1
|
Aramendía-Vidaurreta V, Solís-Barquero SM, Vidorreta M, Ezponda A, Echeverria-Chasco R, Bastarrika G, Fernández-Seara MA. Comparison of Myocardial Blood Flow Quantification Models for Double ECG Gating Arterial Spin Labeling MRI: Reproducibility Assessment. J Magn Reson Imaging 2024. [PMID: 38206090 DOI: 10.1002/jmri.29220] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 12/20/2023] [Accepted: 12/20/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND Arterial spin labeling (ASL) allows non-invasive quantification of myocardial blood flow (MBF). Double-ECG gating (DG) ASL is more robust to heart rate variability than single-ECG gating (SG), but its reproducibility requires further investigation. Moreover, the existence of multiple quantification models hinders its application. Frequency-offset-corrected-inversion (FOCI) pulses provide sharper edge profiles than hyperbolic-secant (HS), which could benefit myocardial ASL. PURPOSE To assess the performance of MBF quantification models for DG compared to SG ASL, to evaluate their reproducibility and to compare the effects of HS and FOCI pulses. STUDY TYPE Prospective. SUBJECTS Sixteen subjects (27 ± 8 years). FIELD STRENGTH/SEQUENCE 1.5 T/DG and SG flow-sensitive alternating inversion recovery ASL. ASSESSMENT Three models for DG MBF quantification were compared using Monte Carlo simulations and in vivo experiments. Two models used a fitting approach (one using only a single label and control image pair per fit, the other using all available image pairs), while the third model used a T1 correction approach. Slice profile simulations were conducted for HS and FOCI pulses with varying B0 and B1. Temporal signal-to-noise ratio (tSNR) was computed for different acquisition/quantification strategies and inversion pulses. The number of images that minimized MBF error was investigated in the model with highest tSNR. Intra and intersession reproducibility were assessed in 10 subjects. STATISTICAL TESTS Within-subject coefficient of variation, analysis of variance. P-value <0.05 was considered significant. RESULTS MBF was not different across acquisition/quantification strategies (P = 0.27) nor pulses (P = 0.9). DG MBF quantification models exhibited significantly higher tSNR and superior reproducibility, particularly for the fitting model using multiple images (tSNR was 3.46 ± 2.18 in vivo and 3.32 ± 1.16 in simulations, respectively; wsCV = 16%). Reducing the number of ASL pairs to 13/15 did not increase MBF error (minimum = 0.22 mL/g/min). DATA CONCLUSION Reproducibility of MBF was better for DG than SG acquisitions, especially when employing a fitting model. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 1.
Collapse
|
2
|
Calvo-Imirizaldu M, Aramendía-Vidaurreta V, Sánchez-Albardíaz C, Vidorreta M, García de Eulate R, Domínguez Echávarri PD, Pfeuffer J, Bejarano Herruzo B, Gonzalez-Quarante LH, Martinez-Simon A, Fernández-Seara MA. Clinical utility of intraoperative arterial spin labeling for resection control in brain tumor surgery at 3 T. NMR IN BIOMEDICINE 2023:e4938. [PMID: 36967637 DOI: 10.1002/nbm.4938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 02/28/2023] [Accepted: 03/17/2023] [Indexed: 06/18/2023]
Abstract
Resection control in brain tumor surgery can be achieved in real time with intraoperative MRI (iMRI). Arterial spin labeling (ASL), a technique that measures cerebral blood flow (CBF) non-invasively without the use of intravenous contrast agents, can be performed intraoperatively, providing morpho-physiological information. This study aimed to evaluate the feasibility, image quality and potential to depict residual tumor of a pseudo-continuous ASL (PCASL) sequence at 3 T. Seventeen patients with brain tumors, primary (16) or metastatic (1), undergoing resection surgery with iMRI monitoring, were prospectively recruited (nine men, age 56 ± 16.6 years). A PCASL sequence with long labeling duration (3000 ms) and postlabeling delay (2000 ms) was added to the conventional protocol, which consisted of pre- and postcontrast 3D T1 -weighted (T1w) images, optional 3D-FLAIR, and diffusion. Three observers independently assessed the image quality (four-point scale) of PCASL-derived CBF maps. In those with diagnostic quality (Scores 2-4) they evaluated the presence of residual tumor using the conventional sequences first, and the CBF maps afterwards (three-point scale). Inter-observer agreement for image quality and the presence of residual tumor was assessed using Fleiss kappa statistics. The intraoperative CBF ratio of the surgical margins (i.e., perilesional CBF values normalized to contralateral gray matter CBF) was compared with preoperative CBF ratio within the tumor (Wilcoxon's test). Diagnostic ASL image quality was observed in 94.1% of patients (interobserver Fleiss κ = 0.76). PCASL showed additional foci suggestive of high-grade residual component in three patients, and a hyperperfused area extending outside the enhancing component in one patient. Interobserver agreement was almost perfect in the evaluation of residual tumor with the conventional sequences (Fleiss κ = 0.92) and substantial for PCASL (Fleiss κ = 0.80). No significant differences were found between pre and intraoperative CBF ratios (p = 0.578) in patients with residual tumor (n = 7). iMRI-PCASL perfusion is feasible at 3 T and is useful for the intraoperative assessment of residual tumor, providing in some cases additional information to the conventional sequences.
Collapse
|
3
|
Echeverria‐Chasco R, Martin‐Moreno PL, Garcia‐Fernandez N, Vidorreta M, Aramendia‐Vidaurreta V, Cano D, Villanueva A, Bastarrika G, Fernández‐Seara MA. Multiparametric renal magnetic resonance imaging: A reproducibility study in renal allografts with stable function. NMR IN BIOMEDICINE 2023; 36:e4832. [PMID: 36115029 PMCID: PMC10078573 DOI: 10.1002/nbm.4832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 09/13/2022] [Accepted: 09/15/2022] [Indexed: 06/15/2023]
Abstract
Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo-Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo-diffusion coefficient (D*), flowing fraction ( f ), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within-subject coefficient of variation, intraclass correlation coefficient, and Bland-Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for f , and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and f (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = -0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques.
Collapse
|
4
|
Aramendía-Vidaurreta V, Solis-Barquero SM, Ezponda A, Vidorreta M, Echeverria-Chasco R, Pascual M, Bastarrika G, Fernández-Seara MA. Assessment of Splenic Switch-Off With Arterial Spin Labeling in Adenosine Perfusion Cardiac MRI. J Magn Reson Imaging 2022. [PMID: 36218288 DOI: 10.1002/jmri.28460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/21/2022] [Accepted: 09/22/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND In patients with suspected coronary artery disease (CAD), myocardial perfusion is assessed under rest and pharmacological stress to identify ischemia. Splenic switch-off, defined as the stress to rest splenic perfusion attenuation in response to adenosine, has been proposed as an indicator of stress adequacy. Its occurrence has been previously assessed in first-pass perfusion images, but the use of noncontrast techniques would be highly beneficial. PURPOSE To explore the ability of pseudo-continuous arterial spin labeling (PCASL) to identify splenic switch-off in patients with suspected CAD. STUDY TYPE Prospective. POPULATION Five healthy volunteers (age 24.8 ± 3.8 years) and 32 patients (age 66.4 ± 8.2 years) with suspected CAD. FIELD STRENGTH/SEQUENCE A 1.5-T/PCASL (spin-echo) and first-pass imaging (gradient-echo). ASSESSMENT In healthy subjects, multi-delay PCASL data (500-2000 msec) were acquired to quantify splenic blood flow (SBF) and determine the adequate postlabeling delay (PLD) for single-delay acquisitions (PLD > arterial transit time). In patients, single-delay PCASL (1200 msec) and first-pass perfusion images were acquired under rest and adenosine conditions. PCASL data were used to compute SBF maps and SBF stress-to-rest ratios. Three observers classified patients into "switch-off" and "failed switch-off" groups by visually comparing rest-stress perfusion data acquired with PCASL and first-pass, independently. First-pass categories were used as reference to evaluate the accuracy of quantitative classification. STATISTICAL TESTS Wilcoxon signed-rank, Pearson correlation, kappa, percentage agreement, Generalized Linear Mixed Model, Mann-Whitney, Pearson Chi-squared, receiver operating characteristic, area-under-the-curve (AUC) and confusion matrix. SIGNIFICANCE P value < 0.05. RESULTS A total of 27 patients (84.4%) experienced splenic switch-off according to first-pass categories. Comparison of PCASL-derived SBF maps during stress and rest allowed assessment of splenic switch-off, reflected in a reduction of SBF values during stress. SBF stress-to-rest ratios showed a 97% accuracy (sensitivity = 80%, specificity = 100%, AUC = 85.2%). DATA CONCLUSION This study could demonstrate the feasibility of PCASL to identify splenic switch-off during adenosine perfusion MRI, both by qualitative and quantitative assessments. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: 2.
Collapse
|
5
|
Gutiérrez-Montes C, Coenen W, Vidorreta M, Sincomb S, Martínez-Bazán C, Sánchez AL, Haughton V. Effect of Normal Breathing on the Movement of CSF in the Spinal Subarachnoid Space. AJNR Am J Neuroradiol 2022; 43:1369-1374. [PMID: 35981761 PMCID: PMC9451622 DOI: 10.3174/ajnr.a7603] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/24/2022] [Indexed: 01/26/2023]
Abstract
BACKGROUND AND PURPOSE Forced respirations reportedly have an effect on CSF movement in the spinal canal. We studied respiratory-related CSF motion during normal respiration. MATERIALS AND METHODS Six healthy subjects breathed at their normal rate with a visual guide to ensure an unchanging rhythm. Respiratory-gated phase-contrast MR flow images were acquired at 5 selected axial planes along the spine. At each spinal level, we computed the flow rate voxelwise in the spinal canal, together with the associated stroke volume. From these data, we computed the periodic volume changes of spinal segments. A phantom was used to quantify the effect of respiration-related magnetic susceptibility changes on the velocity data measured. RESULTS At each level, CSF moved cephalad during inhalation and caudad during expiration. While the general pattern of fluid movement was the same in the 6 subjects, the flow rates, stroke volumes, and spine segment volume changes varied among subjects. Peak flow rates ranged from 0.60 to 1.59 mL/s in the cervical region, 0.46 to 3.17 mL/s in the thoracic region, and 0.75 to 3.64 mL/s in the lumbar region. The differences in flow rates along the canal yielded cyclic volume variations of spine segments that were largest in the lumbar spine, ranging from 0.76 to 3.07 mL among subjects. In the phantom study, flow velocities oscillated periodically during the respiratory cycle by up to 0.02 cm/s or 0.5%. CONCLUSIONS Respiratory-gated measurements of the CSF motion in the spinal canal showed cyclic oscillatory movements of spinal fluid correlated to the breathing pattern.
Collapse
|
6
|
Meiriño R, Calvo Manuel F, Burguete J, Serrano Andreu J, Aristu J, Azcona D, Cambeiro M, Vidorreta M, Pascau J, Delgado J, Alonso A. PO-1885 Analysis of Vascular and Circular Blood in Radiation Treatment Planning: Technological Options. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)03848-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
Hwuang E, Wu PH, Rodriguez-Soto A, Langham M, Wehrli FW, Vidorreta M, Moon B, Kochar K, Parameshwaran S, Koelper N, Tisdall MD, Detre JA, Witschey W, Schwartz N. Cross-modality and in-vivo validation of 4D flow MRI evaluation of uterine artery blood flow in human pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:722-731. [PMID: 32898295 PMCID: PMC8072518 DOI: 10.1002/uog.23112] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 08/06/2020] [Accepted: 08/23/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Clinical assessment of uterine artery (UtA) hemodynamics is currently limited to Doppler ultrasound (US) velocimetry. We have demonstrated previously the feasibility of applying four-dimensional (4D) flow magnetic resonance imaging (MRI) to evaluate UtA hemodynamics during pregnancy, allowing flow quantification of the entire course of the vessel. In this study, we sought to further validate the physiological relevance of 4D flow MRI measurement of UtA blood flow by exploring its association with pregnancy outcome relative to US-based metrics. METHODS Recruited into this prospective, cross-sectional study were 87 women with a singleton pregnancy who underwent 4D flow MRI between May 2016 and April 2019 to measure the UtA pulsatility index (MRI-PI) and blood flow rate (MRI-flow, in mL/min). UtA-PI was also measured using US (US-PI). The primary outcome was a composite (COMP) of pre-eclampsia (PE) and/or small-for-gestational-age (SGA) neonate, and secondary outcomes were PE and SGA neonate individually. We assessed the ability of MRI-flow, MRI-PI and US-PI to distinguish between outcomes, and evaluated whether MRI-flow changed as gestation progressed. RESULTS Following 4D flow postprocessing and exclusions from the analysis, 74 women had 4D flow MRI data analyzed for both UtAs. Of these, 18 developed a COMP outcome: three developed PE only, 11 had a SGA neonate only and four had both. A comparison of the COMP group vs the no-COMP group found no differences in maternal age, body mass index, nulliparity, gravidity or race. For 66 of the 74 subjects, US data were also available. In these subjects, both median MRI-PI (0.95 vs 0.70; P < 0.01) and median US-PI (0.95 vs 0.73; P < 0.01) were significantly increased in subjects in the COMP group compared with those in the no-COMP group. The UtA blood-flow rate, as measured by MRI, did not increase significantly from the second to the third trimester (median flow (interquartile range (IQR)), 543 (419-698) vs 575 (440-746) mL/min; P = 0.77), but it was significantly lower overall in the COMP compared with the no-COMP group (median flow (IQR), 486 (366-598) vs 624 (457-749) mL/min; P = 0.04). The areas under the receiver-operating-characteristics curves for MRI-flow, MRI-PI and US-PI in predicting COMP were not significantly different (0.694, 0.737 and 0.731, respectively; P = 0.87). CONCLUSIONS 4D flow MRI can yield physiological measures of UtA blood-flow rate and PI that are associated with adverse pregnancy outcome. This may open up new avenues in the future to expand the potential of this technique as a robust tool with which to evaluate UtA hemodynamics in pregnancy. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
8
|
Aramendía-Vidaurreta V, Gordaliza PM, Vidorreta M, Echeverría-Chasco R, Bastarrika G, Muñoz-Barrutia A, Fernández-Seara MA. Reduction of motion effects in myocardial arterial spin labeling. Magn Reson Med 2021; 87:1261-1275. [PMID: 34644410 DOI: 10.1002/mrm.29038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 09/09/2021] [Accepted: 09/20/2021] [Indexed: 11/09/2022]
Abstract
PURPOSE To evaluate the accuracy and reproducibility of myocardial blood flow measurements obtained under different breathing strategies and motion correction techniques with arterial spin labeling. METHODS A prospective cardiac arterial spin labeling study was performed in 12 volunteers at 3 Tesla. Perfusion images were acquired twice under breath-hold, synchronized-breathing, and free-breathing. Motion detection based on the temporal intensity variation of a myocardial voxel, as well as image registration based on pairwise and groupwise approaches, were applied and evaluated in synthetic and in vivo data. A region of interest was drawn over the mean perfusion-weighted image for quantification. Original breath-hold datasets, analyzed with individual regions of interest for each perfusion-weighted image, were considered as reference values. RESULTS Perfusion measurements in the reference breath-hold datasets were in line with those reported in literature. In original datasets, prior to motion correction, myocardial blood flow quantification was significantly overestimated due to contamination of the myocardial perfusion with the high intensity signal of blood pool. These effects were minimized with motion detection or registration. Synthetic data showed that accuracy of the perfusion measurements was higher with the use of registration, in particular after the pairwise approach, which probed to be more robust to motion. CONCLUSION Satisfactory results were obtained for the free-breathing strategy after pairwise registration, with higher accuracy and robustness (in synthetic datasets) and higher intrasession reproducibility together with lower myocardial blood flow variability across subjects (in in vivo datasets). Breath-hold and synchronized-breathing after motion correction provided similar results, but these breathing strategies can be difficult to perform by patients.
Collapse
|
9
|
Solis-Barquero SM, Echeverria-Chasco R, Calvo-Imirizaldu M, Cacho-Asenjo E, Martinez-Simon A, Vidorreta M, Dominguez PD, García de Eulate R, Fernandez-Martinez M, Fernández-Seara MA. Breath-Hold Induced Cerebrovascular Reactivity Measurements Using Optimized Pseudocontinuous Arterial Spin Labeling. Front Physiol 2021; 12:621720. [PMID: 33679436 PMCID: PMC7925895 DOI: 10.3389/fphys.2021.621720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 01/26/2021] [Indexed: 11/13/2022] Open
Abstract
A pseudocontinuous arterial spin labeling (PCASL) sequence combined with background suppression and single-shot accelerated 3D RARE stack-of-spirals was used to evaluate cerebrovascular reactivity (CVR) induced by breath-holding (BH) in ten healthy volunteers. Four different models designed using the measured change in PETCO2 induced by BH were compared, for CVR quantification. The objective of this comparison was to understand which regressor offered a better physiological model to characterize the cerebral blood flow response under BH. The BH task started with free breathing of 42 s, followed by interleaved end-expiration BHs of 21 s, for ten cycles. The total scan time was 12 min and 20 s. The accelerated readout allowed the acquisition of PCASL data with better temporal resolution than previously used, without compromising the post-labeling delay. Elevated CBF was observed in most cerebral regions under hypercapnia, which was delayed with respect to the BH challenge. Significant statistical differences in CVR were obtained between the different models in GM (p < 0.0001), with ramp models yielding higher values than boxcar models and between the two tissues, GM and WM, with higher values in GM, in all the models (p < 0.0001). The adjustment of the ramp amplitude during each BH cycle did not improve the results compared with a ramp model with a constant amplitude equal to the mean PETCO2 change during the experiment.
Collapse
|
10
|
Aramendía-Vidaurreta V, Echeverría-Chasco R, Vidorreta M, Bastarrika G, Fernández-Seara MA. Quantification of Myocardial Perfusion With Vasodilation Using Arterial Spin Labeling at 1.5T. J Magn Reson Imaging 2020; 53:777-788. [PMID: 33063433 DOI: 10.1002/jmri.27396] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 09/26/2020] [Accepted: 09/29/2020] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND Myocardial perfusion is evaluated in first-pass MRI using a gadolinium-based contrast agent, which limits its repeatability and restricts its use in patients with abnormal kidney function. Arterial spin labeling (ASL) is a promising technique for measuring myocardial perfusion without contrast injection. The ratio of stress to rest perfusion, termed myocardial perfusion reserve (MPR), is an indicator of the severity of stenosis in patients with coronary artery disease (CAD). PURPOSE To quantify perfusion increases with pharmacological vasodilation, explore MPR differences between segments with and without perfusion defects, and examine the correlations between quantitative ASL and semiquantitative first-pass measurements. STUDY TYPE Prospective. SUBJECTS Sixteen patients with suspected CAD: 10 classified as "healthy," having normal perfusion on first-pass and no enhancement on late gadolinium enhancement (LGE), and six as "nonhealthy," having hypoperfused segments including ischemic and infarcted. FIELD STRENGTH/SEQUENCE Flow-sensitive alternating inversion recovery (FAIR) rest-stress cardiac ASL with balanced steady-state free precession (bSSFP), rest-stress first-pass imaging using gradient-echo and LGE using a phase-sensitive inversion-recovery bSSFP at 1.5T. ASSESSMENT For healthy subjects, rest-stress perfusion data were compared in global, coronary artery territory, and segment regions of interest (ROIs). A segmental MPR comparison was performed between normal segments from healthy subjects and abnormal segments from nonhealthy subjects. Correlations between ASL and first-pass parameters were explored. STATISTICAL TESTS Wilcoxon-signed-rank test, nonparametric factorial analysis of variance (ANOVA), and Pearson's/Spearman's correlations. RESULTS Perfusion increases were significant globally (P = 0.005), per coronary artery territory (P = 0.015), and per segment (P = 0.03 for all segments in ASL and first-pass, except anteroseptal in ASL P = 0.04). MPR differences between normal and abnormal segments were significant (P = 0.0028: ASL, P = 0.033: first-pass). ASL and first-pass measurements were correlated (MPR: r = 0.64, P = 0.008 and perfusion: rho = 0.47, P = 0.007). DATA CONCLUSION This study demonstrates the feasibility of ASL to detect hyperemia, the potential to differentiate segments with and without perfusion defects, and significant correlations between ASL and semiquantitative first-pass. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
|
11
|
Echeverria-Chasco R, Vidorreta M, Aramendía-Vidaurreta V, Cano D, Escalada J, Garcia-Fernandez N, Bastarrika G, Fernández-Seara MA. Optimization of pseudo-continuous arterial spin labeling for renal perfusion imaging. Magn Reson Med 2020; 85:1507-1521. [PMID: 33017483 DOI: 10.1002/mrm.28531] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 09/03/2020] [Accepted: 09/03/2020] [Indexed: 11/09/2022]
Abstract
PURPOSE To evaluate labeling efficiency of pseudo-continuous arterial spin labeling (PCASL) and to find the gradient parameters that increase PCASL robustness for renal perfusion measurements. METHODS Aortic blood flow was characterized in 3 groups: young healthy volunteers (YHV1), chronic kidney disease (CKD) patients (CKDP), and healthy controls (HCO). PCASL inversion efficiency was evaluated through numeric simulations considering the measured pulsatile flow velocity profiles and off-resonance effects for a wide range of gradient parameters, and the results were assessed in vivo. The most robust PCASL implementation was used to measure renal blood flow (RBF) in CKDP and HCO. RESULTS Aortic blood velocities reached peak values of 120 cm/s in YHV1, whereas for elderly subjects values were lower by approximately a factor of 2. Simulations and experiments showed that by reducing the gradient average (Gave ) and the selective to average gradient ratio (Gmax /Gave ), labeling efficiency was maximized and PCASL robustness to off-resonance was improved. The study in CKDP and HCO showed significant differences in RBF between groups. CONCLUSION An efficient and robust PCASL scheme for renal applications requires a Gmax /Gave ratio of 6-7 and a Gave value that depends on the aortic blood flow velocities (0.5 mT/m being appropriate for CKDP and HCO).
Collapse
|
12
|
Englund EK, Fernández-Seara MA, Rodríguez-Soto AE, Lee H, Rodgers ZB, Vidorreta M, Detre JA, Wehrli FW. Calibrated fMRI for dynamic mapping of CMRO 2 responses using MR-based measurements of whole-brain venous oxygen saturation. J Cereb Blood Flow Metab 2020; 40:1501-1516. [PMID: 31394960 PMCID: PMC7308517 DOI: 10.1177/0271678x19867276] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Functional MRI (fMRI) can identify active foci in response to stimuli through BOLD signal fluctuations, which represent a complex interplay between blood flow and cerebral metabolic rate of oxygen (CMRO2) changes. Calibrated fMRI can disentangle the underlying contributions, allowing quantification of the CMRO2 response. Here, whole-brain venous oxygen saturation (Yv) was computed alongside ASL-measured CBF and BOLD-weighted data to derive the calibration constant, M, using the proposed Yv-based calibration. Data were collected from 10 subjects at 3T with a three-part interleaved sequence comprising background-suppressed 3D-pCASL, 2D BOLD-weighted, and single-slice dual-echo GRE (to measure Yv via susceptometry-based oximetry) acquisitions while subjects breathed normocapnic/normoxic, hyperoxic, and hypercapnic gases, and during a motor task. M was computed via Yv-based calibration from both hypercapnia and hyperoxia stimulus data, and results were compared to conventional hypercapnia or hyperoxia calibration methods. Mean M in gray matter did not significantly differ between calibration methods, ranging from 8.5 ± 2.8% (conventional hyperoxia calibration) to 11.7 ± 4.5% (Yv-based calibration in response to hyperoxia), with hypercapnia-based M values between (p = 0.56). Relative CMRO2 changes from finger tapping were computed from each M map. CMRO2 increased by ∼20% in the motor cortex, and good agreement was observed between the conventional and proposed calibration methods.
Collapse
|
13
|
Dolui S, Tisdall D, Vidorreta M, Jacobs DR, Nasrallah IM, Bryan RN, Wolk DA, Detre JA. Characterizing a perfusion-based periventricular small vessel region of interest. NEUROIMAGE-CLINICAL 2019; 23:101897. [PMID: 31233954 PMCID: PMC6595083 DOI: 10.1016/j.nicl.2019.101897] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Revised: 06/04/2019] [Accepted: 06/11/2019] [Indexed: 10/27/2022]
Abstract
The periventricular white matter (PVWM) is supplied by terminal distributions of small vessels and is particularly susceptible to developing white matter lesions (WML) associated with cerebral small vessel disease (CSVD). We obtained group-averaged cerebral blood flow (CBF) maps from Arterial Spin Labeled (ASL) perfusion MRI data obtained in 436 middle-aged (50.4 ± 3.5 years) subjects in the NHLBI CARDIA study and in 61 elderly (73.3 ± 6.9 years) cognitively normal subjects recruited from the Penn Alzheimer's Disease Center (ADC) and found that the lowest perfused brain voxels are located within the PVWM. We constructed a white matter periventricular small vessel (PSV) region of interest (ROI) by empirically thresholding the group averaged CARDIA CBF map at CBF < 15 ml/100 g/min. Thereafter we compared CBF in the PSV ROI and in the remaining white matter (RWM) with the location and volume of WML measured with Fluid Attenuated Inversion Recovery (FLAIR) MRI. WM CBF was lower within WML than outside WML voxels (p < <0.0001) in both the PSV and RWM ROIs, however this difference was much smaller (p < <0.0001) in the PSV ROI than in the RWM suggesting a more homogenous reduction of CBF in the PSV region. Normalized WML volumes were significantly higher in the PSV ROI than in the RWM and in the elderly cohort as compared to the middle-aged cohort (p < <0.0001). Additionally, the PSV ROI showed a significantly (p = .001) greater increase in lesion volume than the RWM in the elderly ADC cohort than the younger CARDIA cohort. Considerable intersubject variability in PSV CBF observed in both study cohorts likely represents biological variability that may be predictive of future WML and/or cognitive decline. In conclusion, a data-driven PSV ROI defined by voxels with low perfusion in middle age defines a region with homogeneously reduced CBF that is particularly susceptible to progressive ischemic injury in elderly controls. PSV CBF may provide a mechanistically specific biomarker of CSVD.
Collapse
|
14
|
Aramendía-Vidaurreta V, García-Osés A, Vidorreta M, Bastarrika G, Fernández-Seara MA. Optimal repetition time for free breathing myocardial arterial spin labeling. NMR IN BIOMEDICINE 2019; 32:e4077. [PMID: 30811728 DOI: 10.1002/nbm.4077] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 12/21/2018] [Accepted: 01/15/2019] [Indexed: 06/09/2023]
Abstract
The aim of this study was to improve the scan efficiency of ASL in the myocardium. Free breathing FAIR-ASL scans with different TRs were compared, while keeping the acquisition time constant. Scans were named by the trigger pulse that started each acquisition: every two (TP1), four (TP2) and six (TP3) cardiac cycles. TP2 offered the best alternative with a coefficient of variation of 17.15% intrasession and 36.85% intersession. Mean MBF increased by 0.22 ± 0.41 ml/g/min with mild stress.
Collapse
|
15
|
Schwartz N, Hwuang E, Rodriguez-Soto A, Wehrli F, Vidorreta M, Moon BF, Kochar K, Parameshwaran S, Koelper NC, Sammel MD, Tisdall MD, Detre J, Witschey WR. 1050: Cross-modality, in-vivo validation of 4D-Flow MRI evaluation of uterine artery blood flow in human pregnancy. Am J Obstet Gynecol 2019. [DOI: 10.1016/j.ajog.2018.11.1074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Hwuang E, Vidorreta M, Schwartz N, Moon BF, Kochar K, Tisdall MD, Detre JA, Witschey WRT. Assessment of uterine artery geometry and hemodynamics in human pregnancy with 4d flow mri and its correlation with doppler ultrasound. J Magn Reson Imaging 2018; 49:59-68. [PMID: 30390347 DOI: 10.1002/jmri.26229] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 05/31/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Uterine artery (UtA) hemodynamics might be used to predict risk of hypertensive pregnancy disorders, including preeclampsia and intrauterine growth restriction. PURPOSE OR HYPOTHESIS To determine the feasibility of 4D flow MRI in pregnant subjects by characterizing UtA anatomy, computing UtA flow, and comparing UtA velocity, and pulsatility and resistivity indices (PI, RI) with transabdominal Doppler ultrasound (US). STUDY TYPE Prospective cross-sectional study from June 6, 2016, to May 2, 2018. POPULATION OR SUBJECTS OR PHANTOM OR SPECIMEN OR ANIMAL MODEL Forty-one singleton pregnant subjects (age [range] = 27.0 ± 5.9 [18-41] years) in their second or third trimester. We additionally scanned three subjects who had prepregnancy diabetes or chronic hypertension. FIELD STRENGTH/SEQUENCE The subjects underwent UtA and placenta MRI using noncontrast angiography and 4D flow at 1.5T. ASSESSMENT UtA anatomy was described based on 4D flow-derived noncontrast angiography, while UtA flow properties were characterized by net flow, systolic/mean/diastolic velocity, PI and RI through examination of 4D flow data. PI and RI are standard hemodynamic parameters routinely reported on Doppler US. STATISTICAL TESTS Spearman's rank correlation, Wilcoxon signed rank tests, and Bland-Altman plots were used to preliminarily investigate the relationships between flow parameters, gestational age, and Doppler US. or RESULTS: 4D flow MRI and UtA flow quantification was feasible in all subjects. There was considerable heterogeneity in UtA geometry in each subject between left and right UtAs and between subjects. Mean 4D flow-based parameters were: mean bilateral flow rate = 605.6 ± 220.5 mL/min, PI = 0.72 ± 0.2, and RI = 0.47 ± 0.1. Bilateral flow did not change with gestational age. We found that MRI differed from US in terms of lower PI (mean difference -0.1) and RI (mean difference < -0.1) with Wilcoxon signed rank test P = 0.05 and P = 0.13, respectively. DATA CONCLUSION 4D flow MRI is a feasible approach for describing UtA anatomy and flow in pregnant subjects. LEVEL OF EVIDENCE Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:59-68.
Collapse
|
17
|
de Eulate RG, Goñi I, Galiano A, Vidorreta M, Recio M, Riverol M, Zubieta JL, Fernández-Seara MA. Reduced Cerebral Blood Flow in Mild Cognitive Impairment Assessed Using Phase-Contrast MRI. J Alzheimers Dis 2018; 58:585-595. [PMID: 28453476 DOI: 10.3233/jad-161222] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
There is increasing evidence of a vascular contribution to Alzheimer's disease (AD). In some cases, prior work suggests that chronic brain hypoperfusion could play a prime pathogenic role contributing to the accumulation of amyloid-β,while other studies favor the hypothesis that vascular dysfunction and amyloid pathology are independent, although synergistic, mechanisms contributing to cognitive impairment. Vascular dysfunction can be evaluated by assessing cerebral blood flow impairment. Phase contrast velocity mapping by MRI offers a non-invasive means of quantifying the total inflow of blood to the brain. This quantitative parameter could be a sensitive indicator of vascular disease at early stages of AD. In this work, phase contrast MRI was used to evaluate cerebral hemodynamics in patients with subjective memory complaints, amnestic mild cognitive impairment, and mild to moderate AD, and compare them with control subjects. Results showed that blood flow and velocity were decreased in the patients with cognitive dysfunction and the decrease correlated with the degree of cognitive impairment as assessed by means of neuropsychological tests. Total cerebral blood flow measurements were clearly reduced in AD patients, but more importantly appeared to be sensitive enough to distinguish between healthy subjects and those with mild cognitive impairment. A quantitative measurement of total brain blood flow could potentially predict vascular dysfunction and compromised brain perfusion in early stages of AD.
Collapse
|
18
|
Li Z, Vidorreta M, Katchmar N, Alsop DC, Wolf DH, Detre JA. Effects of resting state condition on reliability, trait specificity, and network connectivity of brain function measured with arterial spin labeled perfusion MRI. Neuroimage 2018; 173:165-175. [PMID: 29454933 PMCID: PMC5957091 DOI: 10.1016/j.neuroimage.2018.02.028] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Revised: 02/06/2018] [Accepted: 02/14/2018] [Indexed: 12/22/2022] Open
Abstract
Resting state fMRI (rs-fMRI) provides imaging biomarkers of task-independent brain function that can be associated with clinical variables or modulated by interventions such as behavioral training or pharmacological manipulations. These biomarkers include time-averaged regional brain function as manifested by regional cerebral blood flow (CBF) measured using arterial spin labeled (ASL) perfusion MRI and correlated temporal fluctuations of function across brain networks with either ASL or blood oxygenation level dependent (BOLD) fMRI. Resting-state studies are typically carried out using just one of several prescribed state conditions such as eyes closed (EC), eyes open (EO), or visual fixation on a cross-hair (FIX), which may affect the reliability and specificity of rs-fMRI. In this study, we collected test-retest ASL MRI data during 4 resting-state task conditions: EC, EO, FIX and PVT (low-frequency psychomotor vigilance task), and examined the effects of these task conditions on reliability and reproducibility as well as trait specificity of regional brain function. We also acquired resting-state BOLD fMRI under FIX and compared the network connectivity reliabilities between the four ASL conditions and the BOLD FIX condition. For resting-state ASL data, EC provided the highest CBF reliability, reproducibility, trait specificity, and network connectivity reliability, followed by EO, while FIX was lowest on all of these measures. PVT demonstrated lower CBF reliability, reproducibility and trait specificity than EO and EC. Overall network connectivity reliability was comparable between ASL and BOLD. Our findings confirm ASL CBF as a reliable, stable, and consistent measure of resting-state regional brain function and support the use of EC or EO over FIX and PVT as the resting-state condition.
Collapse
|
19
|
Zhao L, Vidorreta M, Soman S, Detre JA, Alsop DC. Improving the robustness of pseudo-continuous arterial spin labeling to off-resonance and pulsatile flow velocity. Magn Reson Med 2017; 78:1342-1351. [PMID: 27774656 PMCID: PMC5848499 DOI: 10.1002/mrm.26513] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 09/01/2016] [Accepted: 09/26/2016] [Indexed: 01/22/2023]
Abstract
PURPOSE To improve pseudo-continuous arterial spin labeling (PCASL) robustness to off-resonance and pulsatile blood flow velocity. METHODS Bloch equations were solved to evaluate the effect of labeling parameters in a pulsatile flow model for a range of off-resonance. Experimental confirmation was achieved in volunteers using linear phase increase between labeling pulses to approximate off-resonance errors. We first assessed the location of the labeling plane in four volunteers. Next, we explored a range of parameters-including balanced and unbalanced gradients-in five more volunteers at an optimal labeling plane location. RESULTS Simulations demonstrated that 1) high velocities are vulnerable to off-resonance, 2) unbalanced PCASL outperforms balanced PCASL, 3) increased B1 and low average gradient improve the labeling efficiency for high-velocity flow, and 4) a low ratio of selective to average gradient improves off-resonance robustness. A good agreement between theory and experiment was observed. CONCLUSION The robustness of PCASL can be increased by selecting an unbalanced scheme with a low average gradient (0.5 mT/m), a low ratio (7×) of selective to average gradients, and the highest feasible B1 (1.8 μT). Placing the labeling plane above the carotid bifurcation and below the V3 segment, usually between the second and third vertebrae, yielded robust results. Magn Reson Med 78:1342-1351, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
20
|
Dolui S, Vidorreta M, Wang Z, Nasrallah IM, Alavi A, Wolk DA, Detre JA. Comparison of PASL, PCASL, and background-suppressed 3D PCASL in mild cognitive impairment. Hum Brain Mapp 2017; 38:5260-5273. [PMID: 28737289 DOI: 10.1002/hbm.23732] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 05/30/2017] [Accepted: 07/09/2017] [Indexed: 12/21/2022] Open
Abstract
We compared three implementations of single-shot arterial spin labeled (ASL) perfusion magnetic resonance imaging: two-dimensional (2D) pulsed ASL (PASL), 2D pseudocontinuous ASL (PCASL), and background-suppressed (BS) 3D PCASL obtained in a cohort of patients with mild cognitive impairment (MCI) and elderly controls. Study subjects also underwent 18 F-fluorodeoxyglucose positron emission tomography (18 F-FDG PET). While BS 3D PCASL showed the lowest (P < 0.001) gray matter-white matter cerebral blood flow (CBF) contrast ratio, it provided the highest (P < 0.001) temporal signal-to-noise ratio. Mean relative CBF estimated using the PCASL methods in posterior cingulate cortex (PCC), precuneus, and hippocampus showed hypoperfusion in the MCI cohort compared to the controls consistent with hypometabolism measured by 18 F-FDG PET. BS 3D PCASL demonstrated the highest discrimination between controls and patients with effect size comparable to that seen with 18 F-FDG PET. 2D PASL did not demonstrate group differentiation with relative CBF in any ROI, whereas 2D PCASL demonstrated significant differences only in PCC and hippocampus. Mean global CBF values did not differ across methods and were highly correlated; however, the correlations were significantly higher (P < 0.001) when either the same labeling (PCASL) or the same acquisition strategy (2D) was used as compared to when both the labeling and readout methods differed. In addition, there were differences in regional distribution of CBF between the three modalities, which can be attributed to differences in sequence parameters. These results demonstrate the superiority of ASL with PCASL and BS 3D readout as a biomarker for regional brain function changes in MCI. Hum Brain Mapp 38:5260-5273, 2017. © 2017 Wiley Periodicals, Inc.
Collapse
|
21
|
Chang YV, Vidorreta M, Wang Z, Detre JA. 3D-accelerated, stack-of-spirals acquisitions and reconstruction of arterial spin labeling MRI. Magn Reson Med 2016; 78:1405-1419. [PMID: 27813164 DOI: 10.1002/mrm.26549] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 10/15/2016] [Accepted: 10/17/2016] [Indexed: 11/07/2022]
Abstract
PURPOSE The goal of this study was to develop a 3D acceleration and reconstruction method to improve image quality and resolution of background-suppressed arterial spin-labeled perfusion MRI. METHODS Accelerated acquisition was implemented in all three k-space dimensions in a stack-of-spirals readout using variable density spirals and partition undersampling. A single 3D self-consistent parallel imaging (SPIRiT) kernel was calibrated and iteratively applied to reconstruct each imaging volume. Whole-brain (including cerebellum) perfusion imaging was obtained at 3-mm isotropic resolution (nominal) using single- and 2-shot acquisitions and at 2-mm isotropic resolution (nominal) using four-shot acquisitions, achieving effective acceleration factors between 5.5 and 6.6. The signal-to-noise (SNR) performance of 3D SPIRiT was evaluated. The temporal SNR (tSNR) of the cerebral blood flow (CBF) maps and the gray/white matter CBF ratios were quantified. RESULTS The readout of the arterial spin labeling (ASL) sequence was significantly shortened with acceleration. The CBF values were consistent between accelerated and fully sampled ASL. With shorter spiral interleaves and shorter echo trains, the accelerated images demonstrated reduced blurring and signal dropout in regions with high susceptibility gradients, resulting in improved image quality and increased gray/white matter CBF ratios. The shortened readout was accompanied by a corresponding decrease in tSNR. CONCLUSION The 3D acceleration and reconstruction allow a rapid whole-brain readout that improved the quality of ASL perfusion imaging. Magn Reson Med 78:1405-1419, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
22
|
Martínez M, Valencia M, Vidorreta M, Luis EO, Castellanos G, Villagra F, Fernández-Seara MA, Pastor MA. Trade-off between frequency and precision during stepping movements: Kinematic and BOLD brain activation patterns. Hum Brain Mapp 2016; 37:1722-37. [PMID: 26857613 DOI: 10.1002/hbm.23131] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 11/17/2015] [Accepted: 01/21/2016] [Indexed: 11/11/2022] Open
Abstract
The central nervous system has the ability to adapt our locomotor pattern to produce a wide range of gait modalities and velocities. In reacting to external pacing stimuli, deviations from an individual preferred cadence provoke a concurrent decrease in accuracy that suggests the existence of a trade-off between frequency and precision; a compromise that could result from the specialization within the control centers of locomotion to ensure a stable transition and optimal adaptation to changing environment. Here, we explore the neural correlates of such adaptive mechanisms by visually guiding a group of healthy subjects to follow three comfortable stepping frequencies while simultaneously recording their BOLD responses and lower limb kinematics with the use of a custom-built treadmill device. In following the visual stimuli, subjects adopt a common pattern of symmetric and anti-phase movements across pace conditions. However, when increasing the stimulus frequency, an improvement in motor performance (precision and stability) was found, which suggests a change in the control mode from reactive to predictive schemes. Brain activity patterns showed similar BOLD responses across pace conditions though significant differences were observed in parietal and cerebellar regions. Neural correlates of stepping precision were found in the insula, cerebellum, dorsolateral pons and inferior olivary nucleus, whereas neural correlates of stepping stability were found in a distributed network, suggesting a transition in the control strategy across the stimulated range of frequencies: from unstable/reactive at lower paces (i.e., stepping stability managed by subcortical regions) to stable/predictive at higher paces (i.e., stability managed by cortical regions). Hum Brain Mapp 37:1722-1737, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
|
23
|
Castellanos G, Fernández-Seara MA, Lorenzo-Betancor O, Ortega-Cubero S, Puigvert M, Uranga J, Vidorreta M, Irigoyen J, Lorenzo E, Muñoz-Barrutia A, Ortiz-de-Solorzano C, Pastor P, Pastor MA. Automated neuromelanin imaging as a diagnostic biomarker for Parkinson's disease. Mov Disord 2015; 30:945-52. [PMID: 25772492 DOI: 10.1002/mds.26201] [Citation(s) in RCA: 117] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Revised: 01/20/2015] [Accepted: 02/09/2015] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND We aimed to analyze the diagnostic accuracy of an automated segmentation and quantification method of the SNc and locus coeruleus (LC) volumes based on neuromelanin (NM)-sensitive MRI (NM-MRI) in patients with idiopathic (iPD) and monogenic (iPD) Parkinson's disease (PD). METHODS Thirty-six patients (23 idiopathic and 13 monogenic PARKIN or LRRK2 mutations) and 37 age-matched healthy controls underwent 3T-NM-MRI. SNc and LC volumetry were performed using fully automated multi-image atlas segmentation. The diagnostic performance to differentiate PD from controls was measured using the area under the curve (AUC) and likelihood ratios based on receiver operating characteristic (ROC) analyses. RESULTS We found a significant reduction of SNc and LC volumes in patients, when compared to controls. ROC analysis showed better diagnostic accuracy when using SNc volume than LC volume. Significant differences between ipsilateral and contralateral SNc volumes, in relation to the more clinically affected side, were found in patients with iPD (P = 0.007). Contralateral atrophy in the SNc showed the highest power to discriminate PD subjects from controls (AUC, 0.93-0.94; sensitivity, 91%-92%; specificity, 89%; positive likelihood ratio: 8.4-8.5; negative likelihood ratio: 0.09-0.1 at a single cut-off point). Interval likelihood ratios for contralateral SNc volume improved the diagnostic accuracy of volumetric measurements. CONCLUSION SNc and LC volumetry based on NM-MRI resulting from the automated segmentation and quantification technique can yield high diagnostic accuracy for differentiating PD from health and might be an unbiased disease biomarker. © 2015 International Parkinson and Movement Disorder Society.
Collapse
|
24
|
Fernández-Seara MA, Mengual E, Vidorreta M, Castellanos G, Irigoyen J, Erro E, Pastor MA. Resting state functional connectivity of the subthalamic nucleus in Parkinson's disease assessed using arterial spin-labeled perfusion fMRI. Hum Brain Mapp 2015; 36:1937-50. [PMID: 25641065 DOI: 10.1002/hbm.22747] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 12/02/2014] [Accepted: 01/13/2015] [Indexed: 12/24/2022] Open
Abstract
Neurophysiological changes within the cortico-basal ganglia-thalamocortical circuits appear to be a characteristic of Parkinson's disease (PD) pathophysiology. The subthalamic nucleus (STN) is one of the basal ganglia components showing pathological neural activity patterns in PD. In this study, perfusion imaging data, acquired noninvasively using arterial spin-labeled (ASL) perfusion MRI, were used to assess the resting state functional connectivity (FC) of the STN in 24 early-to-moderate PD patients and 34 age-matched healthy controls, to determine whether altered FC in the very low frequency range of the perfusion time signal occurs as a result of the disease. Our results showed that the healthy STN was functionally connected with other nuclei of the basal ganglia and the thalamus, as well as with discrete cortical areas including the insular cortex and the hippocampus. In PD patients, connectivity of the STN was increased with two cortical areas involved in motor and cognitive processes. These findings suggest that hyperconnectivity of the STN could underlie some of the motor and cognitive deficits often present even at early stages of the disease. The FC measures provided good discrimination between controls and patients, suggesting that ASL-derived FC metrics could be a putative PD biomarker.
Collapse
|
25
|
Vidorreta M, Balteau E, Wang Z, De Vita E, Pastor MA, Thomas DL, Detre JA, Fernández-Seara MA. Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T. NMR IN BIOMEDICINE 2014; 27:1387-96. [PMID: 25263944 PMCID: PMC4233410 DOI: 10.1002/nbm.3201] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Revised: 07/18/2014] [Accepted: 08/17/2014] [Indexed: 05/23/2023]
Abstract
Recent technical developments have significantly increased the signal-to-noise ratio (SNR) of arterial spin labeled (ASL) perfusion MRI. Despite this, typical ASL acquisitions still employ large voxel sizes. The purpose of this work was to implement and evaluate two ASL sequences optimized for whole-brain high-resolution perfusion imaging, combining pseudo-continuous ASL (pCASL), background suppression (BS) and 3D segmented readouts, with different in-plane k-space trajectories. Identical labeling and BS pulses were implemented for both sequences. Two segmented 3D readout schemes with different in-plane trajectories were compared: Cartesian (3D GRASE) and spiral (3D RARE Stack-Of-Spirals). High-resolution perfusion images (2 × 2 × 4 mm(3) ) were acquired in 15 young healthy volunteers with the two ASL sequences at 3 T. The quality of the perfusion maps was evaluated in terms of SNR and gray-to-white matter contrast. Point-spread-function simulations were carried out to assess the impact of readout differences on the effective resolution. The combination of pCASL, in-plane segmented 3D readouts and BS provided high-SNR high-resolution ASL perfusion images of the whole brain. Although both sequences produced excellent image quality, the 3D RARE Stack-Of-Spirals readout yielded higher temporal and spatial SNR than 3D GRASE (spatial SNR = 8.5 ± 2.8 and 3.7 ± 1.4; temporal SNR = 27.4 ± 12.5 and 15.6 ± 7.6, respectively) and decreased through-plane blurring due to its inherent oversampling of the central k-space region, its reduced effective TE and shorter total readout time, at the expense of a slight increase in the effective in-plane voxel size.
Collapse
|
26
|
Martinez M, Villagra F, Loayza F, Vidorreta M, Arrondo G, Luis E, Diaz J, Echeverria M, Fernandez-Seara MA, Pastor MA. MRI-compatible device for examining brain activation related to stepping. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:1044-1053. [PMID: 24770910 DOI: 10.1109/tmi.2014.2301493] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Repetitive and alternating lower limb movements are a specific component of human gait. Due to technical challenges, the neural mechanisms underlying such movements have not been previously studied with functional magnetic resonance imaging. In this study, we present a novel treadmill device employed to investigate the kinematics and the brain activation patterns involved in alternating and repetitive movements of the lower limbs. Once inside the scanner, 19 healthy subjects were guided by two visual cues and instructed to perform a motor task which involved repetitive and alternating movements of both lower limbs while selecting their individual comfortable amplitude on the treadmill. The device facilitated the performance of coordinated stepping while registering the concurrent lower-limb displacements, which allowed us to quantify some movement primary kinematic features such as amplitude and frequency. During stepping, significant blood oxygen level dependent signal increases were observed bilaterally in primary and secondary sensorimotor cortex, the supplementary motor area, premotor cortex, prefrontal cortex, superior and inferior parietal lobules, putamen and cerebellum, regions that are known to be involved in lower limb motor control. Brain activations related to individual adjustments during motor performance were identified in a right lateralized network including striatal, extrastriatal, and fronto-parietal areas.
Collapse
|
27
|
Vidorreta M, Wang Z, Rodríguez I, Pastor MA, Detre JA, Fernández-Seara MA. Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences. Neuroimage 2012; 66:662-71. [PMID: 23142069 DOI: 10.1016/j.neuroimage.2012.10.087] [Citation(s) in RCA: 113] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Revised: 10/03/2012] [Accepted: 10/29/2012] [Indexed: 11/27/2022] Open
Abstract
Arterial spin labeling (ASL) can be implemented by combining different labeling schemes and readout sequences. In this study, the performance of 2D and 3D single-shot pulsed-continuous ASL (pCASL) sequences was assessed in a group of young healthy volunteers undergoing a baseline perfusion and a functional study with a sensory-motor activation paradigm. The evaluated sequences were 2D echo-planar imaging (2D EPI), 3D single-shot fast spin-echo with in-plane spiral readout (3D FSE spiral), and 3D single-shot gradient-and-spin-echo (3D GRASE). The 3D sequences were implemented with and without the addition of an optimized background suppression (BS) scheme. Labeling efficiency, signal-to-noise ratio (SNR), and gray matter (GM) to white matter (WM) contrast ratio were assessed in baseline perfusion measurements. 3D acquisitions without BS yielded 2-fold increments in spatial SNR, but no change in temporal SNR. The addition of BS to the 3D sequences yielded a 3-fold temporal SNR increase compared to the unsuppressed sequences. 2D EPI provided better GM-to-WM contrast ratio than the 3D sequences. The analysis of functional data at the subject level showed a 3-fold increase in statistical power for the BS 3D sequences, although the improvement was attenuated at the group level. 3D without BS did not increase the maximum t-values, however, it yielded larger activation clusters than 2D. These results demonstrate that BS 3D single-shot imaging sequences improve the performance of pCASL in baseline and activation studies, particularly for individual subject analyses where the improvement in temporal SNR translates into markedly enhanced power for task activation detection.
Collapse
|
28
|
van de Giessen M, van der Laan A, Hendriks EA, Vidorreta M, Reiber JHC, Jost CR, Tanke HJ, Lelieveldt BPF. Fully automated attenuation measurement and motion correction in FLIP image sequences. IEEE TRANSACTIONS ON MEDICAL IMAGING 2012; 31:461-473. [PMID: 21997250 DOI: 10.1109/tmi.2011.2171497] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. The measurements of the fluorescence attenuation are hampered by the low signal to noise ratio of the FLIP sequences, by sudden sample shifts and by sample drift. This paper describes a method that estimates the attenuation by modeling photobleaching as exponentially decaying signals. Sudden motion artifacts are minimized by registering the frames of a FLIP sequence to target frames based on the estimated model and by removing frames that contain deformations. Linear motion (sample drift) is reduced by minimizing the entropy of the estimated attenuation coefficients. Experiments on 16 in vivo FLIP sequences of muscle cells in Drosophila show that the proposed method results in fluorescence attenuations similar to the manually identified gold standard, but with standard deviations of approximately 50 times smaller. As a result of this higher precision, cell compartment edges and details such as cell nuclei become clearly discernible. The main value of this method is that it uses a model of the bleaching process to correct motion and that the model based fluorescence intensity and attenuation estimates can be interpreted easily. The proposed method is fully automatic, and runs in approximately one minute per sequence, making it suitable for unsupervised batch processing of large data series.
Collapse
|
29
|
Fernández-Seara MA, Mengual E, Vidorreta M, Aznárez-Sanado M, Loayza FR, Villagra F, Irigoyen J, Pastor MA. Cortical hypoperfusion in Parkinson's disease assessed using arterial spin labeled perfusion MRI. Neuroimage 2011; 59:2743-50. [PMID: 22032942 DOI: 10.1016/j.neuroimage.2011.10.033] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2011] [Revised: 10/06/2011] [Accepted: 10/10/2011] [Indexed: 12/18/2022] Open
Abstract
Alterations in cerebral perfusion and metabolism in Parkinson's disease have been assessed in several studies, using nuclear imaging techniques and more recently magnetic resonance imaging. However, to date there is no consensus in the literature regarding the extent and the magnitude of these alterations. In this work, arterial spin labeled perfusion MRI was employed to quantify absolute cerebral blood flow in a group of early-to-moderate Parkinson's disease patients and age-matched healthy controls. Perfusion comparisons between the two groups showed that Parkinson's disease is characterized by wide-spread cortical hypoperfusion. Subcortically, hypoperfusion was also found in the caudate nucleus. This pattern of hypoperfusion could be related to cognitive dysfunctions that have been previously observed even at the disease early stages. The present results were obtained by means of whole brain voxel-wise comparisons of absolute perfusion values, using statistical parametric mapping, thus avoiding the potentially biased global mean normalization procedure. In addition, this work demonstrates that between-group comparison of relative perfusion values after global mean normalization, introduced artifactual relative perfusion increases, where absolute perfusion was in fact preserved. This has implications for perfusion studies of other brain disorders.
Collapse
|