%; 95% CI: 46-99%) for R1 and 7/11 (64%; 95% CI: 35-92%) for R2. The specificity was 301/333 (90%; 95% CI: 87-94%) for both readers. The diagnostic accuracy was 90% for both readers. R1 recalled 40/344 exams (11.6%) and R2 recalled 39/344 exams (11.3%). Inter-reader reproducibility between readers was in moderate agreement (κ = 0.43). CONCLUSIONS In female carriers of a BRCA1/2 mutation, breast DWI supplemented with T2-WI allowed breast cancer detection with high sensitivity and specificity by a radiologist with extensive experience in breast imaging, which is comparable to other screening tests. The findings suggest that DWI and T2-WI have the potential to serve as a stand-alone method for unenhanced breast MRI screening in a selected population, opening up new perspectives for prospective trials.
Collapse
|
5
|
History of Mammography: Analysis of Breast Imaging Diagnostic Achievements over the Last Century. Healthcare (Basel) 2023; 11:healthcare11111596. [PMID: 37297735 DOI: 10.3390/healthcare11111596] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/23/2023] [Accepted: 05/27/2023] [Indexed: 06/12/2023] Open
Abstract
Breast cancer is the most common forms of cancer and a leading cause of mortality in women. Early and correct diagnosis is, therefore, essential to save lives. The development of diagnostic imaging applied to the breast has been impressive in recent years and the most used diagnostic test in the world is mammography, a low-dose X-ray technique used for imaging the breast. In the first half of the 20th century, the diagnosis was in practice only clinical, with consequent diagnostic delay and an unfavorable prognosis in the short term. The rise of organized mammography screening has led to a remarkable reduction in mortality through the early detection of breast malignancies. This historical review aims to offer a complete panorama of the development of mammography and breast imaging during the last century. Through this study, we want to understand the foundations of the pillar of radiology applied to the breast through to the most modern applications such as contrast-enhanced mammography (CEM), artificial intelligence, and radiomics. Understanding the history of the development of diagnostic imaging applied to the breast can help us understand how to better direct our efforts toward an increasingly personalized and effective diagnostic approach. The ultimate goal of imaging applied to the detection of breast malignancies should be to reduce mortality from this type of disease as much as possible. With this paper, we want to provide detailed documentation of the main steps in the evolution of breast imaging for the diagnosis of breast neoplasms; we also want to open up new scenarios where the possible current and future applications of imaging are aimed at being more precise and personalized.
Collapse
|
6
|
How Radiomics Can Improve Breast Cancer Diagnosis and Treatment. J Clin Med 2023; 12:jcm12041372. [PMID: 36835908 PMCID: PMC9963325 DOI: 10.3390/jcm12041372] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/04/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023] Open
Abstract
Recent technological advances in the field of artificial intelligence hold promise in addressing medical challenges in breast cancer care, such as early diagnosis, cancer subtype determination and molecular profiling, prediction of lymph node metastases, and prognostication of treatment response and probability of recurrence. Radiomics is a quantitative approach to medical imaging, which aims to enhance the existing data available to clinicians by means of advanced mathematical analysis using artificial intelligence. Various published studies from different fields in imaging have highlighted the potential of radiomics to enhance clinical decision making. In this review, we describe the evolution of AI in breast imaging and its frontiers, focusing on handcrafted and deep learning radiomics. We present a typical workflow of a radiomics analysis and a practical "how-to" guide. Finally, we summarize the methodology and implementation of radiomics in breast cancer, based on the most recent scientific literature to help researchers and clinicians gain fundamental knowledge of this emerging technology. Alongside this, we discuss the current limitations of radiomics and challenges of integration into clinical practice with conceptual consistency, data curation, technical reproducibility, adequate accuracy, and clinical translation. The incorporation of radiomics with clinical, histopathological, and genomic information will enable physicians to move forward to a higher level of personalized management of patients with breast cancer.
Collapse
|
7
|
Radiomic Features Applied to Contrast Enhancement Spectral Mammography: Possibility to Predict Breast Cancer Molecular Subtypes in a Non-Invasive Manner. Int J Mol Sci 2022; 23:ijms232315322. [PMID: 36499648 PMCID: PMC9740943 DOI: 10.3390/ijms232315322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 11/28/2022] [Accepted: 12/01/2022] [Indexed: 12/12/2022] Open
Abstract
We aimed to investigate the association between the radiomic features of contrast-enhanced spectral mammography (CESM) images and a specific receptor pattern of breast neoplasms. In this single-center retrospective study, we selected patients with neoplastic breast lesions who underwent CESM before a biopsy and surgical assessment between January 2013 and February 2022. Radiomic analysis was performed on regions of interest selected from recombined CESM images. The association between the features and each evaluated endpoint (ER, PR, Ki-67, HER2+, triple negative, G2-G3 expressions) was investigated through univariate logistic regression. Among the significant and highly correlated radiomic features, we selected only the one most associated with the endpoint. From a group of 321 patients, we enrolled 205 malignant breast lesions. The median age at the exam was 50 years (interquartile range (IQR) 45-58). NGLDM_Contrast was the only feature that was positively associated with both ER and PR expression (p-values = 0.01). NGLDM_Coarseness was negatively associated with Ki-67 expression (p-value = 0.02). Five features SHAPE Volume(mL), SHAPE_Volume(vx), GLRLM_RLNU, NGLDM_Busyness and GLZLM_GLNU were all positively and significantly associated with HER2+; however, all of them were highly correlated. Radiomic features of CESM images could be helpful to predict particular molecular subtypes before a biopsy.
Collapse
|
8
|
Women’s perceptions and attitudes to the use of AI in breast cancer screening: a survey in a cancer referral centre. Br J Radiol 2022; 96:20220569. [DOI: 10.1259/bjr.20220569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Objective: Although breast cancer screening can benefit from Artificial Intelligence (AI), it is still unknown whether, to which extent or under which conditions, the use of AI is going to be accepted by the general population. The aim of our study is to evaluate what the females who are eligible for breast cancer screening know about AI and how they perceive such innovation. Methods: We used a prospective survey consisting of a 11-multiple-choice questionnaire evaluating statistical associations with Chi-Square-test or Fisher-exact-test. Multinomial-logistic-regression was performed on items with more than two response categories. Odds ratio (OR) with 95% CI were computed to estimate the probability of a specific response according to patient’s characteristics. Results: In the 800 analysed questionnaires, 51% of respondents confirmed to have knowledge of AI. Of these, 88% expressed a positive opinion about its use in medicine. Non-Italian respondents were associated with the belief of having a deep awareness about AI more often than Italian respondents (OR = 1.91;95% CI[1.10–3.33]). Higher education level was associated with better opinions on the use of AI in medicine (OR = 4.69;95% CI[1.36–16.12]). According to 94% of respondents, the radiologists should always produce their own report on mammograms, whilst 77% agreed that AI should be used as a second reader. Most respondents (52%) considered that both the software developer and the radiologist should be held accountable for AI errors. Conclusions: Most of the females undergoing screening in our Institute approve the introduction of AI, although only as a support to radiologist, and not in substitution thereof. Yet, accountability in case of AI errors is still unsolved. advances in knowledge: This survey may be considered as a pilot-study for the development of large-scale studies to understand females’s demands and concerns about AI applications in breast cancer screening.
Collapse
|
9
|
Mammography in 2022, from Computer-Aided Detection to Artificial Intelligence Applications. CLIN EXP OBSTET GYN 2022. [DOI: 10.31083/j.ceog4911237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
10
|
A Score to Predict the Malignancy of a Breast Lesion Based on Different Contrast Enhancement Patterns in Contrast-Enhanced Spectral Mammography. Cancers (Basel) 2022; 14:cancers14174337. [PMID: 36077871 PMCID: PMC9455061 DOI: 10.3390/cancers14174337] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/29/2022] [Accepted: 09/02/2022] [Indexed: 11/17/2022] Open
Abstract
Background: To create a predictive score of malignancy of a breast lesion based on the main contrast enhancement features ascertained by contrast-enhanced spectral mammography (CESM). Methods: In this single-centre prospective study, patients with suspicious breast lesions (BIRADS > 3) were enrolled between January 2013 and February 2022. All participants underwent CESM prior to breast biopsy, and eventually surgery. A radiologist with 20 years’ experience in breast imaging evaluated the presence or absence of enhancement and the following enhancement descriptors: intensity, pattern, margin, and ground glass. A score of 0 or 1 was given for each descriptor, depending on whether the enhancement characteristic was predictive of benignity or malignancy (both in situ and invasive). Then, an overall enhancement score ranging from 0 to 4 was obtained. The histological results were considered the gold standard in the evaluation of the relationship between enhancement patterns and malignancy. Results: A total of 321 women (median age: 51 years; range: 22−83) with 377 suspicious breast lesions were evaluated. Two hundred forty-nine lesions (66%) have malignant histological results (217 invasive and 32 in situ). Considering an overall enhancement score ≥ 2 as predictive of malignancy, we obtain an overall sensitivity of 92.4%; specificity of 89.8%; positive predictive value of 94.7%; and negative predictive value of 85.8%. Conclusions: Our proposed predictive score on the enhancement descriptors of CESM to predict the malignancy of a breast lesion shows excellent results and can help in early breast cancer diagnosis and in avoiding unnecessary biopsies.
Collapse
|
11
|
Evaluation of computer-aided diagnosis in breast ultrasonography: Improvement in diagnostic performance of inexperienced radiologists. Clin Imaging 2021; 82:150-155. [PMID: 34826773 DOI: 10.1016/j.clinimag.2021.11.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 09/11/2021] [Accepted: 11/07/2021] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate if a computer-aided diagnosis (CAD) system on ultrasound (US) can improve the diagnostic performance of inexperienced radiologists. METHODS We collected ultrasound images of 256 breast lesions taken between March and May 2020. We asked two experienced and two inexperienced radiologists to retrospectively review the US features of each breast lesion according to the Breast Imaging Reporting and Data System (BI-RADS) categories. A CAD examination with S-Detect™ software (Samsung Healthcare, Seoul, South Korea) was conducted retrospectively by another uninvolved radiologist blinded to the BIRADS values previously attributed to the lesions. Diagnostic performances of experienced and inexperienced radiologists and CAD were compared and the inter-observer agreement among radiologists was calculated. RESULTS The diagnostic performance of the experienced group in terms of sensitivity was significantly higher than CAD (p < 0.001). Conversely, the diagnostic performance of inexperienced group in terms of both sensitivity and specificity was significantly lower than CAD (p < 0.001). We obtained an excellent agreement in the evaluation of the lesions among the two expert radiologists (Kappa coefficient: 88.7%), and among the two non-expert radiologists (Kappa coefficient: 84.9%). CONCLUSION The US CAD system is a useful additional tool to improve the diagnostic performance of the inexperienced radiologists, eventually reducing the number of unnecessary biopsies. Moreover, it is a valid second opinion in case of experienced radiologists.
Collapse
|
12
|
Abstract
Breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) is a rare and newly recognized subtype of T cell Non-Hodgkin Lymphoma (NHLs) associated with breast implants.The mechanism involved in the development of this kind of lymphoma is still uncertain.BIA-ALCL is generally an indolent disease localized to the breast implant and its capsule and effectively treated with capsulectomy alone without chemotherapy.Clinically, BIA-ALCL may typically present a sudden-onset breast-swelling secondary to periimplant effusion. The minority of BIA-ALCL patients present a more aggressive mass-forming subtype, for which systemic therapy is mandatory.Despite the number of cases has recently increased, BIA-ALCL remains a rare disease described mainly in several case reports and small case series.Breast imaging, including mammography, ultrasound and breast MRI are routinely used in the screening of breast cancer; however, guidelines for the imaging and pathological diagnosis of this disease have only recently been proposed and included in the 2019 National Comprehensive Cancer Network (NCCN) consensus guidelines for BIA-ALCL.The main purpose of this pictorial is to illustrate the MRI signs of BIA-ALCL and correlate them with the corresponding pathology features in order to improve the knowledge of the principals MRI features of this type of lymphoma.
Collapse
|
13
|
COVID-19 and breast fine needle aspiration cytology method: What should we change? Cytopathology 2021; 32:312-317. [PMID: 33606300 PMCID: PMC8014188 DOI: 10.1111/cyt.12959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 12/28/2020] [Accepted: 01/13/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Air-dried slide preparation for fine needle aspiration cytology procedures is currently considered unsafe because of the risk of infectious aerosols of coronavirus 19. This study compares the safety and accuracy of two different protocols, one with and one without air-dried slides. METHODS Starting from 3 March 2020, we discontinued the use of air-dried slides during breast fine needle aspiration procedures. We selected cases collected during two periods: 2 months before and 2 months after 3 March. In both groups, the number of procedures was recorded together with the distribution of the diagnostic categories and the concordance between cytological and histological results on surgical specimens for lesions suggestive of malignancy, using the chi-squared test. RESULTS Of the 100 procedures performed during the pre-COVID-19 period, 55% were negative (C2), 3% were non-diagnostic (C1) and 40% were positive (C4 or C5). Of the 75 procedures obtained during the COVID-19 period, 44% were negative (C2), 2.7% were non-diagnostic (C1) and 52% were positive (C4 or C5). Despite the use of a new protocol during the COVID-19 period, we observed concordance between cytological and histological results for lesions suggestive of malignancy. There was no statistically significant difference concerning the distribution of the diagnostic categories in the two groups. CONCLUSIONS Taking into account the slightly lower number of procedures being analysed during the COVID-19 period, the introduction of a new protocol that does not include air-dried slides is safe and reliable.
Collapse
|
14
|
Wireless ultrasound-guided vacuum-assisted breast biopsy: Experience in clinical practice at European Institute of Oncology. Breast J 2021; 27:514-520. [PMID: 33677844 DOI: 10.1111/tbj.14216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 02/19/2021] [Accepted: 02/22/2021] [Indexed: 01/04/2023]
Abstract
In the last few years, ultrasound-guided vacuum-assisted breast biopsy (US-VABB) has replaced surgical biopsy due to higher diagnostic accuracy and lower patient discomfort, and, at present, an even greater possibility is represented by the new wireless ultrasound-guided VAB device (Wi-UVAB). The purpose of our study is to determine the diagnostic accuracy of this new device in a sizeable representative number of patients. From January 2014 to June 2018, 168 biopsies were performed in our institution using the new Wi-UVAB device. We analyzed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of biopsies obtained with the new device using surgical results as reference point, following patients for at least one year. In our cohort, we obtained a complete sensitivity of 97.5%, an absolute sensitivity of 94.3%, a complete specificity of 98%, and an absolute specificity of 98%. The positive predictive value of the procedure was 97.5% while the negative predictive value was 98%. The diagnostic accuracy was 98%. The Wi-UVAB is a safe procedure with high diagnostic accuracy, comparable to that of the traditional vacuum-assisted breast biopsy and even higher than that of core needle biopsy (CNB). Moreover, the Wi-UVAB is easy to use and shows low costs as core needle biopsy (CNB).
Collapse
|
15
|
How we provided appropriate breast imaging practices in the epicentre of the COVID-19 outbreak in Italy. Br J Radiol 2020; 93:20200679. [PMID: 32877209 PMCID: PMC7548363 DOI: 10.1259/bjr.20200679] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Italy has one of the highest COVID-19 clinical burdens in the world and Lombardy region accounts for more than half of the deaths of the country. Since COVID-19 is a novel disease, early impactful decisions are often based on experience of referral centres. We report the re-organisation which our institute (IEO, European Institute of Oncology), a cancer referral centre in Lombardy, went through to make our breast-imaging division pandemic-proof. Using personal-protective-equipment and innovative protocols, we provided essential breast-imaging procedures during COVID-19 pandemic without compromising cancer outcomes. The emergency management and infection-control-measures implemented in our division protected both the patients and the staff, making this experience useful for other radiology departments dealing with the pandemic.
Collapse
|
16
|
Clinical performance of contrast-enhanced spectral mammography in pre-surgical evaluation of breast malignant lesions in dense breasts: a single center study. Breast Cancer Res Treat 2020; 184:723-731. [PMID: 32860166 PMCID: PMC7655556 DOI: 10.1007/s10549-020-05881-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Accepted: 08/13/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE To compare the efficacy of contrast-enhanced spectral mammography, with ultrasound, full field digital mammography and magnetic resonance imaging in detection and size estimation of histologically proven breast tumors. METHODS This open-label, single center, prospective study, included 160 dense breast women with at least one suspicious mammary lesion evaluated by ultrasound, full field digital mammography and magnetic resonance imaging in whom a mammary tumor was histologically proven after surgery performed at the European Institute of Oncology between January 2013 and December 2015. Following the complete diagnostic procedure, the patients were further investigated by contrast-enhanced spectral mammography prior to surgery. RESULTS Overall, the detection rate of malignant breast lesions (in situ and invasive) was 93.8% (165/176) for contrast-enhanced spectral mammography, 94.4% (168/178) for ultrasound, 85.5 (147/172) for full field digital mammography and 97.7% (173/177) for magnetic resonance imaging. Radiological measurements were concordant with the post-surgical pathological measurements of the invasive tumor (i.e., within 5 mm) in: 64.6% for contrast-enhanced spectral mammography, 62.0% for ultrasound, 45.2% for full field digital mammography (p < 0.0001) and 69.9% for magnetic resonance imaging (p = 0.28); underestimated in: 17.4% for contrast-enhanced spectral mammography, 19.6% for ultrasound, 24.2% for full field digital mammography (p = 0.03) and 6.7% for magnetic resonance imaging (p = 0.0005); and overestimated in: 16.2% for contrast-enhanced spectral mammography, 16.6% for ultrasound, 16.6% for full field digital mammography and 22.7% for magnetic resonance imaging (p = 0.02). CONCLUSIONS Our data suggest that contrast-enhanced spectral mammography improves on full field digital mammography and is comparable to ultrasound and magnetic resonance imaging in terms of detection sensitivity and size estimation of malignant lesions in dense breasts.
Collapse
|
17
|
Abstract
The three-dimensional automated breast ultrasound system (3D ABUS) is a new device which represents a huge innovation in the breast ultrasound field, with several application scenarios of great interest. ABUS's aim is to solve some of the main defects of traditional ultrasound, such as lack of standardization, high level of skill non-reproducibility, small field of view and high commitment of physician time. ABUS has proven to be an excellent non-ionising alternative to other supplemental screening options for women with dense breast tissue; also, it has appeared to be very promising in daily clinical practice. The purpose of this paper is to present a summary of current applications of ABUS, focusing on clinical applications and future perspectives as ABUS is particularly promising for studies involving artificial intelligence, radiomics and evaluation of breast molecular subtypes.
Collapse
|
18
|
Metal-cellulose catalytic systems for biodiesel preparation and reductive stabilization. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.molcata.2016.01.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
19
|
Safety and efficacy of HRT and low-dose tamoxifen in a phase II trial (HOT): Analysis of mammographic density and endometrial thickness. J Clin Oncol 2011. [DOI: 10.1200/jco.2011.29.15_suppl.1527] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
20
|
Sensitivity of imaging for multifocal-multicentric breast carcinoma. BMC Cancer 2008; 8:275. [PMID: 18826585 PMCID: PMC2576336 DOI: 10.1186/1471-2407-8-275] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2007] [Accepted: 09/30/2008] [Indexed: 11/25/2022] Open
Abstract
Background This retrospective study aims to determine: 1) the sensitivity of preoperative mammography (Mx) and ultrasound (US), and re-reviewed Mx to detect multifocal multicentric breast carcinoma (MMBC), defined by pathology on surgical specimens, and 2) to analyze the characteristics of both detected and undetected foci on Mx and US. Methods Three experienced breast radiologists re-reviewed, independently, digital mammography of 97 women with MMBC pathologically diagnosed on surgical specimens. The radiologists were informed of all neoplastic foci, and blinded to the original mammograms and US reports. With regards to Mx, they considered the breast density, number of foci, the Mx characteristics of the lesions and their BI-RADS classification. For US, they considered size of the lesions, BI-RADS classification and US pattern and lesion characteristics. According to the histological size, the lesions were classified as: index cancer, 2nd lesion, 3rd lesion, and 4th lesion. Any pathologically identified malignant foci not previously described in the original imaging reports, were defined as undetected or missed lesions. Sensitivity was calculated for Mx, US and re-reviewed Mx for detecting the presence of the index cancer as well as additional satellite lesions. Results Pathological examination revealed 13 multifocal and 84 multicentric cancers with a total of 303 malignant foci (282 invasive and 21 non invasive). Original Mx and US reports had an overall sensitivity of 45.5% and 52.9%, respectively. Mx detected 83/97 index cancers with a sensitivity of 85.6%. The number of lesions undetected by original Mx was 165/303. The Mx pattern of breasts with undetected lesions were: fatty in 3 (1.8%); scattered fibroglandular density in 40 (24.3%), heterogeneously dense in 91 (55.1%) and dense in 31 (18.8%) cases. In breasts with an almost entirely fatty pattern, Mx sensitivity was 100%, while in fibroglandular or dense pattern it was reduced to 45.5%. Re-reviewed Mx detected only 3 additional lesions. The sensitivity of Mx was affected by the presence of dense breast tissue which obscured lesions or by an incorrect interpretation of suspicious findings. US detected 73/80 index cancers (sensitivity of 91.2%), US missed 117 malignant foci with a mean tumor diameter of 6.5 mm; the sensitivity was 52.9% Undetected lesions by US were those smallest in size and present in fatty breast or in the presence of microcalcifications without a visible mass. US sensitivity was affected by the presence of fatty tissue or by the extent of calcification. Conclusion Mx missed MMBC malignant foci more often in dense or fibroglandular breasts. US missed small lesions in mainly fatty breasts or when there were only microcalcifications. The combined sensitivity of both techniques to assess MMBC was 58%. We suggest larger studies on multimodality imaging.
Collapse
|
21
|
Analogic versus digital mammographic examination a radiological study of mammary microcalcifications on 52 surgical samples. LA RADIOLOGIA MEDICA 2003; 106:297-304. [PMID: 14612821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/27/2023]
Abstract
PURPOSE Digital mammography is known to have lower spatial resolution compared to conventional analogic mammography. The aim of this study was to evaluate whether this physical feature could compromise the perception of microcalcifications in radiological findings. MATERIALS AND METHODS Fifty-two surgical samples of non-palpable breast lesions with microcalcifications were imaged using both techniques. The images were examined by four different radiologists. Data processing was limited to comparing the number of microcalcifications found on the conventional and digital images, in both standard and magnified modality. The cases were classified into 3 groups according to the number of calcifications demonstrated in the surgical sample: less than 10, 10 to 30, and more than 30. The differences in the count of microcalcifications with the two acquisition modalities were evaluated with the Kappa test. In order to compare the differences we synthesised by percentage those cases exhibiting a larger or lesser number of calcifications. RESULTS The Kappa test was 0.546 in standard analogic vs standard digital, 0.582 in magnified analogic vs magnified digital, 0.828 in standard analogic vs magnified analogic and 0.492 in standard digital vs magnified digital. The most significant results were observed on comparing the magnifications produced with the two modalities: in 25% of cases, digital magnification detected more calcifications than did traditional magnification. The number of cases where standard digital images allowed the detection of more calcifications than standard analogic images was significant, although less important (17.8%). CONCLUSIONS The study was able to provide data that confirm the overall equivalence of the two techniques, as far as subtle mammographic findings (such as microcalcifications) are concerned. In particular, as applied to the series we examined, there is a cautious advantage in favour of the digital technique. More clinical studies, on larger series, will be necessary for a further and more thorough comparison of the two techniques, so that the results might be consistently useful in clinical practice.
Collapse
|
22
|
Human natriuretic factor in cirrhotic patients undergoing orthotopic liver transplantation. Transpl Int 1995; 8:51-4. [PMID: 7888052 DOI: 10.1007/bf00366711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
We measured the plasma levels of atrial natriuretic factor (ANF) during orthotopic liver transplantation (OLT) in eight adult patients with cirrhosis and ascites. The aim of this study was to determine whether significant differences in ANF concentration may be detected during the individual phases of OLT and to correlate these changes with hemodynamics. In each patient a hemodynamic assessment was achieved using a Swan-Ganz fiber optic catheter for continuous monitoring of cardiac output (CO), systemic vascular resistance index (SVRI), right filling pressure as assessed by central venous pressure (CVP), and left filling pressure by means of pulmonary arterial wedge pressure (PAWP). During reperfusion a clear-cut increase in ANF values was observed (P < 0.05). Concurrently, an increase in CVP (P < 0.05) and a decrease in SVRI were observed without any significant increase in diuresis. These data suggest that ANF might play a role in the development of the reperfusion syndrome.
Collapse
|
23
|
[Infantile nephrocalcinosis. Description of a case]. LA RADIOLOGIA MEDICA 1993; 85:682-4. [PMID: 8327777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
24
|
Right ejection fraction and maximum elasticity are sensitive measurements of right ventricular function during liver transplantation. Transplant Proc 1993; 25:1842-4. [PMID: 8470194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
25
|
[Intraoperative changes in blood lactate during orthotopic transplantation of the liver]. Minerva Anestesiol 1991; 57:698-9. [PMID: 1798541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
26
|
[The non-functioning liver transplant: its prediction by monitoring total oxygen consumption]. Minerva Anestesiol 1991; 57:692-3. [PMID: 1798538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
27
|
[Differences in potential and content of the mucus in the stomach of the rat with avitaminosis A]. BOLLETTINO DELLA SOCIETA ITALIANA DI BIOLOGIA SPERIMENTALE 1990; 66:543-50. [PMID: 2257121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Vitamin A (vit. A) acts in the synthesis of glycoproteins and in cell surface phenomena of epithelia. Since the glycoproteins of gastric mucus and the integrity of gastric cell membranes are components of gastric barrier (GB), vit. A could play a role in GB. Five groups of rats were used: I) rats fed on vit. A deficient diet; II) rats pair-fed plus a daily oral dose of 45 micrograms vit. A; III) normal rats; IV) rats recovered from avitaminosis A (avit. A) after 20 days of daily oral dose of 300 micrograms vit. A; V) rats pair-fed plus a daily oral dose of 45 micrograms vit. A. We measured: 1) transparietal gastric potential difference (PD) in vivo (by means of agar-KCl electrodes); 2) mucus (by binding of Alcian blue): in gastric mucosa; adherent to gastric mucosa; in gastric lumen; 3) dry weight of the stomach. Avit. A induced: i) a decrease of PD and mucus in mucosa and lumen; ii) an increase of mucus adherent to mucosa; iii) an increase of the percentage of dry weight on wet weight. All parameters were normal after recovery from avit. A. Results suggest that avit. A could reduce either mucus synthesis or its erosion. Moreover avit. A might modify mucus structure and sterical configuration of mucosal cells. The alteration of mucosal cell membranes could decrease PD. In conclusion the modifications of some components of rat GB seem specifically caused by avit. A and suggest a protective role of vit. A.
Collapse
|
28
|
|
29
|
|